    Description

      Please add support for DDM on Eltex MES Switches.

      Software on MES23xx\33xx the same, may be will work for more models, doesn't have to test.

       

      DDM information stores at .1.3.6.1.4.1.89.90.1.2 (RADLAN-PHY MIB)

       

       

       

       

      Attachments

        Activity

          [OBS-3326] Eltex MES 23xx 33xx DDM

          RX Power - Wrong Multiplier?

          TX Power have valid 1/1000

          RX Power have 1/1000000

           

          goletsa Alexey Golets added a comment - RX Power - Wrong Multiplier? TX Power have valid 1/1000 RX Power have 1/1000000  

          Support added in r10406.

          landy Mike Stupalov added a comment - Support added in r10406.

          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          • additionally attach device and/or vendor specific MIB files

          Note, this comment is added automatically.

          landy Mike Stupalov added a comment - Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> additionally attach device and/or vendor specific MIB files Note, this comment is added automatically.