Description
Adding an ICT Platinum DC Power device, looks like its missing the correct MIB translations. It categorizes it correctly as a power device but doesn't discovery any of the important power status. I know this is a newer device model. See attached Vendor MIB file.
Attachments
Issue Links
- relates to
-
OBS-3925 ICT Power Systems MIB
-
- Closed
-
Looks like adding the .0 provides results.
[root@obs observium]# snmpwalk -v2c -c sw-core-snmp1 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/ict 10.50.112.254 ICT-PLATINUM-SERIES-MIB::batteryTemperature
ICT-PLATINUM-SERIES-MIB::batteryTemperature = No Such Object available on this agent at this OID
[root@obs observium]# snmpwalk -v2c -c sw-core-snmp1 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/ict 10.50.112.254 ICT-PLATINUM-SERIES-MIB::batteryTemperature.0
ICT-PLATINUM-SERIES-MIB::batteryTemperature.0 = INTEGER: 1000