Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-4941

Issue with cisco nexus/fex interface counters

Details

    • Vendor Bug
    • Resolution: Won't Fix
    • Major
    • None
    • Professional Edition
    • Graphs
    • None

    Description

      Hello

       

      For some reason observium doesn’t display graphs for some interfaces in cisco nexus devices.

      I can see everything up to Ethernet110/1/48 and nothing after that in observium. But in other monitoring software there is no such issue.

      I have some phantom FEX interfaces 114/1/1-48, 164/1/1-164/1/32, 198/1/1-198/1/16 and 199/1/1-199/1/16 that I cannot get rid of.

      It seems that the problem starts from from where the phantom interfaces first start (Eth114/1/1), but I am not sure if these have anything to do with it.

      Could you please help me with this issue?
      Please see the screenshots and files also

      Attachments

        1. nexus1 output.txt
          64 kB
        2. nexus1 poller partial output.txt
          103 kB
        3. nexus2 output.txt
          63 kB
        4. nexus2 poller partial output.txt
          101 kB
        5. proof.PNG
          proof.PNG
          279 kB
        6. proof2.PNG
          proof2.PNG
          281 kB

        Activity

          People

            landy Mike Stupalov
            kaupo@wavecom.ee Kaupo Ehtnurm
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: