HPe battery pre-failure error not monitored

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Professional Edition
    • Alerting, Discovery, Poller
    • None

    Description

      A battery pre-failure is not detected by Observium at the moment. 

      Currently the battery status shows as following:

      But the iLO shows a pre-failure:

      and:

      it seems that the pre-failure OID is not implemented in Observium.

      The OID is .1.3.6.1.4.1.232.6.2.17.2.1.5.0.1 and value 15 (normal is 1) indicates a pre-failure.

      The documentation about this check: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00026525en_us

      Attachments

        Activity

          [OBS-3799] HPe battery pre-failure error not monitored

          Thanks for fixing this issue! Works as expected:

          Schoemaker Quentin Schoemaker added a comment - Thanks for fixing this issue! Works as expected:

          Added in r11452.

          landy Mike Stupalov added a comment - Added in r11452.
          Schoemaker Quentin Schoemaker added a comment - - edited

          I added the result of the requested snmpwalk (of the affected server with degraded state).

          Schoemaker Quentin Schoemaker added a comment - - edited I added the result of the requested snmpwalk (of the affected server with degraded state).

          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk
            

            If device not support SNMP version 2c, replace -v2c with -v1.

          landy Mike Stupalov added a comment - Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1.