Details

    Description

      Hi,

      We need support for Delta UPS DPH500, we attach MIBS and snmp dumps for this model.

       

      Thanks!

      Attachments

        1. dbms511.mib
          18 kB
          Sistemas NIXVAL
        2. discovery.dump
          65 kB
          Sistemas NIXVAL
        3. EMS1000V2.mib
          20 kB
          Sistemas NIXVAL
        4. myagent.snmpwalk
          15 kB
          Sistemas NIXVAL
        5. poller.dump
          77 kB
          Sistemas NIXVAL
        6. UPSv5.mib
          89 kB
          Sistemas NIXVAL

        Activity

          [OBS-3358] Support UPS DELTA DPH500

          Hi Sistemas NIXVAL, we have not received the additional information requested earlier from you in this issue 'Hi,

          We need support for Delta UPS DPH500, we attach MIBS and snmp dumps for this model.

           

          Thanks!'!

          Issues without your response will be closed within 2 weeks.

          landy Mike Stupalov added a comment - Hi Sistemas NIXVAL, we have not received the additional information requested earlier from you in this issue 'Hi, We need support for Delta UPS DPH500, we attach MIBS and snmp dumps for this model.   Thanks!'! Issues without your response will be closed within 2 weeks.

          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          • additionally attach device and/or vendor specific MIB files

          Note, this comment is added automatically.

          bot Observium Bot added a comment - Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> additionally attach device and/or vendor specific MIB files Note, this comment is added automatically.

          People

            landy Mike Stupalov
            nixval Sistemas NIXVAL
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated: