Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-3026

Wrong values for transceivers in Cisco 9500

    XMLWordPrintable

Details

    • Vendor Bug
    • Resolution: Fixed
    • Trivial
    • None
    • Professional Edition
    • Poller
    • Cisco C9500-48Y4C, C9500-24Y4C, C9500-32C

    Description

      Obsevium are showing values for the transceivers incorrectly on Cisco Catalyst 9500.

      Correct values:
      Temp: 26.2c
      Volt: 3.30v
      Current: 17.9mA
      Transmit: -6.5dBm
      Receive: -23.1dBm

      Values from Observium is in my screenshot.

      This error makes my alerts on the transceivers pretty useless, looking forward for this being resolved.

      Attachments

        1. transceiver-stats.png
          transceiver-stats.png
          9 kB
        2. interface_values.txt
          2 kB
        3. interface_values_twe2-0-17.txt
          2 kB
        4. dr11_debug_poller.txt
          17 kB
        5. dr11_debug_discovery.txt
          1.26 MB

        Issue Links

          Activity

            People

              landy Mike Stupalov
              bamsegrill Tommy Jonsson
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: