Obsevium are showing values for the transceivers incorrectly on Cisco Catalyst 9500.
Correct values:
Temp: 26.2c
Volt: 3.30v
Current: 17.9mA
Transmit: -6.5dBm
Receive: -23.1dBm
Values from Observium is in my screenshot.
This error makes my alerts on the transceivers pretty useless, looking forward for this being resolved.
Attachments
Issue Links
- relates to
-
OBS-3707 Values wrong for transceivers on Cisco ASR
-
- Closed
-
Activity
Status | Original: Resolved [ 5 ] | New: Closed [ 6 ] |
Resolution | New: Fixed [ 1 ] | |
Status | Original: Pending Response [ 10000 ] | New: Resolved [ 5 ] |
Status | Original: In Review [ 10101 ] | New: Pending Response [ 10000 ] |
Attachment | New: interface_values_twe2-0-17.txt [ 16221 ] |
Attachment | New: dr11_debug_poller.txt [ 16220 ] |
Attachment | New: dr11_debug_discovery.txt [ 16219 ] |
Status | Original: Pending Response [ 10000 ] | New: In Review [ 10101 ] |
Attachment | New: interface_values.txt [ 16218 ] |
Issue Type | Original: Bug [ 1 ] | New: Vendor Bug [ 10000 ] |
Priority | Original: Major [ 3 ] | New: Trivial [ 5 ] |
Status | Original: Open [ 1 ] | New: Pending Response [ 10000 ] |