Details
Description
A battery pre-failure is not detected by Observium at the moment.
Currently the battery status shows as following:
But the iLO shows a pre-failure:
and:
it seems that the pre-failure OID is not implemented in Observium.
The OID is .1.3.6.1.4.1.232.6.2.17.2.1.5.0.1 and value 15 (normal is 1) indicates a pre-failure.
The documentation about this check: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00026525en_us
Attachments
Activity
Status | Original: Resolved [ 5 ] | New: Closed [ 6 ] |
Attachment | New: image-2021-07-05-08-42-32-773.png [ 18819 ] |
Resolution | New: Fixed [ 1 ] | |
Status | Original: In Progress [ 3 ] | New: Resolved [ 5 ] |
Status | Original: In Review [ 10101 ] | New: In Progress [ 3 ] |
Status | Original: Pending Response [ 10000 ] | New: In Review [ 10101 ] |
Attachment | New: hpe-ilo4.snmpwalk [ 18810 ] |
Status | Original: Open [ 1 ] | New: Pending Response [ 10000 ] |
Thanks for fixing this issue! Works as expected: