Details

    • Add New Device / OS
    • Resolution: Fixed
    • Minor
    • None
    • Enterprise Edition
    • OS
    • None
    • Ubuntu 22.04.4 LTS

    Description

      I wanted to request adding support for Exagrid tiered backup storage appliances to observium.

      <Links and mentions to this project completely prohibited>

      And here is an SNMPwalk - 

      .1.3.6.1.4.1.14941.4.1.1.0 = Gauge32: 20208
      .1.3.6.1.4.1.14941.4.1.2.0 = Gauge32: 392000000
      .1.3.6.1.4.1.14941.4.1.3.0 = Gauge32: 13016
      .1.3.6.1.4.1.14941.4.1.4.0 = Gauge32: 572533198
      .1.3.6.1.4.1.14941.4.2.1.0 = Gauge32: 57516
      .1.3.6.1.4.1.14941.4.2.2.0 = Gauge32: 193000000
      .1.3.6.1.4.1.14941.4.2.3.0 = Gauge32: 15772
      .1.3.6.1.4.1.14941.4.2.4.0 = Gauge32: 751691496
      .1.3.6.1.4.1.14941.4.2.5.0 = Gauge32: 36629
      .1.3.6.1.4.1.14941.4.2.6.0 = Gauge32: 157953988
      .1.3.6.1.4.1.14941.4.2.7.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.2.8.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.2.9.0 = Gauge32: 5114
      .1.3.6.1.4.1.14941.4.2.10.0 = Gauge32: 283354516
      .1.3.6.1.4.1.14941.4.2.11.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.2.12.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.2.13.0 = Gauge32: 5114
      .1.3.6.1.4.1.14941.4.2.14.0 = Gauge32: 283354516
      .1.3.6.1.4.1.14941.4.3.1.0 = Gauge32: 267370
      .1.3.6.1.4.1.14941.4.3.2.0 = Gauge32: 653720796
      .1.3.6.1.4.1.14941.4.3.3.0 = Gauge32: 36629
      .1.3.6.1.4.1.14941.4.3.4.0 = Gauge32: 157953988
      .1.3.6.1.4.1.14941.4.4.1.0 = Gauge32: 47
      .1.3.6.1.4.1.14941.4.4.2.0 = Gauge32: 359459328
      .1.3.6.1.4.1.14941.4.4.3.0 = 4797035
      .1.3.6.1.4.1.14941.4.5.1.0 = Gauge32: 254
      .1.3.6.1.4.1.14941.4.5.2.0 = Gauge32: 896142070
      .1.3.6.1.4.1.14941.4.5.3.0 = 47036294
      .1.3.6.1.4.1.14941.4.6.1.0 = INTEGER: 2
      .1.3.6.1.4.1.14941.4.7.1.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.7.2.0 = Gauge32: 0
      .1.3.6.1.4.1.14941.4.7.3.0 = Gauge32: 144
      .1.3.6.1.4.1.14941.4.7.3.0 = No more variables left in this MIB View (It is past the end of the MIB tree)

      Let me know if you need anything further. Thanks for your consideration.

      Attachments

        Activity

          [OBS-4811] Exagrid Device Support
          cblair Corey added a comment -

          MIB from Vendor attached. Thanks for looking at this.

          cblair Corey added a comment - MIB from Vendor attached. Thanks for looking at this.

          Basic support added in r13494.

          MIB unusable for this firmware, need latest from vendor.

          landy Mike Stupalov added a comment - Basic support added in r13494. MIB unusable for this firmware, need latest from vendor.

          General questions and device support can be discussed in our Discord channel, click here to join.


          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          • additionally attach device and/or vendor specific MIB files

          This comment is added automatically.

          bot Observium Bot added a comment - General questions and device support can be discussed in our Discord channel, click here to join . Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> -t 3 -Cc --hexOutputLength=0 -Ih -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> additionally attach device and/or vendor specific MIB files This comment is added automatically.

          People

            landy Mike Stupalov
            cblair Corey
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: