Details
-
Bug
-
Resolution: Fixed
-
Trivial
-
None
-
Enterprise Edition
-
None
Description
Observium uses the wrong MIB for fan speed on 'Aruba JL676A 6100 48G 4SFP+ Swch PL.10.09.0002' with ArubaOS-CX.
Instead of 'ENTITY-SENSOR-MIB' you should use 'ARUBAWIRED-FAN-MIB::arubaWiredFanRPM' if a fan is present.
Attachments
Activity
Resolution | New: Fixed [ 1 ] | |
Status | Original: Pending Response [ 10000 ] | New: Resolved [ 5 ] |
Status | Original: Open [ 1 ] | New: Pending Response [ 10000 ] |
Already was fixed long time ago in r11696.