Details
-
Improvement
-
Resolution: Fixed
-
Minor
-
None
-
None
Description
Summary
Improvements for FS.com switches running FSOS NG (fsos-ng): PoE (per unit and per port), VSU stack health, per-unit naming of fans, PSUs and temperatures in stacks, bogus DOM sensors removed on DAC cables, and a fix for LLDP walks aborting with "OID not increasing".
Patch: 05-fscom-fsos-ng.patch (attached). Apply from the Observium root with patch -p1 < 05-fscom-fsos-ng.patch. It was built against trunk SVN BASE and applies cleanly. FS-POE-MIB and FS-VSU-MIB already ship with Observium.
What it adds / fixes
- PoE per unit: "Unit N PoE" budget/consumption power and operational status, from POWER-ETHERNET-MIB pethMainPse* (index = stack unit).
- PoE per port:
- Consumed power from FS-POE-MIB ifPoeConsumingPwr (mW, index = ifIndex).
- Status from pethPsePortDetectionStatus. Its index is unit*100 + port, matched to ports through ifDescr U/0/P. Value 0
is skipped, and fault is a warning.
- VSU stack health (FS-VSU-MIB): topology shape (ring/chain), member device status and role, and VSL port state.
- Per-unit naming: FS-SYSTEM fan, PSU and temperature descriptions are now "Unit N ...", so entries in a stack are no longer ambiguous.
- Fan speed: fsSystemFanStatusSpeed gets min = 0. The S3410 always reports 0 rpm, so only fan status is meaningful there.
- DAC/copper modules: every FS-FIBER-MIB DOM sensor now checks fsFiberTransceiverType notmatch Copper. 10G DAC stack cables reported garbage DDM values (6.553 V, 0.131 A) that created bogus sensors.
- LLDP "OID not increasing": the FSOS NG agent sometimes returns a non-increasing OID while walking a large LLDP neighbour table. net-snmp then aborts the whole bulkwalk, causing partial LLDP data and eventlog warnings on every column. $config['os']['fsos-ng']['snmp']['noincrease'] = TRUE adds -Cc, exactly as the warning suggests. Bulk performance is kept, unlike disabling bulk.
Files
| File | Status | Purpose |
|---|---|---|
| includes/definitions/mibs/fscom.inc.php | changed | "Unit N" descriptions, fan min 0, FS-POE-MIB states, FS-VSU-MIB status definitions |
| includes/definitions/mibs/fscom/fs-fiber-mib.inc.php | changed | Skip DOM sensors on copper/DAC modules |
| includes/definitions/os/fscom.inc.php | changed | fsos-ng: FS-POE-MIB, FS-VSU-MIB, snmp noincrease |
| includes/discovery/sensors/fs-poe-mib.inc.php | new | PoE per unit and per port (power and status) |
Notes for maintainers
- Generic POWER-ETHERNET-MIB is not enabled for fsos-ng: its port index (unit*100+port) doesn't map to ifIndex, so values would land on the wrong ports.
- Per-port PoE limits. When the port has no configured maximum (ifPoeMaxPwrSet unset, 2147483647), the discovery sets fixed limits of warn 12 W / alert 15.4 W (802.3af class 0). Otherwise Observium's automatic limit (value x 1.5) alerts constantly on low-draw devices (a 1.5 W phone gets a 2.25 W limit). If you prefer, these could become config options.
Testing
- S3410-48TS-P, FSOS 11.4, three-unit VSU ring.
- LLDP: -Cc confirmed in the actual snmpbulkwalk command; full neighbour table returned and no new eventlog warnings.
- php -l clean.