Hi there,
After upgrading to latest IOS-XR 7.x release we've noticed that all transceivers are not linked to their physical interface anymore. Looks like that Cisco changed something or even broke it, but I can not see what have been changed. I tried to upload snmpwalk, but even compressed it's about 140MB.
But this is Cisco error than..
Discover sensor: [class: voltage, device: asr-heidbergstrasse-gk, oid: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.3113200, index: 3113200, type: CISCO-ENTITY-SENSOR-MIB-entSensorValue, descr: unsupported module - Voltage - TenGigE0/0/0/32-3.3 V, scale: 0.001, limits: (3.08, 3.1, 3.48, 3.5), CURRENT: 0, 3113200,entSensorType.3113200 = voltsDCentSensorScale.3113200 = unitsentSensorPrecision.3113200 = 3entSensorValue.3113200 = 0^^^entSensorStatus.3113200 = okentSensorValueTimeStamp.3113200 = 0:0:00:00.00entSensorValueUpdateRate.3113200 = 10entSensorMeasuredEntity.3113200 = 3112961entSensorThresholdSeverity.3113200.1 = minorentSensorThresholdSeverity.3113200.2 = minorentSensorThresholdSeverity.3113200.3 = majorentSensorThresholdSeverity.3113200.4 = majorentSensorThresholdSeverity.3113200.5 = criticalentSensorThresholdSeverity.3113200.6 = criticalentSensorThresholdRelation.3113200.1 = lessOrEqualentSensorThresholdRelation.3113200.2 = greaterOrEqualentSensorThresholdRelation.3113200.3 = lessOrEqualentSensorThresholdRelation.3113200.4 = greaterOrEqualentSensorThresholdRelation.3113200.5 = lessOrEqualentSensorThresholdRelation.3113200.6 = greaterOrEqualentSensorThresholdValue.3113200.1 = 0entSensorThresholdValue.3113200.2 = 0entSensorThresholdValue.3113200.3 = 3100entSensorThresholdValue.3113200.4 = 3480entSensorThresholdValue.3113200.5 = 3080entSensorThresholdValue.3113200.6 = 3500