Details
-
Bug
-
Resolution: Fixed
-
Minor
-
None
-
Professional Edition
-
None
Description
Hi there,
after migrating to latest version, we noticed that devices with multiple VRFs are generating eventlog every hours that VRF has been added/updated. The eventlog is full of entries like this.
2020-12-02 11:55:52 pop13-asr VRF: 7 updated.
2020-12-02 11:06:46 pop13-asr VRF: 7 updated.
2020-12-02 09:28:40 pop13-asr VRF: 6 added, 1 updated.
2020-12-02 03:46:13 pop13-asr VRF: 6 added, 1 updated.
2020-12-01 20:57:22 pop13-asr VRF: 6 added, 1 updated.
2020-12-01 14:54:03 pop13-asr VRF: 7 added.
2020-12-01 09:04:16 pop13-asr VRF: 6 added, 1 updated.
2020-12-01 04:30:38 pop13-asr VRF: 6 added, 1 updated.
2020-11-30 21:58:05 pop13-asr VRF: 6 added, 1 updated.
Attached I uploaded two discovery debugs. The first was made at 2020-12-02 11:06:46 the second at 2020-12-02 11:55:52. Last one produced antoher eventlog. Maybe you can see something was changed and what caused this log entry?
Attachments
Issue Links
- is mentioned by
-
OBS-3600 Duplicate VRF entries
- Closed