DEBUG!
DEFINITIONS loaded by: 0.0601370 ms

DEFINITIONS in memory: 17.1MB


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00066113s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00030613s]

SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00015783s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00023985s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00037193s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00035310s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'cache_cli_clear';]
SQL RUNTIME[0.00031209s]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                    Observium Community Edition 22.12.12447
                                  https://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.1159s]
STDOUT[
Linux|4.15.0-200-generic|amd64|Ubuntu|18.04|kvm|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0037s]
STDOUT[
Python 2.7.17
]

SQL[SELECT version();]
SQL RUNTIME[0.00031495s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.003s]
STDOUT[
NET-SNMP version: 5.7.3
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0144s]
STDOUT[
RRDtool 1.7.0  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0023s]
STDOUT[
/usr/bin/fping: Version 4.0
/usr/bin/fping: comments to david@schweikert.ch
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0447s]
STDOUT[
Apache/2.4.29
]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00033784s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.08526802s]

#####  Software versions  #####

 o OS                   Linux 4.15.0-200-generic [amd64] (Ubuntu 18.04)
 o Apache               2.4.29
 o PHP                  7.2.24-0ubuntu0.18.04.17 (OPcache: DISABLED)
 o Python               2.7.17
 o MySQL                5.7.41-0ubuntu0.18.04.1 (extension: mysqli 5.0.12-dev)
 o SNMP                 NET-SNMP 5.7.3
 o RRDtool              1.7.0
 o Fping                4.0 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  Unlimited

#####  DB info  #####

 o DB schema            477
 o MySQL mode           NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8

#####  Timezones info  #####

 o Date                 Tuesday, 25-Apr-23 10:16:24 EDT
 o PHP                  -04:00
 o MySQL                -04:00

#####  Fast Cache info  #####

 o Enabled              Yes
 o Driver               Files
 o Total size           183B


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00028300s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'http_rate_https://www.observium.org';]
SQL RUNTIME[0.00026393s]

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'http_rate_https://www.observium.org')]
SQL RUNTIME[0.00027418s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='{\"2023-04-25\":3}' WHERE `attrib_type` = 'http_rate_https://www.observium.org']
SQL RUNTIME[0.00593114s]
HTTP CURL cmd:
curl --connect-timeout 15 -X POST -H 'Connection: close' -H 'Content-Type: application/x-www-form-urlencoded; charset=utf-8' -H 'Content-Length: 58' -H 'User-Agent: Observium CE/22.12.12447' -d 'stats=YToxOntzOjc6InZlcnNpb24iO3M6MTE6IjIyLjEyLjEyNDQ3Ijt9' https://www.observium.org/versions.php

REQUEST[https://www.observium.org/versions.php]
REQUEST STATUS[TRUE]
REQUEST RUNTIME[0.4245s]
RESPONSE CODE[200 OK]
Response [12651] valid: [stable->revision] regex [^\d+$]


  /opt/observium/includes/common.inc.php:4151
array(
  [stable]  => array(
                 [version]  => string(10) "23.4.12651"
                 [revision] => string(5) "12651"
                 [date]     => string(10) "2023-04-13"
               )
  [current] => array(
                 [version]  => string(10) "23.4.12743"
                 [revision] => string(5) "12743"
                 [date]     => string(10) "2023-04-25"
               )
  [ce]      => array(
                 [version]  => string(5) "22.12"
                 [revision] => string(5) "12447"
                 [date]     => string(10) "2022-12-30"
               )
)

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver')]
SQL RUNTIME[0.00036001s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='22.12' WHERE `attrib_type` = 'latest_ver']
SQL RUNTIME[0.00400400s]

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev')]
SQL RUNTIME[0.00029612s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='12447' WHERE `attrib_type` = 'latest_rev']
SQL RUNTIME[0.77269483s]

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date')]
SQL RUNTIME[0.00059700s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='2022-12-30' WHERE `attrib_type` = 'latest_rev_date']
SQL RUNTIME[0.62543702s]

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck')]
SQL RUNTIME[0.00025105s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='1682432186' WHERE `attrib_type` = 'last_versioncheck']
SQL RUNTIME[0.00391388s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00029302s]
#####  Starting discovery run at 2023-04-25 10:16:26  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00115895s]

CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0233s]
STDOUT[
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.13742.6
.1.3.6.1.2.1.1.3.0 = 48:22:09:54.35
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '153']
SQL RUNTIME[0.00071216s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '153' AND `poller_id` = '0']
SQL RUNTIME[0.00034404s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('9236','discovery.php','7716','0','php ./discovery.php -h pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net -d','1682432186','153')]
SQL RUNTIME[0.09193087s]
#####  pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net [153]  #####

 o OS Type              raritan
 o OS Group             pdu
 o SNMP Version         v2c
 o Last discovery       2023-04-25 06:36:55
 o Last duration        5.03 seconds

#####  Module Start: os  #####


CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0263s]
STDOUT[
PX2 030660
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.026s]
STDOUT[
.1.3.6.1.4.1.13742.6
]
SNMP STATUS[TRUE]
+-------------+----------------------+
| OID         |                      |
+-------------+----------------------+
| sysDescr    | PX2 030660           |
| sysObjectID | .1.3.6.1.4.1.13742.6 |
+-------------+----------------------+

 o Detect OS matched (raritan: Raritan PDU):
+-------------+--------------------+----------------------+
| OID         | Matched definition |                      |
+-------------+--------------------+----------------------+
| sysObjectID | .1.3.6.1.4.1.13742 | .1.3.6.1.4.1.13742.6 |
+-------------+--------------------+----------------------+


 o Duration             0.1447s

#####  Module Start: mibs  #####


CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']

CMD EXITCODE[0]
CMD RUNTIME[0.0166s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2'

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' .1.3.6.1.2.1.1.9.1.2]

CMD EXITCODE[0]
CMD RUNTIME[0.0265s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1
.1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.16.2.2.1
.1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.2.1.49
.1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.2.1.4
.1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.2.1.50
.1.3.6.1.2.1.1.9.1.2.6 = .1.3.6.1.6.3.10.3.1.1
.1.3.6.1.2.1.1.9.1.2.7 = .1.3.6.1.6.3.11.3.1.1
.1.3.6.1.2.1.1.9.1.2.8 = .1.3.6.1.6.3.15.2.1.1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' sysORDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0261s]
STDOUT[
sysORDescr.1 = The MIB module for SNMPv2 entities
sysORDescr.2 = View-based Access Control Model for SNMP.
sysORDescr.3 = The MIB module for managing TCP implementations
sysORDescr.4 = The MIB module for managing IP and ICMP implementations
sysORDescr.5 = The MIB module for managing UDP implementations
sysORDescr.6 = The SNMP Management Architecture MIB.
sysORDescr.7 = The MIB for Message Processing and Dispatching.
sysORDescr.8 = The management information definitions for the SNMP User-based Security Model.
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m OSPFV3-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ospfv3AdminStatus.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0381s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
Store in cache OID: OSPFV3-MIB::ospfv3AdminStatus.0
 o MIBs discovered      TCP-MIB UDP-MIB
+-----------------------+--------------------+---------+---------------------+
| Identity              | MIB                | Source  | Status              |
+-----------------------+--------------------+---------+---------------------+
| .1.3.6.1.6.3.1        | SNMPv2-MIB         | sysORID | MIB already defined |
| .1.3.6.1.2.1.4        | IP-MIB             | sysORID | MIB already defined |
| .1.3.6.1.2.1.49       | TCP-MIB            | sysORID | MIB added           |
| .1.3.6.1.2.1.50       | UDP-MIB            | sysORID | MIB added           |
| .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined |
| .1.3.6.1.4.1.13742.6  | PDU2-MIB           | Model   | MIB already defined |
| .1.3.6.1.6.3.16.2.2.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.11.3.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.15.2.1.1 | -                  | sysORID | Unknown Identity    |
+-----------------------+--------------------+---------+---------------------+


SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '153' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00067997s]


  /opt/observium/includes/discovery/mibs.inc.php:313
array(
  [0]  => string(8) "PDU2-MIB"
  [1]  => string(7) "TCP-MIB"
  [2]  => string(7) "UDP-MIB"
  [3]  => string(10) "SNMPv2-MIB"
  [4]  => string(18) "SNMP-FRAMEWORK-MIB"
  [5]  => string(6) "IF-MIB"
  [6]  => string(13) "ADSL-LINE-MIB"
  [7]  => string(13) "EtherLike-MIB"
  [8]  => string(10) "ENTITY-MIB"
  [9]  => string(17) "ENTITY-SENSOR-MIB"
  [10] => string(12) "UCD-SNMP-MIB"
  [11] => string(18) "HOST-RESOURCES-MIB"
  [12] => string(12) "Q-BRIDGE-MIB"
  [13] => string(6) "IP-MIB"
  [14] => string(8) "IPV6-MIB"
  [15] => string(8) "LLDP-MIB"
  [16] => string(13) "CISCO-CDP-MIB"
  [17] => string(15) "DISMAN-PING-MIB"
)

 o Duration             0.1422s

Module [vrf] blacklisted by os definition in process [discovery].
#####  Module Start: ports  #####

 o Caching OIDs         ifDescr
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ifDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0262s]
STDOUT[
ifDescr.1 = lo
ifDescr.2 = eth0
]
SNMP STATUS[TRUE]
ifAlias
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ifAlias]

CMD EXITCODE[0]
CMD RUNTIME[0.0462s]
STDOUT[
ifAlias.1 =
ifAlias.2 =
]
SNMP STATUS[TRUE]
ifName
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ifName]

CMD EXITCODE[0]
CMD RUNTIME[0.0263s]
STDOUT[
ifName.1 = lo
ifName.2 = eth0
]
SNMP STATUS[TRUE]
ifType
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ifType]

CMD EXITCODE[0]
CMD RUNTIME[0.0293s]
STDOUT[
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd
]
SNMP STATUS[TRUE]
ifOperStatus
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ifOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0274s]
STDOUT[
ifOperStatus.1 = up
ifOperStatus.2 = up
]
SNMP STATUS[TRUE]



  /opt/observium/includes/discovery/ports.inc.php:44
array(
  [1] => array(
           [ifDescr]      => string(2) "lo"
           [ifAlias]      => string(0) ""
           [ifName]       => string(2) "lo"
           [ifType]       => string(16) "softwareLoopback"
           [ifOperStatus] => string(2) "up"
         )
  [2] => array(
           [ifDescr]      => string(4) "eth0"
           [ifAlias]      => string(0) ""
           [ifName]       => string(4) "eth0"
           [ifType]       => string(14) "ethernetCsmacd"
           [ifOperStatus] => string(2) "up"
         )
)
 o Caching DB
SQL[SELECT * FROM `ports` WHERE `device_id` = '153']
SQL RUNTIME[0.00072598s]
2 ports
 o Discovering ports    ..
+---------+---------+--------+---------+------------------+-------------+---------+
| ifIndex | ifDescr | ifName | ifAlias | ifType           | Oper Status | Ignored |
+---------+---------+--------+---------+------------------+-------------+---------+
| 1       | lo      | lo     | ...     | softwareLoopback | up          | no      |
| 2       | eth0    | eth0   | ...     | ethernetCsmacd   | up          | no      |
+---------+---------+--------+---------+------------------+-------------+---------+


 o Duration             0.1729s

Module [ports-stack] disabled by os definition in process [discovery].
Module [vlans] disabled by os definition in process [discovery].
#####  Module Start: oids  #####


SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '153']
SQL RUNTIME[0.00046682s]

SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1']
SQL RUNTIME[0.00031090s]

 o Duration             0.0023s

#####  Module Start: ip-addresses  #####

 o IP-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAdEntIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0333s]
STDOUT[
ipAdEntIfIndex.127.0.0.1 = 1
ipAdEntIfIndex.172.29.41.35 = 2
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAdEntNetMask]

CMD EXITCODE[0]
CMD RUNTIME[0.0309s]
STDOUT[
ipAdEntNetMask.127.0.0.1 = 255.0.0.0
ipAdEntNetMask.172.29.41.35 = 255.255.255.192
]
SNMP STATUS[TRUE]
Added 127.0.0.1
.Added 172.29.41.35
.
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAddressIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0322s]
STDOUT[
ipAddressIfIndex.ipv4."127.0.0.1" = 1
ipAddressIfIndex.ipv4."172.29.41.35" = 2
ipAddressIfIndex.ipv4."172.29.41.63" = 2
ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = 1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAddressType]

CMD EXITCODE[0]
CMD RUNTIME[0.0399s]
STDOUT[
ipAddressType.ipv4."127.0.0.1" = unicast
ipAddressType.ipv4."172.29.41.35" = unicast
ipAddressType.ipv4."172.29.41.63" = broadcast
ipAddressType.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = unicast
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAddressPrefix]

CMD EXITCODE[0]
CMD RUNTIME[0.0288s]
STDOUT[
ipAddressPrefix.ipv4."127.0.0.1" = ipAddressPrefixOrigin.1.ipv4."127.0.0.0".8
ipAddressPrefix.ipv4."172.29.41.35" = ipAddressPrefixOrigin.2.ipv4."172.29.41.0".26
ipAddressPrefix.ipv4."172.29.41.63" = ipAddressPrefixOrigin.2.ipv4."172.29.41.0".26
ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipAddressOrigin]

CMD EXITCODE[0]
CMD RUNTIME[0.0313s]
STDOUT[
ipAddressOrigin.ipv4."127.0.0.1" = manual
ipAddressOrigin.ipv4."172.29.41.35" = dhcp
ipAddressOrigin.ipv4."172.29.41.63" = dhcp
ipAddressOrigin.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = manual
]
SNMP STATUS[TRUE]
Added 0000:0000:0000:0000:0000:0000:0000:0001
.
 o IPV6-MIB
 o LLDP-MIB

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '153']
SQL RUNTIME[0.00054884s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '153' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00025988s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '25501']
SQL RUNTIME[0.00034904s]

SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '153']
SQL RUNTIME[0.00038981s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '25501']
SQL RUNTIME[0.00032902s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '153']
SQL RUNTIME[0.00043082s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '153']
SQL RUNTIME[0.00043011s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
SQL RUNTIME[0.00033903s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '153' AND `ifIndex` = '2' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00022602s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '25502']
SQL RUNTIME[0.00028801s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '25502']
SQL RUNTIME[0.00031996s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.29.41.0/26']
SQL RUNTIME[0.00029397s]

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '153']
SQL RUNTIME[0.00023603s]

SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '153']
SQL RUNTIME[0.00035214s]

SQL[SELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128']
SQL RUNTIME[0.00031590s]

SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '153']
SQL RUNTIME[0.00025392s]
+---------+---------+-------------+-----------------+---------------------+----------+--------+
| ifIndex | ifDescr | IP: Version | Address         | Network             | Type     | Origin |
+---------+---------+-------------+-----------------+---------------------+----------+--------+
| 1       | lo      | IPv4        | 127.0.0.1/8     | 127.0.0.0/8         | loopback |        |
| 2       | eth0    | IPv4        | 172.29.41.35/26 | 172.29.41.0/26      | private  |        |
| 1       | lo      | IPv6        | ::1/128         | 0:0:0:0:0:0:0:1/128 | loopback | manual |
+---------+---------+-------------+-----------------+---------------------+----------+--------+


 o Changes              3 unchanged
 o Duration             0.2364s

#####  Module Start: processors  #####

 o UCD-SNMP-MIB
SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '153' AND `processor_type` != 'ucd-old')]
SQL RUNTIME[0.00042009s]

 o HOST-RESOURCES-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrProcessorLoad]

CMD EXITCODE[0]
CMD RUNTIME[0.0321s]
STDOUT[
hrProcessorLoad.196608 = 6
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrDevice]

CMD EXITCODE[0]
CMD RUNTIME[0.0285s]
STDOUT[
hrProcessorFrwID.196608 = zeroDotZero
hrProcessorLoad.196608 = 6
]
SNMP STATUS[TRUE]
153 -> .1.3.6.1.2.1.25.3.3.1.2.196608, 196608, hr, Processor, 1, 6, , 196608

SQL[SELECT * FROM `processors` WHERE `device_id` = '153' AND `processor_index` = '196608' AND `processor_type` = 'hr']
SQL RUNTIME[0.00070286s]
153 -> 1, 1, hr-average, Average, 1, 6, ,

SQL[SELECT * FROM `processors` WHERE `device_id` = '153' AND `processor_index` = '1' AND `processor_type` = 'hr-average']
SQL RUNTIME[0.00035000s]

SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '153' AND `processor_type` = 'ucd-old')]
SQL RUNTIME[0.00026417s]


SQL[SELECT * FROM `processors` WHERE `device_id` = '153']
SQL RUNTIME[0.00029707s]
196608 -> hr
1 -> hr-average


 > $valid['processor'] /opt/observium/includes/discovery/processors.inc.php:165
array(
  [hr]         => array(
                    [196608] => int(1)
                  )
  [hr-average] => array(
                    [1] => int(1)
                  )
)

 o Changes              2 unchanged
 o Duration             0.0741s

#####  Module Start: mempools  #####

 o UCD-SNMP-MIB
CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0243s]
STDOUT[
memTotalReal.0 = No Such Object available on this agent at this OID
memAvailReal.0 = No Such Object available on this agent at this OID
memBuffer.0 = No Such Object available on this agent at this OID
memCached.0 = No Such Object available on this agent at this OID
]
SNMP ERROR[#1000 - Failed response]
SNMP STATUS[FALSE]

 o HOST-RESOURCES-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0296s]
STDOUT[
hrStorageEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `mempools` WHERE `device_id` = '153']
SQL RUNTIME[0.00047588s]

 o Duration             0.0617s

#####  Module Start: inventory  #####

 o ENTITY-MIB           ENTITY-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' entPhysicalEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.141s]
STDOUT[
entPhysicalEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrDeviceEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0322s]
STDOUT[
hrDeviceEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrProcessorEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0272s]
STDOUT[
hrProcessorFrwID.196608 = zeroDotZero
hrProcessorLoad.196608 = 6
]
SNMP STATUS[TRUE]
Empty hrDevice entry skipped:


  /opt/observium/includes/discovery/inventory/host-resources-mib.inc.php:25
array(
  [hrProcessorFrwID] => string(11) "zeroDotZero"
  [hrProcessorLoad]  => string(1) "6"
)

SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '153']
SQL RUNTIME[0.00072885s]


SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '153']
SQL RUNTIME[0.00041795s]

 o Duration             0.2114s

#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '153']
SQL RUNTIME[0.00034595s]


 o Duration             0.0018s

#####  Module Start: sensors  #####

 o PDU2-MIB              PDU2-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletName]

CMD EXITCODE[0]
CMD RUNTIME[0.0988s]
STDOUT[
inletName.1.1 =
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorUnits]

CMD EXITCODE[0]
CMD RUNTIME[0.044s]
STDOUT[
inletSensorUnits.1.1.rmsCurrent = amp
inletSensorUnits.1.1.unbalancedCurrent = percent
inletSensorUnits.1.1.rmsVoltage = volt
inletSensorUnits.1.1.activePower = watt
inletSensorUnits.1.1.apparentPower = voltamp
inletSensorUnits.1.1.powerFactor = none
inletSensorUnits.1.1.activeEnergy = wattHour
inletSensorUnits.1.1.frequency = hertz
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorDecimalDigits]

CMD EXITCODE[0]
CMD RUNTIME[0.033s]
STDOUT[
inletSensorDecimalDigits.1.1.rmsCurrent = 3
inletSensorDecimalDigits.1.1.unbalancedCurrent = 0
inletSensorDecimalDigits.1.1.rmsVoltage = 0
inletSensorDecimalDigits.1.1.activePower = 0
inletSensorDecimalDigits.1.1.apparentPower = 0
inletSensorDecimalDigits.1.1.powerFactor = 2
inletSensorDecimalDigits.1.1.activeEnergy = 0
inletSensorDecimalDigits.1.1.frequency = 1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorEnabledThresholds]

CMD EXITCODE[0]
CMD RUNTIME[0.0398s]
STDOUT[
inletSensorEnabledThresholds.1.1.rmsCurrent = "00 "
inletSensorEnabledThresholds.1.1.unbalancedCurrent = "00 "
inletSensorEnabledThresholds.1.1.rmsVoltage = "00 "
inletSensorEnabledThresholds.1.1.activePower = "00 "
inletSensorEnabledThresholds.1.1.apparentPower = "00 "
inletSensorEnabledThresholds.1.1.powerFactor = "00 "
inletSensorEnabledThresholds.1.1.activeEnergy = "00 "
inletSensorEnabledThresholds.1.1.frequency = "00 "
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0379s]
STDOUT[
inletSensorLowerCriticalThreshold.1.1.rmsCurrent = 0
inletSensorLowerCriticalThreshold.1.1.unbalancedCurrent = 0
inletSensorLowerCriticalThreshold.1.1.rmsVoltage = 0
inletSensorLowerCriticalThreshold.1.1.activePower = 0
inletSensorLowerCriticalThreshold.1.1.apparentPower = 0
inletSensorLowerCriticalThreshold.1.1.powerFactor = 0
inletSensorLowerCriticalThreshold.1.1.activeEnergy = 0
inletSensorLowerCriticalThreshold.1.1.frequency = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorLowerWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.044s]
STDOUT[
inletSensorLowerWarningThreshold.1.1.rmsCurrent = 0
inletSensorLowerWarningThreshold.1.1.unbalancedCurrent = 0
inletSensorLowerWarningThreshold.1.1.rmsVoltage = 0
inletSensorLowerWarningThreshold.1.1.activePower = 0
inletSensorLowerWarningThreshold.1.1.apparentPower = 0
inletSensorLowerWarningThreshold.1.1.powerFactor = 0
inletSensorLowerWarningThreshold.1.1.activeEnergy = 0
inletSensorLowerWarningThreshold.1.1.frequency = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorUpperWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0385s]
STDOUT[
inletSensorUpperWarningThreshold.1.1.rmsCurrent = 0
inletSensorUpperWarningThreshold.1.1.unbalancedCurrent = 5
inletSensorUpperWarningThreshold.1.1.rmsVoltage = 0
inletSensorUpperWarningThreshold.1.1.activePower = 0
inletSensorUpperWarningThreshold.1.1.apparentPower = 0
inletSensorUpperWarningThreshold.1.1.powerFactor = 0
inletSensorUpperWarningThreshold.1.1.activeEnergy = 0
inletSensorUpperWarningThreshold.1.1.frequency = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' inletSensorUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.042s]
STDOUT[
inletSensorUpperCriticalThreshold.1.1.rmsCurrent = 0
inletSensorUpperCriticalThreshold.1.1.unbalancedCurrent = 10
inletSensorUpperCriticalThreshold.1.1.rmsVoltage = 0
inletSensorUpperCriticalThreshold.1.1.activePower = 0
inletSensorUpperCriticalThreshold.1.1.apparentPower = 0
inletSensorUpperCriticalThreshold.1.1.powerFactor = 0
inletSensorUpperCriticalThreshold.1.1.activeEnergy = 0
inletSensorUpperCriticalThreshold.1.1.frequency = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsInletSensorIsAvailable]

CMD EXITCODE[0]
CMD RUNTIME[0.0393s]
STDOUT[
measurementsInletSensorIsAvailable.1.1.rmsCurrent = true
measurementsInletSensorIsAvailable.1.1.unbalancedCurrent = true
measurementsInletSensorIsAvailable.1.1.rmsVoltage = true
measurementsInletSensorIsAvailable.1.1.activePower = true
measurementsInletSensorIsAvailable.1.1.apparentPower = true
measurementsInletSensorIsAvailable.1.1.powerFactor = true
measurementsInletSensorIsAvailable.1.1.activeEnergy = true
measurementsInletSensorIsAvailable.1.1.frequency = true
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsInletSensorState]

