Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-2409

Raid battery failure not recognised in HP servers, reports controller status OK.

    XMLWordPrintable

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Community Edition
    • Poller
    • HP DL360 Gen 5 and Gen 6, Centos 7, hp-snmp-agents, hp-health.

    Description

      Observium does not give any info about controller batteries, which may be dead even if controller status is ok.

      Observium:

      Smart Array P400i (Slot 0) Status ok

      HP ssacli:

      => ctrl all show status

      Smart Array P400i in Slot 0 (Embedded)
      Controller Status: OK
      Cache Status: Temporarily Disabled
      Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)

       

      Attachments

        1. status1.jpg
          status1.jpg
          116 kB
        2. status2.jpg
          status2.jpg
          81 kB
        3. status3.jpg
          status3.jpg
          68 kB
        4. status4.jpg
          status4.jpg
          25 kB

        Activity

          People

            adama Adam Armstrong
            leo Leo Koivulehto
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: