Details

    • Bug
    • Resolution: Fixed
    • Minor
    • None
    • None
    • None
    • None

    Description

      OBS-3073 was opened for WTI VMR support.  I'm still not seeing any power related information however.  Can you take a look at this again?

       

      Attachments

        1. devices.png
          devices.png
          89 kB
        2. mib.zip
          8 kB
        3. watchdog_discovery.txt
          46 kB
        4. wti01_discovery.txt
          68 kB
        5. wti01_poller.txt
          17 kB
        6. wti02_discovery.txt
          75 kB
        7. wti02_poller.txt
          17 kB

        Issue Links

          Activity

            [OBS-3141] WTI VMR series - no power info

            ok, additionally for devices with DCN logo, attach poller debug as:

            ./poller.php -d -r -m os,system -h <device>

            landy Mike Stupalov added a comment - ok, additionally for devices with DCN logo, attach poller debug as: ./poller.php -d -r -m os,system -h <device>
            derek.sedik@nextlevel.net Next Level added a comment - - edited

            Device page and Watchdog discovery attached.  Also attached a different MIB for the Watchdog.

             

             

            derek.sedik@nextlevel.net Next Level added a comment - - edited Device page and Watchdog discovery attached.  Also attached a different MIB for the Watchdog.    

            WTI image logo is something called "DCN"
            Show screenshot from device page

            WTI has no ethernet port, but the power sensors are there and working
            this not possible to fix in our side, device not report any ports Oids (there is should used common IF-MIB).

            Geist has ethernet port but no sensors
            attach debug (with -d) discovery for this device:

            ./discovery.php -d -h <device>

            landy Mike Stupalov added a comment - WTI image logo is something called "DCN" Show screenshot from device page WTI has no ethernet port, but the power sensors are there and working this not possible to fix in our side, device not report any ports Oids (there is should used common IF-MIB). Geist has ethernet port but no sensors attach debug (with -d) discovery for this device: ./discovery.php -d -h <device>
            derek.sedik@nextlevel.net Next Level added a comment -

            The diff issue is resolved.

            ubuntu@nms01:/opt/observium$ sudo svn status
            D mibs/wti/WTI-POWER-MIB

            ubuntu@nms01:/opt/observium$ sudo svn revert /opt/observium/mibs/wti/WTI-POWER-MIB
            Reverted 'mibs/wti/WTI-POWER-MIB'

            ubuntu@nms01:/opt/observium$ sudo svn status
            ubuntu@nms01:/opt/observium$

            ubuntu@nms01:/opt/observium$ sudo svn update
            Updating '.':
            At revision 10148.

            ubuntu@nms01:/opt/observium$ sudo svn diff
            ubuntu@nms01:/opt/observium$

            Still have these issues:

            WTI image logo is something called "DCN"

            WTI has no ethernet port, but the power sensors are there and working

            Geist has ethernet port but no sensors

             

            derek.sedik@nextlevel.net Next Level added a comment - The diff issue is resolved. ubuntu@nms01:/opt/observium$ sudo svn status D mibs/wti/WTI-POWER-MIB ubuntu@nms01:/opt/observium$ sudo svn revert /opt/observium/mibs/wti/WTI-POWER-MIB Reverted 'mibs/wti/WTI-POWER-MIB' ubuntu@nms01:/opt/observium$ sudo svn status ubuntu@nms01:/opt/observium$ ubuntu@nms01:/opt/observium$ sudo svn update Updating '.': At revision 10148. ubuntu@nms01:/opt/observium$ sudo svn diff ubuntu@nms01:/opt/observium$ Still have these issues: WTI image logo is something called "DCN" WTI has no ethernet port, but the power sensors are there and working Geist has ethernet port but no sensors  
            derek.sedik@nextlevel.net Next Level added a comment -

            ubuntu@nms01:/opt/observium$ sudo svn status
            D mibs/wti/WTI-POWER-MIB

             

            derek.sedik@nextlevel.net Next Level added a comment - ubuntu@nms01:/opt/observium$ sudo svn status D mibs/wti/WTI-POWER-MIB  
            derek.sedik@nextlevel.net Next Level added a comment -

            Sensors work for WTI.  There are no sensors for the Geist (OBS-3140).

            Diff attached.

             

            derek.sedik@nextlevel.net Next Level added a comment - Sensors work for WTI.  There are no sensors for the Geist ( OBS-3140 ). Diff attached.  

            As I see in your log, new sensors already discovered:

            #####  Module Start: sensors  #####
             
             o WTI-POWER-MIB        environmentUnitTemperature [.] environmentUnitCurrentA [.] environmentUnitVoltageA [.] environmentUnitPowerA [.] environmentUnitCurrentB [] environmentUnitVoltageB [] environmentUnitPowerB [] environmentUnitCurrentC [] environmentUnitVoltageC [] environmentUnitPowerC [] environmentUnitCurrentD [] environmentUnitVoltageD [] environmentUnitPowerD [] environmentSystemTotalCurrent [.] environmentSystemTotalPower [.] plugCurrent [.] plugPower [.]

            about logo and other, I not know what you changed locally, show diff:

            svn diff

            landy Mike Stupalov added a comment - As I see in your log, new sensors already discovered: ##### Module Start: sensors #####   o WTI-POWER-MIB environmentUnitTemperature [.] environmentUnitCurrentA [.] environmentUnitVoltageA [.] environmentUnitPowerA [.] environmentUnitCurrentB [] environmentUnitVoltageB [] environmentUnitPowerB [] environmentUnitCurrentC [] environmentUnitVoltageC [] environmentUnitPowerC [] environmentUnitCurrentD [] environmentUnitVoltageD [] environmentUnitPowerD [] environmentSystemTotalCurrent [.] environmentSystemTotalPower [.] plugCurrent [.] plugPower [.] about logo and other, I not know what you changed locally, show diff: svn diff
            derek.sedik@nextlevel.net Next Level added a comment -

            Attached new discovery logs of WTI and Geist.

             

            derek.sedik@nextlevel.net Next Level added a comment - Attached new discovery logs of WTI and Geist.  
            derek.sedik@nextlevel.net Next Level added a comment -

            I deleted the M and ? files, svn up, and now things are better but:

            WTI image logo is something called "DCN"

            WTI has no ethernet port, but the power sensors are there and working

            Geist has ethernet port but no sensors

             

            derek.sedik@nextlevel.net Next Level added a comment - I deleted the M and ? files, svn up, and now things are better but: WTI image logo is something called "DCN" WTI has no ethernet port, but the power sensors are there and working Geist has ethernet port but no sensors  
            derek.sedik@nextlevel.net Next Level added a comment -

            ubuntu@nms01:/opt/observium$ sudo svn status
            M includes/definitions/mibs/wti.inc.php
            M includes/definitions/os.inc.php
            M includes/definitions/vendors.inc.php
            ? mibs/wti/WTI-MPC-VMR-MIB
            D mibs/wti/WTI-POWER-MIB

            derek.sedik@nextlevel.net Next Level added a comment - ubuntu@nms01:/opt/observium$ sudo svn status M includes/definitions/mibs/wti.inc.php M includes/definitions/os.inc.php M includes/definitions/vendors.inc.php ? mibs/wti/WTI-MPC-VMR-MIB D mibs/wti/WTI-POWER-MIB
            derek.sedik@nextlevel.net Next Level added a comment - - edited

            I was able to switch to rolling with http and am at 10148.  However, still no power info.  There were some conflicts during the svn up since I think someone tried modifying the local files before to get this working.  I am not sure I chose the correct options to resolve the conflicts?  How can I force another update so I can choose different options?  Also, for my other ticket there are no sensors for the Geist Watchdog 15.  None of the local files were touched for this device, no conflicts during svn up.

            Added a screenshot of my device list.

             

            derek.sedik@nextlevel.net Next Level added a comment - - edited I was able to switch to rolling with http and am at 10148.  However, still no power info.  There were some conflicts during the svn up since I think someone tried modifying the local files before to get this working.  I am not sure I chose the correct options to resolve the conflicts?  How can I force another update so I can choose different options?  Also, for my other ticket there are no sensors for the Geist Watchdog 15.  None of the local files were touched for this device, no conflicts during svn up. Added a screenshot of my device list.  

            People

              landy Mike Stupalov
              derek.sedik@nextlevel.net Next Level
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: