DEBUG! CMD[/usr/bin/svn info /opt/observium]  CMD EXITCODE[0] CMD RUNTIME[0.0155s] CMD EXITDELAY[10ms] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: https://svn.observium.org/svn/observium/branches/stable Relative URL: ^/observium/branches/stable Repository Root: https://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 12523 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 12520 Last Changed Date: 2023-02-08 20:28:14 +0100 (Wed, 08 Feb 2023) ] DEFINITIONS loaded by: 0.15485 ms DEFINITIONS in memory: 15.4MB SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00025296s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00014210s]  SQL[SET SESSION `sql_mode` = 'NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00012183s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00013113s]  SQL[SELECT * FROM `config`] SQL RUNTIME[0.00021005s]  CMD[/bin/hostname -f]  CMD EXITCODE[0] CMD RUNTIME[0.003s] STDOUT[ vm-observium ] SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)] SQL RUNTIME[0.00031710s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00022578s]  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 23.2.12520 https://www.observium.org   CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.022s] STDOUT[ Linux|5.15.0-58-generic|amd64|Ubuntu|20.04|vmware| ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0035s] STDOUT[ Python 3.8.10 ] SQL[SELECT version();] SQL RUNTIME[0.00023413s]  CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0036s] STDOUT[ NET-SNMP version: 5.8 ] CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0099s] CMD EXITDELAY[10ms] STDOUT[ RRDtool 1.7.2 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0025s] STDOUT[ /usr/bin/fping: Version 4.2 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0444s] STDOUT[ Apache/2.4.41 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00023603s]  SQL[SHOW VARIABLES LIKE 'log_bin'] SQL RUNTIME[0.04011703s]  SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00188708s]  ##### Software versions #####   o OS  Linux 5.15.0-58-generic [amd64] (Ubuntu 20.04)  o Apache  2.4.41  o PHP  7.4.3-4ubuntu2.17 (OPcache: DISABLED)  o Python  3.8.10  o MySQL  8.0.32-0ubuntu0.20.04.2 (extension: mysqli 7.4.3-4ubuntu2.17)  o SNMP  NET-SNMP 5.8  o RRDtool  1.7.2  o Fping  4.2 (IPv4 and IPv6) ##### Memory Limit #####   o PHP  Unlimited ##### DB info #####   o DB schema  478  o MySQL binlog  ON  o MySQL mode  NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MySQL  utf8mb3 ##### Timezones info #####   o Date  Monday, 13-Feb-23 15:16:13 CET  o PHP  +01:00  o MySQL  +01:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00026679s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00017905s] ##### Starting discovery run at 2023-02-13 15:16:13 #####   SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `device_id` = '169' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00035882s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.0574s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.935.10.1 .1.3.6.1.2.1.1.3.0 = 0:1:33:21.44 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169'] SQL RUNTIME[0.00043488s]  SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '169' AND `poller_id` = '0'] SQL RUNTIME[0.00027585s]  SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('3572974','discovery.php','3402670','0','php ./discovery.php -d -h 169','1676297773','169')] SQL RUNTIME[0.00173593s] ##### 172.21.99.138 [169] #####   o OS Type  eppc-ups  o OS Group  ups  o SNMP Version  v1  o Last discovery  2023-02-13 15:10:16  o Last duration  4.91 seconds ##### Module Start: os #####   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0288s] STDOUT[ Network Management Card for UPS ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0275s] STDOUT[ .1.3.6.1.4.1.935.10.1 ] SNMP STATUS[TRUE] +-------------+---------------------------------+ | OID | | +-------------+---------------------------------+ | sysDescr | Network Management Card for UPS | | sysObjectID | .1.3.6.1.4.1.935.10.1 | +-------------+---------------------------------+  o Detect OS matched (eppc-ups: EPPC UPS):  +-------------+-----------------------+-----------------------+ | OID | Matched definition | | +-------------+-----------------------+-----------------------+ | sysObjectID | .1.3.6.1.4.1.935.10.1 | .1.3.6.1.4.1.935.10.1 | +-------------+-----------------------+-----------------------+  o Duration  0.0927s ##### Module Start: mibs #####   CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']  CMD EXITCODE[0] CMD RUNTIME[0.0151s] STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' .1.3.6.1.2.1.1.9.1.2]  CMD EXITCODE[0] CMD RUNTIME[0.063s] STDOUT[ .1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1 .1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.10.3.1.1 .1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.6.3.11.3.1.1 .1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.6.3.15.2.1.1 .1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.6.3.16.2.1.1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' sysORDescr]  CMD EXITCODE[0] CMD RUNTIME[0.077s] STDOUT[ sysORDescr.1 = The MIB Module from SNMPv2 entities sysORDescr.2 = SNMP Management Architecture MIB sysORDescr.3 = Message Processing and Dispatching MIB sysORDescr.4 = USM User MIB sysORDescr.5 = VACM MIB ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m OSPFV3-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ospfv3AdminStatus.0]  CMD EXITCODE[2] CMD RUNTIME[0.0311s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: OSPFV3-MIB::ospfv3AdminStatus.