Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-3799

HPe battery pre-failure error not monitored

    XMLWordPrintable

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Professional Edition
    • Alerting, Discovery, Poller
    • None

    Description

      A battery pre-failure is not detected by Observium at the moment. 

      Currently the battery status shows as following:

      But the iLO shows a pre-failure:

      and:

      it seems that the pre-failure OID is not implemented in Observium.

      The OID is .1.3.6.1.4.1.232.6.2.17.2.1.5.0.1 and value 15 (normal is 1) indicates a pre-failure.

      The documentation about this check: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00026525en_us