Details
Description
Observium shows a wrong IP address for the ethernet ports on our Bintec routers.
The first block of the IP address is cut off. All our Bintec-devices are affected.
Correct IP: 192.168.0.84
IP shown in observium-gui: 168.0.84.0
snmpget result = iso.3.6.1.2.1.4.20.1.1.192.168.0.84.0 = IpAddress: 192.168.0.84
It seems that the IP is extracted from the last 4 blocks of the OID instead of taking the actual value.
Device-OS: BinTec OS 10.1 Rev. 4 (Patch 3) (R3002)
Attachments
Activity
Status | Original: Resolved [ 5 ] | New: Closed [ 6 ] |
Issue Type | Original: Bug [ 1 ] | New: Vendor Bug [ 10000 ] |
Resolution | New: Fixed [ 1 ] | |
Status | Original: Pending Response [ 10000 ] | New: Resolved [ 5 ] |
Attachment | New: discovery.txt [ 13294 ] |
Labels | New: ip | |
Priority | Original: Major [ 3 ] | New: Minor [ 4 ] |
Status | Original: Open [ 1 ] | New: Pending Response [ 10000 ] |