            [OBS-2993] Add Support for RiodoNetworks E3METER PDU

            haha, that how described in mib (since in both dumps humidity was 0 zero).
            Fixed in r9853.

            P.S. Currently both Buchman and Riedo detected separate, but I can combine them then into just Buchman PDU.

            landy Mike Stupalov added a comment - haha, that how described in mib (since in both dumps humidity was 0 zero). Fixed in r9853. P.S. Currently both Buchman and Riedo detected separate, but I can combine them then into just Buchman PDU.

            Just got my Temp/Hum sensors ... They get detected correctly, but Units is off by factor 100!

            See Screenshot (0.25% instead of 25%)

            cramer Matthias Cramer added a comment - Just got my Temp/Hum sensors ... They get detected correctly, but Units is off by factor 100! See Screenshot (0.25% instead of 25%)

            Hi @mike

            As I see you have implemented all under "buchmann". Buchmans PDU are just relabled Riedo PDUs so I would probably be better to change that. But I leave that up to you.

            cramer Matthias Cramer added a comment - Hi @mike As I see you have implemented all under "buchmann". Buchmans PDU are just relabled Riedo PDUs so I would probably be better to change that. But I leave that up to you.

            Works

            dklimek Denis Klimek added a comment - Works

            Added in r9850.

            Energy counter will added later, when counters entity implemented.

            landy Mike Stupalov added a comment - Added in r9850. Energy counter will added later, when counters entity implemented.

            Hi all there

            About energy sensors - this will be as separate entity "counter" with other type of graphs and limits.
            This counters is always grow up, and standard limits don't make sense. There will graphs/options similar as for ports (but not same).

            Currently I will do implement all other sensors (exept all energy).

            landy Mike Stupalov added a comment - Hi all there About energy sensors - this will be as separate entity "counter" with other type of graphs and limits. This counters is always grow up, and standard limits don't make sense. There will graphs/options similar as for ports (but not same). Currently I will do implement all other sensors (exept all energy).

            Hi Denis

             

            As i just saw, there is already min and max if you show the legend in the detail graph. But It is very meaningless if the watthour counter is very high.

            Probably we should display de difference of max and min...

            cramer Matthias Cramer added a comment - Hi Denis   As i just saw, there is already min and max if you show the legend in the detail graph. But It is very meaningless if the watthour counter is very high. Probably we should display de difference of max and min...

            Ehhh! Yeah you're right, i mean first-max / min-max

            dklimek Denis Klimek added a comment - Ehhh! Yeah you're right, i mean first-max / min-max
            cramer Matthias Cramer added a comment - - edited

            Will also implement humidity as soon as I receive the corresponding sensors (today or tomorrow),,,

             

            cramer Matthias Cramer added a comment - - edited Will also implement humidity as soon as I receive the corresponding sensors (today or tomorrow),,,  

            Hi Denis

            Last and Max would always be the same in this case, you mean first and last or first and max.

            I can investigate if I could tweak the graph to do that.

            cramer Matthias Cramer added a comment - Hi Denis Last and Max would always be the same in this case, you mean first and last or first and max. I can investigate if I could tweak the graph to do that.

            Latest patch works great! Thank you Matthias.

            We have one improvement suggestion regarding the collection of the "Energy (Wh)" values. Would it be possible to adjust the RRD graph to see the differences between Last and Max? Mostly you've billing cycles for a week/month i.e. (1st to 31st of a month) and then you could select "last week/month" to get the value of the total consumed kWh.

            dklimek Denis Klimek added a comment - Latest patch works great! Thank you Matthias. We have one improvement suggestion regarding the collection of the "Energy (Wh)" values. Would it be possible to adjust the RRD graph to see the differences between Last and Max? Mostly you've billing cycles for a week/month i.e. (1st to 31st of a month) and then you could select "last week/month" to get the value of the total consumed kWh.