:/opt/observium # ./discovery.php -h slx9140 -d
DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0329s]
CMD EXITDELAY[10ms]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: http://svn.observium.org/svn/observium/trunk
Relative URL: ^/observium/trunk
Repository Root: http://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 10661
Node Kind: directory
Schedule: normal
Last Changed Author: mike
Last Changed Rev: 10661
Last Changed Date: 2020-09-07 13:57:16 +0200 (Mon, 07 Sep 2020)

]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00009394s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00020885s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00017095s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00008988s]

CMD[/bin/hostname -f]

CMD EXITCODE[0]
CMD RUNTIME[0.0032s]
STDOUT[
nettools.****.**
]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                          Observium Professional 20.9.10661
                                  https://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.0725s]
STDOUT[
Linux|4.9.0-4-amd64|amd64|Debian|9.2|bochs|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0027s]
STDOUT[
Python 2.7.13
]

SQL[SELECT version();]
SQL RUNTIME[0.00017715s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0112s]
STDOUT[
NET-SNMP version: 5.7.3
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0127s]
STDOUT[
RRDtool 1.6.0  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/rrdcached -h | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0098s]
STDOUT[
RRDCacheD 1.6.0
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0013s]
STDOUT[
/usr/bin/fping: Version 3.15
/usr/bin/fping: comments to david@schweikert.ch
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0315s]
STDOUT[
Apache/2.4.25
]

CMD[date "+%:z"]

CMD EXITCODE[0]
CMD RUNTIME[0.0016s]
CMD EXITDELAY[10ms]
STDOUT[
+02:00
]

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00022602s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00014615s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00078893s]

#####  Software versions  #####

 o OS                   Linux 4.9.0-4-amd64 [amd64] (Debian 9.2)
 o Apache               2.4.25
 o PHP                  7.0.19-1 (OPcache: ENABLED)
 o Python               2.7.13
 o MariaDB              10.1.26-MariaDB-0+deb9u1 (extension: mysqli 5.0.12-dev)
 o SNMP                 NET-SNMP 5.7.3
 o RRDtool              1.6.0 (rrdcached 1.6.0: unix:/var/run/rrdcached.sock)
 o Fping                3.15 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  Unlimited

#####  MariaDB mode  #####

 o MariaDB              NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MariaDB              utf8

#####  Timezones info  #####

 o Date                 Monday, 21-Sep-20 13:15:51 CEST
 o PHP                  +02:00
 o MariaDB              +02:00


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00008798s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00007296s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';]
SQL RUNTIME[0.00007010s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';]
SQL RUNTIME[0.00006890s]
There is a newer revision of Observium available!
Version 20.9.10707 (21st September 2020) is 46 revisions ahead.

#####  Starting discovery run at 2020-09-21 13:15:51  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'slx9140' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00052786s]

CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' sysObjectID.0 sysUpTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0196s]
STDOUT[
sysObjectID.0 = enterprises.1588.3.3.1.3001
sysUpTime.0 = 230:19:51:42.00
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716']
SQL RUNTIME[0.00014186s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '716']
SQL RUNTIME[0.00025511s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`)  VALUES ('10362','discovery.php','22424','0','php ./discovery.php -h slx9140 -d','1600686951','716')]
SQL RUNTIME[0.00070119s]
#####  slx9140 [716]  #####

 o OS Type              slx
 o SNMP Version         v2c
 o Last discovery       2020-09-21 05:57:50
 o Last duration        24.47 seconds

#####  Module Start: os  #####


CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0096s]
STDOUT[
Top Of Rack, SLX Operating System Version 18s.1.01c.
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0102s]
STDOUT[
.1.3.6.1.4.1.1588.3.3.1.3001
]
SNMP STATUS[TRUE]
+-------------+------------------------------------------------------+
| OID         |                                                      |
+-------------+------------------------------------------------------+
| sysDescr    | Top Of Rack, SLX Operating System Version 18s.1.01c. |
| sysObjectID | .1.3.6.1.4.1.1588.3.3.1.3001                         |
+-------------+------------------------------------------------------+

 o Re-Detect OS matched (slx: Extreme SLX OS): 
+-------------+-----------------------+------------------------------------------------------+
| OID         | Matched definition    |                                                      |
+-------------+-----------------------+------------------------------------------------------+
| sysObjectID | .1.3.6.1.4.1.1588.3.3 | .1.3.6.1.4.1.1588.3.3.1.3001                         |
| sysDescr    | /\ SLX\ /             | Top Of Rack, SLX Operating System Version 18s.1.01c. |
+-------------+-----------------------+------------------------------------------------------+


 o Duration             0.0536s

#####  Module Start: mibs  #####


CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']

CMD EXITCODE[0]
CMD RUNTIME[0.0049s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2'

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' .1.3.6.1.2.1.1.9.1.2]

CMD EXITCODE[0]
CMD RUNTIME[0.0234s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2 = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' sysORDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0217s]
STDOUT[
sysORDescr = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ospfAdminStat.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0157s]
STDOUT[
disabled
]
SNMP STATUS[TRUE]
Store in cache OID: OSPF-MIB::ospfAdminStat.0

CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m MPLS-L3VPN-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' mplsL3VpnConfiguredVrfs.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0105s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
Store in cache OID: MPLS-L3VPN-STD-MIB::mplsL3VpnConfiguredVrfs.0
 o MIBs discovered      <empty>
SQL[DELETE FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00030208s]

 o Duration             0.088s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_ports']
SQL RUNTIME[0.00027895s]
#####  Module Start: ports  #####

 o Caching OIDs         
SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00044107s]

SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '716' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00018787s]
ifDescr 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.1147s]
STDOUT[
ifDescr.201335168 = Ethernet 0/1
ifDescr.201343360 = Ethernet 0/2
ifDescr.201351552 = Ethernet 0/3
ifDescr.201359744 = Ethernet 0/4
ifDescr.201367936 = Ethernet 0/5
ifDescr.201376128 = Ethernet 0/6
ifDescr.201384320 = Ethernet 0/7
ifDescr.201392512 = Ethernet 0/8
ifDescr.201400704 = Ethernet 0/9
ifDescr.201408896 = Ethernet 0/10
ifDescr.201417088 = Ethernet 0/11
ifDescr.201425280 = Ethernet 0/12
ifDescr.201433472 = Ethernet 0/13
ifDescr.201441664 = Ethernet 0/14
ifDescr.201449856 = Ethernet 0/15
ifDescr.201458048 = Ethernet 0/16
ifDescr.201466240 = Ethernet 0/17
ifDescr.201474432 = Ethernet 0/18
ifDescr.201482624 = Ethernet 0/19
ifDescr.201490816 = Ethernet 0/20
ifDescr.201499008 = Ethernet 0/21
ifDescr.201507200 = Ethernet 0/22
ifDescr.201515392 = Ethernet 0/23
ifDescr.201523584 = Ethernet 0/24
ifDescr.201531776 = Ethernet 0/25
ifDescr.201539968 = Ethernet 0/26
ifDescr.201548160 = Ethernet 0/27
ifDescr.201556352 = Ethernet 0/28
ifDescr.201564544 = Ethernet 0/29
ifDescr.201572736 = Ethernet 0/30
ifDescr.201580928 = Ethernet 0/31
ifDescr.201589120 = Ethernet 0/32
ifDescr.201597312 = Ethernet 0/33
ifDescr.201605504 = Ethernet 0/34
ifDescr.201613696 = Ethernet 0/35
ifDescr.201621888 = Ethernet 0/36
ifDescr.201630080 = Ethernet 0/37
ifDescr.201638272 = Ethernet 0/38
ifDescr.201646464 = Ethernet 0/39
ifDescr.201654656 = Ethernet 0/40
ifDescr.201662848 = Ethernet 0/41
ifDescr.201671040 = Ethernet 0/42
ifDescr.201679232 = Ethernet 0/43
ifDescr.201687424 = Ethernet 0/44
ifDescr.201695616 = Ethernet 0/45
ifDescr.201703808 = Ethernet 0/46
ifDescr.201712000 = Ethernet 0/47
ifDescr.201720192 = Ethernet 0/48
ifDescr.201728256 = Ethernet 0/49
ifDescr.201736448 = Ethernet 0/50
ifDescr.201744640 = Ethernet 0/51
ifDescr.201752832 = Ethernet 0/52
ifDescr.201761024 = Ethernet 0/53
ifDescr.201769216 = Ethernet 0/54
ifDescr.201924736 = Ethernet 0/73
ifDescr.671088650 = Port-channel 10
ifDescr.671088660 = Port-channel 20
ifDescr.805306369 = eth0
ifDescr.805306370 = eth1
ifDescr.1207959553 = Ve 1
]
SNMP STATUS[TRUE]
ifAlias 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifAlias]

CMD EXITCODE[0]
CMD RUNTIME[0.7105s]
STDOUT[
ifAlias.201335168 = 
ifAlias.201343360 = 
ifAlias.201351552 = 
ifAlias.201359744 = 
ifAlias.201367936 = 
ifAlias.201376128 = 
ifAlias.201384320 = 
ifAlias.201392512 = 
ifAlias.201400704 = 
ifAlias.201408896 = 
ifAlias.201417088 = 
ifAlias.201425280 = 
ifAlias.201433472 = 
ifAlias.201441664 = 
ifAlias.201449856 = 
ifAlias.201458048 = 
ifAlias.201466240 = 
ifAlias.201474432 = 
ifAlias.201482624 = 
ifAlias.201490816 = 
ifAlias.201499008 = 
ifAlias.201507200 = 
ifAlias.201515392 = 
ifAlias.201523584 = 
ifAlias.201531776 = 
ifAlias.201539968 = 
ifAlias.201548160 = 
ifAlias.201556352 = 
ifAlias.201564544 = 
ifAlias.201572736 = 
ifAlias.201580928 = 
ifAlias.201589120 = 
ifAlias.201597312 = 
ifAlias.201605504 = 
ifAlias.201613696 = 
ifAlias.201621888 = 
ifAlias.201630080 = 
ifAlias.201638272 = 
ifAlias.201646464 = 
ifAlias.201654656 = 
ifAlias.201662848 = 
ifAlias.201671040 = 
ifAlias.201679232 = 
ifAlias.201687424 = 
ifAlias.201695616 = 
ifAlias.201703808 = 
ifAlias.201712000 = 
ifAlias.201720192 = 
ifAlias.201728256 = LAG_nexus1-2
ifAlias.201736448 = LAG_nexus1-2
ifAlias.201744640 = LAG_eswrdc1-2
ifAlias.201752832 = LAG_eswrdc1-2
ifAlias.201761024 = 
ifAlias.201769216 = 
ifAlias.201924736 = 
ifAlias.671088650 = LAG_nexus1-2
ifAlias.671088660 = LAG_eswrdc1-2
ifAlias.805306369 = 
ifAlias.805306370 = 
ifAlias.1207959553 = 
]
SNMP STATUS[TRUE]
ifName 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifName]

CMD EXITCODE[0]
CMD RUNTIME[0.1041s]
CMD EXITDELAY[10ms]
STDOUT[
ifName.201335168 = Ethernet 0/1
ifName.201343360 = Ethernet 0/2
ifName.201351552 = Ethernet 0/3
ifName.201359744 = Ethernet 0/4
ifName.201367936 = Ethernet 0/5
ifName.201376128 = Ethernet 0/6
ifName.201384320 = Ethernet 0/7
ifName.201392512 = Ethernet 0/8
ifName.201400704 = Ethernet 0/9
ifName.201408896 = Ethernet 0/10
ifName.201417088 = Ethernet 0/11
ifName.201425280 = Ethernet 0/12
ifName.201433472 = Ethernet 0/13
ifName.201441664 = Ethernet 0/14
ifName.201449856 = Ethernet 0/15
ifName.201458048 = Ethernet 0/16
ifName.201466240 = Ethernet 0/17
ifName.201474432 = Ethernet 0/18
ifName.201482624 = Ethernet 0/19
ifName.201490816 = Ethernet 0/20
ifName.201499008 = Ethernet 0/21
ifName.201507200 = Ethernet 0/22
ifName.201515392 = Ethernet 0/23
ifName.201523584 = Ethernet 0/24
ifName.201531776 = Ethernet 0/25
ifName.201539968 = Ethernet 0/26
ifName.201548160 = Ethernet 0/27
ifName.201556352 = Ethernet 0/28
ifName.201564544 = Ethernet 0/29
ifName.201572736 = Ethernet 0/30
ifName.201580928 = Ethernet 0/31
ifName.201589120 = Ethernet 0/32
ifName.201597312 = Ethernet 0/33
ifName.201605504 = Ethernet 0/34
ifName.201613696 = Ethernet 0/35
ifName.201621888 = Ethernet 0/36
ifName.201630080 = Ethernet 0/37
ifName.201638272 = Ethernet 0/38
ifName.201646464 = Ethernet 0/39
ifName.201654656 = Ethernet 0/40
ifName.201662848 = Ethernet 0/41
ifName.201671040 = Ethernet 0/42
ifName.201679232 = Ethernet 0/43
ifName.201687424 = Ethernet 0/44
ifName.201695616 = Ethernet 0/45
ifName.201703808 = Ethernet 0/46
ifName.201712000 = Ethernet 0/47
ifName.201720192 = Ethernet 0/48
ifName.201728256 = Ethernet 0/49
ifName.201736448 = Ethernet 0/50
ifName.201744640 = Ethernet 0/51
ifName.201752832 = Ethernet 0/52
ifName.201761024 = Ethernet 0/53
ifName.201769216 = Ethernet 0/54
ifName.201924736 = Ethernet 0/73
ifName.671088650 = Port-channel 10
ifName.671088660 = Port-channel 20
ifName.805306369 = eth0
ifName.805306370 = eth1
ifName.1207959553 = Ve 1
]
SNMP STATUS[TRUE]
ifType 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifType]

CMD EXITCODE[0]
CMD RUNTIME[0.1113s]
STDOUT[
ifType.201335168 = ethernetCsmacd
ifType.201343360 = ethernetCsmacd
ifType.201351552 = ethernetCsmacd
ifType.201359744 = ethernetCsmacd
ifType.201367936 = ethernetCsmacd
ifType.201376128 = ethernetCsmacd
ifType.201384320 = ethernetCsmacd
ifType.201392512 = ethernetCsmacd
ifType.201400704 = ethernetCsmacd
ifType.201408896 = ethernetCsmacd
ifType.201417088 = ethernetCsmacd
ifType.201425280 = ethernetCsmacd
ifType.201433472 = ethernetCsmacd
ifType.201441664 = ethernetCsmacd
ifType.201449856 = ethernetCsmacd
ifType.201458048 = ethernetCsmacd
ifType.201466240 = ethernetCsmacd
ifType.201474432 = ethernetCsmacd
ifType.201482624 = ethernetCsmacd
ifType.201490816 = ethernetCsmacd
ifType.201499008 = ethernetCsmacd
ifType.201507200 = ethernetCsmacd
ifType.201515392 = ethernetCsmacd
ifType.201523584 = ethernetCsmacd
ifType.201531776 = ethernetCsmacd
ifType.201539968 = ethernetCsmacd
ifType.201548160 = ethernetCsmacd
ifType.201556352 = ethernetCsmacd
ifType.201564544 = ethernetCsmacd
ifType.201572736 = ethernetCsmacd
ifType.201580928 = ethernetCsmacd
ifType.201589120 = ethernetCsmacd
ifType.201597312 = ethernetCsmacd
ifType.201605504 = ethernetCsmacd
ifType.201613696 = ethernetCsmacd
ifType.201621888 = ethernetCsmacd
ifType.201630080 = ethernetCsmacd
ifType.201638272 = ethernetCsmacd
ifType.201646464 = ethernetCsmacd
ifType.201654656 = ethernetCsmacd
ifType.201662848 = ethernetCsmacd
ifType.201671040 = ethernetCsmacd
ifType.201679232 = ethernetCsmacd
ifType.201687424 = ethernetCsmacd
ifType.201695616 = ethernetCsmacd
ifType.201703808 = ethernetCsmacd
ifType.201712000 = ethernetCsmacd
ifType.201720192 = ethernetCsmacd
ifType.201728256 = ethernetCsmacd
ifType.201736448 = ethernetCsmacd
ifType.201744640 = ethernetCsmacd
ifType.201752832 = ethernetCsmacd
ifType.201761024 = ethernetCsmacd
ifType.201769216 = ethernetCsmacd
ifType.201924736 = ethernetCsmacd
ifType.671088650 = other
ifType.671088660 = other
ifType.805306369 = ethernetCsmacd
ifType.805306370 = ethernetCsmacd
ifType.1207959553 = other
]
SNMP STATUS[TRUE]
ifOperStatus 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0859s]
STDOUT[
ifOperStatus.201335168 = up
ifOperStatus.201343360 = down
ifOperStatus.201351552 = up
ifOperStatus.201359744 = down
ifOperStatus.201367936 = down
ifOperStatus.201376128 = down
ifOperStatus.201384320 = down
ifOperStatus.201392512 = down
ifOperStatus.201400704 = down
ifOperStatus.201408896 = down
ifOperStatus.201417088 = down
ifOperStatus.201425280 = down
ifOperStatus.201433472 = down
ifOperStatus.201441664 = down
ifOperStatus.201449856 = down
ifOperStatus.201458048 = down
ifOperStatus.201466240 = down
ifOperStatus.201474432 = down
ifOperStatus.201482624 = down
ifOperStatus.201490816 = down
ifOperStatus.201499008 = down
ifOperStatus.201507200 = down
ifOperStatus.201515392 = down
ifOperStatus.201523584 = down
ifOperStatus.201531776 = down
ifOperStatus.201539968 = down
ifOperStatus.201548160 = down
ifOperStatus.201556352 = down
ifOperStatus.201564544 = down
ifOperStatus.201572736 = down
ifOperStatus.201580928 = down
ifOperStatus.201589120 = down
ifOperStatus.201597312 = down
ifOperStatus.201605504 = down
ifOperStatus.201613696 = down
ifOperStatus.201621888 = down
ifOperStatus.201630080 = down
ifOperStatus.201638272 = down
ifOperStatus.201646464 = down
ifOperStatus.201654656 = down
ifOperStatus.201662848 = down
ifOperStatus.201671040 = down
ifOperStatus.201679232 = down
ifOperStatus.201687424 = down
ifOperStatus.201695616 = down
ifOperStatus.201703808 = down
ifOperStatus.201712000 = down
ifOperStatus.201720192 = down
ifOperStatus.201728256 = down
ifOperStatus.201736448 = up
ifOperStatus.201744640 = up
ifOperStatus.201752832 = up
ifOperStatus.201761024 = down
ifOperStatus.201769216 = down
ifOperStatus.201924736 = down
ifOperStatus.671088650 = up
ifOperStatus.671088660 = up
ifOperStatus.805306369 = up
ifOperStatus.805306370 = up
ifOperStatus.1207959553 = up
]
SNMP STATUS[TRUE]



  /opt/observium/includes/discovery/ports.inc.php:45 
array(
  [201335168]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/1"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/1"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [201343360]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/2"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/2"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201351552]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/3"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/3"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [201359744]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/4"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/4"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201367936]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/5"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/5"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201376128]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/6"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/6"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201384320]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/7"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/7"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201392512]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/8"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/8"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201400704]  => array(
                    [ifDescr]      => string(12) "Ethernet 0/9"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(12) "Ethernet 0/9"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201408896]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/10"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/10"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201417088]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/11"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/11"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201425280]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/12"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/12"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201433472]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/13"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/13"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201441664]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/14"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/14"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201449856]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/15"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/15"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201458048]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/16"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/16"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201466240]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/17"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/17"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201474432]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/18"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/18"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201482624]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/19"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/19"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201490816]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/20"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/20"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201499008]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/21"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/21"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201507200]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/22"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/22"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201515392]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/23"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/23"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201523584]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/24"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/24"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201531776]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/25"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/25"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201539968]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/26"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/26"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201548160]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/27"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/27"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201556352]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/28"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/28"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201564544]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/29"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/29"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201572736]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/30"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/30"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201580928]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/31"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/31"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201589120]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/32"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/32"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201597312]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/33"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/33"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201605504]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/34"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/34"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201613696]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/35"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/35"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201621888]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/36"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/36"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201630080]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/37"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/37"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201638272]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/38"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/38"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201646464]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/39"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/39"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201654656]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/40"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/40"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201662848]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/41"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/41"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201671040]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/42"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/42"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201679232]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/43"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/43"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201687424]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/44"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/44"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201695616]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/45"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/45"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201703808]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/46"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/46"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201712000]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/47"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/47"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201720192]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/48"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/48"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201728256]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/49"
                    [ifAlias]      => string(12) "LAG_nexus1-2"
                    [ifName]       => string(13) "Ethernet 0/49"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201736448]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/50"
                    [ifAlias]      => string(12) "LAG_nexus1-2"
                    [ifName]       => string(13) "Ethernet 0/50"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [201744640]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/51"
                    [ifAlias]      => string(13) "LAG_eswrdc1-2"
                    [ifName]       => string(13) "Ethernet 0/51"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [201752832]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/52"
                    [ifAlias]      => string(13) "LAG_eswrdc1-2"
                    [ifName]       => string(13) "Ethernet 0/52"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [201761024]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/53"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/53"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201769216]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/54"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/54"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [201924736]  => array(
                    [ifDescr]      => string(13) "Ethernet 0/73"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(13) "Ethernet 0/73"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(4) "down"
                  )
  [671088650]  => array(
                    [ifDescr]      => string(15) "Port-channel 10"
                    [ifAlias]      => string(12) "LAG_nexus1-2"
                    [ifName]       => string(15) "Port-channel 10"
                    [ifType]       => string(5) "other"
                    [ifOperStatus] => string(2) "up"
                  )
  [671088660]  => array(
                    [ifDescr]      => string(15) "Port-channel 20"
                    [ifAlias]      => string(13) "LAG_eswrdc1-2"
                    [ifName]       => string(15) "Port-channel 20"
                    [ifType]       => string(5) "other"
                    [ifOperStatus] => string(2) "up"
                  )
  [805306369]  => array(
                    [ifDescr]      => string(4) "eth0"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(4) "eth0"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [805306370]  => array(
                    [ifDescr]      => string(4) "eth1"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(4) "eth1"
                    [ifType]       => string(14) "ethernetCsmacd"
                    [ifOperStatus] => string(2) "up"
                  )
  [1207959553] => array(
                    [ifDescr]      => string(4) "Ve 1"
                    [ifAlias]      => string(0) ""
                    [ifName]       => string(4) "Ve 1"
                    [ifType]       => string(5) "other"
                    [ifOperStatus] => string(2) "up"
                  )
)
 o Caching DB           
SQL[SELECT * FROM `ports` WHERE `device_id` = '716']
SQL RUNTIME[0.00112510s]
60 ports
 o Discovering ports    ............................................................
+------------+-----------------+-----------------+---------------+----------------+-------------+---------+
| ifIndex    | ifDescr         | ifName          | ifAlias       | ifType         | Oper Status | Ignored |
+------------+-----------------+-----------------+---------------+----------------+-------------+---------+
| 201335168  | Ethernet 0/1    | Ethernet 0/1    | ...           | ethernetCsmacd | up          | no      |
| 201343360  | Ethernet 0/2    | Ethernet 0/2    | ...           | ethernetCsmacd | down        | no      |
| 201351552  | Ethernet 0/3    | Ethernet 0/3    | ...           | ethernetCsmacd | up          | no      |
| 201359744  | Ethernet 0/4    | Ethernet 0/4    | ...           | ethernetCsmacd | down        | no      |
| 201367936  | Ethernet 0/5    | Ethernet 0/5    | ...           | ethernetCsmacd | down        | no      |
| 201376128  | Ethernet 0/6    | Ethernet 0/6    | ...           | ethernetCsmacd | down        | no      |
| 201384320  | Ethernet 0/7    | Ethernet 0/7    | ...           | ethernetCsmacd | down        | no      |
| 201392512  | Ethernet 0/8    | Ethernet 0/8    | ...           | ethernetCsmacd | down        | no      |
| 201400704  | Ethernet 0/9    | Ethernet 0/9    | ...           | ethernetCsmacd | down        | no      |
| 201408896  | Ethernet 0/10   | Ethernet 0/10   | ...           | ethernetCsmacd | down        | no      |
| 201417088  | Ethernet 0/11   | Ethernet 0/11   | ...           | ethernetCsmacd | down        | no      |
| 201425280  | Ethernet 0/12   | Ethernet 0/12   | ...           | ethernetCsmacd | down        | no      |
| 201433472  | Ethernet 0/13   | Ethernet 0/13   | ...           | ethernetCsmacd | down        | no      |
| 201441664  | Ethernet 0/14   | Ethernet 0/14   | ...           | ethernetCsmacd | down        | no      |
| 201449856  | Ethernet 0/15   | Ethernet 0/15   | ...           | ethernetCsmacd | down        | no      |
| 201458048  | Ethernet 0/16   | Ethernet 0/16   | ...           | ethernetCsmacd | down        | no      |
| 201466240  | Ethernet 0/17   | Ethernet 0/17   | ...           | ethernetCsmacd | down        | no      |
| 201474432  | Ethernet 0/18   | Ethernet 0/18   | ...           | ethernetCsmacd | down        | no      |
| 201482624  | Ethernet 0/19   | Ethernet 0/19   | ...           | ethernetCsmacd | down        | no      |
| 201490816  | Ethernet 0/20   | Ethernet 0/20   | ...           | ethernetCsmacd | down        | no      |
| 201499008  | Ethernet 0/21   | Ethernet 0/21   | ...           | ethernetCsmacd | down        | no      |
| 201507200  | Ethernet 0/22   | Ethernet 0/22   | ...           | ethernetCsmacd | down        | no      |
| 201515392  | Ethernet 0/23   | Ethernet 0/23   | ...           | ethernetCsmacd | down        | no      |
| 201523584  | Ethernet 0/24   | Ethernet 0/24   | ...           | ethernetCsmacd | down        | no      |
| 201531776  | Ethernet 0/25   | Ethernet 0/25   | ...           | ethernetCsmacd | down        | no      |
| 201539968  | Ethernet 0/26   | Ethernet 0/26   | ...           | ethernetCsmacd | down        | no      |
| 201548160  | Ethernet 0/27   | Ethernet 0/27   | ...           | ethernetCsmacd | down        | no      |
| 201556352  | Ethernet 0/28   | Ethernet 0/28   | ...           | ethernetCsmacd | down        | no      |
| 201564544  | Ethernet 0/29   | Ethernet 0/29   | ...           | ethernetCsmacd | down        | no      |
| 201572736  | Ethernet 0/30   | Ethernet 0/30   | ...           | ethernetCsmacd | down        | no      |
| 201580928  | Ethernet 0/31   | Ethernet 0/31   | ...           | ethernetCsmacd | down        | no      |
| 201589120  | Ethernet 0/32   | Ethernet 0/32   | ...           | ethernetCsmacd | down        | no      |
| 201597312  | Ethernet 0/33   | Ethernet 0/33   | ...           | ethernetCsmacd | down        | no      |
| 201605504  | Ethernet 0/34   | Ethernet 0/34   | ...           | ethernetCsmacd | down        | no      |
| 201613696  | Ethernet 0/35   | Ethernet 0/35   | ...           | ethernetCsmacd | down        | no      |
| 201621888  | Ethernet 0/36   | Ethernet 0/36   | ...           | ethernetCsmacd | down        | no      |
| 201630080  | Ethernet 0/37   | Ethernet 0/37   | ...           | ethernetCsmacd | down        | no      |
| 201638272  | Ethernet 0/38   | Ethernet 0/38   | ...           | ethernetCsmacd | down        | no      |
| 201646464  | Ethernet 0/39   | Ethernet 0/39   | ...           | ethernetCsmacd | down        | no      |
| 201654656  | Ethernet 0/40   | Ethernet 0/40   | ...           | ethernetCsmacd | down        | no      |
| 201662848  | Ethernet 0/41   | Ethernet 0/41   | ...           | ethernetCsmacd | down        | no      |
| 201671040  | Ethernet 0/42   | Ethernet 0/42   | ...           | ethernetCsmacd | down        | no      |
| 201679232  | Ethernet 0/43   | Ethernet 0/43   | ...           | ethernetCsmacd | down        | no      |
| 201687424  | Ethernet 0/44   | Ethernet 0/44   | ...           | ethernetCsmacd | down        | no      |
| 201695616  | Ethernet 0/45   | Ethernet 0/45   | ...           | ethernetCsmacd | down        | no      |
| 201703808  | Ethernet 0/46   | Ethernet 0/46   | ...           | ethernetCsmacd | down        | no      |
| 201712000  | Ethernet 0/47   | Ethernet 0/47   | ...           | ethernetCsmacd | down        | no      |
| 201720192  | Ethernet 0/48   | Ethernet 0/48   | ...           | ethernetCsmacd | down        | no      |
| 201728256  | Ethernet 0/49   | Ethernet 0/49   | LAG_nexus1-2  | ethernetCsmacd | down        | no      |
| 201736448  | Ethernet 0/50   | Ethernet 0/50   | LAG_nexus1-2  | ethernetCsmacd | up          | no      |
| 201744640  | Ethernet 0/51   | Ethernet 0/51   | LAG_eswrdc1-2 | ethernetCsmacd | up          | no      |
| 201752832  | Ethernet 0/52   | Ethernet 0/52   | LAG_eswrdc1-2 | ethernetCsmacd | up          | no      |
| 201761024  | Ethernet 0/53   | Ethernet 0/53   | ...           | ethernetCsmacd | down        | no      |
| 201769216  | Ethernet 0/54   | Ethernet 0/54   | ...           | ethernetCsmacd | down        | no      |
| 201924736  | Ethernet 0/73   | Ethernet 0/73   | ...           | ethernetCsmacd | down        | no      |
| 671088650  | Port-channel 10 | Port-channel 10 | LAG_nexus1-2  | other          | up          | no      |
| 671088660  | Port-channel 20 | Port-channel 20 | LAG_eswrdc1-2 | other          | up          | no      |
| 805306369  | eth0            | eth0            | ...           | ethernetCsmacd | up          | no      |
| 805306370  | eth1            | eth1            | ...           | ethernetCsmacd | up          | no      |
| 1207959553 | Ve 1            | Ve 1            | ...           | other          | up          | no      |
+------------+-----------------+-----------------+---------------+----------------+-------------+---------+


 o Duration             1.2351s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_ports-stack']
SQL RUNTIME[0.00034595s]
#####  Module Start: ports-stack  #####


SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '716']
SQL RUNTIME[0.00018597s]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ifStackStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.7296s]
STDOUT[
ifStackStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


 o Duration             0.7323s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_vlans']
SQL RUNTIME[0.00058699s]
#####  Module Start: vlans  #####


SQL[SELECT * FROM `vlans` WHERE `device_id` = '716';]
SQL RUNTIME[0.00024796s]

SQL[SELECT * FROM `ports_vlans` WHERE `device_id` = '716';]
SQL RUNTIME[0.00020218s]
 o EXTREME-VLAN-MIB     
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m EXTREME-VLAN-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/extreme 'udp':'slx9140':'161' extremeVlanIfDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0499s]
STDOUT[
extremeVlanIfDescr = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m EXTREME-VLAN-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/extreme 'udp':'slx9140':'161' extremeStatsVlanNameIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0468s]
STDOUT[
extremeStatsVlanNameIndex = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]



 o Duration             0.1021s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_oids']
SQL RUNTIME[0.00043917s]
#####  Module Start: oids  #####


SQL[SELECT * FROM  `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '716']
SQL RUNTIME[0.00038695s]

SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1']
SQL RUNTIME[0.00019097s]

 o Duration             0.0013s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_cisco-vrf']
SQL RUNTIME[0.00023890s]
#####  Module Start: cisco-vrf  #####


 o Duration             0.0003s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_ip-addresses']
SQL RUNTIME[0.00025296s]
#####  Module Start: ip-addresses  #####

 o IP-MIB               
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAdEntIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0275s]
STDOUT[
ipAdEntIfIndex = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAdEntNetMask]

CMD EXITCODE[0]
CMD RUNTIME[0.026s]
STDOUT[
ipAdEntNetMask = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAddressIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0254s]
STDOUT[
ipAddressIfIndex.ipv4."160.103.1.73" = 1207959553
ipAddressIfIndex.ipv4."172.19.8.103" = 1026
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAddressType]

CMD EXITCODE[0]
CMD RUNTIME[0.0267s]
STDOUT[
ipAddressType.ipv4."160.103.1.73" = unicast
ipAddressType.ipv4."172.19.8.103" = unicast
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAddressPrefix]

CMD EXITCODE[0]
CMD RUNTIME[0.0217s]
STDOUT[
ipAddressPrefix.ipv4."160.103.1.73" = zeroDotZero
ipAddressPrefix.ipv4."172.19.8.103" = zeroDotZero
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipAddressOrigin]

CMD EXITCODE[0]
CMD RUNTIME[0.0195s]
STDOUT[
ipAddressOrigin.ipv4."160.103.1.73" = manual
ipAddressOrigin.ipv4."172.19.8.103" = manual
]
SNMP STATUS[TRUE]
Added 160.103.1.73
.Added 172.19.8.103
.
 o IPV6-MIB             
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUsb -m IPV6-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipv6AddrEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.2228s]
STDOUT[
ipv6AddrEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o SWSYSTEM-MIB          [
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swEtherIPAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0886s]
STDOUT[
swEtherIPAddress.0 = 172.19.8.103
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swEtherIPAddress

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swEtherIPMask]

CMD EXITCODE[0]
CMD RUNTIME[0.1803s]
STDOUT[
swEtherIPMask.0 = 255.255.255.0
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swEtherIPMask
Found ifIndex 1026 for IP 172.19.8.103
Already exist 172.19.8.103, updated params [mask, prefix]
] 

SQL[SELECT * FROM `ipv4_addresses`
            WHERE `device_id` = '716']
SQL RUNTIME[0.00058985s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '1207959553' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00032496s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '62386']
SQL RUNTIME[0.00039887s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '62386']
SQL RUNTIME[0.00010896s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '716']
SQL RUNTIME[0.00033808s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '716']
SQL RUNTIME[0.00012207s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '160.103.1.73/32']
SQL RUNTIME[0.00043607s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '1026' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00025415s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.19.8.0/24']
SQL RUNTIME[0.00008607s]

SQL[SELECT * FROM `ipv4_addresses`
            WHERE `device_id` = '716']
SQL RUNTIME[0.00007510s]

SQL[SELECT * FROM `ipv6_addresses`
            WHERE `device_id` = '716']
SQL RUNTIME[0.00026083s]
+------------+---------+-------------+-----------------+-----------------+---------+--------+
| ifIndex    | ifDescr | IP: Version | Address         | Network         | Type    | Origin |
+------------+---------+-------------+-----------------+-----------------+---------+--------+
| 1207959553 | Ve 1    | IPv4        | 160.103.1.73/32 | 160.103.1.73/32 | unicast | manual |
| 1026       | ...     | IPv4        | 172.19.8.103/24 | 172.19.8.0/24   | private | manual |
+------------+---------+-------------+-----------------+-----------------+---------+--------+


 o Changes              2 unchanged
 o Duration             0.6709s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_processors']
SQL RUNTIME[0.00035000s]
#####  Module Start: processors  #####

 o UCD-SNMP-MIB         
SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '716' AND `processor_type` != 'ucd-old')]
SQL RUNTIME[0.00030398s]

 o SWSYSTEM-MIB         
CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swCpuUsage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0105s]
STDOUT[
23
]
SNMP STATUS[TRUE]
716 -> .1.3.6.1.4.1.1588.2.1.1.1.26.1.0, 0, swCpuUsage, CPU, 1, 23, , 

SQL[SELECT * FROM `processors` WHERE `device_id` = '716' AND `processor_index` = '0' AND `processor_type` = 'swCpuUsage']
SQL RUNTIME[0.00055504s]

SQL[SELECT * FROM `processors` WHERE `device_id` = '716']
SQL RUNTIME[0.00023508s]
0 -> swCpuUsage


 > $valid['processor'] /opt/observium/includes/discovery/processors.inc.php:164 
array(
  [swCpuUsage] => array(
                    [0] => int(1)
                  )
)

 o Changes              1 unchanged
 o Duration             0.0145s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_mempools']
SQL RUNTIME[0.00036407s]
#####  Module Start: mempools  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0124s]
STDOUT[
memTotalReal.0 = No Such Object available on this agent at this OID
memAvailReal.0 = No Such Object available on this agent at this OID
memBuffer.0 = No Such Object available on this agent at this OID
memCached.0 = No Such Object available on this agent at this OID
]
SNMP ERROR[#1000 - Failed response]
SNMP STATUS[FALSE]

BROCADE-MODULE-MEM-UTIL-MIB 
CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m BROCADE-MODULE-MEM-UTIL-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' bcsiModuleMemTotal.1]

CMD EXITCODE[0]
CMD RUNTIME[0.0064s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m BROCADE-MODULE-MEM-UTIL-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' bcsiModuleMemAvailable.1]

CMD EXITCODE[0]
CMD RUNTIME[0.0051s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
SWSYSTEM-MIB 
CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swMemUsage.0]

CMD EXITCODE[0]
CMD RUNTIME[0.01s]
STDOUT[
27
]
SNMP STATUS[TRUE]
716 -> 0, SWSYSTEM-MIB::swMemUsage, Memory, 1, 2147483648, 579820584.96

SQL[SELECT * FROM `mempools` WHERE `device_id` = '716' AND `mempool_index` = '0' AND `mempool_mib` = 'SWSYSTEM-MIB']
SQL RUNTIME[0.00063896s]

SQL[SELECT * FROM `mempools` WHERE `device_id` = '716']
SQL RUNTIME[0.00027299s]
0 -> SWSYSTEM-MIB


 > $valid['mempool'] /opt/observium/includes/discovery/mempools.inc.php:216 
array(
  [SWSYSTEM-MIB] => array(
                      [0] => int(1)
                    )
)

 o Changes              1 unchanged
 o Duration             0.0427s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_inventory']
SQL RUNTIME[0.00040412s]
#####  Module Start: inventory  #####

 o ENTITY-MIB           ENTITY-MIB 
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'slx9140':'161' entPhysicalEntry]

CMD EXITCODE[0]
CMD RUNTIME[17.9849s]
STDOUT[
entPhysicalDescr.1 = Extreme BR-SLX9140 Chassis
entPhysicalDescr.2 = MODULE
entPhysicalDescr.3 = FAN SLOT
entPhysicalDescr.4 = FAN
entPhysicalDescr.5 = FAN SLOT
entPhysicalDescr.6 = FAN
entPhysicalDescr.9 = FAN SLOT
entPhysicalDescr.10 = FAN
entPhysicalDescr.11 = FAN SLOT
entPhysicalDescr.12 = FAN
entPhysicalDescr.13 = FAN SLOT
entPhysicalDescr.14 = FAN
entPhysicalDescr.15 = POWER SUPPLY SLOT
entPhysicalDescr.16 = POWER SUPPLY
entPhysicalDescr.17 = POWER SUPPLY SLOT
entPhysicalDescr.18 = POWER SUPPLY
entPhysicalDescr.19 = OTHER
entPhysicalVendorType.1 = zeroDotZero
entPhysicalVendorType.2 = zeroDotZero
entPhysicalVendorType.3 = zeroDotZero
entPhysicalVendorType.4 = zeroDotZero
entPhysicalVendorType.5 = zeroDotZero
entPhysicalVendorType.6 = zeroDotZero
entPhysicalVendorType.9 = zeroDotZero
entPhysicalVendorType.10 = zeroDotZero
entPhysicalVendorType.11 = zeroDotZero
entPhysicalVendorType.12 = zeroDotZero
entPhysicalVendorType.13 = zeroDotZero
entPhysicalVendorType.14 = zeroDotZero
entPhysicalVendorType.15 = zeroDotZero
entPhysicalVendorType.16 = zeroDotZero
entPhysicalVendorType.17 = zeroDotZero
entPhysicalVendorType.18 = zeroDotZero
entPhysicalVendorType.19 = zeroDotZero
entPhysicalContainedIn.1 = 0
entPhysicalContainedIn.2 = 1
entPhysicalContainedIn.3 = 1
entPhysicalContainedIn.4 = 3
entPhysicalContainedIn.5 = 1
entPhysicalContainedIn.6 = 5
entPhysicalContainedIn.9 = 1
entPhysicalContainedIn.10 = 9
entPhysicalContainedIn.11 = 1
entPhysicalContainedIn.12 = 11
entPhysicalContainedIn.13 = 1
entPhysicalContainedIn.14 = 13
entPhysicalContainedIn.15 = 1
entPhysicalContainedIn.16 = 15
entPhysicalContainedIn.17 = 1
entPhysicalContainedIn.18 = 17
entPhysicalContainedIn.19 = 1
entPhysicalClass.1 = chassis
entPhysicalClass.2 = module
entPhysicalClass.3 = container
entPhysicalClass.4 = fan
entPhysicalClass.5 = container
entPhysicalClass.6 = fan
entPhysicalClass.9 = container
entPhysicalClass.10 = fan
entPhysicalClass.11 = container
entPhysicalClass.12 = fan
entPhysicalClass.13 = container
entPhysicalClass.14 = fan
entPhysicalClass.15 = container
entPhysicalClass.16 = powerSupply
entPhysicalClass.17 = container
entPhysicalClass.18 = powerSupply
entPhysicalClass.19 = other
entPhysicalParentRelPos.1 = -1
entPhysicalParentRelPos.2 = 1
entPhysicalParentRelPos.3 = 2
entPhysicalParentRelPos.4 = 1
entPhysicalParentRelPos.5 = 3
entPhysicalParentRelPos.6 = 1
entPhysicalParentRelPos.9 = 4
entPhysicalParentRelPos.10 = 1
entPhysicalParentRelPos.11 = 5
entPhysicalParentRelPos.12 = 1
entPhysicalParentRelPos.13 = 6
entPhysicalParentRelPos.14 = 1
entPhysicalParentRelPos.15 = 7
entPhysicalParentRelPos.16 = 1
entPhysicalParentRelPos.17 = 8
entPhysicalParentRelPos.18 = 1
entPhysicalParentRelPos.19 = 9
entPhysicalName.1 = BR-SLX9140
entPhysicalName.2 = MODULE 0
entPhysicalName.3 = FAN  1
entPhysicalName.4 = FAN  1
entPhysicalName.5 = FAN  2
entPhysicalName.6 = FAN  2
entPhysicalName.9 = FAN  4
entPhysicalName.10 = FAN  4
entPhysicalName.11 = FAN  5
entPhysicalName.12 = FAN  5
entPhysicalName.13 = FAN  6
entPhysicalName.14 = FAN  6
entPhysicalName.15 = POWER SUPPLY  1
entPhysicalName.16 = POWER SUPPLY  1
entPhysicalName.17 = POWER SUPPLY  2
entPhysicalName.18 = POWER SUPPLY  2
entPhysicalName.19 = OTHER
entPhysicalHardwareRev.1 = 
entPhysicalHardwareRev.2 = 
entPhysicalHardwareRev.3 = 
entPhysicalHardwareRev.4 = 
entPhysicalHardwareRev.5 = 
entPhysicalHardwareRev.6 = 
entPhysicalHardwareRev.9 = 
entPhysicalHardwareRev.10 = 
entPhysicalHardwareRev.11 = 
entPhysicalHardwareRev.12 = 
entPhysicalHardwareRev.13 = 
entPhysicalHardwareRev.14 = 
entPhysicalHardwareRev.15 = 
entPhysicalHardwareRev.16 = 
entPhysicalHardwareRev.17 = 
entPhysicalHardwareRev.18 = 
entPhysicalHardwareRev.19 = 
entPhysicalFirmwareRev.1 = 
entPhysicalFirmwareRev.2 = 
entPhysicalFirmwareRev.3 = 
entPhysicalFirmwareRev.4 = 
entPhysicalFirmwareRev.5 = 
entPhysicalFirmwareRev.6 = 
entPhysicalFirmwareRev.9 = 
entPhysicalFirmwareRev.10 = 
entPhysicalFirmwareRev.11 = 
entPhysicalFirmwareRev.12 = 
entPhysicalFirmwareRev.13 = 
entPhysicalFirmwareRev.14 = 
entPhysicalFirmwareRev.15 = 
entPhysicalFirmwareRev.16 = 
entPhysicalFirmwareRev.17 = 
entPhysicalFirmwareRev.18 = 
entPhysicalFirmwareRev.19 = 
entPhysicalSoftwareRev.1 = 
entPhysicalSoftwareRev.2 = 
entPhysicalSoftwareRev.3 = 
entPhysicalSoftwareRev.4 = 
entPhysicalSoftwareRev.5 = 
entPhysicalSoftwareRev.6 = 
entPhysicalSoftwareRev.9 = 
entPhysicalSoftwareRev.10 = 
entPhysicalSoftwareRev.11 = 
entPhysicalSoftwareRev.12 = 
entPhysicalSoftwareRev.13 = 
entPhysicalSoftwareRev.14 = 
entPhysicalSoftwareRev.15 = 
entPhysicalSoftwareRev.16 = 
entPhysicalSoftwareRev.17 = 
entPhysicalSoftwareRev.18 = 
entPhysicalSoftwareRev.19 = 
entPhysicalSerialNum.1 = ************
entPhysicalSerialNum.2 = 
entPhysicalSerialNum.3 = 
entPhysicalSerialNum.4 = 
entPhysicalSerialNum.5 = 
entPhysicalSerialNum.6 = 
entPhysicalSerialNum.9 = 
entPhysicalSerialNum.10 = 
entPhysicalSerialNum.11 = 
entPhysicalSerialNum.12 = 
entPhysicalSerialNum.13 = 
entPhysicalSerialNum.14 = 
entPhysicalSerialNum.15 = 
entPhysicalSerialNum.16 = EWZ2T48P1DT 
entPhysicalSerialNum.17 = 
entPhysicalSerialNum.18 = EWZ2T48P1LD 
entPhysicalSerialNum.19 = ************
entPhysicalMfgName.1 = Extreme Networks, Inc
entPhysicalMfgName.2 = Extreme Networks, Inc
entPhysicalMfgName.3 = 
entPhysicalMfgName.4 = Extreme Networks, Inc
entPhysicalMfgName.5 = 
entPhysicalMfgName.6 = Extreme Networks, Inc
entPhysicalMfgName.9 = 
entPhysicalMfgName.10 = Extreme Networks, Inc
entPhysicalMfgName.11 = 
entPhysicalMfgName.12 = Extreme Networks, Inc
entPhysicalMfgName.13 = 
entPhysicalMfgName.14 = Extreme Networks, Inc
entPhysicalMfgName.15 = 
entPhysicalMfgName.16 = Extreme Networks, Inc
entPhysicalMfgName.17 = 
entPhysicalMfgName.18 = Extreme Networks, Inc
entPhysicalMfgName.19 = Extreme Networks, Inc
entPhysicalModelName.1 = 84-1002952-01
entPhysicalModelName.2 = 
entPhysicalModelName.3 = 
entPhysicalModelName.4 = 
entPhysicalModelName.5 = 
entPhysicalModelName.6 = 
entPhysicalModelName.9 = 
entPhysicalModelName.10 = 
entPhysicalModelName.11 = 
entPhysicalModelName.12 = 
entPhysicalModelName.13 = 
entPhysicalModelName.14 = 
entPhysicalModelName.15 = 
entPhysicalModelName.16 = 23-1000075-02
entPhysicalModelName.17 = 
entPhysicalModelName.18 = 23-1000075-02
entPhysicalModelName.19 = 84-1002952-01
entPhysicalAlias.1 = 
entPhysicalAlias.2 = 
entPhysicalAlias.3 = 
entPhysicalAlias.4 = 
entPhysicalAlias.5 = 
entPhysicalAlias.6 = 
entPhysicalAlias.9 = 
entPhysicalAlias.10 = 
entPhysicalAlias.11 = 
entPhysicalAlias.12 = 
entPhysicalAlias.13 = 
entPhysicalAlias.14 = 
entPhysicalAlias.15 = 
entPhysicalAlias.16 = 
entPhysicalAlias.17 = 
entPhysicalAlias.18 = 
entPhysicalAlias.19 = 
entPhysicalAssetID.1 = 
entPhysicalAssetID.2 = 
entPhysicalAssetID.3 = 
entPhysicalAssetID.4 = 
entPhysicalAssetID.5 = 
entPhysicalAssetID.6 = 
entPhysicalAssetID.9 = 
entPhysicalAssetID.10 = 
entPhysicalAssetID.11 = 
entPhysicalAssetID.12 = 
entPhysicalAssetID.13 = 
entPhysicalAssetID.14 = 
entPhysicalAssetID.15 = 
entPhysicalAssetID.16 = 
entPhysicalAssetID.17 = 
entPhysicalAssetID.18 = 
entPhysicalAssetID.19 = 
entPhysicalIsFRU.1 = true
entPhysicalIsFRU.2 = false
entPhysicalIsFRU.3 = false
entPhysicalIsFRU.4 = true
entPhysicalIsFRU.5 = false
entPhysicalIsFRU.6 = true
entPhysicalIsFRU.9 = false
entPhysicalIsFRU.10 = true
entPhysicalIsFRU.11 = false
entPhysicalIsFRU.12 = true
entPhysicalIsFRU.13 = false
entPhysicalIsFRU.14 = true
entPhysicalIsFRU.15 = false
entPhysicalIsFRU.16 = true
entPhysicalIsFRU.17 = false
entPhysicalIsFRU.18 = true
entPhysicalIsFRU.19 = false
entPhysicalMfgDate.1 = 
entPhysicalMfgDate.2 = 
entPhysicalMfgDate.3 = 
entPhysicalMfgDate.4 = 
entPhysicalMfgDate.5 = 
entPhysicalMfgDate.6 = 
entPhysicalMfgDate.9 = 
entPhysicalMfgDate.10 = 
entPhysicalMfgDate.11 = 
entPhysicalMfgDate.12 = 
entPhysicalMfgDate.13 = 
entPhysicalMfgDate.14 = 
entPhysicalMfgDate.15 = 
entPhysicalMfgDate.16 = 
entPhysicalMfgDate.17 = 
entPhysicalMfgDate.18 = 
entPhysicalMfgDate.19 = 2019-10-24
entPhysicalUris.1 = ""
entPhysicalUris.2 = ""
entPhysicalUris.3 = ""
entPhysicalUris.4 = ""
entPhysicalUris.5 = ""
entPhysicalUris.6 = ""
entPhysicalUris.9 = ""
entPhysicalUris.10 = ""
entPhysicalUris.11 = ""
entPhysicalUris.12 = ""
entPhysicalUris.13 = ""
entPhysicalUris.14 = ""
entPhysicalUris.15 = ""
entPhysicalUris.16 = ""
entPhysicalUris.17 = ""
entPhysicalUris.18 = ""
entPhysicalUris.19 = ""
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' entAliasMappingIdentifier]

