DEBUG! DEFINITIONS loaded by: 0.0557969 ms DEFINITIONS in memory: 14.6MB SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00031996s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00012589s]  CMD[date "+%:z"]  CMD EXITCODE[0] CMD RUNTIME[0.004s] CMD EXITDELAY[10ms] STDOUT[ -04:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00013709s] DB timezone different from php timezone. Syncing.. SQL[SELECT version();] SQL RUNTIME[0.00009489s]  SQL[SET SESSION time_zone='+00:00';] SQL RUNTIME[0.00009394s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00022888s]  SQL[SELECT * FROM `config`] SQL RUNTIME[0.00026703s]  CMD[/sbin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.004s] CMD EXITDELAY[10ms] STDOUT[ /sbin/fping: Version 3.10 /sbin/fping: comments to david@schweikert.ch ] CACHE DISABLED. Disabled in config.  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Community Edition 22.5.12042 https://www.observium.org   CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.0231s] STDOUT[ Linux|3.10.0-1160.62.1.el7.x86_64|amd64|CentOS|7|vmware| ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0043s] STDOUT[ Python 2.7.5 ] SQL[SELECT version();] SQL RUNTIME[0.00015783s]  CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0071s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0087s] STDOUT[ RRDtool 1.7.1 Copyright by Tobias Oetiker ] CMD[/sbin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0032s] CMD EXITDELAY[10ms] STDOUT[ /sbin/fping: Version 3.10 /sbin/fping: comments to david@schweikert.ch ] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0039s] STDOUT[ ] CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0373s] STDOUT[ Apache/2.4.6 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00020003s]  SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00068593s]  ##### Software versions #####   o OS  Linux 3.10.0-1160.62.1.el7.x86_64 [amd64] (CentOS 7)  o Apache  2.4.6  o PHP  8.0.19 (OPcache: ENABLED)  o Python  2.7.5  o MariaDB  10.1.48-MariaDB (extension: mysqli 8.0.19)  o SNMP  NET-SNMP 5.7.2  o RRDtool  1.7.1  o Fping  3.10 (IPv4 only) ##### Memory Limit #####   o PHP  1GB ##### MariaDB mode #####   o MariaDB  NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MariaDB  utf8 ##### Timezones info #####   o Date  Tuesday, 07-Jun-22 19:06:56 UTC  o PHP  +00:00  o MariaDB  -04:00 ##### Fast Cache info #####   o Enabled  No  o Driver    o Total size  0B SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00035286s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'http_rate_https://www.observium.org';] SQL RUNTIME[0.00015402s]  SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'http_rate_https://www.observium.org')] SQL RUNTIME[0.00029302s]  SQL[UPDATE `observium_attribs` set `attrib_value` ='{\"2022-06-07\":5}' WHERE `attrib_type` = 'http_rate_https://www.observium.org'] SQL RUNTIME[0.00080299s] HTTP CURL cmd: curl --connect-timeout 15 -X POST -H 'Connection: close' -H 'Content-Type: application/x-www-form-urlencoded; charset=utf-8' -H 'Content-Length: 60' -H 'User-Agent: Observium CE/22.5.12042' -d 'stats=YToxOntzOjc6InZlcnNpb24iO3M6MTA6IjIyLjUuMTIwNDIiO30%3D' https://www.observium.org/versions.php REQUEST[https://www.observium.org/versions.php] REQUEST STATUS[TRUE] REQUEST RUNTIME[0.5381s] RESPONSE CODE[200 OK] Response [12068] valid: [stable->revision] regex [^\d+$]   /opt/observium/includes/common.inc.php:4208  array( [stable] => array( [version] => string(10) "22.5.12068" [revision] => string(5) "12068" [date] => string(10) "2022-05-31" ) [current] => array( [version] => string(10) "22.6.12096" [revision] => string(5) "12096" [date] => string(10) "2022-06-07" ) [ce] => array( [version] => string(7) "21.10.1" [revision] => string(5) "11666" [date] => string(10) "2021-10-13" ) ) SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver')] SQL RUNTIME[0.00049400s]  SQL[UPDATE `observium_attribs` set `attrib_value` ='21.10.1' WHERE `attrib_type` = 'latest_ver'] SQL RUNTIME[0.00099921s]  SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev')] SQL RUNTIME[0.00021100s]  SQL[UPDATE `observium_attribs` set `attrib_value` ='11666' WHERE `attrib_type` = 'latest_rev'] SQL RUNTIME[0.00072885s]  SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date')] SQL RUNTIME[0.00022697s]  SQL[UPDATE `observium_attribs` set `attrib_value` ='2021-10-13' WHERE `attrib_type` = 'latest_rev_date'] SQL RUNTIME[0.00089598s]  SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck')] SQL RUNTIME[0.00016499s]  SQL[UPDATE `observium_attribs` set `attrib_value` ='1654628816' WHERE `attrib_type` = 'last_versioncheck'] SQL RUNTIME[0.00074100s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00015306s] ##### Starting discovery run at 2022-06-07 19:06:56 #####   SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE '17hig2au01.cmhc.org' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00052094s]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.0437s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.318.1.3.27 .1.3.6.1.2.1.1.3.0 = 0:1:52:02.40 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901'] SQL RUNTIME[0.00035501s]  SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '1901' AND `poller_id` = '0'] SQL RUNTIME[0.00021911s]  SQL[DELETE FROM `observium_processes` WHERE `process_id` = '276861317'] SQL RUNTIME[0.00086403s]  SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('1845','discovery.php','52760','0','php ./discovery.php -d -h 17hig2au01.cmhc.org','1654628816','1901')] SQL RUNTIME[0.00075102s] ##### 17hig2au01.cmhc.org [1901] #####   o OS Type  apc  o OS Group  apc  o SNMP Version  v3  o Last discovery    o Last duration   seconds ##### Module Start: os #####   CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0425s] STDOUT[ APC Web/SNMP Management Card (MB:v4.2.9 PF:v1.3.3.1 PN:apc_hw21_aos_1.3.3.1.bin AF1:v1.3.3.1 AN1:apc_hw21_su_1.3.3.1.bin MN:0N-1557 HR:3 SN: 5A2144T30357 MD:11/04/2021) (Embedded PowerNet SNMP Agent SW v2.2 compatible) ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0415s] STDOUT[ .1.3.6.1.4.1.318.1.3.27 ] SNMP STATUS[TRUE] +-------------+--------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | OID | | +-------------+--------------------------------------------------------------------------------------------------------------------------------------------------------------------------+ | sysDescr | APC Web/SNMP Management Card (MB:v4.2.9 PF:v1.3.3.1 PN:apc_hw21_aos_1.3.3.1.bin AF1:v1.3.3.1 AN1:apc_hw21_su_1.3.3.1.bin MN:0N-1557 HR:3 SN: 5A2144T30357 MD:11/04/2021) | | | (Embedded PowerNet SNMP Agent SW v2.2 compatible) | | sysObjectID | .1.3.6.1.4.1.318.1.3.27 | +-------------+--------------------------------------------------------------------------------------------------------------------------------------------------------------------------+  o Detect OS matched (apc: APC OS):  +-------------+--------------------+-------------------------+ | OID | Matched definition | | +-------------+--------------------+-------------------------+ | sysObjectID | .1.3.6.1.4.1.318 | .1.3.6.1.4.1.318.1.3.27 | +-------------+--------------------+-------------------------+  o Duration  0.1265s ##### Module Start: mibs #####   CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']  CMD EXITCODE[0] CMD RUNTIME[0.0116s] STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' .1.3.6.1.2.1.1.9.1.2]  CMD EXITCODE[0] CMD RUNTIME[0.0445s] STDOUT[ .1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1 .1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.10.3.1.1 .1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.6.3.11.3.1.1 .1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.6.3.15.2.1.1 .1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.6.3.16.2.1.1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' sysORDescr]  CMD EXITCODE[0] CMD RUNTIME[0.0424s] STDOUT[ sysORDescr.1 = The MIB Module from SNMPv2 entities sysORDescr.2 = SNMP Management Architecture MIB sysORDescr.3 = Message Processing and Dispatching MIB sysORDescr.4 = USM User MIB sysORDescr.5 = VACM MIB ] SNMP STATUS[TRUE]  o MIBs discovered   SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00024986s]  +-----------------------+--------------------+-----------+----------------------------------+ | Identity | MIB | Source | Status | +-----------------------+--------------------+-----------+----------------------------------+ | .1.3.6.1.6.3.1 | SNMPv2-MIB | sysORID | MIB already defined | | .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined | | | PowerNet-MIB | Discovery | MIB defined for os but not found | | .1.3.6.1.6.3.11.3.1.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.15.2.1.1 | - | sysORID | Unknown Identity | | .1.3.6.1.6.3.16.2.1.1 | - | sysORID | Unknown Identity | +-----------------------+--------------------+-----------+----------------------------------+ SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00026107s] JSON DECODE[Not string passed] JSON RAW[  > $str /opt/observium/includes/common.inc.php:5511  null ] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '1901' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00019789s]    /opt/observium/includes/discovery/mibs.inc.php:313  array( [0] => string(12) "PowerNet-MIB" [1] => string(10) "SNMPv2-MIB" [2] => string(18) "SNMP-FRAMEWORK-MIB" [3] => string(6) "IF-MIB" [4] => string(13) "ADSL-LINE-MIB" [5] => string(13) "EtherLike-MIB" [6] => string(10) "ENTITY-MIB" [7] => string(17) "ENTITY-SENSOR-MIB" [8] => string(6) "IP-MIB" [9] => string(8) "IPV6-MIB" [10] => string(8) "LLDP-MIB" [11] => string(13) "CISCO-CDP-MIB" [12] => string(10) "PW-STD-MIB" [13] => string(15) "DISMAN-PING-MIB" )  o Duration  0.1123s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_vrf'] SQL RUNTIME[0.00019693s] ##### Module Start: vrf #####   SQL[SELECT COUNT(*) FROM `vrfs` WHERE `device_id` = '1901' AND 1] SQL RUNTIME[0.00020504s]  SQL[SELECT COUNT(*) FROM `ports` WHERE `device_id` = '1901' AND `ifVrf` IS NOT NULL AND 1] SQL RUNTIME[0.00039721s]   o Duration  0.0026s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_ports'] SQL RUNTIME[0.00036216s] ##### Module Start: ports #####   o Caching OIDs  ifDescr CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ifDescr]  CMD EXITCODE[0] CMD RUNTIME[0.0429s] STDOUT[ ifDescr.1 = LOOPBACK ifDescr.2 = vmac0 ] SNMP STATUS[TRUE] ifAlias CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ifAlias]  CMD EXITCODE[0] CMD RUNTIME[0.0495s] STDOUT[ ifAlias = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ifName CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ifName]  CMD EXITCODE[0] CMD RUNTIME[0.0451s] STDOUT[ ifName = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ifType CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ifType]  CMD EXITCODE[0] CMD RUNTIME[0.0447s] STDOUT[ ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ] SNMP STATUS[TRUE] ifOperStatus CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ifOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0423s] STDOUT[ ifOperStatus.1 = up ifOperStatus.2 = up ] SNMP STATUS[TRUE]    /opt/observium/includes/discovery/ports.inc.php:44  array( [1] => array( [ifDescr] => string(8) "LOOPBACK" [ifType] => string(16) "softwareLoopback" [ifOperStatus] => string(2) "up" ) [2] => array( [ifDescr] => string(5) "vmac0" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) )  o Caching DB   SQL[SELECT * FROM `ports` WHERE `device_id` = '1901'] SQL RUNTIME[0.00050497s] 2 ports  o Discovering ports  .. +---------+----------+--------+---------+------------------+-------------+---------+ | ifIndex | ifDescr | ifName | ifAlias | ifType | Oper Status | Ignored | +---------+----------+--------+---------+------------------+-------------+---------+ | 1 | LOOPBACK | | ... | softwareLoopback | up | no | | 2 | vmac0 | | ... | ethernetCsmacd | up | no | +---------+----------+--------+---------+------------------+-------------+---------+  o Duration  0.2362s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_ports-stack'] SQL RUNTIME[0.00022578s] Module [ports-stack] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_vlans'] SQL RUNTIME[0.00019407s] Module [vlans] disabled by os definition in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_oids'] SQL RUNTIME[0.00019717s] ##### Module Start: oids #####   SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '1901'] SQL RUNTIME[0.00022697s]  SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1'] SQL RUNTIME[0.00015998s]   o Duration  0.0017s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_ip-addresses'] SQL RUNTIME[0.00021315s] ##### Module Start: ip-addresses #####   SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00019717s] JSON DECODE[Not string passed] JSON RAW[   /opt/observium/includes/common.inc.php:5511  null ]  o IP-MIB   CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAdEntIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.046s] STDOUT[ ipAdEntIfIndex.10.10.160.21 = 2 ipAdEntIfIndex.127.0.0.1 = 1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAdEntNetMask]  CMD EXITCODE[0] CMD RUNTIME[0.0452s] STDOUT[ ipAdEntNetMask.10.10.160.21 = 255.255.248.0 ipAdEntNetMask.127.0.0.1 = 255.255.255.255 ] SNMP STATUS[TRUE] Added 10.10.160.21 .Added 127.0.0.1 . CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAddressIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0448s] STDOUT[ ipAddressIfIndex.ipv4."10.10.160.21" = 2 ipAddressIfIndex.ipv4."127.0.0.1" = 1 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAddressType]  CMD EXITCODE[0] CMD RUNTIME[0.0466s] STDOUT[ ipAddressType.ipv4."10.10.160.21" = unicast ipAddressType.ipv4."127.0.0.1" = unicast ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAddressPrefix]  CMD EXITCODE[0] CMD RUNTIME[0.0461s] STDOUT[ ipAddressPrefix.ipv4."10.10.160.21" = zeroDotZero ipAddressPrefix.ipv4."127.0.0.1" = zeroDotZero ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipAddressOrigin]  CMD EXITCODE[0] CMD RUNTIME[0.0472s] STDOUT[ ipAddressOrigin.ipv4."10.10.160.21" = manual ipAddressOrigin.ipv4."127.0.0.1" = manual ] SNMP STATUS[TRUE]   o IPV6-MIB   CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'17hig2au01.cmhc.org':'161' ipv6AddrEntry]  CMD EXITCODE[0] CMD RUNTIME[0.047s] STDOUT[ ipv6AddrEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]   o LLDP-MIB   SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '1901'] SQL RUNTIME[0.00033498s]  SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '1901' AND `ifIndex` = '2' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00019503s]  SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '388588'] SQL RUNTIME[0.00028086s]  SQL[SELECT EXISTS (SELECT 1 FROM `entity_attribs` WHERE `entity_type` = 'port' AND `device_id` = '1901')] SQL RUNTIME[0.00027680s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '388588'] SQL RUNTIME[0.00021601s]  SQL[SELECT * FROM `devices` WHERE `device_id` = '1901'] SQL RUNTIME[0.00030518s]  SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '1901'] SQL RUNTIME[0.00038695s]  SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.10.160.0/21'] SQL RUNTIME[0.00040579s]  SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '1901' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1] SQL RUNTIME[0.00017309s]  SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '388587'] SQL RUNTIME[0.00024486s]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '388587'] SQL RUNTIME[0.00021410s]  SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'] SQL RUNTIME[0.00041413s]  SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '1901'] SQL RUNTIME[0.00019598s]  SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '1901'] SQL RUNTIME[0.00019312s] +---------+----------+-------------+-----------------+----------------+----------+--------+ | ifIndex | ifDescr | IP: Version | Address | Network | Type | Origin | +---------+----------+-------------+-----------------+----------------+----------+--------+ | 2 | vmac0 | IPv4 | 10.10.160.21/21 | 10.10.160.0/21 | private | | | 1 | LOOPBACK | IPv4 | 127.0.0.1/32 | 127.0.0.1/32 | loopback | | +---------+----------+-------------+-----------------+----------------+----------+--------+  o Changes  2 unchanged  o Duration  0.3561s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_processors'] SQL RUNTIME[0.00027108s] ##### Module Start: processors #####   SQL[SELECT * FROM `processors` WHERE `device_id` = '1901'] SQL RUNTIME[0.00025702s]   o Duration  0.0023s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_mempools'] SQL RUNTIME[0.00022697s] ##### Module Start: mempools #####   SQL[SELECT * FROM `mempools` WHERE `device_id` = '1901'] SQL RUNTIME[0.00021100s]   o Duration  0.0015s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_inventory'] SQL RUNTIME[0.00026298s] ##### Module Start: inventory #####   o ENTITY-MIB  ENTITY-MIB CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'17hig2au01.cmhc.org':'161' entPhysicalEntry]  CMD EXITCODE[0] CMD RUNTIME[0.1194s] STDOUT[ entPhysicalEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '1901'] SQL RUNTIME[0.00032401s]   o Duration  0.1236s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_printersupplies'] SQL RUNTIME[0.00022388s] ##### Module Start: printersupplies #####   SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '1901'] SQL RUNTIME[0.00021601s]   o Duration  0.001s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '1901' AND `attrib_type` = 'discover_sensors'] SQL RUNTIME[0.00021195s] ##### Module Start: sensors #####   o PowerNet-MIB  upsBasicBatteryTimeOnBattery [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsBasicBatteryTimeOnBattery]  CMD EXITCODE[0] CMD RUNTIME[0.0915s] STDOUT[ upsBasicBatteryTimeOnBattery.0 = 0:0:00:00.00 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsBasicBatteryTimeOnBattery CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvConfigLowBatteryRunTime]  CMD EXITCODE[0] CMD RUNTIME[0.0978s] STDOUT[ upsAdvConfigLowBatteryRunTime.0 = 0:0:02:00.00 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsAdvConfigLowBatteryRunTime Timeticks converted 0:0:02:00.00 -> 120 Timeticks converted 0:0:00:00.00 -> 0 Discover sensor: [class: runtime, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.1.2.0, index: 0, type: PowerNet-MIB-upsBasicBatteryTimeOnBattery, descr: Running On Battery, scale: 0.016666666666667, limits: (, , 1, 2), CURRENT: 0, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsBasicBatteryTimeOnBattery' AND `sensor_index` = '0')] SQL RUNTIME[0.00073600s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsBasicBatteryTimeOnBattery' AND `sensor_index` = '0'] SQL RUNTIME[0.00045085s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14461' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00022388s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14461' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00020790s] .] upsAdvBatteryRunTimeRemaining [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvBatteryRunTimeRemaining]  CMD EXITCODE[0] CMD RUNTIME[0.0902s] STDOUT[ upsAdvBatteryRunTimeRemaining.0 = 0:0:42:22.00 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsAdvBatteryRunTimeRemaining Get cached Table OID: PowerNet-MIB::upsAdvConfigLowBatteryRunTime Timeticks converted 0:0:02:00.00 -> 120 Timeticks converted 0:0:42:22.00 -> 2542 Discover sensor: [class: runtime, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.2.3.0, index: 0, type: PowerNet-MIB-upsAdvBatteryRunTimeRemaining, descr: Battery Runtime Remaining, scale: 0.016666666666667, limits: (2, , , ), CURRENT: 42.366666666667, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsAdvBatteryRunTimeRemaining' AND `sensor_index` = '0')] SQL RUNTIME[0.00063610s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsAdvBatteryRunTimeRemaining' AND `sensor_index` = '0'] SQL RUNTIME[0.00045609s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14462' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00023580s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14462' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019503s] .RRD old file not found: '/opt/observium/rrd/17hig2au01.cmhc.org/sensor-runtime-apc-upsAdvBatteryRunTimeRemaining.0.rrd' ] upsHighPrecBatteryCapacity [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecBatteryCapacity]  CMD EXITCODE[0] CMD RUNTIME[0.0886s] STDOUT[ upsHighPrecBatteryCapacity.0 = 1000 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsHighPrecBatteryCapacity Discover sensor: [class: capacity, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.3.1.0, index: 0, type: PowerNet-MIB-upsHighPrecBatteryCapacity, descr: Battery Capacity, scale: 0.1, limits: (15, 30, , ), CURRENT: 100, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecBatteryCapacity' AND `sensor_index` = '0')] SQL RUNTIME[0.00062108s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecBatteryCapacity' AND `sensor_index` = '0'] SQL RUNTIME[0.00042510s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14463' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00021601s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14463' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00035381s] .RRD old file not found: '/opt/observium/rrd/17hig2au01.cmhc.org/sensor-capacity-apc-upsHighPrecBatteryCapacity.0.rrd' ] upsAdvBatteryCapacity [Excluded by valid exist: capacity->PowerNet-MIB-upsHighPrecBatteryCapacity !]upsHighPrecBatteryActualVoltage [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecBatteryActualVoltage]  CMD EXITCODE[0] CMD RUNTIME[0.0916s] STDOUT[ upsHighPrecBatteryActualVoltage.0 = 2175 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsHighPrecBatteryActualVoltage Discover sensor: [class: voltage, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.3.4.0, index: 0, type: PowerNet-MIB-upsHighPrecBatteryActualVoltage, descr: Battery Actual Voltage, scale: 0.1, limits: (, , , ), CURRENT: 217.5, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecBatteryActualVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00041986s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecBatteryActualVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00036979s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14464' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00023603s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14464' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019598s] .RRD old file not found: '/opt/observium/rrd/17hig2au01.cmhc.org/sensor-voltage-apc-upsHighPrecBatteryActualVoltage.0.rrd' ] upsAdvBatteryActualVoltage [Excluded by valid exist: voltage->PowerNet-MIB-upsHighPrecBatteryActualVoltage !]upsHighPrecInputLineVoltage [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecInputLineVoltage]  CMD EXITCODE[0] CMD RUNTIME[0.0855s] STDOUT[ upsHighPrecInputLineVoltage.0 = 2126 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsHighPrecInputLineVoltage Discover sensor: [class: voltage, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.3.3.1.0, index: 0, type: PowerNet-MIB-upsHighPrecInputLineVoltage, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: 212.6, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecInputLineVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00056505s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecInputLineVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00038004s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14465' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00022697s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14465' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019217s] .RRD old file not found: '/opt/observium/rrd/17hig2au01.cmhc.org/sensor-voltage-apc-upsHighPrecInputLineVoltage.0.rrd' ] upsAdvInputLineVoltage [Excluded by valid exist: voltage->PowerNet-MIB-upsHighPrecInputLineVoltage !]upsHighPrecOutputLoad [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecOutputLoad]  CMD EXITCODE[0] CMD RUNTIME[0.0873s] STDOUT[ upsHighPrecOutputLoad.0 = 167 ] SNMP STATUS[TRUE] Store in cache Table OID: PowerNet-MIB::upsHighPrecOutputLoad Discover sensor: [class: load, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.3.3.0, index: 0, type: PowerNet-MIB-upsHighPrecOutputLoad, descr: Output Load, scale: 0.1, limits: (, , 70, 85), CURRENT: 16.7, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecOutputLoad' AND `sensor_index` = '0')] SQL RUNTIME[0.00041699s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '1901' AND `sensor_type` = 'PowerNet-MIB-upsHighPrecOutputLoad' AND `sensor_index` = '0'] SQL RUNTIME[0.00036907s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14466' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00020099s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14466' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019908s] .RRD old file not found: '/opt/observium/rrd/17hig2au01.cmhc.org/sensor-capacity-apc-upsHighPrecOutputLoad.0.rrd' ] upsAdvOutputLoad [Excluded by valid exist: load->PowerNet-MIB-upsHighPrecOutputLoad !]xPDUMainInputVoltageLtoL [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUMainInputVoltageLtoN [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUBypassInputVoltageLtoL [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUBypassInputVoltageLtoN [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputFrequency [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputNeutralCurrent [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputTotalPower [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputTotalApparentPower [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputTotalPowerFactor [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputVoltageLtoL [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputVoltageLtoN [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputPhaseCurrent [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputPower [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputApparentPower [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemOutputPowerFactor [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUBranchBreakerCurrent [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]wirelessSensorStatusTemperature [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' wirelessSensorStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.0898s] STDOUT[ wirelessSensorStatusTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] wirelessSensorStatusHumidity [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' wirelessSensorStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.0902s] STDOUT[ wirelessSensorStatusTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] wirelessSensorStatusBattery [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' wirelessSensorStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.0885s] CMD EXITDELAY[10ms] STDOUT[ wirelessSensorStatusTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] wirelessSensorStatusRssi [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' wirelessSensorStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.0903s] STDOUT[ wirelessSensorStatusTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ]  o PowerNet-MIB  atsStatusSelectedSource [ CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' atsStatusCommStatus.0]  CMD EXITCODE[0] CMD RUNTIME[0.0849s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusRedundancyState [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatus5VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatus24VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatus24VSourceBPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusPlus12VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusMinus12VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusSwitchStatus [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusSourceAStatus [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusSourceBStatus [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusPhaseSyncStatus [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusHardwareStatus [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatus3dot3VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatus1Dot0VPowerSupply [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusVBoostSourceA [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]atsStatusVBoostSourceB [Get cached OID: PowerNet-MIB::atsStatusCommStatus.0 Excluded by not test condition: PowerNet-MIB::atsStatusCommStatus.0 [] eq [atsCommEstablished] !]emsInputContactStatusInputContactState [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsInputContactStatusEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0904s] STDOUT[ emsInputContactStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] emsOutputRelayStatusOutputRelayState [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsOutputRelayStatusEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0892s] STDOUT[ emsOutputRelayStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] emsOutletStatusOutletState [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsOutletStatusEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0904s] STDOUT[ emsOutletStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] emsAlarmDeviceStatusDeviceState [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsAlarmDeviceStatusDeviceState]  CMD EXITCODE[0] CMD RUNTIME[0.0911s] STDOUT[ emsAlarmDeviceStatusDeviceState = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsAlarmDeviceStatusDeviceName]  CMD EXITCODE[0] CMD RUNTIME[0.0941s] STDOUT[ emsAlarmDeviceStatusDeviceName = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] xPDUUPSInputVoltageLtoNPresent [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUSystemBreakerPosition [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUInputContactCurrentState [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUOutputRelayCurrentState [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUEPOMode [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUTransformTempStatus [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]xPDUCoolingFanStatus [Excluded by not test condition: Device sysObjectID [.1.3.6.1.4.1.318.1.3.27] match [.1.3.6.1.4.1.318.1.3.15] !]rPDUOutletStatusOutletState [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' rPDUOutletStatusEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0966s] STDOUT[ rPDUOutletStatusEntry = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] sPDUOutletCtl [ CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -Ih -OQUsb -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' sPDUOutletControlTable]  CMD EXITCODE[0] CMD RUNTIME[0.0925s] STDOUT[ sPDUOutletControlTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ]  o PowerNet-MIB   CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsPhaseNumInputs.0]  CMD EXITCODE[0] CMD RUNTIME[0.0837s] STDOUT[ No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsPhaseNumOutputs.0]  CMD EXITCODE[0] CMD RUNTIME[0.0837s] STDOUT[ No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Caching OIDs: upsHighPrecInput CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecInput]  CMD EXITCODE[0] CMD RUNTIME[0.0863s] STDOUT[ upsHighPrecInputLineVoltage.0 = 2128 upsHighPrecInputMaxLineVoltage.0 = 2131 upsHighPrecInputMinLineVoltage.0 = 2125 upsHighPrecInputFrequency.0 = 600 ] SNMP STATUS[TRUE] upsHighPrecOutput CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecOutput]  CMD EXITCODE[0] CMD RUNTIME[0.0897s] STDOUT[ upsHighPrecOutputVoltage.0 = 2078 upsHighPrecOutputFrequency.0 = 600 upsHighPrecOutputLoad.0 = 165 upsHighPrecOutputCurrent.0 = 39 upsHighPrecOutputEfficiency.0 = -2 upsHighPrecOutputEnergyUsage.0 = 55198 ] SNMP STATUS[TRUE] upsAdvInput CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvInput]  CMD EXITCODE[0] CMD RUNTIME[0.085s] STDOUT[ upsAdvInputLineVoltage.0 = 213 upsAdvInputMaxLineVoltage.0 = 213 upsAdvInputMinLineVoltage.0 = 212 upsAdvInputFrequency.0 = 60 upsAdvInputLineFailCause.0 = noTransfer ] SNMP STATUS[TRUE] upsAdvOutput CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvOutput]  CMD EXITCODE[0] CMD RUNTIME[0.0857s] STDOUT[ upsAdvOutputVoltage.0 = 208 upsAdvOutputFrequency.0 = 60 upsAdvOutputLoad.0 = 17 upsAdvOutputCurrent.0 = 4 upsAdvOutputActivePower.0 = 796 upsAdvOutputApparentPower.0 = 831 ] SNMP STATUS[TRUE] Discover sensor: [class: frequency, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.3.3.4.0, index: upsHighPrecInputFrequency.0, type: apc, descr: Input, scale: 0.1, limits: (, , , ), CURRENT: 60, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecInputFrequency.0')] SQL RUNTIME[0.00047398s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecInputFrequency.0'] SQL RUNTIME[0.00040698s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14467' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00020719s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14467' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00021291s] .Discover sensor: [class: voltage, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.3.1.0, index: upsHighPrecOutputVoltage.0, type: apc, descr: Output, scale: 0.1, limits: (, , , ), CURRENT: 207.8, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputVoltage.0')] SQL RUNTIME[0.00027895s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputVoltage.0'] SQL RUNTIME[0.00030708s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14468' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00020194s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14468' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019193s] .Discover sensor: [class: current, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.3.4.0, index: upsHighPrecOutputCurrent.0, type: apc, descr: Output, scale: 0.1, limits: (, , , ), CURRENT: 3.9, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputCurrent.0')] SQL RUNTIME[0.00056195s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputCurrent.0'] SQL RUNTIME[0.00061512s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14469' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00019383s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14469' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00020814s] .Discover sensor: [class: frequency, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.3.2.0, index: upsHighPrecOutputFrequency.0, type: apc, descr: Output, scale: 0.1, limits: (, , , ), CURRENT: 60, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputFrequency.0')] SQL RUNTIME[0.00037003s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecOutputFrequency.0'] SQL RUNTIME[0.00037813s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14470' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00019908s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14470' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019217s] .Discover counter: [class: energy, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.3.6.0, index: 0, descr: Output Energy, scale: 10, limits: (, , , ), CURRENT: 551980, , SQL[SELECT EXISTS (SELECT 1 FROM `counters` WHERE `device_id` = '1901' AND `counter_class` = 'energy' AND `counter_mib` = 'PowerNet-MIB' AND `counter_object` = 'upsHighPrecOutputEnergyUsage' AND `counter_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00026703s]  SQL[SELECT * FROM `counters` WHERE `device_id` = '1901' AND `counter_class` = 'energy' AND `counter_mib` = 'PowerNet-MIB' AND `counter_object` = 'upsHighPrecOutputEnergyUsage' AND `counter_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00030708s] .upsHighPrecBattery CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsHighPrecBattery]  CMD EXITCODE[0] CMD RUNTIME[0.3759s] STDOUT[ upsHighPrecBatteryCapacity.0 = 1000 upsHighPrecBatteryTemperature.0 = 200 upsHighPrecBatteryActualVoltage.0 = 2178 upsHighPrecBatteryPackTableSize.0 = 11 upsHighPrecBatteryPackIndex.1.1.1 = 1 upsHighPrecBatteryPackIndex.1.1.2 = 1 upsHighPrecBatteryPackIndex.2.1.1 = 2 upsHighPrecBatteryPackIndex.2.1.2 = 2 upsHighPrecBatteryPackIndex.3.1.1 = 3 upsHighPrecBatteryPackIndex.3.1.2 = 3 upsHighPrecBatteryPackIndex.4.1.1 = 4 upsHighPrecBatteryPackIndex.4.1.2 = 4 upsHighPrecBatteryPackIndex.5.1.1 = 5 upsHighPrecBatteryPackIndex.5.1.2 = 5 upsHighPrecBatteryPackIndex.6.1.1 = 6 upsHighPrecBatteryPackIndex.6.1.2 = 6 upsHighPrecBatteryPackIndex.7.1.1 = 7 upsHighPrecBatteryPackIndex.7.1.2 = 7 upsHighPrecBatteryPackIndex.8.1.1 = 8 upsHighPrecBatteryPackIndex.8.1.2 = 8 upsHighPrecBatteryPackIndex.9.1.1 = 9 upsHighPrecBatteryPackIndex.9.1.2 = 9 upsHighPrecBatteryPackIndex.10.1.1 = 10 upsHighPrecBatteryPackIndex.10.1.2 = 10 upsHighPrecBatteryPackIndex.11.1.1 = 11 upsHighPrecBatteryPackIndex.11.1.2 = 11 upsHighPrecBatteryCartridgeIndex.1.1.1 = 1 upsHighPrecBatteryCartridgeIndex.1.1.2 = 2 upsHighPrecBatteryCartridgeIndex.2.1.1 = 1 upsHighPrecBatteryCartridgeIndex.2.1.2 = 2 upsHighPrecBatteryCartridgeIndex.3.1.1 = 1 upsHighPrecBatteryCartridgeIndex.3.1.2 = 2 upsHighPrecBatteryCartridgeIndex.4.1.1 = 1 upsHighPrecBatteryCartridgeIndex.4.1.2 = 2 upsHighPrecBatteryCartridgeIndex.5.1.1 = 1 upsHighPrecBatteryCartridgeIndex.5.1.2 = 2 upsHighPrecBatteryCartridgeIndex.6.1.1 = 1 upsHighPrecBatteryCartridgeIndex.6.1.2 = 2 upsHighPrecBatteryCartridgeIndex.7.1.1 = 1 upsHighPrecBatteryCartridgeIndex.7.1.2 = 2 upsHighPrecBatteryCartridgeIndex.8.1.1 = 1 upsHighPrecBatteryCartridgeIndex.8.1.2 = 2 upsHighPrecBatteryCartridgeIndex.9.1.1 = 1 upsHighPrecBatteryCartridgeIndex.9.1.2 = 2 upsHighPrecBatteryCartridgeIndex.10.1.1 = 1 upsHighPrecBatteryCartridgeIndex.10.1.2 = 2 upsHighPrecBatteryCartridgeIndex.11.1.1 = 1 upsHighPrecBatteryCartridgeIndex.11.1.2 = 2 upsHighPrecBatteryPackFirmwareRevision.1.1.1 = "BMC 18.7" upsHighPrecBatteryPackFirmwareRevision.1.1.2 = "BMC 18.7" upsHighPrecBatteryPackFirmwareRevision.2.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.2.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.3.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.3.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.4.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.4.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.5.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.5.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.6.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.6.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.7.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.7.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.8.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.8.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.9.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.9.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.10.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.10.1.2 = "" upsHighPrecBatteryPackFirmwareRevision.11.1.1 = "" upsHighPrecBatteryPackFirmwareRevision.11.1.2 = "" upsHighPrecBatteryPackSerialNumber.1.1.1 = " " upsHighPrecBatteryPackSerialNumber.1.1.2 = " " upsHighPrecBatteryPackSerialNumber.2.1.1 = "" upsHighPrecBatteryPackSerialNumber.2.1.2 = "" upsHighPrecBatteryPackSerialNumber.3.1.1 = "" upsHighPrecBatteryPackSerialNumber.3.1.2 = "" upsHighPrecBatteryPackSerialNumber.4.1.1 = "" upsHighPrecBatteryPackSerialNumber.4.1.2 = "" upsHighPrecBatteryPackSerialNumber.5.1.1 = "" upsHighPrecBatteryPackSerialNumber.5.1.2 = "" upsHighPrecBatteryPackSerialNumber.6.1.1 = "" upsHighPrecBatteryPackSerialNumber.6.1.2 = "" upsHighPrecBatteryPackSerialNumber.7.1.1 = "" upsHighPrecBatteryPackSerialNumber.7.1.2 = "" upsHighPrecBatteryPackSerialNumber.8.1.1 = "" upsHighPrecBatteryPackSerialNumber.8.1.2 = "" upsHighPrecBatteryPackSerialNumber.9.1.1 = "" upsHighPrecBatteryPackSerialNumber.9.1.2 = "" upsHighPrecBatteryPackSerialNumber.10.1.1 = "" upsHighPrecBatteryPackSerialNumber.10.1.2 = "" upsHighPrecBatteryPackSerialNumber.11.1.1 = "" upsHighPrecBatteryPackSerialNumber.11.1.2 = "" upsHighPrecBatteryPackTemperature.1.1.1 = 200 upsHighPrecBatteryPackTemperature.1.1.2 = 200 upsHighPrecBatteryPackTemperature.2.1.1 = 0 upsHighPrecBatteryPackTemperature.2.1.2 = 0 upsHighPrecBatteryPackTemperature.3.1.1 = 0 upsHighPrecBatteryPackTemperature.3.1.2 = 0 upsHighPrecBatteryPackTemperature.4.1.1 = 0 upsHighPrecBatteryPackTemperature.4.1.2 = 0 upsHighPrecBatteryPackTemperature.5.1.1 = 0 upsHighPrecBatteryPackTemperature.5.1.2 = 0 upsHighPrecBatteryPackTemperature.6.1.1 = 0 upsHighPrecBatteryPackTemperature.6.1.2 = 0 upsHighPrecBatteryPackTemperature.7.1.1 = 0 upsHighPrecBatteryPackTemperature.7.1.2 = 0 upsHighPrecBatteryPackTemperature.8.1.1 = 0 upsHighPrecBatteryPackTemperature.8.1.2 = 0 upsHighPrecBatteryPackTemperature.9.1.1 = 0 upsHighPrecBatteryPackTemperature.9.1.2 = 0 upsHighPrecBatteryPackTemperature.10.1.1 = 0 upsHighPrecBatteryPackTemperature.10.1.2 = 0 upsHighPrecBatteryPackTemperature.11.1.1 = 0 upsHighPrecBatteryPackTemperature.11.1.2 = 0 upsHighPrecBatteryPackStatus.1.1.1 = "" upsHighPrecBatteryPackStatus.1.1.2 = "" upsHighPrecBatteryPackStatus.2.1.1 = "" upsHighPrecBatteryPackStatus.2.1.2 = "" upsHighPrecBatteryPackStatus.3.1.1 = "" upsHighPrecBatteryPackStatus.3.1.2 = "" upsHighPrecBatteryPackStatus.4.1.1 = "" upsHighPrecBatteryPackStatus.4.1.2 = "" upsHighPrecBatteryPackStatus.5.1.1 = "" upsHighPrecBatteryPackStatus.5.1.2 = "" upsHighPrecBatteryPackStatus.6.1.1 = "" upsHighPrecBatteryPackStatus.6.1.2 = "" upsHighPrecBatteryPackStatus.7.1.1 = "" upsHighPrecBatteryPackStatus.7.1.2 = "" upsHighPrecBatteryPackStatus.8.1.1 = "" upsHighPrecBatteryPackStatus.8.1.2 = "" upsHighPrecBatteryPackStatus.9.1.1 = "" upsHighPrecBatteryPackStatus.9.1.2 = "" upsHighPrecBatteryPackStatus.10.1.1 = "" upsHighPrecBatteryPackStatus.10.1.2 = "" upsHighPrecBatteryPackStatus.11.1.1 = "" upsHighPrecBatteryPackStatus.11.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.1.1.1 = "1000000000000000" upsHighPrecBatteryPackCartridgeHealth.1.1.2 = "0000000000000000" upsHighPrecBatteryPackCartridgeHealth.2.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.2.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.3.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.3.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.4.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.4.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.5.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.5.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.6.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.6.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.7.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.7.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.8.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.8.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.9.