DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0086s]
CMD EXITDELAY[10ms]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: https://svn.observium.org/svn/observium/trunk
Relative URL: ^/observium/trunk
Repository Root: https://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 12458
Node Kind: directory
Schedule: normal
Last Changed Author: mike
Last Changed Rev: 12458
Last Changed Date: 2023-01-11 14:36:47 +0200 (Wed, 11 Jan 2023)

]
DEFINITIONS loaded by: 0.0735512 ms

DEFINITIONS in memory: 3.38MB


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00044394s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00016785s]

SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00013995s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ERROR_FOR_DIVISION_BY_ZERO

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00017500s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00022602s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00033712s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'cache_cli_clear';]
SQL RUNTIME[0.00022411s]

SQL[SELECT EXISTS (SELECT 1 FROM `pollers`)]
SQL RUNTIME[0.00022888s]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                          Observium Professional 23.1.12458
                                  https://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.0129s]
STDOUT[
Linux|5.15.0-57-generic|amd64|Ubuntu|22.04|kvm|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0027s]
STDOUT[
Python 3.10.6
]

SQL[SELECT version();]
SQL RUNTIME[0.00026011s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0029s]
STDOUT[
NET-SNMP version: 5.9.1
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.009s]
STDOUT[
RRDtool 1.7.2  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/rrdcached -h | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0084s]
STDOUT[
RRDCacheD 1.7.2
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0018s]
STDOUT[
/usr/bin/fping: Version 5.1
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0156s]
STDOUT[
Apache/2.4.52
]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00026679s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00072217s]

#####  Software versions  #####

 o OS                   Linux 5.15.0-57-generic [amd64] (Ubuntu 22.04)
 o Apache               2.4.52
 o PHP                  8.1.2-1ubuntu2.9 (OPcache: ENABLED)
 o Python               3.10.6
 o MariaDB              10.6.11-MariaDB-1:10.6.11+maria~ubu2204 (extension: mysqli 8.1.2-1ubuntu2.9)
 o SNMP                 NET-SNMP 5.9.1
 o RRDtool              1.7.2 (rrdcached 1.7.2: unix:/var/run/rrdcached.sock)
 o Fping                5.1 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  256MB

#####  DB info  #####

 o DB schema            477
 o MariaDB mode         NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MariaDB              utf8mb3

#####  Timezones info  #####

 o Date                 Thursday, 12-Jan-23 15:45:31 EET
 o PHP                  +02:00
 o MariaDB              +02:00

#####  Fast Cache info  #####

 o Enabled              Yes
 o Driver               Files
 o Total size           183B


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00033212s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00021815s]
#####  Starting discovery run at 2023-01-12 15:45:31  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'ups1.a1.nodefield.lan' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00058603s]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0257s]
STDOUT[
.1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.935.10.1
.1.3.6.1.2.1.1.3.0 = 32:11:03:01.70
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14']
SQL RUNTIME[0.00058293s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '14' AND `poller_id` = '0']
SQL RUNTIME[0.00029516s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('542124','discovery.php','499256','0','php ./discovery.php -d -h ups1.a1.nodefield.lan','1673531131','14')]
SQL RUNTIME[0.00769401s]
#####  ups1.a1.nodefield.lan [14]  #####

 o OS Type              eppc-ups
 o OS Group             ups
 o SNMP Version         v2c
 o Last discovery       2023-01-12 15:27:15
 o Last duration        6.29 seconds

#####  Module Start: os  #####


CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0225s]
STDOUT[
Network Management Card for UPS
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0219s]
STDOUT[
.1.3.6.1.4.1.935.10.1
]
SNMP STATUS[TRUE]
+-------------+---------------------------------+
| OID         |                                 |
+-------------+---------------------------------+
| sysDescr    | Network Management Card for UPS |
| sysObjectID | .1.3.6.1.4.1.935.10.1           |
+-------------+---------------------------------+

 o Detect OS matched (eppc-ups: EPPC UPS): 
+-------------+-----------------------+-----------------------+
| OID         | Matched definition    |                       |
+-------------+-----------------------+-----------------------+
| sysObjectID | .1.3.6.1.4.1.935.10.1 | .1.3.6.1.4.1.935.10.1 |
+-------------+-----------------------+-----------------------+


 o Duration             0.098s

#####  Module Start: mibs  #####


CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']

CMD EXITCODE[0]
CMD RUNTIME[0.0147s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2'

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' .1.3.6.1.2.1.1.9.1.2]

CMD EXITCODE[0]
CMD RUNTIME[0.0673s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1
.1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.10.3.1.1
.1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.6.3.11.3.1.1
.1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.6.3.15.2.1.1
.1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.6.3.16.2.1.1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' sysORDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0535s]
STDOUT[
sysORDescr.1 = The MIB Module from SNMPv2 entities
sysORDescr.2 = SNMP Management Architecture MIB
sysORDescr.3 = Message Processing and Dispatching MIB
sysORDescr.4 = USM User MIB
sysORDescr.5 = VACM MIB
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m OSPFV3-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ospfv3AdminStatus.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0278s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
Store in cache OID: OSPFV3-MIB::ospfv3AdminStatus.0
 o MIBs discovered      <empty>
SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00037909s]

+-----------------------+--------------------+---------+---------------------+
| Identity              | MIB                | Source  | Status              |
+-----------------------+--------------------+---------+---------------------+
| .1.3.6.1.6.3.1        | SNMPv2-MIB         | sysORID | MIB already defined |
| .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined |
| .1.3.6.1.6.3.11.3.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.15.2.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.16.2.1.1 | -                  | sysORID | Unknown Identity    |
+-----------------------+--------------------+---------+---------------------+


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00034094s]
JSON DECODE[Not string passed]
JSON RAW[


 > $str /opt/observium/includes/common.inc.php:5454 
null

]

SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '14' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00029087s]


  /opt/observium/includes/discovery/mibs.inc.php:313 
array(
  [0]  => string(8) "EPPC-MIB"
  [1]  => string(10) "SNMPv2-MIB"
  [2]  => string(18) "SNMP-FRAMEWORK-MIB"
  [3]  => string(6) "IF-MIB"
  [4]  => string(13) "ADSL-LINE-MIB"
  [5]  => string(13) "EtherLike-MIB"
  [6]  => string(10) "ENTITY-MIB"
  [7]  => string(17) "ENTITY-SENSOR-MIB"
  [8]  => string(12) "UCD-SNMP-MIB"
  [9]  => string(18) "HOST-RESOURCES-MIB"
  [10] => string(12) "Q-BRIDGE-MIB"
  [11] => string(6) "IP-MIB"
  [12] => string(8) "IPV6-MIB"
  [13] => string(8) "LLDP-MIB"
  [14] => string(13) "CISCO-CDP-MIB"
  [15] => string(15) "DISMAN-PING-MIB"
)

 o Duration             0.1772s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_vrf']
SQL RUNTIME[0.00028706s]
Module [vrf] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_ports']
SQL RUNTIME[0.00027585s]
#####  Module Start: ports  #####

 o Caching OIDs         ifDescr 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ifDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0677s]
STDOUT[
ifDescr.1 = lo
ifDescr.2 = eth0
]
SNMP STATUS[TRUE]
ifAlias 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ifAlias]

CMD EXITCODE[0]
CMD RUNTIME[0.0822s]
STDOUT[
ifAlias = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
ifName 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ifName]

CMD EXITCODE[0]
CMD RUNTIME[0.0917s]
STDOUT[
ifName = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
ifType 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ifType]

