DEBUG! CMD[/usr/bin/svn info /opt/observium]  CMD EXITCODE[0] CMD RUNTIME[0.0197s] CMD EXITDELAY[10ms] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 11769 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 11769 Last Changed Date: 2021-11-29 10:42:49 -0500 (Mon, 29 Nov 2021) ] DEFINITIONS loaded by: 0.1567 ms DEFINITIONS in memory: 3.19MB SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00048304s]  SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00023794s]  SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00018287s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY, NO_ZERO_DATE, NO_ZERO_IN_DATE, ERROR_FOR_DIVISION_BY_ZERO CMD[date "+%:z"]  CMD EXITCODE[0] CMD RUNTIME[0.0026s] CMD EXITDELAY[10ms] STDOUT[ -05:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00032616s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00033808s]  SQL[SELECT * FROM `config`] SQL RUNTIME[0.00033522s]  ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 21.11.11769 https://www.observium.org   CMD[/opt/observium/scripts/distro]  CMD EXITCODE[0] CMD RUNTIME[0.0216s] STDOUT[ Linux|4.15.0-162-generic|amd64|Ubuntu|18.04|microsoft| ] CMD[/usr/bin/env python --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0045s] CMD EXITDELAY[10ms] STDOUT[ Python 2.7.17 ] SQL[SELECT version();] SQL RUNTIME[0.00020790s]  CMD[/usr/bin/snmpget --version 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.004s] CMD EXITDELAY[10ms] STDOUT[ NET-SNMP version: 5.7.3 ] CMD[/usr/bin/rrdtool --version | head -n1]  CMD EXITCODE[0] CMD RUNTIME[0.0132s] STDOUT[ RRDtool 1.7.0 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1]  CMD EXITCODE[0] CMD RUNTIME[0.0031s] CMD EXITDELAY[10ms] STDOUT[ /usr/bin/fping: Version 4.0 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']  CMD EXITCODE[0] CMD RUNTIME[0.0587s] STDOUT[ Apache/2.4.29 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00034785s]  SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00326180s]  ##### Software versions #####   o OS  Linux 4.15.0-162-generic [amd64] (Ubuntu 18.04)  o Apache  2.4.29  o PHP  7.2.24-0ubuntu0.18.04.10 (OPcache: ENABLED)  o Python  2.7.17  o MySQL  5.7.36-0ubuntu0.18.04.1 (extension: mysqli 5.0.12-dev)  o SNMP  NET-SNMP 5.7.3  o RRDtool  1.7.0  o Fping  4.0 (IPv4 and IPv6) ##### Memory Limit #####   o PHP  Unlimited ##### MySQL mode #####   o MySQL  NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info #####   o PHP  UTF-8  o MySQL  utf8 ##### Timezones info #####   o Date  Monday, 29-Nov-21 13:00:30 EST  o PHP  -05:00  o MySQL  -05:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00035214s]  SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00043297s] ##### Starting discovery run at 2021-11-29 13:00:30 #####   SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'roomalert.bluetowertech.local' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00081515s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' .1.3.6.1.2.1.1.2.0 .1.3.6.1.2.1.1.3.0]  CMD EXITCODE[0] CMD RUNTIME[0.04s] STDOUT[ .1.3.6.1.2.1.1.2.0 = .1.3.6.1.4.1.20916.1.8 .1.3.6.1.2.1.1.3.0 = 0:1:13:15.56 ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122'] SQL RUNTIME[0.00108981s]  SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '122' AND `poller_id` = '0'] SQL RUNTIME[0.00036502s]  SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('20803','discovery.php','16357','0','php ./discovery.php -d -h roomalert.bluetowertech.local','1638208830','122')] SQL RUNTIME[0.00387192s] ##### roomalert.bluetowertech.local [122] #####   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' sysDescr.0]  CMD EXITCODE[0] CMD RUNTIME[0.0287s] STDOUT[ RA32-123398 ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' sysObjectID.0]  CMD EXITCODE[0] CMD RUNTIME[0.0264s] STDOUT[ .1.3.6.1.4.1.20916.1.8 ] SNMP STATUS[TRUE] +-------------+------------------------+ | OID | | +-------------+------------------------+ | sysDescr | RA32-123398 | | sysObjectID | .1.3.6.1.4.1.20916.1.8 | +-------------+------------------------+ CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m WOWZA-STREAMING-ENGINE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/wowza 'udp':'roomalert.bluetowertech.local':'161' serverCounterGetVersion.1]  CMD EXITCODE[2] CMD RUNTIME[0.0248s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: WOWZA-STREAMING-ENGINE-MIB::serverCounterGetVersion.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: WOWZA-STREAMING-ENGINE-MIB::serverCounterGetVersion.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m BETTER-NETWORKS-ETHERNETBOX-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/messpc 'udp':'roomalert.bluetowertech.local':'161' version.0]  CMD EXITCODE[2] CMD RUNTIME[0.0225s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: BETTER-NETWORKS-ETHERNETBOX-MIB::version.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: BETTER-NETWORKS-ETHERNETBOX-MIB::version.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m Printer-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' prtGeneralServicePerson.1]  CMD EXITCODE[2] CMD RUNTIME[0.031s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: Printer-MIB::prtGeneralServicePerson.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: Printer-MIB::prtGeneralServicePerson.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m ENTITY-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhysicalDescr.1]  CMD EXITCODE[2] CMD RUNTIME[0.0337s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: ENTITY-MIB::entPhysicalDescr.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: ENTITY-MIB::entPhysicalDescr.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m HIK-DEVICE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/hikvision 'udp':'roomalert.bluetowertech.local':'161' deviceType.0]  CMD EXITCODE[2] CMD RUNTIME[0.0227s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: HIK-DEVICE-MIB::deviceType.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: HIK-DEVICE-MIB::deviceType.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m NSCRTV-HFCEMS-COMMON-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/nscrtv 'udp':'roomalert.bluetowertech.local':'161' commonDeviceVendorInfo.1]  CMD EXITCODE[2] CMD RUNTIME[0.0214s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: NSCRTV-HFCEMS-COMMON-MIB::commonDeviceVendorInfo.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: NSCRTV-HFCEMS-COMMON-MIB::commonDeviceVendorInfo.1 Including freebsd.inc.php Including broadcom.inc.php Including linux.inc.php Including nxp-mqx-rtcs.inc.php Including solaris.inc.php  o OS Type  generic  o OS Group  unix  o SNMP Version  v1  o Last discovery  2021-11-29 12:58:19  o Last duration  3.47 seconds ##### Module Start: os #####    o Duration  0.0002s ##### Module Start: mibs #####   CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']  CMD EXITCODE[0] CMD RUNTIME[0.0184s] CMD EXITDELAY[10ms] STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' .1.3.6.1.2.1.1.9.1.2]  CMD EXITCODE[0] CMD RUNTIME[0.0228s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' sysORDescr]  CMD EXITCODE[0] CMD RUNTIME[0.023s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ospfAdminStat.0]  CMD EXITCODE[2] CMD RUNTIME[0.0284s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: OSPF-MIB::ospfAdminStat.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: OSPF-MIB::ospfAdminStat.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m NET-SNMP-EXTEND-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' nsExtendNumEntries.0]  CMD EXITCODE[2] CMD RUNTIME[0.023s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: NET-SNMP-EXTEND-MIB::nsExtendNumEntries.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: NET-SNMP-EXTEND-MIB::nsExtendNumEntries.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m CPQSINFO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/hp 'udp':'roomalert.bluetowertech.local':'161' cpqSiProductName.0]  CMD EXITCODE[2] CMD RUNTIME[0.0562s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: CPQSINFO-MIB::cpqSiProductName.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: CPQSINFO-MIB::cpqSiProductName.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m MIB-Dell-10892 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'roomalert.bluetowertech.local':'161' systemManagementSoftwareName.0]  CMD EXITCODE[2] CMD RUNTIME[0.0515s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: MIB-Dell-10892::systemManagementSoftwareName.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: MIB-Dell-10892::systemManagementSoftwareName.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m ArrayManager-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'roomalert.bluetowertech.local':'161' arrayMgrSoftwareProduct.0]  CMD EXITCODE[2] CMD RUNTIME[0.0477s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: ArrayManager-MIB::arrayMgrSoftwareProduct.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: ArrayManager-MIB::arrayMgrSoftwareProduct.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m StorageManagement-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'roomalert.bluetowertech.local':'161' softwareVersion.0]  CMD EXITCODE[2] CMD RUNTIME[0.0581s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: StorageManagement-MIB::softwareVersion.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: StorageManagement-MIB::softwareVersion.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SUPERMICRO-HEALTH-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/supermicro 'udp':'roomalert.bluetowertech.local':'161' smHealthAllinoneStatus]  CMD EXITCODE[2] CMD RUNTIME[0.027s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: SUPERMICRO-HEALTH-MIB::smHealthAllinoneStatus ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: SUPERMICRO-HEALTH-MIB::smHealthAllinoneStatus CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SUPERMICRO-HEALTH-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/supermicro 'udp':'roomalert.bluetowertech.local':'161' smHealthMonitorName.1]  CMD EXITCODE[2] CMD RUNTIME[0.0462s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: SUPERMICRO-HEALTH-MIB::smHealthMonitorName.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: SUPERMICRO-HEALTH-MIB::smHealthMonitorName.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m SUPERMICRO-SD5-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/supermicro 'udp':'roomalert.bluetowertech.local':'161' sd5MIBVersion.1]  CMD EXITCODE[2] CMD RUNTIME[0.0292s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: SUPERMICRO-SD5-MIB::sd5MIBVersion.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: SUPERMICRO-SD5-MIB::sd5MIBVersion.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m PowerNet-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/apc 'udp':'roomalert.bluetowertech.local':'161' upsBasicIdentModel.0]  CMD EXITCODE[2] CMD RUNTIME[0.1071s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: PowerNet-MIB::upsBasicIdentModel.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: PowerNet-MIB::upsBasicIdentModel.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m LSI-MegaRAID-SAS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/lsi 'udp':'roomalert.bluetowertech.local':'161' mibVersion.0]  CMD EXITCODE[2] CMD RUNTIME[0.0316s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: LSI-MegaRAID-SAS-MIB::mibVersion.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: LSI-MegaRAID-SAS-MIB::mibVersion.0 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m LSI-MegaRAID-SAS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/lsi 'udp':'roomalert.bluetowertech.local':'161' mibVersion.1]  CMD EXITCODE[2] CMD RUNTIME[0.0261s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: LSI-MegaRAID-SAS-MIB::mibVersion.1 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: LSI-MegaRAID-SAS-MIB::mibVersion.1 CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m ARECA-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/areca 'udp':'roomalert.bluetowertech.local':'161' hwControllerBoardInstalled.0]  CMD EXITCODE[2] CMD RUNTIME[0.0275s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: ARECA-SNMP-MIB::hwControllerBoardInstalled.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] Store in cache OID: ARECA-SNMP-MIB::hwControllerBoardInstalled.0  o MIBs discovered   SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00041294s]  SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00034904s] JSON DECODE[Not string passed] JSON RAW[  > $str /opt/observium/includes/common.inc.php:5490  null ] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '122' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00030684s]    /opt/observium/includes/discovery/mibs.inc.php:313  array( [0] => string(12) "UCD-SNMP-MIB" [1] => string(18) "HOST-RESOURCES-MIB" [2] => string(10) "SNMPv2-MIB" [3] => string(18) "SNMP-FRAMEWORK-MIB" [4] => string(6) "IF-MIB" [5] => string(13) "ADSL-LINE-MIB" [6] => string(13) "EtherLike-MIB" [7] => string(10) "ENTITY-MIB" [8] => string(17) "ENTITY-SENSOR-MIB" [9] => string(12) "Q-BRIDGE-MIB" [10] => string(6) "IP-MIB" [11] => string(8) "IPV6-MIB" [12] => string(8) "LLDP-MIB" [13] => string(13) "CISCO-CDP-MIB" [14] => string(10) "PW-STD-MIB" [15] => string(15) "DISMAN-PING-MIB" [16] => string(8) "BGP4-MIB" )  o Duration  0.7718s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_vrf'] SQL RUNTIME[0.00501299s] ##### Module Start: vrf #####   SQL[SELECT COUNT(*) FROM `vrfs` WHERE `device_id` = '122' AND 1] SQL RUNTIME[0.00037503s]  SQL[SELECT COUNT(*) FROM `ports` WHERE `device_id` = '122' AND `ifVrf` IS NOT NULL AND 1] SQL RUNTIME[0.00034380s]   o Duration  0.0034s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_ports'] SQL RUNTIME[0.00030589s] ##### Module Start: ports #####   o Caching OIDs  ifDescr CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifDescr]  CMD EXITCODE[0] CMD RUNTIME[0.0289s] CMD EXITDELAY[10ms] STDOUT[ ifDescr.1 = Network ] SNMP STATUS[TRUE] ifAlias CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifAlias]  CMD EXITCODE[0] CMD RUNTIME[0.0232s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE] ifName CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifName]  CMD EXITCODE[0] CMD RUNTIME[0.0351s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE] ifType CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifType]  CMD EXITCODE[0] CMD RUNTIME[0.044s] CMD EXITDELAY[10ms] STDOUT[ ifType.1 = ethernetCsmacd ] SNMP STATUS[TRUE] ifOperStatus CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0347s] CMD EXITDELAY[10ms] STDOUT[ ifOperStatus.1 = up ] SNMP STATUS[TRUE]    /opt/observium/includes/discovery/ports.inc.php:44  array( [1] => array( [ifDescr] => string(7) "Network" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) )  o Caching DB   SQL[SELECT * FROM `ports` WHERE `device_id` = '122'] SQL RUNTIME[0.00075078s] 1 ports  o Discovering ports  . +---------+---------+--------+---------+----------------+-------------+---------+ | ifIndex | ifDescr | ifName | ifAlias | ifType | Oper Status | Ignored | +---------+---------+--------+---------+----------------+-------------+---------+ | 1 | Network | | ... | ethernetCsmacd | up | no | +---------+---------+--------+---------+----------------+-------------+---------+  o Duration  0.2325s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_ports-stack'] SQL RUNTIME[0.00078106s] ##### Module Start: ports-stack #####   SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '122'] SQL RUNTIME[0.00047112s]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ifStackStatus]  CMD EXITCODE[0] CMD RUNTIME[0.036s] STDOUT[ ] SNMP STATUS[TRUE]   o Duration  0.0393s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_vlans'] SQL RUNTIME[0.00051093s] ##### Module Start: vlans #####   SQL[SELECT * FROM `vlans` WHERE `device_id` = '122';] SQL RUNTIME[0.00114799s]  SQL[SELECT * FROM `ports_vlans` WHERE `device_id` = '122';] SQL RUNTIME[0.00088310s]  o Q-BRIDGE-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dot1qVlanStaticName]  CMD EXITCODE[0] CMD RUNTIME[0.0528s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dot1qVlanStaticRowStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0594s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dot1qVlanStaticEgressPorts]  CMD EXITCODE[0] CMD RUNTIME[0.0435s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dot1dBasePortIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0466s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dot1qPvid]  CMD EXITCODE[0] CMD RUNTIME[0.0547s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]   o Duration  0.302s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_oids'] SQL RUNTIME[0.00093818s] ##### Module Start: oids #####   SQL[SELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '122'] SQL RUNTIME[0.00052810s]  SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1'] SQL RUNTIME[0.00028491s]   o Duration  0.0029s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_ip-addresses'] SQL RUNTIME[0.00168705s] ##### Module Start: ip-addresses #####   SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00236201s] JSON DECODE[Not string passed] JSON RAW[   /opt/observium/includes/common.inc.php:5490  null ]  o IP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAdEntIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0308s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAdEntNetMask]  CMD EXITCODE[0] CMD RUNTIME[0.0404s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAddressIfIndex]  CMD EXITCODE[0] CMD RUNTIME[0.0661s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAddressType]  CMD EXITCODE[0] CMD RUNTIME[0.0398s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAddressPrefix]  CMD EXITCODE[0] CMD RUNTIME[0.0343s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipAddressOrigin]  CMD EXITCODE[0] CMD RUNTIME[0.0428s] STDOUT[ ] SNMP STATUS[TRUE]   o IPV6-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipv6AddrEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0241s] STDOUT[ ] SNMP STATUS[TRUE]   o LLDP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUsb -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' lldpLocManAddrTable]  CMD EXITCODE[0] CMD RUNTIME[0.0495s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `ipv4_addresses` WHERE `device_id` = '122'] SQL RUNTIME[0.00048518s]  SQL[SELECT * FROM `ipv6_addresses` WHERE `device_id` = '122'] SQL RUNTIME[0.00027180s]   o Duration  0.3698s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_processors'] SQL RUNTIME[0.00028300s] ##### Module Start: processors #####   o UCD-SNMP-MIB   SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '122' AND `processor_type` != 'ucd-old')] SQL RUNTIME[0.00027514s]  CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ssCpuIdle.0]  CMD EXITCODE[2] CMD RUNTIME[0.0226s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: UCD-SNMP-MIB::ssCpuIdle.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' hrDevice]  CMD EXITCODE[0] CMD RUNTIME[0.0265s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' hrProcessorLoad]  CMD EXITCODE[0] CMD RUNTIME[0.0283s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `processors` WHERE `device_id` = '122'] SQL RUNTIME[0.00048018s]   o Duration  0.1071s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_mempools'] SQL RUNTIME[0.00033689s] ##### Module Start: mempools #####   o UCD-SNMP-MIB   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]  CMD EXITCODE[2] CMD RUNTIME[0.0322s] CMD EXITDELAY[10ms] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memBuffer.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memCached.0 ] SNMP ERROR[#1000 - Failed response] SNMP ERROR[#1000 - Failed response] SNMP STATUS[FALSE]   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' hrStorageEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0179s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `mempools` WHERE `device_id` = '122'] SQL RUNTIME[0.00052500s]   o Duration  0.0665s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_inventory'] SQL RUNTIME[0.00043893s] ##### Module Start: inventory #####   o HOST-RESOURCES-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' hrDeviceEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0416s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' hrProcessorEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0448s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '122'] SQL RUNTIME[0.00054383s]   o ENTITY-MIB  ENTITY-MIB CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalEntry]  CMD EXITCODE[0] CMD RUNTIME[0.1417s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entAliasMappingIdentifier]  CMD EXITCODE[0] CMD RUNTIME[0.0184s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '122'] SQL RUNTIME[0.00042987s]   o Duration  0.2862s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_printersupplies'] SQL RUNTIME[0.00024199s] ##### Module Start: printersupplies #####   SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '122'] SQL RUNTIME[0.00021815s]   o Duration  0.0012s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_sensors'] SQL RUNTIME[0.00022006s] ##### Module Start: sensors #####   o ENTITY-SENSOR-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorValue]  CMD EXITCODE[0] CMD RUNTIME[0.017s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorType]  CMD EXITCODE[0] CMD RUNTIME[0.031s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorScale]  CMD EXITCODE[0] CMD RUNTIME[0.0261s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorPrecision]  CMD EXITCODE[0] CMD RUNTIME[0.0167s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorOperStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0161s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entPhySensorUnitsDisplay]  CMD EXITCODE[0] CMD RUNTIME[0.0162s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalDescr]  CMD EXITCODE[0] CMD RUNTIME[0.1693s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalName]  CMD EXITCODE[0] CMD RUNTIME[0.1088s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalClass]  CMD EXITCODE[0] CMD RUNTIME[0.0927s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalContainedIn]  CMD EXITCODE[0] CMD RUNTIME[0.0972s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' entPhysicalParentRelPos]  CMD EXITCODE[0] CMD RUNTIME[0.0923s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' entAliasMappingIdentifier]  CMD EXITCODE[0] CMD RUNTIME[0.0214s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00049496s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022388s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022197s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021887s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021505s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00028205s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022912s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022697s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021291s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021887s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021696s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021601s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022197s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021887s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021791s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021386s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'attenuation' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021911s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022411s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021696s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'concentration' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021386s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021720s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021791s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021505s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021911s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021696s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021815s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022411s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021887s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'distance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021696s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00021410s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00050712s]  SQL[SELECT * FROM `sensors` WHERE `device_id` = '122' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00043201s]  SQL[SELECT * FROM `status` WHERE `device_id` = '122' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00038314s]  SQL[SELECT * FROM `counters` WHERE `device_id` = '122' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'] SQL RUNTIME[0.00040793s]   o Duration  0.8393s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_storage'] SQL RUNTIME[0.00033402s] ##### Module Start: storage #####   o UCD-SNMP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' dskEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0122s] STDOUT[ ] SNMP STATUS[TRUE]   o HOST-RESOURCES-MIB   SQL[SELECT * FROM `storage` WHERE `device_id` = '122'] SQL RUNTIME[0.00044107s]   o Duration  0.0163s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_neighbours'] SQL RUNTIME[0.00035596s] ##### Module Start: neighbours #####   o LLDP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' lldpRemChassisIdSubtype]  CMD EXITCODE[0] CMD RUNTIME[0.0222s] STDOUT[ ] SNMP STATUS[TRUE]   o CISCO-CDP-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' cdpCache]  CMD EXITCODE[0] CMD RUNTIME[0.0855s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `neighbours` WHERE `device_id` = '122'] SQL RUNTIME[0.00060105s]   o Duration  0.1235s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_arp-table'] SQL RUNTIME[0.00036001s] ##### Module Start: arp-table #####   SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '122' GROUP BY `port_id`] SQL RUNTIME[0.00039101s]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipNetToPhysicalPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0291s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipv6NetToMediaPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0282s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' ipNetToMediaPhysAddress]  CMD EXITCODE[0] CMD RUNTIME[0.0155s] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M LEFT JOIN ports AS I ON M.port_id = I.port_id WHERE I.device_id = '122'] SQL RUNTIME[0.00066805s]   o Duration  0.1022s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_junose-atm-vp'] SQL RUNTIME[0.00035596s] ##### Module Start: junose-atm-vp #####    o Duration  0.0003s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_bgp-peers'] SQL RUNTIME[0.00033402s] ##### Module Start: bgp-peers #####   CMD[/usr/bin/snmpget -v1 -c *** -Pud -OQUv -m BGP4-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' bgpLocalAs.0]  CMD EXITCODE[2] CMD RUNTIME[0.0251s] STDOUT[ ] STDERR[ Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: BGP4-MIB::bgpLocalAs.0 ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] No BGP on host SQL[SELECT * FROM `bgpPeers` WHERE `device_id` = '122'] SQL RUNTIME[0.00056815s]   o Duration  0.029s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_mac-accounting'] SQL RUNTIME[0.00035596s] ##### Module Start: mac-accounting #####    o Duration  0.0003s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_sla'] SQL RUNTIME[0.00032687s] ##### Module Start: sla #####   o DISMAN-PING-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pingCtlEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0349s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `slas` WHERE `device_id` = '122'] SQL RUNTIME[0.00056481s]   o Duration  0.049s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_lsp'] SQL RUNTIME[0.00035906s] Module [lsp] disabled globally by config in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_pseudowires'] SQL RUNTIME[0.00032616s] ##### Module Start: pseudowires #####   SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '122'] SQL RUNTIME[0.00033593s]  o PW-STD-MIB   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwID]  CMD EXITCODE[0] CMD RUNTIME[0.0332s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwRowStatus]  CMD EXITCODE[0] CMD RUNTIME[0.0284s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwName]  CMD EXITCODE[0] CMD RUNTIME[0.0298s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwType]  CMD EXITCODE[0] CMD RUNTIME[0.0291s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwDescr]  CMD EXITCODE[0] CMD RUNTIME[0.0293s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwPsnType]  CMD EXITCODE[0] CMD RUNTIME[0.0331s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwPeerAddrType]  CMD EXITCODE[0] CMD RUNTIME[0.0315s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwPeerAddr]  CMD EXITCODE[0] CMD RUNTIME[0.0351s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwOutboundLabel]  CMD EXITCODE[0] CMD RUNTIME[0.0309s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwInboundLabel]  CMD EXITCODE[0] CMD RUNTIME[0.0214s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwRemoteIfString]  CMD EXITCODE[0] CMD RUNTIME[0.0225s] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-MPLS-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwMplsLocalLdpID]  CMD EXITCODE[0] CMD RUNTIME[0.0345s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m PW-MPLS-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' pwMplsPeerLdpID]  CMD EXITCODE[0] CMD RUNTIME[0.0365s] STDOUT[ ] SNMP STATUS[TRUE]   o Duration  0.5137s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_virtual-machines'] SQL RUNTIME[0.00055599s] ##### Module Start: virtual-machines #####    o Duration  0.0008s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_cisco-cbqos'] SQL RUNTIME[0.00035810s] ##### Module Start: cisco-cbqos #####   SQL[SELECT * FROM `ports_cbqos` WHERE `device_id` = '122'] SQL RUNTIME[0.00040007s]  CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m CISCO-CLASS-BASED-QOS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'roomalert.bluetowertech.local':'161' cbQosIfType]  CMD EXITCODE[0] CMD RUNTIME[0.1396s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE] QoS not configured.  o Duration  0.153s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_ucd-diskio'] SQL RUNTIME[0.00058413s] ##### Module Start: ucd-diskio #####   CMD[/usr/bin/snmpwalk -v1 -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'roomalert.bluetowertech.local':'161' diskIOEntry]  CMD EXITCODE[0] CMD RUNTIME[0.0262s] CMD EXITDELAY[10ms] STDOUT[ ] SNMP STATUS[TRUE]  SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '122'] SQL RUNTIME[0.00050688s]   o Duration  0.0396s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_wifi'] SQL RUNTIME[0.00034809s] Module [wifi] disabled for device type 'unknown'. in process [discovery]. SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_p2p-radios'] SQL RUNTIME[0.00028396s] ##### Module Start: p2p-radios #####    o Duration  0.0001s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_graphs'] SQL RUNTIME[0.00028610s] ##### Module Start: graphs #####    o Duration  0.0005s SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '122' AND `attrib_type` = 'discover_raid'] SQL RUNTIME[0.00113201s] Module [raid] disabled globally by config in process [discovery].  o Modules Disabled  lsp, wifi, raid  o Modules Enabled  os, mibs, vrf, ports, ports-stack, vlans, oids, ip-addresses, processors, mempools, inventory, printersupplies, sensors, storage,neighbours, arp-table, junose-atm-vp, bgp-peers, mac-accounting, sla, pseudowires, virtual-machines, cisco-cbqos,ucd-diskio, p2p-radios, graphs SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '122';] SQL RUNTIME[0.00303698s]  SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='unknown',`last_discovered_timetaken` ='4.4907',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:28:{s:6:\"system\";d:0.1508;s:2:\"os\";d:0.1849;s:4:\"ipmi\";d:0.0044;s:7:\"sensors\";d:0.0009;s:6:\"status\";d:0.0004;s:7:\"counter\";d:0.0004;s:10:\"processors\";d:0.0007;s:8:\"mempools\";d:0.0006;s:7:\"storage\";d:0.0017;s:8:\"netstats\";d:0.4191;s:7:\"ucd-mib\";d:0.1021;s:13:\"ipSystemStats\";d:0.0507;s:5:\"ports\";d:0.2644;s:9:\"bgp-peers\";d:0.0221;s:15:\"printersupplies\";d:0.0006;s:10:\"ucd-diskio\";d:0.0005;s:10:\"p2p-radios\";d:0.0009;s:4:\"ospf\";d:0.0003;s:3:\"sla\";d:0.0016;s:11:\"pseudowires\";d:0.0006;s:14:\"mac-accounting\";d:0.0007;s:12:\"loadbalancer\";d:0.0004;s:15:\"entity-physical\";d:0.0002;s:12:\"applications\";d:0.0008;s:9:\"fdb-table\";d:0.0674;s:6:\"graphs\";d:0.0765;s:4:\"oids\";d:0.0007;s:6:\"probes\";d:0.0006;}s:17:\"poller_ports_perf\";a:4:{s:6:\"IF-MIB\";d:0.0663909912109375;s:13:\"EtherLike-MIB\";d:0.02971792221069336;s:12:\"Q-BRIDGE-MIB\";d:0.0918588638305664;s:6:\"IP-MIB\";d:0.06299591064453125;}s:14:\"poller_history\";a:24:{i:1638208658;d:1.5146;i:1638208357;d:1.2417;i:1638208080;d:0.7928;i:1638207759;d:1.0426;i:1638207461;d:0.9367;i:1638207168;d:0.9633;i:1638206857;d:0.9841;i:1638206559;d:0.8529;i:1638206272;d:1.3002;i:1638205958;d:1.2873;i:1638205659;d:1.3294;i:1638205374;d:1.1329;i:1638205053;d:1.1574;i:1638204757;d:1.1831;i:1638204465;d:1.2946;i:1638204156;d:0.7548;i:1638203857;d:0.9166;i:1638203577;d:1.1481;i:1638203267;d:0.9736;i:1638202961;d:1.2478;i:1638202678;d:1.2153;i:1638202358;d:1.1858;i:1638202058;d:0.8565;i:1638201777;d:1.4749;}s:17:\"discovery_history\";a:9:{i:1638208830;d:4.4907;i:1638208696;d:3.4682;i:1638207199;d:3.2784;i:1638206802;d:3.1909;i:1638204989;d:3.1408;i:1638204928;d:3.6385;i:1638204919;d:3.5745;i:1638202308;d:3.6449;i:1638201602;d:5.1847;}s:18:\"discovery_mod_perf\";a:27:{s:2:\"os\";d:0.0002;s:4:\"mibs\";d:0.7718;s:3:\"vrf\";d:0.0034;s:5:\"ports\";d:0.2325;s:11:\"ports-stack\";d:0.0393;s:5:\"vlans\";d:0.302;s:11:\"ports_vlans\";N;s:4:\"oids\";d:0.0029;s:12:\"ip-addresses\";d:0.3698;s:10:\"processors\";d:0.1071;s:8:\"mempools\";d:0.0665;s:9:\"inventory\";d:0.2862;s:15:\"printersupplies\";d:0.0012;s:7:\"sensors\";d:0.8393;s:7:\"storage\";d:0.0163;s:10:\"neighbours\";d:0.1235;s:9:\"arp-table\";d:0.1022;s:13:\"junose-atm-vp\";d:0.0003;s:9:\"bgp-peers\";d:0.029;s:14:\"mac-accounting\";d:0.0003;s:3:\"sla\";d:0.049;s:11:\"pseudowires\";d:0.5137;s:16:\"virtual-machines\";d:0.0008;s:11:\"cisco-cbqos\";d:0.153;s:10:\"ucd-diskio\";d:0.0396;s:10:\"p2p-radios\";d:0.0001;s:6:\"graphs\";d:0.0005;}}' WHERE `device_id` = '122'] SQL RUNTIME[0.00379395s] ##### roomalert.bluetowertech.local [122] completed discovery modules at 2021-11-29 13:00:35 #####   o Discovery time  4.4907 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '20803' AND `process_name` = 'discovery.php' AND `device_id` = '122' AND `poller_id` = '0'] SQL RUNTIME[0.00288510s] ##### Finished discovery run at 2021-11-29 13:00:35 #####   SQL[SELECT * FROM `groups` ORDER BY `entity_type`] SQL RUNTIME[0.00024414s]  SQL[SELECT * FROM `groups_assoc`] SQL RUNTIME[0.00024390s]  SQL[SELECT `device_id` FROM `devices` WHERE ( `devices`.`device_id` IN ('100','101','105','104','103','26','75','76'))] SQL RUNTIME[0.00030112s]  SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '1'] SQL RUNTIME[0.00027895s] Group 'BTT Hyper-V Cluster Network Devices': 8 existing, 8 new entries (+0/-0). SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00019813s] Cached 0 alert rules. SQL[SELECT * FROM `alert_assoc`] SQL RUNTIME[0.00018406s] ./discovery.php: roomalert.bluetowertech.local - 1 devices discovered in 4.706 secs SQL[SELECT * FROM `observium_processes` WHERE `poller_id` = '0' AND `process_start` < '1638194430'] SQL RUNTIME[0.00022721s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.  o Devices Discovered  1  o Discovery Time  4.706 secs  o Memory usage  6MB (peak: 6MB)  o MySQL Usage  Cell[8/0.015s] Row[33/0.059s] Rows[69/0.083s] Column[2/0.002s] Update[1/0.005s] Insert[1/0.005s] Delete[2/0.005s]  o RRDTool Usage