Details
-
Improvement
-
Resolution: Fixed
-
Trivial
-
None
-
Professional Edition
-
None
Description
in includes/discovery/sensors/cpqhlth-mib.inc.php
The powersupply info for HP-server is add, but some when you have some powersupplys they don't provide all info:
CPQHLTH-MIB::cpqHeFltTolPowerSupplyPresent.1.1 = INTEGER: present(3)
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyCondition.1.1 = INTEGER: ok(2)
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyStatus.1.1 = INTEGER: noError(1)
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyMainVoltage.1.1 = INTEGER: 0
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyCapacityUsed.1.1 = INTEGER: 0
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyCapacityMaximum.1.1 = INTEGER: 0
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyRedundant.1.1 = INTEGER: notRedundant(2)
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyModel.1.1 = STRING: " "
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplySerialNumber.1.1 = STRING: " "
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyAutoRev.1.1 = Hex-STRING: 00 00 00 00
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyHotPlug.1.1 = INTEGER: nonHotPluggable(2)
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyFirmwareRev.1.1 = ""
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplySparePartNum.1.1 = STRING: " "
|
CPQHLTH-MIB::cpqHeFltTolPowerSupplyErrorCondition.1.1 = INTEGER: noError(1)
|
"cpqHeFltTolPowerSupplyStatus" and "cpqHeFltTolPowerSupplyMainVoltage" should also be polled.