CMD EXITCODE[0]
CMD RUNTIME[0.0192s]
STDOUT[
entAliasMappingIdentifier = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '1' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00098085s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '2' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00055909s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '3' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00053501s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '4' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00057912s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '5' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00061917s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '6' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00058007s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '9' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00054908s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '10' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00051188s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '11' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00050592s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '12' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00055504s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '13' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00036502s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '14' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00035501s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '15' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00044322s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '16' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00039411s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '17' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00036597s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '18' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00066495s]

SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716' AND `entPhysicalIndex` = '19' AND `inventory_mib` = 'ENTITY-MIB']
SQL RUNTIME[0.00050211s]


SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '716']
SQL RUNTIME[0.00057006s]


 > $valid[$module] /opt/observium/includes/discovery/inventory.inc.php:22 
array(
  [ENTITY-MIB] => array(
                    [1]  => int(1)
                    [2]  => int(1)
                    [3]  => int(1)
                    [4]  => int(1)
                    [5]  => int(1)
                    [6]  => int(1)
                    [9]  => int(1)
                    [10] => int(1)
                    [11] => int(1)
                    [12] => int(1)
                    [13] => int(1)
                    [14] => int(1)
                    [15] => int(1)
                    [16] => int(1)
                    [17] => int(1)
                    [18] => int(1)
                    [19] => int(1)
                  )
)

 o Changes              17 unchanged
 o Duration             18.0264s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_printersupplies']
SQL RUNTIME[0.00057793s]
#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '716']
SQL RUNTIME[0.00041509s]


 o Duration             0.0011s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_sensors']
SQL RUNTIME[0.00033092s]
#####  Module Start: sensors  #####

 o SWSYSTEM-MIB         swSensorValue [
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swSensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0573s]
STDOUT[
swSensorValue.1 = 28
swSensorValue.2 = 30
swSensorValue.3 = 34
swSensorValue.4 = 25
swSensorValue.5 = 7689
swSensorValue.6 = 7873
swSensorValue.7 = -2147483648
swSensorValue.8 = 7689
swSensorValue.9 = 7689
swSensorValue.10 = 7873
swSensorValue.11 = 1
swSensorValue.12 = 1
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swSensorValue

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swSensorInfo]

CMD EXITCODE[0]
CMD RUNTIME[0.1252s]
STDOUT[
swSensorInfo.1 = "SLOT #0: TEMP #1"
swSensorInfo.2 = "SLOT #0: TEMP #2"
swSensorInfo.3 = "SLOT #0: TEMP #3"
swSensorInfo.4 = "SLOT #0: TEMP #4"
swSensorInfo.5 = " FAN #1"
swSensorInfo.6 = " FAN #2"
swSensorInfo.7 = " FAN #3"
swSensorInfo.8 = " FAN #4"
swSensorInfo.9 = " FAN #5"
swSensorInfo.10 = " FAN #6"
swSensorInfo.11 = " Power Supply #1"
swSensorInfo.12 = " Power Supply #2"
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swSensorInfo

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swSensorType]