CMD EXITCODE[0]
CMD RUNTIME[0.038s]
STDOUT[
measurementsInletSensorState.1.1.rmsCurrent = normal
measurementsInletSensorState.1.1.unbalancedCurrent = normal
measurementsInletSensorState.1.1.rmsVoltage = normal
measurementsInletSensorState.1.1.activePower = normal
measurementsInletSensorState.1.1.apparentPower = normal
measurementsInletSensorState.1.1.powerFactor = normal
measurementsInletSensorState.1.1.activeEnergy = normal
measurementsInletSensorState.1.1.frequency = normal
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsInletSensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0423s]
STDOUT[
measurementsInletSensorValue.1.1.rmsCurrent = 3871
measurementsInletSensorValue.1.1.unbalancedCurrent = 153
measurementsInletSensorValue.1.1.rmsVoltage = 416
measurementsInletSensorValue.1.1.activePower = 987
measurementsInletSensorValue.1.1.apparentPower = 1102
measurementsInletSensorValue.1.1.powerFactor = 90
measurementsInletSensorValue.1.1.activeEnergy = 5609140
measurementsInletSensorValue.1.1.frequency = 600
]
SNMP STATUS[TRUE]
Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.1, index: 1.1.1, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 0.001, limits: (, , , ), CURRENT: 3.871, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.1')]
SQL RUNTIME[0.00099301s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.1']
SQL RUNTIME[0.00068307s]
LCurrent sensor value: "3.871", scale: "0.001"
  limit_high: "5.664" -> "5.8065"
  limit_high_warn: "" -> ""
  limit_low: "" -> ""
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='5.8065' WHERE `sensor_id` = '4960']
SQL RUNTIME[0.02189398s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4960' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00038099s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4960' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00029993s]
.Discover sensor: [class: humidity, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.3, index: 1.1.3, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 1, limits: (, , , ), CURRENT: 153, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'humidity' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.3')]
SQL RUNTIME[0.00054002s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'humidity' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.3']
SQL RUNTIME[0.00059104s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4961' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024796s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4961' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00027180s]
.Discover sensor: [class: voltage, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.4, index: 1.1.4, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 1, limits: (, , , ), CURRENT: 416, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.4')]
SQL RUNTIME[0.00059700s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.4']
SQL RUNTIME[0.00060201s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4962' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027394s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4962' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00025892s]
.Discover sensor: [class: power, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.5, index: 1.1.5, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 1, limits: (, , , ), CURRENT: 987, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.5')]
SQL RUNTIME[0.00052905s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.5']
SQL RUNTIME[0.00060582s]
LCurrent sensor value: "987", scale: "1"
  limit_high: "1441.5" -> "1480.5"
  limit_high_warn: "" -> ""
  limit_low: "" -> ""
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='1480.5' WHERE `sensor_id` = '4963']
SQL RUNTIME[0.00370598s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4963' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00032306s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4963' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00030494s]
.Discover sensor: [class: apower, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.6, index: 1.1.6, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 1, limits: (, , , ), CURRENT: 1102, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'apower' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.6')]
SQL RUNTIME[0.00046396s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'apower' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.6']
SQL RUNTIME[0.00047112s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4964' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00029802s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4964' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00025678s]
.Discover sensor: [class: powerfactor, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.7, index: 1.1.7, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 0.01, limits: (, , , ), CURRENT: 0.9, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'powerfactor' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.7')]
SQL RUNTIME[0.00044084s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'powerfactor' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.7']
SQL RUNTIME[0.00042582s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4965' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028110s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4965' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023508s]
.Discover counter: [class: energy, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.8, index: 1.1.8, descr: Inlet 1.1, scale: 1, limits: (, , , ), CURRENT: 5609140, ,

SQL[SELECT EXISTS (SELECT 1 FROM `counters` WHERE `device_id` = '153' AND `counter_class` = 'energy' AND `counter_mib` = 'PDU2-MIB' AND `counter_object` = 'measurementsInletSensorValue' AND `counter_index` = '1.1.8' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00041199s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '153' AND `counter_class` = 'energy' AND `counter_mib` = 'PDU2-MIB' AND `counter_object` = 'measurementsInletSensorValue' AND `counter_index` = '1.1.8' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00045800s]
.Discover sensor: [class: frequency, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.2.3.1.4.1.1.23, index: 1.1.23, type: PDU2-MIB-measurementsInletSensorValue, descr: Inlet 1.1, scale: 0.1, limits: (, , , ), CURRENT: 60, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.23')]
SQL RUNTIME[0.00046301s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsInletSensorValue' AND `sensor_index` = '1.1.23']
SQL RUNTIME[0.00047708s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4966' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027800s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4966' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023603s]
.
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletName]

CMD EXITCODE[0]
CMD RUNTIME[0.3448s]
STDOUT[
outletName.1.1 =
outletName.1.2 =
outletName.1.3 =
outletName.1.4 =
outletName.1.5 =
outletName.1.6 =
outletName.1.7 =
outletName.1.8 =
outletName.1.9 =
outletName.1.10 =
outletName.1.11 =
outletName.1.12 =
outletName.1.13 =
outletName.1.14 =
outletName.1.15 =
outletName.1.16 =
outletName.1.17 =
outletName.1.18 =
outletName.1.19 =
outletName.1.20 =
outletName.1.21 =
outletName.1.22 =
outletName.1.23 =
outletName.1.24 =
outletName.1.25 =
outletName.1.26 =
outletName.1.27 =
outletName.1.28 =
outletName.1.29 =
outletName.1.30 =
outletName.1.31 =
outletName.1.32 =
outletName.1.33 =
outletName.1.34 =
outletName.1.35 =
outletName.1.36 =
outletName.1.37 =
outletName.1.38 =
outletName.1.39 =
outletName.1.40 =
outletName.1.41 =
outletName.1.42 =
outletName.1.43 =
outletName.1.44 =
outletName.1.45 =
outletName.1.46 =
outletName.1.47 =
outletName.1.48 =
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorUnits]

CMD EXITCODE[0]
CMD RUNTIME[0.0865s]
STDOUT[
outletSensorUnits = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorDecimalDigits]

CMD EXITCODE[0]
CMD RUNTIME[0.0809s]
STDOUT[
outletSensorDecimalDigits = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorEnabledThresholds]

CMD EXITCODE[0]
CMD RUNTIME[0.0526s]
STDOUT[
outletSensorEnabledThresholds = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0663s]
STDOUT[
outletSensorLowerCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorLowerWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0577s]
STDOUT[
outletSensorLowerWarningThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorUpperWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0667s]
STDOUT[
outletSensorUpperWarningThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' outletSensorUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0678s]
STDOUT[
outletSensorUpperCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOutletSensorIsAvailable]

CMD EXITCODE[0]
CMD RUNTIME[0.106s]
STDOUT[
measurementsOutletSensorIsAvailable = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOutletSensorState]

CMD EXITCODE[0]
CMD RUNTIME[0.1065s]
STDOUT[
measurementsOutletSensorState = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOutletSensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.1029s]
STDOUT[
measurementsOutletSensorValue = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorName]

CMD EXITCODE[0]
CMD RUNTIME[0.0574s]
STDOUT[
overCurrentProtectorName.1.1 =
overCurrentProtectorName.1.2 =
overCurrentProtectorName.1.3 =
overCurrentProtectorName.1.4 =
overCurrentProtectorName.1.5 =
overCurrentProtectorName.1.6 =
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorUnits]

CMD EXITCODE[0]
CMD RUNTIME[0.0391s]
STDOUT[
overCurrentProtectorSensorUnits.1.1.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.1.trip = none
overCurrentProtectorSensorUnits.1.2.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.2.trip = none
overCurrentProtectorSensorUnits.1.3.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.3.trip = none
overCurrentProtectorSensorUnits.1.4.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.4.trip = none
overCurrentProtectorSensorUnits.1.5.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.5.trip = none
overCurrentProtectorSensorUnits.1.6.rmsCurrent = amp
overCurrentProtectorSensorUnits.1.6.trip = none
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorDecimalDigits]

CMD EXITCODE[0]
CMD RUNTIME[0.0403s]
STDOUT[
overCurrentProtectorSensorDecimalDigits.1.1.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.1.trip = 0
overCurrentProtectorSensorDecimalDigits.1.2.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.2.trip = 0
overCurrentProtectorSensorDecimalDigits.1.3.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.3.trip = 0
overCurrentProtectorSensorDecimalDigits.1.4.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.4.trip = 0
overCurrentProtectorSensorDecimalDigits.1.5.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.5.trip = 0
overCurrentProtectorSensorDecimalDigits.1.6.rmsCurrent = 1
overCurrentProtectorSensorDecimalDigits.1.6.trip = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorEnabledThresholds]

CMD EXITCODE[0]
CMD RUNTIME[0.0419s]
STDOUT[
overCurrentProtectorSensorEnabledThresholds.1.1.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.1.trip = "00 "
overCurrentProtectorSensorEnabledThresholds.1.2.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.2.trip = "00 "
overCurrentProtectorSensorEnabledThresholds.1.3.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.3.trip = "00 "
overCurrentProtectorSensorEnabledThresholds.1.4.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.4.trip = "00 "
overCurrentProtectorSensorEnabledThresholds.1.5.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.5.trip = "00 "
overCurrentProtectorSensorEnabledThresholds.1.6.rmsCurrent = "30 "
overCurrentProtectorSensorEnabledThresholds.1.6.trip = "00 "
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0465s]
STDOUT[
overCurrentProtectorSensorLowerCriticalThreshold.1.1.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.1.trip = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.2.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.2.trip = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.3.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.3.trip = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.4.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.4.trip = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.5.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.5.trip = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.6.rmsCurrent = 0
overCurrentProtectorSensorLowerCriticalThreshold.1.6.trip = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorLowerWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0423s]
STDOUT[
overCurrentProtectorSensorLowerWarningThreshold.1.1.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.1.trip = 0
overCurrentProtectorSensorLowerWarningThreshold.1.2.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.2.trip = 0
overCurrentProtectorSensorLowerWarningThreshold.1.3.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.3.trip = 0
overCurrentProtectorSensorLowerWarningThreshold.1.4.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.4.trip = 0
overCurrentProtectorSensorLowerWarningThreshold.1.5.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.5.trip = 0
overCurrentProtectorSensorLowerWarningThreshold.1.6.rmsCurrent = 0
overCurrentProtectorSensorLowerWarningThreshold.1.6.trip = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorUpperWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0404s]
STDOUT[
overCurrentProtectorSensorUpperWarningThreshold.1.1.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.1.trip = 0
overCurrentProtectorSensorUpperWarningThreshold.1.2.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.2.trip = 0
overCurrentProtectorSensorUpperWarningThreshold.1.3.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.3.trip = 0
overCurrentProtectorSensorUpperWarningThreshold.1.4.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.4.trip = 0
overCurrentProtectorSensorUpperWarningThreshold.1.5.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.5.trip = 0
overCurrentProtectorSensorUpperWarningThreshold.1.6.rmsCurrent = 130
overCurrentProtectorSensorUpperWarningThreshold.1.6.trip = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' overCurrentProtectorSensorUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0584s]
STDOUT[
overCurrentProtectorSensorUpperCriticalThreshold.1.1.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.1.trip = 0
overCurrentProtectorSensorUpperCriticalThreshold.1.2.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.2.trip = 0
overCurrentProtectorSensorUpperCriticalThreshold.1.3.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.3.trip = 0
overCurrentProtectorSensorUpperCriticalThreshold.1.4.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.4.trip = 0
overCurrentProtectorSensorUpperCriticalThreshold.1.5.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.5.trip = 0
overCurrentProtectorSensorUpperCriticalThreshold.1.6.rmsCurrent = 160
overCurrentProtectorSensorUpperCriticalThreshold.1.6.trip = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOverCurrentProtectorSensorIsAvailable]

CMD EXITCODE[0]
CMD RUNTIME[0.0485s]
STDOUT[
measurementsOverCurrentProtectorSensorIsAvailable.1.1.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.1.trip = true
measurementsOverCurrentProtectorSensorIsAvailable.1.2.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.2.trip = true
measurementsOverCurrentProtectorSensorIsAvailable.1.3.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.3.trip = true
measurementsOverCurrentProtectorSensorIsAvailable.1.4.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.4.trip = true
measurementsOverCurrentProtectorSensorIsAvailable.1.5.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.5.trip = true
measurementsOverCurrentProtectorSensorIsAvailable.1.6.rmsCurrent = true
measurementsOverCurrentProtectorSensorIsAvailable.1.6.trip = true
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOverCurrentProtectorSensorState]

CMD EXITCODE[0]
CMD RUNTIME[0.0503s]
STDOUT[
measurementsOverCurrentProtectorSensorState.1.1.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.1.trip = closed
measurementsOverCurrentProtectorSensorState.1.2.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.2.trip = closed
measurementsOverCurrentProtectorSensorState.1.3.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.3.trip = closed
measurementsOverCurrentProtectorSensorState.1.4.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.4.trip = closed
measurementsOverCurrentProtectorSensorState.1.5.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.5.trip = closed
measurementsOverCurrentProtectorSensorState.1.6.rmsCurrent = normal
measurementsOverCurrentProtectorSensorState.1.6.trip = closed
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsOverCurrentProtectorSensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0453s]
STDOUT[
measurementsOverCurrentProtectorSensorValue.1.1.rmsCurrent = 23
measurementsOverCurrentProtectorSensorValue.1.1.trip = 0
measurementsOverCurrentProtectorSensorValue.1.2.rmsCurrent = 0
measurementsOverCurrentProtectorSensorValue.1.2.trip = 0
measurementsOverCurrentProtectorSensorValue.1.3.rmsCurrent = 7
measurementsOverCurrentProtectorSensorValue.1.3.trip = 0
measurementsOverCurrentProtectorSensorValue.1.4.rmsCurrent = 15
measurementsOverCurrentProtectorSensorValue.1.4.trip = 0
measurementsOverCurrentProtectorSensorValue.1.5.rmsCurrent = 0
measurementsOverCurrentProtectorSensorValue.1.5.trip = 0
measurementsOverCurrentProtectorSensorValue.1.6.rmsCurrent = 0
measurementsOverCurrentProtectorSensorValue.1.6.trip = 0
]
SNMP STATUS[TRUE]
Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.1.1, index: 1.1.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.1, scale: 0.1, limits: (, , 13, 16), CURRENT: 2.3, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.1.1')]
SQL RUNTIME[0.00102496s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.1.1']
SQL RUNTIME[0.00053000s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4967' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00039697s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4967' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00031209s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.1.15, index: measurementsOverCurrentProtectorSensorState.1.1.15, type: pdu2-sensorstate, descr: Over Current Protector 1.1, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.1.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00058794s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.1.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00054002s]
.Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.2.1, index: 1.2.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.2, scale: 0.1, limits: (, , 13, 16), CURRENT: 0, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.2.1')]
SQL RUNTIME[0.00048399s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.2.1']
SQL RUNTIME[0.00048280s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4968' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027704s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4968' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00029182s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.2.15, index: measurementsOverCurrentProtectorSensorState.1.2.15, type: pdu2-sensorstate, descr: Over Current Protector 1.2, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.2.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00043392s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.2.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00048685s]
.Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.3.1, index: 1.3.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.3, scale: 0.1, limits: (, , 13, 16), CURRENT: 0.7, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.3.1')]
SQL RUNTIME[0.00047517s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.3.1']
SQL RUNTIME[0.00054717s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4969' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027490s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4969' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00024605s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.3.15, index: measurementsOverCurrentProtectorSensorState.1.3.15, type: pdu2-sensorstate, descr: Over Current Protector 1.3, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.3.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00045800s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.3.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00047493s]
.Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.4.1, index: 1.4.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.4, scale: 0.1, limits: (, , 13, 16), CURRENT: 1.5, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.4.1')]
SQL RUNTIME[0.00043702s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.4.1']
SQL RUNTIME[0.00059581s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4970' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025606s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4970' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00033903s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.4.15, index: measurementsOverCurrentProtectorSensorState.1.4.15, type: pdu2-sensorstate, descr: Over Current Protector 1.4, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.4.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00042415s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.4.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00054407s]
.Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.5.1, index: 1.5.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.5, scale: 0.1, limits: (, , 13, 16), CURRENT: 0, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.5.1')]
SQL RUNTIME[0.00066710s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.5.1']
SQL RUNTIME[0.00053501s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4971' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027013s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4971' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00030208s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.5.15, index: measurementsOverCurrentProtectorSensorState.1.5.15, type: pdu2-sensorstate, descr: Over Current Protector 1.5, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.5.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00042105s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.5.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041485s]
.Discover sensor: [class: current, device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.4.1.6.1, index: 1.6.1, type: PDU2-MIB-measurementsOverCurrentProtectorSensorValue, descr: Over Current Protector 1.6, scale: 0.1, limits: (, , 13, 16), CURRENT: 0, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.6.1')]
SQL RUNTIME[0.00044894s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '153' AND `sensor_type` = 'PDU2-MIB-measurementsOverCurrentProtectorSensorValue' AND `sensor_index` = '1.6.1']
SQL RUNTIME[0.00043893s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4972' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026202s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4972' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00029111s]
.Discover status: [device: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net, oid: .1.3.6.1.4.1.13742.6.5.3.3.1.3.1.6.15, index: measurementsOverCurrentProtectorSensorState.1.6.15, type: pdu2-sensorstate, descr: Over Current Protector 1.6, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.6.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00042796s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `status_type` = 'pdu2-sensorstate' AND `status_index` = 'measurementsOverCurrentProtectorSensorState.1.6.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00046301s]
.
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorName]

CMD EXITCODE[0]
CMD RUNTIME[0.0699s]
STDOUT[
externalSensorName = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorDescription]

CMD EXITCODE[0]
CMD RUNTIME[0.0709s]
STDOUT[
externalSensorDescription = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorType]

CMD EXITCODE[0]
CMD RUNTIME[0.066s]
STDOUT[
externalSensorType = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorUnits]

CMD EXITCODE[0]
CMD RUNTIME[0.0657s]
STDOUT[
externalSensorUnits = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorDecimalDigits]

CMD EXITCODE[0]
CMD RUNTIME[0.0631s]
STDOUT[
externalSensorDecimalDigits = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorEnabledThresholds]

CMD EXITCODE[0]
CMD RUNTIME[0.0632s]
STDOUT[
externalSensorEnabledThresholds = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0626s]
STDOUT[
externalSensorLowerCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorLowerWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0606s]
STDOUT[
externalSensorLowerWarningThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorUpperWarningThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0655s]
STDOUT[
externalSensorUpperWarningThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' externalSensorUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0661s]
STDOUT[
externalSensorUpperCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsExternalSensorIsAvailable]

CMD EXITCODE[0]
CMD RUNTIME[0.064s]
STDOUT[
measurementsExternalSensorIsAvailable = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsExternalSensorState]

CMD EXITCODE[0]
CMD RUNTIME[0.0639s]
STDOUT[
measurementsExternalSensorState = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PDU2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/raritan 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' measurementsExternalSensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0651s]
STDOUT[
measurementsExternalSensorValue = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o ENTITY-SENSOR-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0348s]
STDOUT[
entPhySensorValue = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00169587s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00057507s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00050998s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00032210s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00039101s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00076008s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00086689s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00050187s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00055790s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00039291s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00042796s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00048494s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030589s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00033617s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00041914s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00061297s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027585s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028300s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026894s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027204s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027609s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026703s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026298s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026107s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027108s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030994s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026584s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027394s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00025892s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026298s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028205s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '153' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026798s]

SQL[SELECT * FROM `status` WHERE `device_id` = '153' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00034595s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '153' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00033522s]


 o Duration             3.2746s

#####  Module Start: storage  #####

 o UCD-SNMP-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' dskEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0497s]
STDOUT[
dskEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0269s]
STDOUT[
hrStorageEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `storage` WHERE `device_id` = '153']
SQL RUNTIME[0.00055623s]

 o Duration             0.0837s

#####  Module Start: neighbours  #####

 o LLDP-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' lldpRemChassisIdSubtype]

CMD EXITCODE[0]
CMD RUNTIME[0.042s]
STDOUT[
lldpRemChassisIdSubtype = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o CISCO-CDP-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' cdpCache]

CMD EXITCODE[0]
CMD RUNTIME[0.091s]
STDOUT[
cdpCache = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `neighbours` WHERE `device_id` = '153']
SQL RUNTIME[0.00076389s]



 o Duration             0.1413s

#####  Module Start: arp-table  #####


SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '153' GROUP BY `port_id`]
SQL RUNTIME[0.00043893s]

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' ipNetToPhysicalPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0385s]
STDOUT[
ipNetToPhysicalPhysAddress[2][ipv4]["172.29.41.1"] 8:55:31:a2:62:47
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToPhysicalPhysAddress

SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M LEFT JOIN ports AS I ON M.port_id = I.port_id WHERE I.device_id = '153']
SQL RUNTIME[0.00070715s]
.

 o Duration             0.0448s

Module [junose-atm-vp] blacklisted by os definition in process [discovery].
Module [bgp-peers] disabled by os definition in process [discovery].
#####  Module Start: mac-accounting  #####


 o Duration             0.0004s

#####  Module Start: sla  #####

 o DISMAN-PING-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' pingCtlEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0311s]
STDOUT[
pingCtlEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `slas` WHERE `device_id` = '153']
SQL RUNTIME[0.00053096s]

 o Duration             0.0354s

Module [lsp] disabled globally by config in process [discovery].
Module [pseudowires] disabled by os definition in process [discovery].
#####  Module Start: virtual-machines  #####



 o Duration             0.0013s

Module [cisco-cbqos] blacklisted by os definition in process [discovery].
#####  Module Start: ucd-diskio  #####


CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net':'161' diskIOEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0292s]
STDOUT[
diskIOEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '153']
SQL RUNTIME[0.00046086s]


 o Duration             0.0324s

Module [wifi] disabled for device type 'power'. in process [discovery].
Module [p2p-radios] disabled by os definition in process [discovery].
#####  Module Start: graphs  #####


 o Duration             0.001s

Module [raid] disabled by os definition in process [discovery].
 o Modules Excluded     vrf, junose-atm-vp, cisco-cbqos
 o Modules Disabled     ports-stack, vlans, bgp-peers, lsp, pseudowires, wifi, p2p-radios, raid
 o Modules Enabled      os, mibs, ports, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage, neighbours,
                        arp-table,mac-accounting, sla, virtual-machines, ucd-diskio, graphs

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '153';]
SQL RUNTIME[0.00034308s]

SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='4.7648',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:20:{s:6:\"system\";d:0.2194;s:2:\"os\";d:0.1948;s:7:\"sensors\";d:0.0642;s:6:\"status\";d:0.0569;s:7:\"counter\";d:0.035;s:10:\"processors\";d:0.1571;s:8:\"mempools\";d:0.0013;s:7:\"storage\";d:0.0053;s:7:\"ucd-mib\";d:0.0619;s:13:\"ipSystemStats\";d:0.0739;s:5:\"ports\";d:0.3999;s:15:\"printersupplies\";d:0.001;s:10:\"ucd-diskio\";d:0.0007;s:4:\"ospf\";d:0.0002;s:3:\"sla\";d:0.0011;s:14:\"mac-accounting\";d:0.0014;s:15:\"entity-physical\";d:0.0004;s:12:\"applications\";d:0.0009;s:9:\"fdb-table\";d:0.0451;s:6:\"graphs\";d:0.0692;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.09198188781738281;s:13:\"EtherLike-MIB\";d:0.08143806457519531;s:12:\"Q-BRIDGE-MIB\";d:0.13265609741210938;s:6:\"IP-MIB\";d:0.07022309303283691;}s:14:\"poller_history\";a:288:{i:1682432060;d:1.4616;i:1682431849;d:1.3497;i:1682431684;d:3.5116;i:1682431502;d:1.9933;i:1682431347;d:4.5859;i:1682431138;d:1.2865;i:1682430940;d:2.1592;i:1682430788;d:3.2706;i:1682430613;d:1.4056;i:1682430423;d:1.3249;i:1682430250;d:1.9058;i:1682430069;d:1.35;i:1682429862;d:1.4028;i:1682429714;d:3.4777;i:1682429556;d:1.4308;i:1682429341;d:1.3738;i:1682429151;d:1.7896;i:1682428984;d:2.755;i:1682428818;d:1.4237;i:1682428616;d:1.33;i:1682428442;d:2.4828;i:1682428272;d:2.2393;i:1682428071;d:1.5437;i:1682427905;d:4.3717;i:1682427752;d:5.5707;i:1682427578;d:3.4938;i:1682427370;d:1.3805;i:1682427185;d:1.3605;i:1682427015;d:1.9218;i:1682426831;d:1.3615;i:1682426648;d:1.3462;i:1682426474;d:1.3279;i:1682426287;d:1.3127;i:1682426114;d:1.3651;i:1682425928;d:1.3088;i:1682425750;d:1.3424;i:1682425578;d:1.3665;i:1682425366;d:1.3331;i:1682425211;d:4.219;i:1682425013;d:1.3497;i:1682424847;d:2.8519;i:1682424662;d:1.3012;i:1682424474;d:2.5042;i:1682424304;d:2.0928;i:1682424140;d:1.7959;i:1682423941;d:1.2851;i:1682423767;d:1.3005;i:1682423581;d:1.3303;i:1682423413;d:2.0528;i:1682423229;d:1.2981;i:1682423048;d:1.243;i:1682422840;d:1.2396;i:1682422626;d:3.9752;i:1682422507;d:8.7493;i:1682422344;d:1.2559;i:1682422138;d:1.2371;i:1682421960;d:1.268;i:1682421787;d:1.3086;i:1682421610;d:1.3056;i:1682421406;d:1.2817;i:1682421249;d:2.3933;i:1682421040;d:1.2843;i:1682420879;d:4.0724;i:1682420701;d:1.3641;i:1682420504;d:1.2987;i:1682420333;d:3.889;i:1682420161;d:1.3771;i:1682419953;d:1.3213;i:1682419806;d:4.5442;i:1682419631;d:1.36;i:1682419415;d:1.2497;i:1682419265;d:4.4987;i:1682419076;d:1.3041;i:1682418911;d:3.4977;i:1682418712;d:2.1115;i:1682418543;d:3.2817;i:1682418338;d:1.3163;i:1682418167;d:3.9811;i:1682417995;d:3.3454;i:1682417826;d:2.1868;i:1682417658;d:2.0955;i:1682417448;d:1.236;i:1682417295;d:4.96;i:1682417110;d:1.2502;i:1682416932;d:1.3271;i:1682416760;d:1.3008;i:1682416572;d:1.2419;i:1682416363;d:1.237;i:1682416187;d:2.671;i:1682416019;d:4.1596;i:1682415855;d:1.8178;i:1682415658;d:1.3256;i:1682415480;d:1.3882;i:1682415288;d:1.8844;i:1682415116;d:3.9451;i:1682414915;d:1.73;i:1682414767;d:4.2788;i:1682414592;d:1.2672;i:1682414403;d:1.2556;i:1682414238;d:1.2893;i:1682414014;d:1.2487;i:1682413882;d:4.1081;i:1682413692;d:1.3084;i:1682413506;d:1.2702;i:1682413302;d:1.3178;i:1682413142;d:3.2915;i:1682412966;d:1.2778;i:1682412788;d:1.3201;i:1682412607;d:1.2804;i:1682412432;d:1.8277;i:1682412253;d:1.2414;i:1682412058;d:1.2854;i:1682411883;d:1.2909;i:1682411700;d:1.3288;i:1682411536;d:1.9079;i:1682411351;d:1.2258;i:1682411175;d:1.3436;i:1682410960;d:1.2632;i:1682410794;d:3.874;i:1682410608;d:1.9528;i:1682410452;d:3.3157;i:1682410228;d:1.3474;i:1682410088;d:5.1539;i:1682409912;d:1.5385;i:1682409706;d:1.2407;i:1682409556;d:4.2159;i:1682409363;d:1.2268;i:1682409173;d:1.2929;i:1682408998;d:2.5809;i:1682408834;d:2.0461;i:1682408654;d:1.2733;i:1682408441;d:1.3089;i:1682408254;d:4.507;i:1682408089;d:3.8127;i:1682407929;d:2.215;i:1682407707;d:1.2593;i:1682407567;d:4.2972;i:1682407379;d:1.2575;i:1682407200;d:1.3813;i:1682407054;d:1.9588;i:1682406792;d:1.3009;i:1682406681;d:7.436;i:1682406492;d:1.6516;i:1682406312;d:1.3797;i:1682406137;d:1.3902;i:1682405973;d:1.4583;i:1682405785;d:1.3635;i:1682405609;d:1.4302;i:1682405459;d:1.4745;i:1682405230;d:1.3474;i:1682405012;d:1.3565;i:1682404778;d:5.0387;i:1682404668;d:10.95;i:1682404489;d:1.3373;i:1682404394;d:1.397;i:1682404148;d:1.8861;i:1682403970;d:1.315;i:1682403783;d:1.2947;i:1682403581;d:1.2888;i:1682403398;d:4.36;i:1682403248;d:4.7862;i:1682403068;d:1.2981;i:1682402889;d:1.3287;i:1682402681;d:1.2917;i:1682402530;d:4.7728;i:1682402348;d:1.303;i:1682402147;d:1.2795;i:1682401985;d:2.4456;i:1682401806;d:1.2777;i:1682401631;d:1.2548;i:1682401448;d:1.2747;i:1682401273;d:1.7876;i:1682401092;d:1.2483;i:1682400895;d:1.2787;i:1682400743;d:2.3468;i:1682400557;d:1.2626;i:1682400348;d:1.2456;i:1682400157;d:3.7076;i:1682400001;d:4.5514;i:1682399837;d:1.4134;i:1682399648;d:1.3527;i:1682399472;d:1.9244;i:1682399264;d:1.2938;i:1682399095;d:2.7391;i:1682398943;d:1.3632;i:1682398720;d:1.3214;i:1682398563;d:2.616;i:1682398369;d:1.3617;i:1682398208;d:2.3081;i:1682398028;d:1.3197;i:1682397843;d:1.2554;i:1682397671;d:1.312;i:1682397482;d:1.2324;i:1682397296;d:1.9075;i:1682397139;d:4.0688;i:1682396959;d:1.248;i:1682396774;d:1.2907;i:1682396594;d:1.3091;i:1682396383;d:1.329;i:1682396195;d:4.4755;i:1682396043;d:3.7941;i:1682395884;d:1.299;i:1682395686;d:1.3317;i:1682395516;d:2.2132;i:1682395331;d:1.3492;i:1682395144;d:1.4524;i:1682394937;d:2.0062;i:1682394788;d:2.8943;i:1682394608;d:1.5586;i:1682394445;d:2.3245;i:1682394259;d:1.3581;i:1682394042;d:1.3143;i:1682393874;d:3.4563;i:1682393735;d:3.5811;i:1682393543;d:1.2817;i:1682393358;d:1.6078;i:1682393182;d:1.2608;i:1682393009;d:1.3642;i:1682392828;d:1.2859;i:1682392644;d:1.3007;i:1682392425;d:1.2967;i:1682392258;d:5.8482;i:1682392094;d:3.2522;i:1682391906;d:1.6074;i:1682391756;d:2.389;i:1682391518;d:1.3467;i:1682391353;d:4.0589;i:1682391182;d:2.9231;i:1682391021;d:2.3428;i:1682390843;d:1.42;i:1682390655;d:1.3001;i:1682390453;d:1.7238;i:1682390285;d:2.3717;i:1682390117;d:2.0531;i:1682389937;d:1.5891;i:1682389760;d:2.0607;i:1682389576;d:1.3377;i:1682389374;d:1.3838;i:1682389192;d:3.4945;i:1682388994;d:1.8913;i:1682388854;d:5.4881;i:1682388682;d:1.3366;i:1682388460;d:1.3741;i:1682388316;d:4.289;i:1682388158;d:1.6123;i:1682387960;d:1.3466;i:1682387769;d:1.2946;i:1682387602;d:1.3596;i:1682387397;d:1.3058;i:1682387231;d:3.0834;i:1682387057;d:1.3988;i:1682386859;d:1.3545;i:1682386659;d:2.1032;i:1682386505;d:3.6907;i:1682386312;d:1.7046;i:1682386150;d:3.2248;i:1682385948;d:1.4056;i:1682385796;d:2.9736;i:1682385573;d:1.3107;i:1682385410;d:4.5527;i:1682385247;d:2.7855;i:1682385073;d:1.3157;i:1682384887;d:1.2818;i:1682384720;d:1.3292;i:1682384541;d:1.3309;i:1682384350;d:1.3667;i:1682384177;d:1.3299;i:1682383970;d:1.3296;i:1682383815;d:3.131;i:1682383610;d:1.4299;i:1682383448;d:3.2976;i:1682383264;d:1.4083;i:1682383093;d:1.8507;i:1682382880;d:1.2921;i:1682382759;d:4.7606;i:1682382549;d:1.3719;i:1682382375;d:1.3648;i:1682382188;d:1.3564;i:1682382017;d:1.3534;i:1682381811;d:1.3117;i:1682381661;d:3.6913;i:1682381487;d:1.3208;i:1682381292;d:1.3153;i:1682381117;d:1.3048;i:1682380946;d:1.3824;i:1682380732;d:1.3207;i:1682380580;d:3.5702;i:1682380374;d:1.3048;}s:17:\"discovery_history\";a:13:{i:1682432186;d:4.7648;i:1682419010;d:5.0272;i:1682397404;d:5.0119;i:1682375802;d:5.1826;i:1682354205;d:5.017;i:1682332605;d:5.1667;i:1682311013;d:4.894;i:1682289397;d:5.0707;i:1682267807;d:4.6989;i:1682246198;d:4.4897;i:1682224591;d:5.0496;i:1682202965;d:4.6953;i:1682195701;d:14.5877;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.1447;s:4:\"mibs\";d:0.1422;s:5:\"ports\";d:0.1729;s:4:\"oids\";d:0.0023;s:12:\"ip-addresses\";d:0.2364;s:10:\"processors\";d:0.0741;s:8:\"mempools\";d:0.0617;s:9:\"inventory\";d:0.2114;s:15:\"printersupplies\";d:0.0018;s:7:\"sensors\";d:3.2746;s:7:\"storage\";d:0.0837;s:10:\"neighbours\";d:0.1413;s:9:\"arp-table\";d:0.0448;s:14:\"mac-accounting\";d:0.0004;s:3:\"sla\";d:0.0354;s:16:\"virtual-machines\";d:0.0013;s:10:\"ucd-diskio\";d:0.0324;s:6:\"graphs\";d:0.001;}}' WHERE `device_id` = '153']
SQL RUNTIME[0.54972386s]
#####  pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net [153] completed discovery modules at 2023-04-25 10:16:32  #####

 o Discovery time       4.7648 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '9236' AND `process_name` = 'discovery.php' AND `device_id` = '153' AND `poller_id` = '0']
SQL RUNTIME[0.00408387s]
#####  Finished discovery run at 2023-04-25 10:16:32  #####


SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00036192s]
Cached 12 alert rules.

SQL[SELECT * FROM `alert_assoc`]
SQL RUNTIME[0.00020814s]

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') = '40' AND `ports`.`ifName` = 'Ethernet1/47') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00404978s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '1']
SQL RUNTIME[0.00039005s]
Alert Checker              'Cogent Above 5G': 1 existing, 1 new entries (+0/-0).

SQL[SELECT `processor_id`, `devices`.`device_id` as `device_id` FROM `processors` LEFT JOIN `devices` ON (`processors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`vendor`, '') = 'Cisco')]
SQL RUNTIME[0.00162911s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '3']
SQL RUNTIME[0.00065303s]
Alert Checker                    'Cisco CPU': 30 existing, 30 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`device_id`, '') != '3')]
SQL RUNTIME[0.00039887s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '4']
SQL RUNTIME[0.00078702s]
Alert Checker                  'Device down': 87 existing, 87 new entries (+0/-0).

SQL[SELECT `mempool_id`, `devices`.`device_id` as `device_id` FROM `mempools` LEFT JOIN `devices` ON (`mempools`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') != '3') AND `mempools`.`mempool_deleted` != '1']
SQL RUNTIME[0.00075698s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '5']
SQL RUNTIME[0.00090981s]
Alert Checker           'RAM usage is high ': 113 existing, 113 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`device_id`, '') != '3')]
SQL RUNTIME[0.00029898s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '7']
SQL RUNTIME[0.00063300s]
Alert Checker               'Device Warning': 87 existing, 87 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') = '41' AND `ports`.`ifName` = 'Ethernet1/48') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00303102s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '8']
SQL RUNTIME[0.00028586s]
Alert Checker            'Zayo Above 4 Gbps': 1 existing, 1 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') = '41' AND `ports`.`ifName` = 'Ethernet1/47') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00461793s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '9']
SQL RUNTIME[0.00037909s]
Alert Checker                 'QIX Above 4G': 1 existing, 1 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('42','43','40','38','41','44','39','45')) AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00789189s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '10']
SQL RUNTIME[0.00268102s]
Alert Checker                'Error on port': 401 existing, 401 new entries (+0/-0).
  String '399760' transformed by action [asdot] to: '399760'
  String '212232' transformed by action [asdot] to: '212232'
  String '397601' transformed by action [asdot] to: '397601'

SQL[SELECT `bgpPeer_id`, `devices`.`device_id` as `device_id` FROM `bgpPeers` LEFT JOIN `devices` ON (`bgpPeers`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('67','65','50','44','58') AND IFNULL(`bgpPeers`.`bgpPeerRemoteAs`, '') != '399760' AND IFNULL(`bgpPeers`.`bgpPeerRemoteAs`, '') != '212232' AND IFNULL(`bgpPeers`.`bgpPeerRemoteAs`, '') != '397601')]
SQL RUNTIME[0.00147605s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '11']
SQL RUNTIME[0.00113797s]
Alert Checker             'BGP Session down': 156 existing, 156 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`ports`.`port_descr_type`, "") LIKE 'Core%') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00288081s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '12']
SQL RUNTIME[0.00041914s]
Alert Checker               'Core Port Down': 21 existing, 21 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'network' AND IFNULL(`sensors`.`sensor_class`, '') = 'temperature') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00554109s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '13']
SQL RUNTIME[0.00263190s]
Alert Checker         'Critical temperature': 506 existing, 506 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`type`, '') = 'network' AND IFNULL(`sensors`.`sensor_class`, '') = 'temperature' AND IFNULL(`sensors`.`sensor_descr`, "") LIKE '%Inlet%') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00287199s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '14']
SQL RUNTIME[0.00056291s]
Alert Checker       'High Inlet Temperature': 34 existing, 34 new entries (+0/-0).
./discovery.php: pdu-a.ml-4-1b-05.dm4a.2900mc.hivedc.net - 1 devices discovered in 7.497 secs

SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1682417784']
SQL RUNTIME[0.00025916s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       7.497 secs
 o Memory usage         28MB (peak: 28MB)
 o MySQL Usage          Cell[37/0.045s] Row[57/0.062s] Rows[89/0.231s] Column[2/0.003s] Update[8/1.993s] Insert[1/0.093s] Delete[1/0.005s]
 o RRDTool Usage
root@fabric:/opt/observium#