Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-4850

No board temperature for Mikrotik KNOT device

    XMLWordPrintable

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Professional Edition
    • Discovery, Poller
    • None

    Description

      Board temperature not reading from Mikrotik KNOT device (RB924i-2nD-BT5&BG77).
      Read OID from Mikrotik System Health
      ```

      [admin@knot-mt] /system/health> print oid
       0 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.13 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.13 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.13

       1 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.7101 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.7101 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.7101

      ```
      data from smtpwalk
      ```
       snmpwalk -v2c -c public 10.0.180.254 .1.3.6.1.4.1.14988.1.1.3.100
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.13 = STRING: "voltage"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.7101 = STRING: "board-temperature1"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.13 = INTEGER: 513
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.7101 = INTEGER: 42
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.13 = INTEGER: 3
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.7101 = INTEGER: 1
      ```

      Attachments

        1. Zrzut ekranu 2024-07-18 08.04.01.png
          27 kB
          Krzysztof Kulesza
        2. Zrzut ekranu 2024-07-10 10.34.28.png
          31 kB
          Krzysztof Kulesza

        Activity

          People

            landy Mike Stupalov
            prezeskk Krzysztof Kulesza
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: