DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0128s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/branches/stable Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 11451 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 11450 Last Changed Date: 2021-07-01 04:06:28 -0700 (Thu, 01 Jul 2021) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00050998s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00022602s] SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00019002s] DB mode(s) disabled: STRICT_TRANS_TABLES, ERROR_FOR_DIVISION_BY_ZERO CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0024s] STDOUT[ -07:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00032496s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00039911s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00031495s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 21.7.11450 https://www.observium.org SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00031495s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00024796s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00026608s] CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.014s] STDOUT[ Linux|3.10.0-1160.15.2.el7.x86_64|amd64|CentOS|7|kvm| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0033s] STDOUT[ Python 2.7.5 ] SQL[SELECT version();] SQL RUNTIME[0.00038099s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.006s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0068s] STDOUT[ RRDtool 1.7.1 Copyright by Tobias Oetiker ] CMD[/usr/sbin/fping -v 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0026s] STDOUT[ /usr/sbin/fping: Version 3.10 /usr/sbin/fping: comments to david@schweikert.ch ] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0031s] STDOUT[ ] CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0273s] STDOUT[ Apache/2.4.6 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00091100s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00079107s] ##### Software versions ##### o OS Linux 3.10.0-1160.15.2.el7.x86_64 [amd64] (CentOS 7) o Apache 2.4.6 o PHP 7.2.34 (OPcache: ENABLED) o Python 2.7.5 o MariaDB 10.4.13-MariaDB-log (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.2 o RRDtool 1.7.1 o Fping 3.10 (IPv4 and IPv6) ##### Memory Limit ##### o PHP 128MB ##### MariaDB mode ##### o MariaDB NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MariaDB utf8 ##### Timezones info ##### o Date Friday, 02-Jul-21 17:53:28 UTC o PHP +00:00 o MariaDB +00:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1625248408' AND `maint_end` > '1625248408'] SQL RUNTIME[0.00041986s] ##### Starting polling run at 2021-07-02 17:53:28 ##### SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'sb-hny-dsw-01.example.com' AND `poller_id` = '0' ORDER BY `device_id` ASC] SQL RUNTIME[0.00054717s] SQL[SELECT * FROM `devices` WHERE `device_id` = '47'] SQL RUNTIME[0.00068498s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '47'] SQL RUNTIME[0.00039792s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '47' AND `poller_id` = '0'] SQL RUNTIME[0.00030112s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('18045','poller.php','10884','0','php ./poller.php -d -m sensors -h sb-hny-dsw-01.example.com','1625248408','47')] SQL RUNTIME[0.00556493s] SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00054097s] Cached 26 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '47'] SQL RUNTIME[0.00038314s] ##### sb-hny-dsw-01.example.com [47] ##### o OS netonix-switch o Last poll duration 8.39 seconds o Last Polled 2021-07-02 17:51:14 o SNMP Version v2c CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0474s] STDOUT[ sysObjectID.0 = enterprises.46242 sysUpTime.0 = 38:4:59:41.74 ] SNMP STATUS[TRUE] o Device status Device is reachable by SNMP (47.41ms) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/status.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/status.rrd N:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.05] RRD_STATUS[TRUE] RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/ping_snmp.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/ping_snmp.rrd N:47.41] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.05] RRD_STATUS[TRUE] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '47'] SQL RUNTIME[0.00055909s] including: includes/polling/system.inc.php ##### Module Start: system ##### JSON DECODE[Not string passed] JSON DECODE[Not string passed] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '47' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00034118s] o SNMPv2-MIB CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0] CMD EXITCODE[0] CMD RUNTIME[0.0466s] STDOUT[ sysUpTime.0 = 38:4:59:41.79 sysLocation.0 = "48 6F 6E 65 79 " sysContact.0 = "61 64 6D 69 6E 40 73 68 61 73 74 61 62 65 61 6D 2E 63 6F 6D " sysName.0 = "73 62 2D 68 6E 79 2D 64 73 77 2D 30 31 " ] SNMP Hex string converted.. HEX: 48 6F 6E 65 79 STRING: Honey SNMP Hex string converted.. HEX: 61 64 6D 69 6E 40 73 68 61 73 74 61 62 65 61 6D 2E 63 6F 6D STRING: admin@shastabeam.com SNMP Hex string converted.. HEX: 73 62 2D 68 6E 79 2D 64 73 77 2D 30 31 STRING: sb-hny-dsw-01 SNMP STATUS[TRUE] Timeticks converted 38:4:59:41.79 -> 3301181 CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' sysDescr.0] CMD EXITCODE[0] CMD RUNTIME[0.0487s] STDOUT[ "4E 65 74 6F 6E 69 78 20 57 53 2D 31 32 2D 32 35 30 2D 41 43 " ] SNMP Hex string converted.. HEX: 4E 65 74 6F 6E 69 78 20 57 53 2D 31 32 2D 32 35 30 2D 41 43 STRING: Netonix WS-12-250-AC SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' sysObjectID.0] CMD EXITCODE[0] CMD RUNTIME[0.0464s] STDOUT[ .1.3.6.1.4.1.46242 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' snmpEngineID.0] CMD EXITCODE[0] CMD RUNTIME[0.0484s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '47' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'SNMP-FRAMEWORK-MIB' AND `oid` = 'snmpEngineID.0';] SQL RUNTIME[0.00055099s] SQL[UPDATE `snmp_errors` set `error_count` ='342811',`updated` ='1625248409' WHERE `error_id` = '902'] SQL RUNTIME[0.00579596s] CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' hrSystemUptime.0] CMD EXITCODE[0] CMD RUNTIME[0.0484s] STDOUT[ 38:5:02:27.02 ] SNMP STATUS[TRUE] Timeticks converted 38:5:02:27.02 -> 3301347 CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' snmpEngineTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0459s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '47' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'SNMP-FRAMEWORK-MIB' AND `oid` = 'snmpEngineTime.0';] SQL RUNTIME[0.00055695s] SQL[UPDATE `snmp_errors` set `error_count` ='342810',`updated` ='1625248409' WHERE `error_id` = '903'] SQL RUNTIME[0.00592089s] Using SNMP Agent hrSystemUptime (3301347 sec. => 38 days, 5h 2m 27s) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/uptime.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/uptime.rrd N:3301347] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.36] RRD_STATUS[TRUE] o Uptime 38 days, 5h 2m 27s o Last reboot 05-25-2021 12:50:05 /opt/observium/includes/polling/system.inc.php:227 array( [use] => string(14) "hrSystemUptime" [sysUpTime] => int(3301181) [hrSystemUptime] => int(3301347) [uptime] => int(3301347) [formatted] => string(18) "38 days, 5h 2m 27s" [message] => string(31) "Using SNMP Agent hrSystemUptime" [previous] => string(7) "3301204" [diff] => int(-143) [last_rebooted] => string(10) "1621947005" [rebooted] => int(0) ) CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3] CMD EXITCODE[0] CMD RUNTIME[0.0479s] STDOUT[ .1.3.6.1.4.1.2021.10.1.5.1 = 2 .1.3.6.1.4.1.2021.10.1.5.2 = 13 .1.3.6.1.4.1.2021.10.1.5.3 = 16 ] SNMP STATUS[TRUE] RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/la.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/la.rrd N:2:13:16] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.41] RRD_STATUS[TRUE] o Load average 0.02, 0.13, 0.16 sysLocation rewritten from 'Honey' to '8700 Honey Lane, Millville, CA, USA' by $config['location']['map']. o sysObjectID .1.3.6.1.4.1.46242 o snmpEngineID o sysDescr Netonix WS-12-250-AC o sysName sb-hny-dsw-01 o Location 8700 Honey Lane, Millville, CA, USA SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '47'] SQL RUNTIME[0.00053406s] o Module time 0.3597s including: includes/polling/os.inc.php ##### Module Start: os ##### Added OS param from sysDescr pattern: 'hardware' = 'WS-12-250-AC' (/Netonix (?\S+)/) CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -Ih -OQUvx --hexOutputLength=0 -m NETONIX-SWITCH-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/netonix 'udp':'sb-hny-dsw-01.example.com':'161' firmwareVersion.0] CMD EXITCODE[0] CMD RUNTIME[0.0463s] STDOUT[ "31 2E 35 2E 32 72 63 34 " ] SNMP Hex string converted.. HEX: 31 2E 35 2E 32 72 63 34 STRING: 1.5.2rc4 SNMP STATUS[TRUE] Added Device param from SNMP definition by [NETONIX-SWITCH-MIB::firmwareVersion.0]: 'version' = '1.5.2rc4' o OS Poller Generic o Type Network o Vendor Netonix o Hardware WS-12-250-AC o Version 1.5.2rc4 o Features o Serial o Asset o Module time 0.0492s including: includes/polling/sensors.inc.php ##### Module Start: sensors ##### SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '47' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','power','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','attenuation','snr','dust','concentration','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','distance','illuminance','wavelength','gauge')] SQL RUNTIME[0.00075817s] SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '47' AND `entity_type` = 'sensor'] SQL RUNTIME[0.00031495s] SQL[SELECT DISTINCT `sensor_oid` FROM `sensors` WHERE `device_id` = '47' AND `sensor_deleted` = '0' AND `poller_type` = 'snmp'] SQL RUNTIME[0.00033402s] CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' .1.3.6.1.2.1.105.1.3.1.1.4.8 .1.3.6.1.2.1.105.1.3.1.1.4.9 .1.3.6.1.2.1.105.1.3.1.1.4.12 .1.3.6.1.4.1.46242.2.1.2.1 .1.3.6.1.4.1.46242.3.1.3.1 .1.3.6.1.4.1.46242.3.1.3.2 .1.3.6.1.4.1.46242.3.1.3.3 .1.3.6.1.4.1.46242.4.1.3.1 .1.3.6.1.4.1.46242.4.1.3.2 .1.3.6.1.4.1.46242.4.1.3.3 .1.3.6.1.4.1.46242.6.0.0] CMD EXITCODE[0] CMD RUNTIME[0.1966s] STDOUT[ .1.3.6.1.2.1.105.1.3.1.1.4.8 = 9 .1.3.6.1.2.1.105.1.3.1.1.4.9 = 4 .1.3.6.1.2.1.105.1.3.1.1.4.12 = 0 .1.3.6.1.4.1.46242.2.1.2.1 = 8820 .1.3.6.1.4.1.46242.3.1.3.1 = 55 .1.3.6.1.4.1.46242.3.1.3.2 = 67 .1.3.6.1.4.1.46242.3.1.3.3 = 67 .1.3.6.1.4.1.46242.4.1.3.1 = 4860 .1.3.6.1.4.1.46242.4.1.3.2 = 2440 .1.3.6.1.4.1.46242.4.1.3.3 = 330 .1.3.6.1.4.1.46242.6.0.0 = No Such Instance currently exists at this OID ] SNMP STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '47' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00090003s] Checking (snmp) power Port 12 PoE Power /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "115" [sensor_deleted] => string(1) "0" [sensor_class] => string(5) "power" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(29) ".1.3.6.1.2.1.105.1.3.1.1.4.12" [sensor_mib] => string(0) "" [sensor_object] => string(0) "" [sensor_index] => string(30) "pethMainPseConsumptionPower.12" [sensor_type] => string(18) "power-ethernet-mib" [sensor_descr] => string(17) "Port 12 PoE Power" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(2) "12" [measured_class] => string(4) "port" [measured_entity] => string(3) "719" [measured_entity_label] => null [entPhysicalIndex] => string(2) "12" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248266" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(0) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.12.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.12.rrd N:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.67] RRD_STATUS[TRUE] Checking (snmp) power Port 8 PoE Power /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "196" [sensor_deleted] => string(1) "0" [sensor_class] => string(5) "power" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(28) ".1.3.6.1.2.1.105.1.3.1.1.4.8" [sensor_mib] => string(0) "" [sensor_object] => string(0) "" [sensor_index] => string(29) "pethMainPseConsumptionPower.8" [sensor_type] => string(18) "power-ethernet-mib" [sensor_descr] => string(16) "Port 8 PoE Power" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(1) "9" [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(1) "8" [measured_class] => string(4) "port" [measured_entity] => string(3) "715" [measured_entity_label] => null [entPhysicalIndex] => string(1) "8" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "10.0000000000000000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1625248266" [sensor_last_change] => string(10) "1625247379" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(9) ) SQL[SELECT * FROM `ports` WHERE `ports`.`port_id` = '715'] SQL RUNTIME[0.00054502s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '715'] SQL RUNTIME[0.00034499s] SQL[SELECT * FROM `devices` WHERE `device_id` = '47'] SQL RUNTIME[0.00046301s] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '47'] SQL RUNTIME[0.00033998s] RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.8.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.8.rrd N:9] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.67] RRD_STATUS[TRUE] Checking (snmp) power Port 9 PoE Power /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "114" [sensor_deleted] => string(1) "0" [sensor_class] => string(5) "power" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(28) ".1.3.6.1.2.1.105.1.3.1.1.4.9" [sensor_mib] => string(0) "" [sensor_object] => string(0) "" [sensor_index] => string(29) "pethMainPseConsumptionPower.9" [sensor_type] => string(18) "power-ethernet-mib" [sensor_descr] => string(16) "Port 9 PoE Power" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(3) "4.5" [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => string(1) "9" [measured_class] => string(4) "port" [measured_entity] => string(3) "716" [measured_entity_label] => null [entPhysicalIndex] => string(1) "9" [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "8.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248266" [sensor_last_change] => string(10) "1625247975" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(4) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.9.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-power-ethernet-mib-pethMainPseConsumptionPower.9.rrd N:4] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.67] RRD_STATUS[TRUE] Checking (snmp) power Total Power Consumption /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "116" [sensor_deleted] => string(1) "0" [sensor_class] => string(5) "power" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(24) ".1.3.6.1.4.1.46242.6.0.0" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(21) "totalPowerConsumption" [sensor_index] => string(1) "0" [sensor_type] => string(40) "NETONIX-SWITCH-MIB-totalPowerConsumption" [sensor_descr] => string(23) "Total Power Consumption" [sensor_unit] => null [sensor_multiplier] => string(3) "0.1" [sensor_limit] => string(4) "30.3" [sensor_limit_warn] => null [sensor_limit_low] => null [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "0.0000000000000000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1614423668" ) CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'sb-hny-dsw-01.example.com':'161' .1.3.6.1.4.1.46242.6.0.0] CMD EXITCODE[0] CMD RUNTIME[0.0465s] STDOUT[ No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '47' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'SNMPv2-MIB' AND `oid` = '.1.3.6.1.4.1.46242.6.0.0';] SQL RUNTIME[0.00053310s] SQL[UPDATE `snmp_errors` set `error_count` ='260565',`updated` ='1625248409' WHERE `error_id` = '3785'] SQL RUNTIME[0.00660086s] /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => string(0) "" ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-NETONIX-SWITCH-MIB-totalPowerConsumption-0.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-power-NETONIX-SWITCH-MIB-totalPowerConsumption-0.rrd N:] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.73] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '47' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00061202s] Checking (snmp) fanspeed Fan /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "117" [sensor_deleted] => string(1) "0" [sensor_class] => string(8) "fanspeed" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.2.1.2.1" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(8) "fanSpeed" [sensor_index] => string(1) "1" [sensor_type] => string(27) "NETONIX-SWITCH-MIB-fanSpeed" [sensor_descr] => string(3) "Fan" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(5) "10000" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "1" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(21) "8850.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1625246764" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(8820) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-fanspeed-NETONIX-SWITCH-MIB-fanSpeed-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-fanspeed-NETONIX-SWITCH-MIB-fanSpeed-1.rrd N:8820] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.73] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '47' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00058603s] Checking (snmp) temperature Board Temp /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "118" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.3.1.3.1" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(4) "temp" [sensor_index] => string(1) "1" [sensor_type] => string(23) "NETONIX-SWITCH-MIB-temp" [sensor_descr] => string(10) "Board Temp" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(4) "86.4" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "55.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1625081768" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(55) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-1.rrd N:55] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] Checking (snmp) temperature CPU Temp /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "119" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.3.1.3.2" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(4) "temp" [sensor_index] => string(1) "2" [sensor_type] => string(23) "NETONIX-SWITCH-MIB-temp" [sensor_descr] => string(8) "CPU Temp" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(5) "105.6" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "67.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(67) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-2.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-2.rrd N:67] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] Checking (snmp) temperature PHY Temp /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "120" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.3.1.3.3" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(4) "temp" [sensor_index] => string(1) "3" [sensor_type] => string(23) "NETONIX-SWITCH-MIB-temp" [sensor_descr] => string(8) "PHY Temp" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(3) "104" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "66.0000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(67) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-3.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-temperature-NETONIX-SWITCH-MIB-temp-3.rrd N:67] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '47' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00066495s] Checking (snmp) voltage Board 48V /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "121" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.4.1.3.1" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(7) "voltage" [sensor_index] => string(1) "1" [sensor_type] => string(26) "NETONIX-SWITCH-MIB-voltage" [sensor_descr] => string(9) "Board 48V" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => string(6) "55.775" [sensor_limit_warn] => null [sensor_limit_low] => string(6) "41.225" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "48.6000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(4860) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-1.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-1.rrd N:48.6] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] Checking (snmp) voltage Board 24V /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "122" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.4.1.3.2" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(7) "voltage" [sensor_index] => string(1) "2" [sensor_type] => string(26) "NETONIX-SWITCH-MIB-voltage" [sensor_descr] => string(9) "Board 24V" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => string(5) "28.06" [sensor_limit_warn] => null [sensor_limit_low] => string(5) "20.74" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(19) "24.3000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(2440) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-2.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-2.rrd N:24.4] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] Checking (snmp) voltage Board 3V /opt/observium/includes/entities/sensor.inc.php:703 array( [sensor_id] => string(3) "123" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(2) "47" [poller_type] => string(4) "snmp" [sensor_oid] => string(26) ".1.3.6.1.4.1.46242.4.1.3.3" [sensor_mib] => string(18) "NETONIX-SWITCH-MIB" [sensor_object] => string(7) "voltage" [sensor_index] => string(1) "3" [sensor_type] => string(26) "NETONIX-SWITCH-MIB-voltage" [sensor_descr] => string(8) "Board 3V" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => string(5) "3.795" [sensor_limit_warn] => null [sensor_limit_low] => string(5) "2.805" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [measured_entity_label] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(18) "3.3000000000000000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1625248267" [sensor_last_change] => string(10) "1522092029" ) value taken from oid_cache /opt/observium/includes/entities/sensor.inc.php:778 array( [sensor_value] => int(330) ) RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-3.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/sensor-voltage-NETONIX-SWITCH-MIB-voltage-3.rrd N:3.3] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.74] RRD_STATUS[TRUE] MultiUpdate sensors DB. SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`) VALUES ('115','0','ok','','1522092029','1625248409'),('196','9','alert','Sensor critical thresholds exceeded.','1625247379','1625248409'),('114','4','ok','','1625247975','1625248409'),('116','','alert','Sensor critical thresholds exceeded.','1614423668','1625248409'),('117','8820','ok','','1625246764','1625248409'),('118','55','ok','','1625081768','1625248409'),('119','67','ok','','1522092029','1625248409'),('120','67','ok','','1522092029','1625248409'),('121','48.6','ok','','1522092029','1625248409'),('122','24.4','ok','','1522092029','1625248409'),('123','3.3','ok','','1522092029','1625248409') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)] SQL RUNTIME[0.00563598s] SQL WARNINGS[ 1364: Field 'sensor_class' doesn't have a default value 1364: Field 'sensor_oid' doesn't have a default value 1366: Incorrect double value: '' for column `observium`.`sensors`.`sensor_value` at row 4 ] +-------------------------+-------------+------------------------------------------+--------+----------+-------+---------------------+ | Descr | Class | Type | Origin | Value | Event | Last Changed | +-------------------------+-------------+------------------------------------------+--------+----------+-------+---------------------+ | Port 12 PoE Power | power | power-ethernet-mib | snmp | 0W | ok | 03-26-2018 19:20:29 | | Port 8 PoE Power | power | power-ethernet-mib | snmp | 9W | alert | 07-02-2021 17:36:19 | | Port 9 PoE Power | power | power-ethernet-mib | snmp | 4W | ok | 07-02-2021 17:46:15 | | Total Power Consumption | power | NETONIX-SWITCH-MIB-totalPowerConsumption | snmp | W | alert | 02-27-2021 11:01:08 | | Fan | fanspeed | NETONIX-SWITCH-MIB-fanSpeed | snmp | 8820RPM | ok | 07-02-2021 17:26:04 | | Board Temp | temperature | NETONIX-SWITCH-MIB-temp | snmp | 55°C | ok | 06-30-2021 19:36:08 | | CPU Temp | temperature | NETONIX-SWITCH-MIB-temp | snmp | 67°C | ok | 03-26-2018 19:20:29 | | PHY Temp | temperature | NETONIX-SWITCH-MIB-temp | snmp | 67°C | ok | 03-26-2018 19:20:29 | | Board 48V | voltage | NETONIX-SWITCH-MIB-voltage | snmp | 48.6V | ok | 03-26-2018 19:20:29 | | Board 24V | voltage | NETONIX-SWITCH-MIB-voltage | snmp | 24.4V | ok | 03-26-2018 19:20:29 | | Board 3V | voltage | NETONIX-SWITCH-MIB-voltage | snmp | 3.3V | ok | 03-26-2018 19:20:29 | +-------------------------+-------------+------------------------------------------+--------+----------+-------+---------------------+ o Module time 0.3022s ##### sb-hny-dsw-01.example.com [47] completed poller modules at 2021-07-02 17:53:29 ##### o Graphs [checked] availability, ping_snmp, uptime, la, power, fanspeed, temperature, voltage o Poller time 0.7722 seconds Updating sb-hny-dsw-01.example.com - /opt/observium/includes/polling/functions.inc.php:464 array( [uptime] => int(3301347) [last_polled] => array( [0] => string(5) "NOW()" ) [last_polled_timetaken] => double(0.7722) ) SQL[UPDATE `devices` set `uptime` ='3301347',`last_polled` =NOW(),`last_polled_timetaken` ='0.7722' WHERE `device_id` = '47'] SQL RUNTIME[0.00621915s] o Updated Data uptime, last_polled, last_polled_timetaken SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_status\":\"1\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1625248409',`last_ok` ='1625248409' WHERE `alert_table_id` = '40'] SQL RUNTIME[0.00529385s] RRD /opt/observium/rrd/sb-hny-dsw-01.example.com/alert-40.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/sb-hny-dsw-01.example.com/alert-40.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.78] RRD_STATUS[TRUE] SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '18045' AND `process_name` = 'poller.php' AND `device_id` = '47' AND `poller_id` = '0'] SQL RUNTIME[0.00541210s] poller.php: sb-hny-dsw-01.example.com - 1 devices polled in 0.869 secs ##### Completed polling run at 2021-07-02 17:53:29 ##### NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Polled 1 o Poller Time 0.869 secs o Memory usage 6MB (peak: 6MB) o MySQL Usage Insert[1/0.006s] Update[6/0.036s] Delete[1/0.006s] Cell[4/0.002s] Row[12/0.007s] Rows[19/0.011s] Col[3/0.002s] Connect[1/0.003s](0.073s 8.445%) o RRDTool Usage update[16/0.018s] (0.018s 2.021%) o SNMP Usage snmpget[11/0.669s] errors[/0s] (0.669s 76.999%)