Cant see the hardware type for Fortinet devices in newer versions

Details

    • Improvement
    • Resolution: Fixed
    • Major
    • None
    • None
    • Default
    • None

    Description

      I cant see the fgmodel mib at observium

      The hardware showing empty

      The observium version is 

      22.8.12250 (16th August 2022)

      Attachments

        Activity

          [OBS-4227] Cant see the hardware type for Fortinet devices in newer versions
          Shama Tarek added a comment -

          Great

          It looks better now

          Thank you for help !!

          Shama Tarek added a comment - Great It looks better now Thank you for help !!

          Improved in r12265.

          landy Mike Stupalov added a comment - Improved in r12265.
          landy Mike Stupalov added a comment - - edited

          I need to see extra information about device.
          Please attach as minimum debug for poller:

          ./poller.php -d -h <device>
          

          landy Mike Stupalov added a comment - - edited I need to see extra information about device. Please attach as minimum debug for poller: ./poller.php -d -h <device>
          Shama Tarek added a comment -

          Did you have a chance to look into it?

          Shama Tarek added a comment - Did you have a chance to look into it?
          Shama Tarek added a comment -

          Its taking ages to collect these files, i started with the first one, it had more than 319K rows, i had to stop it

          If you can send me the exact mib for the hardware that its showing empty when running the poller that would be great.

          I looked at https://mibs.observium.org/mib/FORTINET-FORTIGATE-MIB/ and i dont see the model that we are using which is 1800F, maybe that is the problem? 

           

          Shama Tarek added a comment - Its taking ages to collect these files, i started with the first one, it had more than 319K rows, i had to stop it If you can send me the exact mib for the hardware that its showing empty when running the poller that would be great. I looked at https://mibs.observium.org/mib/FORTINET-FORTIGATE-MIB/ and i dont see the model that we are using which is 1800F, maybe that is the problem?   

          It's unknown issue.

          Please attach information requested by Observium Bot above.