CMD EXITCODE[0]
CMD RUNTIME[0.0487s]
STDOUT[
swSensorType.1 = temperature
swSensorType.2 = temperature
swSensorType.3 = temperature
swSensorType.4 = temperature
swSensorType.5 = fan
swSensorType.6 = fan
swSensorType.7 = fan
swSensorType.8 = fan
swSensorType.9 = fan
swSensorType.10 = fan
swSensorType.11 = power-supply
swSensorType.12 = power-supply
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swSensorType

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swSensorStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0592s]
STDOUT[
swSensorStatus.1 = nominal
swSensorStatus.2 = nominal
swSensorStatus.3 = nominal
swSensorStatus.4 = nominal
swSensorStatus.5 = nominal
swSensorStatus.6 = nominal
swSensorStatus.7 = absent
swSensorStatus.8 = nominal
swSensorStatus.9 = nominal
swSensorStatus.10 = nominal
swSensorStatus.11 = nominal
swSensorStatus.12 = nominal
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swSensorStatus
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.1, index: 1, type: SWSYSTEM-MIB-swSensorValue, descr: SLOT #0: TEMP #1, scale: 1, limits: (, , , ), CURRENT: 28, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '1')]
SQL RUNTIME[0.00095105s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '1']
SQL RUNTIME[0.00064778s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26285' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020695s]
.Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.2, index: 2, type: SWSYSTEM-MIB-swSensorValue, descr: SLOT #0: TEMP #2, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '2')]
SQL RUNTIME[0.00041890s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '2']
SQL RUNTIME[0.00060797s]
LCurrent sensor value: "30", scale: "1"
  limit_high: "46.4" -> "48"
  limit_high_warn: "" -> ""
  limit_low: "0" -> "0"
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='48' WHERE `sensor_id` = '26286']
SQL RUNTIME[0.00155997s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26286' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00036216s]
.Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.3, index: 3, type: SWSYSTEM-MIB-swSensorValue, descr: SLOT #0: TEMP #3, scale: 1, limits: (, , , ), CURRENT: 34, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '3')]
SQL RUNTIME[0.00072598s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '3']
SQL RUNTIME[0.00063491s]
LCurrent sensor value: "34", scale: "1"
  limit_high: "52.8" -> "54.4"
  limit_high_warn: "" -> ""
  limit_low: "0" -> "0"
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='54.4' WHERE `sensor_id` = '26287']
SQL RUNTIME[0.00126505s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26287' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00023103s]
.Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.4, index: 4, type: SWSYSTEM-MIB-swSensorValue, descr: SLOT #0: TEMP #4, scale: 1, limits: (, , , ), CURRENT: 25, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '4')]
SQL RUNTIME[0.00039387s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '4']
SQL RUNTIME[0.00054717s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26288' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00017405s]
.Discover sensor: [class: fanspeed, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.5, index: 5, type: SWSYSTEM-MIB-swSensorValue, descr:  FAN #1, scale: 1, limits: (, , , ), CURRENT: 7689, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '5')]
SQL RUNTIME[0.00037909s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '5']
SQL RUNTIME[0.00064301s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26289' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00021410s]
.Discover sensor: [class: fanspeed, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.6, index: 6, type: SWSYSTEM-MIB-swSensorValue, descr:  FAN #2, scale: 1, limits: (, , , ), CURRENT: 7873, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '6')]
SQL RUNTIME[0.00043106s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '6']
SQL RUNTIME[0.00057793s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26290' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020289s]
.Excluded by not test condition: swSensorStatus [absent] != [absent]
Discover sensor: [class: fanspeed, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.8, index: 8, type: SWSYSTEM-MIB-swSensorValue, descr:  FAN #4, scale: 1, limits: (, , , ), CURRENT: 7689, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '8')]
SQL RUNTIME[0.00038505s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '8']
SQL RUNTIME[0.00058389s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26291' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019193s]
.Discover sensor: [class: fanspeed, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.9, index: 9, type: SWSYSTEM-MIB-swSensorValue, descr:  FAN #5, scale: 1, limits: (, , , ), CURRENT: 7689, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '9')]
SQL RUNTIME[0.00047803s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '9']
SQL RUNTIME[0.00059319s]
LCurrent sensor value: "7689", scale: "1"
  limit_high: "14171.4" -> "13840.2"
  limit_high_warn: "" -> ""
  limit_low: "6298.4" -> "6151.2"
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='13840.2',`sensor_limit_low` ='6151.2' WHERE `sensor_id` = '26292']
SQL RUNTIME[0.00132489s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26292' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020194s]
.Discover sensor: [class: fanspeed, device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4.10, index: 10, type: SWSYSTEM-MIB-swSensorValue, descr:  FAN #6, scale: 1, limits: (, , , ), CURRENT: 7873, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '10')]
SQL RUNTIME[0.00042295s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '716' AND `sensor_type` = 'SWSYSTEM-MIB-swSensorValue' AND `sensor_index` = '10']
SQL RUNTIME[0.00077701s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26293' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00034499s]
.Value from oid_class (power-supply) does not match any configured values in map_class!
Value from oid_class (power-supply) does not match any configured values in map_class!
] 
 o SWSYSTEM-MIB         swOperStatus [
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m SWSYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' swOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0971s]
STDOUT[
swOperStatus.0 = online
]
SNMP STATUS[TRUE]
Store in cache Table OID: SWSYSTEM-MIB::swOperStatus
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.1.1.1.7.0, index: 0, type: swOperStatus, descr: Switch Status, CURRENT: 1, , system]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'SWSYSTEM-MIB' AND `status_object` = 'swOperStatus' AND `status_type` = 'swOperStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00079799s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'SWSYSTEM-MIB' AND `status_object` = 'swOperStatus' AND `status_type` = 'swOperStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00049210s]
.] 
 o HA-MIB               haStatus [
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m HA-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' haStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0247s]
STDOUT[
haStatus.0 = nonredundant
]
SNMP STATUS[TRUE]
Store in cache Table OID: HA-MIB::haStatus
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.1.0, index: 0, type: haStatus, descr: System Redundant Status, CURRENT: 1, , system]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'haStatus' AND `status_type` = 'haStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00075102s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'haStatus' AND `status_type` = 'haStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00039506s]
.] fruStatus [
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m HA-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' fruStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0327s]
STDOUT[
fruStatus.1 = on
fruStatus.4 = on
fruStatus.6 = on
fruStatus.10 = on
fruStatus.12 = on
fruStatus.14 = on
fruStatus.16 = on
fruStatus.18 = on
]
SNMP STATUS[TRUE]
Store in cache Table OID: HA-MIB::fruStatus

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m HA-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' fruClass]

CMD EXITCODE[0]
CMD RUNTIME[0.026s]
STDOUT[
fruClass.1 = chassis
fruClass.4 = fan
fruClass.6 = fan
fruClass.10 = fan
fruClass.12 = fan
fruClass.14 = fan
fruClass.16 = powerSupply
fruClass.18 = powerSupply
]
SNMP STATUS[TRUE]
Store in cache Table OID: HA-MIB::fruClass

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -Ih -OQUsb -m ENTITY-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' entPhysicalName]

CMD EXITCODE[0]
CMD RUNTIME[1.3513s]
STDOUT[
entPhysicalName.1 = "BR-SLX9140"
entPhysicalName.2 = "MODULE 0"
entPhysicalName.3 = "FAN  1"
entPhysicalName.4 = "FAN  1"
entPhysicalName.5 = "FAN  2"
entPhysicalName.6 = "FAN  2"
entPhysicalName.9 = "FAN  4"
entPhysicalName.10 = "FAN  4"
entPhysicalName.11 = "FAN  5"
entPhysicalName.12 = "FAN  5"
entPhysicalName.13 = "FAN  6"
entPhysicalName.14 = "FAN  6"
entPhysicalName.15 = "POWER SUPPLY  1"
entPhysicalName.16 = "POWER SUPPLY  1"
entPhysicalName.17 = "POWER SUPPLY  2"
entPhysicalName.18 = "POWER SUPPLY  2"
entPhysicalName.19 = "OTHER"
]
SNMP STATUS[TRUE]
Store in cache Table OID: ENTITY-MIB::entPhysicalName

CMD[/usr/bin/snmptranslate -On -Pu -m HA-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'HA-MIB::fruStatus']

