DEBUG! CMD[/usr/bin/svn info /opt/observium]  CMD EXITCODE[0] CMD RUNTIME[0.0152s] CMD EXITDELAY[10ms] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: https://svn.observium.org/svn/observium/branches/stable Relative URL: ^/observium/branches/stable Repository Root: https://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 12523 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 12520 Last Changed Date: 2023-02-08 20:28:14 +0100 (Wed, 08 Feb 2023) ] DEFINITIONS loaded by: 0.15519 ms DEFINITIONS in memory: 15.5MB SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00040698s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00014114s]  SQL[SET SESSION `sql_mode` = 'NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00012803s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00014901s]  SQL[SELECT * FROM `config`] SQL RUNTIME[0.00025105s]  CMD[/bin/hostname -f]  CMD EXITCODE[0] CMD RUNTIME[0.0025s] STDOUT[ vm-observium ] SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)] SQL RUNTIME[0.00029111s]  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 23.2.12520 https://www.observium.org   CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.0196s] STDOUT[ Linux|5.15.0-58-generic|amd64|Ubuntu|20.04|vmware| ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0034s] STDOUT[ Python 3.8.10 ] SQL[SELECT version();] SQL RUNTIME[0.00021100s]  CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0036s] STDOUT[ NET-SNMP version: 5.8 ] CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0094s] STDOUT[ RRDtool 1.7.2 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0025s] CMD EXITDELAY[10ms] STDOUT[ /usr/bin/fping: Version 4.2 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0467s] STDOUT[ Apache/2.4.41 ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00036597s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00020909s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00018311s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00013208s]  SQL[SHOW VARIABLES LIKE 'log_bin'] SQL RUNTIME[0.17079616s]  SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00198984s]  ##### Software versions #####   o OS  Linux 5.15.0-58-generic [amd64] (Ubuntu 20.04)  o Apache  2.4.41  o PHP  7.4.3-4ubuntu2.17 (OPcache: DISABLED)  o Python  3.8.10  o MySQL  8.0.32-0ubuntu0.20.04.2 (extension: mysqli 7.4.3-4ubuntu2.17)  o SNMP  NET-SNMP 5.8  o RRDtool  1.7.2  o Fping  4.2 (IPv4 and IPv6) ##### Memory Limit #####   o PHP  Unlimited ##### DB info #####   o DB schema  478  o MySQL binlog  ON  o MySQL mode  NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MySQL  utf8mb3 ##### Timezones info #####   o Date  Monday, 13-Feb-23 15:15:43 CET  o PHP  +01:00  o MySQL  +01:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1676297743' AND `maint_end` > '1676297743'] SQL RUNTIME[0.00034118s] ##### Starting polling run at 2023-02-13 15:15:43 #####   SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `device_id` = '169' AND `poller_id` = '0' ORDER BY `device_id` ASC] SQL RUNTIME[0.00027394s]  SQL[SELECT * FROM `devices` WHERE `device_id` = '169'] SQL RUNTIME[0.00033808s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169'] SQL RUNTIME[0.00032997s]    /opt/observium/includes/polling/functions.inc.php:119  array( [device_id] => string(3) "169" [poller_id] => string(1) "0" [hostname] => string(13) "172.21.99.138" [sysName] => string(3) "nmc" [label] => null [ip] => string(13) "172.21.99.138" [snmp_community] => string(7) "private" [snmp_authlevel] => null [snmp_authname] => null [snmp_authpass] => null [snmp_authalgo] => null [snmp_cryptopass] => null [snmp_cryptoalgo] => null [snmp_context] => null [snmpable] => null [snmp_version] => string(2) "v1" [snmp_port] => string(3) "161" [snmp_timeout] => null [snmp_retries] => null [snmp_maxrep] => null [ssh_port] => string(2) "22" [agent_version] => null [snmp_transport] => string(3) "udp" [bgpLocalAs] => null [snmpEngineID] => string(0) "" [sysObjectID] => string(21) ".1.3.6.1.4.1.935.10.1" [sysDescr] => string(31) "Network Management Card for UPS" [sysContact] => string(24) "Technical Support Center" [version] => string(40) "SRV TK UPS: 05649-0599 Firmware: 3.1.0.0" [hardware] => string(8) "LINE-INT" [vendor] => string(11) "PowerWalker" [features] => null [location] => string(6) "SRV TK" [os] => string(8) "eppc-ups" [status] => string(1) "1" [status_type] => string(2) "ok" [ignore] => string(1) "0" [ignore_until] => null [asset_tag] => null [disabled] => string(1) "0" [uptime] => string(4) "5369" [last_rebooted] => string(10) "1676292173" [force_discovery] => string(1) "0" [last_polled] => string(19) "2023-02-13 15:12:25" [last_discovered] => string(19) "2023-02-13 15:10:16" [last_alerter] => string(19) "2023-02-13 15:12:12" [last_polled_timetaken] => string(4) "4.09" [last_discovered_timetaken] => string(4) "4.91" [purpose] => null [type] => string(5) "power" [serial] => null [icon] => null [device_state] => string(2333) "a:5:{s:15:"poller_mod_perf";a:23:{s:6:"system";d:0.1671;s:2:"os";d:0.1264;s:7:"sensors";d:0.354;s:6:"status";d:0.0536;s:7:"counter";d:0.0013;s:10:"processors";d:0.0021;s:8:"mempools";d:0.0012;s:7:"storage";d:0.0021;s:7:"ucd-mib";d:0.1503;s:13:"ipSystemStats";d:1.1039;s:5:"ports";d:1.8708;s:15:"printersupplies";d:0.0012;s:10:"ucd-diskio";d:0.0009;s:4:"ospf";d:0.0001;s:3:"sla";d:0.0014;s:14:"mac-accounting";d:0.0014;s:12:"loadbalancer";d:0.0003;s:15:"entity-physical";d:0.0002;s:12:"applications";d:0.0017;s:9:"fdb-table";d:0.0863;s:6:"graphs";d:0.0736;s:4:"oids";d:0.0012;s:6:"probes";d:0.0011;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.4544258117675781;s:13:"EtherLike-MIB";d:0.034970998764038086;s:12:"Q-BRIDGE-MIB";d:1.1510851383209229;s:6:"IP-MIB";d:0.1913011074066162;}s:14:"poller_history";a:42:{i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:"discovery_history";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:"discovery_mod_perf";a:18:{s:2:"os";d:0.1205;s:4:"mibs";d:0.2058;s:5:"ports";d:0.2178;s:4:"oids";d:0.0018;s:12:"ip-addresses";d:0.3596;s:10:"processors";d:0.0658;s:8:"mempools";d:0.1013;s:9:"inventory";d:0.2745;s:15:"printersupplies";d:0.0014;s:7:"sensors";d:3.1239;s:7:"storage";d:0.0741;s:10:"neighbours";d:0.1398;s:9:"arp-table";d:0.103;s:14:"mac-accounting";d:0.0004;s:3:"sla";d:0.0372;s:16:"virtual-machines";d:0.0008;s:10:"ucd-diskio";d:0.0469;s:6:"graphs";d:0.0006;}}" [distro] => null [distro_ver] => null [kernel] => null [arch] => null )   /opt/observium/includes/polling/functions.inc.php:120  array( [override_type] => string(5) "power" [ping_skip] => string(1) "1" )   /opt/observium/includes/polling/functions.inc.php:121  bool(false) SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '169' AND `poller_id` = '0'] SQL RUNTIME[0.00028181s]  SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('3571573','poller.php','3402670','0','php ./poller.php -d -h 169','1676297743','169')] SQL RUNTIME[0.00209093s]  SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00030780s] Cached 5 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '169'] SQL RUNTIME[0.00029302s] ##### 172.21.99.138 [169] #####   o OS  eppc-ups  o OS Group  ups  o Last poll duration  4.09 seconds  o Last Polled  2023-02-13 15:12:25  o SNMP Version  v1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.0283s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.935.10.1 .1.3.6.1.2.1.1.3.0 = 0:1:32:51.89 ] SNMP STATUS[TRUE]  o Device status  Device is reachable by SNMP (28.32ms) RRD /opt/observium/rrd/172.21.99.138/status.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/status.rrd N:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.03] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/172.21.99.138/ping_snmp.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/ping_snmp.rrd N:28.32] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.03] RRD_STATUS[TRUE]   SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169'] SQL RUNTIME[0.00047898s] Module [unix-agent] excluded in process [poller]. Module [wmi] excluded in process [poller]. Module [ipmi] excluded in process [poller]. Module [netstats] disabled by os definition in process [poller]. Module [bgp-peers] disabled by os definition in process [poller]. Module [junose-atm-vp] excluded in process [poller]. Module [wifi] disabled for device type 'power'. in process [poller]. Module [p2p-radios] disabled by os definition in process [poller]. Module [cisco-ipsec-flow-monitor] excluded in process [poller]. Module [cisco-remote-access-monitor] excluded in process [poller]. Module [cisco-cef] excluded in process [poller]. Module [lsp] disabled globally by config in process [poller]. Module [pseudowires] disabled by os definition in process [poller]. Module [arista-software-ip-forwarding] excluded in process [poller]. Module [cipsec-tunnels] excluded in process [poller]. Module [cisco-cbqos] excluded in process [poller]. Module [cisco-eigrp] excluded in process [poller]. Module [aruba-controller] excluded in process [poller]. Module [cisco-vpdn] excluded in process [poller]. Module [packages] disabled globally by config in process [poller].  o Modules Excluded  unix-agent, wmi, ipmi, junose-atm-vp, cisco-ipsec-flow-monitor, cisco-remote-access-monitor, cisco-cef, arista-software-ip-forwarding,cipsec-tunnels, cisco-cbqos, cisco-eigrp, aruba-controller, cisco-vpdn  o Modules Disabled  netstats, bgp-peers, wifi, p2p-radios, lsp, pseudowires, packages  o Modules Enabled  system, os, sensors, status, counter, processors, mempools, storage, ucd-mib, ipSystemStats, ports, printersupplies, ucd-diskio,ospf, sla, mac-accounting, loadbalancer, entity-physical, applications, fdb-table, graphs, oids, processes, probes including: includes/polling/system.inc.php ##### Module Start: system #####  JSON DECODE[Not string passed] JSON RAW[  > $str /opt/observium/includes/common.inc.php:5437  null ] JSON DECODE[Not string passed] JSON RAW[   /opt/observium/includes/common.inc.php:5437  null ] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00027204s]  o SNMPv2-MIB   CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0]  CMD EXITCODE[0] CMD RUNTIME[0.0353s] STDOUT[ sysUpTime.0 = 0:1:32:51.93 sysLocation.0 = "53 52 56 20 54 4B " sysContact.0 = "54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 43 65 6E 74 65 72 " sysName.0 = "4E 4D 43 " ] SNMP Hex string converted.. HEX: 53 52 56 20 54 4B STRING: SRV TK SNMP Hex string converted.. HEX: 54 65 63 68 6E 69 63 61 6C 20 53 75 70 70 6F 72 74 20 43 65 6E 74 65 72 STRING: Technical Support Center SNMP Hex string converted.. HEX: 4E 4D 43 STRING: NMC SNMP STATUS[TRUE] Timeticks converted 0:1:32:51.93 -> 5571 CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0235s] STDOUT[ "4E 65 74 77 6F 72 6B 20 4D 61 6E 61 67 65 6D 65 6E 74 20 43 61 72 64 20 66 6F 72 20 55 50 53 " ] SNMP Hex string converted.. HEX: 4E 65 74 77 6F 72 6B 20 4D 61 6E 61 67 65 6D 65 6E 74 20 43 61 72 64 20 66 6F 72 20 55 50 53 STRING: Network Management Card for UPS SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0239s] STDOUT[ .1.3.6.1.4.1.935.10.1 ] SNMP STATUS[TRUE]  Using SNMP Agent sysUpTime (5571 sec. => 1h 32m 51s) RRD /opt/observium/rrd/172.21.99.138/uptime.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/uptime.rrd N:5571] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.13] RRD_STATUS[TRUE]   o Uptime  1h 32m 51s  o Last reboot  2023-02-13 13:42:53   /opt/observium/includes/polling/system.inc.php:218  array( [use] => string(9) "sysUpTime" [sysUpTime] => int(5571) [uptime] => int(5571) [formatted] => string(10) "1h 32m 51s" [message] => string(26) "Using SNMP Agent sysUpTime" [previous] => string(4) "5369" [diff] => int(-202) [last_rebooted] => string(10) "1676292173" [rebooted] => int(0) ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3]  CMD EXITCODE[2] CMD RUNTIME[0.0428s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: .1.3.6.1.4.1.2021.10.1.5.1 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: .1.3.6.1.4.1.2021.10.1.5.2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: .1.3.6.1.4.1.2021.10.1.5.3 ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';] SQL RUNTIME[0.00033402s]  SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297743' WHERE `error_id` = '3275'] SQL RUNTIME[0.00191307s] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';] SQL RUNTIME[0.00031900s]  SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297743' WHERE `error_id` = '3275'] SQL RUNTIME[0.00137401s] SNMP STATUS[FALSE]  o sysObjectID  .1.3.6.1.4.1.935.10.1  o snmpEngineID    o sysDescr  Network Management Card for UPS  o sysName  NMC  o Location  SRV TK SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '169'] SQL RUNTIME[0.00023413s]  o Module time  0.1501s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-system.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-system.rrd N:0.1501] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.19] RRD_STATUS[TRUE]   including: includes/polling/os.inc.php ##### Module Start: os #####   CMD[/usr/bin/snmpget -v1 -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEIndentityUPSSerialNumber.0]  CMD EXITCODE[0] CMD RUNTIME[0.0259s] STDOUT[ "" ] SNMP STATUS[FALSE] SNMP ERROR[#1 - Empty response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1' AND `snmp_cmd` = 'snmpget' AND `mib` = 'EPPC-MIB' AND `oid` = 'upsEIndentityUPSSerialNumber.0';] SQL RUNTIME[0.00045395s]  SQL[UPDATE `snmp_errors` set `error_count` ='43',`updated` ='1676297743',`snmp_options` ='-OQUvx --hexOutputLength=0' WHERE `error_id` = '3276'] SQL RUNTIME[0.00179482s]  o OS Poller  OS CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputVA.0 upsEIdentityModel.0]  CMD EXITCODE[0] CMD RUNTIME[0.0303s] STDOUT[ upsESystemConfigOutputVA.0 = -1 upsEIdentityModel.0 = LINE-INT ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEIdentityDescription.0 upsEIdentityUPSFirmwareVerison.0 upsEIdentityAgentSoftwareVerison.0]  CMD EXITCODE[0] CMD RUNTIME[0.0446s] STDOUT[ upsEIdentityDescription.0 = SRV TK upsEIdentityUPSFirmwareVerison.0 = 05649-0599 upsEIdentityAgentSoftwareVerison.0 = 3.1.0.0 ] SNMP STATUS[TRUE]  o Type  Power  o Vendor  PowerWalker  o Hardware  LINE-INT  o Version  SRV TK UPS: 05649-0599 Firmware: 3.1.0.0  o Features    o Serial    o Asset    o Module time  0.1131s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-os.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-os.rrd N:0.1131] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.30] RRD_STATUS[TRUE]   including: includes/polling/sensors.inc.php ##### Module Start: sensors #####   SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '169' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','power','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','attenuation','snr','dust','concentration','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','distance','illuminance','wavelength','gauge')] SQL RUNTIME[0.00096512s]  SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '169' AND `entity_type` = 'sensor'] SQL RUNTIME[0.00035214s]  SQL[SELECT DISTINCT `sensor_oid` FROM `sensors` WHERE `device_id` = '169' AND `sensor_deleted` = '0' AND `poller_type` = 'snmp'] SQL RUNTIME[0.00037789s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.2.0 .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1 .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1 .1.3.6.1.4.1.935.10.1.1.2.18.1.2. .1.3.6.1.4.1.935.10.1.1.2.18.1.3. .1.3.6.1.4.1.935.10.1.1.2.18.1.7. .1.3.6.1.4.1.935.10.1.1.3.2.0 .1.3.6.1.4.1.935.10.1.1.3.3.0 .1.3.6.1.4.1.935.10.1.1.3.4.0 .1.3.6.1.4.1.935.10.1.1.3.5.0]  CMD EXITCODE[1] CMD RUNTIME[0.0155s] STDOUT[ ] STDERR[ .1.3.6.1.4.1.935.10.1.1.2.18.1.2.: Unknown Object Identifier () .1.3.6.1.4.1.935.10.1.1.2.18.1.3.: Unknown Object Identifier () .1.3.6.1.4.1.935.10.1.1.2.18.1.7.: Unknown Object Identifier () ] SNMP ERROR[#996 - MIB or oid not found] SNMP ERROR[#996 - MIB or oid not found] SNMP STATUS[FALSE]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00090599s] Checking (snmp) temperature System   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2449" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.4.1.935.10.1.1.2.2.0" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(21) "upsESystemTemperature" [sensor_index] => string(1) "0" [sensor_type] => string(30) "EPPC-MIB-upsESystemTemperature" [sensor_descr] => string(6) "System" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(2) "90" [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "22.9000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297541" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.2.0]  CMD EXITCODE[0] CMD RUNTIME[0.0234s] STDOUT[ 233 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(233) ) RRD /opt/observium/rrd/172.21.99.138/sensor-temperature-EPPC-MIB-upsESystemTemperature-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-temperature-EPPC-MIB-upsESystemTemperature-0.rrd N:23.3] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.36] RRD_STATUS[TRUE]  Checking alert 6 associated by Testing: sensor_value > 75 (value: 23.3) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/172.21.99.138/alert-6-sensor-2449.