DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0155s]
CMD EXITDELAY[10ms]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: https://svn.observium.org/svn/observium/branches/stable
Relative URL: ^/observium/branches/stable
Repository Root: https://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 12523
Node Kind: directory
Schedule: normal
Last Changed Author: adama
Last Changed Rev: 12520
Last Changed Date: 2023-02-08 20:28:14 +0100 (Wed, 08 Feb 2023)

]
DEFINITIONS loaded by: 0.15485 ms

DEFINITIONS in memory: 15.4MB


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00025296s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00014210s]

SQL[SET SESSION `sql_mode` = 'NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00012183s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00013113s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00021005s]

CMD[/bin/hostname -f]

CMD EXITCODE[0]
CMD RUNTIME[0.003s]
STDOUT[
vm-observium
]

SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)]
SQL RUNTIME[0.00031710s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00022578s]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                          Observium Professional 23.2.12520
                                  https://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.022s]
STDOUT[
Linux|5.15.0-58-generic|amd64|Ubuntu|20.04|vmware|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0035s]
STDOUT[
Python 3.8.10
]

SQL[SELECT version();]
SQL RUNTIME[0.00023413s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0036s]
STDOUT[
NET-SNMP version: 5.8
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0099s]
CMD EXITDELAY[10ms]
STDOUT[
RRDtool 1.7.2  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0025s]
STDOUT[
/usr/bin/fping: Version 4.2
/usr/bin/fping: comments to david@schweikert.ch
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0444s]
STDOUT[
Apache/2.4.41
]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00023603s]

SQL[SHOW VARIABLES LIKE 'log_bin']
SQL RUNTIME[0.04011703s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00188708s]

#####  Software versions  #####

 o OS                   Linux 5.15.0-58-generic [amd64] (Ubuntu 20.04)
 o Apache               2.4.41
 o PHP                  7.4.3-4ubuntu2.17 (OPcache: DISABLED)
 o Python               3.8.10
 o MySQL                8.0.32-0ubuntu0.20.04.2 (extension: mysqli 7.4.3-4ubuntu2.17)
 o SNMP                 NET-SNMP 5.8
 o RRDtool              1.7.2
 o Fping                4.2 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  Unlimited

#####  DB info  #####

 o DB schema            478
 o MySQL binlog         ON
 o MySQL mode           NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8mb3

#####  Timezones info  #####

 o Date                 Monday, 13-Feb-23 15:16:13 CET
 o PHP                  +01:00
 o MySQL                +01:00


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00026679s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00017905s]
#####  Starting discovery run at 2023-02-13 15:16:13  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `device_id` = '169' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00035882s]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0574s]
STDOUT[
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.935.10.1
.1.3.6.1.2.1.1.3.0 = 0:1:33:21.44
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169']
SQL RUNTIME[0.00043488s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '169' AND `poller_id` = '0']
SQL RUNTIME[0.00027585s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('3572974','discovery.php','3402670','0','php ./discovery.php -d -h 169','1676297773','169')]
SQL RUNTIME[0.00173593s]
#####  172.21.99.138 [169]  #####

 o OS Type              eppc-ups
 o OS Group             ups
 o SNMP Version         v1
 o Last discovery       2023-02-13 15:10:16
 o Last duration        4.91 seconds

#####  Module Start: os  #####


CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0288s]
STDOUT[
Network Management Card for UPS
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0275s]
STDOUT[
.1.3.6.1.4.1.935.10.1
]
SNMP STATUS[TRUE]
+-------------+---------------------------------+
| OID         |                                 |
+-------------+---------------------------------+
| sysDescr    | Network Management Card for UPS |
| sysObjectID | .1.3.6.1.4.1.935.10.1           |
+-------------+---------------------------------+

 o Detect OS matched (eppc-ups: EPPC UPS): 
+-------------+-----------------------+-----------------------+
| OID         | Matched definition    |                       |
+-------------+-----------------------+-----------------------+
| sysObjectID | .1.3.6.1.4.1.935.10.1 | .1.3.6.1.4.1.935.10.1 |
+-------------+-----------------------+-----------------------+


 o Duration             0.0927s

#####  Module Start: mibs  #####


CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']

CMD EXITCODE[0]
CMD RUNTIME[0.0151s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2'

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.9.1.2]

CMD EXITCODE[0]
CMD RUNTIME[0.063s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1
.1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.10.3.1.1
.1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.6.3.11.3.1.1
.1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.6.3.15.2.1.1
.1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.6.3.16.2.1.1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysORDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.077s]
STDOUT[
sysORDescr.1 = The MIB Module from SNMPv2 entities
sysORDescr.2 = SNMP Management Architecture MIB
sysORDescr.3 = Message Processing and Dispatching MIB
sysORDescr.4 = USM User MIB
sysORDescr.5 = VACM MIB
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m OSPFV3-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ospfv3AdminStatus.0]

CMD EXITCODE[2]
CMD RUNTIME[0.0311s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: OSPFV3-MIB::ospfv3AdminStatus.0
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
Store in cache OID: OSPFV3-MIB::ospfv3AdminStatus.0
 o MIBs discovered      <empty>
SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00042295s]

+-----------------------+--------------------+---------+---------------------+
| Identity              | MIB                | Source  | Status              |
+-----------------------+--------------------+---------+---------------------+
| .1.3.6.1.6.3.1        | SNMPv2-MIB         | sysORID | MIB already defined |
| .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined |
| .1.3.6.1.6.3.11.3.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.15.2.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.16.2.1.1 | -                  | sysORID | Unknown Identity    |
+-----------------------+--------------------+---------+---------------------+


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00034595s]
JSON DECODE[Not string passed]
JSON RAW[


 > $str /opt/observium/includes/common.inc.php:5437 
null

]

SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00024915s]


  /opt/observium/includes/discovery/mibs.inc.php:313 
array(
  [0]  => string(8) "EPPC-MIB"
  [1]  => string(10) "SNMPv2-MIB"
  [2]  => string(18) "SNMP-FRAMEWORK-MIB"
  [3]  => string(6) "IF-MIB"
  [4]  => string(13) "ADSL-LINE-MIB"
  [5]  => string(13) "EtherLike-MIB"
  [6]  => string(10) "ENTITY-MIB"
  [7]  => string(17) "ENTITY-SENSOR-MIB"
  [8]  => string(12) "UCD-SNMP-MIB"
  [9]  => string(18) "HOST-RESOURCES-MIB"
  [10] => string(12) "Q-BRIDGE-MIB"
  [11] => string(6) "IP-MIB"
  [12] => string(8) "IPV6-MIB"
  [13] => string(8) "LLDP-MIB"
  [14] => string(13) "CISCO-CDP-MIB"
  [15] => string(15) "DISMAN-PING-MIB"
)

 o Duration             0.2047s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_vrf']
SQL RUNTIME[0.00025010s]
Module [vrf] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ports']
SQL RUNTIME[0.00024080s]
#####  Module Start: ports  #####

 o Caching OIDs         ifDescr 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.046s]
STDOUT[
ifDescr.1 = lo
ifDescr.2 = eth0
]
SNMP STATUS[TRUE]
ifAlias 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifAlias]

CMD EXITCODE[0]
CMD RUNTIME[0.0357s]
STDOUT[

]
SNMP STATUS[TRUE]
ifName 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifName]

CMD EXITCODE[0]
CMD RUNTIME[0.0333s]
STDOUT[

]
SNMP STATUS[TRUE]
ifType 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifType]

CMD EXITCODE[0]
CMD RUNTIME[0.0442s]
STDOUT[
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd
]
SNMP STATUS[TRUE]
ifOperStatus 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0636s]
STDOUT[
ifOperStatus.1 = up
ifOperStatus.2 = up
]
SNMP STATUS[TRUE]



  /opt/observium/includes/discovery/ports.inc.php:44 
array(
  [1] => array(
           [ifDescr]      => string(2) "lo"
           [ifType]       => string(16) "softwareLoopback"
           [ifOperStatus] => string(2) "up"
         )
  [2] => array(
           [ifDescr]      => string(4) "eth0"
           [ifType]       => string(14) "ethernetCsmacd"
           [ifOperStatus] => string(2) "up"
         )
)
 o Caching DB           
SQL[SELECT * FROM `ports` WHERE `device_id` = '169']
SQL RUNTIME[0.00065207s]
2 ports
 o Discovering ports    ..
+---------+---------+--------+---------+------------------+-------------+---------+
| ifIndex | ifDescr | ifName | ifAlias | ifType           | Oper Status | Ignored |
+---------+---------+--------+---------+------------------+-------------+---------+
| 1       | lo      |        | ...     | softwareLoopback | up          | no      |
| 2       | eth0    |        | ...     | ethernetCsmacd   | up          | no      |
+---------+---------+--------+---------+------------------+-------------+---------+


 o Duration             0.2379s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ports-stack']
SQL RUNTIME[0.00035286s]
Module [ports-stack] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_vlans']
SQL RUNTIME[0.00026798s]
Module [vlans] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_oids']
SQL RUNTIME[0.00029707s]
#####  Module Start: oids  #####


SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '169']
SQL RUNTIME[0.00032115s]

SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1']
SQL RUNTIME[0.00022507s]

 o Duration             0.0018s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ip-addresses']
SQL RUNTIME[0.00025201s]
#####  Module Start: ip-addresses  #####


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00024199s]
JSON DECODE[Not string passed]
JSON RAW[


  /opt/observium/includes/common.inc.php:5437 
null

]
 o IP-MIB               
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAdEntIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0486s]
STDOUT[
ipAdEntIfIndex.127.0.0.1 = 1
ipAdEntIfIndex.172.21.99.138 = 2
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAdEntNetMask]

CMD EXITCODE[0]
CMD RUNTIME[0.0489s]
STDOUT[
ipAdEntNetMask.127.0.0.1 = 255.255.255.255
ipAdEntNetMask.172.21.99.138 = 255.255.255.0
]
SNMP STATUS[TRUE]
Added 127.0.0.1
.Added 172.21.99.138
.
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0388s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressType]

CMD EXITCODE[0]
CMD RUNTIME[0.0508s]
STDOUT[
ipAddressType.ipv6.".".172.21.99.152 = "C8 1F 66 28 F1 DE "
ipAddressType.ipv6.".".172.21.99.254 = "00 50 56 B2 94 36 "
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressPrefix]

CMD EXITCODE[0]
CMD RUNTIME[0.0509s]
STDOUT[
ipAddressPrefix.ipv6.".".172.21.99.152 = 0:0:00:00.00
ipAddressPrefix.ipv6.".".172.21.99.254 = 0:0:00:00.00
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressOrigin]

CMD EXITCODE[0]
CMD RUNTIME[0.0547s]
STDOUT[
ipAddressOrigin.ipv6.".".172.21.99.152 = 3
ipAddressOrigin.ipv6.".".172.21.99.254 = 3
]
SNMP STATUS[TRUE]
Unknown IP index: ..172.21.99.152
Unknown IP index: ..172.21.99.254

 o IPV6-MIB             
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipv6AddrEntry]

CMD EXITCODE[0]
CMD RUNTIME[1.0363s]
STDOUT[

]
SNMP STATUS[TRUE]

 o LLDP-MIB             

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '169']
SQL RUNTIME[0.00040722s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '169' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00027800s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7725']
SQL RUNTIME[0.00033498s]

SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '169']
SQL RUNTIME[0.00036502s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725']
SQL RUNTIME[0.00041199s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '169']
SQL RUNTIME[0.00031400s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169']
SQL RUNTIME[0.00035000s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32']
SQL RUNTIME[0.00025511s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '169' AND `ifIndex` = '2' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00026011s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7726']
SQL RUNTIME[0.00031495s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726']
SQL RUNTIME[0.00027609s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.21.99.0/24']
SQL RUNTIME[0.00024295s]

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '169']
SQL RUNTIME[0.00031495s]

SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '169']
SQL RUNTIME[0.00028181s]
+---------+---------+-------------+------------------+----------------+----------+--------+
| ifIndex | ifDescr | IP: Version | Address          | Network        | Type     | Origin |
+---------+---------+-------------+------------------+----------------+----------+--------+
| 1       | lo      | IPv4        | 127.0.0.1/32     | 127.0.0.1/32   | loopback |        |
| 2       | eth0    | IPv4        | 172.21.99.138/24 | 172.21.99.0/24 | private  |        |
+---------+---------+-------------+------------------+----------------+----------+--------+


 o Changes              2 unchanged
 o Duration             1.3725s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_processors']
SQL RUNTIME[0.00027299s]
#####  Module Start: processors  #####

 o UCD-SNMP-MIB         
SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '169' AND `processor_type` != 'ucd-old')]
SQL RUNTIME[0.00029993s]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ssCpuIdle.0]

CMD EXITCODE[2]
CMD RUNTIME[0.024s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: UCD-SNMP-MIB::ssCpuIdle.0
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrProcessorLoad]

CMD EXITCODE[0]
CMD RUNTIME[0.0342s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `processors` WHERE `device_id` = '169']
SQL RUNTIME[0.00056911s]

 o Duration             0.0659s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_mempools']
SQL RUNTIME[0.00032997s]
#####  Module Start: mempools  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]

CMD EXITCODE[2]
CMD RUNTIME[0.0709s]
STDOUT[

]
STDERR[
Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memTotalReal.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memAvailReal.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memBuffer.0

Error in packet
Reason: (noSuchName) There is no such variable name in this MIB.
Failed object: memCached.0
]
SNMP ERROR[#1000 - Failed response]
SNMP ERROR[#1000 - Failed response]
SNMP STATUS[FALSE]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0395s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `mempools` WHERE `device_id` = '169']
SQL RUNTIME[0.00047493s]

 o Duration             0.1178s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_inventory']
SQL RUNTIME[0.00041318s]
#####  Module Start: inventory  #####

 o ENTITY-MIB           ENTITY-MIB 
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1281s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entAliasMappingIdentifier]

CMD EXITCODE[0]
CMD RUNTIME[0.0355s]
STDOUT[

]
SNMP STATUS[TRUE]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrDeviceEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0359s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrProcessorEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0361s]
STDOUT[

]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '169']
SQL RUNTIME[0.00043893s]


SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '169']
SQL RUNTIME[0.00028300s]

 o Duration             0.2484s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_printersupplies']
SQL RUNTIME[0.00031590s]
#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '169']
SQL RUNTIME[0.00025988s]


 o Duration             0.0022s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_sensors']
SQL RUNTIME[0.00028014s]
#####  Module Start: sensors  #####

 o EPPC-MIB             upsESystemTemperature [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.0358s]
STDOUT[
upsESystemTemperature.0 = 236
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemTemperature

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOverTemperatureSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.0351s]
STDOUT[
upsESystemConfigOverTemperatureSetPoint.0 = 900
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemConfigOverTemperatureSetPoint
Discover sensor: [class: temperature, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.2.0, index: 0, type: EPPC-MIB-upsESystemTemperature, descr: System, scale: 0.1, limits: (, , , 90), CURRENT: 23.6, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0')]
SQL RUNTIME[0.00060010s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0']
SQL RUNTIME[0.00037599s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2449' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027990s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2449' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023580s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-temperature-eppc-mib-upsESystemTemperature.rrd'
] upsEEnvironmentCurrentTemperature [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentCurrentTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.0374s]
STDOUT[
upsEEnvironmentCurrentTemperature.0 = -1
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentTemperature

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentTemperatureLowSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.0408s]
STDOUT[
upsEEnvironmentTemperatureLowSetPoint.0 = 150
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureLowSetPoint

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentTemperatureHighSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.0373s]
STDOUT[
upsEEnvironmentTemperatureHighSetPoint.0 = 500
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureHighSetPoint
Excluded by current value (-1) in invalid range [-1].
] upsEEnvironmentCurrentHumidity [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentCurrentHumidity]

CMD EXITCODE[0]
CMD RUNTIME[0.0395s]
STDOUT[
upsEEnvironmentCurrentHumidity.0 = -1
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentHumidity

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentHumidityLowSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.0387s]
STDOUT[
upsEEnvironmentHumidityLowSetPoint.0 = 50
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityLowSetPoint

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentHumidityHighSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.0382s]
STDOUT[
upsEEnvironmentHumidityHighSetPoint.0 = 90
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityHighSetPoint
Excluded by current value (-1) in invalid range [-1].
] upsEPositiveBatteryVoltage [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEPositiveBatteryVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.0535s]
STDOUT[
upsEPositiveBatteryVoltage.0 = 814
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEPositiveBatteryVoltage
Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.5.0, index: 0, type: EPPC-MIB-upsEPositiveBatteryVoltage, descr: Battery, scale: 0.1, limits: (, , , ), CURRENT: 81.4, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0')]
SQL RUNTIME[0.00042200s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0']
SQL RUNTIME[0.00036812s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2450' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026822s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2450' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00031304s]
.] upsEBatteryEstimatedChargeRemaining [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryEstimatedChargeRemaining]

CMD EXITCODE[0]
CMD RUNTIME[0.0373s]
STDOUT[
upsEBatteryEstimatedChargeRemaining.0 = 100
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedChargeRemaining
Discover sensor: [class: capacity, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.4.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedChargeRemaining, descr: Battery Charge Remaining, scale: 1, limits: (10, 20, , ), CURRENT: 100, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0')]
SQL RUNTIME[0.00055003s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0']
SQL RUNTIME[0.00036192s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2451' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025511s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2451' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023293s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-capacity-eppc-mib-upsEBatteryEstimatedChargeRemaining.rrd'
] upsEBatteryEstimatedMinutesRemaining [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryEstimatedMinutesRemaining]

CMD EXITCODE[0]
CMD RUNTIME[0.0385s]
STDOUT[
upsEBatteryEstimatedMinutesRemaining.0 = 293
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedMinutesRemaining
Discover sensor: [class: runtime, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.3.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedMinutesRemaining, descr: Battery Runtime Remaining, scale: 1, limits: (5, 20, , ), CURRENT: 293, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0')]
SQL RUNTIME[0.00043511s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0']
SQL RUNTIME[0.00037193s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2452' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028396s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2452' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00026608s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-runtime-eppc-mib-upsEBatteryEstimatedMinutesRemaining.0.rrd'
] upsESecondsOnBattery [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESecondsOnBattery]

CMD EXITCODE[0]
CMD RUNTIME[0.0379s]
STDOUT[
upsESecondsOnBattery.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESecondsOnBattery
Discover sensor: [class: runtime, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.2.0, index: 0, type: EPPC-MIB-upsESecondsOnBattery, descr: Battery Runtime, scale: 0.016666666666667, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0')]
SQL RUNTIME[0.00050211s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0']
SQL RUNTIME[0.00036788s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2453' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025797s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2453' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023603s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-runtime-eppc-mib-upsESecondsOnBattery.0.rrd'
] 
 o EPPC-MIB             upsESystemStatus [
CMD[/usr/bin/snmptranslate -On -Pu -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'EPPC-MIB::upsESystemStatus']

CMD EXITCODE[0]
CMD RUNTIME[0.018s]
STDOUT[
.1.3.6.1.4.1.935.10.1.1.2.1
]
SNMP TRANSLATE (CMD): 'EPPC-MIB::upsESystemStatus' -> '.1.3.6.1.4.1.935.10.1.1.2.1'

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0372s]
STDOUT[
upsESystemStatus.0 = line
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemStatus
Discover status: [device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.1.0, index: 0, type: upsESystemStatus, descr: System Status, CURRENT: 4, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00082803s]

SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00058293s]
.] upsEBatteryStatus [
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0397s]
STDOUT[
upsEBatteryStatus.0 = batteryNormal
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryStatus
Discover status: [device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.1.0, index: 0, type: upsEBatteryStatus, descr: Battery Status, CURRENT: 2, , battery]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00061798s]

SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00044203s]
.] 
 o EPPC-MIB             
CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemInputNumPhases.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0346s]
STDOUT[
1
]
SNMP STATUS[TRUE]
upsESystemInputTable (1 phases)
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemInputTable]

CMD EXITCODE[0]
CMD RUNTIME[0.1201s]
STDOUT[
upsESystemInputFrequency.1 = -1
upsESystemInputVoltage.1 = 2319
upsESystemInputCurrent.1 = -1
upsESystemInputWatts.1 = -1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigInputVoltage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0296s]
STDOUT[
-1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigInputFrequence.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0263s]
STDOUT[
-1
]
SNMP STATUS[TRUE]
Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1, index: 1, type: EPPC-MIB-upsESystemInputVoltage, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: 231.9, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1')]
SQL RUNTIME[0.00061607s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1']
SQL RUNTIME[0.00037789s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2454' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026202s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2454' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023818s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-voltage-eppc-mib-upsESystemInputVoltage.1.rrd'
Discover sensor: [class: frequency, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1, index: 1, type: EPPC-MIB-upsESystemInputFrequency, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: -0.1, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1')]
SQL RUNTIME[0.00031900s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1']
SQL RUNTIME[0.00033593s]
High/low limits swapped.

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2455' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027585s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2455' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00023603s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-frequency-eppc-mib-upsESystemInputFrequency.1.rrd'

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemOutputNumPhase.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0367s]
STDOUT[
1
]
SNMP STATUS[TRUE]
upsESystemOutputTable (1 phases)
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemOutputTable]

CMD EXITCODE[0]
CMD RUNTIME[0.1005s]
STDOUT[
upsESystemOutputFrequency.1 = 500
upsESystemOutputVoltage.1 = 2320
upsESystemOutputCurrent.1 = -1
upsESystemOutputWatts.1 = -1
upsESystemOutputVA.1 = -1
upsESystemOutputLoad.1 = 15
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputVoltage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.026s]
STDOUT[
2300
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputFrequency.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0267s]
STDOUT[
500
]
SNMP STATUS[TRUE]
Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.3., index: 1, type: EPPC-MIB-upsESystemOutputVoltage, descr: Output, scale: 0.1, limits: (195.5, 207, 253, 264.5), CURRENT: 232, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1')]
SQL RUNTIME[0.00076985s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1']
SQL RUNTIME[0.00058818s]
LCurrent sensor value: "232", scale: "0.1"
  limit_high: "264.5" -> "264.5"
  limit_high_warn: "253" -> "253"
  limit_low: "195.5" -> "195.5"
  limit_low_warn: "207" -> "207"


SQL[UPDATE `sensors` set `sensor_limit_warn` ='253' WHERE `sensor_id` = '2456']
SQL RUNTIME[0.00036097s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2456' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00048614s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2456' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00045896s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-voltage-eppc-mib-upsESystemOutputVoltage.1.rrd'
Discover sensor: [class: frequency, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.2., index: 1, type: EPPC-MIB-upsESystemOutputFrequency, descr: Output, scale: 0.1, limits: (47.5, 48.5, 51.5, 52.5), CURRENT: 50, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1')]
SQL RUNTIME[0.00060105s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1']
SQL RUNTIME[0.00052214s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2457' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00037098s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2457' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00038600s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-frequency-eppc-mib-upsESystemOutputFrequency.1.rrd'
Discover sensor: [class: load, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.7., index: 1, type: EPPC-MIB-upsESystemOutputLoad, descr: Output, scale: 1, limits: (, , 75, 90), CURRENT: 15, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1')]
SQL RUNTIME[0.00047684s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1']
SQL RUNTIME[0.00052285s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2458' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00036311s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2458' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00034404s]
.RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-load-eppc-mib-upsESystemOutputLoad.1.rrd'

CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemBypassNumPhase.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0264s]
STDOUT[
-1
]
SNMP STATUS[TRUE]

 o ENTITY-SENSOR-MIB    
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0337s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorType]

CMD EXITCODE[0]
CMD RUNTIME[0.0344s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorScale]

CMD EXITCODE[0]
CMD RUNTIME[0.0388s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorPrecision]

CMD EXITCODE[0]
CMD RUNTIME[0.0316s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0325s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorUnitsDisplay]

CMD EXITCODE[0]
CMD RUNTIME[0.0338s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.141s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalName]

CMD EXITCODE[0]
CMD RUNTIME[0.1477s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalClass]

CMD EXITCODE[0]
CMD RUNTIME[0.1294s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalContainedIn]

CMD EXITCODE[0]
CMD RUNTIME[0.1326s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalParentRelPos]

CMD EXITCODE[0]
CMD RUNTIME[0.1548s]
STDOUT[

]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entAliasMappingIdentifier]

CMD EXITCODE[0]
CMD RUNTIME[0.0458s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00095415s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00032091s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00038695s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029707s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00032306s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00073695s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00059605s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00052691s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030184s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00033092s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030613s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030804s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028992s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029707s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00044489s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00060606s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029206s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030398s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028586s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028181s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030589s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00037193s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00038886s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00037503s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029802s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028610s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029397s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029302s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028110s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028014s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00031018s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035286s]

SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00029087s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '169' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00027204s]


 o Duration             2.1299s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_storage']
SQL RUNTIME[0.00025892s]
#####  Module Start: storage  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dskEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.2201s]
STDOUT[

]
SNMP STATUS[TRUE]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0532s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `storage` WHERE `device_id` = '169']
SQL RUNTIME[0.00055385s]

 o Duration             0.2822s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_neighbours']
SQL RUNTIME[0.00032210s]
#####  Module Start: neighbours  #####

 o LLDP-MIB             
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' lldpRemChassisIdSubtype]

CMD EXITCODE[0]
CMD RUNTIME[0.0529s]
STDOUT[

]
SNMP STATUS[TRUE]

 o CISCO-CDP-MIB        
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' cdpCache]

CMD EXITCODE[0]
CMD RUNTIME[0.1162s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `neighbours` WHERE `device_id` = '169']
SQL RUNTIME[0.00050902s]



 o Duration             0.1802s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_arp-table']
SQL RUNTIME[0.00032306s]
#####  Module Start: arp-table  #####


SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '169' GROUP BY `port_id`]
SQL RUNTIME[0.00030899s]

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipNetToPhysicalPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0735s]
STDOUT[
ipNetToPhysicalPhysAddress[1] Wrong Type (should be OCTET STRING): 0
ipNetToPhysicalPhysAddress[2] Wrong Type (should be OCTET STRING): 0
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToPhysicalPhysAddress

CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipNetToMediaPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0677s]
STDOUT[
ipNetToMediaPhysAddress[2][172.21.99.152] c8:1f:66:28:f1:de
ipNetToMediaPhysAddress[2][172.21.99.254] 0:50:56:b2:94:36
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToMediaPhysAddress

SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M LEFT JOIN ports AS I ON M.port_id = I.port_id WHERE I.device_id = '169']
SQL RUNTIME[0.00063896s]
..

 o Duration             0.152s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_junose-atm-vp']
SQL RUNTIME[0.00032187s]
Module [junose-atm-vp] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_bgp-peers']
SQL RUNTIME[0.00028491s]
Module [bgp-peers] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_mac-accounting']
SQL RUNTIME[0.00027323s]
#####  Module Start: mac-accounting  #####


 o Duration             0.0006s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_sla']
SQL RUNTIME[0.00030899s]
#####  Module Start: sla  #####

 o DISMAN-PING-MIB      
CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' pingCtlEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0726s]
STDOUT[

]
SNMP STATUS[TRUE]


SQL[SELECT * FROM `slas` WHERE `device_id` = '169']
SQL RUNTIME[0.00059795s]

 o Duration             0.0776s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_lsp']
SQL RUNTIME[0.00031996s]
Module [lsp] disabled globally by config in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_pseudowires']
SQL RUNTIME[0.00027609s]
Module [pseudowires] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_virtual-machines']
SQL RUNTIME[0.00028801s]
#####  Module Start: virtual-machines  #####



 o Duration             0.0015s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_cisco-cbqos']
SQL RUNTIME[0.00029182s]
Module [cisco-cbqos] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ucd-diskio']
SQL RUNTIME[0.00029421s]
#####  Module Start: ucd-diskio  #####


CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' diskIOEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0581s]
STDOUT[

]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '169']
SQL RUNTIME[0.00030303s]


 o Duration             0.0626s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_wifi']
SQL RUNTIME[0.00027108s]
Module [wifi] disabled for device type 'power'. in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_p2p-radios']
SQL RUNTIME[0.00027704s]
Module [p2p-radios] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_graphs']
SQL RUNTIME[0.00023794s]
#####  Module Start: graphs  #####


 o Duration             0.0005s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_raid']
SQL RUNTIME[0.00025511s]
Module [raid] disabled globally by config in process [discovery].
 o Modules Excluded     vrf, junose-atm-vp, cisco-cbqos
 o Modules Disabled     ports-stack, vlans, bgp-peers, lsp, pseudowires, wifi, p2p-radios, raid
 o Modules Enabled      os, mibs, ports, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage, neighbours, 
                        arp-table,mac-accounting, sla, virtual-machines, ucd-diskio, graphs 

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '169';]
SQL RUNTIME[0.00020099s]

SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='5.2712',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";d:0.1501;s:2:\"os\";d:0.1131;s:7:\"sensors\";d:0.3201;s:6:\"status\";d:0.0423;s:7:\"counter\";d:0.0014;s:10:\"processors\";d:0.0019;s:8:\"mempools\";d:0.0012;s:7:\"storage\";d:0.0021;s:7:\"ucd-mib\";d:0.1763;s:13:\"ipSystemStats\";d:1.0497;s:5:\"ports\";d:0.8569;s:15:\"printersupplies\";d:0.001;s:10:\"ucd-diskio\";d:0.0009;s:4:\"ospf\";d:0.0001;s:3:\"sla\";d:0.0013;s:14:\"mac-accounting\";d:0.0014;s:12:\"loadbalancer\";d:0.0004;s:15:\"entity-physical\";d:0.0002;s:12:\"applications\";d:0.0016;s:9:\"fdb-table\";d:0.0842;s:6:\"graphs\";d:0.0986;s:4:\"oids\";d:0.0014;s:6:\"probes\";d:0.0012;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.45494604110717773;s:13:\"EtherLike-MIB\";d:0.03960895538330078;s:12:\"Q-BRIDGE-MIB\";d:0.15981793403625488;s:6:\"IP-MIB\";d:0.16146302223205566;}s:14:\"poller_history\";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:\"discovery_history\";a:5:{i:1676297773;d:5.2712;i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.0927;s:4:\"mibs\";d:0.2047;s:5:\"ports\";d:0.2379;s:4:\"oids\";d:0.0018;s:12:\"ip-addresses\";d:1.3725;s:10:\"processors\";d:0.0659;s:8:\"mempools\";d:0.1178;s:9:\"inventory\";d:0.2484;s:15:\"printersupplies\";d:0.0022;s:7:\"sensors\";d:2.1299;s:7:\"storage\";d:0.2822;s:10:\"neighbours\";d:0.1802;s:9:\"arp-table\";d:0.152;s:14:\"mac-accounting\";d:0.0006;s:3:\"sla\";d:0.0776;s:16:\"virtual-machines\";d:0.0015;s:10:\"ucd-diskio\";d:0.0626;s:6:\"graphs\";d:0.0005;}}' WHERE `device_id` = '169']
SQL RUNTIME[0.00218105s]
#####  172.21.99.138 [169] completed discovery modules at 2023-02-13 15:16:18  #####

 o Discovery time       5.2712 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '3572974' AND `process_name` = 'discovery.php' AND `device_id` = '169' AND `poller_id` = '0']
SQL RUNTIME[0.00114512s]
#####  Finished discovery run at 2023-02-13 15:16:18  #####


SQL[SELECT * FROM `groups` ORDER BY `entity_type`]
SQL RUNTIME[0.00021911s]

SQL[SELECT * FROM `groups_assoc`]
SQL RUNTIME[0.00017715s]

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00023293s]
Cached 5 alert rules.

SQL[SELECT * FROM `alert_assoc`]
SQL RUNTIME[0.00016809s]

SQL[SELECT `processor_id`, `devices`.`device_id` as `device_id` FROM `processors` LEFT JOIN `devices` ON (`processors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('155','78','79','140','141','147','148','142','146','80','81','82','83','84','85','138','143','145','139','70','71','72','73','74','95','75','76','77','100','69','103','156','157','158','151','152','153','159','160','149','164','167','166','168','161','163','165','150','162','154','15','57','89','10','58','59','60','61','90','62','63','64','16','65','97','9','94','66','17','18','20','67','68','3','2','19','6','11','12','1','21','13','14','22','23','24','101','25','7','91','98','26','27','28','137','5','4','29','30','86','87','31','32','99','92','33','96','34','35','36','37','38','39','42','88','43','44','45','46','93','47','48','49','50','51','52','53','54','55','56','135','133','169','132','118','119','120','121','122','123','124','125','130','126','127','128','104','107','117','116','115','106','109','108','111','110','105','113','114','112','136'))]
SQL RUNTIME[0.00184703s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '1']
SQL RUNTIME[0.00488591s]
Alert Checker                    'CPU Alert': 1040 existing, 1040 new entries (+0/-0).

SQL[SELECT `mempool_id`, `devices`.`device_id` as `device_id` FROM `mempools` LEFT JOIN `devices` ON (`mempools`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('40','78','79','140','141','142','80','81','82','83','84','85','138','143','145','139','70','71','72','73','74','95','75','76','77','100','69','103','15','57','89','10','58','59','60','61','90','62','63','64','16','65','97','9','94','66','17','18','20','67','68','3','2','19','6','11','12','1','21','13','14','22','23','24','101','25','7','91','98','26','27','28','137','5','4','29','30','86','87','31','32','99','92','33','96','34','35','36','37','38','39','42','88','43','44','45','46','93','47','48','49','50','51','52','53','54','55','56','135','133','134','132','118','119','120','121','122','123','124','125','130','126','127','128','104','107','117','116','115','106','109','108','111','110','105','113','114','112','136')) AND `mempools`.`mempool_deleted` != '1']
SQL RUNTIME[0.00121713s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '2']
SQL RUNTIME[0.00074100s]
Alert Checker                          'RAM': 45 existing, 45 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`ifType` = 'ethernetCsmacd' OR `ports`.`ifType` = 'propVirtual' OR `ports`.`ifType` = 'propPointToPointSerial' OR `ports`.`ifType` = 'other' OR `ports`.`ifType` = 'tunnel' OR `ports`.`ifType` = 'ieee8023adLag' OR `ports`.`ifType` = 'softwareLoopback' OR `ports`.`ifType` = 'fibreChannel' OR `ports`.`ifType` = 'ipForward' OR `ports`.`ifType` = 'l2vlan' OR `ports`.`ifType` = 'gigabitEthernet' OR `ports`.`ifType` = 'propMultiplexor') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.01349998s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '3']
SQL RUNTIME[0.02352500s]
Alert Checker          'Traffic exceeds 80%': 5717 existing, 5717 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%')]
SQL RUNTIME[0.00074410s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '5']
SQL RUNTIME[0.00165486s]
Alert Checker                  'Device down': 161 existing, 161 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( `sensors`.`sensor_class` = 'temperature') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00634003s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '6']
SQL RUNTIME[0.00507712s]
Alert Checker 'Temperature is higher then 75 degrees': 567 existing, 567 new entries (+0/-0).
./discovery.php: 172.21.99.138 - 1 devices discovered in 5.494 secs

SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1676283372']
SQL RUNTIME[0.00027299s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       5.494 secs
 o Memory usage         40MB (peak: 40MB)
 o MySQL Usage          Cell[23/0.029s] Row[68/0.071s] Rows[77/0.206s] Column[2/0.002s] Update[2/0.004s] Insert[1/0.002s] Delete[2/0.003s] 
 o RRDTool Usage