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.9.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.10.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.10.1.2 = "" upsHighPrecBatteryPackCartridgeHealth.11.1.1 = "" upsHighPrecBatteryPackCartridgeHealth.11.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.1.1.1 = "11/03/2026" upsHighPrecBatteryPackCartridgeReplaceDate.1.1.2 = "01/01/2000" upsHighPrecBatteryPackCartridgeReplaceDate.2.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.2.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.3.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.3.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.4.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.4.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.5.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.5.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.6.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.6.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.7.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.7.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.8.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.8.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.9.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.9.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.10.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.10.1.2 = "" upsHighPrecBatteryPackCartridgeReplaceDate.11.1.1 = "" upsHighPrecBatteryPackCartridgeReplaceDate.11.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.1.1.1 = "11/09/2021" upsHighPrecBatteryPackCartridgeInstallDate.1.1.2 = "01/01/2000" upsHighPrecBatteryPackCartridgeInstallDate.2.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.2.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.3.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.3.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.4.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.4.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.5.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.5.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.6.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.6.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.7.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.7.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.8.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.8.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.9.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.9.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.10.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.10.1.2 = "" upsHighPrecBatteryPackCartridgeInstallDate.11.1.1 = "" upsHighPrecBatteryPackCartridgeInstallDate.11.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.1.1.1 = "0000000000000000" upsHighPrecBatteryPackCartridgeStatus.1.1.2 = "0000000000000000" upsHighPrecBatteryPackCartridgeStatus.2.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.2.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.3.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.3.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.4.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.4.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.5.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.5.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.6.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.6.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.7.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.7.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.8.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.8.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.9.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.9.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.10.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.10.1.2 = "" upsHighPrecBatteryPackCartridgeStatus.11.1.1 = "" upsHighPrecBatteryPackCartridgeStatus.11.1.2 = "" upsHighPrecBatteryPackOnlyTableSize.0 = 7 upsHighPrecBatteryPackOnlyIndex.1.1 = 1 upsHighPrecBatteryPackOnlyIndex.2.1 = 2 upsHighPrecBatteryPackOnlyIndex.3.1 = 3 upsHighPrecBatteryPackOnlyIndex.4.1 = 4 upsHighPrecBatteryPackOnlyIndex.5.1 = 5 upsHighPrecBatteryPackOnlyIndex.6.1 = 6 upsHighPrecBatteryPackOnlyIndex.7.1 = 7 upsHighPrecBatteryPackOnlyIndex.8.1 = 8 upsHighPrecBatteryPackOnlyFirmwareRevision.1.1 = "BMC 18.7" upsHighPrecBatteryPackOnlyFirmwareRevision.2.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.3.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.4.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.5.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.6.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.7.1 = "" upsHighPrecBatteryPackOnlyFirmwareRevision.8.1 = "" upsHighPrecBatteryPackOnlySerialNumber.1.1 = " " upsHighPrecBatteryPackOnlySerialNumber.2.1 = "" upsHighPrecBatteryPackOnlySerialNumber.3.1 = "" upsHighPrecBatteryPackOnlySerialNumber.4.1 = "" upsHighPrecBatteryPackOnlySerialNumber.5.1 = "" upsHighPrecBatteryPackOnlySerialNumber.6.1 = "" upsHighPrecBatteryPackOnlySerialNumber.7.1 = "" upsHighPrecBatteryPackOnlySerialNumber.8.1 = "" upsHighPrecBatteryPackOnlyTemperature.1.1 = 200 upsHighPrecBatteryPackOnlyTemperature.2.1 = 0 upsHighPrecBatteryPackOnlyTemperature.3.1 = 0 upsHighPrecBatteryPackOnlyTemperature.4.1 = 0 upsHighPrecBatteryPackOnlyTemperature.5.1 = 0 upsHighPrecBatteryPackOnlyTemperature.6.1 = 0 upsHighPrecBatteryPackOnlyTemperature.7.1 = 0 upsHighPrecBatteryPackOnlyTemperature.8.1 = 0 upsHighPrecBatteryPackOnlyStatus.1.1 = "0000000000000000" upsHighPrecBatteryPackOnlyStatus.2.1 = "" upsHighPrecBatteryPackOnlyStatus.3.1 = "" upsHighPrecBatteryPackOnlyStatus.4.1 = "" upsHighPrecBatteryPackOnlyStatus.5.1 = "" upsHighPrecBatteryPackOnlyStatus.6.1 = "" upsHighPrecBatteryPackOnlyStatus.7.1 = "" upsHighPrecBatteryPackOnlyStatus.8.1 = "" upsHighPrecBatteryPackOnlyHealth.1.1 = "0000000000000000" upsHighPrecBatteryPackOnlyHealth.2.1 = "" upsHighPrecBatteryPackOnlyHealth.3.1 = "" upsHighPrecBatteryPackOnlyHealth.4.1 = "" upsHighPrecBatteryPackOnlyHealth.5.1 = "" upsHighPrecBatteryPackOnlyHealth.6.1 = "" upsHighPrecBatteryPackOnlyHealth.7.1 = "" upsHighPrecBatteryPackOnlyHealth.8.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.1.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.2.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.3.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.4.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.5.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.6.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.7.1 = "" upsHighPrecBatteryPackOnlyReplaceDate.8.1 = "" upsHighPrecBatteryPackOnlyInstallDate.1.1 = "" upsHighPrecBatteryPackOnlyInstallDate.2.1 = "" upsHighPrecBatteryPackOnlyInstallDate.3.1 = "" upsHighPrecBatteryPackOnlyInstallDate.4.1 = "" upsHighPrecBatteryPackOnlyInstallDate.5.1 = "" upsHighPrecBatteryPackOnlyInstallDate.6.1 = "" upsHighPrecBatteryPackOnlyInstallDate.7.1 = "" upsHighPrecBatteryPackOnlyInstallDate.8.1 = "" ] SNMP STATUS[TRUE] upsAdvBattery CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvBattery]  CMD EXITCODE[0] CMD RUNTIME[0.0861s] STDOUT[ upsAdvBatteryCapacity.0 = 100 upsAdvBatteryTemperature.0 = 20 upsAdvBatteryRunTimeRemaining.0 = 0:0:42:22.00 upsAdvBatteryReplaceIndicator.0 = noBatteryNeedsReplacing upsAdvBatteryNumOfBattPacks.0 = 1 upsAdvBatteryActualVoltage.0 = 218 upsAdvBatteryInternalSKU.0 = "APCRBC140" upsAdvBatteryExternalSKU.0 = "APCRBC140" upsAdvBatteryRecommendedReplaceDate.0 = "11/03/2026" ] SNMP STATUS[TRUE] upsBasicBattery CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsBasicBattery]  CMD EXITCODE[0] CMD RUNTIME[0.0847s] STDOUT[ upsBasicBatteryStatus.0 = batteryNormal upsBasicBatteryTimeOnBattery.0 = 0:0:00:00.00 upsBasicBatteryLastReplaceDate.0 = "11/09/2021" ] SNMP STATUS[TRUE] Discover sensor: [class: temperature, device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.3.2.0, index: upsHighPrecBatteryTemperature.0, type: apc, descr: Battery, scale: 0.1, limits: (, , , ), CURRENT: 20, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecBatteryTemperature.0')] SQL RUNTIME[0.00035691s]  SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '1901' AND `sensor_type` = 'apc' AND `sensor_index` = 'upsHighPrecBatteryTemperature.0'] SQL RUNTIME[0.00030994s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14471' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00019503s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '14471' AND `attrib_type` = 'oid_scale_si'] SQL RUNTIME[0.00019813s] .Discover status: [device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.2.2.4.0, index: upsAdvBatteryReplaceIndicator.0, type: powernet-upsbatteryreplace-state, descr: Battery Replace (last 2021-11-09), CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upsbatteryreplace-state' AND `status_index` = 'upsAdvBatteryReplaceIndicator.0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00036812s]  SQL[SELECT * FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upsbatteryreplace-state' AND `status_index` = 'upsAdvBatteryReplaceIndicator.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00037503s] . CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsAdvTestDiagnosticSchedule.0 upsAdvTestDiagnosticsResults.0 upsAdvTestLastDiagnosticsDate.0]  CMD EXITCODE[0] CMD RUNTIME[0.084s] STDOUT[ upsAdvTestDiagnosticSchedule.0 = biweeklySinceLastTest upsAdvTestDiagnosticsResults.0 = ok upsAdvTestLastDiagnosticsDate.0 = "06/02/2022" ] SNMP STATUS[TRUE] Discover status: [device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.7.2.3.0, index: upsAdvTestDiagnosticsResults.0, type: powernet-upstest-state, descr: Diagnostics Results (last 2022-06-02), CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upstest-state' AND `status_index` = 'upsAdvTestDiagnosticsResults.0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00033402s]  SQL[SELECT * FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upstest-state' AND `status_index` = 'upsAdvTestDiagnosticsResults.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00026202s] . CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' upsBasicOutputStatus.0]  CMD EXITCODE[0] CMD RUNTIME[0.0827s] STDOUT[ onLine ] SNMP STATUS[TRUE] Discover status: [device: 17hig2au01.cmhc.org, oid: .1.3.6.1.4.1.318.1.1.1.4.1.1.0, index: upsBasicOutputStatus.0, type: powernet-upsbasicoutput-state, descr: Output Status, CURRENT: 2, , power] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upsbasicoutput-state' AND `status_index` = 'upsBasicOutputStatus.0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00032711s]  SQL[SELECT * FROM `status` WHERE `device_id` = '1901' AND `status_type` = 'powernet-upsbasicoutput-state' AND `status_index` = 'upsBasicOutputStatus.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00025797s] . CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' atsNumInputs.0]  CMD EXITCODE[0] CMD RUNTIME[0.0899s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' atsNumOutputs.0]  CMD EXITCODE[0] CMD RUNTIME[0.0861s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' rPDUIdentDeviceNumOutlets.0]  CMD EXITCODE[0] CMD RUNTIME[0.0834s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' rPDULoadDevNumBanks.0]  CMD EXITCODE[0] CMD RUNTIME[0.0855s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' rPDULoadDevice]  CMD EXITCODE[0] CMD RUNTIME[0.0877s] STDOUT[ rPDULoadDevice = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OsqnU -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' isxModularDistSysVoltageLtoN]  CMD EXITCODE[0] CMD RUNTIME[0.0934s] STDOUT[ .1.3.6.1.4.1.318.1.1.22.4.1.15.1.3 No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OsqnU -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' isxModularDistModuleBreakerCurrent]  CMD EXITCODE[0] CMD RUNTIME[0.0899s] STDOUT[ .1.3.6.1.4.1.318.1.1.22.2.4.1.9 No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  emsProbeStatusTable CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsProbeStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.092s] STDOUT[ emsProbeStatusTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  CMD[/usr/bin/snmpget -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' emsStatusSysTempUnits.0]  CMD EXITCODE[0] CMD RUNTIME[0.0889s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] iemConfigProbesTable CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' iemConfigProbesTable]  CMD EXITCODE[0] CMD RUNTIME[0.0923s] STDOUT[ iemConfigProbesTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] iemStatusProbesTable CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' iemStatusProbesTable]  CMD EXITCODE[0] CMD RUNTIME[0.095s] STDOUT[ iemStatusProbesTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]  uioSensorStatusTable CMD[/usr/bin/snmpbulkwalk -v3 -l 'authPriv' -n '' -x *** -X *** -a *** -A *** -u *** -Pud -OQUs -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'17hig2au01.cmhc.org':'161' uioSensorStatusTable]  CMD EXITCODE[0] CMD RUNTIME[0.0957s] STDOUT[ uioSensorStatusPortID.1.1 = 1 uioSensorStatusSensorID.1.1 = 1 uioSensorStatusSensorName.1.1 = "Port 1 Temp 1" uioSensorStatusSensorLocation.1.1 = "Port 1" uioSensorStatusTemperatureDegF.1.1 = 64 uioSensorStatusTemperatureDegC.1.1 = 18 uioSensorStatusHumidity.1.1 = -1 uioSensorStatusViolationStatus.1.1 = 0 uioSensorStatusAlarmStatus.1.1 = uioNormal uioSensorStatusCommStatus.1.1 = commsOK ] SNMP STATUS[TRUE]  Fatal error: Uncaught TypeError: in_array(): Argument #2 ($haystack) must be of type array, null given in /opt/observium/includes/discovery/sensors/powernet-mib.inc.php:1438 Stack trace: #0 /opt/observium/includes/discovery/sensors/powernet-mib.inc.php(1438): in_array('Port 1 Temp 1', NULL) #1 /opt/observium/includes/include-dir-mib.inc.php(48): include('/opt/observium/...') #2 /opt/observium/includes/discovery/sensors.inc.php(52): include('/opt/observium/...') #3 /opt/observium/includes/discovery/functions.inc.php(977): include('/opt/observium/...') #4 /opt/observium/discovery.php(198): discover_device(Array, Array) #5 {main} thrown in /opt/observium/includes/discovery/sensors/powernet-mib.inc.php on line 1438