DEBUG! CMD[/usr/bin/svn info /opt/observium]  CMD EXITCODE[0] CMD RUNTIME[0.0219s] CMD EXITDELAY[5ms] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: https://svn.observium.org/svn/observium/branches/stable Relative URL: ^/observium/branches/stable Repository Root: https://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 14350 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 14182 Last Changed Date: 2025-08-21 07:47:57 +0200 (Thu, 21 Aug 2025) ]  CMD[/usr/bin/svn auth svn.observium.org | awk '/Username:/ {print $2}']  CMD EXITCODE[0] CMD RUNTIME[0.0252s] CMD EXITDELAY[5ms] STDOUT[ criens-33259703 ] DEFINITIONS Time : 0.190418 ms DEFINITIONS Memory: 16.8MB SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.0007112s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00069594s]  SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00054002s] DB mode(s) disabled: STRICT_TRANS_TABLES, ERROR_FOR_DIVISION_BY_ZERO SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00073695s] DB timezone different from php timezone. Syncing.. SQL[SELECT version();] SQL RUNTIME[0.00057483s]  SQL[SET SESSION time_zone='+00:00';] SQL RUNTIME[0.00056505s]  SQL[SELECT * FROM `config`] SQL RUNTIME[0.00059581s]  SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)] SQL RUNTIME[0.00049114s]  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 25.8.14182 https://www.observium.org   CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.0426s] STDOUT[ Linux|6.12.43+deb13-amd64|amd64|Debian|13|vmware| ]  CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0056s] CMD EXITDELAY[5ms] STDOUT[ Python 3.13.5 ]  SQL[SELECT version();] SQL RUNTIME[0.00109911s]  CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0094s] CMD EXITDELAY[5ms] STDOUT[ NET-SNMP version: 5.9.4.pre2 ]  CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0159s] STDOUT[ RRDtool 1.7.2 Copyright by Tobias Oetiker ]  CMD[/usr/bin/rrdcached -h | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0158s] CMD EXITDELAY[5ms] STDOUT[ RRDCacheD 1.7.2 ]  CMD[/usr/bin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0036s] CMD EXITDELAY[5ms] STDOUT[ /usr/bin/fping: Version 5.1 ]  CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0203s] STDOUT[ Apache/2.4.65 ]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00077415s]  SQL[SHOW VARIABLES LIKE 'log_bin'] SQL RUNTIME[0.001863s]  SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.0020442s]  ##### Observium #####   o Version  25.8.14182  o Train  stable  o Released  21st August 2025  o Subscription User  criens-33259703 ##### Software versions #####   o OS  Linux 6.12.43+deb13-amd64 [amd64] (Debian 13)  o VM  VMware Virtual Machine  o Apache  2.4.65  o PHP  8.4.11  o Python  3.13.5  o MariaDB  11.8.3-MariaDB-0+deb13u1 from Debian (extension: mysqli 8.4.11)  o SNMP  NET-SNMP 5.9.4.pre2  o RRDtool  1.7.2 (rrdcached 1.7.2: unix:/var/run/rrdcached.sock)  o Fping  5.1 (IPv4 and IPv6)  o Fetch  cURL 8.14.1 (OpenSSL/3.5.4, LibZ 1.3.1, LibIDN 2.3.8) ##### PHP info #####   o OPcache  DISABLED  o Memory Limit  Unlimited  o Math  BCMATH ##### DB info #####   o DB schema  500  o MariaDB binlog  OFF  o MariaDB mode  NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MariaDB  utf8mb3 ##### Timezones info #####   o Date  Friday, 21-Nov-25 15:51:50 UTC  o PHP  +00:00  o MariaDB  +01:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1763740310' AND `maint_end` > '1763740310'] SQL RUNTIME[0.00105309s] ##### Starting polling run at 2025-11-21 15:51:50 #####   SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` = 'ups24-datacenter.cri.ulm' AND `poller_id` = '0' ORDER BY `device_id` ASC] SQL RUNTIME[0.00106907s]  SQL[SELECT * FROM `devices` WHERE `device_id` = '855'] SQL RUNTIME[0.00103402s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '855'] SQL RUNTIME[0.00069189s] Array ( [device_id] => 855 [poller_id] => 0 [hostname] => ups24-datacenter.cri.ulm [sysName] => ups24-datacenter.cri.ulm [label] => [ip] => 10.110.10.13 [snmp_community] => supcri [snmp_authlevel] => [snmp_authname] => [snmp_authpass] => [snmp_authalgo] => [snmp_cryptopass] => [snmp_cryptoalgo] => [snmp_context] => [snmpable] => [snmp_version] => v2c [snmp_port] => 161 [snmp_timeout] => [snmp_retries] => [snmp_maxrep] => [ssh_port] => 22 [agent_version] => [snmp_transport] => udp [bgpLocalAs] => [snmpEngineID] => 80001F880300E0D8204D0E [sysObjectID] => .1.3.6.1.4.1.4555.1.1.7 [sysDescr] => NetVision-8 [sysContact] => Technical Support Team [version] => 8.30 [hardware] => DELPHYS GP 2.0 [vendor] => Socomec [features] => [location] => [os] => netvision-ng [status] => 1 [status_type] => ok [ignore] => 0 [ignore_until] => [asset_tag] => [disabled] => 0 [uptime] => 14518483 [last_rebooted] => 1749221957 [force_discovery] => 0 [last_polled] => 2025-11-21 15:50:15 [last_discovered] => 2025-11-21 15:51:32 [last_alerter] => 2025-11-21 15:50:15 [last_polled_timetaken] => 0.78 [last_discovered_timetaken] => 3.48 [purpose] => [type] => power [serial] => 22100HPKN04380001 [icon] => [device_state] => a:5:{s:15:"poller_mod_perf";a:18:{s:6:"system";d:0.1469;s:2:"os";d:0.0681;s:7:"sensors";d:0.1861;s:6:"status";d:0.0345;s:7:"counter";d:0.0008;s:10:"processors";d:0.0022;s:8:"mempools";d:0.0011;s:7:"storage";d:0.0015;s:13:"ipSystemStats";d:0.0227;s:5:"ports";d:0.1654;s:15:"printersupplies";d:0.0008;s:10:"ucd-diskio";d:0.0008;s:12:"loadbalancer";d:0.0002;s:15:"entity-physical";d:0.0002;s:9:"fdb-table";d:0.0308;s:6:"graphs";d:0.049;s:4:"oids";d:0.001;s:6:"probes";d:0.001;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.050755977630615234;s:13:"EtherLike-MIB";d:0.00010704994201660156;s:12:"Q-BRIDGE-MIB";d:0.10744404792785645;s:6:"IP-MIB";d:0.00016808509826660156;}s:14:"poller_history";a:288:{i:1763740214;d:0.7751;i:1763739910;d:0.7475;i:1763739581;d:0.7513;i:1763739312;d:0.7649;i:1763739026;d:0.7465;i:1763738740;d:0.7297;i:1763738497;d:0.7223;i:1763738155;d:0.7403;i:1763737783;d:0.7302;i:1763737514;d:0.7323;i:1763737201;d:0.8738;i:1763736893;d:0.778;i:1763736605;d:0.7297;i:1763736291;d:0.7021;i:1763736013;d:0.7834;i:1763735712;d:0.7541;i:1763735415;d:0.7911;i:1763735132;d:0.8034;i:1763734862;d:0.807;i:1763734529;d:0.7104;i:1763734249;d:0.707;i:1763733947;d:0.6838;i:1763733649;d:0.7483;i:1763733325;d:0.764;i:1763733035;d:0.8226;i:1763732711;d:0.7278;i:1763732415;d:0.7765;i:1763732108;d:0.7274;i:1763731789;d:0.735;i:1763731509;d:0.788;i:1763731234;d:0.753;i:1763730911;d:0.7166;i:1763730648;d:0.7399;i:1763730320;d:0.7845;i:1763730019;d:0.757;i:1763729731;d:0.7896;i:1763729419;d:0.7818;i:1763729130;d:0.8183;i:1763728821;d:0.8436;i:1763728527;d:0.7482;i:1763728212;d:0.7507;i:1763727948;d:0.7419;i:1763727673;d:0.7309;i:1763727361;d:0.7031;i:1763727050;d:0.7983;i:1763726739;d:0.7606;i:1763726426;d:0.7904;i:1763726039;d:0.7285;i:1763725854;d:0.7083;i:1763725551;d:0.7406;i:1763725276;d:0.7662;i:1763724946;d:0.7622;i:1763724670;d:5.753;i:1763724351;d:0.6997;i:1763724074;d:0.7733;i:1763723756;d:0.7261;i:1763723446;d:0.7323;i:1763723138;d:0.7693;i:1763722797;d:0.7134;i:1763722496;d:0.7603;i:1763722203;d:0.7889;i:1763721917;d:0.7394;i:1763721626;d:0.772;i:1763721321;d:0.7445;i:1763721024;d:0.7656;i:1763720749;d:0.7123;i:1763720493;d:0.7416;i:1763720188;d:0.7653;i:1763719917;d:0.7505;i:1763719582;d:0.712;i:1763719254;d:0.7752;i:1763718980;d:0.7677;i:1763718686;d:0.7732;i:1763718432;d:0.7741;i:1763718205;d:0.7073;i:1763718051;d:0.7221;i:1763717758;d:0.7664;i:1763717244;d:0.7196;i:1763717032;d:0.7559;i:1763716731;d:0.7991;i:1763716257;d:0.7177;i:1763715955;d:0.6848;i:1763715611;d:0.7924;i:1763715317;d:0.737;i:1763715008;d:0.7115;i:1763714680;d:0.7378;i:1763714444;d:0.7448;i:1763714134;d:0.7181;i:1763713814;d:0.7976;i:1763713518;d:0.6957;i:1763713204;d:0.7721;i:1763712940;d:0.7571;i:1763712568;d:0.6918;i:1763712277;d:0.7583;i:1763711966;d:0.722;i:1763711689;d:0.7773;i:1763711343;d:0.764;i:1763711061;d:0.7537;i:1763710766;d:0.764;i:1763710451;d:0.7419;i:1763710135;d:0.7357;i:1763709834;d:0.7265;i:1763709566;d:0.7121;i:1763709277;d:0.7046;i:1763708969;d:0.7558;i:1763708669;d:0.6979;i:1763708319;d:0.7719;i:1763708023;d:0.7667;i:1763707740;d:0.7434;i:1763707475;d:0.7567;i:1763707146;d:1.7324;i:1763706843;d:0.7553;i:1763706549;d:0.7153;i:1763706261;d:0.708;i:1763705983;d:0.7436;i:1763705664;d:0.7382;i:1763705368;d:0.781;i:1763705076;d:0.7771;i:1763704755;d:0.7577;i:1763704450;d:0.742;i:1763704152;d:0.7385;i:1763703851;d:0.7543;i:1763703531;d:0.7108;i:1763703232;d:0.7178;i:1763702943;d:0.6938;i:1763702647;d:0.7857;i:1763702375;d:0.7523;i:1763702066;d:0.7339;i:1763701768;d:0.7341;i:1763701430;d:0.6838;i:1763701156;d:0.7099;i:1763700831;d:0.7377;i:1763700580;d:0.7072;i:1763700249;d:0.764;i:1763699962;d:0.7221;i:1763699632;d:0.7239;i:1763699302;d:0.7187;i:1763699054;d:0.7202;i:1763698769;d:0.7437;i:1763698482;d:0.77;i:1763698166;d:1.7296;i:1763697840;d:0.7238;i:1763697543;d:0.7615;i:1763697233;d:0.7594;i:1763696942;d:0.7113;i:1763696642;d:0.7198;i:1763696355;d:0.7086;i:1763696045;d:0.7279;i:1763695731;d:0.692;i:1763695444;d:0.7799;i:1763695184;d:0.7339;i:1763694911;d:0.7734;i:1763694563;d:0.7293;i:1763694265;d:0.7396;i:1763693979;d:0.6871;i:1763693646;d:0.7094;i:1763693374;d:0.7309;i:1763693075;d:0.691;i:1763692763;d:0.7887;i:1763692447;d:0.7506;i:1763692151;d:0.7675;i:1763691857;d:0.7611;i:1763691563;d:0.7446;i:1763691292;d:0.7254;i:1763690982;d:0.796;i:1763690672;d:0.738;i:1763690347;d:0.7567;i:1763690047;d:0.7374;i:1763689744;d:0.7688;i:1763689433;d:0.7762;i:1763689168;d:0.7393;i:1763688841;d:0.7447;i:1763688617;d:0.7714;i:1763688271;d:0.7158;i:1763688003;d:0.7699;i:1763687685;d:0.7365;i:1763687359;d:0.704;i:1763687049;d:0.7574;i:1763686746;d:0.7695;i:1763686465;d:0.7411;i:1763686150;d:0.765;i:1763685831;d:0.6993;i:1763685536;d:0.7802;i:1763685230;d:0.7401;i:1763684954;d:0.7637;i:1763684661;d:0.7874;i:1763684361;d:0.7279;i:1763684063;d:0.7121;i:1763683749;d:0.7523;i:1763683480;d:0.7751;i:1763683184;d:0.7468;i:1763682852;d:0.7381;i:1763682576;d:0.7115;i:1763682260;d:0.7423;i:1763681947;d:0.7327;i:1763681651;d:0.8099;i:1763681353;d:0.7447;i:1763681074;d:0.732;i:1763680776;d:0.7382;i:1763680506;d:0.7632;i:1763680174;d:0.7297;i:1763679878;d:0.7171;i:1763679565;d:0.8012;i:1763679264;d:0.7054;i:1763678969;d:0.7358;i:1763678674;d:0.7342;i:1763678349;d:0.7563;i:1763678063;d:0.7981;i:1763677756;d:0.7949;i:1763677459;d:0.7638;i:1763677198;d:0.8293;i:1763676887;d:0.7515;i:1763676598;d:0.7432;i:1763676299;d:0.7589;i:1763675954;d:0.7635;i:1763675674;d:0.7297;i:1763675360;d:0.7934;i:1763675072;d:0.7921;i:1763674744;d:0.7122;i:1763674477;d:0.7657;i:1763674197;d:0.7378;i:1763673878;d:0.7524;i:1763673606;d:0.7932;i:1763673285;d:0.7358;i:1763672980;d:0.7872;i:1763672668;d:0.6946;i:1763672405;d:0.8329;i:1763672069;d:0.762;i:1763671784;d:0.7351;i:1763671508;d:0.7445;i:1763671136;d:0.7824;i:1763670868;d:0.7026;i:1763670561;d:0.7619;i:1763670274;d:0.737;i:1763669964;d:1.7155;i:1763669680;d:0.881;i:1763669365;d:0.7088;i:1763669111;d:0.7644;i:1763668770;d:0.7114;i:1763668462;d:0.7183;i:1763668155;d:0.7648;i:1763667864;d:0.782;i:1763667570;d:0.7333;i:1763667254;d:0.7441;i:1763666963;d:0.7905;i:1763666651;d:0.9803;i:1763666399;d:0.904;i:1763666074;d:0.7317;i:1763665751;d:0.8808;i:1763665466;d:1.3955;i:1763665128;d:0.7186;i:1763664830;d:0.7553;i:1763664546;d:0.758;i:1763664240;d:0.7617;i:1763663916;d:0.7272;i:1763663633;d:0.7469;i:1763663324;d:0.7978;i:1763663049;d:0.7985;i:1763662765;d:0.7015;i:1763662482;d:0.7329;i:1763662177;d:0.7505;i:1763661851;d:0.7752;i:1763661561;d:0.7466;i:1763661286;d:0.7259;i:1763660967;d:0.6728;i:1763660672;d:0.7968;i:1763660361;d:0.7197;i:1763660074;d:0.699;i:1763659771;d:0.7032;i:1763659504;d:0.7671;i:1763659254;d:0.7718;i:1763658871;d:0.7465;i:1763658572;d:0.7325;i:1763658318;d:0.7924;i:1763657996;d:0.6611;i:1763657668;d:0.7592;i:1763657364;d:0.7546;i:1763657097;d:0.7553;i:1763656814;d:0.7889;i:1763656501;d:0.7751;i:1763656214;d:0.7558;i:1763655932;d:0.7922;i:1763655640;d:0.7502;i:1763655382;d:0.7013;i:1763655068;d:0.7524;i:1763654801;d:0.7377;i:1763654546;d:0.7493;i:1763654419;d:0.7826;}s:17:"discovery_history";a:100:{i:1763740288;d:3.4821;i:1763724821;d:2.3726;i:1763703212;d:2.0967;i:1763681614;d:2.0858;i:1763660034;d:2.0252;i:1763650458;d:2.5142;i:1763616813;d:272.7564;i:1763595227;d:2.0346;i:1763573617;d:2.2476;i:1763552022;d:2.2766;i:1763530417;d:2.149;i:1763508814;d:2.1682;i:1763487225;d:2.199;i:1763465610;d:2.3714;i:1763444021;d:2.0346;i:1763422417;d:2.2388;i:1763400812;d:2.1825;i:1763379215;d:2.3203;i:1763357609;d:2.1019;i:1763336013;d:2.1189;i:1763314420;d:2.2217;i:1763292820;d:2.1847;i:1763271218;d:2.4175;i:1763249617;d:2.0702;i:1763228023;d:2.0506;i:1763206419;d:2.1485;i:1763184812;d:2.0045;i:1763163214;d:2.1;i:1763141609;d:2.1234;i:1763120015;d:2.211;i:1763098419;d:2.1049;i:1763076824;d:2.0609;i:1763055217;d:2.2514;i:1763033619;d:2.343;i:1763012013;d:2.1525;i:1762990414;d:2.005;i:1762968819;d:2.2185;i:1762947221;d:2.3136;i:1762925615;d:2.2303;i:1762904016;d:2.0773;i:1762882417;d:2.1797;i:1762860824;d:2.2632;i:1762839220;d:2.1899;i:1762817620;d:2.1764;i:1762796024;d:2.1657;i:1762774413;d:2.2797;i:1762752812;d:2.1543;i:1762731204;d:2.22;i:1762709612;d:2.2158;i:1762688005;d:2.2331;i:1762666415;d:2.1907;i:1762644809;d:2.1726;i:1762623222;d:2.2039;i:1762601612;d:2.2755;i:1762580010;d:2.2731;i:1762558417;d:2.1542;i:1762536811;d:2.1378;i:1762515209;d:2.284;i:1762493611;d:2.1136;i:1762472007;d:2.1643;i:1762450417;d:2.2058;i:1762428812;d:2.3586;i:1762407211;d:2.2056;i:1762385614;d:2.2162;i:1762364004;d:2.203;i:1762342415;d:2.17;i:1762320815;d:2.4106;i:1762299226;d:2.3167;i:1762277613;d:2.2806;i:1762256016;d:2.3245;i:1762234440;d:2.5276;i:1762212817;d:2.2586;i:1762191212;d:2.3033;i:1762169612;d:2.2558;i:1762148021;d:2.1495;i:1762126411;d:2.2184;i:1762104809;d:2.2295;i:1762083209;d:2.2314;i:1762061611;d:2.201;i:1762040011;d:2.2032;i:1762018418;d:2.1459;i:1761996816;d:2.147;i:1761975205;d:2.1418;i:1761953614;d:2.1471;i:1761932004;d:2.167;i:1761910417;d:2.2038;i:1761888807;d:2.1839;i:1761867216;d:2.1983;i:1761845612;d:2.2889;i:1761824008;d:2.1429;i:1761802412;d:2.1595;i:1761780810;d:2.1605;i:1761759218;d:2.208;i:1761737621;d:2.197;i:1761716013;d:2.1389;i:1761694410;d:2.3913;i:1761672809;d:2.2436;i:1761651218;d:2.2622;i:1761629617;d:2.0855;i:1761608017;d:2.0534;}s:18:"discovery_mod_perf";a:15:{s:2:"os";d:0.0885;s:4:"mibs";d:0.119;s:5:"ports";d:0.1286;s:4:"oids";d:0.1376;s:12:"ip-addresses";d:0.1252;s:10:"processors";d:0.0539;s:8:"mempools";d:0.0403;s:9:"inventory";d:0.1474;s:7:"sensors";d:2.1939;s:7:"storage";d:0.0616;s:10:"neighbours";d:0.0988;s:9:"arp-table";d:0.1058;s:14:"mac-accounting";d:0.0002;s:10:"ucd-diskio";d:0.0317;s:6:"graphs";d:0.0003;}} [distro] => [distro_ver] => [kernel] => [arch] => [attribs] => Array ( ) ) SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '855' AND `poller_id` = '0'] SQL RUNTIME[0.00104809s]  SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('3678779','poller.php','3412227','0','php /opt/observium/poller.php -d -h ups24-datacenter.cri.ulm','1763740309','855')] SQL RUNTIME[0.00239396s]  SQL[SELECT * FROM `alert_tests`] SQL RUNTIME[0.00073004s] Cached 18 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '855'] SQL RUNTIME[0.00178385s] ##### ups24-datacenter.cri.ulm [855] #####   o OS  netvision-ng  o OS Group  ups  o Last poll duration  0.78 seconds  o Last Polled  2025-11-21 15:50:15  o SNMP Version  v2c CMD[/usr/bin/fping -t 1000 -c 1 -q 10.110.10.13 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0055s] CMD EXITDELAY[5ms] STDOUT[ 10.110.10.13 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 0.580/0.580/0.580 ] Return cached 'ups24-datacenter.cri.ulm' = '10.110.10.13' CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.0239s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.4555.1.1.7 .1.3.6.1.2.1.1.3.0 = 168:0:56:18.84 ] SNMP STATUS[TRUE]  o Device status  Device is reachable by PING (0.580ms) and SNMP (23.93ms) Return cached 'ups24-datacenter.cri.ulm' = '10.110.10.13' RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/status.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/status.rrd N:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.05] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/ping.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/ping.rrd N:0.580 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.06] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/ping_snmp.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/ping_snmp.rrd N:23.93 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.06] RRD_STATUS[TRUE]   SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '855'] SQL RUNTIME[0.00120497s]  o Modules Excluded  unix-agent, wmi, ipmi, junose-atm-vp, cisco-ipsec-flow-monitor, cisco-remote-access-monitor, cisco-cef, arista-software-ip-forwarding,cipsec-tunnels, cisco-cbqos, cisco-eigrp, aruba-controller, cisco-vpdn  o Modules Disabled  applications, netstats, ucd-mib, bgp-peers, wifi, p2p-radios, ospf, sla, lsp, pseudowires, mac-accounting, syslog  o Modules Enabled  system, os, sensors, status, counter, processors, mempools, storage, ipSystemStats, ports, printersupplies, ucd-diskio, loadbalancer,entity-physical, fdb-table, graphs, oids, processes, probes including: includes/polling/system.inc.php ##### Module Start: system #####  JSON DECODE[Not string passed] JSON RAW[ ] JSON DECODE[Not string passed] JSON RAW[ ] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '855' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00050998s]  o SNMPv2-MIB   CMD[/usr/bin/snmpget -v2c -c *** -Pud -Irh -OQUsx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0]  CMD EXITCODE[0] CMD RUNTIME[0.0234s] STDOUT[ sysUpTime.0 = 168:0:56:18.89 sysLocation.0 = "" sysContact.0 = "54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 54 65 61 6D " sysName.0 = "75 70 73 32 34 2D 64 61 74 61 63 65 6E 74 65 72 2E 63 72 69 2E 75 6C 6D " ] SNMP Hex string converted.. HEX: 54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 54 65 61 6D STRING: Technical Support Team SNMP Hex string converted.. HEX: 75 70 73 32 34 2D 64 61 74 61 63 65 6E 74 65 72 2E 63 72 69 2E 75 6C 6D STRING: ups24-datacenter.cri.ulm SNMP STATUS[TRUE] Timeticks converted 168:0:56:18.89 -> 14518578 CMD[/usr/bin/snmpget -v2c -c *** -Pud -Irh -OQUvx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0216s] STDOUT[ "4E 65 74 56 69 73 69 6F 6E 2D 38 " ] SNMP Hex string converted.. HEX: 4E 65 74 56 69 73 69 6F 6E 2D 38 STRING: NetVision-8 SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0161s] STDOUT[ .1.3.6.1.4.1.4555.1.1.7 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' snmpEngineID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0122s] STDOUT[ "80 00 1F 88 03 00 E0 D8 20 4D 0E " ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUv -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' hrSystemUptime.0]  CMD EXITCODE[0] CMD RUNTIME[0.0204s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemUptime.0';] SQL RUNTIME[0.00209117s]  SQL[UPDATE `snmp_errors` set `error_count` ='48071',`updated` ='1763740310' WHERE `error_id` = '102072'] SQL RUNTIME[0.002285s]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' snmpEngineTime.0]  CMD EXITCODE[0] CMD RUNTIME[0.0128s] CMD EXITDELAY[5ms] STDOUT[ 14518579 ] SNMP STATUS[TRUE] Using SNMP Agent snmpEngineTime (14518579 sec. => 168 days, 56m 19s) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/uptime.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/uptime.rrd N:14518579 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.21] RRD_STATUS[TRUE]   o Uptime  168 days, 56m 19s  o Last reboot  06.06.2025 14:59:17 Array ( [use] => snmpEngineTime [sysUpTime] => 14518578 [hrSystemUptime] => [snmpEngineTime] => 14518579 [uptime] => 14518579 [formatted] => 168 days, 56m 19s [message] => Using SNMP Agent snmpEngineTime [previous] => 14518483 [diff] => -96 [last_rebooted] => 1749221957 [rebooted] => 0 ) CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3]  CMD EXITCODE[0] CMD RUNTIME[0.0121s] STDOUT[ .1.3.6.1.4.1.2021.10.1.5.1 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.2 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.3 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';] SQL RUNTIME[0.00106597s]  SQL[UPDATE `snmp_errors` set `error_count` ='123846',`updated` ='1763740310' WHERE `error_id` = '94652'] SQL RUNTIME[0.00199699s] SNMP STATUS[FALSE]  o sysObjectID  .1.3.6.1.4.1.4555.1.1.7  o snmpEngineID  80001F880300E0D8204D0E  o sysDescr  NetVision-8  o sysName  ups24-datacenter.cri.ulm  o Location   SQL[SELECT *, UNIX_TIMESTAMP(`location_updated`) AS `location_unixtime` FROM `devices_locations` WHERE `device_id` = '855'] SQL RUNTIME[0.000875s]  o Module time  0.1762s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-system.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-system.rrd N:0.1762 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.25] RRD_STATUS[TRUE]   including: includes/polling/os.inc.php ##### Module Start: os #####   CMD[/usr/bin/snmpget -v2c -c *** -Pud -Irh -OQUvbx --hexOutputLength=0 -m SOCOMECUPS7-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/socomec 'udp':'ups24-datacenter.cri.ulm':'161' upsIdentSerialNumber.0]  CMD EXITCODE[0] CMD RUNTIME[0.026s] STDOUT[ "32 32 31 30 30 48 50 4B 4E 30 34 33 38 30 30 30 31 " ] SNMP Hex string converted.. HEX: 32 32 31 30 30 48 50 4B 4E 30 34 33 38 30 30 30 31 STRING: 22100HPKN04380001 SNMP STATUS[TRUE] Added Device param from SNMP definition by [SOCOMECUPS7-MIB::upsIdentSerialNumber.0]: 'serial' = '22100HPKN04380001' CMD[/usr/bin/snmpget -v2c -c *** -Pud -Irh -OQUvbx --hexOutputLength=0 -m SOCOMECUPS7-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/socomec 'udp':'ups24-datacenter.cri.ulm':'161' upsIdentAgentSoftwareVersion.0]  CMD EXITCODE[0] CMD RUNTIME[0.0153s] STDOUT[ "4E 65 74 20 56 69 73 69 6F 6E 20 38 20 76 38 2E 33 30 " ] SNMP Hex string converted.. HEX: 4E 65 74 20 56 69 73 69 6F 6E 20 38 20 76 38 2E 33 30 STRING: Net Vision 8 v8.30 SNMP STATUS[TRUE]  String 'Net Vision 8 v8.30' transformed by action [explode] to: 'v8.30' String 'v8.30' transformed by action [replace] to: '8.30' Added Device param from SNMP definition by [SOCOMECUPS7-MIB::upsIdentAgentSoftwareVersion.0]: 'version' = '8.30' CMD[/usr/bin/snmpget -v2c -c *** -Pud -Irh -OQUvbx --hexOutputLength=0 -m SOCOMECUPS7-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/socomec 'udp':'ups24-datacenter.cri.ulm':'161' upsIdentModel.0]  CMD EXITCODE[0] CMD RUNTIME[0.0144s] STDOUT[ "44 45 4C 50 48 59 53 20 47 50 20 32 2E 30 " ] SNMP Hex string converted.. HEX: 44 45 4C 50 48 59 53 20 47 50 20 32 2E 30 STRING: DELPHYS GP 2.0 SNMP STATUS[TRUE] Added Device param from SNMP definition by [SOCOMECUPS7-MIB::upsIdentModel.0]: 'hardware' = 'DELPHYS GP 2.0' Array ( [serial] => 22100HPKN04380001 [version] => 8.30 [hardware] => DELPHYS GP 2.0 )  o OS Poller  Generic  o Type  Power  o Vendor  Socomec  o Hardware  DELPHYS GP 2.0  o Version  8.30  o Features    o Serial  22100HPKN04380001  o Asset    o Module time  0.0634s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-os.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-os.rrd N:0.0634 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.31] RRD_STATUS[TRUE]   including: includes/polling/sensors.inc.php ##### Module Start: sensors #####   SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '855' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','power','apower','rpower','crestfactor','powerfactor','impedance','resistance','capacitance','frequency','dbm','attenuation','snr','sound','dust','concentration','capacity','load','volume','waterflow','pressure','velocity','distance','illuminance','wavelength','runtime','age','gauge')] SQL RUNTIME[0.00240803s]  SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '855' AND `entity_type` = 'sensor'] SQL RUNTIME[0.00087309s]  SQL[SELECT DISTINCT `sensor_oid` FROM `sensors` WHERE `device_id` = '855' AND `sensor_deleted` = '0' AND `poller_type` = 'snmp'] SQL RUNTIME[0.00141811s] Passed to snmp_get_multi_oid() Oids count (38) more than max-get (16). Command snmpget splitted to multiple chunks. CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.4.1.4555.1.1.1.1.2.2.0 .1.3.6.1.4.1.4555.1.1.1.1.2.3.0 .1.3.6.1.4.1.4555.1.1.1.1.2.4.0 .1.3.6.1.4.1.4555.1.1.1.1.3.2.0 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.1 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.2 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.3 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.1 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.2 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.3 .1.3.6.1.4.1.4555.1.1.1.1.4.2.0 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.1 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.2 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.3 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.1 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.2]  CMD EXITCODE[0] CMD RUNTIME[0.0224s] STDOUT[ .1.3.6.1.4.1.4555.1.1.1.1.2.2.0 = 0 .1.3.6.1.4.1.4555.1.1.1.1.2.3.0 = 17 .1.3.6.1.4.1.4555.1.1.1.1.2.4.0 = 100 .1.3.6.1.4.1.4555.1.1.1.1.3.2.0 = 499 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.1 = 2320 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.2 = 2320 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.3 = 2320 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.1 = 0 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.2 = 0 .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.3 = 0 .1.3.6.1.4.1.4555.1.1.1.1.4.2.0 = 500 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.1 = 2310 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.2 = 2300 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.3 = 2300 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.1 = 700 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.2 = 640 ]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.3 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.1 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.2 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.3 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.1 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.2 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.3 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.1 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.2 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.3 .1.3.6.1.4.1.4555.1.1.7.1.2.5.0 .1.3.6.1.4.1.4555.1.1.7.1.2.7.0 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.1 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.2 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.3 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.1]  CMD EXITCODE[0] CMD RUNTIME[0.0284s] CMD EXITDELAY[5ms] STDOUT[ .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.3 = 480 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.1 = 19 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.2 = 17 .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.3 = 13 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.1 = 2320 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.2 = 2310 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.3 = 2310 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.1 = 0 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.2 = 0 .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.3 = 0 .1.3.6.1.4.1.4555.1.1.7.1.2.5.0 = 5670 .1.3.6.1.4.1.4555.1.1.7.1.2.7.0 = 230 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.1 = 160 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.2 = 140 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.3 = 110 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.1 = 150 ]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.2 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.3 .1.3.6.1.4.1.4555.1.1.7.1.4.5.0 .1.3.6.1.4.1.4555.1.1.7.1.4.6.0 .1.3.6.1.4.1.4555.1.1.7.1.4.7.0 .1.3.6.1.4.1.4555.1.1.7.1.5.1.0]  CMD EXITCODE[0] CMD RUNTIME[0.0219s] STDOUT[ .