      Observium natively supports the Alpha FXM 650, however those devices are EOL, and the replacement is the Alpha FXM HP. Here are the mib files from the new system, as well as an SNMP dump file. Thanks!

      Attachments

        Activity

          [OBS-4357] Alpha FXM HP Support

          It does appear it's pulling the wrong value for the input voltage. It should be the same or similar to the output voltage. 

          HamSolo Elijah Zeida added a comment - It does appear it's pulling the wrong value for the input voltage. It should be the same or similar to the output voltage. 

          This is how the old ones look

          And this is how the new ones look now, much improved! Thank you!

          HamSolo Elijah Zeida added a comment - This is how the old ones look And this is how the new ones look now, much improved! Thank you!

          Improved in r12455.

          landy Mike Stupalov added a comment - Improved in r12455.

          It will very good if you also attach snmpdump for FXM 650.

          landy Mike Stupalov added a comment - It will very good if you also attach snmpdump for FXM 650.

          Just for sure, show please how Alpha FXM 650 currently detected (screenshot of device overview).

          landy Mike Stupalov added a comment - Just for sure, show please how Alpha FXM 650 currently detected (screenshot of device overview).

          General questions and device support can be discussed in our Discord channel, click here to join.


          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          • additionally attach device and/or vendor specific MIB files

          This comment is added automatically.

          bot Observium Bot added a comment - General questions and device support can be discussed in our Discord channel, click here to join . Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> additionally attach device and/or vendor specific MIB files This comment is added automatically.