root@observium:/opt/observium# ./discovery.php -d -h gis01-idrac DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0194s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: https://svn.observium.org/svn/observium/branches/stable Relative URL: ^/observium/branches/stable Repository Root: https://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 13175 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 13173 Last Changed Date: 2023-11-14 20:15:39 +0100 (Tue, 14 Nov 2023) ] DEFINITIONS Time : 0.131577 ms DEFINITIONS Memory: 15.7MB SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.000705s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00040984s] SQL[SET SESSION `sql_mode` = 'NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00022697s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00026488s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00061393s] CMD[/bin/hostname -f] CMD EXITCODE[0] CMD RUNTIME[0.0073s] CMD EXITDELAY[5ms] STDOUT[ observium ] SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)] SQL RUNTIME[0.00061607s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 23.11.13173 https://www.observium.org CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.0453s] STDOUT[ Linux|5.15.0-88-generic|amd64|Ubuntu|22.04|xenpv| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.008s] STDOUT[ Python 3.10.12 ] SQL[SELECT version();] SQL RUNTIME[0.00059605s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0104s] STDOUT[ NET-SNMP version: 5.9.1 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0186s] STDOUT[ RRDtool 1.7.2 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0041s] STDOUT[ /usr/bin/fping: Version 5.1 ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0356s] STDOUT[ Apache/2.4.52 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00059891s] SQL[SHOW VARIABLES LIKE 'log_bin'] SQL RUNTIME[0.00530601s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00434208s] ##### Software versions ##### o OS Linux 5.15.0-88-generic [amd64] (Ubuntu 22.04) o Apache 2.4.52 o PHP 8.1.2-1ubuntu2.14 (OPcache: DISABLED) o Python 3.10.12 o MySQL 8.0.35-0ubuntu0.22.04.1 (extension: mysqli 8.1.2-1ubuntu2.14) o SNMP NET-SNMP 5.9.1 o RRDtool 1.7.2 o Fping 5.1 (IPv4 and IPv6) o Fetch cURL 7.81.0 (OpenSSL/3.0.2, LibZ 1.2.11, LibIDN 2.3.2) ##### Memory Limit ##### o PHP Unlimited ##### DB info ##### o DB schema 491 o MySQL binlog ON o MySQL mode NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MySQL utf8mb3 ##### Timezones info ##### o Date Thursday, 16-Nov-23 07:54:45 CET o PHP +01:00 o MySQL +01:00 ##### Starting discovery run at 2023-11-16 07:54:45 ##### SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'gis01-idrac' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00143409s] CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0] CMD EXITCODE[0] CMD RUNTIME[0.0252s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.674.10892.5 .1.3.6.1.2.1.1.3.0 = 22:16:50:42.46 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '5'] SQL RUNTIME[0.00088215s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '5' AND `poller_id` = '0'] SQL RUNTIME[0.00074816s] SQL[DELETE FROM `observium_processes` WHERE `process_id` = '910877'] SQL RUNTIME[0.00459719s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('1374532','discovery.php','1339003','0','php ./discovery.php -d -h gis01-idrac','1700117685','5')] SQL RUNTIME[0.00360298s] ##### gis01-idrac [5] ##### o OS Type drac o SNMP Version v2c o Last discovery 2023-11-16 06:51:09 o Last duration 13.21 seconds ##### Module Start: os ##### Device-specific no-bulk option. CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' sysDescr.0] CMD EXITCODE[0] CMD RUNTIME[0.0213s] STDOUT[ ] SNMP STATUS[FALSE] SNMP ERROR[#1 - Empty response] Store in cache OID: SNMPv2-MIB::sysDescr.0 Device-specific no-bulk option. CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' sysObjectID.0] CMD EXITCODE[0] CMD RUNTIME[0.0292s] STDOUT[ .1.3.6.1.4.1.674.10892.5 ] SNMP STATUS[TRUE] +-------------+--------------------------+ | OID | | +-------------+--------------------------+ | sysDescr | | | sysObjectID | .1.3.6.1.4.1.674.10892.5 | +-------------+--------------------------+ o Detect OS matched (drac: Dell iDRAC): +-------------+-------------------------+--------------------------+ | OID | Matched definition | | +-------------+-------------------------+--------------------------+ | sysObjectID | .1.3.6.1.4.1.674.10892. | .1.3.6.1.4.1.674.10892.5 | +-------------+-------------------------+--------------------------+ o Duration 0.0975s ##### Module Start: mibs ##### CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID'] CMD EXITCODE[0] CMD RUNTIME[0.0248s] STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' .1.3.6.1.2.1.1.9.1.2] CMD EXITCODE[0] CMD RUNTIME[0.027s] STDOUT[ .1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1 .1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.16.2.2.1 .1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.2.1.49 .1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.2.1.50 .1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.2.1.4 .1.3.6.1.2.1.1.9.1.2.6 = .1.3.6.1.6.3.10.3.1.1 .1.3.6.1.2.1.1.9.1.2.7 = .1.3.6.1.6.3.11.3.1.1 .1.3.6.1.2.1.1.9.1.2.8 = .1.3.6.1.6.3.15.2.1.1 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' sysORDescr] CMD EXITCODE[0] CMD RUNTIME[0.0186s] STDOUT[ sysORDescr.1 = The MIB module for SNMPv2 entities sysORDescr.2 = View-based Access Control Model for SNMP. sysORDescr.3 = The MIB module for managing TCP implementations sysORDescr.4 = The MIB module for managing UDP implementations sysORDescr.5 = The MIB module for managing IP and ICMP implementations sysORDescr.6 = The SNMP Management Architecture MIB. sysORDescr.7 = The MIB for Message Processing and Dispatching. sysORDescr.8 = The management information definitions for the SNMP User-based Security Model. ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ospfAdminStat.0] CMD EXITCODE[0] CMD RUNTIME[0.0303s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: OSPF-MIB::ospfAdminStat.0 CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m OSPFV3-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ospfv3AdminStatus.0] CMD EXITCODE[0] CMD RUNTIME[0.0318s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: OSPFV3-MIB::ospfv3AdminStatus.0 CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m LLDP-V2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' lldpV2LocChassisId.0] CMD EXITCODE[0] CMD RUNTIME[0.0361s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: LLDP-V2-MIB::lldpV2LocChassisId.0 CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m LLDP-EXT-MED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' lldpXMedLocModelName.0] CMD EXITCODE[0] CMD RUNTIME[0.035s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: LLDP-EXT-MED-MIB::lldpXMedLocModelName.0 o MIBs discovered TCP-MIB UDP-MIB +-----------------------+--------------------+---------+---------------------+ | Identity | MIB | Source | Status | +-----------------------+--------------------+---------+---------------------+ | .1.3.6.1.6.3.1 | SNMPv2-MIB | sysORID | MIB already defined | | .1.3.6.1.2.1.4 | IP-MIB | sysORID | MIB already defined | | .1.3.6.1.2.1.49 | TCP-MIB | sysORID | MIB added | | .1.3.6.1.2.1.50 | UDP-MIB | sysORID | MIB added | | .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined | | .1.3.6.1.6.3.16.2.2.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.11.3.1.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.15.2.1.1 | - | sysORID | Unknown Identity | +-----------------------+--------------------+---------+---------------------+ SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '5' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00058699s] Array ( [0] => TCP-MIB [1] => UDP-MIB [2] => IDRAC-MIB-SMIv2 [3] => DELL-RAC-MIB [4] => SNMPv2-MIB [5] => SNMP-FRAMEWORK-MIB [6] => IF-MIB [7] => ADSL-LINE-MIB [8] => EtherLike-MIB [9] => ENTITY-MIB [10] => ENTITY-SENSOR-MIB [11] => UCD-SNMP-MIB [12] => HOST-RESOURCES-MIB [13] => Q-BRIDGE-MIB [14] => IP-MIB [15] => IPV6-MIB [16] => LLDP-MIB [17] => CISCO-CDP-MIB [18] => PW-STD-MIB [19] => DISMAN-PING-MIB [20] => BGP4-MIB ) o Duration 0.2462s ##### Module Start: vrf ##### SQL[SELECT COUNT(*) FROM `vrfs` WHERE `device_id` = '5' AND 1] SQL RUNTIME[0.00032997s] SQL[SELECT COUNT(*) FROM `ports` WHERE `device_id` = '5' AND `ifVrf` IS NOT NULL AND 1] SQL RUNTIME[0.00048184s] o Duration 0.0031s ##### Module Start: ports ##### o Caching OIDs ifDescr CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifDescr] CMD EXITCODE[0] CMD RUNTIME[0.0297s] STDOUT[ ifDescr.1 = lo ifDescr.2 = eth2 ifDescr.3 = eth3 ifDescr.4 = eth0 ifDescr.5 = tunl0 ifDescr.6 = sit0 ifDescr.7 = usb0 ifDescr.8 = usb1 ifDescr.9 = bond0 ifDescr.10 = usbpt ] SNMP STATUS[TRUE] ifAlias CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifAlias] CMD EXITCODE[0] CMD RUNTIME[0.0218s] STDOUT[ ifAlias.1 = ifAlias.2 = ifAlias.3 = ifAlias.4 = ifAlias.5 = ifAlias.6 = ifAlias.7 = ifAlias.8 = ifAlias.9 = ifAlias.10 = ] SNMP STATUS[TRUE] ifName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifName] CMD EXITCODE[0] CMD RUNTIME[0.0389s] STDOUT[ ifName.1 = lo ifName.2 = eth2 ifName.3 = eth3 ifName.4 = eth0 ifName.5 = tunl0 ifName.6 = sit0 ifName.7 = usb0 ifName.8 = usb1 ifName.9 = bond0 ifName.10 = usbpt ] SNMP STATUS[TRUE] ifType CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifType] CMD EXITCODE[0] CMD RUNTIME[0.0299s] STDOUT[ ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = tunnel ifType.6 = tunnel ifType.7 = ethernetCsmacd ifType.8 = ethernetCsmacd ifType.9 = ethernetCsmacd ifType.10 = ethernetCsmacd ] SNMP STATUS[TRUE] ifOperStatus CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifOperStatus] CMD EXITCODE[0] CMD RUNTIME[0.0319s] STDOUT[ ifOperStatus.1 = up ifOperStatus.2 = up ifOperStatus.3 = up ifOperStatus.4 = up ifOperStatus.5 = down ifOperStatus.6 = down ifOperStatus.7 = down ifOperStatus.8 = down ifOperStatus.9 = up ifOperStatus.10 = down ] SNMP STATUS[TRUE] Array ( [1] => Array ( [ifDescr] => lo [ifAlias] => [ifName] => lo [ifType] => softwareLoopback [ifOperStatus] => up ) [2] => Array ( [ifDescr] => eth2 [ifAlias] => [ifName] => eth2 [ifType] => ethernetCsmacd [ifOperStatus] => up ) [3] => Array ( [ifDescr] => eth3 [ifAlias] => [ifName] => eth3 [ifType] => ethernetCsmacd [ifOperStatus] => up ) [4] => Array ( [ifDescr] => eth0 [ifAlias] => [ifName] => eth0 [ifType] => ethernetCsmacd [ifOperStatus] => up ) [5] => Array ( [ifDescr] => tunl0 [ifAlias] => [ifName] => tunl0 [ifType] => tunnel [ifOperStatus] => down ) [6] => Array ( [ifDescr] => sit0 [ifAlias] => [ifName] => sit0 [ifType] => tunnel [ifOperStatus] => down ) [7] => Array ( [ifDescr] => usb0 [ifAlias] => [ifName] => usb0 [ifType] => ethernetCsmacd [ifOperStatus] => down ) [8] => Array ( [ifDescr] => usb1 [ifAlias] => [ifName] => usb1 [ifType] => ethernetCsmacd [ifOperStatus] => down ) [9] => Array ( [ifDescr] => bond0 [ifAlias] => [ifName] => bond0 [ifType] => ethernetCsmacd [ifOperStatus] => up ) [10] => Array ( [ifDescr] => usbpt [ifAlias] => [ifName] => usbpt [ifType] => ethernetCsmacd [ifOperStatus] => down ) ) o Caching DB SQL[SELECT * FROM `ports` WHERE `device_id` = '5'] SQL RUNTIME[0.00093603s] 10 ports o Discovering ports ifIndex 1 (ifAdminStatus = , ifOperStatus = up). . ifIndex 2 (ifAdminStatus = , ifOperStatus = up). . ifIndex 3 (ifAdminStatus = , ifOperStatus = up). . ifIndex 4 (ifAdminStatus = , ifOperStatus = up). . ifIndex 5 (ifAdminStatus = , ifOperStatus = down). . ifIndex 6 (ifAdminStatus = , ifOperStatus = down). . ifIndex 7 (ifAdminStatus = , ifOperStatus = down). . ifIndex 8 (ifAdminStatus = , ifOperStatus = down). . ifIndex 9 (ifAdminStatus = , ifOperStatus = up). . ifIndex 10 (ifAdminStatus = , ifOperStatus = down). . +---------+---------+--------+---------+------------------+-------------+---------+ | ifIndex | ifDescr | ifName | ifAlias | ifType | Oper Status | Ignored | +---------+---------+--------+---------+------------------+-------------+---------+ | 1 | lo | lo | ... | softwareLoopback | up | no | | 2 | eth2 | eth2 | ... | ethernetCsmacd | up | no | | 3 | eth3 | eth3 | ... | ethernetCsmacd | up | no | | 4 | eth0 | eth0 | ... | ethernetCsmacd | up | no | | 5 | tunl0 | tunl0 | ... | tunnel | down | no | | 6 | sit0 | sit0 | ... | tunnel | down | no | | 7 | usb0 | usb0 | ... | ethernetCsmacd | down | no | | 8 | usb1 | usb1 | ... | ethernetCsmacd | down | no | | 9 | bond0 | bond0 | ... | ethernetCsmacd | up | no | | 10 | usbpt | usbpt | ... | ethernetCsmacd | down | no | +---------+---------+--------+---------+------------------+-------------+---------+ o Duration 0.1895s ##### Module Start: ports-stack ##### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '5'] SQL RUNTIME[0.00041103s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ifStackStatus] CMD EXITCODE[0] CMD RUNTIME[0.032s] STDOUT[ ifStackStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o Duration 0.0363s ##### Module Start: vlans ##### SQL[SELECT * FROM `vlans` WHERE `device_id` = '5';] SQL RUNTIME[0.00071692s] SQL[SELECT * FROM `ports_vlans` WHERE `device_id` = '5';] SQL RUNTIME[0.00063014s] o Q-BRIDGE-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' dot1qVlanStaticName] CMD EXITCODE[0] CMD RUNTIME[0.0374s] STDOUT[ dot1qVlanStaticName = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o Duration 0.0471s ##### Module Start: oids ##### SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '5'] SQL RUNTIME[0.00111794s] SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1'] SQL RUNTIME[0.00069404s] o Duration 0.0058s ##### Module Start: ip-addresses ##### o IP-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAdEntIfIndex] CMD EXITCODE[0] CMD RUNTIME[0.038s] STDOUT[ ipAdEntIfIndex.127.0.0.1 = 1 ipAdEntIfIndex.172.16.14.40 = 9 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAdEntNetMask] CMD EXITCODE[0] CMD RUNTIME[0.0463s] STDOUT[ ipAdEntNetMask.127.0.0.1 = 255.0.0.0 ipAdEntNetMask.172.16.14.40 = 255.255.0.0 ] SNMP STATUS[TRUE] Added 127.0.0.1 .Added 172.16.14.40 . CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAddressIfIndex] CMD EXITCODE[0] CMD RUNTIME[0.031s] STDOUT[ ipAddressIfIndex.ipv4."127.0.0.1" = 1 ipAddressIfIndex.ipv4."172.16.14.40" = 9 ipAddressIfIndex.ipv4."172.16.255.255" = 9 ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = 1 ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:92:fe:ca:0b:91:d7:3e:89" = 9 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAddressType] CMD EXITCODE[0] CMD RUNTIME[0.0314s] STDOUT[ ipAddressType.ipv4."127.0.0.1" = unicast ipAddressType.ipv4."172.16.14.40" = unicast ipAddressType.ipv4."172.16.255.255" = broadcast ipAddressType.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = unicast ipAddressType.ipv6."fe:80:00:00:00:00:00:00:92:fe:ca:0b:91:d7:3e:89" = unicast ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAddressPrefix] CMD EXITCODE[0] CMD RUNTIME[0.0307s] STDOUT[ ipAddressPrefix.ipv4."127.0.0.1" = ipAddressPrefixOrigin.1.ipv4."127.0.0.0".8 ipAddressPrefix.ipv4."172.16.14.40" = ipAddressPrefixOrigin.9.ipv4."172.16.0.0".16 ipAddressPrefix.ipv4."172.16.255.255" = ipAddressPrefixOrigin.9.ipv4."172.16.0.0".16 ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128 ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:92:fe:ca:0b:91:d7:3e:89" = ipAddressPrefixOrigin.9.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipAddressOrigin] CMD EXITCODE[0] CMD RUNTIME[0.03s] STDOUT[ ipAddressOrigin.ipv4."127.0.0.1" = manual ipAddressOrigin.ipv4."172.16.14.40" = manual ipAddressOrigin.ipv4."172.16.255.255" = manual ipAddressOrigin.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = manual ipAddressOrigin.ipv6."fe:80:00:00:00:00:00:00:92:fe:ca:0b:91:d7:3e:89" = linklayer ] SNMP STATUS[TRUE] Added 0000:0000:0000:0000:0000:0000:0000:0001 .Address fe80:0000:0000:0000:92fe:ca0b:91d7:3e89/64 marked as invalid by type [link-local]. Address 'fe80:0000:0000:0000:92fe:ca0b:91d7:3e89/64' skipped as invalid. o IPV6-MIB o LLDP-MIB SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '5'] SQL RUNTIME[0.00095391s] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '5' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00079608s] SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '11'] SQL RUNTIME[0.00062394s] SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '5'] SQL RUNTIME[0.00068498s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '11'] SQL RUNTIME[0.00075817s] SQL[SELECT * FROM `devices` LEFT JOIN `devices_locations` USING (`device_id`) WHERE `device_id` = '5'] SQL RUNTIME[0.00092697s] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '5'] SQL RUNTIME[0.00085878s] SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'] SQL RUNTIME[0.000489s] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '5' AND `ifIndex` = '9' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00048304s] SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '19'] SQL RUNTIME[0.00065613s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '19'] SQL RUNTIME[0.00059891s] SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.0.0/16'] SQL RUNTIME[0.00038004s] SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '5'] SQL RUNTIME[0.0007019s] SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '5'] SQL RUNTIME[0.00057387s] SQL[SELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128'] SQL RUNTIME[0.00053s] SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '5'] SQL RUNTIME[0.00053501s] +---------+---------+-------------+-----------------+---------------------+----------+--------+ | ifIndex | ifDescr | IP: Version | Address | Network | Type | Origin | +---------+---------+-------------+-----------------+---------------------+----------+--------+ | 1 | lo | IPv4 | 127.0.0.1/8 | 127.0.0.0/8 | loopback | | | 9 | bond0 | IPv4 | 172.16.14.40/16 | 172.16.0.0/16 | private | | | 1 | lo | IPv6 | ::1/128 | 0:0:0:0:0:0:0:1/128 | loopback | manual | +---------+---------+-------------+-----------------+---------------------+----------+--------+ o Changes 3 unchanged o Duration 0.2836s ##### Module Start: processors ##### o UCD-SNMP-MIB SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '5' AND `processor_type` != 'ucd-old')] SQL RUNTIME[0.00068808s] CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ssCpuIdle.0] CMD EXITCODE[0] CMD RUNTIME[0.0277s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o HOST-RESOURCES-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' hrProcessorLoad] CMD EXITCODE[0] CMD RUNTIME[0.0234s] STDOUT[ hrProcessorLoad = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `processors` WHERE `device_id` = '5'] SQL RUNTIME[0.0010612s] o Duration 0.0643s ##### Module Start: mempools ##### o UCD-SNMP-MIB CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0] CMD EXITCODE[0] CMD RUNTIME[0.0275s] STDOUT[ memTotalReal.0 = No Such Object available on this agent at this OID memAvailReal.0 = No Such Object available on this agent at this OID memBuffer.0 = No Such Object available on this agent at this OID memCached.0 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response] SNMP STATUS[FALSE] o HOST-RESOURCES-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' hrStorageEntry] CMD EXITCODE[0] CMD RUNTIME[0.0309s] STDOUT[ hrStorageEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `mempools` WHERE `device_id` = '5'] SQL RUNTIME[0.00121498s] o Duration 0.0718s ##### Module Start: inventory ##### o ENTITY-MIB ENTITY-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'gis01-idrac':'161' entPhysicalEntry] CMD EXITCODE[0] CMD RUNTIME[0.1s] STDOUT[ entPhysicalEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o HOST-RESOURCES-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' hrDeviceEntry] CMD EXITCODE[0] CMD RUNTIME[0.0301s] STDOUT[ hrDeviceEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' hrProcessorEntry] CMD EXITCODE[0] CMD RUNTIME[0.0293s] STDOUT[ hrProcessorEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '5'] SQL RUNTIME[0.00098014s] o DELL-RAC-MIB CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsProductType.0] CMD EXITCODE[0] CMD RUNTIME[0.0957s] STDOUT[ 0 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '5'] SQL RUNTIME[0.00107002s] o Duration 0.2819s ##### Module Start: printersupplies ##### SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '5'] SQL RUNTIME[0.00071192s] o Duration 0.0036s ##### Module Start: sensors ##### o IDRAC-MIB-SMIv2 temperatureProbeReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeReading] CMD EXITCODE[0] CMD RUNTIME[0.0527s] STDOUT[ temperatureProbeReading.1.1 = 300 temperatureProbeReading.1.2 = 200 temperatureProbeReading.1.3 = 260 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeLocationName] CMD EXITCODE[0] CMD RUNTIME[0.0755s] STDOUT[ temperatureProbeLocationName.1.1 = "CPU1 Temp" temperatureProbeLocationName.1.2 = "System Board Inlet Temp" temperatureProbeLocationName.1.3 = "System Board Exhaust Temp" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLocationName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeLowerCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.075s] STDOUT[ temperatureProbeLowerCriticalThreshold.1.1 = 30 temperatureProbeLowerCriticalThreshold.1.2 = -70 temperatureProbeLowerCriticalThreshold.1.3 = 30 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLowerCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeLowerNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0728s] STDOUT[ temperatureProbeLowerNonCriticalThreshold.1.2 = 30 temperatureProbeLowerNonCriticalThreshold.1.3 = 80 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLowerNonCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeUpperNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0475s] STDOUT[ temperatureProbeUpperNonCriticalThreshold.1.2 = 380 temperatureProbeUpperNonCriticalThreshold.1.3 = 750 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeUpperNonCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeUpperCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.058s] STDOUT[ temperatureProbeUpperCriticalThreshold.1.1 = 950 temperatureProbeUpperCriticalThreshold.1.2 = 420 temperatureProbeUpperCriticalThreshold.1.3 = 800 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeUpperCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' temperatureProbeStateSettings] CMD EXITCODE[0] CMD RUNTIME[0.0463s] STDOUT[ temperatureProbeStateSettings.1.1 = enabled temperatureProbeStateSettings.1.2 = enabled temperatureProbeStateSettings.1.3 = enabled ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeStateSettings TRUE String 'CPU1 Temp' transformed by action [replace] to: 'CPU1 ' Discover sensor: [class: temperature, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: CPU1 , scale: 0.1, limits: (3, , , 95), CURRENT: 30, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.1')] SQL RUNTIME[0.00162101s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.1'] SQL RUNTIME[0.0011611s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00060701s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00055194s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-temperature-temperatureProbeReading-1.1.rrd' TRUE String 'System Board Inlet Temp' transformed by action [replace] to: 'System Board Inlet ' Discover sensor: [class: temperature, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: System Board Inlet , scale: 0.1, limits: (-7, 3, 38, 42), CURRENT: 20, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.2')] SQL RUNTIME[0.00103402s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.2'] SQL RUNTIME[0.00140285s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '29' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00061607s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '29' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00051284s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-temperature-temperatureProbeReading-1.2.rrd' TRUE String 'System Board Exhaust Temp' transformed by action [replace] to: 'System Board Exhaust ' Discover sensor: [class: temperature, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: System Board Exhaust , scale: 0.1, limits: (3, 8, 75, 80), CURRENT: 26, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.3')] SQL RUNTIME[0.00079584s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.3'] SQL RUNTIME[0.00085306s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '30' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00047898s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '30' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00053215s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-temperature-temperatureProbeReading-1.3.rrd' ] coolingDeviceReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceReading] CMD EXITCODE[0] CMD RUNTIME[0.0497s] STDOUT[ coolingDeviceReading.1.1 = 13440 coolingDeviceReading.1.2 = 13560 coolingDeviceReading.1.3 = 13320 coolingDeviceReading.1.4 = 13320 coolingDeviceReading.1.5 = 12600 coolingDeviceReading.1.6 = 12600 coolingDeviceReading.1.7 = 12720 coolingDeviceReading.1.8 = 12720 coolingDeviceReading.1.9 = 13440 coolingDeviceReading.1.10 = 13440 coolingDeviceReading.1.11 = 13440 coolingDeviceReading.1.12 = 13320 coolingDeviceReading.1.13 = 12840 coolingDeviceReading.1.14 = 12720 coolingDeviceReading.1.15 = 12720 coolingDeviceReading.1.16 = 12600 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceLocationName] CMD EXITCODE[0] CMD RUNTIME[0.073s] STDOUT[ coolingDeviceLocationName.1.1 = "System Board Fan1A" coolingDeviceLocationName.1.2 = "System Board Fan2A" coolingDeviceLocationName.1.3 = "System Board Fan3A" coolingDeviceLocationName.1.4 = "System Board Fan4A" coolingDeviceLocationName.1.5 = "System Board Fan1B" coolingDeviceLocationName.1.6 = "System Board Fan2B" coolingDeviceLocationName.1.7 = "System Board Fan3B" coolingDeviceLocationName.1.8 = "System Board Fan4B" coolingDeviceLocationName.1.9 = "System Board Fan1C" coolingDeviceLocationName.1.10 = "System Board Fan2C" coolingDeviceLocationName.1.11 = "System Board Fan3C" coolingDeviceLocationName.1.12 = "System Board Fan4C" coolingDeviceLocationName.1.13 = "System Board Fan1D" coolingDeviceLocationName.1.14 = "System Board Fan2D" coolingDeviceLocationName.1.15 = "System Board Fan3D" coolingDeviceLocationName.1.16 = "System Board Fan4D" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLocationName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceLowerCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0651s] STDOUT[ coolingDeviceLowerCriticalThreshold.1.1 = 480 coolingDeviceLowerCriticalThreshold.1.2 = 480 coolingDeviceLowerCriticalThreshold.1.3 = 480 coolingDeviceLowerCriticalThreshold.1.4 = 480 coolingDeviceLowerCriticalThreshold.1.5 = 480 coolingDeviceLowerCriticalThreshold.1.6 = 480 coolingDeviceLowerCriticalThreshold.1.7 = 480 coolingDeviceLowerCriticalThreshold.1.8 = 480 coolingDeviceLowerCriticalThreshold.1.9 = 480 coolingDeviceLowerCriticalThreshold.1.10 = 480 coolingDeviceLowerCriticalThreshold.1.11 = 480 coolingDeviceLowerCriticalThreshold.1.12 = 480 coolingDeviceLowerCriticalThreshold.1.13 = 480 coolingDeviceLowerCriticalThreshold.1.14 = 480 coolingDeviceLowerCriticalThreshold.1.15 = 480 coolingDeviceLowerCriticalThreshold.1.16 = 480 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLowerCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceLowerNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0649s] STDOUT[ coolingDeviceLowerNonCriticalThreshold.1.1 = 840 coolingDeviceLowerNonCriticalThreshold.1.2 = 840 coolingDeviceLowerNonCriticalThreshold.1.3 = 840 coolingDeviceLowerNonCriticalThreshold.1.4 = 840 coolingDeviceLowerNonCriticalThreshold.1.5 = 840 coolingDeviceLowerNonCriticalThreshold.1.6 = 840 coolingDeviceLowerNonCriticalThreshold.1.7 = 840 coolingDeviceLowerNonCriticalThreshold.1.8 = 840 coolingDeviceLowerNonCriticalThreshold.1.9 = 840 coolingDeviceLowerNonCriticalThreshold.1.10 = 840 coolingDeviceLowerNonCriticalThreshold.1.11 = 840 coolingDeviceLowerNonCriticalThreshold.1.12 = 840 coolingDeviceLowerNonCriticalThreshold.1.13 = 840 coolingDeviceLowerNonCriticalThreshold.1.14 = 840 coolingDeviceLowerNonCriticalThreshold.1.15 = 840 coolingDeviceLowerNonCriticalThreshold.1.16 = 840 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLowerNonCriticalThreshold CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceUpperNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.064s] STDOUT[ coolingDeviceUpperNonCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceUpperCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0602s] STDOUT[ coolingDeviceUpperCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' coolingDeviceStateSettings] CMD EXITCODE[0] CMD RUNTIME[0.0845s] STDOUT[ coolingDeviceStateSettings.1.1 = enabled coolingDeviceStateSettings.1.2 = enabled coolingDeviceStateSettings.1.3 = enabled coolingDeviceStateSettings.1.4 = enabled coolingDeviceStateSettings.1.5 = enabled coolingDeviceStateSettings.1.6 = enabled coolingDeviceStateSettings.1.7 = enabled coolingDeviceStateSettings.1.8 = enabled coolingDeviceStateSettings.1.9 = enabled coolingDeviceStateSettings.1.10 = enabled coolingDeviceStateSettings.1.11 = enabled coolingDeviceStateSettings.1.12 = enabled coolingDeviceStateSettings.1.13 = enabled coolingDeviceStateSettings.1.14 = enabled coolingDeviceStateSettings.1.15 = enabled coolingDeviceStateSettings.1.16 = enabled ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceStateSettings TRUE String 'System Board Fan1A' transformed by action [replace] to: 'System Board Fan1A' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan1A, scale: 1, limits: (480, 840, , ), CURRENT: 13440, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.1')] SQL RUNTIME[0.00164485s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.1'] SQL RUNTIME[0.00131798s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '31' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00058293s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '31' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00060296s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.1.rrd' TRUE String 'System Board Fan2A' transformed by action [replace] to: 'System Board Fan2A' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan2A, scale: 1, limits: (480, 840, , ), CURRENT: 13560, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.2')] SQL RUNTIME[0.00092697s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.2'] SQL RUNTIME[0.00109506s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '32' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00053191s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '32' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00050712s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.2.rrd' TRUE String 'System Board Fan3A' transformed by action [replace] to: 'System Board Fan3A' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan3A, scale: 1, limits: (480, 840, , ), CURRENT: 13320, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.3')] SQL RUNTIME[0.00070715s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.3'] SQL RUNTIME[0.00085807s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '33' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00044894s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '33' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.000458s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.3.rrd' TRUE String 'System Board Fan4A' transformed by action [replace] to: 'System Board Fan4A' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.4, index: 1.4, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan4A, scale: 1, limits: (480, 840, , ), CURRENT: 13320, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.4')] SQL RUNTIME[0.00068402s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.4'] SQL RUNTIME[0.00081706s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '34' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00055289s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '34' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00043201s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.4.rrd' TRUE String 'System Board Fan1B' transformed by action [replace] to: 'System Board Fan1B' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.5, index: 1.5, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan1B, scale: 1, limits: (480, 840, , ), CURRENT: 12600, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.5')] SQL RUNTIME[0.00064898s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.5'] SQL RUNTIME[0.00066304s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '35' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00039601s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '35' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00035691s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.5.rrd' TRUE String 'System Board Fan2B' transformed by action [replace] to: 'System Board Fan2B' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.6, index: 1.6, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan2B, scale: 1, limits: (480, 840, , ), CURRENT: 12600, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.6')] SQL RUNTIME[0.00056791s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.6'] SQL RUNTIME[0.00072598s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '36' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00037003s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '36' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00033307s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.6.rrd' TRUE String 'System Board Fan3B' transformed by action [replace] to: 'System Board Fan3B' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.7, index: 1.7, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan3B, scale: 1, limits: (480, 840, , ), CURRENT: 12720, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.7')] SQL RUNTIME[0.00054598s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.7'] SQL RUNTIME[0.00071192s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '37' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00030684s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '37' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00027084s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.7.rrd' TRUE String 'System Board Fan4B' transformed by action [replace] to: 'System Board Fan4B' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.8, index: 1.8, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan4B, scale: 1, limits: (480, 840, , ), CURRENT: 12720, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.8')] SQL RUNTIME[0.00051713s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.8'] SQL RUNTIME[0.00067496s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '38' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00034499s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '38' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00028205s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.8.rrd' TRUE String 'System Board Fan1C' transformed by action [replace] to: 'System Board Fan1C' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.9, index: 1.9, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan1C, scale: 1, limits: (480, 840, , ), CURRENT: 13440, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.9')] SQL RUNTIME[0.00053215s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.9'] SQL RUNTIME[0.00062513s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '39' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00032902s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '39' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00031781s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.9.rrd' TRUE String 'System Board Fan2C' transformed by action [replace] to: 'System Board Fan2C' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.10, index: 1.10, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan2C, scale: 1, limits: (480, 840, , ), CURRENT: 13440, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.10')] SQL RUNTIME[0.00047779s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.10'] SQL RUNTIME[0.00051808s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '40' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00028205s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '40' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00027299s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.10.rrd' TRUE String 'System Board Fan3C' transformed by action [replace] to: 'System Board Fan3C' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.11, index: 1.11, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan3C, scale: 1, limits: (480, 840, , ), CURRENT: 13440, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.11')] SQL RUNTIME[0.00049496s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.11'] SQL RUNTIME[0.00054908s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00028205s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '41' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00026011s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.11.rrd' TRUE String 'System Board Fan4C' transformed by action [replace] to: 'System Board Fan4C' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.12, index: 1.12, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan4C, scale: 1, limits: (480, 840, , ), CURRENT: 13320, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.12')] SQL RUNTIME[0.00046992s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.12'] SQL RUNTIME[0.00057602s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '42' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.000278s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '42' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00028396s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.12.rrd' TRUE String 'System Board Fan1D' transformed by action [replace] to: 'System Board Fan1D' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.13, index: 1.13, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan1D, scale: 1, limits: (480, 840, , ), CURRENT: 12840, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.13')] SQL RUNTIME[0.00041199s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.13'] SQL RUNTIME[0.00049591s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '43' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00026202s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '43' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00028014s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.13.rrd' TRUE String 'System Board Fan2D' transformed by action [replace] to: 'System Board Fan2D' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.14, index: 1.14, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan2D, scale: 1, limits: (480, 840, , ), CURRENT: 12720, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.14')] SQL RUNTIME[0.00040007s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.14'] SQL RUNTIME[0.00046492s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '44' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00025105s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '44' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023413s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.14.rrd' TRUE String 'System Board Fan3D' transformed by action [replace] to: 'System Board Fan3D' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.15, index: 1.15, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan3D, scale: 1, limits: (480, 840, , ), CURRENT: 12720, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.15')] SQL RUNTIME[0.00041604s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.15'] SQL RUNTIME[0.00044513s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '45' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00025105s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '45' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023293s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.15.rrd' TRUE String 'System Board Fan4D' transformed by action [replace] to: 'System Board Fan4D' Discover sensor: [class: fanspeed, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.16, index: 1.16, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan4D, scale: 1, limits: (480, 840, , ), CURRENT: 12600, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.16')] SQL RUNTIME[0.00040293s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.16'] SQL RUNTIME[0.00055099s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '46' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00027418s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '46' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.0002749s] .RRD old file not found: '/opt/observium/rrd/gis01-idrac/sensor-fanspeed-coolingDeviceReading-1.16.rrd' ] voltageProbeReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeReading] CMD EXITCODE[0] CMD RUNTIME[0.0529s] STDOUT[ voltageProbeReading.1.1 = 230000 voltageProbeReading.1.2 = 230000 voltageProbeReading.1.20 = 1810 voltageProbeReading.1.21 = 1030 voltageProbeReading.1.22 = 1130 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeLocationName] CMD EXITCODE[0] CMD RUNTIME[0.0971s] STDOUT[ voltageProbeLocationName.1.1 = "PS1 Voltage 1" voltageProbeLocationName.1.2 = "PS2 Voltage 2" voltageProbeLocationName.1.3 = "System Board Pfault Fail Safe" voltageProbeLocationName.1.4 = "System Board PS1 PG FAIL" voltageProbeLocationName.1.5 = "System Board PS2 PG FAIL" voltageProbeLocationName.1.6 = "System Board BP0 PG" voltageProbeLocationName.1.7 = "System Board BP1 PG" voltageProbeLocationName.1.8 = "System Board BP2 PG" voltageProbeLocationName.1.9 = "System Board 1V05 SW PG" voltageProbeLocationName.1.10 = "System Board 3.3V A PG" voltageProbeLocationName.1.11 = "System Board 5V SW PG" voltageProbeLocationName.1.12 = "System Board BMC SW PG" voltageProbeLocationName.1.13 = "System Board OCP1 PG" voltageProbeLocationName.1.14 = "CPU1 VCCD PG" voltageProbeLocationName.1.15 = "CPU1 HBM VPP PG" voltageProbeLocationName.1.16 = "CPU1 VCCFA PG" voltageProbeLocationName.1.17 = "CPU1 FIVRA PG" voltageProbeLocationName.1.18 = "CPU1 INFAON PG" voltageProbeLocationName.1.19 = "CPU1 PVNN PG" voltageProbeLocationName.1.20 = "CPU1 VCCIN VR" voltageProbeLocationName.1.21 = "CPU1 VCCFA VR" voltageProbeLocationName.1.22 = "CPU1 VCCD VR" voltageProbeLocationName.1.23 = "CPU1 VCCIN PG" voltageProbeLocationName.1.24 = "System Board PUCK COMBINED PG" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeLocationName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeLowerCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0575s] STDOUT[ voltageProbeLowerCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeLowerNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.0619s] STDOUT[ voltageProbeLowerNonCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeUpperNonCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.1102s] STDOUT[ voltageProbeUpperNonCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeUpperCriticalThreshold] CMD EXITCODE[0] CMD RUNTIME[0.1089s] STDOUT[ voltageProbeUpperCriticalThreshold = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeStateSettings] CMD EXITCODE[0] CMD RUNTIME[0.0783s] STDOUT[ voltageProbeStateSettings.1.1 = enabled voltageProbeStateSettings.1.2 = enabled voltageProbeStateSettings.1.3 = enabled voltageProbeStateSettings.1.4 = enabled voltageProbeStateSettings.1.5 = enabled voltageProbeStateSettings.1.6 = enabled voltageProbeStateSettings.1.7 = enabled voltageProbeStateSettings.1.8 = enabled voltageProbeStateSettings.1.9 = enabled voltageProbeStateSettings.1.10 = enabled voltageProbeStateSettings.1.11 = enabled voltageProbeStateSettings.1.12 = enabled voltageProbeStateSettings.1.13 = enabled voltageProbeStateSettings.1.14 = enabled voltageProbeStateSettings.1.15 = enabled voltageProbeStateSettings.1.16 = enabled voltageProbeStateSettings.1.17 = enabled voltageProbeStateSettings.1.18 = enabled voltageProbeStateSettings.1.19 = enabled voltageProbeStateSettings.1.20 = enabled voltageProbeStateSettings.1.21 = enabled voltageProbeStateSettings.1.22 = enabled voltageProbeStateSettings.1.23 = enabled voltageProbeStateSettings.1.24 = enabled ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeStateSettings TRUE String 'PS1 Voltage 1' transformed by action [replace] to: 'Power supply 1' Discover sensor: [class: voltage, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: Power supply 1, scale: 0.001, limits: (, , , ), CURRENT: 230, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.1')] SQL RUNTIME[0.00158691s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.1'] SQL RUNTIME[0.00125003s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '47' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00067306s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '47' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00078082s] .TRUE String 'PS2 Voltage 2' transformed by action [replace] to: 'Power supply 2' Discover sensor: [class: voltage, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: Power supply 2, scale: 0.001, limits: (, , , ), CURRENT: 230, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.2')] SQL RUNTIME[0.00110602s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.2'] SQL RUNTIME[0.00096703s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '48' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00068712s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '48' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00055289s] .TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE String 'CPU1 VCCIN VR' transformed by action [replace] to: 'CPU1 VCCIN VR' Discover sensor: [class: voltage, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.20, index: 1.20, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: CPU1 VCCIN VR, scale: 0.001, limits: (, , , ), CURRENT: 1.81, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.20')] SQL RUNTIME[0.00068188s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.20'] SQL RUNTIME[0.00073886s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '49' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00046897s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '49' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00039887s] .TRUE String 'CPU1 VCCFA VR' transformed by action [replace] to: 'CPU1 VCCFA VR' Discover sensor: [class: voltage, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.21, index: 1.21, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: CPU1 VCCFA VR, scale: 0.001, limits: (, , , ), CURRENT: 1.03, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.21')] SQL RUNTIME[0.00074601s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.21'] SQL RUNTIME[0.00073099s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '50' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.0004282s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '50' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00038099s] .TRUE String 'CPU1 VCCD VR' transformed by action [replace] to: 'CPU1 VCCD VR' Discover sensor: [class: voltage, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.22, index: 1.22, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: CPU1 VCCD VR, scale: 0.001, limits: (, , , ), CURRENT: 1.13, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.22')] SQL RUNTIME[0.00065613s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.22'] SQL RUNTIME[0.00066209s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '51' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00034809s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '51' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00039601s] .TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. TRUE Excluded by sensor 'voltageProbeReading' value '' is not numeric. ] amperageProbeReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' amperageProbeTable] CMD EXITCODE[0] CMD RUNTIME[0.0676s] STDOUT[ amperageProbechassisIndex.1.1 = 1 amperageProbechassisIndex.1.2 = 1 amperageProbechassisIndex.1.3 = 1 amperageProbeIndex.1.1 = 1 amperageProbeIndex.1.2 = 2 amperageProbeIndex.1.3 = 3 amperageProbeStateCapabilities.1.1 = 0 amperageProbeStateCapabilities.1.2 = 0 amperageProbeStateCapabilities.1.3 = 0 amperageProbeStateSettings.1.1 = enabled amperageProbeStateSettings.1.2 = enabled amperageProbeStateSettings.1.3 = enabled amperageProbeStatus.1.1 = ok amperageProbeStatus.1.2 = ok amperageProbeStatus.1.3 = ok amperageProbeReading.1.1 = 8 amperageProbeReading.1.2 = 2 amperageProbeReading.1.3 = 