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: OSPFV3-MIB::ospfv3AdminStatus.0  o MIBs discovered   SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00042295s]  +-----------------------+--------------------+---------+---------------------+ | Identity | MIB | Source | Status | +-----------------------+--------------------+---------+---------------------+ | .1.3.6.1.6.3.1 | SNMPv2-MIB | sysORID | MIB already defined | | .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined | | .1.3.6.1.6.3.11.3.1.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.15.2.1.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.16.2.1.1 | - | sysORID | Unknown Identity | +-----------------------+--------------------+---------+---------------------+ SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00034595s] JSON DECODE[Not string passed] JSON RAW[  > $str /opt/observium/includes/common.inc.php:5437  null ] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '169' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00024915s]    /opt/observium/includes/discovery/mibs.inc.php:313  array( [0] => string(8) "EPPC-MIB" [1] => string(10) "SNMPv2-MIB" [2] => string(18) "SNMP-FRAMEWORK-MIB" [3] => string(6) "IF-MIB" [4] => string(13) "ADSL-LINE-MIB" [5] => string(13) "EtherLike-MIB" [6] => string(10) "ENTITY-MIB" [7] => string(17) "ENTITY-SENSOR-MIB" [8] => string(12) "UCD-SNMP-MIB" [9] => string(18) "HOST-RESOURCES-MIB" [10] => string(12) "Q-BRIDGE-MIB" [11] => string(6) "IP-MIB" [12] => string(8) "IPV6-MIB" [13] => string(8) "LLDP-MIB" [14] => string(13) "CISCO-CDP-MIB" [15] => string(15) "DISMAN-PING-MIB" )  o Duration  0.2047s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_vrf'] SQL RUNTIME[0.00025010s] Module [vrf] blacklisted by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ports'] SQL RUNTIME[0.00024080s] ##### Module Start: ports #####   o Caching OIDs  ifDescr CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifDescr]  CMD EXITCODE[0] CMD RUNTIME[0.046s] STDOUT[ ifDescr.1 = lo ifDescr.2 = eth0 ] SNMP STATUS[TRUE] ifAlias CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifAlias]  CMD EXITCODE[0] CMD RUNTIME[0.0357s] STDOUT[ ] SNMP STATUS[TRUE] ifName CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifName]  CMD EXITCODE[0] CMD RUNTIME[0.0333s] STDOUT[ ] SNMP STATUS[TRUE] ifType CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifType]  CMD EXITCODE[0] CMD RUNTIME[0.0442s] STDOUT[ ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ] SNMP STATUS[TRUE] ifOperStatus CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ifOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0636s] STDOUT[ ifOperStatus.1 = up ifOperStatus.2 = up ] SNMP STATUS[TRUE]    /opt/observium/includes/discovery/ports.inc.php:44  array( [1] => array( [ifDescr] => string(2) "lo" [ifType] => string(16) "softwareLoopback" [ifOperStatus] => string(2) "up" ) [2] => array( [ifDescr] => string(4) "eth0" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) )  o Caching DB   SQL[SELECT * FROM `ports` WHERE `device_id` = '169'] SQL RUNTIME[0.00065207s] 2 ports  o Discovering ports  .. +---------+---------+--------+---------+------------------+-------------+---------+ | ifIndex | ifDescr | ifName | ifAlias | ifType | Oper Status | Ignored | +---------+---------+--------+---------+------------------+-------------+---------+ | 1 | lo | | ... | softwareLoopback | up | no | | 2 | eth0 | | ... | ethernetCsmacd | up | no | +---------+---------+--------+---------+------------------+-------------+---------+  o Duration  0.2379s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ports-stack'] SQL RUNTIME[0.00035286s] Module [ports-stack] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_vlans'] SQL RUNTIME[0.00026798s] Module [vlans] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_oids'] SQL RUNTIME[0.00029707s] ##### Module Start: oids #####   SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '169'] SQL RUNTIME[0.00032115s]  SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1'] SQL RUNTIME[0.00022507s]   o Duration  0.0018s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ip-addresses'] SQL RUNTIME[0.00025201s] ##### Module Start: ip-addresses #####   SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00024199s] JSON DECODE[Not string passed] JSON RAW[   /opt/observium/includes/common.inc.php:5437  null ]  o IP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAdEntIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0486s] STDOUT[ ipAdEntIfIndex.127.0.0.1 = 1 ipAdEntIfIndex.172.21.99.138 = 2 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAdEntNetMask]  CMD EXITCODE[0] CMD RUNTIME[0.0489s] STDOUT[ ipAdEntNetMask.127.0.0.1 = 255.255.255.255 ipAdEntNetMask.172.21.99.138 = 255.255.255.0 ] SNMP STATUS[TRUE] Added 127.0.0.1 .Added 172.21.99.138 . CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0388s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressType]  CMD EXITCODE[0] CMD RUNTIME[0.0508s] STDOUT[ ipAddressType.ipv6.".".172.21.99.152 = "C8 1F 66 28 F1 DE " ipAddressType.ipv6.".".172.21.99.254 = "00 50 56 B2 94 36 " ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressPrefix]  CMD EXITCODE[0] CMD RUNTIME[0.0509s] STDOUT[ ipAddressPrefix.ipv6.".".172.21.99.152 = 0:0:00:00.00 ipAddressPrefix.ipv6.".".172.21.99.254 = 0:0:00:00.00 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipAddressOrigin]  CMD EXITCODE[0] CMD RUNTIME[0.0547s] STDOUT[ ipAddressOrigin.ipv6.".".172.21.99.152 = 3 ipAddressOrigin.ipv6.".".172.21.99.254 = 3 ] SNMP STATUS[TRUE] Unknown IP index: ..172.21.99.152 Unknown IP index: ..172.21.99.254  o IPV6-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipv6AddrEntry]  CMD EXITCODE[0] CMD RUNTIME[1.0363s] STDOUT[ ] SNMP STATUS[TRUE]   o LLDP-MIB   SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '169'] SQL RUNTIME[0.00040722s]  SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '169' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00027800s]  SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7725'] SQL RUNTIME[0.00033498s]  SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '169'] SQL RUNTIME[0.00036502s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7725'] SQL RUNTIME[0.00041199s]  SQL[SELECT * FROM `devices` WHERE `device_id` = '169'] SQL RUNTIME[0.00031400s]  SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '169'] SQL RUNTIME[0.00035000s]  SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'] SQL RUNTIME[0.00025511s]  SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '169' AND `ifIndex` = '2' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00026011s]  SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '7726'] SQL RUNTIME[0.00031495s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '7726'] SQL RUNTIME[0.00027609s]  SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.21.99.0/24'] SQL RUNTIME[0.00024295s]  SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '169'] SQL RUNTIME[0.00031495s]  SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '169'] SQL RUNTIME[0.00028181s] +---------+---------+-------------+------------------+----------------+----------+--------+ | ifIndex | ifDescr | IP: Version | Address | Network | Type | Origin | +---------+---------+-------------+------------------+----------------+----------+--------+ | 1 | lo | IPv4 | 127.0.0.1/32 | 127.0.0.1/32 | loopback | | | 2 | eth0 | IPv4 | 172.21.99.138/24 | 172.21.99.0/24 | private | | +---------+---------+-------------+------------------+----------------+----------+--------+  o Changes  2 unchanged  o Duration  1.3725s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_processors'] SQL RUNTIME[0.00027299s] ##### Module Start: processors #####   o UCD-SNMP-MIB   SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '169' AND `processor_type` != 'ucd-old')] SQL RUNTIME[0.00029993s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ssCpuIdle.0]  CMD EXITCODE[2] CMD RUNTIME[0.024s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: UCD-SNMP-MIB::ssCpuIdle.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrProcessorLoad]  CMD EXITCODE[0] CMD RUNTIME[0.0342s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `processors` WHERE `device_id` = '169'] SQL RUNTIME[0.00056911s]   o Duration  0.0659s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_mempools'] SQL RUNTIME[0.00032997s] ##### Module Start: mempools #####   o UCD-SNMP-MIB   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]  CMD EXITCODE[2] CMD RUNTIME[0.0709s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memBuffer.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memCached.0 ] SNMP ERROR[#1000 - Failed response] SNMP ERROR[#1000 - Failed response] SNMP STATUS[FALSE]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrStorageEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0395s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `mempools` WHERE `device_id` = '169'] SQL RUNTIME[0.00047493s]   o Duration  0.1178s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_inventory'] SQL RUNTIME[0.00041318s] ##### Module Start: inventory #####   o ENTITY-MIB  ENTITY-MIB CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalEntry]  CMD EXITCODE[0] CMD RUNTIME[0.1281s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entAliasMappingIdentifier]  CMD EXITCODE[0] CMD RUNTIME[0.0355s] STDOUT[ ] SNMP STATUS[TRUE]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrDeviceEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0359s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrProcessorEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0361s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '169'] SQL RUNTIME[0.00043893s]  SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '169'] SQL RUNTIME[0.00028300s]   o Duration  0.2484s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_printersupplies'] SQL RUNTIME[0.00031590s] ##### Module Start: printersupplies #####   SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '169'] SQL RUNTIME[0.00025988s]   o Duration  0.0022s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_sensors'] SQL RUNTIME[0.00028014s] ##### Module Start: sensors #####   o EPPC-MIB  upsESystemTemperature [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemTemperature]  CMD EXITCODE[0] CMD RUNTIME[0.0358s] STDOUT[ upsESystemTemperature.0 = 236 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsESystemTemperature CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOverTemperatureSetPoint]  CMD EXITCODE[0] CMD RUNTIME[0.0351s] STDOUT[ upsESystemConfigOverTemperatureSetPoint.0 = 900 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsESystemConfigOverTemperatureSetPoint Discover sensor: [class: temperature, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.2.0, index: 0, type: EPPC-MIB-upsESystemTemperature, descr: System, scale: 0.1, limits: (, , , 90), CURRENT: 23.6, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0')] SQL RUNTIME[0.00060010s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0'] SQL RUNTIME[0.00037599s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2449' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00027990s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2449' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023580s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-temperature-eppc-mib-upsESystemTemperature.rrd' ] upsEEnvironmentCurrentTemperature [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentCurrentTemperature]  CMD EXITCODE[0] CMD RUNTIME[0.0374s] STDOUT[ upsEEnvironmentCurrentTemperature.0 = -1 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentTemperature CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentTemperatureLowSetPoint]  CMD EXITCODE[0] CMD RUNTIME[0.0408s] STDOUT[ upsEEnvironmentTemperatureLowSetPoint.0 = 150 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureLowSetPoint CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentTemperatureHighSetPoint]  CMD EXITCODE[0] CMD RUNTIME[0.0373s] STDOUT[ upsEEnvironmentTemperatureHighSetPoint.0 = 500 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureHighSetPoint Excluded by current value (-1) in invalid range [-1]. ] upsEEnvironmentCurrentHumidity [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentCurrentHumidity]  CMD EXITCODE[0] CMD RUNTIME[0.0395s] STDOUT[ upsEEnvironmentCurrentHumidity.0 = -1 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentHumidity CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentHumidityLowSetPoint]  CMD EXITCODE[0] CMD RUNTIME[0.0387s] STDOUT[ upsEEnvironmentHumidityLowSetPoint.0 = 50 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityLowSetPoint CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEEnvironmentHumidityHighSetPoint]  CMD EXITCODE[0] CMD RUNTIME[0.0382s] STDOUT[ upsEEnvironmentHumidityHighSetPoint.0 = 90 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityHighSetPoint Excluded by current value (-1) in invalid range [-1]. ] upsEPositiveBatteryVoltage [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEPositiveBatteryVoltage]  CMD EXITCODE[0] CMD RUNTIME[0.0535s] STDOUT[ upsEPositiveBatteryVoltage.0 = 814 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEPositiveBatteryVoltage Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.5.0, index: 0, type: EPPC-MIB-upsEPositiveBatteryVoltage, descr: Battery, scale: 0.1, limits: (, , , ), CURRENT: 81.4, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00042200s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00036812s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2450' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00026822s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2450' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00031304s] .] upsEBatteryEstimatedChargeRemaining [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryEstimatedChargeRemaining]  CMD EXITCODE[0] CMD RUNTIME[0.0373s] STDOUT[ upsEBatteryEstimatedChargeRemaining.0 = 100 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedChargeRemaining Discover sensor: [class: capacity, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.4.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedChargeRemaining, descr: Battery Charge Remaining, scale: 1, limits: (10, 20, , ), CURRENT: 100, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0')] SQL RUNTIME[0.00055003s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0'] SQL RUNTIME[0.00036192s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2451' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00025511s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2451' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023293s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-capacity-eppc-mib-upsEBatteryEstimatedChargeRemaining.rrd' ] upsEBatteryEstimatedMinutesRemaining [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryEstimatedMinutesRemaining]  CMD EXITCODE[0] CMD RUNTIME[0.0385s] STDOUT[ upsEBatteryEstimatedMinutesRemaining.0 = 293 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedMinutesRemaining Discover sensor: [class: runtime, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.3.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedMinutesRemaining, descr: Battery Runtime Remaining, scale: 1, limits: (5, 20, , ), CURRENT: 293, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0')] SQL RUNTIME[0.00043511s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0'] SQL RUNTIME[0.00037193s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2452' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00028396s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2452' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00026608s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-runtime-eppc-mib-upsEBatteryEstimatedMinutesRemaining.0.rrd' ] upsESecondsOnBattery [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESecondsOnBattery]  CMD EXITCODE[0] CMD RUNTIME[0.0379s] STDOUT[ upsESecondsOnBattery.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsESecondsOnBattery Discover sensor: [class: runtime, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.2.0, index: 0, type: EPPC-MIB-upsESecondsOnBattery, descr: Battery Runtime, scale: 0.016666666666667, limits: (, , , ), CURRENT: 0, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0')] SQL RUNTIME[0.00050211s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0'] SQL RUNTIME[0.00036788s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2453' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00025797s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2453' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023603s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-runtime-eppc-mib-upsESecondsOnBattery.0.rrd' ]  o EPPC-MIB  upsESystemStatus [ CMD[/usr/bin/snmptranslate -On -Pu -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'EPPC-MIB::upsESystemStatus']  CMD EXITCODE[0] CMD RUNTIME[0.018s] STDOUT[ .1.3.6.1.4.1.935.10.1.1.2.1 ] SNMP TRANSLATE (CMD): 'EPPC-MIB::upsESystemStatus' -> '.1.3.6.1.4.1.935.10.1.1.2.1' CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0372s] STDOUT[ upsESystemStatus.0 = line ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsESystemStatus Discover status: [device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.1.0, index: 0, type: upsESystemStatus, descr: System Status, CURRENT: 4, , device] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00082803s]  SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00058293s] .] upsEBatteryStatus [ CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsEBatteryStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0397s] STDOUT[ upsEBatteryStatus.0 = batteryNormal ] SNMP STATUS[TRUE] Store in cache Table OID: EPPC-MIB::upsEBatteryStatus Discover status: [device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.3.1.0, index: 0, type: upsEBatteryStatus, descr: Battery Status, CURRENT: 2, , battery] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00061798s]  SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00044203s] .]  o EPPC-MIB   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemInputNumPhases.0]  CMD EXITCODE[0] CMD RUNTIME[0.0346s] STDOUT[ 1 ] SNMP STATUS[TRUE] upsESystemInputTable (1 phases) CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemInputTable]  CMD EXITCODE[0] CMD RUNTIME[0.1201s] STDOUT[ upsESystemInputFrequency.1 = -1 upsESystemInputVoltage.1 = 2319 upsESystemInputCurrent.1 = -1 upsESystemInputWatts.1 = -1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigInputVoltage.0]  CMD EXITCODE[0] CMD RUNTIME[0.0296s] STDOUT[ -1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigInputFrequence.0]  CMD EXITCODE[0] CMD RUNTIME[0.0263s] STDOUT[ -1 ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1, index: 1, type: EPPC-MIB-upsESystemInputVoltage, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: 231.9, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1')] SQL RUNTIME[0.00061607s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1'] SQL RUNTIME[0.00037789s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2454' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00026202s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2454' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023818s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-voltage-eppc-mib-upsESystemInputVoltage.1.rrd' Discover sensor: [class: frequency, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1, index: 1, type: EPPC-MIB-upsESystemInputFrequency, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: -0.1, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1')] SQL RUNTIME[0.00031900s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1'] SQL RUNTIME[0.00033593s] High/low limits swapped. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2455' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00027585s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2455' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00023603s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-frequency-eppc-mib-upsESystemInputFrequency.1.rrd' CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemOutputNumPhase.0]  CMD EXITCODE[0] CMD RUNTIME[0.0367s] STDOUT[ 1 ] SNMP STATUS[TRUE] upsESystemOutputTable (1 phases) CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemOutputTable]  CMD EXITCODE[0] CMD RUNTIME[0.1005s] STDOUT[ upsESystemOutputFrequency.1 = 500 upsESystemOutputVoltage.1 = 2320 upsESystemOutputCurrent.1 = -1 upsESystemOutputWatts.1 = -1 upsESystemOutputVA.1 = -1 upsESystemOutputLoad.1 = 15 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputVoltage.0]  CMD EXITCODE[0] CMD RUNTIME[0.026s] STDOUT[ 2300 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemConfigOutputFrequency.0]  CMD EXITCODE[0] CMD RUNTIME[0.0267s] STDOUT[ 500 ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.3., index: 1, type: EPPC-MIB-upsESystemOutputVoltage, descr: Output, scale: 0.1, limits: (195.5, 207, 253, 264.5), CURRENT: 232, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1')] SQL RUNTIME[0.00076985s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1'] SQL RUNTIME[0.00058818s] LCurrent sensor value: "232", scale: "0.1" limit_high: "264.5" -> "264.5" limit_high_warn: "253" -> "253" limit_low: "195.5" -> "195.5" limit_low_warn: "207" -> "207" SQL[UPDATE `sensors` set `sensor_limit_warn` ='253' WHERE `sensor_id` = '2456'] SQL RUNTIME[0.00036097s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2456' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00048614s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2456' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00045896s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-voltage-eppc-mib-upsESystemOutputVoltage.1.rrd' Discover sensor: [class: frequency, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.2., index: 1, type: EPPC-MIB-upsESystemOutputFrequency, descr: Output, scale: 0.1, limits: (47.5, 48.5, 51.5, 52.5), CURRENT: 50, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1')] SQL RUNTIME[0.00060105s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1'] SQL