Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-2409

Raid battery failure not recognised in HP servers, reports controller status OK.

    XMLWordPrintable

Details

    • Improvement
    • Resolution: Fixed
    • Minor
    • None
    • Community Edition
    • Poller
    • HP DL360 Gen 5 and Gen 6, Centos 7, hp-snmp-agents, hp-health.

    Description

      Observium does not give any info about controller batteries, which may be dead even if controller status is ok.

      Observium:

      Smart Array P400i (Slot 0) Status ok

      HP ssacli:

      => ctrl all show status

      Smart Array P400i in Slot 0 (Embedded)
      Controller Status: OK
      Cache Status: Temporarily Disabled
      Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)

       

      Attachments

        1. status4.jpg
          25 kB
          Leo Koivulehto
        2. status1.jpg
          116 kB
          Leo Koivulehto
        3. status2.jpg
          81 kB
          Leo Koivulehto
        4. status3.jpg
          68 kB
          Leo Koivulehto

        Activity

          People

            adama Adam Armstrong
            leo Leo Koivulehto
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: