    Description

      Observium shows a wrong IP address for the ethernet ports on our Bintec routers.
      The first block of the IP address is cut off. All our Bintec-devices are affected.

      Correct IP: 192.168.0.84
      IP shown in observium-gui: 168.0.84.0

      snmpget result = iso.3.6.1.2.1.4.20.1.1.192.168.0.84.0 = IpAddress: 192.168.0.84

      It seems that the IP is extracted from the last 4 blocks of the OID instead of taking the actual value.

      Device-OS: BinTec OS 10.1 Rev. 4 (Patch 3) (R3002)

      Attachments

        Activity

          [OBS-1958] Wrong IPv4 address discovered on Bintec/Funkwerk devices
          landy Mike Stupalov made changes -
          Status Original: Resolved [ 5 ] New: Closed [ 6 ]
          landy Mike Stupalov made changes -
          Issue Type Original: Bug [ 1 ] New: Vendor Bug [ 10000 ]
          Resolution New: Fixed [ 1 ]
          Status Original: Pending Response [ 10000 ] New: Resolved [ 5 ]
          philipp.lamers Philipp Lamers made changes -
          Attachment New: discovery.txt [ 13294 ]
          landy Mike Stupalov made changes -
          Labels New: ip
          Priority Original: Major [ 3 ] New: Minor [ 4 ]
          Status Original: Open [ 1 ] New: Pending Response [ 10000 ]