No board temperature for Mikrotik KNOT device

    XMLWordPrintable

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Professional Edition
    • Discovery, Poller
    • None

    Description

      Board temperature not reading from Mikrotik KNOT device (RB924i-2nD-BT5&BG77).
      Read OID from Mikrotik System Health
      ```

      [admin@knot-mt] /system/health> print oid
       0 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.13 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.13 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.13

       1 name=.1.3.6.1.4.1.14988.1.1.3.100.1.2.7101 value=.1.3.6.1.4.1.14988.1.1.3.100.1.3.7101 type=.1.3.6.1.4.1.14988.1.1.3.100.1.4.7101

      ```
      data from smtpwalk
      ```
       snmpwalk -v2c -c public 10.0.180.254 .1.3.6.1.4.1.14988.1.1.3.100
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.13 = STRING: "voltage"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.2.7101 = STRING: "board-temperature1"
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.13 = INTEGER: 513
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.3.7101 = INTEGER: 42
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.13 = INTEGER: 3
      SNMPv2-SMI::enterprises.14988.1.1.3.100.1.4.7101 = INTEGER: 1
      ```