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.2 = 140 .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.3 = 100 .1.3.6.1.4.1.4555.1.1.7.1.4.5.0 = 410 .1.3.6.1.4.1.4555.1.1.7.1.4.6.0 = 390 .1.3.6.1.4.1.4555.1.1.7.1.4.7.0 = 19 .1.3.6.1.4.1.4555.1.1.7.1.5.1.0 = 500 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00163603s] Checking (snmp) capacity Battery Charge Remaining Array ( [sensor_id] => 24683 [sensor_deleted] => 0 [sensor_class] => capacity [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.2.4.0 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsEstimatedChargeRemaining [sensor_index] => 0 [sensor_type] => SOCOMECUPS-MIB-upsEstimatedChargeRemaining [sensor_descr] => Battery Charge Remaining [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => 15 [sensor_limit_low_warn] => 30 [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 100.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.2.4.0 = 100 Array ( [sensor_value] => 100 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-capacity-SOCOMECUPS-MIB-upsEstimatedChargeRemaining-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-capacity-SOCOMECUPS-MIB-upsEstimatedChargeRemaining-0.rrd N:100 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.43] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 100) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24683.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24683.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.43] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00127697s] Checking (snmp) runtime Runtime On Battery Array ( [sensor_id] => 24685 [sensor_deleted] => 0 [sensor_class] => runtime [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.2.2.0 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsSecondsOnBattery [sensor_index] => 0 [sensor_type] => SOCOMECUPS-MIB-upsSecondsOnBattery [sensor_descr] => Runtime On Battery [sensor_unit] => [sensor_multiplier] => 0.0166667 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.2.2.0 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-runtime-SOCOMECUPS-MIB-upsSecondsOnBattery-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-runtime-SOCOMECUPS-MIB-upsSecondsOnBattery-0.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.43] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24685.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24685.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.43] RRD_STATUS[TRUE]  Checking (snmp) runtime Battery Runtime Remaining Array ( [sensor_id] => 24684 [sensor_deleted] => 0 [sensor_class] => runtime [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.2.3.0 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsEstimatedMinutesRemaining [sensor_index] => 0 [sensor_type] => SOCOMECUPS-MIB-upsEstimatedMinutesRemaining [sensor_descr] => Battery Runtime Remaining [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => 5 [sensor_limit_low_warn] => 8 [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 17.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.2.3.0 = 17 Array ( [sensor_value] => 17 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-runtime-SOCOMECUPS-MIB-upsEstimatedMinutesRemaining-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-runtime-SOCOMECUPS-MIB-upsEstimatedMinutesRemaining-0.rrd N:17 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.44] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 17) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24684.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24684.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.44] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00178099s] Checking (snmp) frequency Input Array ( [sensor_id] => 24687 [sensor_deleted] => 0 [sensor_class] => frequency [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.2.0 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputFrequency [sensor_index] => 0 [sensor_type] => SOCOMECUPS-MIB-upsInputFrequency [sensor_descr] => Input [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 52.395 [sensor_limit_warn] => [sensor_limit_low] => 47.405 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 49.9000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.2.0 = 499 Array ( [sensor_value] => 499 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS-MIB-upsInputFrequency-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS-MIB-upsInputFrequency-0.rrd N:49.9 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.44] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 49.9) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24687.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24687.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.00 r:0.44] RRD_STATUS[TRUE]  Checking (snmp) frequency Output Array ( [sensor_id] => 24694 [sensor_deleted] => 0 [sensor_class] => frequency [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.2.0 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputFrequency [sensor_index] => 0 [sensor_type] => SOCOMECUPS-MIB-upsOutputFrequency [sensor_descr] => Output [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 52.5 [sensor_limit_warn] => [sensor_limit_low] => 47.5 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 50.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.2.0 = 500 Array ( [sensor_value] => 500 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS-MIB-upsOutputFrequency-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS-MIB-upsOutputFrequency-0.rrd N:50 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.45] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 50) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24694.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24694.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.45] RRD_STATUS[TRUE]  Checking (snmp) frequency Bypass Array ( [sensor_id] => 27494 [sensor_deleted] => 0 [sensor_class] => frequency [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.5.1.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsBypassFrequency [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsBypassFrequency [sensor_descr] => Bypass [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 52.5 [sensor_limit_warn] => [sensor_limit_low] => 47.5 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 50.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.5.1.0 = 500 Array ( [sensor_value] => 500 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS7-MIB-upsBypassFrequency-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-frequency-SOCOMECUPS7-MIB-upsBypassFrequency-0.rrd N:50 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.45] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 50) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27494.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27494.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.45] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00154614s] Checking (snmp) voltage Input Phase 1 Array ( [sensor_id] => 24688 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputVoltage [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsInputVoltage [sensor_descr] => Input Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 265.65 [sensor_limit_warn] => [sensor_limit_low] => 196.35 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 232.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.1 = 2320 Array ( [sensor_value] => 2320 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-1.rrd N:232 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 232) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24688.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24688.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking (snmp) voltage Input Phase 2 Array ( [sensor_id] => 24689 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputVoltage [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsInputVoltage [sensor_descr] => Input Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 266.8 [sensor_limit_warn] => [sensor_limit_low] => 197.2 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 233.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.2 = 2320 Array ( [sensor_value] => 2320 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-2.rrd N:232 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 232) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24689.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24689.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking (snmp) voltage Input Phase 3 Array ( [sensor_id] => 24690 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputVoltage [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsInputVoltage [sensor_descr] => Input Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 265.65 [sensor_limit_warn] => [sensor_limit_low] => 196.35 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 232.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.2.3 = 2320 Array ( [sensor_value] => 2320 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsInputVoltage-3.rrd N:232 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 232) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24690.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24690.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking (snmp) voltage Output Phase 1 Array ( [sensor_id] => 24695 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputVoltage [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsOutputVoltage [sensor_descr] => Output Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 265.65 [sensor_limit_warn] => [sensor_limit_low] => 196.35 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 231.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.1 = 2310 Array ( [sensor_value] => 2310 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-1.rrd N:231 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 231) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24695.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24695.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking (snmp) voltage Output Phase 2 Array ( [sensor_id] => 24696 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputVoltage [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsOutputVoltage [sensor_descr] => Output Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 264.5 [sensor_limit_warn] => [sensor_limit_low] => 195.5 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 230.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.2 = 2300 Array ( [sensor_value] => 2300 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-2.rrd N:230 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.46] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 230) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24696.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24696.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking (snmp) voltage Output Phase 3 Array ( [sensor_id] => 24697 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputVoltage [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsOutputVoltage [sensor_descr] => Output Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 264.5 [sensor_limit_warn] => [sensor_limit_low] => 195.5 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 230.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.2.3 = 2300 Array ( [sensor_value] => 2300 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsOutputVoltage-3.rrd N:230 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 230) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24697.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24697.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking (snmp) voltage Bypass Phase 1 Array ( [sensor_id] => 24708 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassVoltage [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsBypassVoltage [sensor_descr] => Bypass Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 265.65 [sensor_limit_warn] => [sensor_limit_low] => 196.35 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 233.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.1 = 2320 Array ( [sensor_value] => 2320 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-1.rrd N:232 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 232) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24708.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24708.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking (snmp) voltage Bypass Phase 2 Array ( [sensor_id] => 24709 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassVoltage [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsBypassVoltage [sensor_descr] => Bypass Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 265.65 [sensor_limit_warn] => [sensor_limit_low] => 196.35 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 232.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.2 = 2310 Array ( [sensor_value] => 2310 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-2.rrd N:231 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 231) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24709.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24709.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking (snmp) voltage Bypass Phase 3 Array ( [sensor_id] => 24710 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassVoltage [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsBypassVoltage [sensor_descr] => Bypass Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 266.8 [sensor_limit_warn] => [sensor_limit_low] => 197.2 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 233.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.2.3 = 2310 Array ( [sensor_value] => 2310 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS-MIB-upsBypassVoltage-3.rrd N:231 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.47] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 231) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24710.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24710.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.48] RRD_STATUS[TRUE]  Checking (snmp) voltage Battery Array ( [sensor_id] => 27484 [sensor_deleted] => 0 [sensor_class] => voltage [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.2.5.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsBatteryVoltage [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsBatteryVoltage [sensor_descr] => Battery [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 652.05 [sensor_limit_warn] => [sensor_limit_low] => 481.95 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 567.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.2.5.0 = 5670 Array ( [sensor_value] => 5670 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS7-MIB-upsBatteryVoltage-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-voltage-SOCOMECUPS7-MIB-upsBatteryVoltage-0.rrd N:567 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.48] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 567) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27484.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27484.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.48] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00154686s] Checking (snmp) current Input Phase 1 Array ( [sensor_id] => 24691 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputCurrent [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsInputCurrent [sensor_descr] => Input Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.1 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-1.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.49] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24691.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24691.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.49] RRD_STATUS[TRUE]  Checking (snmp) current Input Phase 2 Array ( [sensor_id] => 24692 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputCurrent [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsInputCurrent [sensor_descr] => Input Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.2 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-2.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.49] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24692.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24692.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.49] RRD_STATUS[TRUE]  Checking (snmp) current Input Phase 3 Array ( [sensor_id] => 24693 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsInputCurrent [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsInputCurrent [sensor_descr] => Input Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Input Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.3.3.1.3.3 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsInputCurrent-3.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.49] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24693.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24693.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking (snmp) current Output Phase 1 Array ( [sensor_id] => 24698 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputCurrent [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsOutputCurrent [sensor_descr] => Output Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 106.5 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 70.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.1 = 700 Array ( [sensor_value] => 700 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-1.rrd N:70 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 70) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24698.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24698.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50 OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking (snmp) current Output Phase 2 Array ( [sensor_id] => 24699 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputCurrent [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsOutputCurrent [sensor_descr] => Output Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 94.5 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 63.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.2 = 640 Array ( [sensor_value] => 640 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-2.rrd N:64 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 64) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24699.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24699.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking (snmp) current Output Phase 3 Array ( [sensor_id] => 24700 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputCurrent [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsOutputCurrent [sensor_descr] => Output Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 69 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 47.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.3.3 = 480 Array ( [sensor_value] => 480 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsOutputCurrent-3.rrd N:48 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 48) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24700.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24700.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.50] RRD_STATUS[TRUE]  Checking (snmp) current Bypass Phase 1 Array ( [sensor_id] => 24711 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassCurrent [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsBypassCurrent [sensor_descr] => Bypass Phase 1 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.1 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-1.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24711.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24711.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]  Checking (snmp) current Bypass Phase 2 Array ( [sensor_id] => 24712 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassCurrent [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsBypassCurrent [sensor_descr] => Bypass Phase 2 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.2 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-2.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24712.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24712.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]  Checking (snmp) current Bypass Phase 3 Array ( [sensor_id] => 24713 [sensor_deleted] => 0 [sensor_class] => current [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsBypassCurrent [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsBypassCurrent [sensor_descr] => Bypass Phase 3 [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Bypass Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 0.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.5.3.1.3.3 = 0 Array ( [sensor_value] => 0 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-current-SOCOMECUPS-MIB-upsBypassCurrent-3.rrd N:0 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value empty: '0') NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24713.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24713.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.51] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00163698s] Checking (snmp) load Output Phase 1 Array ( [sensor_id] => 24701 [sensor_deleted] => 0 [sensor_class] => load [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.1 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputPercentLoad [sensor_index] => 1 [sensor_type] => SOCOMECUPS-MIB-upsOutputPercentLoad [sensor_descr] => Output Phase 1 [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 19.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.1 = 19 Array ( [sensor_value] => 19 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-1.rrd N:19 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 19) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24701.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24701.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking (snmp) load Output Phase 2 Array ( [sensor_id] => 24702 [sensor_deleted] => 0 [sensor_class] => load [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.2 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputPercentLoad [sensor_index] => 2 [sensor_type] => SOCOMECUPS-MIB-upsOutputPercentLoad [sensor_descr] => Output Phase 2 [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 17.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.2 = 17 Array ( [sensor_value] => 17 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-2.rrd N:17 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 17) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24702.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24702.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking (snmp) load Output Phase 3 Array ( [sensor_id] => 24703 [sensor_deleted] => 0 [sensor_class] => load [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.3 [sensor_mib] => SOCOMECUPS-MIB [sensor_object] => upsOutputPercentLoad [sensor_index] => 3 [sensor_type] => SOCOMECUPS-MIB-upsOutputPercentLoad [sensor_descr] => Output Phase 3 [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 13.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1726220900 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.1.1.4.4.1.4.3 = 13 Array ( [sensor_value] => 13 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS-MIB-upsOutputPercentLoad-3.rrd N:13 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 13) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-24703.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-24703.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking (snmp) load Output Total Array ( [sensor_id] => 27493 [sensor_deleted] => 0 [sensor_class] => load [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.7.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputLoadRate [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsOutputLoadRate [sensor_descr] => Output Total [sensor_unit] => [sensor_multiplier] => 1 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 19.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.7.0 = 19 Array ( [sensor_value] => 19 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS7-MIB-upsOutputLoadRate-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-load-SOCOMECUPS7-MIB-upsOutputLoadRate-0.rrd N:19 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 19) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27493.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27493.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.53] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00133514s] Checking (snmp) temperature Ambient Array ( [sensor_id] => 27483 [sensor_deleted] => 0 [sensor_class] => temperature [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.2.7.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsAmbientTemperature [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsAmbientTemperature [sensor_descr] => Ambient [sensor_unit] => [sensor_multiplier] => 0.1 [sensor_limit] => 36.8 [sensor_limit_warn] => [sensor_limit_low] => 0 [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 23.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.2.7.0 = 230 Array ( [sensor_value] => 230 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-temperature-SOCOMECUPS7-MIB-upsAmbientTemperature-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-temperature-SOCOMECUPS7-MIB-upsAmbientTemperature-0.rrd N:23 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.54] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 23) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27483.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27483.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.54] RRD_STATUS[TRUE]  Checking alert 15 associated by Testing: sensor_event warning (value: ok) ERROR: Unknown condition 'warning' passed to test_condition(). NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-15-sensor-27483.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-15-sensor-27483.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.54] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'apower' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00162601s] Checking (snmp) apower Output Phase 1 Array ( [sensor_id] => 27485 [sensor_deleted] => 0 [sensor_class] => apower [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.1 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKva [sensor_index] => 1 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKva [sensor_descr] => Output Phase 1 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 16000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.1 = 160 Array ( [sensor_value] => 160 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-1.rrd N:16000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 16000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27485.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27485.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking (snmp) apower Output Phase 2 Array ( [sensor_id] => 27486 [sensor_deleted] => 0 [sensor_class] => apower [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.2 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKva [sensor_index] => 2 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKva [sensor_descr] => Output Phase 2 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 14000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.2 = 140 Array ( [sensor_value] => 140 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-2.rrd N:14000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 14000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27486.