Uploaded image for project: 'Observium'
  1. Observium
  2. OBS-3242

Fortigate 1500D wrong classification of power supply

Details

    • Improvement
    • Resolution: Fixed
    • Major
    • None
    • Professional Edition
    • None
    • None

    Description

      On all of my Fortigate 1500D's the SNMP information regarding the power supply are all under temperature:

      Can you please move the following MIB's to these categories?

      Fanspeed:
      PS1 Fan 1 FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.42
      PS2 Fan 1 FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.47

      Voltage:
      PS1 VIN FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.43
      PS2 VIN FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.48

      Status:
      PS1 Status FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.45
      PS2 Status FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.50

      I dont know where to put:
      INA219 PS1 Vsht FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.51
      INA219 PS1 Vbus FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.52
      INA219 PS2 Vsht FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.53
      INA219 PS2 Vbus FORTINET-FORTIGATE-MIB::fgHwSensorEntValue.54
       

      Attachments

        Activity

          [OBS-3242] Fortigate 1500D wrong classification of power supply

          Fixed in r10298.

          landy Mike Stupalov added a comment - Fixed in r10298.
          cliff.ha Mark added a comment -

          I have attached the requested snmpwalk.
          myagent.snmpwalk

          cliff.ha Mark added a comment - I have attached the requested snmpwalk. myagent.snmpwalk

          Please make and attach additional information about the device:

          • full snmp dump from device:

            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk
            snmpwalk -v2c -c <community>  --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk

            If device not support SNMP version 2c, replace -v2c with -v1.

          • If you have problems with discovery or poller processes, please do and attach these debugs:

            ./discovery.php -d -h <device>
            ./poller.php -d -h <device>

          Note, this comment is added automatically.

          landy Mike Stupalov added a comment - Please make and attach additional information about the device: full snmp dump from device: snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1 > myagent.snmpwalk snmpwalk -v2c -c <community> --hexOutputLength=0 -ObentxU <hostname> .1.3.6.1.4.1 >> myagent.snmpwalk If device not support SNMP version 2c, replace -v2c with -v1. If you have problems with discovery or poller processes, please do and attach these debugs: ./discovery.php -d -h <device> ./poller.php -d -h <device> Note, this comment is added automatically.

          People

            landy Mike Stupalov
            cliff.ha Mark
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: