    Description

      I'am not very sure but I think there is a problem if the sensor_value / measured value is "0" in snmp reply for custom alerts. We have a lot of false positive since months which we simply ignored until today but now we would like to fix this.

      I have an alert that checks the RX power light level and triggers an alert if the sensor_value is below sensor_limit_low. That's working so far fine, but if the device replys with an INTEGER of 0 I'am not able to match it. The alert still gets triggered in this case which shouldn't.

      I also added a screenshot of the alert, the current database output, test conditions used in checker and a snmpget for the specific OID.

       

       

      sensor_value le @sensor_limit_low
      sensor_value ne 0.00000
      sensor_value ne 0
      sensor_value ne -40.00000
      sensor_value ne -30.00000
      

       

       

      {
      	"table": "sensors",
      	"rows":
      	[
      		{
      			"sensor_id": 48785,
      			"sensor_deleted": 0,
      			"sensor_class": "dbm",
      			"device_id": 52,
      			"poller_type": "snmp",
      			"sensor_oid": ".1.3.6.1.4.1.9.9.91.1.1.1.1.4.46010283",
      			"sensor_mib": "CISCO-ENTITY-SENSOR-MIB",
      			"sensor_object": "entSensorValue",
      			"sensor_index": "46010283",
      			"sensor_type": "CISCO-ENTITY-SENSOR-MIB-entSensorValue",
      			"sensor_descr": "Non-Cisco OEM SFP+ 10G Pluggable Optics Module - Transceiver Rx Power - Rx 0/0/2/1",
      			"sensor_unit": "W",
      			"sensor_multiplier": 0.000001,
      			"sensor_limit": 0,
      			"sensor_limit_warn": -1.00179,
      			"sensor_limit_low": -15.5284,
      			"sensor_limit_low_warn": -14.437,
      			"sensor_custom_limit": 0,
      			"entPhysicalIndex_measured": "36",
      			"measured_class": "port",
      			"measured_entity": "6010",
      			"entPhysicalIndex": "46010283",
      			"entPhysicalClass": null,
      			"sensor_ignore": 0,
      			"sensor_disable": 0,
      			"sensor_value": 0.00000,
      			"sensor_event": "alert",
      			"sensor_status": "Sensor critical thresholds exceeded.",
      			"sensor_polled": 1579166206,
      			"sensor_last_change": 1563878252
      		}
      	]
      }

       

       

       

      root@observium:/opt/observium# snmpget -c XXX -v 2c asr .1.3.6.1.4.1.9.9.91.1.1.1.1.4.46010283
      iso.3.6.1.4.1.9.9.91.1.1.1.1.4.46010283 = INTEGER: 0
      

       

       

      Attachments

        Activity

          [OBS-3200] False-Positive, Meassured value missing if it is "0"
          landy Mike Stupalov made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: Reopened [ 4 ] New: Closed [ 6 ]
          landy Mike Stupalov made changes -
          Attachment Original: poller-debug.txt [ 16940 ]
          landy Mike Stupalov made changes -
          Resolution Original: Fixed [ 1 ]
          Status Original: Closed [ 6 ] New: Reopened [ 4 ]
          landy Mike Stupalov made changes -
          Status Original: Resolved [ 5 ] New: Closed [ 6 ]

          It works

          dklimek Denis Klimek added a comment - It works

          r10238 now should fix issue.

          landy Mike Stupalov added a comment - r10238 now should fix issue.

          derp... scale..

          landy Mike Stupalov added a comment - derp... scale..

          Hmm I think it's not working.

          In discovery debug I still see this:

          DOM power sensor forced to dBm sensor.
          Converted DBM value: -0.009999 W -> FALSE

          Can you check? This time I uploaded a poller debug for the sensors.

          dklimek Denis Klimek added a comment - Hmm I think it's not working. In discovery debug I still see this: DOM power sensor forced to dBm sensor. Converted DBM value: -0.009999 W -> FALSE Can you check? This time I uploaded a poller debug for the sensors.
          dklimek Denis Klimek made changes -
          Attachment New: poller-debug.txt [ 16940 ]

          Added conversion exclude (-9999W to -99dBm) in r10236.

          landy Mike Stupalov added a comment - Added conversion exclude (-9999W to -99dBm) in r10236.