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27486.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking (snmp) apower Output Phase 3 Array ( [sensor_id] => 27487 [sensor_deleted] => 0 [sensor_class] => apower [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.3 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKva [sensor_index] => 3 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKva [sensor_descr] => Output Phase 3 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 11000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.5.3 = 110 Array ( [sensor_value] => 110 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputKva-3.rrd N:11000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 11000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27487.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27487.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.55] RRD_STATUS[TRUE]  Checking (snmp) apower Output Total Array ( [sensor_id] => 27491 [sensor_deleted] => 0 [sensor_class] => apower [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.5.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputGlobalkVA [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsOutputGlobalkVA [sensor_descr] => Output Total [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 40000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.5.0 = 410 Array ( [sensor_value] => 410 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputGlobalkVA-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-apower-SOCOMECUPS7-MIB-upsOutputGlobalkVA-0.rrd N:41000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.56] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 41000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27491.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27491.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.56] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '855' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00140309s] Checking (snmp) power Output Phase 1 Array ( [sensor_id] => 27488 [sensor_deleted] => 0 [sensor_class] => power [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.1 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKw [sensor_index] => 1 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKw [sensor_descr] => Output Phase 1 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => 22500 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 1 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 16000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.1 = 150 Array ( [sensor_value] => 150 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-1.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-1.rrd N:15000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.56] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 15000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27488.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27488.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking (snmp) power Output Phase 2 Array ( [sensor_id] => 27489 [sensor_deleted] => 0 [sensor_class] => power [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.2 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKw [sensor_index] => 2 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKw [sensor_descr] => Output Phase 2 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => 21000 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 2 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 14000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.2 = 140 Array ( [sensor_value] => 140 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-2.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-2.rrd N:14000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 14000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27489.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27489.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking (snmp) power Output Phase 3 Array ( [sensor_id] => 27490 [sensor_deleted] => 0 [sensor_class] => power [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.3 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputKw [sensor_index] => 3 [sensor_type] => SOCOMECUPS7-MIB-upsOutputKw [sensor_descr] => Output Phase 3 [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => 15000 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => phase [measured_entity] => [measured_entity_label] => Output Phase 3 [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 10000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.4.1.6.3 = 100 Array ( [sensor_value] => 100 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-3.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputKw-3.rrd N:10000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 10000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27490.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27490.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking (snmp) power Output Total Array ( [sensor_id] => 27492 [sensor_deleted] => 0 [sensor_class] => power [device_id] => 855 [poller_type] => snmp [sensor_oid] => .1.3.6.1.4.1.4555.1.1.7.1.4.6.0 [sensor_mib] => SOCOMECUPS7-MIB [sensor_object] => upsOutputGlobalkW [sensor_index] => 0 [sensor_type] => SOCOMECUPS7-MIB-upsOutputGlobalkW [sensor_descr] => Output Total [sensor_unit] => [sensor_multiplier] => 100 [sensor_limit] => 58500 [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_custom_limit] => 0 [entPhysicalIndex] => [entPhysicalClass] => [entPhysicalIndex_measured] => [measured_class] => [measured_entity] => [measured_entity_label] => [sensor_ignore] => 0 [sensor_disable] => 0 [sensor_value] => 40000.0000000000000000 [sensor_event] => ok [sensor_status] => [sensor_polled] => 1763740214 [sensor_last_change] => 1754407913 ) value taken from oid_cache: .1.3.6.1.4.1.4555.1.1.7.1.4.6.0 = 390 Array ( [sensor_value] => 390 ) RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputGlobalkW-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/sensor-power-SOCOMECUPS7-MIB-upsOutputGlobalkW-0.rrd N:39000 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  Checking alert 13 associated by DEBUG get_metric_tagged_value(): replaced sensor_value value @sensor_limit sensor_value less @sensor_limit_low with from entity. Testing: sensor_value greater (value: 39000) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-13-sensor-27492.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-13-sensor-27492.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.57] RRD_STATUS[TRUE]  MultiUpdate sensors DB. SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`) VALUES ('24683','100','ok','','1726220900','1763740310'),('24685','0','ok','','1726220900','1763740310'),('24684','17','ok','','1726220900','1763740310'),('24687','49.9','ok','','1726220900','1763740310'),('24694','50','ok','','1726220900','1763740310'),('27494','50','ok','','1754407913','1763740310'),('24688','232','ok','','1726220900','1763740310'),('24689','232','ok','','1726220900','1763740310'),('24690','232','ok','','1726220900','1763740310'),('24695','231','ok','','1726220900','1763740310'),('24696','230','ok','','1726220900','1763740310'),('24697','230','ok','','1726220900','1763740310'),('24708','232','ok','','1726220900','1763740310'),('24709','231','ok','','1726220900','1763740310'),('24710','231','ok','','1726220900','1763740310'),('27484','567','ok','','1754407913','1763740310'),('24691','0','ok','','1726220900','1763740310'),('24692','0','ok','','1726220900','1763740310'),('24693','0','ok','','1726220900','1763740310'),('24698','70','ok','','1726220900','1763740310'),('24699','64','ok','','1726220900','1763740310'),('24700','48','ok','','1726220900','1763740310'),('24711','0','ok','','1726220900','1763740310'),('24712','0','ok','','1726220900','1763740310'),('24713','0','ok','','1726220900','1763740310'),('24701','19','ok','','1726220900','1763740310'),('24702','17','ok','','1726220900','1763740310'),('24703','13','ok','','1726220900','1763740310'),('27493','19','ok','','1754407913','1763740310'),('27483','23','ok','','1754407913','1763740310'),('27485','16000','ok','','1754407913','1763740310'),('27486','14000','ok','','1754407913','1763740310'),('27487','11000','ok','','1754407913','1763740310'),('27491','41000','ok','','1754407913','1763740310'),('27488','15000','ok','','1754407913','1763740310'),('27489','14000','ok','','1754407913','1763740310'),('27490','10000','ok','','1754407913','1763740310'),('27492','39000','ok','','1754407913','1763740310') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)] SQL RUNTIME[0.01292086s] +---------------------------+-------------+---------------------------------------------+--------+----------+-------+---------------------+ | Descr | Class | Type | Origin | Value | Event | Last Changed | +---------------------------+-------------+---------------------------------------------+--------+----------+-------+---------------------+ | Battery Charge Remaining | capacity | SOCOMECUPS-MIB-upsEstimatedChargeRemaining | snmp | 100% | ok | 13.09.2024 09:48:20 | | Runtime On Battery | runtime | SOCOMECUPS-MIB-upsSecondsOnBattery | snmp | 0min | ok | 13.09.2024 09:48:20 | | Battery Runtime Remaining | runtime | SOCOMECUPS-MIB-upsEstimatedMinutesRemaining | snmp | 17min | ok | 13.09.2024 09:48:20 | | Input | frequency | SOCOMECUPS-MIB-upsInputFrequency | snmp | 49.9Hz | ok | 13.09.2024 09:48:20 | | Output | frequency | SOCOMECUPS-MIB-upsOutputFrequency | snmp | 50Hz | ok | 13.09.2024 09:48:20 | | Bypass | frequency | SOCOMECUPS7-MIB-upsBypassFrequency | snmp | 50Hz | ok | 05.08.2025 15:31:53 | | Input Phase 1 | voltage | SOCOMECUPS-MIB-upsInputVoltage | snmp | 232V | ok | 13.09.2024 09:48:20 | | Input Phase 2 | voltage | SOCOMECUPS-MIB-upsInputVoltage | snmp | 232V | ok | 13.09.2024 09:48:20 | | Input Phase 3 | voltage | SOCOMECUPS-MIB-upsInputVoltage | snmp | 232V | ok | 13.09.2024 09:48:20 | | Output Phase 1 | voltage | SOCOMECUPS-MIB-upsOutputVoltage | snmp | 231V | ok | 13.09.2024 09:48:20 | | Output Phase 2 | voltage | SOCOMECUPS-MIB-upsOutputVoltage | snmp | 230V | ok | 13.09.2024 09:48:20 | | Output Phase 3 | voltage | SOCOMECUPS-MIB-upsOutputVoltage | snmp | 230V | ok | 13.09.2024 09:48:20 | | Bypass Phase 1 | voltage | SOCOMECUPS-MIB-upsBypassVoltage | snmp | 232V | ok | 13.09.2024 09:48:20 | | Bypass Phase 2 | voltage | SOCOMECUPS-MIB-upsBypassVoltage | snmp | 231V | ok | 13.09.2024 09:48:20 | | Bypass Phase 3 | voltage | SOCOMECUPS-MIB-upsBypassVoltage | snmp | 231V | ok | 13.09.2024 09:48:20 | | Battery | voltage | SOCOMECUPS7-MIB-upsBatteryVoltage | snmp | 567V | ok | 05.08.2025 15:31:53 | | Input Phase 1 | current | SOCOMECUPS-MIB-upsInputCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Input Phase 2 | current | SOCOMECUPS-MIB-upsInputCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Input Phase 3 | current | SOCOMECUPS-MIB-upsInputCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Output Phase 1 | current | SOCOMECUPS-MIB-upsOutputCurrent | snmp | 70A | ok | 13.09.2024 09:48:20 | | Output Phase 2 | current | SOCOMECUPS-MIB-upsOutputCurrent | snmp | 64A | ok | 13.09.2024 09:48:20 | | Output Phase 3 | current | SOCOMECUPS-MIB-upsOutputCurrent | snmp | 48A | ok | 13.09.2024 09:48:20 | | Bypass Phase 1 | current | SOCOMECUPS-MIB-upsBypassCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Bypass Phase 2 | current | SOCOMECUPS-MIB-upsBypassCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Bypass Phase 3 | current | SOCOMECUPS-MIB-upsBypassCurrent | snmp | 0A | ok | 13.09.2024 09:48:20 | | Output Phase 1 | load | SOCOMECUPS-MIB-upsOutputPercentLoad | snmp | 19% | ok | 13.09.2024 09:48:20 | | Output Phase 2 | load | SOCOMECUPS-MIB-upsOutputPercentLoad | snmp | 17% | ok | 13.09.2024 09:48:20 | | Output Phase 3 | load | SOCOMECUPS-MIB-upsOutputPercentLoad | snmp | 13% | ok | 13.09.2024 09:48:20 | | Output Total | load | SOCOMECUPS7-MIB-upsOutputLoadRate | snmp | 19% | ok | 05.08.2025 15:31:53 | | Ambient | temperature | SOCOMECUPS7-MIB-upsAmbientTemperature | snmp | 23°C | ok | 05.08.2025 15:31:53 | | Output Phase 1 | apower | SOCOMECUPS7-MIB-upsOutputKva | snmp | 16000VA | ok | 05.08.2025 15:31:53 | | Output Phase 2 | apower | SOCOMECUPS7-MIB-upsOutputKva | snmp | 14000VA | ok | 05.08.2025 15:31:53 | | Output Phase 3 | apower | SOCOMECUPS7-MIB-upsOutputKva | snmp | 11000VA | ok | 05.08.2025 15:31:53 | | Output Total | apower | SOCOMECUPS7-MIB-upsOutputGlobalkVA | snmp | 41000VA | ok | 05.08.2025 15:31:53 | | Output Phase 1 | power | SOCOMECUPS7-MIB-upsOutputKw | snmp | 15000W | ok | 05.08.2025 15:31:53 | | Output Phase 2 | power | SOCOMECUPS7-MIB-upsOutputKw | snmp | 14000W | ok | 05.08.2025 15:31:53 | | Output Phase 3 | power | SOCOMECUPS7-MIB-upsOutputKw | snmp | 10000W | ok | 05.08.2025 15:31:53 | | Output Total | power | SOCOMECUPS7-MIB-upsOutputGlobalkW | snmp | 39000W | ok | 05.08.2025 15:31:53 | +---------------------------+-------------+---------------------------------------------+--------+----------+-------+---------------------+  o Module time  0.3194s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-sensors.