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-6-sensor-2449.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.36] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00094414s] Checking (snmp) voltage Input   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2454" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) ".1.3.6.1.4.1.935.10.1.1.2.16.1.3.1" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(22) "upsESystemInputVoltage" [sensor_index] => string(1) "1" [sensor_type] => string(31) "EPPC-MIB-upsESystemInputVoltage" [sensor_descr] => string(5) "Input" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(7) "266.685" [sensor_limit_warn] => null [sensor_limit_low] => string(7) "197.115" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(20) "233.8000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297541" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1]  CMD EXITCODE[0] CMD RUNTIME[0.0237s] STDOUT[ 2328 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(2328) ) RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemInputVoltage-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemInputVoltage-1.rrd N:232.8] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.39] RRD_STATUS[TRUE]  Checking (snmp) voltage Output   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2456" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.3." [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(23) "upsESystemOutputVoltage" [sensor_index] => string(1) "1" [sensor_type] => string(32) "EPPC-MIB-upsESystemOutputVoltage" [sensor_descr] => string(6) "Output" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(5) "264.5" [sensor_limit_warn] => string(3) "253" [sensor_limit_low] => string(5) "195.5" [sensor_limit_low_warn] => string(3) "207" [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1676297541" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.3.]  CMD EXITCODE[1] CMD RUNTIME[0.0168s] STDOUT[ ] STDERR[ .1.3.6.1.4.1.935.10.1.1.2.18.1.3.: Unknown Object Identifier () ] SNMP STATUS[FALSE] SNMP ERROR[#996 - MIB or oid not found]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => string(0) "" ) RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemOutputVoltage-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsESystemOutputVoltage-1.rrd N:] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.41] RRD_STATUS[TRUE]  Checking (snmp) voltage Battery   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2450" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.4.1.935.10.1.1.3.5.0" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(26) "upsEPositiveBatteryVoltage" [sensor_index] => string(1) "0" [sensor_type] => string(35) "EPPC-MIB-upsEPositiveBatteryVoltage" [sensor_descr] => string(7) "Battery" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(5) "93.61" [sensor_limit_warn] => null [sensor_limit_low] => string(5) "69.19" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "81.4000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297541" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.5.0]  CMD EXITCODE[0] CMD RUNTIME[0.0239s] STDOUT[ 814 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(814) ) RRD /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsEPositiveBatteryVoltage-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-voltage-EPPC-MIB-upsEPositiveBatteryVoltage-0.rrd N:81.4] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.00 s:0.00 r:0.44] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00070119s] Checking (snmp) capacity Battery Charge Remaining   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2451" [sensor_deleted] => string(1) "0" [sensor_class] => string(8) "capacity" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.4.1.935.10.1.1.3.4.0" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(35) "upsEBatteryEstimatedChargeRemaining" [sensor_index] => string(1) "0" [sensor_type] => string(44) "EPPC-MIB-upsEBatteryEstimatedChargeRemaining" [sensor_descr] => string(24) "Battery Charge Remaining" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => string(2) "10" [sensor_limit_low_warn] => string(2) "20" [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(20) "100.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297541" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.4.0]  CMD EXITCODE[0] CMD RUNTIME[0.0249s] STDOUT[ 100 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(100) ) RRD /opt/observium/rrd/172.21.99.138/sensor-capacity-EPPC-MIB-upsEBatteryEstimatedChargeRemaining-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-capacity-EPPC-MIB-upsEBatteryEstimatedChargeRemaining-0.rrd N:100] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.47] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00064898s] Checking (snmp) runtime Battery Runtime   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2453" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "runtime" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.4.1.935.10.1.1.3.2.0" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(20) "upsESecondsOnBattery" [sensor_index] => string(1) "0" [sensor_type] => string(29) "EPPC-MIB-upsESecondsOnBattery" [sensor_descr] => string(15) "Battery Runtime" [sensor_unit] => null [sensor_multiplier] => string(9) "0.0166667" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297542" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.2.0]  CMD EXITCODE[0] CMD RUNTIME[0.0238s] STDOUT[ 0 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(0) ) RRD /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsESecondsOnBattery-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsESecondsOnBattery-0.rrd N:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.50] RRD_STATUS[TRUE]  Checking (snmp) runtime Battery Runtime Remaining   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2452" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "runtime" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.4.1.935.10.1.1.3.3.0" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(36) "upsEBatteryEstimatedMinutesRemaining" [sensor_index] => string(1) "0" [sensor_type] => string(45) "EPPC-MIB-upsEBatteryEstimatedMinutesRemaining" [sensor_descr] => string(25) "Battery Runtime Remaining" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => string(1) "5" [sensor_limit_low_warn] => string(2) "20" [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(20) "294.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297542" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.3.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.0242s] STDOUT[ 292 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(292) ) RRD /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsEBatteryEstimatedMinutesRemaining-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-runtime-EPPC-MIB-upsEBatteryEstimatedMinutesRemaining-0.rrd N:292] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.53] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00077891s] Checking (snmp) frequency Input   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2455" [sensor_deleted] => string(1) "0" [sensor_class] => string(9) "frequency" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) ".1.3.6.1.4.1.935.10.1.1.2.16.1.2.1" [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(24) "upsESystemInputFrequency" [sensor_index] => string(1) "1" [sensor_type] => string(33) "EPPC-MIB-upsESystemInputFrequency" [sensor_descr] => string(5) "Input" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(6) "-0.095" [sensor_limit_warn] => null [sensor_limit_low] => string(6) "-0.105" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "-0.1000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1676297542" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1]  CMD EXITCODE[0] CMD RUNTIME[0.0239s] STDOUT[ -1 ] SNMP STATUS[TRUE]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => int(-1) ) RRD /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemInputFrequency-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemInputFrequency-1.rrd N:-0.1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.55] RRD_STATUS[TRUE]  Checking (snmp) frequency Output   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2457" [sensor_deleted] => string(1) "0" [sensor_class] => string(9) "frequency" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.2." [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(25) "upsESystemOutputFrequency" [sensor_index] => string(1) "1" [sensor_type] => string(34) "EPPC-MIB-upsESystemOutputFrequency" [sensor_descr] => string(6) "Output" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(4) "52.5" [sensor_limit_warn] => string(4) "51.5" [sensor_limit_low] => string(4) "47.5" [sensor_limit_low_warn] => string(4) "48.5" [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1676297542" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.2.]  CMD EXITCODE[1] CMD RUNTIME[0.0204s] STDOUT[ ] STDERR[ .1.3.6.1.4.1.935.10.1.1.2.18.1.2.: Unknown Object Identifier () ] SNMP STATUS[FALSE] SNMP ERROR[#996 - MIB or oid not found]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => string(0) "" ) RRD /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemOutputFrequency-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-frequency-EPPC-MIB-upsESystemOutputFrequency-1.rrd N:] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.58] RRD_STATUS[TRUE]   SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00113392s] Checking (snmp) load Output   /opt/observium/includes/entities/sensor.inc.php:781  array( [sensor_id] => string(4) "2458" [sensor_deleted] => string(1) "0" [sensor_class] => string(4) "load" [device_id] => string(3) "169" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) ".1.3.6.1.4.1.935.10.1.1.2.18.1.7." [sensor_mib] => string(8) "EPPC-MIB" [sensor_object] => string(20) "upsESystemOutputLoad" [sensor_index] => string(1) "1" [sensor_type] => string(29) "EPPC-MIB-upsESystemOutputLoad" [sensor_descr] => string(6) "Output" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(2) "90" [sensor_limit_warn] => string(2) "75" [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1676297542" [sensor_last_change] => string(10) "1676285543" ) CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.18.1.7.]  CMD EXITCODE[1] CMD RUNTIME[0.017s] STDOUT[ ] STDERR[ .1.3.6.1.4.1.935.10.1.1.2.18.1.7.: Unknown Object Identifier () ] SNMP STATUS[FALSE] SNMP ERROR[#996 - MIB or oid not found]    /opt/observium/includes/entities/sensor.inc.php:856  array( [sensor_value] => string(0) "" ) RRD /opt/observium/rrd/172.21.99.138/sensor-load-EPPC-MIB-upsESystemOutputLoad-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/sensor-load-EPPC-MIB-upsESystemOutputLoad-1.rrd N:] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.60] RRD_STATUS[TRUE]  MultiUpdate sensors DB. SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`) VALUES ('2449','23.3','ok','','1676285543','1676297743'),('2454','232.8','ok','','1676285543','1676297744'),('2456','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744'),('2450','81.4','ok','','1676285543','1676297744'),('2451','100','ok','','1676285543','1676297744'),('2453','0','ok','','1676285543','1676297744'),('2452','292','ok','','1676285543','1676297744'),('2455','-0.1','ok','','1676285543','1676297744'),('2457','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744'),('2458','','alert','Sensor critical thresholds exceeded.','1676285543','1676297744') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)] SQL RUNTIME[0.00289488s] +---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+ | Descr | Class | Type | Origin | Value | Event | Last Changed | +---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+ | System | temperature | EPPC-MIB-upsESystemTemperature | snmp | 23.3°C | ok | 2023-02-13 11:52:23 | | Input | voltage | EPPC-MIB-upsESystemInputVoltage | snmp | 232.8V | ok | 2023-02-13 11:52:23 | | Output | voltage | EPPC-MIB-upsESystemOutputVoltage | snmp | V | alert | 2023-02-13 11:52:23 | | Battery | voltage | EPPC-MIB-upsEPositiveBatteryVoltage | snmp | 81.4V | ok | 2023-02-13 11:52:23 | | Battery Charge Remaining | capacity | EPPC-MIB-upsEBatteryEstimatedChargeRemaining | snmp | 100% | ok | 2023-02-13 11:52:23 | | Battery Runtime | runtime | EPPC-MIB-upsESecondsOnBattery | snmp | 0min | ok | 2023-02-13 11:52:23 | | Battery Runtime Remaining | runtime | EPPC-MIB-upsEBatteryEstimatedMinutesRemaining | snmp | 292min | ok | 2023-02-13 11:52:23 | | Input | frequency | EPPC-MIB-upsESystemInputFrequency | snmp | -0.1Hz | ok | 2023-02-13 11:52:23 | | Output | frequency | EPPC-MIB-upsESystemOutputFrequency | snmp | Hz | alert | 2023-02-13 11:52:23 | | Output | load | EPPC-MIB-upsESystemOutputLoad | snmp | % | alert | 2023-02-13 11:52:23 | +---------------------------+-------------+-----------------------------------------------+--------+------------+-------+---------------------+  o Module time  0.3201s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-sensors.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-sensors.rrd N:0.3201] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.63] RRD_STATUS[TRUE]   including: includes/polling/status.inc.php ##### Module Start: status #####   SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0';] SQL RUNTIME[0.00053811s]  o Status Count  2 SQL[SELECT DISTINCT `status_oid` FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0' AND `poller_type` = 'snmp'] SQL RUNTIME[0.00034213s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.4.1.935.10.1.1.2.1.0 .1.3.6.1.4.1.935.10.1.1.3.1.0]  CMD EXITCODE[0] CMD RUNTIME[0.0274s] STDOUT[ .1.3.6.1.4.1.935.10.1.1.2.1.0 = 4 .1.3.6.1.4.1.935.10.1.1.3.1.0 = 2 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_deleted` = '0' ORDER BY `status_oid`] SQL RUNTIME[0.00068188s] Checking (snmp) System Status value taken from oid_cache RRD /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsESystemStatus-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsESystemStatus-0.rrd N:4] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.66] RRD_STATUS[TRUE]  Checking (snmp) Battery Status value taken from oid_cache RRD /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsEBatteryStatus-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/status-EPPC-MIB-upsEBatteryStatus-0.rrd N:2] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.66] RRD_STATUS[TRUE]  MultiUpdate status DB. SQL[INSERT INTO `status` (`status_id`,`status_value`,`status_name`,`status_event`,`status_last_change`,`status_polled`) VALUES ('820','4','line','ok','1676285543','1676297744'),('821','2','batteryNormal','ok','1676285543','1676297744') ON DUPLICATE KEY UPDATE `status_id`=VALUES(`status_id`),`status_value`=VALUES(`status_value`),`status_name`=VALUES(`status_name`),`status_event`=VALUES(`status_event`),`status_last_change`=VALUES(`status_last_change`),`status_polled`=VALUES(`status_polled`)] SQL RUNTIME[0.00205898s] +----------------+-------------------+-------+--------+---------------+--------+---------------------+ | Descr | Type | Index | Origin | Value | Status | Last Changed | +----------------+-------------------+-------+--------+---------------+--------+---------------------+ | System Status | upsESystemStatus | 0 | snmp | line | ok | 2023-02-13 11:52:23 | | Battery Status | upsEBatteryStatus | 0 | snmp | batteryNormal | ok | 2023-02-13 11:52:23 | +----------------+-------------------+-------+--------+---------------+--------+---------------------+  o Module time  0.0423s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-status.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-status.rrd N:0.0423] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.67] RRD_STATUS[TRUE]   including: includes/polling/counter.inc.php ##### Module Start: counter #####   SQL[SELECT EXISTS (SELECT 1 FROM `counters` WHERE `device_id` = '169' AND `counter_deleted` = '0')] SQL RUNTIME[0.00035501s]  o Module time  0.0014s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-counter.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-counter.rrd N:0.0014] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.67] RRD_STATUS[TRUE]   including: includes/polling/processors.inc.php ##### Module Start: processors #####   SQL[SELECT `processor_oid` FROM `processors` WHERE `device_id` = '169' AND `processor_oid` REGEXP '^\\.?[0-9]+(\\.[0-9]+)+$' AND `processor_type` != 'wmi'] SQL RUNTIME[0.00025296s]  SQL[SELECT * FROM `processors` WHERE `device_id` = '169'] SQL RUNTIME[0.00027204s]  o Module time  0.0019s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-processors.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-processors.rrd N:0.0019] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]   including: includes/polling/mempools.inc.php ##### Module Start: mempools #####   SQL[SELECT * FROM `mempools` WHERE `device_id` = '169'] SQL RUNTIME[0.00024605s]  o Module time  0.0012s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-mempools.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-mempools.rrd N:0.0012] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]   including: includes/polling/storage.inc.php ##### Module Start: storage #####   SQL[SELECT `storage_mib`, `storage_object`, `storage_hc`, GROUP_CONCAT(`storage_index` SEPARATOR ',') AS `indexes` FROM `storage` WHERE `device_id` = '169' GROUP BY `storage_mib`, `storage_object`, `storage_hc`] SQL RUNTIME[0.00034308s]  SQL[SELECT * FROM `storage` WHERE `device_id` = '169'] SQL RUNTIME[0.00025201s]  o Module time  0.0021s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-storage.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-storage.rrd N:0.0021] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.68] RRD_STATUS[TRUE]   including: includes/polling/ucd-mib.inc.php ##### Module Start: ucd-mib #####   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' systemStats]  CMD EXITCODE[0] CMD RUNTIME[0.0397s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0]  CMD EXITCODE[2] CMD RUNTIME[0.1244s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalFree.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memShared.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memBuffer.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memCached.0 ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = 'memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0';] SQL RUNTIME[0.00043797s]  SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297744' WHERE `error_id` = '3281'] SQL RUNTIME[0.00238490s] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = 'memTotalSwap.0 memAvailSwap.0 memTotalReal.0 memAvailReal.0 memTotalFree.0 memShared.0 memBuffer.0 memCached.0';] SQL RUNTIME[0.00031996s]  SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297744' WHERE `error_id` = '3281'] SQL RUNTIME[0.00150013s] SNMP STATUS[FALSE]  o Module time  0.1763s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-mib.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-mib.rrd N:0.1763] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:0.86] RRD_STATUS[TRUE]   including: includes/polling/ipSystemStats.inc.php ##### Module Start: ipSystemStats #####   o Collecting  ipSystemStats CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipSystemStats]  CMD EXITCODE[0] CMD RUNTIME[1.044s] STDOUT[ ipSystemStatsInReceives.ipv4 = 0 ipSystemStatsInReceives.ipv6 = 123 ipSystemStatsHCInReceives.ipv4 = 0 ipSystemStatsHCInReceives.ipv6 = 123 ipSystemStatsInOctets.ipv4 = 7446625 ipSystemStatsInOctets.ipv6 = 0 ipSystemStatsHCInOctets.ipv4 = 7446811 ipSystemStatsHCInOctets.ipv6 = 0 ipSystemStatsInHdrErrors.ipv4 = 0 ipSystemStatsInHdrErrors.ipv6 = 0 ipSystemStatsInNoRoutes.ipv4 = 0 ipSystemStatsInNoRoutes.ipv6 = 0 ipSystemStatsInAddrErrors.ipv4 = 0 ipSystemStatsInAddrErrors.ipv6 = 0 ipSystemStatsInUnknownProtos.ipv4 = 187 ipSystemStatsInUnknownProtos.ipv6 = 0 ipSystemStatsInTruncatedPkts.ipv4 = 0 ipSystemStatsInTruncatedPkts.ipv6 = 0 ipSystemStatsInForwDatagrams.ipv4 = 0 ipSystemStatsInForwDatagrams.ipv6 = 0 ipSystemStatsHCInForwDatagrams.ipv4 = 0 ipSystemStatsHCInForwDatagrams.ipv6 = 0 ipSystemStatsReasmReqds.ipv4 = 0 ipSystemStatsReasmReqds.ipv6 = 0 ipSystemStatsReasmOKs.ipv4 = 0 ipSystemStatsReasmOKs.ipv6 = 0 ipSystemStatsReasmFails.ipv4 = 0 ipSystemStatsReasmFails.ipv6 = 0 ipSystemStatsInDiscards.ipv4 = 0 ipSystemStatsInDiscards.ipv6 = 5 ipSystemStatsInDelivers.ipv4 = 0 ipSystemStatsInDelivers.ipv6 = 12 ipSystemStatsHCInDelivers.ipv4 = 0 ipSystemStatsHCInDelivers.ipv6 = 0 ipSystemStatsOutRequests.ipv4 = 0 ipSystemStatsOutRequests.ipv6 = 0 ipSystemStatsHCOutRequests.ipv4 = 0 ipSystemStatsHCOutRequests.ipv6 = 0 ipSystemStatsOutNoRoutes.ipv4 = 0 ipSystemStatsOutNoRoutes.ipv6 = 0 ipSystemStatsOutForwDatagrams.ipv4 = 0 ipSystemStatsOutForwDatagrams.ipv6 = 0 ipSystemStatsHCOutForwDatagrams.ipv4 = 0 ipSystemStatsHCOutForwDatagrams.ipv6 = 0 ipSystemStatsOutDiscards.ipv4 = 0 ipSystemStatsOutDiscards.ipv6 = 0 ipSystemStatsOutFragReqds.ipv4 = 0 ipSystemStatsOutFragReqds.ipv6 = 0 ipSystemStatsOutFragOKs.ipv4 = 0 ipSystemStatsOutFragOKs.ipv6 = 0 ipSystemStatsOutFragFails.ipv4 = 3869252 ipSystemStatsOutFragFails.ipv6 = 0 ipSystemStatsOutFragCreates.ipv4 = 3869434 ipSystemStatsOutFragCreates.ipv6 = 0 ipSystemStatsOutTransmits.ipv4 = 551 ipSystemStatsOutTransmits.ipv6 = 0 ipSystemStatsHCOutTransmits.ipv4 = 551 ipSystemStatsHCOutTransmits.ipv6 = 0 ipSystemStatsOutOctets.ipv4 = 0 ipSystemStatsOutOctets.ipv6 = 0 ipSystemStatsHCOutOctets.ipv4 = 0 ipSystemStatsHCOutOctets.ipv6 = 0 ipSystemStatsInMcastPkts.ipv4 = 2 ipSystemStatsInMcastPkts.ipv6 = 7 ipSystemStatsHCInMcastPkts.ipv4 = 2 ipSystemStatsHCInMcastPkts.ipv6 = 7 ipSystemStatsInMcastOctets.ipv4 = 0 ipSystemStatsInMcastOctets.ipv6 = 0 ipSystemStatsHCInMcastOctets.ipv4 = 0 ipSystemStatsHCInMcastOctets.ipv6 = 0 ipSystemStatsOutMcastPkts.ipv4 = 24531 ipSystemStatsOutMcastPkts.ipv6 = 0 ipSystemStatsHCOutMcastPkts.ipv4 = 24531 ipSystemStatsHCOutMcastPkts.ipv6 = 0 ipSystemStatsOutMcastOctets.ipv4 = 7 ipSystemStatsOutMcastOctets.ipv6 = 0 ipSystemStatsHCOutMcastOctets.ipv4 = 7 ipSystemStatsHCOutMcastOctets.ipv6 = 0 ipSystemStatsInBcastPkts.ipv4 = 0:0:00:00.00 ipSystemStatsInBcastPkts.ipv6 = 0:0:00:00.00 ipSystemStatsHCInBcastPkts.ipv4 = 0 ipSystemStatsHCInBcastPkts.ipv6 = 0 ] SNMP STATUS[TRUE]  o Address Families   ipv4RRD /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv4.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv4.rrd N:0:0:0:187:0:0:0:0:0:0:0:0:0:3869252:3869434:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:1.91] RRD_STATUS[TRUE]   ipv6RRD /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv6.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/ipSystemStats-ipv6.rrd N:123:0:0:0:0:0:0:0:5:0:0:0:0:0:0:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:1.91] RRD_STATUS[TRUE]    o Graphs  ipsystemstats_ipv4 ipsystemstats_ipv4_frag ipsystemstats_ipv6 ipsystemstats_ipv6_frag  o Module time  1.0497s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ipSystemStats.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ipSystemStats.rrd N:1.0497] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:1.91] RRD_STATUS[TRUE]   including: includes/polling/ports.inc.php ##### Module Start: ports #####   SQL[SELECT * FROM `ports` WHERE `device_id` = '169'] SQL RUNTIME[0.00066209s]  SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '169' AND `entity_type` = 'port'] SQL RUNTIME[0.00033617s] Module [ports_etherlike] disabled globally by config in process [poller]. Module [ports_junoseatmvp] excluded for device os in process [poller]. Module [ports_fdbcount] disabled globally by config in process [poller]. Module [ports_separate_walk] disabled globally by config in process [poller].  o Caching Oids  Used full table ifEntry/ifXEntry snmpwalk. ifEntry Added Oid END 'ifOutQLen' for snmpwalk 'ifEntry'. CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -CE 'ifOutQLen' -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifEntry]  CMD EXITCODE[0] CMD RUNTIME[0.4176s] STDOUT[ ifIndex.1 = 1 ifIndex.2 = 2 ifDescr.1 = lo ifDescr.2 = eth0 ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifMtu.1 = 1500 ifMtu.2 = 1500 ifSpeed.1 = 0 ifSpeed.2 = 10000000 ifPhysAddress.1 = ifPhysAddress.2 = 0:20:85:e5:a6:86 ifAdminStatus.1 = up ifAdminStatus.2 = up ifOperStatus.1 = up ifOperStatus.2 = up ifLastChange.1 = 0:0:00:00.00 ifLastChange.2 = 0:0:00:08.67 ifInOctets.1 = 1656158 ifInOctets.2 = 5799751 ifInUcastPkts.1 = 7111 ifInUcastPkts.2 = 12011 ifInNUcastPkts.1 = 0 ifInNUcastPkts.2 = 25083 ifInDiscards.1 = 0 ifInDiscards.2 = 0 ifInErrors.1 = 0 ifInErrors.2 = 0 ifInUnknownProtos.1 = 0 ifInUnknownProtos.2 = 187 ifOutOctets.1 = 1656158 ifOutOctets.2 = 2218856 ifOutUcastPkts.1 = 7111 ifOutUcastPkts.2 = 11325 ifOutNUcastPkts.1 = 0 ifOutNUcastPkts.2 = 9 ifOutDiscards.1 = 0 ifOutDiscards.2 = 0 ifOutErrors.1 = 0 ifOutErrors.2 = 0 ] SNMP STATUS[TRUE] ifXEntry Added Oid END 'ifCounterDiscontinuityTime' for snmpwalk 'ifXEntry'. CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -CE 'ifCounterDiscontinuityTime' -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifXEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0332s] STDOUT[ ] SNMP STATUS[TRUE]   o ADSL-LINE-MIB   SQL[SELECT EXISTS (SELECT 1 FROM `ports` WHERE `device_id` = '169' AND `ifType` IN ('adsl', 'vdsl', 'vdsl2'))] SQL RUNTIME[0.00064397s]   o EtherLike-MIB  dot3StatsDuplexStatus CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EtherLike-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot3StatsDuplexStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0371s] STDOUT[ ] SNMP STATUS[TRUE]   o Q-BRIDGE-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1dBasePortIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0373s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qPvid]  CMD EXITCODE[0] CMD RUNTIME[0.066s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qVlanStaticUntaggedPorts]  CMD EXITCODE[0] CMD RUNTIME[0.0503s] STDOUT[ ] SNMP STATUS[TRUE] dot1qVlanStaticUntaggedPorts print_cli_table() argument should be an array. Please report this error to developers. [[IP-MIB]] o IP-MIB  IP-MIB ipIfStats CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsX -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipIfStatsHCInOctets]  CMD EXITCODE[0] CMD RUNTIME[0.0719s] STDOUT[ ipIfStatsHCInOctets[ipv4][1] = 1656158 ipIfStatsHCInOctets[ipv4][2] = 5802923 ipIfStatsHCInOctets[ipv6][1] = 0 ipIfStatsHCInOctets[ipv6][2] = 0 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsX -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipIfStatsHCOutOctets]  CMD EXITCODE[0] CMD RUNTIME[0.0847s] STDOUT[ ipIfStatsHCOutOctets[ipv4][1] = 0 ipIfStatsHCOutOctets[ipv4][2] = 0 ipIfStatsHCOutOctets[ipv6][1] = 0 ipIfStatsHCOutOctets[ipv6][2] = 0 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7725'] SQL RUNTIME[0.00044107s]  SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '169'] SQL RUNTIME[0.00033021s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725'] SQL RUNTIME[0.00030494s]  SQL[SELECT * FROM `devices` WHERE `device_id` = '169'] SQL RUNTIME[0.00035214s]  SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169'] SQL RUNTIME[0.00031996s] RRD /opt/observium/rrd/172.21.99.138/port-1-ipv6-octets.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/port-1-ipv6-octets.rrd N:0:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.74] RRD_STATUS[TRUE]   SQL[SELECT EXISTS (SELECT 1 FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725' AND `attrib_type` = 'ipv6-octets')] SQL RUNTIME[0.00032401s]  SQL[UPDATE `entity_attribs` set `attrib_value` ='1' WHERE `entity_type` = 'port' AND `entity_id` = '7725' AND `attrib_type` = 'ipv6-octets'] SQL RUNTIME[0.00028610s] Timeticks converted 0:0:00:00.00 -> 0 IFLASTCHANGE = 1676297744s - 5571s + 0s BC SUB: 1656158 - 1656158 = 0 ifInOctets (0 B) 0 Bps 203 secs BC SUB: 1656158 - 1656158 = 0 ifOutOctets (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifInErrors (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifOutErrors (0 B) 0 Bps 203 secs BC SUB: 7111 - 7111 = 0 ifInUcastPkts (0 B) 0 Bps 203 secs BC SUB: 7111 - 7111 = 0 ifOutUcastPkts (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifInNUcastPkts (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifOutNUcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifInBroadcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifOutBroadcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifInMulticastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifOutMulticastPkts (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifInDiscards (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifOutDiscards (0 B) 0 Bps 203 secs RRD /opt/observium/rrd/172.21.99.138/port-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/port-1.rrd N:1656158:1656158:0:0:7111:7111:0:0:0:0:0:U:U:U:U] RRD RUNTIME[0.0013s] RRD STDOUT[OK u:0.01 s:0.01 r:2.75] RRD_STATUS[TRUE]  Checking alert 3 associated by Testing: ifInOctets_perc > 80 (value: 0) NOT TRUE %G[OK]%N Testing: ifOutOctets_perc > 80 (value: 0) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/172.21.99.138/alert-3-port-7725.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-3-port-7725.rrd N:1:1] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:2.75] RRD_STATUS[TRUE]   SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7726'] SQL RUNTIME[0.00035787s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726'] SQL RUNTIME[0.00055504s] RRD /opt/observium/rrd/172.21.99.138/port-2-ipv6-octets.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/port-2-ipv6-octets.rrd N:0:0] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:2.75] RRD_STATUS[TRUE]   SQL[SELECT EXISTS (SELECT 1 FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726' AND `attrib_type` = 'ipv6-octets')] SQL RUNTIME[0.00030708s]  SQL[UPDATE `entity_attribs` set `attrib_value` ='1' WHERE `entity_type` = 'port' AND `entity_id` = '7726' AND `attrib_type` = 'ipv6-octets'] SQL RUNTIME[0.00027919s] Timeticks converted 0:0:00:08.67 -> 8 IFLASTCHANGE = 1676297744s - 5571s + 8s BC SUB: 5799751 - 5615350 = 184401 ifInOctets (184401 B) 908.37931034483 Bps 203 secs BC SUB: 2218856 - 2157316 = 61540 ifOutOctets (61540 B) 303.15270935961 Bps 203 secs BC SUB: 0 - 0 = 0 ifInErrors (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifOutErrors (0 B) 0 Bps 203 secs BC SUB: 12011 - 11685 = 326 ifInUcastPkts (326 B) 1.6059113300493 Bps 203 secs BC SUB: 11325 - 11005 = 320 ifOutUcastPkts (320 B) 1.576354679803 Bps 203 secs BC SUB: 25083 - 24176 = 907 ifInNUcastPkts (907 B) 4.4679802955665 Bps 203 secs BC SUB: 9 - 9 = 0 ifOutNUcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifInBroadcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifOutBroadcastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifInMulticastPkts (0 B) 0 Bps 203 secs BC SUB: - 0 = 0 ifOutMulticastPkts (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifInDiscards (0 B) 0 Bps 203 secs BC SUB: 0 - 0 = 0 ifOutDiscards (0 B) 0 Bps 203 secs RRD /opt/observium/rrd/172.21.99.138/port-2.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/port-2.rrd N:5799751:2218856:0:0:12011:11325:25083:9:0:0:187:U:U:U:U] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:2.76] RRD_STATUS[TRUE]  Checking alert 3 associated by Testing: ifInOctets_perc > 80 (value: 0) NOT TRUE %G[OK]%N Testing: ifOutOctets_perc > 80 (value: 0) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/172.21.99.138/alert-3-port-7726.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-3-port-7726.rrd N:1:1] RRD RUNTIME[0.0012s] RRD STDOUT[OK u:0.01 s:0.01 r:2.76] RRD_STATUS[TRUE]  MultiUpdate ports states DB. SQL[INSERT INTO `ports` (`port_id`,`ifIndex`,`device_id`,`poll_time`,`poll_period`,`ifInOctets`,`ifInOctets_rate`,`ifOutOctets`,`ifOutOctets_rate`,`ifInErrors`,`ifInErrors_rate`,`ifInErrors_delta`,`ifOutErrors`,`ifOutErrors_rate`,`ifOutErrors_delta`,`ifInUcastPkts`,`ifInUcastPkts_rate`,`ifOutUcastPkts`,`ifOutUcastPkts_rate`,`ifInNUcastPkts`,`ifInNUcastPkts_rate`,`ifOutNUcastPkts`,`ifOutNUcastPkts_rate`,`ifInBroadcastPkts`,`ifInBroadcastPkts_rate`,`ifOutBroadcastPkts`,`ifOutBroadcastPkts_rate`,`ifInMulticastPkts`,`ifInMulticastPkts_rate`,`ifOutMulticastPkts`,`ifOutMulticastPkts_rate`,`ifInDiscards`,`ifInDiscards_rate`,`ifOutDiscards`,`ifOutDiscards_rate`,`ifInOctets_perc`,`ifOutOctets_perc`,`ifOctets_rate`,`ifUcastPkts_rate`,`ifErrors_rate`,`ifDiscards_rate`) VALUES ('7725','1','169','1676297746','203','1656158','0','1656158','0','0','0','0','0','0','0','7111','0','7111','0','0','0','0','0','','0','','0','','0','','0','0','0','0','0','0','0','0','0','0','0'),('7726','2','169','1676297746','203','5799751','908.37931034483','2218856','303.15270935961','0','0','0','0','0','0','12011','1.6059113300493','11325','1.576354679803','25083','4.4679802955665','9','0','','0','','0','','0','','0','0','0','0','0','0','0','1211.5320197044','3.1822660098522','0','0') ON DUPLICATE KEY UPDATE `port_id`=VALUES(`port_id`),`ifIndex`=VALUES(`ifIndex`),`device_id`=VALUES(`device_id`),`poll_time`=VALUES(`poll_time`),`poll_period`=VALUES(`poll_period`),`ifInOctets`=VALUES(`ifInOctets`),`ifInOctets_rate`=VALUES(`ifInOctets_rate`),`ifOutOctets`=VALUES(`ifOutOctets`),`ifOutOctets_rate`=VALUES(`ifOutOctets_rate`),`ifInErrors`=VALUES(`ifInErrors`),`ifInErrors_rate`=VALUES(`ifInErrors_rate`),`ifInErrors_delta`=VALUES(`ifInErrors_delta`),`ifOutErrors`=VALUES(`ifOutErrors`),`ifOutErrors_rate`=VALUES(`ifOutErrors_rate`),`ifOutErrors_delta`=VALUES(`ifOutErrors_delta`),`ifInUcastPkts`=VALUES(`ifInUcastPkts`),`ifInUcastPkts_rate`=VALUES(`ifInUcastPkts_rate`),`ifOutUcastPkts`=VALUES(`ifOutUcastPkts`),`ifOutUcastPkts_rate`=VALUES(`ifOutUcastPkts_rate`),`ifInNUcastPkts`=VALUES(`ifInNUcastPkts`),`ifInNUcastPkts_rate`=VALUES(`ifInNUcastPkts_rate`),`ifOutNUcastPkts`=VALUES(`ifOutNUcastPkts`),`ifOutNUcastPkts_rate`=VALUES(`ifOutNUcastPkts_rate`),`ifInBroadcastPkts`=VALUES(`ifInBroadcastPkts`),`ifInBroadcastPkts_rate`=VALUES(`ifInBroadcastPkts_rate`),`ifOutBroadcastPkts`=VALUES(`ifOutBroadcastPkts`),`ifOutBroadcastPkts_rate`=VALUES(`ifOutBroadcastPkts_rate`),`ifInMulticastPkts`=VALUES(`ifInMulticastPkts`),`ifInMulticastPkts_rate`=VALUES(`ifInMulticastPkts_rate`),`ifOutMulticastPkts`=VALUES(`ifOutMulticastPkts`),`ifOutMulticastPkts_rate`=VALUES(`ifOutMulticastPkts_rate`),`ifInDiscards`=VALUES(`ifInDiscards`),`ifInDiscards_rate`=VALUES(`ifInDiscards_rate`),`ifOutDiscards`=VALUES(`ifOutDiscards`),`ifOutDiscards_rate`=VALUES(`ifOutDiscards_rate`),`ifInOctets_perc`=VALUES(`ifInOctets_perc`),`ifOutOctets_perc`=VALUES(`ifOutOctets_perc`),`ifOctets_rate`=VALUES(`ifOctets_rate`),`ifUcastPkts_rate`=VALUES(`ifUcastPkts_rate`),`ifErrors_rate`=VALUES(`ifErrors_rate`),`ifDiscards_rate`=VALUES(`ifDiscards_rate`)] SQL RUNTIME[0.00250697s] +---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+ | ifIndex | Label | Type | Speed | BPS In | BPS Out | Data In | Data Out | PPS In | PPS Out | HC | +---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+ | 1 | lo | Loopback | 0bps | 0bps | 0bps | 0B | 0B | 0 | 0 | N | | 2 | eth0 | Ethernet | 10Mbps | 7.27kbps | 2.43kbps | 180kB | 60.1kB | 1.61 | 1.58 | N | +---------+-------+----------+--------+----------+----------+---------+----------+--------+---------+----+  o Module time  0.8569s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ports.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ports.rrd N:0.8569] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.77] RRD_STATUS[TRUE]   including: includes/polling/printersupplies.inc.php ##### Module Start: printersupplies #####   SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '169'] SQL RUNTIME[0.00026798s]  o Module time  0.0010s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-printersupplies.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-printersupplies.rrd N:0.001] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.77] RRD_STATUS[TRUE]   including: includes/polling/ucd-diskio.inc.php ##### Module Start: ucd-diskio #####   SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '169'] SQL RUNTIME[0.00024009s]  o Module time  0.0009s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-diskio.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ucd-diskio.rrd N:0.0009] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.77] RRD_STATUS[TRUE]   including: includes/polling/ospf.inc.php ##### Module Start: ospf #####   o Module time  0.0001s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-ospf.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-ospf.rrd N:0.0001] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.78] RRD_STATUS[TRUE]   including: includes/polling/sla.inc.php ##### Module Start: sla #####   SQL[SELECT * FROM `slas` WHERE `device_id` = '169' AND `deleted` = 0;] SQL RUNTIME[0.00028610s]  o MIBs    o Module time  0.0013s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-sla.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-sla.rrd N:0.0013] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.78] RRD_STATUS[TRUE]   including: includes/polling/mac-accounting.inc.php ##### Module Start: mac-accounting #####   o MIBs   SQL[SELECT * FROM `mac_accounting` WHERE `device_id` = '169'] SQL RUNTIME[0.00032496s]   o Module time  0.0014s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-mac-accounting.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-mac-accounting.rrd N:0.0014] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.78] RRD_STATUS[TRUE]   including: includes/polling/loadbalancer.inc.php ##### Module Start: loadbalancer #####   o Module time  0.0004s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-loadbalancer.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-loadbalancer.rrd N:0.0004] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.78] RRD_STATUS[TRUE]   including: includes/polling/entity-physical.inc.php ##### Module Start: entity-physical #####   o Module time  0.0002s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-entity-physical.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-entity-physical.rrd N:0.0002] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.78] RRD_STATUS[TRUE]   including: includes/polling/applications.inc.php ##### Module Start: applications #####   SQL[SELECT * FROM `applications` WHERE `device_id` = '169'] SQL RUNTIME[0.00024796s]  SQL[SELECT * FROM `applications` WHERE `device_id` = '169' AND `app_lastpolled` < '1675692946'] SQL RUNTIME[0.00023079s]  o Module time  0.0016s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-applications.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-applications.rrd N:0.0016] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.79] RRD_STATUS[TRUE]   including: includes/polling/fdb-table.inc.php ##### Module Start: fdb-table #####   SQL[SELECT `ifIndex`,`port_id`,`ifDescr`,`port_label_short` FROM `ports` WHERE `device_id` = '169'] SQL RUNTIME[0.00027704s]  SQL[SELECT * FROM `vlans_fdb` WHERE `device_id` = '169'] SQL RUNTIME[0.00024796s]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1qTpFdbEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0439s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dot1dBasePortIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0338s] STDOUT[ ] SNMP STATUS[TRUE] Module [ports_fdbcount] disabled globally by config in process [poller].  o Module time  0.0842s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-fdb-table.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-fdb-table.rrd N:0.0842] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.87] RRD_STATUS[TRUE]   including: includes/polling/graphs.inc.php ##### Module Start: graphs #####   o HOST-RESOURCES-MIB    o HOST-RESOURCES-MIB  hrSystemProcesses SQL[SELECT `object` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'oid' AND `disabled` = '1' AND `mib` = 'HOST-RESOURCES-MIB'] SQL RUNTIME[0.00037885s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrSystemProcesses.0]  CMD EXITCODE[2] CMD RUNTIME[0.0254s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: hrSystemProcesses.0 ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemProcesses.0';] SQL RUNTIME[0.00046301s]  SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297746' WHERE `error_id` = '3282'] SQL RUNTIME[0.02854204s] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemProcesses.0';] SQL RUNTIME[0.00039005s]  SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297746' WHERE `error_id` = '3282'] SQL RUNTIME[0.00169086s] SNMP STATUS[FALSE]  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped. hrSystemNumUsers CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrSystemNumUsers.0]  CMD EXITCODE[2] CMD RUNTIME[0.0256s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: hrSystemNumUsers.0 ] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemNumUsers.0';] SQL RUNTIME[0.00047517s]  SQL[UPDATE `snmp_errors` set `error_count` ='85',`updated` ='1676297746' WHERE `error_id` = '3283'] SQL RUNTIME[0.00176597s] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '169' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemNumUsers.0';] SQL RUNTIME[0.00028801s]  SQL[UPDATE `snmp_errors` set `error_count` ='86',`updated` ='1676297746' WHERE `error_id` = '3283'] SQL RUNTIME[0.00140500s] SNMP STATUS[FALSE]  WARNING, latest snmp walk/get return not good exitstatus for 'HOST-RESOURCES-MIB', RRD update skipped.  