198 amperageProbeType.1.1 = amperageProbeTypeIsPowerSupplyAmps amperageProbeType.1.2 = amperageProbeTypeIsPowerSupplyAmps amperageProbeType.1.3 = amperageProbeTypeIsSystemWatts amperageProbeLocationName.1.1 = "PS1 Current 1" amperageProbeLocationName.1.2 = "PS2 Current 2" amperageProbeLocationName.1.3 = "System Board Pwr Consumption" amperageProbeUpperCriticalThreshold.1.3 = 1254 amperageProbeUpperNonCriticalThreshold.1.3 = 1155 amperageProbeProbeCapabilities.1.1 = 0 amperageProbeProbeCapabilities.1.2 = 0 amperageProbeProbeCapabilities.1.3 = 5 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::amperageProbeTable map_class found: amperageProbeTypeIsPowerSupplyAmps - current Scale mapped from value [amperageProbeTypeIsPowerSupplyAmps] to 0.1 String 'PS1 Current 1' transformed by action [replace] to: 'Power supply 1' Discover sensor: [class: current, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: Power supply 1, scale: 0.1, limits: (, , , ), CURRENT: 0.8, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.1')] SQL RUNTIME[0.00124502s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.1'] SQL RUNTIME[0.00127888s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '52' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00080705s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '52' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.000664s] .map_class found: amperageProbeTypeIsPowerSupplyAmps - current Scale mapped from value [amperageProbeTypeIsPowerSupplyAmps] to 0.1 String 'PS2 Current 2' transformed by action [replace] to: 'Power supply 2' Discover sensor: [class: current, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: Power supply 2, scale: 0.1, limits: (, , , ), CURRENT: 0.2, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.2')] SQL RUNTIME[0.00109196s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.2'] SQL RUNTIME[0.00102901s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '53' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00064898s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '53' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00047112s] .map_class found: amperageProbeTypeIsSystemWatts - power Scale mapped from value [amperageProbeTypeIsSystemWatts] to 1 String 'System Board Pwr Consumption' transformed by action [replace] to: 'System Board' Discover sensor: [class: power, device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: System Board, scale: 1, limits: (, , 1155, 1254), CURRENT: 198, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.3')] SQL RUNTIME[0.00093317s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '5' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.3'] SQL RUNTIME[0.00078607s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '54' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00048208s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '54' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00043416s] .] o IDRAC-MIB-SMIv2 globalSystemStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' globalSystemStatus] CMD EXITCODE[0] CMD RUNTIME[0.0597s] STDOUT[ globalSystemStatus.0 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::globalSystemStatus Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.2.1.0, index: 0, type: ObjectStatusEnum, descr: Overall System Status, CURRENT: 3, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalSystemStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00133991s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalSystemStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00132895s] .] systemLCDStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' systemLCDStatus] CMD EXITCODE[0] CMD RUNTIME[0.0582s] STDOUT[ systemLCDStatus.0 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::systemLCDStatus Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.2.2.0, index: 0, type: ObjectStatusEnum, descr: System LCD Status, CURRENT: 3, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLCDStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00141788s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLCDStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00125694s] .] globalStorageStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' globalStorageStatus] CMD EXITCODE[0] CMD RUNTIME[0.0571s] STDOUT[ globalStorageStatus.0 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::globalStorageStatus Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.2.3.0, index: 0, type: ObjectStatusEnum, descr: Global Storage Status, CURRENT: 3, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalStorageStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00153112s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalStorageStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00126386s] .] systemPowerState [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' systemPowerState] CMD EXITCODE[0] CMD RUNTIME[0.0555s] STDOUT[ systemPowerState.0 = on ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::systemPowerState Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.2.4.0, index: 0, type: PowerStateStatusEnum, descr: System Power State, CURRENT: 4, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemPowerState' AND `status_type` = 'PowerStateStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00121713s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemPowerState' AND `status_type` = 'PowerStateStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00105596s] .] systemLockdownMode [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' systemLockdownMode] CMD EXITCODE[0] CMD RUNTIME[0.0622s] STDOUT[ systemLockdownMode.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::systemLockdownMode Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.1.3.20.0, index: 0, type: SystemLockdownModeEnum, descr: System Lockdown State, CURRENT: 0, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLockdownMode' AND `status_type` = 'SystemLockdownModeEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00128508s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLockdownMode' AND `status_type` = 'SystemLockdownModeEnum' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00114894s] .] voltageProbeDiscreteReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeDiscreteReading] CMD EXITCODE[0] CMD RUNTIME[0.1001s] STDOUT[ voltageProbeDiscreteReading.1.3 = voltageIsGood voltageProbeDiscreteReading.1.4 = voltageIsGood voltageProbeDiscreteReading.1.5 = voltageIsGood voltageProbeDiscreteReading.1.6 = voltageIsGood voltageProbeDiscreteReading.1.7 = voltageIsGood voltageProbeDiscreteReading.1.8 = voltageIsGood voltageProbeDiscreteReading.1.9 = voltageIsGood voltageProbeDiscreteReading.1.10 = voltageIsGood voltageProbeDiscreteReading.1.11 = voltageIsGood voltageProbeDiscreteReading.1.12 = voltageIsGood voltageProbeDiscreteReading.1.13 = voltageIsGood voltageProbeDiscreteReading.1.14 = voltageIsGood voltageProbeDiscreteReading.1.15 = voltageIsGood voltageProbeDiscreteReading.1.16 = voltageIsGood voltageProbeDiscreteReading.1.17 = voltageIsGood voltageProbeDiscreteReading.1.18 = voltageIsGood voltageProbeDiscreteReading.1.19 = voltageIsGood voltageProbeDiscreteReading.1.23 = voltageIsGood voltageProbeDiscreteReading.1.24 = voltageIsGood ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeDiscreteReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' voltageProbeType] CMD EXITCODE[0] CMD RUNTIME[0.0666s] STDOUT[ voltageProbeType.1.1 = voltageProbeTypeIsPSVoltage voltageProbeType.1.2 = voltageProbeTypeIsPSVoltage voltageProbeType.1.3 = voltageProbeTypeIsDiscrete voltageProbeType.1.4 = voltageProbeTypeIsDiscrete voltageProbeType.1.5 = voltageProbeTypeIsDiscrete voltageProbeType.1.6 = voltageProbeTypeIsDiscrete voltageProbeType.1.7 = voltageProbeTypeIsDiscrete voltageProbeType.1.8 = voltageProbeTypeIsDiscrete voltageProbeType.1.9 = voltageProbeTypeIsDiscrete voltageProbeType.1.10 = voltageProbeTypeIsDiscrete voltageProbeType.1.11 = voltageProbeTypeIsDiscrete voltageProbeType.1.12 = voltageProbeTypeIsDiscrete voltageProbeType.1.13 = voltageProbeTypeIsDiscrete voltageProbeType.1.14 = voltageProbeTypeIsDiscrete voltageProbeType.1.15 = voltageProbeTypeIsDiscrete voltageProbeType.1.16 = voltageProbeTypeIsDiscrete voltageProbeType.1.17 = voltageProbeTypeIsDiscrete voltageProbeType.1.18 = voltageProbeTypeIsDiscrete voltageProbeType.1.19 = voltageProbeTypeIsDiscrete voltageProbeType.1.20 = voltageProbeTypeIsPSVoltage voltageProbeType.1.21 = voltageProbeTypeIsPSVoltage voltageProbeType.1.22 = voltageProbeTypeIsPSVoltage voltageProbeType.1.23 = voltageProbeTypeIsDiscrete voltageProbeType.1.24 = voltageProbeTypeIsDiscrete ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeType Get cached Table OID: IDRAC-MIB-SMIv2::voltageProbeLocationName NOT TRUE Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete] NOT TRUE Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete] TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.3, index: 1.3, type: DellVoltageDiscreteReading, descr: Voltage System Board Pfault Fail Safe, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.3' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00163293s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.3' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00132799s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.4, index: 1.4, type: DellVoltageDiscreteReading, descr: Voltage System Board PS1 PG FAIL, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.4' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00097609s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.4' AND `poller_type`= 'snmp'] SQL RUNTIME[0.0012641s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.5, index: 1.5, type: DellVoltageDiscreteReading, descr: Voltage System Board PS2 PG FAIL, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.5' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00091505s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.5' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00097299s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.6, index: 1.6, type: DellVoltageDiscreteReading, descr: Voltage System Board BP0 PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.6' AND `poller_type`= 'snmp')] SQL RUNTIME[0.000772s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.6' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00064898s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.7, index: 1.7, type: DellVoltageDiscreteReading, descr: Voltage System Board BP1 PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.7' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00058198s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.7' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00065112s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.8, index: 1.8, type: DellVoltageDiscreteReading, descr: Voltage System Board BP2 PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.8' AND `poller_type`= 'snmp')] SQL RUNTIME[0.000561s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.8' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00075603s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.9, index: 1.9, type: DellVoltageDiscreteReading, descr: Voltage System Board 1V05 SW PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.9' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00051093s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.9' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00056887s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.10, index: 1.10, type: DellVoltageDiscreteReading, descr: Voltage System Board 3.3V A PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.10' AND `poller_type`= 'snmp')] SQL RUNTIME[0.000494s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.10' AND `poller_type`= 'snmp'] SQL RUNTIME[0.000561s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.11, index: 1.11, type: DellVoltageDiscreteReading, descr: Voltage System Board 5V SW PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.11' AND `poller_type`= 'snmp')] SQL RUNTIME[0.000489s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.11' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00059414s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.12, index: 1.12, type: DellVoltageDiscreteReading, descr: Voltage System Board BMC SW PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.12' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00050116s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.12' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00055599s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.13, index: 1.13, type: DellVoltageDiscreteReading, descr: Voltage System Board OCP1 PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.13' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00049496s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.13' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00066209s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.14, index: 1.14, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VCCD PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.14' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00054908s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.14' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00070691s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.15, index: 1.15, type: DellVoltageDiscreteReading, descr: Voltage CPU1 HBM VPP PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.15' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00051808s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.15' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00050402s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.16, index: 1.16, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VCCFA PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.16' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00043488s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.16' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00050092s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.17, index: 1.17, type: DellVoltageDiscreteReading, descr: Voltage CPU1 FIVRA PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.17' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00043297s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.17' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00047016s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.18, index: 1.18, type: DellVoltageDiscreteReading, descr: Voltage CPU1 INFAON PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.18' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00053191s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.18' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00049305s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.19, index: 1.19, type: DellVoltageDiscreteReading, descr: Voltage CPU1 PVNN PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.19' AND `poller_type`= 'snmp')] SQL RUNTIME[0.0005641s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.19' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00046301s] .NOT TRUE Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete] NOT TRUE Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete] NOT TRUE Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete] TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.23, index: 1.23, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VCCIN PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.23' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00078201s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.23' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00118804s] .TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.24, index: 1.24, type: DellVoltageDiscreteReading, descr: Voltage System Board PUCK COMBINED PG, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.24' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00100899s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.24' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00102901s] .] powerSupplyStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' powerSupplyStatus] CMD EXITCODE[0] CMD RUNTIME[0.0454s] STDOUT[ powerSupplyStatus.1.1 = ok powerSupplyStatus.1.2 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyStatus CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' powerSupplyLocationName] CMD EXITCODE[0] CMD RUNTIME[0.0491s] STDOUT[ powerSupplyLocationName.1.1 = "PS1 Status" powerSupplyLocationName.1.2 = "PS2 Status" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyLocationName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' powerSupplyStateSettingsUnique] CMD EXITCODE[0] CMD RUNTIME[0.0473s] STDOUT[ powerSupplyStateSettingsUnique.1.1 = acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline powerSupplyStateSettingsUnique.1.2 = acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyStateSettingsUnique TRUE String 'PS1 Status' transformed by action [replace] to: 'Power supply 1 Status' Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.12.1.5.1.1, index: 1.1, type: ObjectStatusEnum, descr: Power supply 1 Status, CURRENT: 3, , powersupply] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.1' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00163198s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00141597s] .TRUE String 'PS2 Status' transformed by action [replace] to: 'Power supply 2 Status' Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.12.1.5.1.2, index: 1.2, type: ObjectStatusEnum, descr: Power supply 2 Status, CURRENT: 3, , powersupply] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.2' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00117803s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.2' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00107694s] .] chassisStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' chassisStatus] CMD EXITCODE[0] CMD RUNTIME[0.1368s] STDOUT[ chassisStatus.1 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::chassisStatus CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' chassisName] CMD EXITCODE[0] CMD RUNTIME[0.0867s] STDOUT[ chassisName.1 = "Main System Chassis" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::chassisName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' chassisStateSettings] CMD EXITCODE[0] CMD RUNTIME[0.1412s] STDOUT[ chassisStateSettings.1 = enabled ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::chassisStateSettings TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.300.10.1.4.1, index: 1, type: ObjectStatusEnum, descr: Main System Chassis, CURRENT: 3, , chassis] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'chassisStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1' AND `poller_type`= 'snmp')] SQL RUNTIME[0.0016861s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'chassisStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00133801s] .] intrusionReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' intrusionReading] CMD EXITCODE[0] CMD RUNTIME[0.0491s] STDOUT[ intrusionReading.1.1 = chassisNotBreached ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' intrusionLocationName] CMD EXITCODE[0] CMD RUNTIME[0.0504s] STDOUT[ intrusionLocationName.1.1 = "System Board Intrusion" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionLocationName CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' intrusionStateSettings] CMD EXITCODE[0] CMD RUNTIME[0.0472s] STDOUT[ intrusionStateSettings.1.1 = enabled ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionStateSettings TRUE Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.300.70.1.6.1.1, index: 1.1, type: DellIntrusionReading, descr: System Board Intrusion, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'intrusionReading' AND `status_type` = 'DellIntrusionReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp')] SQL RUNTIME[0.001302s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'intrusionReading' AND `status_type` = 'DellIntrusionReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00167894s] .] systemBatteryReading [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' systemBatteryReading] CMD EXITCODE[0] CMD RUNTIME[0.0447s] STDOUT[ systemBatteryReading.1.1 = presenceDetected systemBatteryReading.1.2 = presenceDetected ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::systemBatteryReading CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' systemBatteryLocationName] CMD EXITCODE[0] CMD RUNTIME[0.0484s] STDOUT[ systemBatteryLocationName.1.1 = "System Board CMOS Battery" systemBatteryLocationName.1.2 = "PERC1 ROMB Battery" ] SNMP STATUS[TRUE] Store in cache Table OID: IDRAC-MIB-SMIv2::systemBatteryLocationName Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.50.1.6.1.1, index: 1.1, type: DellBatteryReading, descr: System Board CMOS Battery, CURRENT: 4, , battery] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00139213s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00099182s] .Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.5.4.600.50.1.6.1.2, index: 1.2, type: DellBatteryReading, descr: PERC1 ROMB Battery, CURRENT: 4, , battery] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.2' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00096393s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.2' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00089192s] .] o DELL-RAC-MIB drsChassisFrontPanelAmbientTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsChassisFrontPanelAmbientTemperature] CMD EXITCODE[0] CMD RUNTIME[0.3215s] STDOUT[ drsChassisFrontPanelAmbientTemperature = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsCMCAmbientTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsCMCAmbientTemperature] CMD EXITCODE[0] CMD RUNTIME[0.2979s] STDOUT[ drsCMCAmbientTemperature = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsCMCProcessorTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsCMCProcessorTemperature] CMD EXITCODE[0] CMD RUNTIME[0.3116s] STDOUT[ drsCMCProcessorTemperature = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] o DELL-RAC-MIB drsGlobalSystemStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsGlobalSystemStatus] CMD EXITCODE[0] CMD RUNTIME[0.4068s] STDOUT[ drsGlobalSystemStatus.0 = ok ] SNMP STATUS[TRUE] Store in cache Table OID: DELL-RAC-MIB::drsGlobalSystemStatus Discover status: [device: gis01-idrac, oid: .1.3.6.1.4.1.674.10892.2.2.1.0, index: 0, type: DellStatus, descr: Overall System Status, CURRENT: 3, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'DELL-RAC-MIB' AND `status_object` = 'drsGlobalSystemStatus' AND `status_type` = 'DellStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00139213s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `status_mib` = 'DELL-RAC-MIB' AND `status_object` = 'drsGlobalSystemStatus' AND `status_type` = 'DellStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00104499s] .] drsGlobalCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsGlobalCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3103s] STDOUT[ drsGlobalCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsIOMCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsIOMCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3727s] STDOUT[ drsIOMCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsKVMCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsKVMCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3565s] STDOUT[ drsKVMCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsRedCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsRedCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3873s] STDOUT[ drsRedCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsPowerCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsPowerCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3228s] STDOUT[ drsPowerCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsFanCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsFanCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.301s] STDOUT[ drsFanCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsBladeCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsBladeCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3413s] STDOUT[ drsBladeCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsTempCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsTempCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.2993s] STDOUT[ drsTempCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsCMCCurrStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsCMCCurrStatus] CMD EXITCODE[0] CMD RUNTIME[0.3291s] STDOUT[ drsCMCCurrStatus = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] drsServerMonitoringCapable [ CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsProductType.0] CMD EXITCODE[0] CMD RUNTIME[0.0955s] STDOUT[ 0 ] SNMP STATUS[TRUE] Store in cache OID: DELL-RAC-MIB::drsProductType.0 NOT TRUE Excluded by not test condition: DELL-RAC-MIB::drsProductType.0 [0] in [cmc, vrtxCMC, fx2CMC] !] o DELL-RAC-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsCMCPowerTable] CMD EXITCODE[0] CMD RUNTIME[0.3123s] STDOUT[ drsCMCPowerTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'gis01-idrac':'161' drsCMCPSUTable] CMD EXITCODE[0] CMD RUNTIME[0.3065s] STDOUT[ drsCMCPSUTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o ENTITY-SENSOR-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' entPhySensorValue] CMD EXITCODE[0] CMD RUNTIME[0.5702s] STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00164604s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00078011s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00127387s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00074196s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033092s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00045395s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00043106s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00042796s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00037694s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033998s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00032997s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033808s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00036407s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00035381s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00037694s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00037503s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029588s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029922s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029421s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029302s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029707s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00036383s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.0003109s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00089788s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00093222s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00077796s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00081801s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00032496s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00034404s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033998s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00038099s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '5' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00034499s] SQL[SELECT * FROM `status` WHERE `device_id` = '5' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00056696s] SQL[SELECT * FROM `counters` WHERE `device_id` = '5' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'] SQL RUNTIME[0.00035s] o Duration 8.9945s ##### Module Start: storage ##### o UCD-SNMP-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' dskEntry] CMD EXITCODE[0] CMD RUNTIME[0.0293s] STDOUT[ dskEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o HOST-RESOURCES-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' hrStorageEntry] CMD EXITCODE[0] CMD RUNTIME[0.0309s] STDOUT[ hrStorageEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `storage` WHERE `device_id` = '5'] SQL RUNTIME[0.00097704s] o Duration 0.0746s ##### Module Start: neighbours ##### o LLDP-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' lldpRemChassisIdSubtype] CMD EXITCODE[0] CMD RUNTIME[0.032s] STDOUT[ lldpRemChassisIdSubtype = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o CISCO-CDP-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'gis01-idrac':'161' cdpCache] CMD EXITCODE[0] CMD RUNTIME[0.6291s] STDOUT[ cdpCache = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `neighbours` WHERE `device_id` = '5'] SQL RUNTIME[0.00093389s] o Duration 0.6782s ##### Module Start: arp-table ##### o IP-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsX -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipNetToPhysicalPhysAddress] CMD EXITCODE[0] CMD RUNTIME[0.0324s] STDOUT[ ipNetToPhysicalPhysAddress[9][ipv4]["172.16.0.224"] = 5e:b4:f6:3e:7:10 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.0.253"] = 86:b0:9:17:7b:d7 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.1.10"] = b8:cb:29:bd:11:1 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.1.13"] = bc:97:e1:c8:21:81 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.1.40"] = bc:97:e1:c8:24:0 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.1.41"] = b4:96:91:40:cb:c8 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.14.3"] = a8:4a:63:7d:bf:f1 ipNetToPhysicalPhysAddress[9][ipv4]["172.16.14.30"] = 48:51:c5:4:4a:de ipNetToPhysicalPhysAddress[9][ipv4]["172.16.14.45"] = 60:5b:30:4d:dd:e2 ] SNMP STATUS[TRUE] Used IP-MIB::ipNetToPhysicalPhysAddress o IPV6-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsX -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' ipv6NetToMediaPhysAddress] CMD EXITCODE[0] CMD RUNTIME[0.7047s] STDOUT[ ipv6NetToMediaPhysAddress = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `ip_mac` WHERE `device_id` = '5'] SQL RUNTIME[0.00115395s] +---------+---------+-----+-------------+-----------------+ | ifIndex | ifDescr | VRF | IP: Version | Addresses Count | +---------+---------+-----+-------------+-----------------+ | 9 | bond0 | | IPv4 | 9 | +---------+---------+-----+-------------+-----------------+ o Changes 9 unchanged o Duration 0.7575s ##### Module Start: junose-atm-vp ##### o Duration 0.0007s ##### Module Start: bgp-peers ##### CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m BGP4-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' bgpLocalAs.0] CMD EXITCODE[0] CMD RUNTIME[0.0392s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] No BGP on host SQL[SELECT * FROM `bgpPeers` WHERE `device_id` = '5'] SQL RUNTIME[0.00097704s] o Duration 0.0476s ##### Module Start: mac-accounting ##### o Duration 0.0009s ##### Module Start: sla ##### o DISMAN-PING-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' pingCtlEntry] CMD EXITCODE[0] CMD RUNTIME[0.8386s] STDOUT[ pingCtlEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `slas` WHERE `device_id` = '5'] SQL RUNTIME[0.00109887s] o Duration 0.8479s ##### Module Start: pseudowires ##### SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '5'] SQL RUNTIME[0.00079298s] o PW-STD-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' pwID] CMD EXITCODE[0] CMD RUNTIME[0.0317s] STDOUT[ pwID = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o Duration 0.0412s ##### Module Start: cisco-cbqos ##### SQL[SELECT * FROM `ports_cbqos` WHERE `device_id` = '5'] SQL RUNTIME[0.00094199s] CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m CISCO-CLASS-BASED-QOS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'gis01-idrac':'161' cbQosIfType] CMD EXITCODE[0] CMD RUNTIME[0.7451s] STDOUT[ cbQosIfType = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] QoS not configured. o Duration 0.754s ##### Module Start: ucd-diskio ##### CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'gis01-idrac':'161' diskIOEntry] CMD EXITCODE[0] CMD RUNTIME[0.0306s] STDOUT[ diskIOEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '5'] SQL RUNTIME[0.00120711s] - SQL[DELETE FROM `ucd_diskio` WHERE `diskio_id` = ''] SQL RUNTIME[0.00054502s] o Duration 0.0409s ##### Module Start: p2p-radios ##### o Duration 0.0004s ##### Module Start: graphs ##### o Duration 0.0013s o Modules Disabled lsp, virtual-machines, wifi, raid o Modules Enabled os, mibs, vrf, ports, ports-stack, vlans, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage,neighbours, arp-table, junose-atm-vp, bgp-peers, mac-accounting, sla, pseudowires, cisco-cbqos, ucd-diskio, p2p-radios,graphs SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '5';] SQL RUNTIME[0.00034904s] SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='management',`last_discovered_timetaken` ='13.5978',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:27:{s:6:\"system\";d:0.2832;s:2:\"os\";d:0.5878;s:4:\"ipmi\";d:0.0058;s:7:\"sensors\";d:0.174;s:6:\"status\";d:0.206;s:7:\"counter\";d:0.0022;s:10:\"processors\";d:0.0034;s:8:\"mempools\";d:0.001;s:7:\"storage\";d:0.0072;s:8:\"netstats\";d:0.4654;s:7:\"ucd-mib\";d:0.0507;s:13:\"ipSystemStats\";d:0.1001;s:5:\"ports\";d:1.3453;s:9:\"bgp-peers\";d:0.0127;s:15:\"printersupplies\";d:0.0008;s:10:\"ucd-diskio\";d:0.0005;s:10:\"p2p-radios\";d:0.0014;s:4:\"ospf\";d:0.0001;s:3:\"sla\";d:0.0008;s:11:\"pseudowires\";d:0.0014;s:14:\"mac-accounting\";d:0.0014;s:12:\"loadbalancer\";d:0.0003;s:15:\"entity-physical\";d:0.0002;s:9:\"fdb-table\";d:0.0464;s:6:\"graphs\";d:0.0889;s:4:\"oids\";d:0.0691;s:6:\"probes\";d:0.0008;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.15118098258972168;s:13:\"EtherLike-MIB\";d:0.0573580265045166;s:12:\"Q-BRIDGE-MIB\";d:0.17855310440063477;s:6:\"IP-MIB\";d:0.15225601196289062;}s:14:\"poller_history\";a:288:{i:1700117498;d:3.5597;i:1700117187;d:2.5114;i:1700116886;d:2.9961;i:1700116594;d:3.344;i:1700116311;d:3.9476;i:1700115987;d:2.6451;i:1700115687;d:2.8371;i:1700115392;d:2.7473;i:1700115092;d:2.5861;i:1700114755;d:1.9012;i:1700114503;d:5.1739;i:1700114162;d:2.4869;i:1700113896;d:4.8974;i:1700113590;d:2.7882;i:1700113290;d:2.6828;i:1700112963;d:2.0148;i:1700112702;d:4.934;i:1700112384;d:2.873;i:1700112082;d:3.1449;i:1700111783;d:3.2232;i:1700111485;d:2.9789;i:1700111189;d:2.5727;i:1700110899;d:2.466;i:1700110587;d:2.4907;i:1700110285;d:2.6524;i:1700109986;d:2.5399;i:1700109692;d:2.5301;i:1700109390;d:2.4086;i:1700109048;d:2.4523;i:1700108793;d:5.5799;i:1700108487;d:2.3139;i:1700108187;d:2.7102;i:1700107876;d:2.5327;i:1700107557;d:3.3025;i:1700107302;d:5.439;i:1700106991;d:2.8611;i:1700106688;d:2.472;i:1700106388;d:2.3551;i:1700106077;d:2.7459;i:1700105769;d:3.1551;i:1700105492;d:4.7844;i:1700105192;d:3.4579;i:1700104887;d:2.6119;i:1700104559;d:2.1908;i:1700104294;d:4.5232;i:1700103930;d:1.9277;i:1700103694;d:9.2738;i:1700103393;d:2.7764;i:1700103086;d:2.3664;i:1700102787;d:2.4964;i:1700102489;d:2.4784;i:1700102177;d:2.0749;i:1700101905;d:4.0087;i:1700101569;d:2.0182;i:1700101292;d:3.9834;i:1700100986;d:2.4239;i:1700100674;d:2.5175;i:1700100385;d:3.6146;i:1700100097;d:3.7434;i:1700099758;d:2.8471;i:1700099491;d:4.6761;i:1700099185;d:2.3277;i:1700098885;d:2.6585;i:1700098588;d:2.3814;i:1700098292;d:2.4312;i:1700098005;d:2.7699;i:1700097688;d:2.2569;i:1700097377;d:2.1263;i:1700097088;d:3.5469;i:1700096754;d:2.0989;i:1700096502;d:6.0036;i:1700096187;d:2.3462;i:1700095890;d:3.0855;i:1700095588;d:2.3884;i:1700095291;d:2.2083;i:1700094986;d:2.1336;i:1700094713;d:2.7349;i:1700094385;d:2.4489;i:1700094086;d:2.5236;i:1700093791;d:2.495;i:1700093490;d:2.636;i:1700093190;d:2.3012;i:1700092827;d:2.1767;i:1700092594;d:10.3054;i:1700092294;d:3.0043;i:1700091990;d:2.7134;i:1700091687;d:2.5228;i:1700091378;d:2.4772;i:1700091094;d:3.7018;i:1700090790;d:2.6289;i:1700090485;d:2.6963;i:1700090179;d:2.8769;i:1700089882;d:3.1603;i:1700089582;d:2.9319;i:1700089314;d:3.4584;i:1700088986;d:2.3815;i:1700088688;d:2.4548;i:1700088355;d:1.9698;i:1700088071;d:4.6682;i:1700087779;d:3.6003;i:1700087499;d:3.883;i:1700087187;d:2.7376;i:1700086885;d:2.3816;i:1700086587;d:2.5141;i:1700086290;d:2.291;i:1700085943;d:1.8343;i:1700085699;d:6.6507;i:1700085385;d:2.4422;i:1700085094;d:2.5367;i:1700084792;d:2.433;i:1700084485;d:2.5606;i:1700084188;d:2.5216;i:1700083907;d:2.5076;i:1700083588;d:2.4722;i:1700083287;d:2.2387;i:1700082987;d:2.436;i:1700082688;d:2.216;i:1700082353;d:1.9896;i:1700082