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-sensors.rrd N:0.3194 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.63] RRD_STATUS[TRUE]   including: includes/polling/status.inc.php ##### Module Start: status #####   SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '855' AND `status_deleted` = '0';] SQL RUNTIME[0.00091195s]  o Status Count  2 SQL[SELECT DISTINCT `status_oid` FROM `status` WHERE `device_id` = '855' AND `status_deleted` = '0' AND `poller_type` = 'snmp'] SQL RUNTIME[0.00085211s]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' .1.3.6.1.4.1.4555.1.1.7.1.2.1.0 .1.3.6.1.4.1.4555.1.1.7.1.4.1.0]  CMD EXITCODE[0] CMD RUNTIME[0.0228s] CMD EXITDELAY[5ms] STDOUT[ .1.3.6.1.4.1.4555.1.1.7.1.2.1.0 = 2 .1.3.6.1.4.1.4555.1.1.7.1.4.1.0 = 3 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `status` WHERE `device_id` = '855' AND `status_deleted` = '0' ORDER BY `status_oid`] SQL RUNTIME[0.00131798s] Checking (snmp) Battery Status value taken from oid_cache RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/status-SOCOMECUPS7-MIB-upsBatteryStatus-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/status-SOCOMECUPS7-MIB-upsBatteryStatus-0.rrd N:2 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]  Checking alert 12 associated by Testing: status_event equals warn (value: ok) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-12-status-20406.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-12-status-20406.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]  Checking (snmp) Output Source value taken from oid_cache RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/status-SOCOMECUPS7-MIB-upsOutputSource-0.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/status-SOCOMECUPS7-MIB-upsOutputSource-0.rrd N:3 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]  Checking alert 12 associated by Testing: status_event equals warn (value: ok) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-12-status-20407.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-12-status-20407.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]  MultiUpdate status DB. SQL[INSERT INTO `status` (`status_id`,`status_value`,`status_name`,`status_event`,`status_last_change`,`status_polled`) VALUES ('20406','2','batteryNormal','ok','1754407913','1763740310'),('20407','3','onInverter','ok','1754407913','1763740310') ON DUPLICATE KEY UPDATE `status_id`=VALUES(`status_id`),`status_value`=VALUES(`status_value`),`status_name`=VALUES(`status_name`),`status_event`=VALUES(`status_event`),`status_last_change`=VALUES(`status_last_change`),`status_polled`=VALUES(`status_polled`)] SQL RUNTIME[0.00162697s] +----------------+------------------+-------+--------+---------------+--------+---------------------+ | Descr | Type | Index | Origin | Value | Status | Last Changed | +----------------+------------------+-------+--------+---------------+--------+---------------------+ | Battery Status | upsBatteryStatus | 0 | snmp | batteryNormal | ok | 05.08.2025 15:31:53 | | Output Source | upsOutputSource | 0 | snmp | onInverter | ok | 05.08.2025 15:31:53 | +----------------+------------------+-------+--------+---------------+--------+---------------------+  o Module time  0.0567s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-status.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-status.rrd N:0.0567 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.69] RRD_STATUS[TRUE]   including: includes/polling/counter.inc.php ##### Module Start: counter #####   SQL[SELECT EXISTS (SELECT 1 FROM `counters` WHERE `device_id` = '855' AND `counter_deleted` = '0')] SQL RUNTIME[0.00052905s]  o Module time  0.0037s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-counter.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-counter.rrd N:0.0037 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.70] RRD_STATUS[TRUE]   including: includes/polling/processors.inc.php ##### Module Start: processors #####   SQL[SELECT `processor_oid` FROM `processors` WHERE `device_id` = '855' AND `processor_oid` REGEXP '^\\.?[0-9]+(\\.[0-9]+)+$' AND `processor_type` != 'wmi'] SQL RUNTIME[0.00064588s]  SQL[SELECT * FROM `processors` WHERE `device_id` = '855'] SQL RUNTIME[0.00085211s]  o Module time  0.0079s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-processors.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-processors.rrd N:0.0079 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.70] RRD_STATUS[TRUE]   including: includes/polling/mempools.inc.php ##### Module Start: mempools #####   SQL[SELECT * FROM `mempools` WHERE `device_id` = '855'] SQL RUNTIME[0.00071692s]  o Module time  0.0042s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-mempools.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-mempools.rrd N:0.0042 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.71] RRD_STATUS[TRUE]   including: includes/polling/storage.inc.php ##### Module Start: storage #####   SQL[SELECT `storage_mib`, `storage_object`, `storage_hc`, GROUP_CONCAT(`storage_index` SEPARATOR ',') AS `indexes` FROM `storage` WHERE `device_id` = '855' GROUP BY `storage_mib`, `storage_object`, `storage_hc`] SQL RUNTIME[0.00072217s]  SQL[SELECT * FROM `storage` WHERE `device_id` = '855'] SQL RUNTIME[0.00082922s]  o Module time  0.0152s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-storage.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-storage.rrd N:0.0152 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:0.73] RRD_STATUS[TRUE]   including: includes/polling/ipSystemStats.inc.php ##### Module Start: ipSystemStats #####   o Collecting  ipSystemStats CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' ipSystemStats]  CMD EXITCODE[0] CMD RUNTIME[0.0277s] STDOUT[ ipSystemStatsTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'IP-MIB' AND `oid` = 'ipSystemStats';] SQL RUNTIME[0.00110102s]  SQL[UPDATE `snmp_errors` set `error_count` ='123843',`updated` ='1763740310' WHERE `error_id` = '94657'] SQL RUNTIME[0.00158191s]  o Module time  0.0466s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-ipSystemStats.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-ipSystemStats.rrd N:0.0466 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.77] RRD_STATUS[TRUE]   including: includes/polling/ports.inc.php ##### Module Start: ports #####   SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '855' AND `entity_type` = 'port'] SQL RUNTIME[0.00095201s]  SQL[SELECT * FROM `ports` WHERE `device_id` = '855'] SQL RUNTIME[0.00103688s]  o Caching Oids  Used full table ifEntry/ifXEntry snmpwalk. ifEntry CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' ifEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0247s] STDOUT[ ifEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'IF-MIB' AND `oid` = 'ifEntry';] SQL RUNTIME[0.00086498s]  SQL[UPDATE `snmp_errors` set `error_count` ='123843',`updated` ='1763740310' WHERE `error_id` = '94658'] SQL RUNTIME[0.00154209s] ifXEntry CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' ifXEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0262s] STDOUT[ ifXEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'IF-MIB' AND `oid` = 'ifXEntry';] SQL RUNTIME[0.00099802s]  SQL[UPDATE `snmp_errors` set `error_count` ='123842',`updated` ='1763740310' WHERE `error_id` = '94659'] SQL RUNTIME[0.00165892s]   o ADSL-LINE-MIB    o EtherLike-MIB    o Q-BRIDGE-MIB   CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' dot1dBasePortIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0265s] STDOUT[ dot1dBasePortIfIndex = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'BRIDGE-MIB' AND `oid` = 'dot1dBasePortIfIndex';] SQL RUNTIME[0.00120497s]  SQL[UPDATE `snmp_errors` set `error_count` ='123843',`updated` ='1763740310' WHERE `error_id` = '94660'] SQL RUNTIME[0.00170803s]  CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' dot1qPvid]  CMD EXITCODE[0] CMD RUNTIME[0.0323s] STDOUT[ dot1qPvid = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'Q-BRIDGE-MIB' AND `oid` = 'dot1qPvid';] SQL RUNTIME[0.001055s]  SQL[UPDATE `snmp_errors` set `error_count` ='123843',`updated` ='1763740310' WHERE `error_id` = '94661'] SQL RUNTIME[0.00161219s]  CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Irh -OQUsx --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' dot1qVlanStaticUntaggedPorts]  CMD EXITCODE[0] CMD RUNTIME[0.0299s] STDOUT[ dot1qVlanStaticUntaggedPorts = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'Q-BRIDGE-MIB' AND `oid` = 'dot1qVlanStaticUntaggedPorts';] SQL RUNTIME[0.00085998s]  SQL[UPDATE `snmp_errors` set `error_count` ='123843',`updated` ='1763740311',`snmp_options` ='-OQUsx --hexOutputLength=0' WHERE `error_id` = '94662'] SQL RUNTIME[0.00170779s] dot1qVlanStaticUntaggedPorts print_cli_table() argument should be an array. [[IP-MIB]] o IP-MIB    o Module time  0.2423s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-ports.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-ports.rrd N:0.2423 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:1.02] RRD_STATUS[TRUE]   including: includes/polling/printersupplies.inc.php ##### Module Start: printersupplies #####   SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '855'] SQL RUNTIME[0.00058889s]  o Module time  0.0038s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-printersupplies.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-printersupplies.rrd N:0.0038 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:1.02] RRD_STATUS[TRUE]   including: includes/polling/ucd-diskio.inc.php ##### Module Start: ucd-diskio #####   SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '855'] SQL RUNTIME[0.00035596s]  o Module time  0.0035s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-ucd-diskio.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-ucd-diskio.rrd N:0.0035 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.001s] RRD STDOUT[OK u:0.02 s:0.01 r:1.03] RRD_STATUS[TRUE]   including: includes/polling/loadbalancer.inc.php ##### Module Start: loadbalancer #####   o Module time  0.0002s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-loadbalancer.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-loadbalancer.rrd N:0.0002 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.03] RRD_STATUS[TRUE]   including: includes/polling/entity-physical.inc.php ##### Module Start: entity-physical #####   o Module time  0.0001s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-entity-physical.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-entity-physical.rrd N:0.0001 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.03] RRD_STATUS[TRUE]   including: includes/polling/fdb-table.inc.php ##### Module Start: fdb-table #####   SQL[SELECT `ifIndex`, `port_id`, `ifDescr`, `port_label_short` FROM `ports` WHERE `device_id` = '855'] SQL RUNTIME[0.00080013s]  SQL[SELECT COUNT(*) FROM `vlans_fdb` WHERE `device_id` = '855' AND `deleted` = '1' AND `fdb_last_change` < 1761148310] SQL RUNTIME[0.00077891s] Deleting 0 FDB entries older than 30d. SQL[DELETE FROM `vlans_fdb` WHERE `device_id` = '855' AND `deleted` = '1' AND `fdb_last_change` < 1761148310] SQL RUNTIME[0.00070095s]  SQL[SELECT * FROM `vlans_fdb` WHERE `device_id` = '855'] SQL RUNTIME[0.00071597s]  CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ir -OQUsb -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' dot1qTpFdbEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0347s] STDOUT[ dot1qTpFdbEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpwalk' AND `mib` = 'Q-BRIDGE-MIB' AND `oid` = 'dot1qTpFdbEntry';] SQL RUNTIME[0.0009079s]  SQL[UPDATE `snmp_errors` set `error_count` ='123842',`updated` ='1763740311' WHERE `error_id` = '94663'] SQL RUNTIME[0.00715208s]  o Module time  0.0719s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-fdb-table.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-fdb-table.rrd N:0.0719 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.10] RRD_STATUS[TRUE]   including: includes/polling/graphs.inc.php ##### Module Start: graphs #####   o HOST-RESOURCES-MIB    o HOST-RESOURCES-MIB  hrSystemProcesses SQL[SELECT `object` FROM `devices_mibs` WHERE `device_id` = '855' AND `use` = 'oid' AND `disabled` = '1' AND `mib` = 'HOST-RESOURCES-MIB'] SQL RUNTIME[0.00094414s]  CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' hrSystemProcesses.0]  CMD EXITCODE[0] CMD RUNTIME[0.0244s] STDOUT[ hrSystemProcesses.0 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemProcesses.0';] SQL RUNTIME[0.000947s]  SQL[UPDATE `snmp_errors` set `error_count` ='48066',`updated` ='1763740311' WHERE `error_id` = '102080'] SQL RUNTIME[0.00284815s] SNMP STATUS[FALSE]  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped. hrSystemNumUsers CMD[/usr/bin/snmpget -v2c -c *** -Pud -Ir -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups24-datacenter.cri.ulm':'161' hrSystemNumUsers.0]  CMD EXITCODE[0] CMD RUNTIME[0.0229s] CMD EXITDELAY[5ms] STDOUT[ hrSystemNumUsers.0 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '855' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemNumUsers.0';] SQL RUNTIME[0.00198221s]  SQL[UPDATE `snmp_errors` set `error_count` ='48067',`updated` ='1763740311' WHERE `error_id` = '102081'] SQL RUNTIME[0.00153494s] SNMP STATUS[FALSE]  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped.  o Module time  0.0849s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-graphs.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-graphs.rrd N:0.0849 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.02 s:0.01 r:1.19] RRD_STATUS[TRUE]   including: includes/polling/oids.inc.php ##### Module Start: oids #####   SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '855'] SQL RUNTIME[0.00114202s]  o Module time  0.0116s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-oids.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-oids.rrd N:0.0116 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.20] RRD_STATUS[TRUE]   including: includes/polling/probes.inc.php ##### Module Start: probes #####   SQL[SELECT * FROM `probes` WHERE `device_id` = '855'] SQL RUNTIME[0.00066996s]  o Module time  0.005s RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermodule-probes.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermodule-probes.rrd N:0.005 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.21] RRD_STATUS[TRUE]   ##### ups24-datacenter.cri.ulm [855] completed poller modules at 2025-11-21 15:51:51 #####   o Graphs [checked]  availability, ping, ping_snmp, uptime, capacity, runtime, frequency, voltage, current, load, temperature, apower, power, poller_perf,pollersnmp_count, pollersnmp_times, pollersnmp_errors_count, pollersnmp_errors_times, pollerdb_count, pollerdb_times,pollermemory_perf  o Poller time  1.2179 seconds SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '855';] SQL RUNTIME[0.00071383s] RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-poller.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-poller.rrd N:1.2179 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.22] RRD_STATUS[TRUE]  Updating ups24-datacenter.cri.ulm - Array ( [uptime] => 14518579 [last_polled] => Array ( [0] => NOW() ) [last_polled_timetaken] => 1.2179 [device_state] => a:5:{s:15:"poller_mod_perf";a:18:{s:6:"system";d:0.1762;s:2:"os";d:0.0634;s:7:"sensors";d:0.3194;s:6:"status";d:0.0567;s:7:"counter";d:0.0037;s:10:"processors";d:0.0079;s:8:"mempools";d:0.0042;s:7:"storage";d:0.0152;s:13:"ipSystemStats";d:0.0466;s:5:"ports";d:0.2423;s:15:"printersupplies";d:0.0038;s:10:"ucd-diskio";d:0.0035;s:12:"loadbalancer";d:0.0002;s:15:"entity-physical";d:0.0001;s:9:"fdb-table";d:0.0719;s:6:"graphs";d:0.0849;s:4:"oids";d:0.0116;s:6:"probes";d:0.005;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.08016419410705566;s:13:"EtherLike-MIB";d:0.00010895729064941406;s:12:"Q-BRIDGE-MIB";d:0.14347386360168457;s:6:"IP-MIB";d:0.00020503997802734375;}s:14:"poller_history";a:288:{i:1763740310;d:1.2179;i:1763740214;d:0.7751;i:1763739910;d:0.7475;i:1763739581;d:0.7513;i:1763739312;d:0.7649;i:1763739026;d:0.7465;i:1763738740;d:0.7297;i:1763738497;d:0.7223;i:1763738155;d:0.7403;i:1763737783;d:0.7302;i:1763737514;d:0.7323;i:1763737201;d:0.8738;i:1763736893;d:0.778;i:1763736605;d:0.7297;i:1763736291;d:0.7021;i:1763736013;d:0.7834;i:1763735712;d:0.7541;i:1763735415;d:0.7911;i:1763735132;d:0.8034;i:1763734862;d:0.807;i:1763734529;d:0.7104;i:1763734249;d:0.707;i:1763733947;d:0.6838;i:1763733649;d:0.7483;i:1763733325;d:0.764;i:1763733035;d:0.8226;i:1763732711;d:0.7278;i:1763732415;d:0.7765;i:1763732108;d:0.7274;i:1763731789;d:0.735;i:1763731509;d:0.788;i:1763731234;d:0.753;i:1763730911;d:0.7166;i:1763730648;d:0.7399;i:1763730320;d:0.7845;i:1763730019;d:0.757;i:1763729731;d:0.7896;i:1763729419;d:0.7818;i:1763729130;d:0.8183;i:1763728821;d:0.8436;i:1763728527;d:0.7482;i:1763728212;d:0.7507;i:1763727948;d:0.7419;i:1763727673;d:0.7309;i:1763727361;d:0.7031;i:1763727050;d:0.7983;i:1763726739;d:0.7606;i:1763726426;d:0.7904;i:1763726039;d:0.7285;i:1763725854;d:0.7083;i:1763725551;d:0.7406;i:1763725276;d:0.7662;i:1763724946;d:0.7622;i:1763724670;d:5.753;i:1763724351;d:0.6997;i:1763724074;d:0.7733;i:1763723756;d:0.7261;i:1763723446;d:0.7323;i:1763723138;d:0.7693;i:1763722797;d:0.7134;i:1763722496;d:0.7603;i:1763722203;d:0.7889;i:1763721917;d:0.7394;i:1763721626;d:0.772;i:1763721321;d:0.7445;i:1763721024;d:0.7656;i:1763720749;d:0.7123;i:1763720493;d:0.7416;i:1763720188;d:0.7653;i:1763719917;d:0.7505;i:1763719582;d:0.712;i:1763719254;d:0.7752;i:1763718980;d:0.7677;i:1763718686;d:0.7732;i:1763718432;d:0.7741;i:1763718205;d:0.7073;i:1763718051;d:0.7221;i:1763717758;d:0.7664;i:1763717244;d:0.7196;i:1763717032;d:0.7559;i:1763716731;d:0.7991;i:1763716257;d:0.7177;i:1763715955;d:0.6848;i:1763715611;d:0.7924;i:1763715317;d:0.737;i:1763715008;d:0.7115;i:1763714680;d:0.7378;i:1763714444;d:0.7448;i:1763714134;d:0.7181;i:1763713814;d:0.7976;i:1763713518;d:0.6957;i:1763713204;d:0.7721;i:1763712940;d:0.7571;i:1763712568;d:0.6918;i:1763712277;d:0.7583;i:1763711966;d:0.722;i:1763711689;d:0.7773;i:1763711343;d:0.764;i:1763711061;d:0.7537;i:1763710766;d:0.764;i:1763710451;d:0.7419;i:1763710135;d:0.7357;i:1763709834;d:0.7265;i:1763709566;d:0.7121;i:1763709277;d:0.7046;i:1763708969;d:0.7558;i:1763708669;d:0.6979;i:1763708319;d:0.7719;i:1763708023;d:0.7667;i:1763707740;d:0.7434;i:1763707475;d:0.7567;i:1763707146;d:1.7324;i:1763706843;d:0.7553;i:1763706549;d:0.7153;i:1763706261;d:0.708;i:1763705983;d:0.7436;i:1763705664;d:0.7382;i:1763705368;d:0.781;i:1763705076;d:0.7771;i:1763704755;d:0.7577;i:1763704450;d:0.742;i:1763704152;d:0.7385;i:1763703851;d:0.7543;i:1763703531;d:0.7108;i:1763703232;d:0.7178;i:1763702943;d:0.6938;i:1763702647;d:0.7857;i:1763702375;d:0.7523;i:1763702066;d:0.7339;i:1763701768;d:0.7341;i:1763701430;d:0.6838;i:1763701156;d:0.7099;i:1763700831;d:0.7377;i:1763700580;d:0.7072;i:1763700249;d:0.764;i:1763699962;d:0.7221;i:1763699632;d:0.7239;i:1763699302;d:0.7187;i:1763699054;d:0.7202;i:1763698769;d:0.7437;i:1763698482;d:0.77;i:1763698166;d:1.7296;i:1763697840;d:0.7238;i:1763697543;d:0.7615;i:1763697233;d:0.7594;i:1763696942;d:0.7113;i:1763696642;d:0.7198;i:1763696355;d:0.7086;i:1763696045;d:0.7279;i:1763695731;d:0.692;i:1763695444;d:0.7799;i:1763695184;d:0.7339;i:1763694911;d:0.7734;i:1763694563;d:0.7293;i:1763694265;d:0.7396;i:1763693979;d:0.6871;i:1763693646;d:0.7094;i:1763693374;d:0.7309;i:1763693075;d:0.691;i:1763692763;d:0.7887;i:1763692447;d:0.7506;i:1763692151;d:0.7675;i:1763691857;d:0.7611;i:1763691563;d:0.7446;i:1763691292;d:0.7254;i:1763690982;d:0.796;i:1763690672;d:0.738;i:1763690347;d:0.7567;i:1763690047;d:0.7374;i:1763689744;d:0.7688;i:1763689433;d:0.7762;i:1763689168;d:0.7393;i:1763688841;d:0.7447;i:1763688617;d:0.7714;i:1763688271;d:0.7158;i:1763688003;d:0.7699;i:1763687685;d:0.7365;i:1763687359;d:0.704;i:1763687049;d:0.7574;i:1763686746;d:0.7695;i:1763686465;d:0.7411;i:1763686150;d:0.765;i:1763685831;d:0.6993;i:1763685536;d:0.7802;i:1763685230;d:0.7401;i:1763684954;d:0.7637;i:1763684661;d:0.7874;i:1763684361;d:0.7279;i:1763684063;d:0.7121;i:1763683749;d:0.7523;i:1763683480;d:0.7751;i:1763683184;d:0.7468;i:1763682852;d:0.7381;i:1763682576;d:0.7115;i:1763682260;d:0.7423;i:1763681947;d:0.7327;i:1763681651;d:0.8099;i:1763681353;d:0.7447;i:1763681074;d:0.732;i:1763680776;d:0.7382;i:1763680506;d:0.7632;i:1763680174;d:0.7297;i:1763679878;d:0.7171;i:1763679565;d:0.8012;i:1763679264;d:0.7054;i:1763678969;d:0.7358;i:1763678674;d:0.7342;i:1763678349;d:0.7563;i:1763678063;d:0.7981;i:1763677756;d:0.7949;i:1763677459;d:0.7638;i:1763677198;d:0.8293;i:1763676887;d:0.7515;i:1763676598;d:0.7432;i:1763676299;d:0.7589;i:1763675954;d:0.7635;i:1763675674;d:0.7297;i:1763675360;d:0.7934;i:1763675072;d:0.7921;i:1763674744;d:0.7122;i:1763674477;d:0.7657;i:1763674197;d:0.7378;i:1763673878;d:0.7524;i:1763673606;d:0.7932;i:1763673285;d:0.7358;i:1763672980;d:0.7872;i:1763672668;d:0.6946;i:1763672405;d:0.8329;i:1763672069;d:0.762;i:1763671784;d:0.7351;i:1763671508;d:0.7445;i:1763671136;d:0.7824;i:1763670868;d:0.7026;i:1763670561;d:0.7619;i:1763670274;d:0.737;i:1763669964;d:1.7155;i:1763669680;d:0.881;i:1763669365;d:0.7088;i:1763669111;d:0.7644;i:1763668770;d:0.7114;i:1763668462;d:0.7183;i:1763668155;d:0.7648;i:1763667864;d:0.782;i:1763667570;d:0.7333;i:1763667254;d:0.7441;i:1763666963;d:0.7905;i:1763666651;d:0.9803;i:1763666399;d:0.904;i:1763666074;d:0.7317;i:1763665751;d:0.8808;i:1763665466;d:1.3955;i:1763665128;d:0.7186;i:1763664830;d:0.7553;i:1763664546;d:0.758;i:1763664240;d:0.7617;i:1763663916;d:0.7272;i:1763663633;d:0.7469;i:1763663324;d:0.7978;i:1763663049;d:0.7985;i:1763662765;d:0.7015;i:1763662482;d:0.7329;i:1763662177;d:0.7505;i:1763661851;d:0.7752;i:1763661561;d:0.7466;i:1763661286;d:0.7259;i:1763660967;d:0.6728;i:1763660672;d:0.7968;i:1763660361;d:0.7197;i:1763660074;d:0.699;i:1763659771;d:0.7032;i:1763659504;d:0.7671;i:1763659254;d:0.7718;i:1763658871;d:0.7465;i:1763658572;d:0.7325;i:1763658318;d:0.7924;i:1763657996;d:0.6611;i:1763657668;d:0.7592;i:1763657364;d:0.7546;i:1763657097;d:0.7553;i:1763656814;d:0.7889;i:1763656501;d:0.7751;i:1763656214;d:0.7558;i:1763655932;d:0.7922;i:1763655640;d:0.7502;i:1763655382;d:0.7013;i:1763655068;d:0.7524;i:1763654801;d:0.7377;i:1763654546;d:0.7493;}s:17:"discovery_history";a:100:{i:1763740288;d:3.4821;i:1763724821;d:2.3726;i:1763703212;d:2.0967;i:1763681614;d:2.0858;i:1763660034;d:2.0252;i:1763650458;d:2.5142;i:1763616813;d:272.7564;i:1763595227;d:2.0346;i:1763573617;d:2.2476;i:1763552022;d:2.2766;i:1763530417;d:2.149;i:1763508814;d:2.1682;i:1763487225;d:2.199;i:1763465610;d:2.3714;i:1763444021;d:2.0346;i:1763422417;d:2.2388;i:1763400812;d:2.1825;i:1763379215;d:2.3203;i:1763357609;d:2.1019;i:1763336013;d:2.1189;i:1763314420;d:2.2217;i:1763292820;d:2.1847;i:1763271218;d:2.4175;i:1763249617;d:2.0702;i:1763228023;d:2.0506;i:1763206419;d:2.1485;i:1763184812;d:2.0045;i:1763163214;d:2.1;i:1763141609;d:2.1234;i:1763120015;d:2.211;i:1763098419;d:2.1049;i:1763076824;d:2.0609;i:1763055217;d:2.2514;i:1763033619;d:2.343;i:1763012013;d:2.1525;i:1762990414;d:2.005;i:1762968819;d:2.2185;i:1762947221;d:2.3136;i:1762925615;d:2.2303;i:1762904016;d:2.0773;i:1762882417;d:2.1797;i:1762860824;d:2.2632;i:1762839220;d:2.1899;i:1762817620;d:2.1764;i:1762796024;d:2.1657;i:1762774413;d:2.2797;i:1762752812;d:2.1543;i:1762731204;d:2.22;i:1762709612;d:2.2158;i:1762688005;d:2.2331;i:1762666415;d:2.1907;i:1762644809;d:2.1726;i:1762623222;d:2.2039;i:1762601612;d:2.2755;i:1762580010;d:2.2731;i:1762558417;d:2.1542;i:1762536811;d:2.1378;i:1762515209;d:2.284;i:1762493611;d:2.1136;i:1762472007;d:2.1643;i:1762450417;d:2.2058;i:1762428812;d:2.3586;i:1762407211;d:2.2056;i:1762385614;d:2.2162;i:1762364004;d:2.203;i:1762342415;d:2.17;i:1762320815;d:2.4106;i:1762299226;d:2.3167;i:1762277613;d:2.2806;i:1762256016;d:2.3245;i:1762234440;d:2.5276;i:1762212817;d:2.2586;i:1762191212;d:2.3033;i:1762169612;d:2.2558;i:1762148021;d:2.1495;i:1762126411;d:2.2184;i:1762104809;d:2.2295;i:1762083209;d:2.2314;i:1762061611;d:2.201;i:1762040011;d:2.2032;i:1762018418;d:2.1459;i:1761996816;d:2.147;i:1761975205;d:2.1418;i:1761953614;d:2.1471;i:1761932004;d:2.167;i:1761910417;d:2.2038;i:1761888807;d:2.1839;i:1761867216;d:2.1983;i:1761845612;d:2.2889;i:1761824008;d:2.1429;i:1761802412;d:2.1595;i:1761780810;d:2.1605;i:1761759218;d:2.208;i:1761737621;d:2.197;i:1761716013;d:2.1389;i:1761694410;d:2.3913;i:1761672809;d:2.2436;i:1761651218;d:2.2622;i:1761629617;d:2.0855;i:1761608017;d:2.0534;}s:18:"discovery_mod_perf";a:15:{s:2:"os";d:0.0885;s:4:"mibs";d:0.119;s:5:"ports";d:0.1286;s:4:"oids";d:0.1376;s:12:"ip-addresses";d:0.1252;s:10:"processors";d:0.0539;s:8:"mempools";d:0.0403;s:9:"inventory";d:0.1474;s:7:"sensors";d:2.1939;s:7:"storage";d:0.0616;s:10:"neighbours";d:0.0988;s:9:"arp-table";d:0.1058;s:14:"mac-accounting";d:0.0002;s:10:"ucd-diskio";d:0.0317;s:6:"graphs";d:0.0003;}} ) SQL[UPDATE `devices` set `uptime` ='14518579',`last_polled` =NOW(),`last_polled_timetaken` ='1.2179',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:18:{s:6:\"system\";d:0.1762;s:2:\"os\";d:0.0634;s:7:\"sensors\";d:0.3194;s:6:\"status\";d:0.0567;s:7:\"counter\";d:0.0037;s:10:\"processors\";d:0.0079;s:8:\"mempools\";d:0.0042;s:7:\"storage\";d:0.0152;s:13:\"ipSystemStats\";d:0.0466;s:5:\"ports\";d:0.2423;s:15:\"printersupplies\";d:0.0038;s:10:\"ucd-diskio\";d:0.0035;s:12:\"loadbalancer\";d:0.0002;s:15:\"entity-physical\";d:0.0001;s:9:\"fdb-table\";d:0.0719;s:6:\"graphs\";d:0.0849;s:4:\"oids\";d:0.0116;s:6:\"probes\";d:0.005;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.08016419410705566;s:13:\"EtherLike-MIB\";d:0.00010895729064941406;s:12:\"Q-BRIDGE-MIB\";d:0.14347386360168457;s:6:\"IP-MIB\";d:0.00020503997802734375;}s:14:\"poller_history\";a:288:{i:1763740310;d:1.2179;i:1763740214;d:0.7751;i:1763739910;d:0.7475;i:1763739581;d:0.7513;i:1763739312;d:0.7649;i:1763739026;d:0.7465;i:1763738740;d:0.7297;i:1763738497;d:0.7223;i:1763738155;d:0.7403;i:1763737783;d:0.7302;i:1763737514;d:0.7323;i:1763737201;d:0.8738;i:1763736893;d:0.778;i:1763736605;d:0.7297;i:1763736291;d:0.7021;i:1763736013;d:0.7834;i:1763735712;d:0.7541;i:1763735415;d:0.7911;i:1763735132;d:0.8034;i:1763734862;d:0.807;i:1763734529;d:0.7104;i:1763734249;d:0.707;i:1763733947;d:0.6838;i:1763733649;d:0.7483;i:1763733325;d:0.764;i:1763733035;d:0.8226;i:1763732711;d:0.7278;i:1763732415;d:0.7765;i:1763732108;d:0.7274;i:1763731789;d:0.735;i:1763731509;d:0.788;i:1763731234;d:0.753;i:1763730911;d:0.7166;i:1763730648;d:0.7399;i:1763730320;d:0.7845;i:1763730019;d:0.757;i:1763729731;d:0.7896;i:1763729419;d:0.7818;i:1763729130;d:0.8183;i:1763728821;d:0.8436;i:1763728527;d:0.7482;i:1763728212;d:0.7507;i:1763727948;d:0.7419;i:1763727673;d:0.7309;i:1763727361;d:0.7031;i:1763727050;d:0.7983;i:1763726739;d:0.7606;i:1763726426;d:0.7904;i:1763726039;d:0.7285;i:1763725854;d:0.7083;i:1763725551;d:0.7406;i:1763725276;d:0.7662;i:1763724946;d:0.7622;i:1763724670;d:5.753;i:1763724351;d:0.6997;i:1763724074;d:0.7733;i:1763723756;d:0.7261;i:1763723446;d:0.7323;i:1763723138;d:0.7693;i:1763722797;d:0.7134;i:1763722496;d:0.7603;i:1763722203;d:0.7889;i:1763721917;d:0.7394;i:1763721626;d:0.772;i:1763721321;d:0.7445;i:1763721024;d:0.7656;i:1763720749;d:0.7123;i:1763720493;d:0.7416;i:1763720188;d:0.7653;i:1763719917;d:0.7505;i:1763719582;d:0.712;i:1763719254;d:0.7752;i:1763718980;d:0.7677;i:1763718686;d:0.7732;i:1763718432;d:0.7741;i:1763718205;d:0.7073;i:1763718051;d:0.7221;i:1763717758;d:0.7664;i:1763717244;d:0.7196;i:1763717032;d:0.7559;i:1763716731;d:0.7991;i:1763716257;d:0.7177;i:1763715955;d:0.6848;i:1763715611;d:0.7924;i:1763715317;d:0.737;i:1763715008;d:0.7115;i:1763714680;d:0.7378;i:1763714444;d:0.7448;i:1763714134;d:0.7181;i:1763713814;d:0.7976;i:1763713518;d:0.6957;i:1763713204;d:0.7721;i:1763712940;d:0.7571;i:1763712568;d:0.6918;i:1763712277;d:0.7583;i:1763711966;d:0.722;i:1763711689;d:0.7773;i:1763711343;d:0.764;i:1763711061;d:0.7537;i:1763710766;d:0.764;i:1763710451;d:0.7419;i:1763710135;d:0.7357;i:1763709834;d:0.7265;i:1763709566;d:0.7121;i:1763709277;d:0.7046;i:1763708969;d:0.7558;i:1763708669;d:0.6979;i:1763708319;d:0.7719;i:1763708023;d:0.7667;i:1763707740;d:0.7434;i:1763707475;d:0.7567;i:1763707146;d:1.7324;i:1763706843;d:0.7553;i:1763706549;d:0.7153;i:1763706261;d:0.708;i:1763705983;d:0.7436;i:1763705664;d:0.7382;i:1763705368;d:0.781;i:1763705076;d:0.7771;i:1763704755;d:0.7577;i:1763704450;d:0.742;i:1763704152;d:0.7385;i:1763703851;d:0.7543;i:1763703531;d:0.7108;i:1763703232;d:0.7178;i:1763702943;d:0.6938;i:1763702647;d:0.7857;i:1763702375;d:0.7523;i:1763702066;d:0.7339;i:1763701768;d:0.7341;i:1763701430;d:0.6838;i:1763701156;d:0.7099;i:1763700831;d:0.7377;i:1763700580;d:0.7072;i:1763700249;d:0.764;i:1763699962;d:0.7221;i:1763699632;d:0.7239;i:1763699302;d:0.7187;i:1763699054;d:0.7202;i:1763698769;d:0.7437;i:1763698482;d:0.77;i:1763698166;d:1.7296;i:1763697840;d:0.7238;i:1763697543;d:0.7615;i:1763697233;d:0.7594;i:1763696942;d:0.7113;i:1763696642;d:0.7198;i:1763696355;d:0.7086;i:1763696045;d:0.7279;i:1763695731;d:0.692;i:1763695444;d:0.7799;i:1763695184;d:0.7339;i:1763694911;d:0.7734;i:1763694563;d:0.7293;i:1763694265;d:0.7396;i:1763693979;d:0.6871;i:1763693646;d:0.7094;i:1763693374;d:0.7309;i:1763693075;d:0.691;i:1763692763;d:0.7887;i:1763692447;d:0.7506;i:1763692151;d:0.7675;i:1763691857;d:0.7611;i:1763691563;d:0.7446;i:1763691292;d:0.7254;i:1763690982;d:0.796;i:1763690672;d:0.738;i:1763690347;d:0.7567;i:1763690047;d:0.7374;i:1763689744;d:0.7688;i:1763689433;d:0.7762;i:1763689168;d:0.7393;i:1763688841;d:0.7447;i:1763688617;d:0.7714;i:1763688271;d:0.7158;i:1763688003;d:0.7699;i:1763687685;d:0.7365;i:1763687359;d:0.704;i:1763687049;d:0.7574;i:1763686746;d:0.7695;i:1763686465;d:0.7411;i:1763686150;d:0.765;i:1763685831;d:0.6993;i:1763685536;d:0.7802;i:1763685230;d:0.7401;i:1763684954;d:0.7637;i:1763684661;d:0.7874;i:1763684361;d:0.7279;i:1763684063;d:0.7121;i:1763683749;d:0.7523;i:1763683480;d:0.7751;i:1763683184;d:0.7468;i:1763682852;d:0.7381;i:1763682576;d:0.7115;i:1763682260;d:0.7423;i:1763681947;d:0.7327;i:1763681651;d:0.8099;i:1763681353;d:0.7447;i:1763681074;d:0.732;i:1763680776;d:0.7382;i:1763680506;d:0.7632;i:1763680174;d:0.7297;i:1763679878;d:0.7171;i:1763679565;d:0.8012;i:1763679264;d:0.7054;i:1763678969;d:0.7358;i:1763678674;d:0.7342;i:1763678349;d:0.7563;i:1763678063;d:0.7981;i:1763677756;d:0.7949;i:1763677459;d:0.7638;i:1763677198;d:0.8293;i:1763676887;d:0.7515;i:1763676598;d:0.7432;i:1763676299;d:0.7589;i:1763675954;d:0.7635;i:1763675674;d:0.7297;i:1763675360;d:0.7934;i:1763675072;d:0.7921;i:1763674744;d:0.7122;i:1763674477;d:0.7657;i:1763674197;d:0.7378;i:1763673878;d:0.7524;i:1763673606;d:0.7932;i:1763673285;d:0.7358;i:1763672980;d:0.7872;i:1763672668;d:0.6946;i:1763672405;d:0.8329;i:1763672069;d:0.762;i:1763671784;d:0.7351;i:1763671508;d:0.7445;i:1763671136;d:0.7824;i:1763670868;d:0.7026;i:1763670561;d:0.7619;i:1763670274;d:0.737;i:1763669964;d:1.7155;i:1763669680;d:0.881;i:1763669365;d:0.7088;i:1763669111;d:0.7644;i:1763668770;d:0.7114;i:1763668462;d:0.7183;i:1763668155;d:0.7648;i:1763667864;d:0.782;i:1763667570;d:0.7333;i:1763667254;d:0.7441;i:1763666963;d:0.7905;i:1763666651;d:0.9803;i:1763666399;d:0.904;i:1763666074;d:0.7317;i:1763665751;d:0.8808;i:1763665466;d:1.3955;i:1763665128;d:0.7186;i:1763664830;d:0.7553;i:1763664546;d:0.758;i:1763664240;d:0.7617;i:1763663916;d:0.7272;i:1763663633;d:0.7469;i:1763663324;d:0.7978;i:1763663049;d:0.7985;i:1763662765;d:0.7015;i:1763662482;d:0.7329;i:1763662177;d:0.7505;i:1763661851;d:0.7752;i:1763661561;d:0.7466;i:1763661286;d:0.7259;i:1763660967;d:0.6728;i:1763660672;d:0.7968;i:1763660361;d:0.7197;i:1763660074;d:0.699;i:1763659771;d:0.7032;i:1763659504;d:0.7671;i:1763659254;d:0.7718;i:1763658871;d:0.7465;i:1763658572;d:0.7325;i:1763658318;d:0.7924;i:1763657996;d:0.6611;i:1763657668;d:0.7592;i:1763657364;d:0.7546;i:1763657097;d:0.7553;i:1763656814;d:0.7889;i:1763656501;d:0.7751;i:1763656214;d:0.7558;i:1763655932;d:0.7922;i:1763655640;d:0.7502;i:1763655382;d:0.7013;i:1763655068;d:0.7524;i:1763654801;d:0.7377;i:1763654546;d:0.7493;}s:17:\"discovery_history\";a:100:{i:1763740288;d:3.4821;i:1763724821;d:2.3726;i:1763703212;d:2.0967;i:1763681614;d:2.0858;i:1763660034;d:2.0252;i:1763650458;d:2.5142;i:1763616813;d:272.7564;i:1763595227;d:2.0346;i:1763573617;d:2.2476;i:1763552022;d:2.2766;i:1763530417;d:2.149;i:1763508814;d:2.1682;i:1763487225;d:2.199;i:1763465610;d:2.3714;i:1763444021;d:2.0346;i:1763422417;d:2.2388;i:1763400812;d:2.1825;i:1763379215;d:2.3203;i:1763357609;d:2.1019;i:1763336013;d:2.1189;i:1763314420;d:2.2217;i:1763292820;d:2.1847;i:1763271218;d:2.4175;i:1763249617;d:2.0702;i:1763228023;d:2.0506;i:1763206419;d:2.1485;i:1763184812;d:2.0045;i:1763163214;d:2.1;i:1763141609;d:2.1234;i:1763120015;d:2.211;i:1763098419;d:2.1049;i:1763076824;d:2.0609;i:1763055217;d:2.2514;i:1763033619;d:2.343;i:1763012013;d:2.1525;i:1762990414;d:2.005;i:1762968819;d:2.2185;i:1762947221;d:2.3136;i:1762925615;d:2.2303;i:1762904016;d:2.0773;i:1762882417;d:2.1797;i:1762860824;d:2.2632;i:1762839220;d:2.1899;i:1762817620;d:2.1764;i:1762796024;d:2.1657;i:1762774413;d:2.2797;i:1762752812;d:2.1543;i:1762731204;d:2.22;i:1762709612;d:2.2158;i:1762688005;d:2.2331;i:1762666415;d:2.1907;i:1762644809;d:2.1726;i:1762623222;d:2.2039;i:1762601612;d:2.2755;i:1762580010;d:2.2731;i:1762558417;d:2.1542;i:1762536811;d:2.1378;i:1762515209;d:2.284;i:1762493611;d:2.1136;i:1762472007;d:2.1643;i:1762450417;d:2.2058;i:1762428812;d:2.3586;i:1762407211;d:2.2056;i:1762385614;d:2.2162;i:1762364004;d:2.203;i:1762342415;d:2.17;i:1762320815;d:2.4106;i:1762299226;d:2.3167;i:1762277613;d:2.2806;i:1762256016;d:2.3245;i:1762234440;d:2.5276;i:1762212817;d:2.2586;i:1762191212;d:2.3033;i:1762169612;d:2.2558;i:1762148021;d:2.1495;i:1762126411;d:2.2184;i:1762104809;d:2.2295;i:1762083209;d:2.2314;i:1762061611;d:2.201;i:1762040011;d:2.2032;i:1762018418;d:2.1459;i:1761996816;d:2.147;i:1761975205;d:2.1418;i:1761953614;d:2.1471;i:1761932004;d:2.167;i:1761910417;d:2.2038;i:1761888807;d:2.1839;i:1761867216;d:2.1983;i:1761845612;d:2.2889;i:1761824008;d:2.1429;i:1761802412;d:2.1595;i:1761780810;d:2.1605;i:1761759218;d:2.208;i:1761737621;d:2.197;i:1761716013;d:2.1389;i:1761694410;d:2.3913;i:1761672809;d:2.2436;i:1761651218;d:2.2622;i:1761629617;d:2.0855;i:1761608017;d:2.0534;}s:18:\"discovery_mod_perf\";a:15:{s:2:\"os\";d:0.0885;s:4:\"mibs\";d:0.119;s:5:\"ports\";d:0.1286;s:4:\"oids\";d:0.1376;s:12:\"ip-addresses\";d:0.1252;s:10:\"processors\";d:0.0539;s:8:\"mempools\";d:0.0403;s:9:\"inventory\";d:0.1474;s:7:\"sensors\";d:2.1939;s:7:\"storage\";d:0.0616;s:10:\"neighbours\";d:0.0988;s:9:\"arp-table\";d:0.1058;s:14:\"mac-accounting\";d:0.0002;s:10:\"ucd-diskio\";d:0.0317;s:6:\"graphs\";d:0.0003;}}' WHERE `device_id` = '855'] SQL RUNTIME[0.00290298s]  o Updated Data  uptime, last_polled, last_polled_timetaken, device_state Checking alert 19 associated by Testing: device_rebooted is 1 (value: 0) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-19-device-855.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-19-device-855.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.22] RRD_STATUS[TRUE]  Checking alert 25 associated by Testing: device_status eq 0 (value: 1) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/alert-25-device-855.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/alert-25-device-855.rrd N:1:1 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.23] RRD_STATUS[TRUE]   SQL[INSERT INTO `alert_table` (`alert_table_id`,`count`,`state`,`alert_status`,`last_message`,`last_changed`,`last_checked`,`last_ok`,`last_failed`,`last_alerted`) VALUES ('3069431','0','{\"metrics\":{\"sensor_value\":100}}','1','Checks OK','1763650564','1763740310','1763740310',NULL,'0'),('3069433','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650564','1763740310','1763740310',NULL,'0'),('3069432','0','{\"metrics\":{\"sensor_value\":17}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069434','0','{\"metrics\":{\"sensor_value\":49.900000000000006}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069441','0','{\"metrics\":{\"sensor_value\":50.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069468','0','{\"metrics\":{\"sensor_value\":50.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069435','0','{\"metrics\":{\"sensor_value\":232.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069436','0','{\"metrics\":{\"sensor_value\":232.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069437','0','{\"metrics\":{\"sensor_value\":232.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069442','0','{\"metrics\":{\"sensor_value\":231.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069443','0','{\"metrics\":{\"sensor_value\":230.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069444','0','{\"metrics\":{\"sensor_value\":230.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069451','0','{\"metrics\":{\"sensor_value\":232.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069452','0','{\"metrics\":{\"sensor_value\":231.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069453','0','{\"metrics\":{\"sensor_value\":231.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069458','0','{\"metrics\":{\"sensor_value\":567.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069438','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069439','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069440','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069445','0','{\"metrics\":{\"sensor_value\":70.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069446','0','{\"metrics\":{\"sensor_value\":64.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069447','0','{\"metrics\":{\"sensor_value\":48.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069454','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069455','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069456','0','{\"metrics\":{\"sensor_value\":0.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069448','0','{\"metrics\":{\"sensor_value\":19}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069449','0','{\"metrics\":{\"sensor_value\":17}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069450','0','{\"metrics\":{\"sensor_value\":13}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069467','0','{\"metrics\":{\"sensor_value\":19}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069457','0','{\"metrics\":{\"sensor_value\":23.0}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069470','0','{\"metrics\":{\"sensor_event\":\"ok\"}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069459','0','{\"metrics\":{\"sensor_value\":16000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069460','0','{\"metrics\":{\"sensor_value\":14000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069461','0','{\"metrics\":{\"sensor_value\":11000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069465','0','{\"metrics\":{\"sensor_value\":41000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069462','0','{\"metrics\":{\"sensor_value\":15000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069463','0','{\"metrics\":{\"sensor_value\":14000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069464','0','{\"metrics\":{\"sensor_value\":10000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069466','0','{\"metrics\":{\"sensor_value\":39000}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069420','0','{\"metrics\":{\"status_event\":\"ok\"}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('3069421','0','{\"metrics\":{\"status_event\":\"ok\"}}','1','Checks OK','1763650565','1763740310','1763740310',NULL,'0'),('860933','0','{\"metrics\":{\"device_rebooted\":0}}','1','Checks OK','1754408469','1763740311','1763740311',NULL,'0'),('860934','0','{\"metrics\":{\"device_status\":\"1\"}}','1','Checks OK','1763617542','1763740311','1763740311','1763617471','1763617472') ON DUPLICATE KEY UPDATE `alert_table_id`=VALUES(`alert_table_id`),`count`=VALUES(`count`),`state`=VALUES(`state`),`alert_status`=VALUES(`alert_status`),`last_message`=VALUES(`last_message`),`last_changed`=VALUES(`last_changed`),`last_checked`=VALUES(`last_checked`),`last_ok`=VALUES(`last_ok`),`last_failed`=VALUES(`last_failed`),`last_alerted`=VALUES(`last_alerted`)] SQL RUNTIME[0.00253701s]  SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '3678779' AND `process_name` = 'poller.php' AND `device_id` = '855' AND `poller_id` = '0'] SQL RUNTIME[0.00109506s] poller.php: ups24-datacenter.cri.ulm - 1 devices polled in 1.4342 secs ##### Completed polling run at 2025-11-21 15:51:51 #####  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollerdb.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollerdb.rrd N:1:0.00554919:15:0.11100577:2:0.00834418:10:0.053370714187622:7:0.03519487:13:0.11036396026611:31:0.18515539169312:82:0.52195929205872 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.24] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollermemory.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollermemory.rrd N:27262976:27262976 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.24] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollersnmp.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollersnmp.rrd N:17:0.34094309806824:7:0.20203995704651:U:U:24:0.54298305511475 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.24] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/ups24-datacenter.cri.ulm/perf-pollersnmp_errors.rrd already exists - no need to create. RRD CMD[update ups24-datacenter.cri.ulm/perf-pollersnmp_errors.rrd N:4:0.079773902893066:7:0.20203995704651:11:0.28181385993958 --daemon unix:/var/run/rrdcached.sock] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.02 s:0.01 r:1.24] RRD_STATUS[TRUE]  NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Polled  1  o Poller Time  1.4342 secs  o Definitions  0.19041800498962 secs  o Memory usage  26MB (peak: 26MB)  o MySQL Usage  Insert[1/0.006s] Update[15/0.111s] Delete[2/0.008s] Cell[10/0.053s] Row[13/0.11s] Rows[31/0.185s] Col[7/0.035s] Connect[1/0.002s]Func[2/0.011s] (0.522s 36.394%)   o RRDTool Usage  update[110/0.12s] (0.12s 8.396%)  o SNMP Usage  snmpget[17/0.341s] errors[/0s] snmpwalk[7/0.202s] (0.543s 37.86%)