o Module time  0.0986s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-graphs.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-graphs.rrd N:0.0986] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.97] RRD_STATUS[TRUE]   including: includes/polling/oids.inc.php ##### Module Start: oids #####   SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '169'] SQL RUNTIME[0.00037289s]  o Module time  0.0014s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-oids.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-oids.rrd N:0.0014] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.98] RRD_STATUS[TRUE]   including: includes/polling/probes.inc.php ##### Module Start: probes #####   SQL[SELECT * FROM `probes` WHERE `device_id` = '169'] SQL RUNTIME[0.00027800s]  o Module time  0.0012s RRD /opt/observium/rrd/172.21.99.138/perf-pollermodule-probes.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermodule-probes.rrd N:0.0012] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.98] RRD_STATUS[TRUE]   ##### 172.21.99.138 [169] completed poller modules at 2023-02-13 15:15:46 #####   o Graphs [checked]  availability, ping_snmp, uptime, temperature, voltage, capacity, runtime, frequency, load, ipsystemstats_ipv4, ipsystemstats_ipv4_frag,ipsystemstats_ipv6, ipsystemstats_ipv6_frag, bits, poller_perf, pollersnmp_count, pollersnmp_times,pollersnmp_errors_count, pollersnmp_errors_times, pollerdb_count, pollerdb_times, pollermemory_perf  o Poller time  2.987 seconds SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '169';] SQL RUNTIME[0.00025511s] RRD /opt/observium/rrd/172.21.99.138/perf-poller.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-poller.rrd N:2.987] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.98] RRD_STATUS[TRUE]  Updating 172.21.99.138 -  > $update_array /opt/observium/includes/polling/functions.inc.php:439  array( [uptime] => int(5571) [last_polled] => array( [0] => string(5) "NOW()" ) [last_polled_timetaken] => double(2.987) [device_state] => string(2356) "a:5:{s:15:"poller_mod_perf";a:23:{s:6:"system";d:0.1501;s:2:"os";d:0.1131;s:7:"sensors";d:0.3201;s:6:"status";d:0.0423;s:7:"counter";d:0.0014;s:10:"processors";d:0.0019;s:8:"mempools";d:0.0012;s:7:"storage";d:0.0021;s:7:"ucd-mib";d:0.1763;s:13:"ipSystemStats";d:1.0497;s:5:"ports";d:0.8569;s:15:"printersupplies";d:0.001;s:10:"ucd-diskio";d:0.0009;s:4:"ospf";d:0.0001;s:3:"sla";d:0.0013;s:14:"mac-accounting";d:0.0014;s:12:"loadbalancer";d:0.0004;s:15:"entity-physical";d:0.0002;s:12:"applications";d:0.0016;s:9:"fdb-table";d:0.0842;s:6:"graphs";d:0.0986;s:4:"oids";d:0.0014;s:6:"probes";d:0.0012;}s:17:"poller_ports_perf";a:4:{s:6:"IF-MIB";d:0.45494604110717773;s:13:"EtherLike-MIB";d:0.03960895538330078;s:12:"Q-BRIDGE-MIB";d:0.15981793403625488;s:6:"IP-MIB";d:0.16146302223205566;}s:14:"poller_history";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:"discovery_history";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:"discovery_mod_perf";a:18:{s:2:"os";d:0.1205;s:4:"mibs";d:0.2058;s:5:"ports";d:0.2178;s:4:"oids";d:0.0018;s:12:"ip-addresses";d:0.3596;s:10:"processors";d:0.0658;s:8:"mempools";d:0.1013;s:9:"inventory";d:0.2745;s:15:"printersupplies";d:0.0014;s:7:"sensors";d:3.1239;s:7:"storage";d:0.0741;s:10:"neighbours";d:0.1398;s:9:"arp-table";d:0.103;s:14:"mac-accounting";d:0.0004;s:3:"sla";d:0.0372;s:16:"virtual-machines";d:0.0008;s:10:"ucd-diskio";d:0.0469;s:6:"graphs";d:0.0006;}}" ) SQL[UPDATE `devices` set `uptime` ='5571',`last_polled` =NOW(),`last_polled_timetaken` ='2.987',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";d:0.1501;s:2:\"os\";d:0.1131;s:7:\"sensors\";d:0.3201;s:6:\"status\";d:0.0423;s:7:\"counter\";d:0.0014;s:10:\"processors\";d:0.0019;s:8:\"mempools\";d:0.0012;s:7:\"storage\";d:0.0021;s:7:\"ucd-mib\";d:0.1763;s:13:\"ipSystemStats\";d:1.0497;s:5:\"ports\";d:0.8569;s:15:\"printersupplies\";d:0.001;s:10:\"ucd-diskio\";d:0.0009;s:4:\"ospf\";d:0.0001;s:3:\"sla\";d:0.0013;s:14:\"mac-accounting\";d:0.0014;s:12:\"loadbalancer\";d:0.0004;s:15:\"entity-physical\";d:0.0002;s:12:\"applications\";d:0.0016;s:9:\"fdb-table\";d:0.0842;s:6:\"graphs\";d:0.0986;s:4:\"oids\";d:0.0014;s:6:\"probes\";d:0.0012;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.45494604110717773;s:13:\"EtherLike-MIB\";d:0.03960895538330078;s:12:\"Q-BRIDGE-MIB\";d:0.15981793403625488;s:6:\"IP-MIB\";d:0.16146302223205566;}s:14:\"poller_history\";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:\"discovery_history\";a:4:{i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.1205;s:4:\"mibs\";d:0.2058;s:5:\"ports\";d:0.2178;s:4:\"oids\";d:0.0018;s:12:\"ip-addresses\";d:0.3596;s:10:\"processors\";d:0.0658;s:8:\"mempools\";d:0.1013;s:9:\"inventory\";d:0.2745;s:15:\"printersupplies\";d:0.0014;s:7:\"sensors\";d:3.1239;s:7:\"storage\";d:0.0741;s:10:\"neighbours\";d:0.1398;s:9:\"arp-table\";d:0.103;s:14:\"mac-accounting\";d:0.0004;s:3:\"sla\";d:0.0372;s:16:\"virtual-machines\";d:0.0008;s:10:\"ucd-diskio\";d:0.0469;s:6:\"graphs\";d:0.0006;}}' WHERE `device_id` = '169'] SQL RUNTIME[0.00228596s]  o Updated Data  uptime, last_polled, last_polled_timetaken, device_state Checking alert 5 associated by Testing: device_status equals 0 (value: 1) NOT TRUE %G[OK]%N RRD /opt/observium/rrd/172.21.99.138/alert-5-device-169.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/alert-5-device-169.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.99] RRD_STATUS[TRUE]   SQL[INSERT INTO `alert_table` (`alert_table_id`,`count`,`state`,`alert_status`,`last_message`,`last_changed`,`last_checked`,`last_ok`,`last_failed`,`last_alerted`) VALUES ('11460','0','{\"metrics\":{\"sensor_value\":23.3}}','1','Checks OK','1676285543','1676297743','1676297743',NULL,'0'),('11457','0','{\"metrics\":{\"ifInOctets_perc\":0.0,\"ifOutOctets_perc\":0.0}}','1','Checks OK','1676285546','1676297746','1676297746',NULL,'0'),('11458','0','{\"metrics\":{\"ifInOctets_perc\":0.0,\"ifOutOctets_perc\":0.0}}','1','Checks OK','1676285546','1676297746','1676297746',NULL,'0'),('11459','0','{\"metrics\":{\"device_status\":\"1\"}}','1','Checks OK','1676294716','1676297746','1676297746','1676294408','1676294408') ON DUPLICATE KEY UPDATE `alert_table_id`=VALUES(`alert_table_id`),`count`=VALUES(`count`),`state`=VALUES(`state`),`alert_status`=VALUES(`alert_status`),`last_message`=VALUES(`last_message`),`last_changed`=VALUES(`last_changed`),`last_checked`=VALUES(`last_checked`),`last_ok`=VALUES(`last_ok`),`last_failed`=VALUES(`last_failed`),`last_alerted`=VALUES(`last_alerted`)] SQL RUNTIME[0.00172901s]  SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '3571573' AND `process_name` = 'poller.php' AND `device_id` = '169' AND `poller_id` = '0'] SQL RUNTIME[0.00170803s] poller.php: 172.21.99.138 - 1 devices polled in 3.289 secs ##### Completed polling run at 2023-02-13 15:15:46 #####  RRD /opt/observium/rrd/172.21.99.138/perf-pollerdb.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollerdb.rrd N:1:0.00290108:16:0.0700941:1:0.00230098:11:0.01203727722168:7:0.00798917:18:0.021889925003052:44:0.21857619285583:99:0.33668684786804] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:2.99] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/172.21.99.138/perf-pollermemory.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollermemory.rrd N:25165824:25165824] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:3.00] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/172.21.99.138/perf-pollersnmp.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollersnmp.rrd N:23:0.69500970840454:12:1.9593214988708:U:U:35:2.6543312072754] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:3.00] RRD_STATUS[TRUE]  RRD /opt/observium/rrd/172.21.99.138/perf-pollersnmp_errors.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/172.21.99.138/perf-pollersnmp_errors.rrd N:14:0.54766345024109:U:U:14:0.54766345024109] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.01 s:0.01 r:3.00] RRD_STATUS[TRUE]  NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Polled  1  o Poller Time  3.289 secs  o Memory usage  24MB (peak: 24MB)  o MySQL Usage  Insert[1/0.003s] Update[16/0.07s] Delete[1/0.002s] Cell[11/0.012s] Row[18/0.022s] Rows[44/0.219s] Col[7/0.008s] Connect[1/0.001s](0.337s 10.237%)   o RRDTool Usage  update[53/0.059s] (0.059s 1.802%)  o SNMP Usage  snmpget[23/0.695s] errors[/0s] snmpwalk[12/1.959s] (2.654s 80.703%)