Description
100G and 400G ZR Optics duplication of due to discovery in two MIBs.
Some background:
We recently have had open a ticket with Juniper Support regarding this,
with optics like :
Media Code : 100GBASE-ZR (Clause 154)
Media Code : ZR-400-OFEC-16QAM
We reported to juniper that values, such as 'TX Bias' from the JUNIPER-IFOPTICS-MIB does not return a value, but Observium is able to retrieve the thresholds.
After some further investigation and back and forth on the ticket Juniper has confirmed to us that JUNIPER-IFOPTICS-MIB is supposedly not supported on the PTX device we have and we should instead be using the JUNIPER-DOM-MIB.
However the problem we current see is as such, take example et-0/1/2 Interface,
We have 2xTX-Bias entries, one from each mib as above.
JUNIPER-IFOPTICS-MIBjnxPMCurTxLaserBiasCurrent517, reports a value 0.22A perfect, but doesn't have any thresholds listed, just infinity symbol.
JUNIPER-DOM-MIBjnxDomCurrentTxLaserBiasCurrent517,, doesn't report a value, just 0A, but does report a threshold.
To me it looks like Observium almost needs to be aware of ZR optic's having lanes and instead make sure it's using
jnxDomCurrentLaneTxLaserBiasCurrent 0.001 mAInteger32 .1.3.6.1.4.1.2636.3.60.1.2.1.1.7
Rather than what it's currently using:
jnxDomCurrentTxLaserBiasCurrent 0.001 mAInteger32 .1.3.6.1.4.1.2636.3.60.1.1.1.1.6
PIC Information, Optics impacted by this issue is 2,3,6,8,9,10,11. This is on fpc-slot 0, pic-slot 1.
PIC port information:
Fiber Xcvr vendor Wave- Xcvr JNPR MSA
Port Cable type type Xcvr vendor part number length Firmware Rev Version
0 400G-AOC 3M MM JUNIPER-2H3 740-090165 850 nm 1.3 REV 01 CMIS 3.0
1 400G-AOC 3M MM JUNIPER-2H3 740-090165 850 nm 1.3 REV 01 CMIS 3.0
2 400G-ZR-M SM JUNIPER-2E1 740-157138 1528.77 nm - 1567.13 nm 1.3 REV 01 CMIS 5.1
3 400G-ZR-M SM JUNIPER-2E1 740-157138 1528.77 nm - 1567.13 nm 1.3 REV 01 CMIS 5.1
6 4X10GBASE LR SM JUNIPER-INNO TR-IQ13L-NJ4 1307.5 nm 0.0 REV 02 SFF-8636 ver 2.7
8 400G-ZR-M SM JUNIPER-2E1 740-157138 1528.77 nm - 1567.13 nm 1.3 REV 01 CMIS 5.1
9 400G-ZR-M SM JUNIPER-2E1 740-157138 1528.77 nm - 1567.13 nm 1.3 REV 01 CMIS 5.1
10 400G-LR4-10KM SM JUNIPER-1G2 740-096176 1301 nm 0.15 REV 01 CMIS 5.0
11 100G-ZR SM JUNIPER-1A1 740-172665 1528.77 nm - 1567.13 nm 2.6 REV 01 CMIS 5.2
Observium Version:Observium 26.4.14752 (rolling) (21st April 2026)
The main one to fix is TX Bias, since RX Power and TX Power is ok from the JUNIPER-DOM-MIB currently, but it would be nice to be able to still have the JUNIPER-IFOPTICS-MIB enabled to still keep the data for Carrier Frequency Offset, OSNR and SNR, which seems ok, but then hide the duplicate entries we have from IFOPTICS-MIB for RX power and Tx power.
Then also hiding DOM and Voltage sensors, since both are working ok for both thresholds and values currently.
I've attached the walk of the MIB in question, screenshot of an example of one port et-0/1/2 with snmpIndex 517.
Regards,
Luke.