F5 rSeries - Temperature off by a factor of 10

    XMLWordPrintable

Details

    • Bug
    • Resolution: Fixed
    • Minor
    • None
    • None
    • Default
    • F5OS 1.8.0

    Description

      Hi
      There are some updates to F5 loadbalancer mibs for the rSeries.
      There are some additions, but more importantly, a change in display type for platform temperature stats which sets the temperature off by a factor of 10.
      This changed between F5OS 1.7.0 and 1.8.0.

      Attached are:
      New mibs
      Snmp dump of the f5PlatformStats OID's (can't supply a complete dump unfortunately)
      Temperature graph

      If possible to fix with the supplied information, it would be great. Thx!