    Description

      Is there somehow possible to improve the support of matching the health values to the breakout’ed ports?

      We have some 1x40G (-> 4x10G breakout) optics in use and would like to get the dBm, ampere etc values to port specific port matched. In this example to TenGigE0/0/0/34/1.

      Attached I have a full debug output for a device which contains this sort of optics.

      Example Port: TenGigE0/0/0/34/1 which is a daughter port of FortyGigE0/0/0/34

      Attachments

        Activity

          [OBS-2823] Improve breakout transceivers support
          landy Mike Stupalov made changes -
          Status Original: Resolved [ 5 ] New: Closed [ 6 ]
          landy Mike Stupalov made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: In Progress [ 3 ] New: Resolved [ 5 ]
          landy Mike Stupalov made changes -
          Status Original: Pending Response [ 10000 ] New: In Progress [ 3 ]
          landy Mike Stupalov made changes -
          Status Original: Open [ 1 ] New: Pending Response [ 10000 ]
          dklimek Denis Klimek created issue -