Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-4850

No board temperature for Mikrotik KNOT device

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Professional Edition
    • Discovery, Poller
    • None

    Description

      Board temperature not reading from Mikrotik KNOT device (RB924i-2nD-BT5&BG77).
      Read OID from Mikrotik System Health
      ```

      [admin@knot-mt] /system/health> print oid
       0 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.13 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.13 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.13

       1 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.7101 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.7101 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.7101

      ```
      data from smtpwalk
      ```
       snmpwalk -v2c -c public 10.0.180.254 .1.3.6.1.4.1.14988.1.1.3.100
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.13 = STRING: "voltage"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.7101 = STRING: "board-temperature1"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.13 = INTEGER: 513
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.7101 = INTEGER: 42
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.13 = INTEGER: 3
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.7101 = INTEGER: 1
      ```

      Attachments

        Activity

          [OBS-4850] No board temperature for Mikrotik KNOT device
          prezeskk Krzysztof Kulesza made changes -
          Comment [ After this change, the temperature appeared but the voltage information was doubled.
          Additionally, in other Mikrotik devices, information about both temperature and voltage has doubled. ]

          After this change, the temperature appeared but the voltage information was doubled.
          Additionally, in other Mikrotik devices, information about both temperature and voltage has doubled.

          prezeskk Krzysztof Kulesza added a comment - After this change, the temperature appeared but the voltage information was doubled. Additionally, in other Mikrotik devices, information about both temperature and voltage has doubled.
          prezeskk Krzysztof Kulesza made changes -
          Attachment New: Zrzut ekranu 2024-07-18 08.04.01.png [ 21375 ]
          prezeskk Krzysztof Kulesza made changes -
          Attachment New: Zrzut ekranu 2024-07-10 10.34.28.png [ 21374 ]
          landy Mike Stupalov made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: In Progress [ 3 ] New: Resolved [ 5 ]

          Added in r13587.

          landy Mike Stupalov added a comment - Added in r13587.
          landy Mike Stupalov made changes -
          Status Original: Pending Response [ 10000 ] New: In Progress [ 3 ]
          bot Observium Bot made changes -
          Status Original: Open [ 1 ] New: Pending Response [ 10000 ]
          prezeskk Krzysztof Kulesza created issue -

          General questions and device support can be discussed in our Discord channel, click here to join.


          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          • additionally attach device and/or vendor specific MIB files

          This comment is added automatically.

          bot Observium Bot added a comment - General questions and device support can be discussed in our Discord channel, click here to join . Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> additionally attach device and/or vendor specific MIB files This comment is added automatically.

          People

            landy Mike Stupalov
            prezeskk Krzysztof Kulesza
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: