CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0152s]
CMD EXITDELAY[10ms]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: https://svn.observium.org/svn/observium/branches/stable
Relative URL: ^/observium/branches/stable
Repository Root: https://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 12523
Node Kind: directory
Schedule: normal
Last Changed Author: adama
Last Changed Rev: 12520
Last Changed Date: 2023-02-08 20:28:14 +0100 (Wed, 08 Feb 2023)

]
DEFINITIONS loaded by: 0.15519 ms

DEFINITIONS in memory: 15.5MB


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00040698s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00014114s]

SQL[SET SESSION `sql_mode` = 'NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00012803s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00014901s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00025105s]

CMD[/bin/hostname -f]

CMD EXITCODE[0]
CMD RUNTIME[0.0025s]
STDOUT[
vm-observium
]

SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)]
SQL RUNTIME[0.00029111s]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                          Observium Professional 23.2.12520
                                  https://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.0196s]
STDOUT[
Linux|5.15.0-58-generic|amd64|Ubuntu|20.04|vmware|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0034s]
STDOUT[
Python 3.8.10
]

SQL[SELECT version();]
SQL RUNTIME[0.00021100s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0036s]
STDOUT[
NET-SNMP version: 5.8
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0094s]
STDOUT[
RRDtool 1.7.2  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0025s]
CMD EXITDELAY[10ms]
STDOUT[
/usr/bin/fping: Version 4.2
/usr/bin/fping: comments to david@schweikert.ch
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0467s]
STDOUT[
Apache/2.4.41
]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';]
SQL RUNTIME[0.00036597s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00020909s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';]
SQL RUNTIME[0.00018311s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00013208s]

SQL[SHOW VARIABLES LIKE 'log_bin']
SQL RUNTIME[0.17079616s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00198984s]

#####  Software versions  #####

 o OS                   Linux 5.15.0-58-generic [amd64] (Ubuntu 20.04)
 o Apache               2.4.41
 o PHP                  7.4.3-4ubuntu2.17 (OPcache: DISABLED)
 o Python               3.8.10
 o MySQL                8.0.32-0ubuntu0.20.04.2 (extension: mysqli 7.4.3-4ubuntu2.17)
 o SNMP                 NET-SNMP 5.8
 o RRDtool              1.7.2
 o Fping                4.2 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  Unlimited

#####  DB info  #####

 o DB schema            478
 o MySQL binlog         ON
 o MySQL mode           NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8mb3

#####  Timezones info  #####

 o Date                 Monday, 13-Feb-23 15:15:43 CET
 o PHP                  +01:00
 o MySQL                +01:00


SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1676297743' AND `maint_end` > '1676297743']
SQL RUNTIME[0.00034118s]
#####  Starting polling run at 2023-02-13 15:15:43  #####


SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `device_id` = '169' AND `poller_id` = '0' ORDER BY `device_id` ASC]
SQL RUNTIME[0.00027394s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '169']
SQL RUNTIME[0.00033808s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169']
SQL RUNTIME[0.00032997s]


  /opt/observium/includes/polling/functions.inc.php:119 
array(
  [device_id]                 => string(3) "169"
  [poller_id]                 => string(1) "0"
  [hostname]                  => string(13) "172.21.99.138"
  [sysName]                   => string(3) "nmc"
  [label]                     => null
  [ip]                        => string(13) "172.21.99.138"
  [snmp_community]            => string(7) "private"
  [snmp_authlevel]            => null
  [snmp_authname]             => null
  [snmp_authpass]             => null
  [snmp_authalgo]             => null
  [snmp_cryptopass]           => null
  [snmp_cryptoalgo]           => null
  [snmp_context]              => null
  [snmpable]                  => null
  [snmp_version]              => string(2) "v1"
  [snmp_port]                 => string(3) "161"
  [snmp_timeout]              => null
  [snmp_retries]              => null
  [snmp_maxrep]               => null
  [ssh_port]                  => string(2) "22"
  [agent_version]             => null
  [snmp_transport]            => string(3) "udp"
  [bgpLocalAs]                => null
  [snmpEngineID]              => string(0) ""
  [sysObjectID]               => string(21) ".1.3.6.1.4.1.935.10.1"
  [sysDescr]                  => string(31) "Network Management Card for UPS"
  [sysContact]                => string(24) "Technical Support Center"
  [version]                   => string(40) "SRV TK UPS: 05649-0599 Firmware: 3.1.0.0"
  [hardware]                  => string(8) "LINE-INT"
  [vendor]                    => string(11) "PowerWalker"
  [features]                  => null
  [location]                  => string(6) "SRV TK"
  [os]                        => string(8) "eppc-ups"
  [status]                    => string(1) "1"
  [status_type]               => string(2) "ok"
  [ignore]                    => string(1) "0"
  [ignore_until]              => null
  [asset_tag]                 => null
  [disabled]                  => string(1) "0"
  [uptime]                    => string(4) "5369"
  [last_rebooted]             => string(10) "1676292173"
  [force_discovery]           => string(1) "0"
  [last_polled]               => string(19) "2023-02-13 15:12:25"
  [last_discovered]           => string(19) "2023-02-13 15:10:16"
  [last_alerter]              => string(19) "2023-02-13 15:12:12"
  [last_polled_timetaken]     => string(4) "4.09"
  [last_discovered_timetaken] => string(4) "4.91"
  [purpose]                   => null
  [type]                      => string(5) "power"
  [serial]                    => null
  [icon]                      => null
  [device_state]              => string(2333) "a:5:{s:15:"poller_mod_perf";a:23:{s:6:"system";d:0.1671;s:2:"os";d:0.1264;s:7:"sensors";d:0.354;s:6:"status";d:0.0536;s:7:"counter";d:0.0013;s:10:"processors";d:0.0021;s:8:"mempools";d:0.0012;s:7:"storage";d:0.0021;s:7:"ucd-mib";d:0.1503;s:13:"ipSystemStats";d:1.1039;s:5:"ports";d:1.8708;s:15:"printersupplies";d:0.0012;s:10:"ucd-diskio";d:0.0009;s:4:"ospf";d:0.0001;s:3:"sla";d:0.0014;s:14:"mac-accounting";d:0.0014;s:12:"loadbalancer";d:0.0003;s:15:"entity-physical";d:0.0002;s:12:"applications";d:0.0017;s:9:"fdb-table";d:0.0863;s:6:"graphs";d:0.0736;s:4:"oids";d:0.0012;s:6:"probes";d:0.0011;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.4544258117675781;s:13:"EtherLike-MIB";d:0.034970998764038086;s:12:"Q-BRIDGE-MIB";d:1.1510851383209229;s:6:"IP-MIB";d:0.1913011074066162;}s:14:"poller_history";a:42:{i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:"discovery_history";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:"discovery_mod_perf";a:18:{s:2:"os";d:0.1205;s:4:"mibs";d:0.2058;s:5:"ports";d:0.2178;s:4:"oids";d:0.0018;s:12:"ip-addresses";d:0.3596;s:10:"processors";d:0.0658;s:8:"mempools";d:0.1013;s:9:"inventory";d:0.2745;s:15:"printersupplies";d:0.0014;s:7:"sensors";d:3.1239;s:7:"storage";d:0.0741;s:10:"neighbours";d:0.1398;s:9:"arp-table";d:0.103;s:14:"mac-accounting";d:0.0004;s:3:"sla";d:0.0372;s:16:"virtual-machines";d:0.0008;s:10:"ucd-diskio";d:0.0469;s:6:"graphs";d:0.0006;}}"
  [distro]                    => null
  [distro_ver]                => null
  [kernel]                    => null
  [arch]                      => null
)


  /opt/observium/includes/polling/functions.inc.php:120 
array(
  [override_type] => string(5) "power"
  [ping_skip]     => string(1) "1"
)


  /opt/observium/includes/polling/functions.inc.php:121 
bool(false)

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '169' AND `poller_id` = '0']
SQL RUNTIME[0.00028181s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('3571573','poller.php','3402670','0','php ./poller.php -d -h 169','1676297743','169')]
SQL RUNTIME[0.00209093s]

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00030780s]
Cached 5 alert rules.

SQL[SELECT * FROM `alert_table` WHERE `device_id` = '169']
SQL RUNTIME[0.00029302s]
#####  172.21.99.138 [169]  #####

 o OS                   eppc-ups
 o OS Group             ups
 o Last poll duration   4.09 seconds
 o Last Polled          2023-02-13 15:12:25
 o SNMP Version         v1

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0283s]
STDOUT[
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.935.10.1
.1.3.6.1.2.1.1.3.0 = 0:1:32:51.89
]
SNMP STATUS[TRUE]
 o Device status        Device is reachable by SNMP (28.32ms)
RRD /opt/observium/rrd/172.21.99.138/status.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/status.rrd N:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.03]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/172.21.99.138/ping_snmp.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/ping_snmp.rrd N:28.32]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.03]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169']
SQL RUNTIME[0.00047898s]
Module [unix-agent] excluded in process [poller].
Module [wmi] excluded in process [poller].
Module [ipmi] excluded in process [poller].
Module [netstats] disabled by os definition in process [poller].
Module [bgp-peers] disabled by os definition in process [poller].
Module [junose-atm-vp] excluded in process [poller].
Module [wifi] disabled for device type 'power'. in process [poller].
Module [p2p-radios] disabled by os definition in process [poller].
Module [cisco-ipsec-flow-monitor] excluded in process [poller].
Module [cisco-remote-access-monitor] excluded in process [poller].
Module [cisco-cef] excluded in process [poller].
Module [lsp] disabled globally by config in process [poller].
Module [pseudowires] disabled by os definition in process [poller].
Module [arista-software-ip-forwarding] excluded in process [poller].
Module [cipsec-tunnels] excluded in process [poller].
Module [cisco-cbqos] excluded in process [poller].
Module [cisco-eigrp] excluded in process [poller].
Module [aruba-controller] excluded in process [poller].
Module [cisco-vpdn] excluded in process [poller].
Module [packages] disabled globally by config in process [poller].
 o Modules Excluded     unix-agent, wmi, ipmi, junose-atm-vp, cisco-ipsec-flow-monitor, cisco-remote-access-monitor, cisco-cef, 
                        arista-software-ip-forwarding,cipsec-tunnels, cisco-cbqos, cisco-eigrp, aruba-controller, cisco-vpdn 
 o Modules Disabled     netstats, bgp-peers, wifi, p2p-radios, lsp, pseudowires, packages
 o Modules Enabled      system, os, sensors, status, counter, processors, mempools, storage, ucd-mib, ipSystemStats, ports, printersupplies, 
                        ucd-diskio,ospf, sla, mac-accounting, loadbalancer, entity-physical, applications, fdb-table, graphs, oids, processes, 
                        probes


including: includes/polling/system.inc.php
#####  Module Start: system  #####

JSON DECODE[Not string passed]
JSON RAW[


 > $str /opt/observium/includes/common.inc.php:5437 
null

]
JSON DECODE[Not string passed]
JSON RAW[


  /opt/observium/includes/common.inc.php:5437 
null

]

SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00027204s]
 o SNMPv2-MIB           
CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0353s]
STDOUT[
sysUpTime.0 = 0:1:32:51.93
sysLocation.0 = "53 52 56 20 54 4B "
sysContact.0 = "54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 43 65 6E 74 65 72 "
sysName.0 = "4E 4D 43 "
]
SNMP Hex string converted..
   HEX: 53 52 56 20 54 4B 
STRING: SRV TK

SNMP Hex string converted..
   HEX: 54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 43 65 6E 74 65 72 
STRING: Technical Support Center

SNMP Hex string converted..
   HEX: 4E 4D 43 
STRING: NMC

SNMP STATUS[TRUE]
Timeticks converted 0:1:32:51.93 -> 5571

CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0235s]
STDOUT[
"4E 65 74 77 6F 72 6B 20 4D 61 6E 61 67 65 6D 65 6E 74 20 43 61 72 64 20 66 6F 72 20 55 50 53 "
]
SNMP Hex string converted..
   HEX: 4E 65 74 77 6F 72 6B 20 4D 61 6E 61 67 65 6D 65 6E 74 20 43 61 72 64 20 66 6F 72 20 55 50 53 
STRING: Network Management Card for UPS

SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0239s]
STDOUT[
.1.3.6.1.4.1.935.10.1
]
SNMP STATUS[TRUE]

Using SNMP Agent sysUpTime (5571 sec. => 1h 32m 51s)
RRD /opt/observium/rrd/172.21.99.138/uptime.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/uptime.rrd N:5571]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.13]
RRD_STATUS[TRUE]

 o Uptime               1h 32m 51s
 o Last reboot          2023-02-13 13:42:53


  /opt/observium/includes/polling/system.inc.php:218 
array(
  [use]           => string(9) "sysUpTime"
  [sysUpTime]     => int(5571)
  [uptime]        => int(5571)
  [formatted]     => string(10) "1h 32m 51s"
  [message]       => string(26) "Using SNMP Agent sysUpTime"
  [previous]      => string(4) "5369"
  [diff]          => int(-202)
  [last_rebooted] => string(10) "1676292173"
  [rebooted]      => int(0)
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3]

CMD EXITCODE[2]
CMD RUNTIME[0.0428s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: .1.3.6.1.4.1.2021.10.1.5.1

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: .1.3.6.1.4.1.2021.10.1.5.2

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: .1.3.6.1.4.1.2021.10.1.5.3
]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';]
SQL RUNTIME[0.00033402s]

SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297743' WHERE `error_id` = '3275']
SQL RUNTIME[0.00191307s]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';]
SQL RUNTIME[0.00031900s]

SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297743' WHERE `error_id` = '3275']
SQL RUNTIME[0.00137401s]
SNMP STATUS[FALSE]
 o sysObjectID          .1.3.6.1.4.1.935.10.1
 o snmpEngineID         
 o sysDescr             Network Management Card for UPS
 o sysName              NMC
 o Location             SRV TK

SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '169']
SQL RUNTIME[0.00023413s]
 o Module time          0.1501s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-system.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-system.rrd N:0.1501]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.19]
RRD_STATUS[TRUE]



including: includes/polling/os.inc.php
#####  Module Start: os  #####


CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEIndentityUPSSerialNumber.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0259s]
STDOUT[
""
]
SNMP STATUS[FALSE]
SNMP ERROR[#1 - Empty response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1' AND `snmp_cmd` = 'snmpget' AND `mib` = 'EPPC-MIB' AND `oid` = 'upsEIndentityUPSSerialNumber.0';]
SQL RUNTIME[0.00045395s]

SQL[UPDATE `snmp_errors` set `error_count` ='43',`updated` ='1676297743',`snmp_options` ='-OQUvx --hexOutputLength=0' WHERE `error_id` = '3276']
SQL RUNTIME[0.00179482s]
 o OS Poller            OS

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputVA.0 upsEIdentityModel.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0303s]
STDOUT[
upsESystemConfigOutputVA.0 = -1
upsEIdentityModel.0 = LINE-INT
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEIdentityDescription.0 upsEIdentityUPSFirmwareVerison.0 upsEIdentityAgentSoftwareVerison.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0446s]
STDOUT[
upsEIdentityDescription.0 = SRV TK
upsEIdentityUPSFirmwareVerison.0 = 05649-0599
upsEIdentityAgentSoftwareVerison.0 = 3.1.0.0
]
SNMP STATUS[TRUE]
 o Type                 Power
 o Vendor               PowerWalker
 o Hardware             LINE-INT
 o Version              SRV TK UPS: 05649-0599 Firmware: 3.1.0.0
 o Features             <empty>
 o Serial               <empty>
 o Asset                <empty>

 o Module time          0.1131s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-os.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-os.rrd N:0.1131]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.30]
RRD_STATUS[TRUE]



including: includes/polling/sensors.inc.php
#####  Module Start: sensors  #####


SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '169' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','power','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','attenuation','snr','dust','concentration','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','distance','illuminance','wavelength','gauge')]
SQL RUNTIME[0.00096512s]

SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '169' AND `entity_type` = 'sensor']
SQL RUNTIME[0.00035214s]

SQL[SELECT DISTINCT `sensor_oid` FROM `sensors` WHERE `device_id` = '169' AND `sensor_deleted` = '0' AND `poller_type` = 'snmp']
SQL RUNTIME[0.00037789s]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.2.0 .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1 .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1 .1.3.6.1.4.1.935.10.1.1.2.18.1.2. .1.3.6.1.4.1.935.10.1.1.2.18.1.3. .1.3.6.1.4.1.935.10.1.1.2.18.1.7. .1.3.6.1.4.1.935.10.1.1.3.2.0 .1.3.6.1.4.1.935.10.1.1.3.3.0 .1.3.6.1.4.1.935.10.1.1.3.4.0 .1.3.6.1.4.1.935.10.1.1.3.5.0]

CMD EXITCODE[1]
CMD RUNTIME[0.0155s]
STDOUT[

]
STDERR[
.1.3.6.1.4.1.935.10.1.1.2.18.1.2.: Unknown Object Identifier ()
.1.3.6.1.4.1.935.10.1.1.2.18.1.3.: Unknown Object Identifier ()
.1.3.6.1.4.1.935.10.1.1.2.18.1.7.: Unknown Object Identifier ()
]
SNMP ERROR[#996 - MIB or oid not found]
SNMP ERROR[#996 - MIB or oid not found]
SNMP STATUS[FALSE]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00090599s]
Checking (snmp) temperature System 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2449"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(11) "temperature"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(29) ".1.3.6.1.4.1.935.10.1.1.2.2.0"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(21) "upsESystemTemperature"
  [sensor_index]              => string(1) "0"
  [sensor_type]               => string(30) "EPPC-MIB-upsESystemTemperature"
  [sensor_descr]              => string(6) "System"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(2) "90"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => null
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(19) "22.9000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297541"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.2.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0234s]
STDOUT[
233
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(233)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-temperature-EPPC-MIB-upsESystemTemperature-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-temperature-EPPC-MIB-upsESystemTemperature-0.rrd N:23.3]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.36]
RRD_STATUS[TRUE]

Checking alert 6 associated by 

Testing: sensor_value > 75
 (value: 23.3)
NOT TRUE
%G[OK]%N
RRD /opt/observium/rrd/172.21.99.138/alert-6-sensor-2449.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-6-sensor-2449.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.36]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00094414s]
Checking (snmp) voltage Input 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2454"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "voltage"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) ".1.3.6.1.4.1.935.10.1.1.2.16.1.3.1"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(22) "upsESystemInputVoltage"
  [sensor_index]              => string(1) "1"
  [sensor_type]               => string(31) "EPPC-MIB-upsESystemInputVoltage"
  [sensor_descr]              => string(5) "Input"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(7) "266.685"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(7) "197.115"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(20) "233.8000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297541"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1]

CMD EXITCODE[0]
CMD RUNTIME[0.0237s]
STDOUT[
2328
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(2328)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemInputVoltage-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemInputVoltage-1.rrd N:232.8]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.39]
RRD_STATUS[TRUE]

Checking (snmp) voltage Output 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2456"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "voltage"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.3."
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(23) "upsESystemOutputVoltage"
  [sensor_index]              => string(1) "1"
  [sensor_type]               => string(32) "EPPC-MIB-upsESystemOutputVoltage"
  [sensor_descr]              => string(6) "Output"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(5) "264.5"
  [sensor_limit_warn]         => string(3) "253"
  [sensor_limit_low]          => string(5) "195.5"
  [sensor_limit_low_warn]     => string(3) "207"
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(18) "0.0000000000000000"
  [sensor_event]              => string(5) "alert"
  [sensor_status]             => string(36) "Sensor critical thresholds exceeded."
  [sensor_polled]             => string(10) "1676297541"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.3.]

CMD EXITCODE[1]
CMD RUNTIME[0.0168s]
STDOUT[

]
STDERR[
.1.3.6.1.4.1.935.10.1.1.2.18.1.3.: Unknown Object Identifier ()
]
SNMP STATUS[FALSE]
SNMP ERROR[#996 - MIB or oid not found]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => string(0) ""
)
RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemOutputVoltage-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemOutputVoltage-1.rrd N:]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.41]
RRD_STATUS[TRUE]

Checking (snmp) voltage Battery 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2450"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "voltage"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(29) ".1.3.6.1.4.1.935.10.1.1.3.5.0"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(26) "upsEPositiveBatteryVoltage"
  [sensor_index]              => string(1) "0"
  [sensor_type]               => string(35) "EPPC-MIB-upsEPositiveBatteryVoltage"
  [sensor_descr]              => string(7) "Battery"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(5) "93.61"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(5) "69.19"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(19) "81.4000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297541"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.5.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0239s]
STDOUT[
814
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(814)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsEPositiveBatteryVoltage-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsEPositiveBatteryVoltage-0.rrd N:81.4]
RRD RUNTIME[0.0012s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.44]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00070119s]
Checking (snmp) capacity Battery Charge Remaining 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2451"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(8) "capacity"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(29) ".1.3.6.1.4.1.935.10.1.1.3.4.0"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(35) "upsEBatteryEstimatedChargeRemaining"
  [sensor_index]              => string(1) "0"
  [sensor_type]               => string(44) "EPPC-MIB-upsEBatteryEstimatedChargeRemaining"
  [sensor_descr]              => string(24) "Battery Charge Remaining"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => null
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(2) "10"
  [sensor_limit_low_warn]     => string(2) "20"
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(20) "100.0000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297541"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.4.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0249s]
STDOUT[
100
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(100)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-capacity-EPPC-MIB-upsEBatteryEstimatedChargeRemaining-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-capacity-EPPC-MIB-upsEBatteryEstimatedChargeRemaining-0.rrd N:100]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.47]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00064898s]
Checking (snmp) runtime Battery Runtime 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2453"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "runtime"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(29) ".1.3.6.1.4.1.935.10.1.1.3.2.0"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(20) "upsESecondsOnBattery"
  [sensor_index]              => string(1) "0"
  [sensor_type]               => string(29) "EPPC-MIB-upsESecondsOnBattery"
  [sensor_descr]              => string(15) "Battery Runtime"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(9) "0.0166667"
  [sensor_limit]              => null
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => null
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(18) "0.0000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297542"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.2.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0238s]
STDOUT[
0
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(0)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsESecondsOnBattery-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsESecondsOnBattery-0.rrd N:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.50]
RRD_STATUS[TRUE]

Checking (snmp) runtime Battery Runtime Remaining 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2452"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "runtime"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(29) ".1.3.6.1.4.1.935.10.1.1.3.3.0"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(36) "upsEBatteryEstimatedMinutesRemaining"
  [sensor_index]              => string(1) "0"
  [sensor_type]               => string(45) "EPPC-MIB-upsEBatteryEstimatedMinutesRemaining"
  [sensor_descr]              => string(25) "Battery Runtime Remaining"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => null
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "5"
  [sensor_limit_low_warn]     => string(2) "20"
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(20) "294.0000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297542"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.3.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0242s]
STDOUT[
292
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(292)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsEBatteryEstimatedMinutesRemaining-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsEBatteryEstimatedMinutesRemaining-0.rrd N:292]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.53]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00077891s]
Checking (snmp) frequency Input 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2455"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(9) "frequency"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) ".1.3.6.1.4.1.935.10.1.1.2.16.1.2.1"
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(24) "upsESystemInputFrequency"
  [sensor_index]              => string(1) "1"
  [sensor_type]               => string(33) "EPPC-MIB-upsESystemInputFrequency"
  [sensor_descr]              => string(5) "Input"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(6) "-0.095"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(6) "-0.105"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(19) "-0.1000000000000000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1676297542"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1]

CMD EXITCODE[0]
CMD RUNTIME[0.0239s]
STDOUT[
-1
]
SNMP STATUS[TRUE]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => int(-1)
)
RRD /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemInputFrequency-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemInputFrequency-1.rrd N:-0.1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.55]
RRD_STATUS[TRUE]

Checking (snmp) frequency Output 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2457"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(9) "frequency"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.2."
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(25) "upsESystemOutputFrequency"
  [sensor_index]              => string(1) "1"
  [sensor_type]               => string(34) "EPPC-MIB-upsESystemOutputFrequency"
  [sensor_descr]              => string(6) "Output"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(3) "0.1"
  [sensor_limit]              => string(4) "52.5"
  [sensor_limit_warn]         => string(4) "51.5"
  [sensor_limit_low]          => string(4) "47.5"
  [sensor_limit_low_warn]     => string(4) "48.5"
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(18) "0.0000000000000000"
  [sensor_event]              => string(5) "alert"
  [sensor_status]             => string(36) "Sensor critical thresholds exceeded."
  [sensor_polled]             => string(10) "1676297542"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.2.]

CMD EXITCODE[1]
CMD RUNTIME[0.0204s]
STDOUT[

]
STDERR[
.1.3.6.1.4.1.935.10.1.1.2.18.1.2.: Unknown Object Identifier ()
]
SNMP STATUS[FALSE]
SNMP ERROR[#996 - MIB or oid not found]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => string(0) ""
)
RRD /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemOutputFrequency-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemOutputFrequency-1.rrd N:]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.58]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00113392s]
Checking (snmp) load Output 

  /opt/observium/includes/entities/sensor.inc.php:781 
array(
  [sensor_id]                 => string(4) "2458"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(4) "load"
  [device_id]                 => string(3) "169"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.7."
  [sensor_mib]                => string(8) "EPPC-MIB"
  [sensor_object]             => string(20) "upsESystemOutputLoad"
  [sensor_index]              => string(1) "1"
  [sensor_type]               => string(29) "EPPC-MIB-upsESystemOutputLoad"
  [sensor_descr]              => string(6) "Output"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => string(2) "90"
  [sensor_limit_warn]         => string(2) "75"
  [sensor_limit_low]          => null
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [measured_entity_label]     => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(18) "0.0000000000000000"
  [sensor_event]              => string(5) "alert"
  [sensor_status]             => string(36) "Sensor critical thresholds exceeded."
  [sensor_polled]             => string(10) "1676297542"
  [sensor_last_change]        => string(10) "1676285543"
)

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.7.]

CMD EXITCODE[1]
CMD RUNTIME[0.017s]
STDOUT[

]
STDERR[
.1.3.6.1.4.1.935.10.1.1.2.18.1.7.: Unknown Object Identifier ()
]
SNMP STATUS[FALSE]
SNMP ERROR[#996 - MIB or oid not found]


  /opt/observium/includes/entities/sensor.inc.php:856 
array(
  [sensor_value] => string(0) ""
)
RRD /opt/observium/rrd/172.21.99.138/sensor-load-EPPC-MIB-upsESystemOutputLoad-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-load-EPPC-MIB-upsESystemOutputLoad-1.rrd N:]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.60]
RRD_STATUS[TRUE]

MultiUpdate sensors DB.

SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`) VALUES ('2449','23.3','ok','','1676285543','1676297743'),('2454','232.8','ok','','1676285543','1676297744'),('2456','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744'),('2450','81.4','ok','','1676285543','1676297744'),('2451','100','ok','','1676285543','1676297744'),('2453','0','ok','','1676285543','1676297744'),('2452','292','ok','','1676285543','1676297744'),('2455','-0.1','ok','','1676285543','1676297744'),('2457','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744'),('2458','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)]
SQL RUNTIME[0.00289488s]
+---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+
| Descr                     | Class       | Type                                          | Origin | Value      | Event | Last Changed        |
+---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+
| System                    | temperature | EPPC-MIB-upsESystemTemperature                | snmp   | 23.3&deg;C | ok    | 2023-02-13 11:52:23 |
| Input                     | voltage     | EPPC-MIB-upsESystemInputVoltage               | snmp   | 232.8V     | ok    | 2023-02-13 11:52:23 |
| Output                    | voltage     | EPPC-MIB-upsESystemOutputVoltage              | snmp   | V          | alert | 2023-02-13 11:52:23 |
| Battery                   | voltage     | EPPC-MIB-upsEPositiveBatteryVoltage           | snmp   | 81.4V      | ok    | 2023-02-13 11:52:23 |
| Battery Charge Remaining  | capacity    | EPPC-MIB-upsEBatteryEstimatedChargeRemaining  | snmp   | 100%       | ok    | 2023-02-13 11:52:23 |
| Battery Runtime           | runtime     | EPPC-MIB-upsESecondsOnBattery                 | snmp   | 0min       | ok    | 2023-02-13 11:52:23 |
| Battery Runtime Remaining | runtime     | EPPC-MIB-upsEBatteryEstimatedMinutesRemaining | snmp   | 292min     | ok    | 2023-02-13 11:52:23 |
| Input                     | frequency   | EPPC-MIB-upsESystemInputFrequency             | snmp   | -0.1Hz     | ok    | 2023-02-13 11:52:23 |
| Output                    | frequency   | EPPC-MIB-upsESystemOutputFrequency            | snmp   | Hz         | alert | 2023-02-13 11:52:23 |
| Output                    | load        | EPPC-MIB-upsESystemOutputLoad                 | snmp   | %          | alert | 2023-02-13 11:52:23 |
+---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+

 o Module time          0.3201s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-sensors.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-sensors.rrd N:0.3201]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.63]
RRD_STATUS[TRUE]



including: includes/polling/status.inc.php
#####  Module Start: status  #####


SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0';]
SQL RUNTIME[0.00053811s]
 o Status Count         2

SQL[SELECT DISTINCT `status_oid` FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0' AND `poller_type` = 'snmp']
SQL RUNTIME[0.00034213s]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.1.0 .1.3.6.1.4.1.935.10.1.1.3.1.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0274s]
STDOUT[
.1.3.6.1.4.1.935.10.1.1.2.1.0 = 4
.1.3.6.1.4.1.935.10.1.1.3.1.0 = 2
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0' ORDER BY `status_oid`]
SQL RUNTIME[0.00068188s]
Checking (snmp) System Status 
value taken from oid_cache
RRD /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsESystemStatus-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsESystemStatus-0.rrd N:4]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.66]
RRD_STATUS[TRUE]

Checking (snmp) Battery Status 
value taken from oid_cache
RRD /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsEBatteryStatus-0.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsEBatteryStatus-0.rrd N:2]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.66]
RRD_STATUS[TRUE]

MultiUpdate status DB.

SQL[INSERT INTO `status` (`status_id`,`status_value`,`status_name`,`status_event`,`status_last_change`,`status_polled`) VALUES ('820','4','line','ok','1676285543','1676297744'),('821','2','batteryNormal','ok','1676285543','1676297744') ON DUPLICATE KEY UPDATE `status_id`=VALUES(`status_id`),`status_value`=VALUES(`status_value`),`status_name`=VALUES(`status_name`),`status_event`=VALUES(`status_event`),`status_last_change`=VALUES(`status_last_change`),`status_polled`=VALUES(`status_polled`)]
SQL RUNTIME[0.00205898s]
+----------------+-------------------+-------+--------+---------------+--------+---------------------+
| Descr          | Type              | Index | Origin | Value         | Status | Last Changed        |
+----------------+-------------------+-------+--------+---------------+--------+---------------------+
| System Status  | upsESystemStatus  | 0     | snmp   | line          | ok     | 2023-02-13 11:52:23 |
| Battery Status | upsEBatteryStatus | 0     | snmp   | batteryNormal | ok     | 2023-02-13 11:52:23 |
+----------------+-------------------+-------+--------+---------------+--------+---------------------+

 o Module time          0.0423s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-status.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-status.rrd N:0.0423]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.67]
RRD_STATUS[TRUE]



including: includes/polling/counter.inc.php
#####  Module Start: counter  #####


SQL[SELECT EXISTS (SELECT 1 FROM `counters` WHERE `device_id` = '169' AND `counter_deleted` = '0')]
SQL RUNTIME[0.00035501s]
 o Module time          0.0014s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-counter.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-counter.rrd N:0.0014]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.67]
RRD_STATUS[TRUE]



including: includes/polling/processors.inc.php
#####  Module Start: processors  #####


SQL[SELECT `processor_oid` FROM `processors` WHERE `device_id` = '169' AND `processor_oid` REGEXP '^\\.?[0-9]+(\\.[0-9]+)+$' AND `processor_type` != 'wmi']
SQL RUNTIME[0.00025296s]

SQL[SELECT * FROM `processors` WHERE `device_id` = '169']
SQL RUNTIME[0.00027204s]
 o Module time          0.0019s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-processors.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-processors.rrd N:0.0019]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.68]
RRD_STATUS[TRUE]



including: includes/polling/mempools.inc.php
#####  Module Start: mempools  #####


SQL[SELECT * FROM `mempools` WHERE `device_id` = '169']
SQL RUNTIME[0.00024605s]
 o Module time          0.0012s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-mempools.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-mempools.rrd N:0.0012]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.68]
RRD_STATUS[TRUE]



including: includes/polling/storage.inc.php
#####  Module Start: storage  #####


SQL[SELECT `storage_mib`, `storage_object`, `storage_hc`, GROUP_CONCAT(`storage_index` SEPARATOR ',') AS `indexes` FROM `storage` WHERE `device_id` = '169' GROUP BY `storage_mib`, `storage_object`, `storage_hc`]
SQL RUNTIME[0.00034308s]

SQL[SELECT * FROM `storage` WHERE `device_id` = '169']
SQL RUNTIME[0.00025201s]
 o Module time          0.0021s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-storage.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-storage.rrd N:0.0021]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.68]
RRD_STATUS[TRUE]



including: includes/polling/ucd-mib.inc.php
#####  Module Start: ucd-mib  #####


CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' systemStats]

CMD EXITCODE[0]
CMD RUNTIME[0.0397s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0]

CMD EXITCODE[2]
CMD RUNTIME[0.1244s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memTotalSwap.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memAvailSwap.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memTotalReal.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memAvailReal.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memTotalFree.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memShared.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memBuffer.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memCached.0
]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = 'memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0';]
SQL RUNTIME[0.00043797s]

SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297744' WHERE `error_id` = '3281']
SQL RUNTIME[0.00238490s]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = 'memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0';]
SQL RUNTIME[0.00031996s]

SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297744' WHERE `error_id` = '3281']
SQL RUNTIME[0.00150013s]
SNMP STATUS[FALSE]
 o Module time          0.1763s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-mib.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-mib.rrd N:0.1763]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:0.86]
RRD_STATUS[TRUE]



including: includes/polling/ipSystemStats.inc.php
#####  Module Start: ipSystemStats  #####

 o Collecting           ipSystemStats

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipSystemStats]

CMD EXITCODE[0]
CMD RUNTIME[1.044s]
STDOUT[
ipSystemStatsInReceives.ipv4 = 0
ipSystemStatsInReceives.ipv6 = 123
ipSystemStatsHCInReceives.ipv4 = 0
ipSystemStatsHCInReceives.ipv6 = 123
ipSystemStatsInOctets.ipv4 = 7446625
ipSystemStatsInOctets.ipv6 = 0
ipSystemStatsHCInOctets.ipv4 = 7446811
ipSystemStatsHCInOctets.ipv6 = 0
ipSystemStatsInHdrErrors.ipv4 = 0
ipSystemStatsInHdrErrors.ipv6 = 0
ipSystemStatsInNoRoutes.ipv4 = 0
ipSystemStatsInNoRoutes.ipv6 = 0
ipSystemStatsInAddrErrors.ipv4 = 0
ipSystemStatsInAddrErrors.ipv6 = 0
ipSystemStatsInUnknownProtos.ipv4 = 187
ipSystemStatsInUnknownProtos.ipv6 = 0
ipSystemStatsInTruncatedPkts.ipv4 = 0
ipSystemStatsInTruncatedPkts.ipv6 = 0
ipSystemStatsInForwDatagrams.ipv4 = 0
ipSystemStatsInForwDatagrams.ipv6 = 0
ipSystemStatsHCInForwDatagrams.ipv4 = 0
ipSystemStatsHCInForwDatagrams.ipv6 = 0
ipSystemStatsReasmReqds.ipv4 = 0
ipSystemStatsReasmReqds.ipv6 = 0
ipSystemStatsReasmOKs.ipv4 = 0
ipSystemStatsReasmOKs.ipv6 = 0
ipSystemStatsReasmFails.ipv4 = 0
ipSystemStatsReasmFails.ipv6 = 0
ipSystemStatsInDiscards.ipv4 = 0
ipSystemStatsInDiscards.ipv6 = 5
ipSystemStatsInDelivers.ipv4 = 0
ipSystemStatsInDelivers.ipv6 = 12
ipSystemStatsHCInDelivers.ipv4 = 0
ipSystemStatsHCInDelivers.ipv6 = 0
ipSystemStatsOutRequests.ipv4 = 0
ipSystemStatsOutRequests.ipv6 = 0
ipSystemStatsHCOutRequests.ipv4 = 0
ipSystemStatsHCOutRequests.ipv6 = 0
ipSystemStatsOutNoRoutes.ipv4 = 0
ipSystemStatsOutNoRoutes.ipv6 = 0
ipSystemStatsOutForwDatagrams.ipv4 = 0
ipSystemStatsOutForwDatagrams.ipv6 = 0
ipSystemStatsHCOutForwDatagrams.ipv4 = 0
ipSystemStatsHCOutForwDatagrams.ipv6 = 0
ipSystemStatsOutDiscards.ipv4 = 0
ipSystemStatsOutDiscards.ipv6 = 0
ipSystemStatsOutFragReqds.ipv4 = 0
ipSystemStatsOutFragReqds.ipv6 = 0
ipSystemStatsOutFragOKs.ipv4 = 0
ipSystemStatsOutFragOKs.ipv6 = 0
ipSystemStatsOutFragFails.ipv4 = 3869252
ipSystemStatsOutFragFails.ipv6 = 0
ipSystemStatsOutFragCreates.ipv4 = 3869434
ipSystemStatsOutFragCreates.ipv6 = 0
ipSystemStatsOutTransmits.ipv4 = 551
ipSystemStatsOutTransmits.ipv6 = 0
ipSystemStatsHCOutTransmits.ipv4 = 551
ipSystemStatsHCOutTransmits.ipv6 = 0
ipSystemStatsOutOctets.ipv4 = 0
ipSystemStatsOutOctets.ipv6 = 0
ipSystemStatsHCOutOctets.ipv4 = 0
ipSystemStatsHCOutOctets.ipv6 = 0
ipSystemStatsInMcastPkts.ipv4 = 2
ipSystemStatsInMcastPkts.ipv6 = 7
ipSystemStatsHCInMcastPkts.ipv4 = 2
ipSystemStatsHCInMcastPkts.ipv6 = 7
ipSystemStatsInMcastOctets.ipv4 = 0
ipSystemStatsInMcastOctets.ipv6 = 0
ipSystemStatsHCInMcastOctets.ipv4 = 0
ipSystemStatsHCInMcastOctets.ipv6 = 0
ipSystemStatsOutMcastPkts.ipv4 = 24531
ipSystemStatsOutMcastPkts.ipv6 = 0
ipSystemStatsHCOutMcastPkts.ipv4 = 24531
ipSystemStatsHCOutMcastPkts.ipv6 = 0
ipSystemStatsOutMcastOctets.ipv4 = 7
ipSystemStatsOutMcastOctets.ipv6 = 0
ipSystemStatsHCOutMcastOctets.ipv4 = 7
ipSystemStatsHCOutMcastOctets.ipv6 = 0
ipSystemStatsInBcastPkts.ipv4 = 0:0:00:00.00
ipSystemStatsInBcastPkts.ipv6 = 0:0:00:00.00
ipSystemStatsHCInBcastPkts.ipv4 = 0
ipSystemStatsHCInBcastPkts.ipv6 = 0
]
SNMP STATUS[TRUE]
 o Address Families      ipv4RRD /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv4.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv4.rrd N:0:0:0:187:0:0:0:0:0:0:0:0:0:3869252:3869434:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:1.91]
RRD_STATUS[TRUE]

 ipv6RRD /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv6.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv6.rrd N:123:0:0:0:0:0:0:0:5:0:0:0:0:0:0:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:1.91]
RRD_STATUS[TRUE]


 o Graphs               ipsystemstats_ipv4 ipsystemstats_ipv4_frag ipsystemstats_ipv6 ipsystemstats_ipv6_frag
 o Module time          1.0497s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ipSystemStats.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ipSystemStats.rrd N:1.0497]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:1.91]
RRD_STATUS[TRUE]



including: includes/polling/ports.inc.php
#####  Module Start: ports  #####


SQL[SELECT * FROM `ports` WHERE `device_id` = '169']
SQL RUNTIME[0.00066209s]

SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '169' AND `entity_type` = 'port']
SQL RUNTIME[0.00033617s]
Module [ports_etherlike] disabled globally by config in process [poller].
Module [ports_junoseatmvp] excluded for device os in process [poller].
Module [ports_fdbcount] disabled globally by config in process [poller].
Module [ports_separate_walk] disabled globally by config in process [poller].
 o Caching Oids         Used full table ifEntry/ifXEntry snmpwalk.
ifEntry Added Oid END 'ifOutQLen' for snmpwalk 'ifEntry'.

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -CE 'ifOutQLen' -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.4176s]
STDOUT[
ifIndex.1 = 1
ifIndex.2 = 2
ifDescr.1 = lo
ifDescr.2 = eth0
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd
ifMtu.1 = 1500
ifMtu.2 = 1500
ifSpeed.1 = 0
ifSpeed.2 = 10000000
ifPhysAddress.1 = 
ifPhysAddress.2 = 0:20:85:e5:a6:86
ifAdminStatus.1 = up
ifAdminStatus.2 = up
ifOperStatus.1 = up
ifOperStatus.2 = up
ifLastChange.1 = 0:0:00:00.00
ifLastChange.2 = 0:0:00:08.67
ifInOctets.1 = 1656158
ifInOctets.2 = 5799751
ifInUcastPkts.1 = 7111
ifInUcastPkts.2 = 12011
ifInNUcastPkts.1 = 0
ifInNUcastPkts.2 = 25083
ifInDiscards.1 = 0
ifInDiscards.2 = 0
ifInErrors.1 = 0
ifInErrors.2 = 0
ifInUnknownProtos.1 = 0
ifInUnknownProtos.2 = 187
ifOutOctets.1 = 1656158
ifOutOctets.2 = 2218856
ifOutUcastPkts.1 = 7111
ifOutUcastPkts.2 = 11325
ifOutNUcastPkts.1 = 0
ifOutNUcastPkts.2 = 9
ifOutDiscards.1 = 0
ifOutDiscards.2 = 0
ifOutErrors.1 = 0
ifOutErrors.2 = 0
]
SNMP STATUS[TRUE]
ifXEntry Added Oid END 'ifCounterDiscontinuityTime' for snmpwalk 'ifXEntry'.

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -CE 'ifCounterDiscontinuityTime' -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifXEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0332s]
STDOUT[

]
SNMP STATUS[TRUE]

 o ADSL-LINE-MIB        
SQL[SELECT EXISTS (SELECT 1 FROM `ports` WHERE `device_id` = '169' AND `ifType` IN ('adsl', 'vdsl', 'vdsl2'))]
SQL RUNTIME[0.00064397s]

 o EtherLike-MIB        dot3StatsDuplexStatus 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EtherLike-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot3StatsDuplexStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0371s]
STDOUT[

]
SNMP STATUS[TRUE]

 o Q-BRIDGE-MIB         
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1dBasePortIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0373s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qPvid]

CMD EXITCODE[0]
CMD RUNTIME[0.066s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qVlanStaticUntaggedPorts]

CMD EXITCODE[0]
CMD RUNTIME[0.0503s]
STDOUT[

]
SNMP STATUS[TRUE]
dot1qVlanStaticUntaggedPorts print_cli_table() argument  should be an array. Please report this error to developers.

[[IP-MIB]] o IP-MIB               IP-MIB ipIfStats 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsX -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipIfStatsHCInOctets]

CMD EXITCODE[0]
CMD RUNTIME[0.0719s]
STDOUT[
ipIfStatsHCInOctets[ipv4][1] = 1656158
ipIfStatsHCInOctets[ipv4][2] = 5802923
ipIfStatsHCInOctets[ipv6][1] = 0
ipIfStatsHCInOctets[ipv6][2] = 0
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsX -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipIfStatsHCOutOctets]

CMD EXITCODE[0]
CMD RUNTIME[0.0847s]
STDOUT[
ipIfStatsHCOutOctets[ipv4][1] = 0
ipIfStatsHCOutOctets[ipv4][2] = 0
ipIfStatsHCOutOctets[ipv6][1] = 0
ipIfStatsHCOutOctets[ipv6][2] = 0
]
SNMP STATUS[TRUE]




SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7725']
SQL RUNTIME[0.00044107s]

SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '169']
SQL RUNTIME[0.00033021s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725']
SQL RUNTIME[0.00030494s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '169']
SQL RUNTIME[0.00035214s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169']
SQL RUNTIME[0.00031996s]
RRD /opt/observium/rrd/172.21.99.138/port-1-ipv6-octets.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/port-1-ipv6-octets.rrd N:0:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.74]
RRD_STATUS[TRUE]


SQL[SELECT EXISTS (SELECT 1 FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725' AND `attrib_type` = 'ipv6-octets')]
SQL RUNTIME[0.00032401s]

SQL[UPDATE `entity_attribs` set `attrib_value` ='1' WHERE `entity_type` = 'port' AND `entity_id` = '7725' AND `attrib_type` = 'ipv6-octets']
SQL RUNTIME[0.00028610s]
Timeticks converted 0:0:00:00.00 -> 0
IFLASTCHANGE = 1676297744s - 5571s + 0s
BC SUB: 1656158 - 1656158 = 0

 ifInOctets (0 B) 0 Bps 203 secs
BC SUB: 1656158 - 1656158 = 0

 ifOutOctets (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifInErrors (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifOutErrors (0 B) 0 Bps 203 secs
BC SUB: 7111 - 7111 = 0

 ifInUcastPkts (0 B) 0 Bps 203 secs
BC SUB: 7111 - 7111 = 0

 ifOutUcastPkts (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifInNUcastPkts (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifOutNUcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifInBroadcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifOutBroadcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifInMulticastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifOutMulticastPkts (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifInDiscards (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifOutDiscards (0 B) 0 Bps 203 secs
RRD /opt/observium/rrd/172.21.99.138/port-1.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/port-1.rrd N:1656158:1656158:0:0:7111:7111:0:0:0:0:0:U:U:U:U]
RRD RUNTIME[0.0013s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.75]
RRD_STATUS[TRUE]

Checking alert 3 associated by 

Testing: ifInOctets_perc > 80
 (value: 0)
NOT TRUE
%G[OK]%N
Testing: ifOutOctets_perc > 80
 (value: 0)
NOT TRUE
%G[OK]%N
RRD /opt/observium/rrd/172.21.99.138/alert-3-port-7725.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-3-port-7725.rrd N:1:1]
RRD RUNTIME[0.0012s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.75]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7726']
SQL RUNTIME[0.00035787s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726']
SQL RUNTIME[0.00055504s]
RRD /opt/observium/rrd/172.21.99.138/port-2-ipv6-octets.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/port-2-ipv6-octets.rrd N:0:0]
RRD RUNTIME[0.0012s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.75]
RRD_STATUS[TRUE]


SQL[SELECT EXISTS (SELECT 1 FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726' AND `attrib_type` = 'ipv6-octets')]
SQL RUNTIME[0.00030708s]

SQL[UPDATE `entity_attribs` set `attrib_value` ='1' WHERE `entity_type` = 'port' AND `entity_id` = '7726' AND `attrib_type` = 'ipv6-octets']
SQL RUNTIME[0.00027919s]
Timeticks converted 0:0:00:08.67 -> 8
IFLASTCHANGE = 1676297744s - 5571s + 8s
BC SUB: 5799751 - 5615350 = 184401

 ifInOctets (184401 B) 908.37931034483 Bps 203 secs
BC SUB: 2218856 - 2157316 = 61540

 ifOutOctets (61540 B) 303.15270935961 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifInErrors (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifOutErrors (0 B) 0 Bps 203 secs
BC SUB: 12011 - 11685 = 326

 ifInUcastPkts (326 B) 1.6059113300493 Bps 203 secs
BC SUB: 11325 - 11005 = 320

 ifOutUcastPkts (320 B) 1.576354679803 Bps 203 secs
BC SUB: 25083 - 24176 = 907

 ifInNUcastPkts (907 B) 4.4679802955665 Bps 203 secs
BC SUB: 9 - 9 = 0

 ifOutNUcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifInBroadcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifOutBroadcastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifInMulticastPkts (0 B) 0 Bps 203 secs
BC SUB:  - 0 = 0

 ifOutMulticastPkts (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifInDiscards (0 B) 0 Bps 203 secs
BC SUB: 0 - 0 = 0

 ifOutDiscards (0 B) 0 Bps 203 secs
RRD /opt/observium/rrd/172.21.99.138/port-2.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/port-2.rrd N:5799751:2218856:0:0:12011:11325:25083:9:0:0:187:U:U:U:U]
RRD RUNTIME[0.0012s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.76]
RRD_STATUS[TRUE]

Checking alert 3 associated by 

Testing: ifInOctets_perc > 80
 (value: 0)
NOT TRUE
%G[OK]%N
Testing: ifOutOctets_perc > 80
 (value: 0)
NOT TRUE
%G[OK]%N
RRD /opt/observium/rrd/172.21.99.138/alert-3-port-7726.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-3-port-7726.rrd N:1:1]
RRD RUNTIME[0.0012s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.76]
RRD_STATUS[TRUE]

MultiUpdate ports states DB.

SQL[INSERT INTO `ports` (`port_id`,`ifIndex`,`device_id`,`poll_time`,`poll_period`,`ifInOctets`,`ifInOctets_rate`,`ifOutOctets`,`ifOutOctets_rate`,`ifInErrors`,`ifInErrors_rate`,`ifInErrors_delta`,`ifOutErrors`,`ifOutErrors_rate`,`ifOutErrors_delta`,`ifInUcastPkts`,`ifInUcastPkts_rate`,`ifOutUcastPkts`,`ifOutUcastPkts_rate`,`ifInNUcastPkts`,`ifInNUcastPkts_rate`,`ifOutNUcastPkts`,`ifOutNUcastPkts_rate`,`ifInBroadcastPkts`,`ifInBroadcastPkts_rate`,`ifOutBroadcastPkts`,`ifOutBroadcastPkts_rate`,`ifInMulticastPkts`,`ifInMulticastPkts_rate`,`ifOutMulticastPkts`,`ifOutMulticastPkts_rate`,`ifInDiscards`,`ifInDiscards_rate`,`ifOutDiscards`,`ifOutDiscards_rate`,`ifInOctets_perc`,`ifOutOctets_perc`,`ifOctets_rate`,`ifUcastPkts_rate`,`ifErrors_rate`,`ifDiscards_rate`) VALUES ('7725','1','169','1676297746','203','1656158','0','1656158','0','0','0','0','0','0','0','7111','0','7111','0','0','0','0','0','','0','','0','','0','','0','0','0','0','0','0','0','0','0','0','0'),('7726','2','169','1676297746','203','5799751','908.37931034483','2218856','303.15270935961','0','0','0','0','0','0','12011','1.6059113300493','11325','1.576354679803','25083','4.4679802955665','9','0','','0','','0','','0','','0','0','0','0','0','0','0','1211.5320197044','3.1822660098522','0','0') ON DUPLICATE KEY UPDATE `port_id`=VALUES(`port_id`),`ifIndex`=VALUES(`ifIndex`),`device_id`=VALUES(`device_id`),`poll_time`=VALUES(`poll_time`),`poll_period`=VALUES(`poll_period`),`ifInOctets`=VALUES(`ifInOctets`),`ifInOctets_rate`=VALUES(`ifInOctets_rate`),`ifOutOctets`=VALUES(`ifOutOctets`),`ifOutOctets_rate`=VALUES(`ifOutOctets_rate`),`ifInErrors`=VALUES(`ifInErrors`),`ifInErrors_rate`=VALUES(`ifInErrors_rate`),`ifInErrors_delta`=VALUES(`ifInErrors_delta`),`ifOutErrors`=VALUES(`ifOutErrors`),`ifOutErrors_rate`=VALUES(`ifOutErrors_rate`),`ifOutErrors_delta`=VALUES(`ifOutErrors_delta`),`ifInUcastPkts`=VALUES(`ifInUcastPkts`),`ifInUcastPkts_rate`=VALUES(`ifInUcastPkts_rate`),`ifOutUcastPkts`=VALUES(`ifOutUcastPkts`),`ifOutUcastPkts_rate`=VALUES(`ifOutUcastPkts_rate`),`ifInNUcastPkts`=VALUES(`ifInNUcastPkts`),`ifInNUcastPkts_rate`=VALUES(`ifInNUcastPkts_rate`),`ifOutNUcastPkts`=VALUES(`ifOutNUcastPkts`),`ifOutNUcastPkts_rate`=VALUES(`ifOutNUcastPkts_rate`),`ifInBroadcastPkts`=VALUES(`ifInBroadcastPkts`),`ifInBroadcastPkts_rate`=VALUES(`ifInBroadcastPkts_rate`),`ifOutBroadcastPkts`=VALUES(`ifOutBroadcastPkts`),`ifOutBroadcastPkts_rate`=VALUES(`ifOutBroadcastPkts_rate`),`ifInMulticastPkts`=VALUES(`ifInMulticastPkts`),`ifInMulticastPkts_rate`=VALUES(`ifInMulticastPkts_rate`),`ifOutMulticastPkts`=VALUES(`ifOutMulticastPkts`),`ifOutMulticastPkts_rate`=VALUES(`ifOutMulticastPkts_rate`),`ifInDiscards`=VALUES(`ifInDiscards`),`ifInDiscards_rate`=VALUES(`ifInDiscards_rate`),`ifOutDiscards`=VALUES(`ifOutDiscards`),`ifOutDiscards_rate`=VALUES(`ifOutDiscards_rate`),`ifInOctets_perc`=VALUES(`ifInOctets_perc`),`ifOutOctets_perc`=VALUES(`ifOutOctets_perc`),`ifOctets_rate`=VALUES(`ifOctets_rate`),`ifUcastPkts_rate`=VALUES(`ifUcastPkts_rate`),`ifErrors_rate`=VALUES(`ifErrors_rate`),`ifDiscards_rate`=VALUES(`ifDiscards_rate`)]
SQL RUNTIME[0.00250697s]
+---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+
| ifIndex | Label | Type     | Speed  | BPS In   | BPS Out  | Data In | Data Out | PPS In | PPS Out | HC |
+---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+
| 1       | lo    | Loopback | 0bps   | 0bps     | 0bps     | 0B      | 0B       | 0      | 0       | N  |
| 2       | eth0  | Ethernet | 10Mbps | 7.27kbps | 2.43kbps | 180kB   | 60.1kB   | 1.61   | 1.58    | N  |
+---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+


 o Module time          0.8569s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ports.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ports.rrd N:0.8569]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.77]
RRD_STATUS[TRUE]



including: includes/polling/printersupplies.inc.php
#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '169']
SQL RUNTIME[0.00026798s]
 o Module time          0.0010s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-printersupplies.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-printersupplies.rrd N:0.001]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.77]
RRD_STATUS[TRUE]



including: includes/polling/ucd-diskio.inc.php
#####  Module Start: ucd-diskio  #####


SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '169']
SQL RUNTIME[0.00024009s]
 o Module time          0.0009s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-diskio.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-diskio.rrd N:0.0009]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.77]
RRD_STATUS[TRUE]



including: includes/polling/ospf.inc.php
#####  Module Start: ospf  #####

 o Module time          0.0001s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ospf.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ospf.rrd N:0.0001]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.78]
RRD_STATUS[TRUE]



including: includes/polling/sla.inc.php
#####  Module Start: sla  #####


SQL[SELECT * FROM `slas` WHERE `device_id` = '169' AND `deleted` = 0;]
SQL RUNTIME[0.00028610s]
 o MIBs                 
 o Module time          0.0013s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-sla.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-sla.rrd N:0.0013]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.78]
RRD_STATUS[TRUE]



including: includes/polling/mac-accounting.inc.php
#####  Module Start: mac-accounting  #####

 o MIBs                 
SQL[SELECT * FROM `mac_accounting` WHERE `device_id` = '169']
SQL RUNTIME[0.00032496s]

 o Module time          0.0014s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-mac-accounting.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-mac-accounting.rrd N:0.0014]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.78]
RRD_STATUS[TRUE]



including: includes/polling/loadbalancer.inc.php
#####  Module Start: loadbalancer  #####

 o Module time          0.0004s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-loadbalancer.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-loadbalancer.rrd N:0.0004]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.78]
RRD_STATUS[TRUE]



including: includes/polling/entity-physical.inc.php
#####  Module Start: entity-physical  #####

 o Module time          0.0002s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-entity-physical.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-entity-physical.rrd N:0.0002]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.78]
RRD_STATUS[TRUE]



including: includes/polling/applications.inc.php
#####  Module Start: applications  #####


SQL[SELECT * FROM `applications` WHERE `device_id` = '169']
SQL RUNTIME[0.00024796s]

SQL[SELECT * FROM `applications` WHERE `device_id` = '169' AND `app_lastpolled` < '1675692946']
SQL RUNTIME[0.00023079s]
 o Module time          0.0016s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-applications.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-applications.rrd N:0.0016]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.79]
RRD_STATUS[TRUE]



including: includes/polling/fdb-table.inc.php
#####  Module Start: fdb-table  #####


SQL[SELECT `ifIndex`,`port_id`,`ifDescr`,`port_label_short` FROM `ports` WHERE `device_id` = '169']
SQL RUNTIME[0.00027704s]

SQL[SELECT * FROM `vlans_fdb` WHERE `device_id` = '169']
SQL RUNTIME[0.00024796s]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qTpFdbEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0439s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1dBasePortIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0338s]
STDOUT[

]
SNMP STATUS[TRUE]
Module [ports_fdbcount] disabled globally by config in process [poller].
 o Module time          0.0842s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-fdb-table.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-fdb-table.rrd N:0.0842]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.87]
RRD_STATUS[TRUE]



including: includes/polling/graphs.inc.php
#####  Module Start: graphs  #####

 o HOST-RESOURCES-MIB   
 o HOST-RESOURCES-MIB   hrSystemProcesses 
SQL[SELECT `object` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'oid' AND `disabled` = '1' AND `mib` = 'HOST-RESOURCES-MIB']
SQL RUNTIME[0.00037885s]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrSystemProcesses.0]

CMD EXITCODE[2]
CMD RUNTIME[0.0254s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: hrSystemProcesses.0
]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemProcesses.0';]
SQL RUNTIME[0.00046301s]

SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297746' WHERE `error_id` = '3282']
SQL RUNTIME[0.02854204s]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemProcesses.0';]
SQL RUNTIME[0.00039005s]

SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297746' WHERE `error_id` = '3282']
SQL RUNTIME[0.00169086s]
SNMP STATUS[FALSE]
  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped.
hrSystemNumUsers 
CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrSystemNumUsers.0]

CMD EXITCODE[2]
CMD RUNTIME[0.0256s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: hrSystemNumUsers.0
]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemNumUsers.0';]
SQL RUNTIME[0.00047517s]

SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297746' WHERE `error_id` = '3283']
SQL RUNTIME[0.00176597s]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemNumUsers.0';]
SQL RUNTIME[0.00028801s]

SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297746' WHERE `error_id` = '3283']
SQL RUNTIME[0.00140500s]
SNMP STATUS[FALSE]
  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped.

 o Module time          0.0986s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-graphs.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-graphs.rrd N:0.0986]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.97]
RRD_STATUS[TRUE]



including: includes/polling/oids.inc.php
#####  Module Start: oids  #####


SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '169']
SQL RUNTIME[0.00037289s]
 o Module time          0.0014s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-oids.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-oids.rrd N:0.0014]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.98]
RRD_STATUS[TRUE]



including: includes/polling/probes.inc.php
#####  Module Start: probes  #####


SQL[SELECT * FROM `probes` WHERE `device_id` = '169']
SQL RUNTIME[0.00027800s]
 o Module time          0.0012s
RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-probes.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-probes.rrd N:0.0012]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.98]
RRD_STATUS[TRUE]


#####  172.21.99.138 [169] completed poller modules at 2023-02-13 15:15:46  #####

 o Graphs [checked]     availability, ping_snmp, uptime, temperature, voltage, capacity, runtime, frequency, load, ipsystemstats_ipv4, 
                        ipsystemstats_ipv4_frag,ipsystemstats_ipv6, ipsystemstats_ipv6_frag, bits, poller_perf, pollersnmp_count, 
                        pollersnmp_times,pollersnmp_errors_count, pollersnmp_errors_times, pollerdb_count, pollerdb_times, 
                        pollermemory_perf
 o Poller time          2.987 seconds

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '169';]
SQL RUNTIME[0.00025511s]
RRD /opt/observium/rrd/172.21.99.138/perf-poller.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-poller.rrd N:2.987]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.98]
RRD_STATUS[TRUE]

Updating 172.21.99.138 - 

 > $update_array /opt/observium/includes/polling/functions.inc.php:439 
array(
  [uptime]                => int(5571)
  [last_polled]           => array(
                               [0] => string(5) "NOW()"
                             )
  [last_polled_timetaken] => double(2.987)
  [device_state]          => string(2356) "a:5:{s:15:"poller_mod_perf";a:23:{s:6:"system";d:0.1501;s:2:"os";d:0.1131;s:7:"sensors";d:0.3201;s:6:"status";d:0.0423;s:7:"counter";d:0.0014;s:10:"processors";d:0.0019;s:8:"mempools";d:0.0012;s:7:"storage";d:0.0021;s:7:"ucd-mib";d:0.1763;s:13:"ipSystemStats";d:1.0497;s:5:"ports";d:0.8569;s:15:"printersupplies";d:0.001;s:10:"ucd-diskio";d:0.0009;s:4:"ospf";d:0.0001;s:3:"sla";d:0.0013;s:14:"mac-accounting";d:0.0014;s:12:"loadbalancer";d:0.0004;s:15:"entity-physical";d:0.0002;s:12:"applications";d:0.0016;s:9:"fdb-table";d:0.0842;s:6:"graphs";d:0.0986;s:4:"oids";d:0.0014;s:6:"probes";d:0.0012;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.45494604110717773;s:13:"EtherLike-MIB";d:0.03960895538330078;s:12:"Q-BRIDGE-MIB";d:0.15981793403625488;s:6:"IP-MIB";d:0.16146302223205566;}s:14:"poller_history";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:"discovery_history";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:"discovery_mod_perf";a:18:{s:2:"os";d:0.1205;s:4:"mibs";d:0.2058;s:5:"ports";d:0.2178;s:4:"oids";d:0.0018;s:12:"ip-addresses";d:0.3596;s:10:"processors";d:0.0658;s:8:"mempools";d:0.1013;s:9:"inventory";d:0.2745;s:15:"printersupplies";d:0.0014;s:7:"sensors";d:3.1239;s:7:"storage";d:0.0741;s:10:"neighbours";d:0.1398;s:9:"arp-table";d:0.103;s:14:"mac-accounting";d:0.0004;s:3:"sla";d:0.0372;s:16:"virtual-machines";d:0.0008;s:10:"ucd-diskio";d:0.0469;s:6:"graphs";d:0.0006;}}"
)
 

SQL[UPDATE `devices` set `uptime` ='5571',`last_polled` =NOW(),`last_polled_timetaken` ='2.987',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";d:0.1501;s:2:\"os\";d:0.1131;s:7:\"sensors\";d:0.3201;s:6:\"status\";d:0.0423;s:7:\"counter\";d:0.0014;s:10:\"processors\";d:0.0019;s:8:\"mempools\";d:0.0012;s:7:\"storage\";d:0.0021;s:7:\"ucd-mib\";d:0.1763;s:13:\"ipSystemStats\";d:1.0497;s:5:\"ports\";d:0.8569;s:15:\"printersupplies\";d:0.001;s:10:\"ucd-diskio\";d:0.0009;s:4:\"ospf\";d:0.0001;s:3:\"sla\";d:0.0013;s:14:\"mac-accounting\";d:0.0014;s:12:\"loadbalancer\";d:0.0004;s:15:\"entity-physical\";d:0.0002;s:12:\"applications\";d:0.0016;s:9:\"fdb-table\";d:0.0842;s:6:\"graphs\";d:0.0986;s:4:\"oids\";d:0.0014;s:6:\"probes\";d:0.0012;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.45494604110717773;s:13:\"EtherLike-MIB\";d:0.03960895538330078;s:12:\"Q-BRIDGE-MIB\";d:0.15981793403625488;s:6:\"IP-MIB\";d:0.16146302223205566;}s:14:\"poller_history\";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:\"discovery_history\";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.1205;s:4:\"mibs\";d:0.2058;s:5:\"ports\";d:0.2178;s:4:\"oids\";d:0.0018;s:12:\"ip-addresses\";d:0.3596;s:10:\"processors\";d:0.0658;s:8:\"mempools\";d:0.1013;s:9:\"inventory\";d:0.2745;s:15:\"printersupplies\";d:0.0014;s:7:\"sensors\";d:3.1239;s:7:\"storage\";d:0.0741;s:10:\"neighbours\";d:0.1398;s:9:\"arp-table\";d:0.103;s:14:\"mac-accounting\";d:0.0004;s:3:\"sla\";d:0.0372;s:16:\"virtual-machines\";d:0.0008;s:10:\"ucd-diskio\";d:0.0469;s:6:\"graphs\";d:0.0006;}}' WHERE `device_id` = '169']
SQL RUNTIME[0.00228596s]
 o Updated Data         uptime, last_polled, last_polled_timetaken, device_state
Checking alert 5 associated by 

Testing: device_status equals 0
 (value: 1)
NOT TRUE
%G[OK]%N
RRD /opt/observium/rrd/172.21.99.138/alert-5-device-169.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-5-device-169.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.99]
RRD_STATUS[TRUE]


SQL[INSERT INTO `alert_table` (`alert_table_id`,`count`,`state`,`alert_status`,`last_message`,`last_changed`,`last_checked`,`last_ok`,`last_failed`,`last_alerted`) VALUES ('11460','0','{\"metrics\":{\"sensor_value\":23.3}}','1','Checks OK','1676285543','1676297743','1676297743',NULL,'0'),('11457','0','{\"metrics\":{\"ifInOctets_perc\":0.0,\"ifOutOctets_perc\":0.0}}','1','Checks OK','1676285546','1676297746','1676297746',NULL,'0'),('11458','0','{\"metrics\":{\"ifInOctets_perc\":0.0,\"ifOutOctets_perc\":0.0}}','1','Checks OK','1676285546','1676297746','1676297746',NULL,'0'),('11459','0','{\"metrics\":{\"device_status\":\"1\"}}','1','Checks OK','1676294716','1676297746','1676297746','1676294408','1676294408') ON DUPLICATE KEY UPDATE `alert_table_id`=VALUES(`alert_table_id`),`count`=VALUES(`count`),`state`=VALUES(`state`),`alert_status`=VALUES(`alert_status`),`last_message`=VALUES(`last_message`),`last_changed`=VALUES(`last_changed`),`last_checked`=VALUES(`last_checked`),`last_ok`=VALUES(`last_ok`),`last_failed`=VALUES(`last_failed`),`last_alerted`=VALUES(`last_alerted`)]
SQL RUNTIME[0.00172901s]


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '3571573' AND `process_name` = 'poller.php' AND `device_id` = '169' AND `poller_id` = '0']
SQL RUNTIME[0.00170803s]
poller.php: 172.21.99.138 - 1 devices polled in 3.289 secs
#####  Completed polling run at 2023-02-13 15:15:46  #####

RRD /opt/observium/rrd/172.21.99.138/perf-pollerdb.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollerdb.rrd N:1:0.00290108:16:0.0700941:1:0.00230098:11:0.01203727722168:7:0.00798917:18:0.021889925003052:44:0.21857619285583:99:0.33668684786804]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:2.99]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/172.21.99.138/perf-pollermemory.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermemory.rrd N:25165824:25165824]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:3.00]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/172.21.99.138/perf-pollersnmp.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollersnmp.rrd N:23:0.69500970840454:12:1.9593214988708:U:U:35:2.6543312072754]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:3.00]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/172.21.99.138/perf-pollersnmp_errors.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollersnmp_errors.rrd N:14:0.54766345024109:U:U:14:0.54766345024109]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.01 s:0.01 r:3.00]
RRD_STATUS[TRUE]

NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Polled       1
 o Poller Time          3.289 secs
 o Memory usage         24MB (peak: 24MB)
 o MySQL Usage          Insert[1/0.003s] Update[16/0.07s] Delete[1/0.002s] Cell[11/0.012s] Row[18/0.022s] Rows[44/0.219s] Col[7/0.008s] 
                        Connect[1/0.001s](0.337s 10.237%) 
 o RRDTool Usage        update[53/0.059s] (0.059s 1.802%)
 o SNMP Usage           snmpget[23/0.695s] errors[/0s] snmpwalk[12/1.959s] (2.654s 80.703%)