CMD EXITCODE[0]
CMD RUNTIME[0.0778s]
STDOUT[
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd
]
SNMP STATUS[TRUE]
ifOperStatus 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ifOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1593s]
STDOUT[
ifOperStatus.1 = up
ifOperStatus.2 = up
]
SNMP STATUS[TRUE]



  /opt/observium/includes/discovery/ports.inc.php:44 
array(
  [1] => array(
           [ifDescr]      => string(2) "lo"
           [ifType]       => string(16) "softwareLoopback"
           [ifOperStatus] => string(2) "up"
         )
  [2] => array(
           [ifDescr]      => string(4) "eth0"
           [ifType]       => string(14) "ethernetCsmacd"
           [ifOperStatus] => string(2) "up"
         )
)
 o Caching DB           
SQL[SELECT * FROM `ports` WHERE `device_id` = '14']
SQL RUNTIME[0.00055909s]
2 ports
 o Discovering ports    ..
+---------+---------+--------+---------+------------------+-------------+---------+
| ifIndex | ifDescr | ifName | ifAlias | ifType           | Oper Status | Ignored |
+---------+---------+--------+---------+------------------+-------------+---------+
| 1       | lo      |        | ...     | softwareLoopback | up          | no      |
| 2       | eth0    |        | ...     | ethernetCsmacd   | up          | no      |
+---------+---------+--------+---------+------------------+-------------+---------+


 o Duration             0.4902s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_ports-stack']
SQL RUNTIME[0.00033903s]
Module [ports-stack] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_vlans']
SQL RUNTIME[0.00029111s]
Module [vlans] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_oids']
SQL RUNTIME[0.00028992s]
#####  Module Start: oids  #####


SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '14']
SQL RUNTIME[0.00034499s]

SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1']
SQL RUNTIME[0.00023794s]

 o Duration             0.0017s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_ip-addresses']
SQL RUNTIME[0.00023794s]
#####  Module Start: ip-addresses  #####


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00028777s]
JSON DECODE[Not string passed]
JSON RAW[


  /opt/observium/includes/common.inc.php:5454 
null

]
 o IP-MIB               
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipAdEntIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0774s]
STDOUT[
ipAdEntIfIndex.10.16.2.1 = 2
ipAdEntIfIndex.127.0.0.1 = 1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipAdEntNetMask]

CMD EXITCODE[0]
CMD RUNTIME[0.0736s]
STDOUT[
ipAdEntNetMask.10.16.2.1 = 255.255.0.0
ipAdEntNetMask.127.0.0.1 = 255.255.255.255
]
SNMP STATUS[TRUE]
Added 10.16.2.1
.Added 127.0.0.1
.
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipAddressIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0872s]
STDOUT[
ipAddressIfIndex = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o IPV6-MIB             
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipv6AddrEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0849s]
STDOUT[
ipv6AddrEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o LLDP-MIB             

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '14']
SQL RUNTIME[0.00026989s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '14' AND `ifIndex` = '2' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00033402s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '164']
SQL RUNTIME[0.00030804s]

SQL[SELECT DISTINCT `entity_type` FROM `entity_attribs` WHERE `device_id` = '14']
SQL RUNTIME[0.00029302s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '164']
SQL RUNTIME[0.00026584s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '14']
SQL RUNTIME[0.00035310s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '14']
SQL RUNTIME[0.00034690s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.16.0.0/16']
SQL RUNTIME[0.00025296s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '14' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00023413s]

SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '163']
SQL RUNTIME[0.00035501s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '163']
SQL RUNTIME[0.00029397s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32']
SQL RUNTIME[0.00027514s]

SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '14']
SQL RUNTIME[0.00025511s]

SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '14']
SQL RUNTIME[0.00023985s]
+---------+---------+-------------+--------------+--------------+----------+--------+
| ifIndex | ifDescr | IP: Version | Address      | Network      | Type     | Origin |
+---------+---------+-------------+--------------+--------------+----------+--------+
| 2       | eth0    | IPv4        | 10.16.2.1/16 | 10.16.0.0/16 | private  |        |
| 1       | lo      | IPv4        | 127.0.0.1/32 | 127.0.0.1/32 | loopback |        |
+---------+---------+-------------+--------------+--------------+----------+--------+


 o Changes              2 unchanged
 o Duration             0.3483s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_processors']
SQL RUNTIME[0.00028110s]
#####  Module Start: processors  #####

 o UCD-SNMP-MIB         
SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '14' AND `processor_type` != 'ucd-old')]
SQL RUNTIME[0.00025392s]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ssCpuIdle.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0231s]
CMD EXITDELAY[10ms]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' hrProcessorLoad]

CMD EXITCODE[0]
CMD RUNTIME[0.0844s]
STDOUT[
hrProcessorLoad = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `processors` WHERE `device_id` = '14']
SQL RUNTIME[0.00068808s]

 o Duration             0.1232s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_mempools']
SQL RUNTIME[0.00027585s]
#####  Module Start: mempools  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0449s]
STDOUT[
memTotalReal.0 = No Such Object available on this agent at this OID
memAvailReal.0 = No Such Object available on this agent at this OID
memBuffer.0 = No Such Object available on this agent at this OID
memCached.0 = No Such Object available on this agent at this OID
]
SNMP ERROR[#1000 - Failed response]
SNMP STATUS[FALSE]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0833s]
STDOUT[
hrStorageEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `mempools` WHERE `device_id` = '14']
SQL RUNTIME[0.00045109s]

 o Duration             0.1334s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_inventory']
SQL RUNTIME[0.00030804s]
#####  Module Start: inventory  #####

 o ENTITY-MIB           ENTITY-MIB 
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'ups1.a1.nodefield.lan':'161' entPhysicalEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1731s]
STDOUT[
entPhysicalEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' hrDeviceEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0846s]
STDOUT[
hrDeviceEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' hrProcessorEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0941s]
STDOUT[
hrProcessorEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '14']
SQL RUNTIME[0.00043511s]


SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '14']
SQL RUNTIME[0.00022602s]

 o Duration             0.3609s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_printersupplies']
SQL RUNTIME[0.00033998s]
#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '14']
SQL RUNTIME[0.00028396s]


 o Duration             0.0011s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_sensors']
SQL RUNTIME[0.00046396s]
#####  Module Start: sensors  #####

 o EPPC-MIB             upsESystemTemperature [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.1508s]
STDOUT[
upsESystemTemperature.0 = 213
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemTemperature

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemConfigOverTemperatureSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.1358s]
STDOUT[
upsESystemConfigOverTemperatureSetPoint.0 = 500
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemConfigOverTemperatureSetPoint
Discover sensor: [class: temperature, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.2.0, index: 0, type: EPPC-MIB-upsESystemTemperature, descr: System, scale: 0.1, limits: (, , , 50), CURRENT: 21.3, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0')]
SQL RUNTIME[0.00058389s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemTemperature' AND `sensor_index` = '0']
SQL RUNTIME[0.00039601s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1916' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00033092s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1916' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00022292s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-temperature-eppc-mib-upsESystemTemperature.rrd'
] upsEEnvironmentCurrentTemperature [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentCurrentTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.088s]
STDOUT[
upsEEnvironmentCurrentTemperature.0 = -1
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentTemperature

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentTemperatureLowSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.09s]
STDOUT[
upsEEnvironmentTemperatureLowSetPoint.0 = 150
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureLowSetPoint

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentTemperatureHighSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.095s]
STDOUT[
upsEEnvironmentTemperatureHighSetPoint.0 = 500
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentTemperatureHighSetPoint
Excluded by current value (-1) in invalid range [-1].
] upsEEnvironmentCurrentHumidity [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentCurrentHumidity]

CMD EXITCODE[0]
CMD RUNTIME[0.1302s]
STDOUT[
upsEEnvironmentCurrentHumidity.0 = -1
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentCurrentHumidity

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentHumidityLowSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.1294s]
STDOUT[
upsEEnvironmentHumidityLowSetPoint.0 = 50
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityLowSetPoint

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEEnvironmentHumidityHighSetPoint]

CMD EXITCODE[0]
CMD RUNTIME[0.1866s]
STDOUT[
upsEEnvironmentHumidityHighSetPoint.0 = 90
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEEnvironmentHumidityHighSetPoint
Excluded by current value (-1) in invalid range [-1].
] upsEPositiveBatteryVoltage [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEPositiveBatteryVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.2003s]
STDOUT[
upsEPositiveBatteryVoltage.0 = 3277
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEPositiveBatteryVoltage
Discover sensor: [class: voltage, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.3.5.0, index: 0, type: EPPC-MIB-upsEPositiveBatteryVoltage, descr: Battery, scale: 0.1, limits: (, , , ), CURRENT: 327.7, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0')]
SQL RUNTIME[0.00079608s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEPositiveBatteryVoltage' AND `sensor_index` = '0']
SQL RUNTIME[0.00076604s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1917' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00050092s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1917' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00045490s]
.] upsEBatteryEstimatedChargeRemaining [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEBatteryEstimatedChargeRemaining]

CMD EXITCODE[0]
CMD RUNTIME[0.1679s]
STDOUT[
upsEBatteryEstimatedChargeRemaining.0 = 100
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedChargeRemaining
Discover sensor: [class: capacity, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.3.4.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedChargeRemaining, descr: Battery Charge Remaining, scale: 1, limits: (10, 20, , ), CURRENT: 100, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0')]
SQL RUNTIME[0.00094604s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedChargeRemaining' AND `sensor_index` = '0']
SQL RUNTIME[0.00082493s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1918' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00059295s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1918' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00061703s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-capacity-eppc-mib-upsEBatteryEstimatedChargeRemaining.rrd'
] upsEBatteryEstimatedMinutesRemaining [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEBatteryEstimatedMinutesRemaining]

CMD EXITCODE[0]
CMD RUNTIME[0.1149s]
STDOUT[
upsEBatteryEstimatedMinutesRemaining.0 = 29
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryEstimatedMinutesRemaining
Discover sensor: [class: runtime, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.3.3.0, index: 0, type: EPPC-MIB-upsEBatteryEstimatedMinutesRemaining, descr: Battery Runtime Remaining, scale: 1, limits: (5, 20, , ), CURRENT: 29, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0')]
SQL RUNTIME[0.00081801s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsEBatteryEstimatedMinutesRemaining' AND `sensor_index` = '0']
SQL RUNTIME[0.00075197s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1919' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00052190s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1919' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00058913s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-runtime-eppc-mib-upsEBatteryEstimatedMinutesRemaining.0.rrd'
] upsESecondsOnBattery [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESecondsOnBattery]

CMD EXITCODE[0]
CMD RUNTIME[0.0995s]
STDOUT[
upsESecondsOnBattery.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESecondsOnBattery
Discover sensor: [class: runtime, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.3.2.0, index: 0, type: EPPC-MIB-upsESecondsOnBattery, descr: Battery Runtime, scale: 0.016666666666667, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0')]
SQL RUNTIME[0.00080705s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESecondsOnBattery' AND `sensor_index` = '0']
SQL RUNTIME[0.00085282s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1920' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00062203s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1920' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00051188s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-runtime-eppc-mib-upsESecondsOnBattery.0.rrd'
] 
 o EPPC-MIB             upsESystemStatus [
CMD[/usr/bin/snmptranslate -On -Pu -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'EPPC-MIB::upsESystemStatus']

CMD EXITCODE[0]
CMD RUNTIME[0.0365s]
STDOUT[
.1.3.6.1.4.1.935.10.1.1.2.1
]
SNMP TRANSLATE (CMD): 'EPPC-MIB::upsESystemStatus' -> '.1.3.6.1.4.1.935.10.1.1.2.1'

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1335s]
STDOUT[
upsESystemStatus.0 = line
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsESystemStatus
Discover status: [device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.1.0, index: 0, type: upsESystemStatus, descr: System Status, CURRENT: 4, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '14' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00093508s]

SQL[SELECT * FROM `status` WHERE `device_id` = '14' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsESystemStatus' AND `status_type` = 'upsESystemStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00077796s]
.] upsEBatteryStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUsb -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsEBatteryStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1651s]
STDOUT[
upsEBatteryStatus.0 = batteryNormal
]
SNMP STATUS[TRUE]
Store in cache Table OID: EPPC-MIB::upsEBatteryStatus
Discover status: [device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.3.1.0, index: 0, type: upsEBatteryStatus, descr: Battery Status, CURRENT: 2, , battery]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '14' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00085807s]

SQL[SELECT * FROM `status` WHERE `device_id` = '14' AND `status_mib` = 'EPPC-MIB' AND `status_object` = 'upsEBatteryStatus' AND `status_type` = 'upsEBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00079894s]
.] 
 o EPPC-MIB             
CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemInputNumPhases.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0402s]
STDOUT[
3
]
SNMP STATUS[TRUE]
upsESystemInputTable (3 phases)
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemInputTable]

CMD EXITCODE[0]
CMD RUNTIME[0.1486s]
STDOUT[
upsESystemInputFrequency.1 = 499
upsESystemInputFrequency.2 = -1
upsESystemInputFrequency.3 = -1
upsESystemInputVoltage.1 = 2293
upsESystemInputVoltage.2 = 2309
upsESystemInputVoltage.3 = 2322
upsESystemInputCurrent.1 = -1
upsESystemInputCurrent.2 = -1
upsESystemInputCurrent.3 = -1
upsESystemInputWatts.1 = -1
upsESystemInputWatts.2 = -1
upsESystemInputWatts.3 = -1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemConfigInputVoltage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0388s]
STDOUT[
2300
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemConfigInputFrequence.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0392s]
STDOUT[
500
]
SNMP STATUS[TRUE]
Discover sensor: [class: voltage, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.3.1, index: 1, type: EPPC-MIB-upsESystemInputVoltage, descr: Input (Phase 1), scale: 0.1, limits: (223.1, 227.7, 232.3, 236.9), CURRENT: 229.3, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1')]
SQL RUNTIME[0.00082898s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '1']
SQL RUNTIME[0.00092411s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1921' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00053501s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1921' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00060606s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-voltage-eppc-mib-upsESystemInputVoltage.1.rrd'
Discover sensor: [class: frequency, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.2.1, index: 1, type: EPPC-MIB-upsESystemInputFrequency, descr: Input (Phase 1), scale: 0.1, limits: (45, 49, 51, 55), CURRENT: 49.9, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1')]
SQL RUNTIME[0.00078177s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '1']
SQL RUNTIME[0.00070500s]
LCurrent sensor value: "49.9", scale: "0.1"
  limit_high: "55" -> "55"
  limit_high_warn: "51" -> "51"
  limit_low: "45" -> "45"
  limit_low_warn: "49" -> "49"


SQL[UPDATE `sensors` set `sensor_limit` ='55' WHERE `sensor_id` = '1922']
SQL RUNTIME[0.00058103s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1922' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00062704s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1922' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00055909s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-frequency-eppc-mib-upsESystemInputFrequency.1.rrd'
Discover sensor: [class: voltage, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.3.2, index: 2, type: EPPC-MIB-upsESystemInputVoltage, descr: Input (Phase 2), scale: 0.1, limits: (223.1, 227.7, 232.3, 236.9), CURRENT: 230.9, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '2')]
SQL RUNTIME[0.00076699s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '2']
SQL RUNTIME[0.00082493s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1923' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00062180s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1923' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00056386s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-voltage-eppc-mib-upsESystemInputVoltage.2.rrd'
Discover sensor: [class: frequency, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.2.2, index: 2, type: EPPC-MIB-upsESystemInputFrequency, descr: Input (Phase 2), scale: 0.1, limits: (45, 49, 51, 55), CURRENT: -0.1, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '2')]
SQL RUNTIME[0.00070000s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '2']
SQL RUNTIME[0.00075698s]
LCurrent sensor value: "-0.1", scale: "0.1"
  limit_high: "55" -> "55"
  limit_high_warn: "51" -> "51"
  limit_low: "45" -> "45"
  limit_low_warn: "49" -> "49"


SQL[UPDATE `sensors` set `sensor_limit` ='55' WHERE `sensor_id` = '1924']
SQL RUNTIME[0.00052810s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1924' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00055981s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1924' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00056481s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-frequency-eppc-mib-upsESystemInputFrequency.2.rrd'
Discover sensor: [class: voltage, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.3.3, index: 3, type: EPPC-MIB-upsESystemInputVoltage, descr: Input (Phase 3), scale: 0.1, limits: (223.1, 227.7, 232.3, 236.9), CURRENT: 232.2, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '3')]
SQL RUNTIME[0.00064206s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputVoltage' AND `sensor_index` = '3']
SQL RUNTIME[0.00073099s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1925' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00053811s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1925' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00066781s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-voltage-eppc-mib-upsESystemInputVoltage.3.rrd'
Discover sensor: [class: frequency, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.16.1.2.3, index: 3, type: EPPC-MIB-upsESystemInputFrequency, descr: Input (Phase 3), scale: 0.1, limits: (45, 49, 51, 55), CURRENT: -0.1, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '3')]
SQL RUNTIME[0.00069284s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemInputFrequency' AND `sensor_index` = '3']
SQL RUNTIME[0.00082898s]
LCurrent sensor value: "-0.1", scale: "0.1"
  limit_high: "55" -> "55"
  limit_high_warn: "51" -> "51"
  limit_low: "45" -> "45"
  limit_low_warn: "49" -> "49"


SQL[UPDATE `sensors` set `sensor_limit` ='55' WHERE `sensor_id` = '1926']
SQL RUNTIME[0.00054216s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1926' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00065708s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1926' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00061202s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-frequency-eppc-mib-upsESystemInputFrequency.3.rrd'

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemOutputNumPhase.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0421s]
STDOUT[
1
]
SNMP STATUS[TRUE]
upsESystemOutputTable (1 phases)
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemOutputTable]

CMD EXITCODE[0]
CMD RUNTIME[0.0955s]
STDOUT[
upsESystemOutputFrequency.1 = 499
upsESystemOutputVoltage.1 = 2302
upsESystemOutputCurrent.1 = 105
upsESystemOutputWatts.1 = 2100
upsESystemOutputVA.1 = 2400
upsESystemOutputLoad.1 = 24
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemConfigOutputVoltage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0405s]
STDOUT[
-1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemConfigOutputFrequency.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0392s]
STDOUT[
-1
]
SNMP STATUS[TRUE]
Discover sensor: [class: voltage, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.3., index: 1, type: EPPC-MIB-upsESystemOutputVoltage, descr: Output (Phase 1), scale: 0.1, limits: (223.1, 227.7, 232.3, 236.9), CURRENT: 230.2, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1')]
SQL RUNTIME[0.00095415s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVoltage' AND `sensor_index` = '1']
SQL RUNTIME[0.00081205s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1927' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00065613s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1927' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00059009s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-voltage-eppc-mib-upsESystemOutputVoltage.1.rrd'
Discover sensor: [class: frequency, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.2., index: 1, type: EPPC-MIB-upsESystemOutputFrequency, descr: Output (Phase 1), scale: 0.1, limits: (45, 49, 51, 55), CURRENT: 49.9, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1')]
SQL RUNTIME[0.00075316s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputFrequency' AND `sensor_index` = '1']
SQL RUNTIME[0.00079489s]
LCurrent sensor value: "49.9", scale: "0.1"
  limit_high: "55" -> "55"
  limit_high_warn: "51" -> "51"
  limit_low: "45" -> "45"
  limit_low_warn: "49" -> "49"


SQL[UPDATE `sensors` set `sensor_limit` ='55' WHERE `sensor_id` = '1928']
SQL RUNTIME[0.00058103s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1928' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00061798s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1928' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00063992s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-frequency-eppc-mib-upsESystemOutputFrequency.1.rrd'
Discover sensor: [class: load, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.7., index: 1, type: EPPC-MIB-upsESystemOutputLoad, descr: Output (Phase 1), scale: 1, limits: (, , 75, 90), CURRENT: 24, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1')]
SQL RUNTIME[0.00070500s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputLoad' AND `sensor_index` = '1']
SQL RUNTIME[0.00082207s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1929' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00061798s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1929' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00061798s]
.RRD old file not found: '/opt/observium/rrd/ups1.a1.nodefield.lan/sensor-load-eppc-mib-upsESystemOutputLoad.1.rrd'
Discover sensor: [class: current, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.4.1, index: 1, type: EPPC-MIB-upsESystemOutputCurrent, descr: Output (Phase 1), scale: 0.1, limits: (, , , ), CURRENT: 10.5, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputCurrent' AND `sensor_index` = '1')]
SQL RUNTIME[0.00077295s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputCurrent' AND `sensor_index` = '1']
SQL RUNTIME[0.00078893s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1930' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00064397s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1930' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00061703s]
.Discover sensor: [class: power, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.5.1, index: 1, type: EPPC-MIB-upsESystemOutputWatts, descr: Output (Phase 1), scale: 1, limits: (, , , ), CURRENT: 2100, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputWatts' AND `sensor_index` = '1')]
SQL RUNTIME[0.00080895s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputWatts' AND `sensor_index` = '1']
SQL RUNTIME[0.00071907s]
LCurrent sensor value: "2100", scale: "1"
  limit_high: "3300" -> "3150"
  limit_high_warn: "" -> ""
  limit_low: "" -> ""
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='3150' WHERE `sensor_id` = '1931']
SQL RUNTIME[0.00747013s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1931' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00063300s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1931' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00063086s]
.Discover sensor: [class: apower, device: ups1.a1.nodefield.lan, oid: .1.3.6.1.4.1.935.10.1.1.2.18.1.6.1, index: 1, type: EPPC-MIB-upsESystemOutputVA, descr: Output (Phase 1), scale: 1, limits: (, , , ), CURRENT: 2400, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'apower' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVA' AND `sensor_index` = '1')]
SQL RUNTIME[0.00079298s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'apower' AND `device_id` = '14' AND `sensor_type` = 'EPPC-MIB-upsESystemOutputVA' AND `sensor_index` = '1']
SQL RUNTIME[0.00083208s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1932' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00060415s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1932' AND `attrib_type` = 'oid_scale_si']
SQL RUNTIME[0.00063086s]
.
CMD[/usr/bin/snmpget -t '10' -r '7' -v2c -c *** -Pud -OQUv -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemBypassNumPhase.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0399s]
STDOUT[
3
]
SNMP STATUS[TRUE]
upsESystemBypassTable (3 phases)
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m EPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/powerwalker 'udp':'ups1.a1.nodefield.lan':'161' upsESystemBypassTable]

CMD EXITCODE[0]
CMD RUNTIME[0.2799s]
STDOUT[
upsESystemBypassFrequency.1 = 0
upsESystemBypassFrequency.2 = -1
upsESystemBypassFrequency.3 = -1
upsESystemBypassVoltage.1 = 0
upsESystemBypassVoltage.2 = 0
upsESystemBypassVoltage.3 = 0
upsESystemBypassCurrent.1 = -1
upsESystemBypassCurrent.2 = -1
upsESystemBypassCurrent.3 = -1
upsESystemBypassWatts.1 = -1
upsESystemBypassWatts.2 = -1
upsESystemBypassWatts.3 = -1
]
SNMP STATUS[TRUE]

 o ENTITY-SENSOR-MIB    
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.1012s]
STDOUT[
entPhySensorValue = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00167108s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00073409s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00089002s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00073099s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00082207s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00109601s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00093794s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00091290s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00092006s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00073791s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00066996s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00078392s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00066400s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00073504s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00101900s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00090909s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00066495s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00066590s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00077796s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00072408s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00074506s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00093293s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00091887s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00084496s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00074697s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00072503s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00075388s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00072789s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00071311s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00072718s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00080991s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '14' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00065708s]

SQL[SELECT * FROM `status` WHERE `device_id` = '14' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00073504s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '14' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00063300s]


 o Duration             3.1228s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_storage']
SQL RUNTIME[0.00060821s]
#####  Module Start: storage  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' dskEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0783s]
STDOUT[
dskEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.099s]
STDOUT[
hrStorageEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `storage` WHERE `device_id` = '14']
SQL RUNTIME[0.00068808s]

 o Duration             0.185s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_neighbours']
SQL RUNTIME[0.00066900s]
#####  Module Start: neighbours  #####

 o LLDP-MIB             
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' lldpRemChassisIdSubtype]

CMD EXITCODE[0]
CMD RUNTIME[0.11s]
STDOUT[
lldpRemChassisIdSubtype = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o CISCO-CDP-MIB        
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'ups1.a1.nodefield.lan':'161' cdpCache]

CMD EXITCODE[0]
CMD RUNTIME[0.1883s]
STDOUT[
cdpCache = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `neighbours` WHERE `device_id` = '14']
SQL RUNTIME[0.00070095s]



 o Duration             0.3061s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_arp-table']
SQL RUNTIME[0.00065088s]
#####  Module Start: arp-table  #####


SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '14' GROUP BY `port_id`]
SQL RUNTIME[0.00072598s]

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipNetToPhysicalPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0931s]
STDOUT[
ipNetToPhysicalPhysAddress[1] Wrong Type (should be OCTET STRING): 0
ipNetToPhysicalPhysAddress[2] Wrong Type (should be OCTET STRING): 0
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToPhysicalPhysAddress

CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' ipNetToMediaPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.1059s]
STDOUT[
ipNetToMediaPhysAddress[2][10.16.0.254] 2e:49:5:f3:12:89
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToMediaPhysAddress

SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M LEFT JOIN ports AS I ON M.port_id = I.port_id WHERE I.device_id = '14']
SQL RUNTIME[0.00083804s]
.

 o Duration             0.2098s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_junose-atm-vp']
SQL RUNTIME[0.00060701s]
Module [junose-atm-vp] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_bgp-peers']
SQL RUNTIME[0.00061703s]
Module [bgp-peers] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_mac-accounting']
SQL RUNTIME[0.00056481s]
#####  Module Start: mac-accounting  #####


 o Duration             0.0003s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_sla']
SQL RUNTIME[0.00067091s]
#####  Module Start: sla  #####

 o DISMAN-PING-MIB      
CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' pingCtlEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1323s]
STDOUT[
pingCtlEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `slas` WHERE `device_id` = '14']
SQL RUNTIME[0.00070405s]

 o Duration             0.1374s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_lsp']
SQL RUNTIME[0.00067616s]
Module [lsp] disabled globally by config in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_pseudowires']
SQL RUNTIME[0.00062895s]
Module [pseudowires] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_virtual-machines']
SQL RUNTIME[0.00064015s]
#####  Module Start: virtual-machines  #####



 o Duration             0.0007s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_cisco-cbqos']
SQL RUNTIME[0.00060010s]
Module [cisco-cbqos] blacklisted by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_ucd-diskio']
SQL RUNTIME[0.00071096s]
#####  Module Start: ucd-diskio  #####


CMD[/usr/bin/snmpbulkwalk -t '10' -r '7' -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups1.a1.nodefield.lan':'161' diskIOEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1349s]
STDOUT[
diskIOEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '14']
SQL RUNTIME[0.00068712s]


 o Duration             0.1401s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_wifi']
SQL RUNTIME[0.00061703s]
Module [wifi] disabled for device type 'power'. in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_p2p-radios']
SQL RUNTIME[0.00060987s]
Module [p2p-radios] disabled by os definition in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_graphs']
SQL RUNTIME[0.00061107s]
#####  Module Start: graphs  #####


 o Duration             0.0006s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '14' AND `attrib_type` = 'discover_raid']
SQL RUNTIME[0.00064778s]
Module [raid] disabled by os definition in process [discovery].
 o Modules Excluded     vrf, junose-atm-vp, cisco-cbqos
 o Modules Disabled     ports-stack, vlans, bgp-peers, lsp, pseudowires, wifi, p2p-radios, raid
 o Modules Enabled      os, mibs, ports, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage, neighbours, 
                        arp-table,mac-accounting, sla, virtual-machines, ucd-diskio, graphs 

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '14';]
SQL RUNTIME[0.00057316s]

SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='5.8914',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:23:{s:6:\"system\";d:0.2933;s:2:\"os\";d:0.1517;s:7:\"sensors\";d:0.6343;s:6:\"status\";d:0.0385;s:7:\"counter\";d:0.0007;s:10:\"processors\";d:0.0009;s:8:\"mempools\";d:0.001;s:7:\"storage\";d:0.0076;s:7:\"ucd-mib\";d:0.074;s:13:\"ipSystemStats\";d:0.503;s:5:\"ports\";d:1.199;s:15:\"printersupplies\";d:0.0007;s:10:\"ucd-diskio\";d:0.0005;s:4:\"ospf\";d:0.0002;s:3:\"sla\";d:0.0009;s:14:\"mac-accounting\";d:0.001;s:12:\"loadbalancer\";d:0.0002;s:15:\"entity-physical\";d:0.0005;s:12:\"applications\";d:0.0006;s:9:\"fdb-table\";d:0.181;s:6:\"graphs\";d:0.0735;s:4:\"oids\";d:0.0011;s:6:\"probes\";d:0.0012;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.5459001064300537;s:13:\"EtherLike-MIB\";d:0.08464193344116211;s:12:\"Q-BRIDGE-MIB\";d:0.36346006393432617;s:6:\"IP-MIB\";d:0.17070698738098145;}s:14:\"poller_history\";a:288:{i:1673530902;d:3.2755;i:1673530604;d:3.4947;i:1673530297;d:3.7368;i:1673530051;d:3.6622;i:1673530002;d:3.1594;i:1673529701;d:3.3957;i:1673529395;d:3.3286;i:1673529103;d:3.5311;i:1673528804;d:3.479;i:1673528496;d:3.2515;i:1673528199;d:3.5782;i:1673527905;d:3.7461;i:1673527605;d:3.1734;i:1673527302;d:3.4345;i:1673527001;d:3.4508;i:1673526702;d:3.6466;i:1673526398;d:3.3436;i:1673526103;d:3.4833;i:1673525802;d:3.3996;i:1673525506;d:3.6197;i:1673525201;d:3.2983;i:1673524900;d:3.5615;i:1673524602;d:3.423;i:1673524302;d:3.4873;i:1673523996;d:3.4483;i:1673523692;d:3.6389;i:1673523404;d:3.9077;i:1673523095;d:3.443;i:1673522791;d:3.821;i:1673522508;d:3.6268;i:1673522187;d:3.0969;i:1673521909;d:4.0142;i:1673521625;d:3.3854;i:1673521308;d:3.2409;i:1673520994;d:3.4956;i:1673520701;d:3.6726;i:1673520394;d:3.4297;i:1673520101;d:3.8467;i:1673519805;d:3.4168;i:1673519501;d:3.5146;i:1673519201;d:3.4482;i:1673518903;d:3.3716;i:1673518599;d:3.6541;i:1673518304;d:3.3801;i:1673518004;d:3.24;i:1673517703;d:3.597;i:1673517397;d:3.4261;i:1673517100;d:3.4982;i:1673516804;d:3.4684;i:1673516503;d:3.2914;i:1673516202;d:3.4269;i:1673515908;d:3.3472;i:1673515600;d:3.0451;i:1673515302;d:3.645;i:1673514991;d:3.5094;i:1673514703;d:3.7005;i:1673514400;d:3.1164;i:1673514090;d:3.6806;i:1673513802;d:4.2912;i:1673513498;d:3.4071;i:1673513203;d:3.4566;i:1673512902;d:3.3452;i:1673512599;d:3.3086;i:1673512307;d:3.427;i:1673512007;d:3.0572;i:1673511698;d:3.4058;i:1673511397;d:3.4818;i:1673511102;d:3.4884;i:1673510802;d:3.4386;i:1673510502;d:3.6;i:1673510206;d:3.6247;i:1673509901;d:3.5084;i:1673509608;d:3.4396;i:1673509313;d:3.2785;i:1673508987;d:3.146;i:1673508698;d:4.6262;i:1673508398;d:3.7715;i:1673508097;d:3.5263;i:1673507804;d:3.4184;i:1673507499;d:3.0532;i:1673507203;d:3.4073;i:1673506902;d:3.427;i:1673506600;d:3.2487;i:1673506296;d:3.377;i:1673506003;d:3.2152;i:1673505694;d:3.4257;i:1673505400;d:4.1441;i:1673505100;d:3.5549;i:1673504799;d:3.6112;i:1673504501;d:3.4613;i:1673504209;d:3.2818;i:1673503899;d:3.3332;i:1673503609;d:3.5306;i:1673503295;d:3.2132;i:1673503003;d:3.5672;i:1673502699;d:3.3496;i:1673502404;d:3.6501;i:1673502107;d:3.5205;i:1673501803;d:3.2659;i:1673501498;d:3.4659;i:1673501204;d:3.4441;i:1673500896;d:3.4141;i:1673500606;d:3.6213;i:1673500295;d:3.189;i:1673499999;d:3.4786;i:1673499697;d:3.5923;i:1673499385;d:3.7255;i:1673499094;d:4.1976;i:1673498802;d:3.6072;i:1673498498;d:3.3988;i:1673498210;d:3.4991;i:1673497888;d:3.3591;i:1673497596;d:3.8486;i:1673497308;d:3.427;i:1673497002;d:3.3071;i:1673496692;d:3.3533;i:1673496401;d:3.9352;i:1673496109;d:3.5038;i:1673495801;d:3.0263;i:1673495502;d:3.489;i:1673495198;d:3.1329;i:1673494895;d:3.4309;i:1673494604;d:3.6019;i:1673494295;d:3.6122;i:1673494003;d:4.3406;i:1673493701;d:3.4077;i:1673493404;d:3.4067;i:1673493104;d:3.2231;i:1673492798;d:3.4211;i:1673492494;d:3.6342;i:1673492204;d:3.3931;i:1673491898;d:3.2291;i:1673491609;d:3.7623;i:1673491299;d:3.4543;i:1673491000;d:3.65;i:1673490697;d:3.478;i:1673490402;d:3.6216;i:1673490102;d:3.6247;i:1673489801;d:3.4204;i:1673489509;d:3.4296;i:1673489208;d:3.2736;i:1673488896;d:3.551;i:1673488597;d:3.705;i:1673488302;d:3.9339;i:1673487995;d:3.7576;i:1673487699;d:3.748;i:1673487397;d:3.2884;i:1673487098;d:3.407;i:1673486807;d:3.3064;i:1673486499;d:3.5284;i:1673486203;d:3.3432;i:1673485904;d:3.3942;i:1673485604;d:3.1529;i:1673485302;d:3.5455;i:1673485000;d:3.5233;i:1673484697;d:3.5707;i:1673484402;d:3.3813;i:1673484102;d:3.2086;i:1673483801;d:3.471;i:1673483504;d:3.5832;i:1673483205;d:3.6243;i:1673482907;d:3.5218;i:1673482602;d:3.4588;i:1673482300;d:3.2717;i:1673482012;d:3.6681;i:1673481704;d:3.4072;i:1673481401;d:3.4646;i:1673481097;d:3.7139;i:1673480800;d:3.3743;i:1673480514;d:3.2788;i:1673480213;d:3.1797;i:1673479901;d:3.1861;i:1673479600;d:3.6455;i:1673479302;d:3.3623;i:1673479005;d:3.3922;i:1673478695;d:3.6821;i:1673478400;d:3.5721;i:1673478097;d:3.7012;i:1673477803;d:3.5631;i:1673477495;d:3.4855;i:1673477192;d:3.5554;i:1673476890;d:4.0801;i:1673476602;d:4.2795;i:1673476307;d:3.8849;i:1673475999;d:3.339;i:1673475693;d:3.4751;i:1673475394;d:4.1455;i:1673475102;d:3.685;i:1673474806;d:3.4538;i:1673474512;d:3.471;i:1673474218;d:3.5096;i:1673473912;d:3.0892;i:1673473602;d:3.6545;i:1673473305;d:3.3842;i:1673473020;d:3.2409;i:1673472704;d:3.1765;i:1673472402;d:3.1222;i:1673472099;d:3.6361;i:1673471806;d:3.3611;i:1673471505;d:3.2126;i:1673471194;d:3.7928;i:1673470892;d:3.5277;i:1673470606;d:3.7971;i:1673470302;d:3.3784;i:1673470004;d:3.357;i:1673469701;d:3.4402;i:1673469383;d:3.4148;i:1673469103;d:4.5234;i:1673468797;d:3.4551;i:1673468500;d:3.5389;i:1673468202;d:3.2872;i:1673467901;d:3.5758;i:1673467607;d:3.5116;i:1673467301;d:3.3997;i:1673466992;d:3.4669;i:1673466695;d:4.1659;i:1673466399;d:3.7907;i:1673466101;d:3.3463;i:1673465799;d:3.4452;i:1673465502;d:3.8286;i:1673465199;d:3.3996;i:1673464896;d:3.5152;i:1673464596;d:3.4552;i:1673464303;d:3.4172;i:1673464003;d:3.5063;i:1673463698;d:3.4885;i:1673463399;d:3.618;i:1673463102;d:3.7014;i:1673462791;d:3.3547;i:1673462499;d:3.9208;i:1673462194;d:3.4243;i:1673461899;d:3.6022;i:1673461590;d:3.4001;i:1673461287;d:3.8145;i:1673461000;d:4.1381;i:1673460697;d:3.318;i:1673460401;d:3.4236;i:1673460108;d:3.4307;i:1673459799;d:3.2636;i:1673459497;d:3.4407;i:1673459197;d:3.6096;i:1673458903;d:3.6275;i:1673458607;d:3.3933;i:1673458304;d:3.3567;i:1673458000;d:3.5147;i:1673457701;d:3.2843;i:1673457393;d:3.2707;i:1673457102;d:4.5227;i:1673456796;d:3.5208;i:1673456501;d:3.9001;i:1673456201;d:3.3225;i:1673455901;d:3.1924;i:1673455602;d:3.4843;i:1673455306;d:3.3384;i:1673455009;d:3.259;i:1673454705;d:3.2868;i:1673454403;d:3.1871;i:1673454101;d:3.3634;i:1673453800;d:3.4608;i:1673453497;d:3.7344;i:1673453202;d:3.5658;i:1673452902;d:3.4861;i:1673452597;d:3.5114;i:1673452302;d:3.6402;i:1673451997;d:3.2196;i:1673451701;d:3.4669;i:1673451393;d:3.3662;i:1673451102;d:4.0648;i:1673450797;d:3.331;i:1673450500;d:3.3174;i:1673450203;d:3.3918;i:1673449901;d:3.5062;i:1673449599;d:3.2789;i:1673449306;d:3.4734;i:1673449000;d:3.1195;i:1673448696;d:3.5107;i:1673448397;d:3.7158;i:1673448103;d:3.491;i:1673447815;d:3.3995;i:1673447503;d:3.2321;i:1673447202;d:3.2816;i:1673446903;d:3.6161;i:1673446605;d:3.4041;i:1673446310;d:3.0875;i:1673445998;d:3.2981;i:1673445693;d:3.64;i:1673445397;d:3.6683;i:1673445101;d:3.4826;}s:17:\"discovery_history\";a:100:{i:1673531131;d:5.8914;i:1673530028;d:6.295;i:1673519691;d:5.7064;i:1673498096;d:5.3521;i:1673476497;d:5.4895;i:1673454881;d:5.3037;i:1673433291;d:5.4454;i:1673411687;d:5.3391;i:1673390117;d:5.6308;i:1673377274;d:5.3295;i:1673376819;d:6.0867;i:1673375450;d:5.9583;i:1673368482;d:5.7566;i:1673346880;d:5.5169;i:1673325269;d:5.5563;i:1673303688;d:5.2663;i:1673282084;d:5.1622;i:1673260482;d:5.4396;i:1673238877;d:5.5964;i:1673217304;d:5.8349;i:1673195674;d:5.5891;i:1673174083;d:5.1827;i:1673152504;d:5.6365;i:1673130873;d:5.6514;i:1673109288;d:5.4569;i:1673087672;d:5.7175;i:1673066090;d:5.6451;i:1673044479;d:5.3042;i:1673022882;d:5.3776;i:1673001281;d:5.5593;i:1672979687;d:5.4479;i:1672958077;d:5.569;i:1672936502;d:6.3865;i:1672914871;d:5.202;i:1672893298;d:6.2653;i:1672871670;d:5.5365;i:1672850103;d:5.8594;i:1672828483;d:5.4179;i:1672806907;d:5.4698;i:1672785290;d:5.7058;i:1672763692;d:5.3895;i:1672742091;d:5.4034;i:1672720496;d:5.5845;i:1672698877;d:5.4801;i:1672677285;d:5.4033;i:1672655711;d:5.4926;i:1672634091;d:5.578;i:1672612489;d:5.2339;i:1672590885;d:5.4569;i:1672569295;d:5.6567;i:1672547696;d:5.9352;i:1672526091;d:5.4165;i:1672504496;d:5.4239;i:1672482872;d:5.5721;i:1672461290;d:5.5759;i:1672439695;d:5.5788;i:1672418074;d:5.3854;i:1672396498;d:6.5012;i:1672374881;d:5.8926;i:1672353308;d:5.2884;i:1672331671;d:5.2833;i:1672310099;d:6.2926;i:1672288488;d:5.2129;i:1672266921;d:5.5943;i:1672245284;d:5.5605;i:1672223717;d:5.6597;i:1672202063;d:5.3403;i:1672180497;d:6.0997;i:1672158867;d:5.7027;i:1672137301;d:5.9573;i:1672115666;d:5.3617;i:1672094098;d:6.0534;i:1672072522;d:5.261;i:1672050875;d:5.3214;i:1672029298;d:6.149;i:1672007683;d:5.3026;i:1671986101;d:6.2848;i:1671964491;d:5.2795;i:1671942891;d:5.3052;i:1671921285;d:5.1997;i:1671899670;d:5.4332;i:1671878099;d:6.7968;i:1671856509;d:5.853;i:1671834886;d:5.491;i:1671813305;d:5.6558;i:1671791720;d:5.3565;i:1671770113;d:5.7037;i:1671748490;d:5.3373;i:1671726916;d:5.3315;i:1671705288;d:5.6659;i:1671683688;d:5.542;i:1671662074;d:5.3202;i:1671640506;d:5.4196;i:1671618864;d:5.7851;i:1671597292;d:7.8601;i:1671575696;d:5.3115;i:1671554090;d:5.2979;i:1671532483;d:5.4168;i:1671510906;d:5.7053;i:1671489287;d:5.5655;}s:18:\"discovery_mod_perf\";a:18:{s:2:\"os\";d:0.098;s:4:\"mibs\";d:0.1772;s:5:\"ports\";d:0.4902;s:4:\"oids\";d:0.0017;s:12:\"ip-addresses\";d:0.3483;s:10:\"processors\";d:0.1232;s:8:\"mempools\";d:0.1334;s:9:\"inventory\";d:0.3609;s:15:\"printersupplies\";d:0.0011;s:7:\"sensors\";d:3.1228;s:7:\"storage\";d:0.185;s:10:\"neighbours\";d:0.3061;s:9:\"arp-table\";d:0.2098;s:14:\"mac-accounting\";d:0.0003;s:3:\"sla\";d:0.1374;s:16:\"virtual-machines\";d:0.0007;s:10:\"ucd-diskio\";d:0.1401;s:6:\"graphs\";d:0.0006;}}' WHERE `device_id` = '14']
SQL RUNTIME[0.01300907s]
#####  ups1.a1.nodefield.lan [14] completed discovery modules at 2023-01-12 15:45:36  #####

 o Discovery time       5.8914 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '542124' AND `process_name` = 'discovery.php' AND `device_id` = '14' AND `poller_id` = '0']
SQL RUNTIME[0.00636482s]
#####  Finished discovery run at 2023-01-12 15:45:36  #####


SQL[SELECT * FROM `groups` ORDER BY `entity_type`]
SQL RUNTIME[0.00067711s]

SQL[SELECT * FROM `groups_assoc`]
SQL RUNTIME[0.00042701s]

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") REGEXP 'trueflaw.lan$')]
SQL RUNTIME[0.00080180s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '1']
SQL RUNTIME[0.00073600s]
Group                             'Trueflaw': 28 existing, 28 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") REGEXP 'bonar.lan$')]
SQL RUNTIME[0.00068116s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '2']
SQL RUNTIME[0.00067019s]
Group                                'Bonar': 11 existing, 11 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") REGEXP 'a1.nodefield.lan$')]
SQL RUNTIME[0.00063896s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '3']
SQL RUNTIME[0.00078106s]
Group                    'Nodefield Astra 1': 76 existing, 76 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`hostname`, "") REGEXP 'nodefield.lan$')]
SQL RUNTIME[0.00077891s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '4']
SQL RUNTIME[0.00079489s]
Group                            'Nodefield': 86 existing, 86 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices` WHERE ( IFNULL(`devices`.`location`, '') IN ('DE,Frankfurt am Main,Linode','FI,Kirkkonummi,Masalanportti,A1','FI,Kirkkonummi,Masalanportti,A1.PVE','FI,Kirkkonummi,Masalanportti,A1.R1','FI,Kirkkonummi,Masalanportti,A1.R2','FI,Kirkkonummi,Masalanportti,A1.R3','FI,Kirkkonummi,Masalanportti,A1.TR1') AND( IFNULL(`devices`.`type`, '') = 'hypervisor' OR IFNULL(`devices`.`type`, '') = 'security' OR IFNULL(`devices`.`type`, '') = 'power' OR IFNULL(`devices`.`device_id`, '') IN ('2','145','3','144','4','143','50','51','54','55','62','142','7','8','9','49','140','14','70','18','19')))]
SQL RUNTIME[0.00132990s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '5']
SQL RUNTIME[0.00068808s]
Group                     'Critical devices': 28 existing, 28 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE (( IFNULL(`devices`.`device_id`, '') = '140' AND IFNULL(`ports`.`ifName`, "") LIKE '%suomicom%')) AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00269508s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '7']
SQL RUNTIME[0.00059295s]
Group                       'Critical ports': 1 existing, 1 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '5']
SQL RUNTIME[0.00074005s]

SQL[SELECT `probe_id`, `devices`.`device_id` as `device_id` FROM `probes` LEFT JOIN `devices` ON (`probes`.`device_id` = `devices`.`device_id`) WHERE ( `devices`.`device_id` IN ('2','3','4','8','9','14','18','19','30','31','32','33','49','50','51','54','55','59','60','62','70','73','110','140','142','143','144','145') OR( IFNULL(`devices`.`device_id`, '') IN ('50','51','142','49')))]
SQL RUNTIME[0.00091600s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '6']
SQL RUNTIME[0.00072408s]
Group                      'Critical probes': 22 existing, 22 new entries (+0/-0).

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00063205s]
Cached 13 alert rules.

SQL[SELECT * FROM `alert_assoc`]
SQL RUNTIME[0.00049305s]

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`ignore` = '0') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00384092s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '1']
SQL RUNTIME[0.00589800s]
Alert Checker                  'Port errors': 1176 existing, 1176 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '5']
SQL RUNTIME[0.00071788s]

SQL[SELECT `device_id` FROM `devices` WHERE ( `devices`.`ignore` = '0' AND `devices`.`device_id` NOT IN ('2','3','4','8','9','14','18','19','30','31','32','33','49','50','51','54','55','59','60','62','70','73','110','140','142','143','144','145'))]
SQL RUNTIME[0.00090599s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '2']
SQL RUNTIME[0.00134110s]
Alert Checker                  'Device down': 105 existing, 105 new entries (+0/-0).

SQL[SELECT `storage_id`, `devices`.`device_id` as `device_id` FROM `storage` LEFT JOIN `devices` ON (`storage`.`device_id` = `devices`.`device_id`) WHERE (( IFNULL(`devices`.`os`, '') IN ('freebsd','freenas','linux') AND `storage`.`storage_descr` = '/') OR( IFNULL(`devices`.`os`, '') = 'windows' AND IFNULL(`storage`.`storage_descr`, "") REGEXP '^C:.*')) AND `storage`.`storage_deleted` != '1']
SQL RUNTIME[0.00239491s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '3']
SQL RUNTIME[0.00107908s]
Alert Checker     'Root filesystem capacity': 67 existing, 67 new entries (+0/-0).

SQL[SELECT `probe_id`, `devices`.`device_id` as `device_id` FROM `probes` LEFT JOIN `devices` ON (`probes`.`device_id` = `devices`.`device_id`) WHERE ( `devices`.`ignore` = '0' AND `devices`.`disabled` = '0')]
SQL RUNTIME[0.00092697s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '4']
SQL RUNTIME[0.00091195s]
Alert Checker                 'Service down': 38 existing, 38 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`sensors`.`sensor_class`, '') = 'capacity' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '^fan.*$') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00281501s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '5']
SQL RUNTIME[0.00100493s]
Alert Checker                    'Fan issue': 0 existing, 0 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`port_descr_type` = 'transit') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00231099s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '6']
SQL RUNTIME[0.00891685s]
Alert Checker            'Transit port down': 17 existing, 17 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`sensors`.`sensor_class`, '') = 'capacity' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '^fan.*$') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00278306s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '7']
SQL RUNTIME[0.00061202s]
Alert Checker                  'Fan stalled': 0 existing, 0 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`sensors`.`sensor_class`, '') = 'voltage' AND IFNULL(`devices`.`type`, '') = 'power' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '^Input.*') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00279403s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '9']
SQL RUNTIME[0.00061607s]
Alert Checker  'UPS input line voltage down': 4 existing, 4 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE (( IFNULL(`sensors`.`sensor_class`, '') = 'temperature' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '.*inlet ambient.*') OR( IFNULL(`devices`.`type`, '') = 'power' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '^Temperature.*')) AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00584316s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '10']
SQL RUNTIME[0.00069118s]
Alert Checker       'High inlet temperature': 3 existing, 3 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '5']
SQL RUNTIME[0.00066805s]

SQL[SELECT `device_id` FROM `devices` WHERE ( `devices`.`device_id` IN ('2','3','4','8','9','14','18','19','30','31','32','33','49','50','51','54','55','59','60','62','70','73','110','140','142','143','144','145') AND `devices`.`disabled` = '0' AND `devices`.`ignore` = '0')]
SQL RUNTIME[0.00124097s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '11']
SQL RUNTIME[0.00081015s]
Alert Checker         'Critical device down': 26 existing, 26 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '6']
SQL RUNTIME[0.00071311s]

SQL[SELECT `probe_id`, `devices`.`device_id` as `device_id` FROM `probes` LEFT JOIN `devices` ON (`probes`.`device_id` = `devices`.`device_id`) WHERE ( `probes`.`probe_id` IN ('1','2','4','5','6','7','8','10','11','15','16','17','18','19','20','37','38','45','46','47','50','52'))]
SQL RUNTIME[0.00102901s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '12']
SQL RUNTIME[0.00227380s]
Alert Checker        'Critical service down': 22 existing, 22 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '7']
SQL RUNTIME[0.00055695s]

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`port_id` = '4597') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00065994s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '13']
SQL RUNTIME[0.00090003s]
Alert Checker        'Critical port is down': 1 existing, 1 new entries (+0/-0).

SQL[SELECT `sensor_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE ( IFNULL(`sensors`.`sensor_class`, '') = 'capacity' AND IFNULL(`devices`.`type`, '') = 'power' AND IFNULL(`sensors`.`sensor_descr`, "") REGEXP '^Battery Charge.*') AND `sensors`.`sensor_deleted` != '1']
SQL RUNTIME[0.00288010s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '14']
SQL RUNTIME[0.00064993s]
Alert Checker       'UPS battery charge low': 2 existing, 2 new entries (+0/-0).
./discovery.php: ups1.a1.nodefield.lan - 1 devices discovered in 6.012 secs

SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1673516730']
SQL RUNTIME[0.00055099s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       6.012 secs
 o Memory usage         10MB (peak: 10MB)
 o MySQL Usage          Cell[30/0.055s] Row[90/0.149s] Rows[111/0.25s] Column[14/0.023s] Update[6/0.03s] Insert[1/0.008s] Delete[2/0.009s] 
 o RRDTool Usage