Description
would be possible to collect the measurement in dBm dell powerconnect switches ? Today this feature is already available in observium in cisco routers .
in command line this command is:
RS - BKB - GVR - 001 - SW- 001 # show ports Fiber - optical- transceiver
Input output
Port Temp Voltage Current Power Power TX LOS
[ C ] [ Volt ] [ mA ] [ dBm ] [ dBm ] Fault
-----------------------------------------------
1/g48 31.5 3,348 29.8 -4,711 -8,918 No No
1/xg1 39.4 3,301 31.5 3,418 -19,508 No No
1/xg2 47.6 3,277 37.3 1,838 -18,239 No No
Temp - Internally Measured temperatures transceiver .
Voltage - Internally Measured supply voltage .
Current - Measured TX bias current.
Output Power - Measured optical output power relative to 1mW .
Input Power - Measured optical power received relative to 1mW .
TX Fault - Transmitter fault .
LOS - Loss of signal .
RS- GVR - BKB -001 -001 -SW #