------------------------------------------------------------ -- EMERSON NETWORK POWER -- RDU-SIC G2 Device MIB. -- Using Generate Template V1.0 -- Copyright 2008-2015 Emerson Corporation. -- All rights reserved. ------------------------------------------------------------ ENP_AC_CRV+-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,Integer32, Counter32, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString, DateAndTime FROM SNMPv2-TC; ------------------------------------------------------------ -- Node definitions ------------------------------------------------------------ enp OBJECT IDENTIFIER ::= { enterprises 13400 } products OBJECT IDENTIFIER ::= { enp 2 } ENP_AC_CRV+ MODULE-IDENTITY LAST-UPDATED "201309020955Z" ORGANIZATION "EMERSON NETWORK POWER (ENPC)" CONTACT-INFO "EMERSON NETWORK POWER" REVISION "200" DESCRIPTION "EMERSON NETWORK POWER (ENPC) For RDU-SIC G2 MIB." ::= { products 339 } ------------------------------------------------------------ -- Textual conventions ------------------------------------------------------------ AlarmSeverity ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " The severity of the alarm. One of (1) informational (2) warning (3) critical" SYNTAX INTEGER { informational(1), warning(2), critical(3) } AlarmStatusChange ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Indicates 'activated' (0) or 'deactivated' (1) alarm events." SYNTAX INTEGER { activated(0), deactivated(1) } ------------------------------------------------------------ -- 1.1 Identification of the device { ENP_AC_CRV+ 1 } ------------------------------------------------------------ ident OBJECT IDENTIFIER ::= { ENP_AC_CRV+ 1 } identManufacturer OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The name of the device manufacturer." ::= { ident 1 } identModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The manufacturers model designation of the device." ::= { ident 2 } identIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The sequence number of the device." ::= { ident 3 } ------------------------------------------------------------ -- 1.2 system values { ENP_AC_CRV+ 2 } ------------------------------------------------------------ system OBJECT IDENTIFIER ::= { ENP_AC_CRV+ 2 } ------------------------------------------------------------ --gourp2 ------------------------------------------------------------ group2 OBJECT IDENTIFIER ::= { system 2 } softshutdownstatus OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "softshutdownstatus, status." ::= { group2 2} paneloff OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "paneloff, status." ::= { group2 3} monitorshutdown OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "monitorshutdown, status." ::= { group2 4} refrigeration OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "refrigeration, status." ::= { group2 5} heatingflag OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "heatingflag, status." ::= { group2 6} humidification OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "humidification, status." ::= { group2 7} dehumidifying OBJECT-TYPE SYNTAX INTEGER { no(0), yes(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "dehumidifying, status." ::= { group2 8} fan1status OBJECT-TYPE SYNTAX INTEGER { normal(0), fault(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fan1status, status." ::= { group2 9} fan2status OBJECT-TYPE SYNTAX INTEGER { normal(0), fault(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fan2status, status." ::= { group2 10} fan3status OBJECT-TYPE SYNTAX INTEGER { normal(0), fault(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fan3status, status." ::= { group2 11} fan4status OBJECT-TYPE SYNTAX INTEGER { normal(0), fault(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fan4status, status." ::= { group2 12} condensatepumpoutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "condensatepumpoutput, status." ::= { group2 13} compressoroutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressoroutput, status." ::= { group2 14} electricheatingoutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "electricheatingoutput, status." ::= { group2 15} fanoutput OBJECT-TYPE SYNTAX INTEGER { outputenable(0), outputclose(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fanoutput, status." ::= { group2 16} humidifieroutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "humidifieroutput, status." ::= { group2 17} commonalarmoutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "commonalarmoutput, status." ::= { group2 18} liquidsolenoidvalveoutput OBJECT-TYPE SYNTAX INTEGER { outputclose(0), outputenable(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "liquidsolenoidvalveoutput, status." ::= { group2 19} highpressurealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "highpressurealarm, status." ::= { group2 20} lowpressurealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lowpressurealarm, status." ::= { group2 21} abnormalhighpressurealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "abnormalhighpressurealarm, status." ::= { group2 22} exhausttemperaturealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "exhausttemperaturealarm, status." ::= { group2 23} exhaustlowsuperheat OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "exhaustlowsuperheat, status." ::= { group2 24} returnairhightempalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "returnairhightempalarm, status." ::= { group2 25} supplyairlowtempalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "supplyairlowtempalarm, status." ::= { group2 26} supplyairhightempalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "supplyairhightempalarm, status." ::= { group2 27} returnairhighhumalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "returnairhighhumalarm, status." ::= { group2 28} returnairlowhumalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "returnairlowhumalarm, status." ::= { group2 29} highpressurelockalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "highpressurelockalarm, status." ::= { group2 30} lowpressurelockalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lowpressurelockalarm, status." ::= { group2 31} lockexhausttemperaturealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lockexhausttemperaturealarm, status." ::= { group2 32} lowexhaustsuperheatlockalar OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lowexhaustsuperheatlockalar, status." ::= { group2 33} powerlossalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "powerlossalarm, status." ::= { group2 34} powerovervoltagealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "powerovervoltagealarm, status." ::= { group2 35} powerundervoltagealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "powerundervoltagealarm, status." ::= { group2 36} powerlosephasealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "powerlosephasealarm, status." ::= { group2 37} flooroverflowalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "flooroverflowalarm, status." ::= { group2 38} highwaterlevelalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "highwaterlevelalarm, status." ::= { group2 39} filtercloggedalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "filtercloggedalarm, status." ::= { group2 40} filtermaintenance OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "filtermaintenance, status." ::= { group2 41} airflowlossalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "airflowlossalarm, status." ::= { group2 42} lowpressuresensorlock OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lowpressuresensorlock, status." ::= { group2 43} remoteshutdownalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "remoteshutdownalarm, status." ::= { group2 44} grouphostlossalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "grouphostlossalarm, status." ::= { group2 45} groupslavelossalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "groupslavelossalarm, status." ::= { group2 46} returnairtempsensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "returnairtempsensorfault, status." ::= { group2 47} returnairhumsensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "returnairhumsensorfault, status." ::= { group2 48} supplyairtempdiffsensorfau OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "supplyairtempdiffsensorfau, status." ::= { group2 49} supplyairtempsensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "supplyairtempsensorfault, status." ::= { group2 50} remotetempsensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "remotetempsensorfault, status." ::= { group2 51} highpressuresensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "highpressuresensorfault, status." ::= { group2 52} electricheatingfailurealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "electricheatingfailurealarm, status." ::= { group2 53} exhaustgastempsensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "exhaustgastempsensorfault, status." ::= { group2 54} fanpowerfailure OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "fanpowerfailure, status." ::= { group2 55} eevcommunicationfailure OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "eevcommunicationfailure, status." ::= { group2 56} notselectedrefrigerantalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "notselectedrefrigerantalarm, status." ::= { group2 57} refrigerantshortagealarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "refrigerantshortagealarm, status." ::= { group2 58} intakeairtemperaturesensorf OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "intakeairtemperaturesensorf, status." ::= { group2 59} lowpressuresensorfault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "lowpressuresensorfault, status." ::= { group2 60} compressordrivecommunication OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressordrivecommunication, status." ::= { group2 61} compressordrivefault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressordrivefault, status." ::= { group2 62} compressorradiatorovertemper OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressorradiatorovertemper, status." ::= { group2 63} compressorovercurrentprotecti OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressorovercurrentprotecti, status." ::= { group2 64} compressorphaselossprotectio OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressorphaselossprotectio, status." ::= { group2 65} compressorbusvoltagefault OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "compressorbusvoltagefault, status." ::= { group2 66} humidifierfaultalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "humidifierfaultalarm, status." ::= { group2 67} groupaddressrepeatedalarm OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "groupaddressrepeatedalarm, status." ::= { group2 68} supplyairtemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "supplyairtemperature, stored as 0.01℃." ::= { group2 69} returnairtemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "returnairtemperature, stored as 0.01℃." ::= { group2 70} returnairhumidity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "returnairhumidity, stored as 0.01." ::= { group2 71} theoreticalairhumidity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "theoreticalairhumidity, stored as 0.01." ::= { group2 72} aphasevoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "aphasevoltage, stored as 0.01V." ::= { group2 73} bphasevoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "bphasevoltage, stored as 0.01V." ::= { group2 74} cphasevoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "cphasevoltage, stored as 0.01V." ::= { group2 75} powerfrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "powerfrequency, stored as 0.01Hz." ::= { group2 76} unitoperationstatus OBJECT-TYPE SYNTAX INTEGER { run(0), shutdown(1), standby(2), locking(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "unitoperationstatus, status." ::= { group2 77} unitgroupcontrolmode OBJECT-TYPE SYNTAX INTEGER { single(0), groupcontrol(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "unitgroupcontrolmode, status." ::= { group2 78} compressorcapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "compressorcapacity, stored as 0.01." ::= { group2 79} fanspeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "fanspeed, stored as 0.01." ::= { group2 80} communicatestatus OBJECT-TYPE SYNTAX INTEGER { normal(0), alarm(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "communicatestatus, status." ::= { group2 81} ------------------------------------------------------------ --gourp3 ------------------------------------------------------------ group3 OBJECT IDENTIFIER ::= { system 3 } remoteon OBJECT-TYPE SYNTAX INTEGER { run(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "remoteon, status." ::= { group3 82} remoteoff OBJECT-TYPE SYNTAX INTEGER { shutdown(0) } MAX-ACCESS read-write STATUS current DESCRIPTION "remoteoff, status." ::= { group3 83} ------------------------------------------------------------ --gourp4 ------------------------------------------------------------ group4 OBJECT IDENTIFIER ::= { system 4 } supplyairtemperaturesetpoint OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "supplyairtemperaturesetpoint, stored as 1℃." ::= { group4 84} remotetemperaturesetpoint OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "remotetemperaturesetpoint, stored as 1℃." ::= { group4 85} returnairtemperaturesetpoin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "returnairtemperaturesetpoin, stored as 1℃." ::= { group4 86} supplyairhumiditysetpoint OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "supplyairhumiditysetpoint, stored as 1." ::= { group4 87} lognumberset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "lognumberset, stored as 1." ::= { group4 88} ------------------------------------------------------------ -- 3 Alarm trap table -- If you want to know the equipment trap list detail, -- Please find a Excel file named "RDU-SIC G2 trap table"; ------------------------------------------------------------ alarmTrapTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Table holding information about the submitted alarm traps." ::= { ENP_AC_CRV+ 3 } alarmTrapEntry OBJECT-TYPE SYNTAX AlarmTrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " An entry (conceptual row) in the alarmTrapTable." INDEX { alarmIndex } ::= { alarmTrapTable 1 } AlarmTrapEntry ::= SEQUENCE { alarmIndex Counter32, alarmTime DisplayString, alarmStatusChange StatusChange, alarmSeverity Status, alarmDescription DisplayString, alarmId Integer32 } alarmIndex OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " The unique sequence number of this alarm trap." ::= { alarmTrapEntry 1 } alarmTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Date and time when event occured." ::= { alarmTrapEntry 2 } alarmStatusChange OBJECT-TYPE SYNTAX StatusChange MAX-ACCESS read-only STATUS current DESCRIPTION " Indicates 'activated' (0) or 'deactivated' (1) alarm events." ::= { alarmTrapEntry 3 } alarmSeverity OBJECT-TYPE SYNTAX Status MAX-ACCESS read-only STATUS current DESCRIPTION " The severity of the alarm. One of (0) informational (1) warning (2) critical" ::= { alarmTrapEntry 4 } alarmDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " Free-text description of alarm." ::= { alarmTrapEntry 5 } alarmId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm Index in system." ::= { alarmTrapEntry 6 } ------------------------------------------------------------ -- System Alarm Trap Define ------------------------------------------------------------ systemAlarmTrap OBJECT IDENTIFIER ::= { ENP_AC_CRV+ 4 } systemAlarmTrapFormatDefine NOTIFICATION-TYPE OBJECTS { systemAlarmIndex, systemAlarmTime, systemAlarmStatusChange, systemAlarmSeverity, systemAlarmDescription, systemAlarmId, systemAlarmEquipId, systemAlarmEquipTypeId } STATUS current DESCRIPTION " An alarm trap is sent when an alarm occurs (activated) or returns to normal state (deactivated). Alarm traps are logged in alarmTrapTable. Variables in this trap: * systemAlarmIndex - The unique sequence number of this alarm trap. * systemAlarmTime - Date and time when event occured (local time). * systemAlarmStatusChange - (0) activated or (1) deactivated. * systemAlarmSeverity - The severity of the alarm.. * systemAlarmId - Alarm id. * systemAlarmEquipId - Alarm equipment id. * systemAlarmEquipTypeId - Alarm equipment type id." ::= { systemAlarmTrap 1 } ------------------------------------------------------------ -- End of MIB definitions ------------------------------------------------------------ END