107;d:5.1162;i:1700081788;d:2.4968;i:1700081485;d:2.5871;i:1700081185;d:2.4849;i:1700080903;d:2.7424;i:1700080587;d:2.4151;i:1700080264;d:2.202;i:1700079992;d:4.6114;i:1700079688;d:2.4945;i:1700079389;d:2.499;i:1700079089;d:2.5087;i:1700078754;d:2.2147;i:1700078498;d:5.8821;i:1700078191;d:2.4368;i:1700077889;d:3.1865;i:1700077588;d:2.4787;i:1700077284;d:2.4027;i:1700076944;d:2.6316;i:1700076696;d:6.5189;i:1700076376;d:2.4688;i:1700076096;d:4.0738;i:1700075787;d:2.4835;i:1700075489;d:2.7448;i:1700075186;d:2.3088;i:1700074905;d:2.5483;i:1700074589;d:2.5167;i:1700074245;d:1.9066;i:1700073982;d:5.813;i:1700073684;d:3.0327;i:1700073387;d:2.5378;i:1700073076;d:2.9964;i:1700072787;d:3.8978;i:1700072488;d:2.6344;i:1700072188;d:2.5646;i:1700071889;d:2.6107;i:1700071553;d:1.9882;i:1700071300;d:5.4465;i:1700070988;d:2.2958;i:1700070697;d:3.1517;i:1700070395;d:2.591;i:1700070067;d:2.2793;i:1700069780;d:3.9298;i:1700069516;d:3.9953;i:1700069187;d:2.0774;i:1700068889;d:2.3092;i:1700068593;d:2.2465;i:1700068265;d:2.0154;i:1700067989;d:3.9691;i:1700067704;d:2.5152;i:1700067387;d:2.3873;i:1700067087;d:2.512;i:1700066772;d:2.257;i:1700066492;d:3.7426;i:1700066180;d:2.4442;i:1700065901;d:4.0194;i:1700065567;d:2.2532;i:1700065275;d:5.4405;i:1700064989;d:4.5475;i:1700064692;d:2.1791;i:1700064390;d:2.5253;i:1700064131;d:3.6919;i:1700063750;d:1.8315;i:1700063493;d:5.1322;i:1700063193;d:2.56;i:1700062896;d:2.377;i:1700062569;d:1.8146;i:1700062307;d:4.7718;i:1700061985;d:2.6317;i:1700061700;d:3.7756;i:1700061392;d:2.4222;i:1700061092;d:2.7027;i:1700060800;d:2.3062;i:1700060494;d:2.2519;i:1700060197;d:3.3938;i:1700059897;d:2.5833;i:1700059595;d:2.5457;i:1700059299;d:2.3522;i:1700058934;d:1.899;i:1700058701;d:9.2502;i:1700058396;d:2.3284;i:1700058096;d:2.3103;i:1700057807;d:2.6189;i:1700055402;d:2.2791;i:1700055113;d:2.5644;i:1700054800;d:2.292;i:1700054500;d:2.4546;i:1700054201;d:2.2866;i:1700053899;d:2.2775;i:1700053595;d:2.1388;i:1700053320;d:3.394;i:1700052999;d:2.2292;i:1700052697;d:2.3308;i:1700052400;d:2.4005;i:1700052103;d:2.154;i:1700051763;d:1.8112;i:1700051523;d:6.1293;i:1700051202;d:2.4026;i:1700050908;d:2.2812;i:1700050603;d:2.1675;i:1700050301;d:2.172;i:1700050005;d:2.0396;i:1700049722;d:2.7894;i:1700049401;d:2.229;i:1700049101;d:2.0754;i:1700048806;d:2.6784;i:1700048489;d:2.1461;i:1700048202;d:3.4011;i:1700047910;d:3.2536;i:1700047583;d:2.0068;i:1700047310;d:4.2221;i:1700046998;d:2.1873;i:1700046698;d:2.6611;i:1700046401;d:2.3603;i:1700046116;d:2.4246;i:1700045801;d:2.7112;i:1700045499;d:2.3315;i:1700045197;d:2.0909;i:1700044903;d:2.3166;i:1700044586;d:2.147;i:1700044316;d:4.5406;i:1700043998;d:2.1029;i:1700043695;d:2.041;i:1700043414;d:3.1013;i:1700043098;d:2.4542;i:1700042799;d:2.0866;i:1700042521;d:3.1358;i:1700042199;d:2.3228;i:1700041904;d:2.495;i:1700041595;d:2.6271;i:1700041302;d:2.6611;i:1700040984;d:1.999;i:1700040714;d:4.4635;i:1700040400;d:2.157;i:1700040106;d:2.4293;i:1700039797;d:2.2004;i:1700039497;d:2.2285;i:1700039191;d:2.0786;i:1700038907;d:3.0945;i:1700038597;d:2.3359;i:1700038299;d:2.0885;i:1700038002;d:2.2442;i:1700037698;d:2.0115;i:1700037402;d:2.3737;i:1700037105;d:2.422;i:1700036800;d:3.3417;i:1700036498;d:2.1699;i:1700036209;d:2.6833;i:1700035900;d:1.9919;i:1700035597;d:2.2079;i:1700035315;d:2.7002;i:1700034994;d:2.2245;i:1700034696;d:2.4588;i:1700034400;d:2.257;i:1700034087;d:2.0799;i:1700033799;d:3.0279;i:1700033510;d:2.2613;i:1700033198;d:2.0236;i:1700032894;d:2.0897;i:1700032601;d:2.6058;i:1700032288;d:2.1657;i:1700031947;d:2.8593;i:1700031698;d:5.823;i:1700031399;d:2.412;i:1700031093;d:2.1988;i:1700030792;d:2.1018;i:1700030468;d:1.9619;i:1700030189;d:4.1317;i:1700029920;d:3.316;i:1700029590;d:2.3455;i:1700029290;d:2.2668;}s:17:\"discovery_history\";a:32:{i:1700117685;d:13.5978;i:1700113856;d:13.2117;i:1700092211;d:12.7397;i:1700070515;d:13.4154;i:1700048946;d:17.4313;i:1700027200;d:12.7887;i:1700005604;d:13.3099;i:1699983951;d:13.286;i:1699962357;d:16.2511;i:1699940739;d:13.2151;i:1699919158;d:14.717;i:1699897505;d:12.5118;i:1699879524;d:12.689;i:1699870203;d:13.1705;i:1699868922;d:13.6884;i:1699857860;d:12.8429;i:1699836248;d:13.517;i:1699814686;d:14.1199;i:1699793043;d:12.3458;i:1699771474;d:13.6343;i:1699749898;d:12.9047;i:1699728291;d:12.7052;i:1699706649;d:12.2696;i:1699685089;d:14.0237;i:1699663469;d:12.5466;i:1699641808;d:12.5943;i:1699620233;d:16.1066;i:1699598632;d:13.6757;i:1699577036;d:13.154;i:1699555443;d:12.8262;i:1699533830;d:13.2561;i:1699517119;d:17.4333;}s:18:\"discovery_mod_perf\";a:26:{s:2:\"os\";d:0.0975;s:4:\"mibs\";d:0.2462;s:3:\"vrf\";d:0.0031;s:5:\"ports\";d:0.1895;s:11:\"ports-stack\";d:0.0363;s:5:\"vlans\";d:0.0471;s:11:\"ports_vlans\";N;s:4:\"oids\";d:0.0058;s:12:\"ip-addresses\";d:0.2836;s:10:\"processors\";d:0.0643;s:8:\"mempools\";d:0.0718;s:9:\"inventory\";d:0.2819;s:15:\"printersupplies\";d:0.0036;s:7:\"sensors\";d:8.9945;s:7:\"storage\";d:0.0746;s:10:\"neighbours\";d:0.6782;s:9:\"arp-table\";d:0.7575;s:13:\"junose-atm-vp\";d:0.0007;s:9:\"bgp-peers\";d:0.0476;s:14:\"mac-accounting\";d:0.0009;s:3:\"sla\";d:0.8479;s:11:\"pseudowires\";d:0.0412;s:11:\"cisco-cbqos\";d:0.754;s:10:\"ucd-diskio\";d:0.0409;s:10:\"p2p-radios\";d:0.0004;s:6:\"graphs\";d:0.0013;}}' WHERE `device_id` = '5'] SQL RUNTIME[0.00400305s] ##### gis01-idrac [5] completed discovery modules at 2023-11-16 07:54:58 ##### o Discovery time 13.5978 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '1374532' AND `process_name` = 'discovery.php' AND `device_id` = '5' AND `poller_id` = '0'] SQL RUNTIME[0.00337505s] ##### Finished discovery run at 2023-11-16 07:54:58 ##### SQL[SELECT * FROM `groups` ORDER BY `entity_type`] SQL RUNTIME[0.00043511s] SQL[SELECT * FROM `groups_assoc`] SQL RUNTIME[0.0003202s] SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'ski-skh%' AND IFNULL(`devices`.`type`, '') = 'network')] SQL RUNTIME[0.00108218s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 1] SQL RUNTIME[0.00074792s] Group 'Skillingehus': 25 existing, 25 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'ski-ffs%')] SQL RUNTIME[0.00068593s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 2] SQL RUNTIME[0.00054598s] Group 'Fågelforsskolan': 16 existing, 16 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'vgd-hjo%')] SQL RUNTIME[0.00086784s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 3] SQL RUNTIME[0.00059485s] Group 'Hjortsjöskolan': 24 existing, 24 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'vgd-fen%')] SQL RUNTIME[0.00071001s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 4] SQL RUNTIME[0.00056386s] Group 'Fenix': 16 existing, 16 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'ski-sor-%')] SQL RUNTIME[0.00052905s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 5] SQL RUNTIME[0.00046587s] Group 'Sörgården': 10 existing, 10 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'vgd-fur%')] SQL RUNTIME[0.00050879s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 6] SQL RUNTIME[0.00043893s] Group 'Furugården': 13 existing, 13 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'ski-sors%')] SQL RUNTIME[0.00050902s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 7] SQL RUNTIME[0.00040317s] Group 'Sörgårdsskolan': 5 existing, 5 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'sven%' OR IFNULL(`devices`.`hostname`, "") LIKE '%hok%')] SQL RUNTIME[0.00067997s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 8] SQL RUNTIME[0.00041604s] Group 'Hok Svenarum': 8 existing, 8 new entries (+0/-0). SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'ake%' OR IFNULL(`devices`.`hostname`, "") LIKE 'bon%')] SQL RUNTIME[0.00062895s] SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = 9] SQL RUNTIME[0.00036311s] Group 'Åker Bondstorp': 7 existing, 7 new entries (+0/-0). SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00033617s] Cached 10 alert rules. SQL[SELECT * FROM `alert_assoc`] SQL RUNTIME[0.00023103s] SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hardware`, "") NOT LIKE '%1810G%')] SQL RUNTIME[0.00102782s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 1] SQL RUNTIME[0.00158s] Alert Checker 'VK Device Down': 223 existing, 223 new entries (+0/-0). SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`sensors`.`sensor_class`, '') = 'dbm' AND IFNULL(`sensors`.`sensor_descr`, "") NOT LIKE '%Tx%') AND `sensors`.`sensor_deleted` != '1'] SQL RUNTIME[0.00314212s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 2] SQL RUNTIME[0.0006659s] Alert Checker 'VK Dålig signal på fiber': 97 existing, 97 new entries (+0/-0). SQL[SELECT `status_id`, `devices`.`device_id` as `device_id` FROM `status` LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`status`.`status_descr`, "") LIKE 'Fan') AND `status`.`status_deleted` != '1'] SQL RUNTIME[0.0028019s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 3] SQL RUNTIME[0.00081301s] Alert Checker 'VK En fläkt är trasig': 149 existing, 149 new entries (+0/-0). SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'network') AND `ports`.`deleted` != '1'] SQL RUNTIME[0.00577688s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 4] SQL RUNTIME[0.03068209s] Alert Checker 'VK Hög last på interface': 7955 existing, 7955 new entries (+0/-0). SQL[SELECT `mempool_id`, `devices`.`device_id` as `device_id` FROM `mempools` LEFT JOIN `devices` ON (`mempools`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'network') AND `mempools`.`mempool_deleted` != '1'] SQL RUNTIME[0.00143194s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 5] SQL RUNTIME[0.00110793s] Alert Checker 'VK Minnesproblem': 170 existing, 170 new entries (+0/-0). SQL[SELECT `status_id`, `devices`.`device_id` as `device_id` FROM `status` LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`status`.`status_descr`, "") LIKE '%ower%' OR IFNULL(`status`.`status_descr`, "") LIKE '%ps2%' OR IFNULL(`status`.`status_descr`, "") LIKE '%ps1%') AND `status`.`status_deleted` != '1'] SQL RUNTIME[0.00525308s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 6] SQL RUNTIME[0.00046301s] Alert Checker 'VK Ett Powersupply har problem': 44 existing, 44 new entries (+0/-0). SQL[SELECT `storage_id`, `devices`.`device_id` as `device_id` FROM `storage` LEFT JOIN `devices` ON (`storage`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'server') AND `storage`.`storage_deleted` != '1'] SQL RUNTIME[0.0003171s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 7] SQL RUNTIME[0.00023794s] Alert Checker 'VK Server har ont om disk': 16 existing, 16 new entries (+0/-0). SQL[SELECT `processor_id`, `devices`.`device_id` as `device_id` FROM `processors` LEFT JOIN `devices` ON (`processors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'network')] SQL RUNTIME[0.00080895s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 8] SQL RUNTIME[0.00073004s] Alert Checker 'VK Switch CPU': 176 existing, 176 new entries (+0/-0). SQL[SELECT `probe_id`, `devices`.`device_id` as `device_id` FROM `probes` LEFT JOIN `devices` ON (`probes`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`probes`.`probe_descr`, "") LIKE '%Cert%')] SQL RUNTIME[0.00026703s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 10] SQL RUNTIME[0.00021791s] Alert Checker 'VK Certifikat har gått ut': 7 existing, 7 new entries (+0/-0). SQL[SELECT `probe_id`, `devices`.`device_id` as `device_id` FROM `probes` LEFT JOIN `devices` ON (`probes`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`probes`.`probe_descr`, "") LIKE '%Cert%')] SQL RUNTIME[0.00024486s] SQL[SELECT `alert_table_id`, `entity_id`, `device_id` FROM `alert_table` WHERE `alert_test_id` = 11] SQL RUNTIME[0.00025487s] Alert Checker 'VK Ett certifikat håller på att gå ut': 7 existing, 7 new entries (+0/-0). ./discovery.php: gis01-idrac - 1 devices discovered in 13.8095 secs SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1700103298'] SQL RUNTIME[0.00023293s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Discovered 1 o Discovery Time 13.8095 secs o Definitions 0.1315770149231 secs o Memory usage 38MB (peak: 38MB) o MySQL Usage Cell[72/0.144s] Row[115/0.173s] Rows[112/0.25s] Column[11/0.014s] Update[1/0.005s] Insert[1/0.005s] Delete[3/0.012s] o RRDTool Usage root@observium:/opt/observium#