RUNTIME[0.00052214s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2457' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00037098s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2457' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00038600s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-frequency-eppc-mib-upsESystemOutputFrequency.1.rrd' Discover sensor: [class: load, device: 172.21.99.138, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.7., index: 1, type: EPPC-MIB-upsESystemOutputLoad, descr: Output, scale: 1, limits: (, , 75, 90), CURRENT: 15, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1')] SQL RUNTIME[0.00047684s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '169' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1'] SQL RUNTIME[0.00052285s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2458' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00036311s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '2458' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00034404s] .RRD old file not found: '/opt/observium/rrd/172.21.99.138/sensor-load-eppc-mib-upsESystemOutputLoad.1.rrd' CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'172.21.99.138':'161' upsESystemBypassNumPhase.0]  CMD EXITCODE[0] CMD RUNTIME[0.0264s] STDOUT[ -1 ] SNMP STATUS[TRUE]   o ENTITY-SENSOR-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorValue]  CMD EXITCODE[0] CMD RUNTIME[0.0337s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorType]  CMD EXITCODE[0] CMD RUNTIME[0.0344s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorScale]  CMD EXITCODE[0] CMD RUNTIME[0.0388s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorPrecision]  CMD EXITCODE[0] CMD RUNTIME[0.0316s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0325s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entPhySensorUnitsDisplay]  CMD EXITCODE[0] CMD RUNTIME[0.0338s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalDescr]  CMD EXITCODE[0] CMD RUNTIME[0.141s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalName]  CMD EXITCODE[0] CMD RUNTIME[0.1477s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalClass]  CMD EXITCODE[0] CMD RUNTIME[0.1294s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalContainedIn]  CMD EXITCODE[0] CMD RUNTIME[0.1326s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' entPhysicalParentRelPos]  CMD EXITCODE[0] CMD RUNTIME[0.1548s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' entAliasMappingIdentifier]  CMD EXITCODE[0] CMD RUNTIME[0.0458s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00095415s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00032091s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00038695s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029707s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00032306s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00073695s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00059605s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00052691s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030184s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033092s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030613s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030804s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028992s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029707s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00044489s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00060606s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029206s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030398s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028586s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028181s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030589s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00037193s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00038886s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00037503s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029802s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028610s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029397s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029302s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028110s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028014s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00031018s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '169' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00035286s]  SQL[SELECT * FROM `status` WHERE `device_id` = '169' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00029087s]  SQL[SELECT * FROM `counters` WHERE `device_id` = '169' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'] SQL RUNTIME[0.00027204s]   o Duration  2.1299s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_storage'] SQL RUNTIME[0.00025892s] ##### Module Start: storage #####   o UCD-SNMP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' dskEntry]  CMD EXITCODE[0] CMD RUNTIME[0.2201s] STDOUT[ ] SNMP STATUS[TRUE]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' hrStorageEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0532s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `storage` WHERE `device_id` = '169'] SQL RUNTIME[0.00055385s]   o Duration  0.2822s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_neighbours'] SQL RUNTIME[0.00032210s] ##### Module Start: neighbours #####   o LLDP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' lldpRemChassisIdSubtype]  CMD EXITCODE[0] CMD RUNTIME[0.0529s] STDOUT[ ] SNMP STATUS[TRUE]   o CISCO-CDP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'172.21.99.138':'161' cdpCache]  CMD EXITCODE[0] CMD RUNTIME[0.1162s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `neighbours` WHERE `device_id` = '169'] SQL RUNTIME[0.00050902s]   o Duration  0.1802s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_arp-table'] SQL RUNTIME[0.00032306s] ##### Module Start: arp-table #####   SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '169' GROUP BY `port_id`] SQL RUNTIME[0.00030899s]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipNetToPhysicalPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0735s] STDOUT[ ipNetToPhysicalPhysAddress[1] Wrong Type (should be OCTET STRING): 0 ipNetToPhysicalPhysAddress[2] Wrong Type (should be OCTET STRING): 0 ] SNMP STATUS[TRUE] Used IP-MIB::ipNetToPhysicalPhysAddress CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' ipNetToMediaPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0677s] STDOUT[ ipNetToMediaPhysAddress[2][172.21.99.152] c8:1f:66:28:f1:de ipNetToMediaPhysAddress[2][172.21.99.254] 0:50:56:b2:94:36 ] SNMP STATUS[TRUE] Used IP-MIB::ipNetToMediaPhysAddress SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M LEFT JOIN ports AS I ON M.port_id = I.port_id WHERE I.device_id = '169'] SQL RUNTIME[0.00063896s] ..  o Duration  0.152s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_junose-atm-vp'] SQL RUNTIME[0.00032187s] Module [junose-atm-vp] blacklisted by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_bgp-peers'] SQL RUNTIME[0.00028491s] Module [bgp-peers] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_mac-accounting'] SQL RUNTIME[0.00027323s] ##### Module Start: mac-accounting #####    o Duration  0.0006s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_sla'] SQL RUNTIME[0.00030899s] ##### Module Start: sla #####   o DISMAN-PING-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' pingCtlEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0726s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `slas` WHERE `device_id` = '169'] SQL RUNTIME[0.00059795s]   o Duration  0.0776s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_lsp'] SQL RUNTIME[0.00031996s] Module [lsp] disabled globally by config in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_pseudowires'] SQL RUNTIME[0.00027609s] Module [pseudowires] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_virtual-machines'] SQL RUNTIME[0.00028801s] ##### Module Start: virtual-machines #####    o Duration  0.0015s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_cisco-cbqos'] SQL RUNTIME[0.00029182s] Module [cisco-cbqos] blacklisted by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_ucd-diskio'] SQL RUNTIME[0.00029421s] ##### Module Start: ucd-diskio #####   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'172.21.99.138':'161' diskIOEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0581s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '169'] SQL RUNTIME[0.00030303s]   o Duration  0.0626s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_wifi'] SQL RUNTIME[0.00027108s] Module [wifi] disabled for device type 'power'. in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_p2p-radios'] SQL RUNTIME[0.00027704s] Module [p2p-radios] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_graphs'] SQL RUNTIME[0.00023794s] ##### Module Start: graphs #####    o Duration  0.0005s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '169' AND `attrib_type` = 'discover_raid'] SQL RUNTIME[0.00025511s] Module [raid] disabled globally by config in process [discovery].  o Modules Excluded  vrf, junose-atm-vp, cisco-cbqos  o Modules Disabled  ports-stack, vlans, bgp-peers, lsp, pseudowires, wifi, p2p-radios, raid  o Modules Enabled  os, mibs, ports, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage, neighbours, arp-table,mac-accounting, sla, virtual-machines, ucd-diskio, graphs SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '169';] SQL RUNTIME[0.00020099s]  SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='5.2712',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";d:0.1501;s:2:\"os\";d:0.1131;s:7:\"sensors\";d:0.3201;s:6:\"status\";d:0.0423;s:7:\"counter\";d:0.0014;s:10:\"processors\";d:0.0019;s:8:\"mempools\";d:0.0012;s:7:\"storage\";d:0.0021;s:7:\"ucd-mib\";d:0.1763;s:13:\"ipSystemStats\";d:1.0497;s:5:\"ports\";d:0.8569;s:15:\"printersupplies\";d:0.001;s:10:\"ucd-diskio\";d:0.0009;s:4:\"ospf\";d:0.0001;s:3:\"sla\";d:0.0013;s:14:\"mac-accounting\";d:0.0014;s:12:\"loadbalancer\";d:0.0004;s:15:\"entity-physical\";d:0.0002;s:12:\"applications\";d:0.0016;s:9:\"fdb-table\";d:0.0842;s:6:\"graphs\";d:0.0986;s:4:\"oids\";d:0.0014;s:6:\"probes\";d:0.0012;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.45494604110717773;s:13:\"EtherLike-MIB\";d:0.03960895538330078;s:12:\"Q-BRIDGE-MIB\";d:0.15981793403625488;s:6:\"IP-MIB\";d:0.16146302223205566;}s:14:\"poller_history\";a:43:{i:1676297743;d:2.987;i:1676297541;d:4.0877;i:1676297529;d:2.9659;i:1676297446;d:4.8773;i:1676297241;d:4.4154;i:1676296944;d:3.0834;i:1676296640;d:4.3506;i:1676296323;d:3.974;i:1676296035;d:6.8434;i:1676295736;d:3.1523;i:1676295443;d:4.1184;i:1676295146;d:3.8055;i:1676294918;d:4.2107;i:1676294702;d:14.5392;i:1676294247;d:31.1521;i:1676293966;d:4.034;i:1676293669;d:5.2448;i:1676293329;d:4.9891;i:1676293022;d:4.7648;i:1676292735;d:5.0855;i:1676292434;d:6.0032;i:1676292045;d:5.2826;i:1676291831;d:18.3038;i:1676291530;d:2.9532;i:1676291241;d:4.1964;i:1676290936;d:5.4246;i:1676290648;d:4.5852;i:1676290338;d:3.2124;i:1676290045;d:5.7952;i:1676289739;d:3.3073;i:1676289439;d:5.6313;i:1676289131;d:5.8825;i:1676288531;d:5.6375;i:1676288241;d:5.8909;i:1676287928;d:2.9347;i:1676287629;d:2.9493;i:1676287332;d:2.9519;i:1676287028;d:2.967;i:1676286730;d:4.8366;i:1676286426;d:4.1233;i:1676286133;d:3.9831;i:1676285816;d:2.8164;i:1676285541;d:5.3201;}s:17:\"discovery_history\";a:5:{i:1676297773;d:5.2712;i:1676297411;d:4.9061;i:1676293697;d:4.2518;i:1676291179;d:5.9619;i:1676285401;d:4.1294;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.0927;s:4:\"mibs\";d:0.2047;s:5:\"ports\";d:0.2379;s:4:\"oids\";d:0.0018;s:12:\"ip-addresses\";d:1.3725;s:10:\"processors\";d:0.0659;s:8:\"mempools\";d:0.1178;s:9:\"inventory\";d:0.2484;s:15:\"printersupplies\";d:0.0022;s:7:\"sensors\";d:2.1299;s:7:\"storage\";d:0.2822;s:10:\"neighbours\";d:0.1802;s:9:\"arp-table\";d:0.152;s:14:\"mac-accounting\";d:0.0006;s:3:\"sla\";d:0.0776;s:16:\"virtual-machines\";d:0.0015;s:10:\"ucd-diskio\";d:0.0626;s:6:\"graphs\";d:0.0005;}}' WHERE `device_id` = '169'] SQL RUNTIME[0.00218105s] ##### 172.21.99.138 [169] completed discovery modules at 2023-02-13 15:16:18 #####   o Discovery time  5.2712 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '3572974' AND `process_name` = 'discovery.php' AND `device_id` = '169' AND `poller_id` = '0'] SQL RUNTIME[0.00114512s] ##### Finished discovery run at 2023-02-13 15:16:18 #####   SQL[SELECT * FROM `groups` ORDER BY `entity_type`] SQL RUNTIME[0.00021911s]  SQL[SELECT * FROM `groups_assoc`] SQL RUNTIME[0.00017715s]  SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00023293s] Cached 5 alert rules. SQL[SELECT * FROM `alert_assoc`] SQL RUNTIME[0.00016809s]  SQL[SELECT `processor_id`, `devices`.`device_id` as `device_id` FROM `processors` LEFT JOIN `devices` ON (`processors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('155','78','79','140','141','147','148','142','146','80','81','82','83','84','85','138','143','145','139','70','71','72','73','74','95','75','76','77','100','69','103','156','157','158','151','152','153','159','160','149','164','167','166','168','161','163','165','150','162','154','15','57','89','10','58','59','60','61','90','62','63','64','16','65','97','9','94','66','17','18','20','67','68','3','2','19','6','11','12','1','21','13','14','22','23','24','101','25','7','91','98','26','27','28','137','5','4','29','30','86','87','31','32','99','92','33','96','34','35','36','37','38','39','42','88','43','44','45','46','93','47','48','49','50','51','52','53','54','55','56','135','133','169','132','118','119','120','121','122','123','124','125','130','126','127','128','104','107','117','116','115','106','109','108','111','110','105','113','114','112','136'))] SQL RUNTIME[0.00184703s]  SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '1'] SQL RUNTIME[0.00488591s] Alert Checker 'CPU Alert': 1040 existing, 1040 new entries (+0/-0). SQL[SELECT `mempool_id`, `devices`.`device_id` as `device_id` FROM `mempools` LEFT JOIN `devices` ON (`mempools`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`devices`.`device_id`, '') IN ('40','78','79','140','141','142','80','81','82','83','84','85','138','143','145','139','70','71','72','73','74','95','75','76','77','100','69','103','15','57','89','10','58','59','60','61','90','62','63','64','16','65','97','9','94','66','17','18','20','67','68','3','2','19','6','11','12','1','21','13','14','22','23','24','101','25','7','91','98','26','27','28','137','5','4','29','30','86','87','31','32','99','92','33','96','34','35','36','37','38','39','42','88','43','44','45','46','93','47','48','49','50','51','52','53','54','55','56','135','133','134','132','118','119','120','121','122','123','124','125','130','126','127','128','104','107','117','116','115','106','109','108','111','110','105','113','114','112','136')) AND `mempools`.`mempool_deleted` != '1'] SQL RUNTIME[0.00121713s]  SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '2'] SQL RUNTIME[0.00074100s] Alert Checker 'RAM': 45 existing, 45 new entries (+0/-0). SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`ifType` = 'ethernetCsmacd' OR `ports`.`ifType` = 'propVirtual' OR `ports`.`ifType` = 'propPointToPointSerial' OR `ports`.`ifType` = 'other' OR `ports`.`ifType` = 'tunnel' OR `ports`.`ifType` = 'ieee8023adLag' OR `ports`.`ifType` = 'softwareLoopback' OR `ports`.`ifType` = 'fibreChannel' OR `ports`.`ifType` = 'ipForward' OR `ports`.`ifType` = 'l2vlan' OR `ports`.`ifType` = 'gigabitEthernet' OR `ports`.`ifType` = 'propMultiplexor') AND `ports`.`deleted` != '1'] SQL RUNTIME[0.01349998s]  SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '3'] SQL RUNTIME[0.02352500s] Alert Checker 'Traffic exceeds 80%': 5717 existing, 5717 new entries (+0/-0).  SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%')] SQL RUNTIME[0.00074410s]  SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '5'] SQL RUNTIME[0.00165486s] Alert Checker 'Device down': 161 existing, 161 new entries (+0/-0). SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( `sensors`.`sensor_class` = 'temperature') AND `sensors`.`sensor_deleted` != '1'] SQL RUNTIME[0.00634003s]  SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '6'] SQL RUNTIME[0.00507712s] Alert Checker 'Temperature is higher then 75 degrees': 567 existing, 567 new entries (+0/-0). ./discovery.php: 172.21.99.138 - 1 devices discovered in 5.494 secs SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1676283372'] SQL RUNTIME[0.00027299s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Discovered  1  o Discovery Time  5.494 secs  o Memory usage  40MB (peak: 40MB)  o MySQL Usage  Cell[23/0.029s] Row[68/0.071s] Rows[77/0.206s] Column[2/0.002s] Update[2/0.004s] Insert[1/0.002s] Delete[2/0.003s]  o RRDTool Usage