      dBm is showing the wrong value in GUI for Waystream devices. Attached snmpwalk.

      Attachments

        1. myagent.snmpwalk
          1.54 MB
          Christoffer Smørås

        Activity

          [OBS-3081] dBm using wrong scale for Waystream
          landy Mike Stupalov made changes -
          Status Original: Resolved [ 5 ] New: Closed [ 6 ]
          landy Mike Stupalov made changes -
          Resolution New: Fixed [ 1 ]
          Status Original: In Progress [ 3 ] New: Resolved [ 5 ]

          Improved in r9996.

          landy Mike Stupalov added a comment - Improved in r9996.
          landy Mike Stupalov made changes -
          Status Original: Open [ 1 ] New: In Progress [ 3 ]
          landy Mike Stupalov made changes -
          Labels Original: waystream New: dbm sensors waystream
          landy Mike Stupalov made changes -
          Component/s New: Discovery [ 10001 ]
          Component/s Original: Web Interface [ 10002 ]
          landy Mike Stupalov made changes -
          Assignee Original: Adam Armstrong [ adama ] New: Mike Stupalov [ landy ]