CMD EXITCODE[0]
CMD RUNTIME[0.0101s]
STDOUT[
.1.3.6.1.4.1.1588.2.1.2.1.5.1.2
]
SNMP TRANSLATE (CMD): 'HA-MIB::fruStatus' -> '.1.3.6.1.4.1.1588.2.1.2.1.5.1.2'
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.1, index: 1, type: fruStatus, descr: BR-SLX9140, CURRENT: 3, , chassis]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00042200s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041986s]
.Excluded by empty current value.
Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.4, index: 4, type: fruStatus, descr: FAN  1, CURRENT: 3, , fan]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00036001s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041008s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.6, index: 6, type: fruStatus, descr: FAN  2, CURRENT: 3, , fan]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '6' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00029898s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '6' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00039792s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.10, index: 10, type: fruStatus, descr: FAN  4, CURRENT: 3, , fan]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '10' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00035691s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '10' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00050187s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.12, index: 12, type: fruStatus, descr: FAN  5, CURRENT: 3, , fan]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '12' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031400s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '12' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00058198s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.14, index: 14, type: fruStatus, descr: FAN  6, CURRENT: 3, , fan]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '14' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00034523s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '14' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00040102s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.16, index: 16, type: fruStatus, descr: POWER SUPPLY  1, CURRENT: 3, , powerSupply]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '16' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00038218s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '16' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00046921s]
.Excluded by empty current value.
Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.2.1.2.1.5.1.2.18, index: 18, type: fruStatus, descr: POWER SUPPLY  2, CURRENT: 3, , powerSupply]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '18' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00044179s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'HA-MIB' AND `status_object` = 'fruStatus' AND `status_type` = 'fruStatus' AND `status_index` = '18' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00045705s]
.Excluded by empty current value.
] 
 o BROCADE-OPTICAL-MONITORING-MIB  
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m BROCADE-OPTICAL-MONITORING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/brocade 'udp':'slx9140':'161' bcsiOptMonLaneEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1454s]
STDOUT[
bcsiOptMonLaneTemperature.201335168.1 = Not Supported
bcsiOptMonLaneTemperature.201343360.1 = Not Supported
bcsiOptMonLaneTemperature.201351552.1 = 30 C Normal
bcsiOptMonLaneTemperature.201359744.1 = 30 C Normal
bcsiOptMonLaneTemperature.201720192.1 = 27 C Normal
bcsiOptMonLaneTemperature.201728256.1 = 30 C Normal
bcsiOptMonLaneTemperature.201728256.2 = 30 C Normal
bcsiOptMonLaneTemperature.201728256.3 = 30 C Normal
bcsiOptMonLaneTemperature.201728256.4 = 30 C Normal
bcsiOptMonLaneTemperature.201736448.1 = 39 C Normal
bcsiOptMonLaneTemperature.201736448.2 = 39 C Normal
bcsiOptMonLaneTemperature.201736448.3 = 39 C Normal
bcsiOptMonLaneTemperature.201736448.4 = 39 C Normal
bcsiOptMonLaneTemperature.201744640.1 = 36 C Normal
bcsiOptMonLaneTemperature.201744640.2 = 36 C Normal
bcsiOptMonLaneTemperature.201744640.3 = 36 C Normal
bcsiOptMonLaneTemperature.201744640.4 = 36 C Normal
bcsiOptMonLaneTemperature.201752832.1 = 38 C Normal
bcsiOptMonLaneTemperature.201752832.2 = 38 C Normal
bcsiOptMonLaneTemperature.201752832.3 = 38 C Normal
bcsiOptMonLaneTemperature.201752832.4 = 38 C Normal
bcsiOptMonLaneTxPowerStatus.201335168.1 = notSupported
bcsiOptMonLaneTxPowerStatus.201343360.1 = notSupported
bcsiOptMonLaneTxPowerStatus.201351552.1 = normal
bcsiOptMonLaneTxPowerStatus.201359744.1 = normal
bcsiOptMonLaneTxPowerStatus.201720192.1 = normal
bcsiOptMonLaneTxPowerStatus.201728256.1 = normal
bcsiOptMonLaneTxPowerStatus.201728256.2 = normal
bcsiOptMonLaneTxPowerStatus.201728256.3 = normal
bcsiOptMonLaneTxPowerStatus.201728256.4 = normal
bcsiOptMonLaneTxPowerStatus.201736448.1 = normal
bcsiOptMonLaneTxPowerStatus.201736448.2 = normal
bcsiOptMonLaneTxPowerStatus.201736448.3 = normal
bcsiOptMonLaneTxPowerStatus.201736448.4 = normal
bcsiOptMonLaneTxPowerStatus.201744640.1 = normal
bcsiOptMonLaneTxPowerStatus.201744640.2 = normal
bcsiOptMonLaneTxPowerStatus.201744640.3 = normal
bcsiOptMonLaneTxPowerStatus.201744640.4 = normal
bcsiOptMonLaneTxPowerStatus.201752832.1 = normal
bcsiOptMonLaneTxPowerStatus.201752832.2 = normal
bcsiOptMonLaneTxPowerStatus.201752832.3 = normal
bcsiOptMonLaneTxPowerStatus.201752832.4 = normal
bcsiOptMonLaneTxPower.201335168.1 = Not Supported
bcsiOptMonLaneTxPower.201343360.1 = Not Supported
bcsiOptMonLaneTxPower.201351552.1 = -2.275 dBm Normal
bcsiOptMonLaneTxPower.201359744.1 = -2.038 dBm Normal
bcsiOptMonLaneTxPower.201720192.1 = -0.370 dBm Normal
bcsiOptMonLaneTxPower.201728256.1 = -40.000 dBm Normal
bcsiOptMonLaneTxPower.201728256.2 = -40.000 dBm Normal
bcsiOptMonLaneTxPower.201728256.3 = -40.000 dBm Normal
bcsiOptMonLaneTxPower.201728256.4 = -40.000 dBm Normal
bcsiOptMonLaneTxPower.201736448.1 = 1.115 dBm Normal
bcsiOptMonLaneTxPower.201736448.2 = -1.270 dBm Normal
bcsiOptMonLaneTxPower.201736448.3 = 0.131 dBm Normal
bcsiOptMonLaneTxPower.201736448.4 = -0.767 dBm Normal
bcsiOptMonLaneTxPower.201744640.1 = 0.729 dBm Normal
bcsiOptMonLaneTxPower.201744640.2 = 1.505 dBm Normal
bcsiOptMonLaneTxPower.201744640.3 = 0.795 dBm Normal
bcsiOptMonLaneTxPower.201744640.4 = 1.607 dBm Normal
bcsiOptMonLaneTxPower.201752832.1 = 0.846 dBm Normal
bcsiOptMonLaneTxPower.201752832.2 = 0.242 dBm Normal
bcsiOptMonLaneTxPower.201752832.3 = 0.063 dBm Normal
bcsiOptMonLaneTxPower.201752832.4 = -0.015 dBm Normal
bcsiOptMonLaneTxPowerVal.201335168.1 = 0
bcsiOptMonLaneTxPowerVal.201343360.1 = 0
bcsiOptMonLaneTxPowerVal.201351552.1 = 592
bcsiOptMonLaneTxPowerVal.201359744.1 = 625
bcsiOptMonLaneTxPowerVal.201720192.1 = 918
bcsiOptMonLaneTxPowerVal.201728256.1 = 0
bcsiOptMonLaneTxPowerVal.201728256.2 = 0
bcsiOptMonLaneTxPowerVal.201728256.3 = 0
bcsiOptMonLaneTxPowerVal.201728256.4 = 0
bcsiOptMonLaneTxPowerVal.201736448.1 = 1292
bcsiOptMonLaneTxPowerVal.201736448.2 = 746
bcsiOptMonLaneTxPowerVal.201736448.3 = 1030
bcsiOptMonLaneTxPowerVal.201736448.4 = 838
bcsiOptMonLaneTxPowerVal.201744640.1 = 1182
bcsiOptMonLaneTxPowerVal.201744640.2 = 1414
bcsiOptMonLaneTxPowerVal.201744640.3 = 1200
bcsiOptMonLaneTxPowerVal.201744640.4 = 1447
bcsiOptMonLaneTxPowerVal.201752832.1 = 1215
bcsiOptMonLaneTxPowerVal.201752832.2 = 1057
bcsiOptMonLaneTxPowerVal.201752832.3 = 1014
bcsiOptMonLaneTxPowerVal.201752832.4 = 996
bcsiOptMonLaneRxPowerStatus.201335168.1 = notSupported
bcsiOptMonLaneRxPowerStatus.201343360.1 = notSupported
bcsiOptMonLaneRxPowerStatus.201351552.1 = normal
bcsiOptMonLaneRxPowerStatus.201359744.1 = lowWarn
bcsiOptMonLaneRxPowerStatus.201720192.1 = normal
bcsiOptMonLaneRxPowerStatus.201728256.1 = normal
bcsiOptMonLaneRxPowerStatus.201728256.2 = normal
bcsiOptMonLaneRxPowerStatus.201728256.3 = normal
bcsiOptMonLaneRxPowerStatus.201728256.4 = normal
bcsiOptMonLaneRxPowerStatus.201736448.1 = normal
bcsiOptMonLaneRxPowerStatus.201736448.2 = normal
bcsiOptMonLaneRxPowerStatus.201736448.3 = normal
bcsiOptMonLaneRxPowerStatus.201736448.4 = normal
bcsiOptMonLaneRxPowerStatus.201744640.1 = normal
bcsiOptMonLaneRxPowerStatus.201744640.2 = normal
bcsiOptMonLaneRxPowerStatus.201744640.3 = normal
bcsiOptMonLaneRxPowerStatus.201744640.4 = normal
bcsiOptMonLaneRxPowerStatus.201752832.1 = normal
bcsiOptMonLaneRxPowerStatus.201752832.2 = normal
bcsiOptMonLaneRxPowerStatus.201752832.3 = normal
bcsiOptMonLaneRxPowerStatus.201752832.4 = normal
bcsiOptMonLaneRxPower.201335168.1 = Not Supported
bcsiOptMonLaneRxPower.201343360.1 = Not Supported
bcsiOptMonLaneRxPower.201351552.1 = -1.482 dBm Normal
bcsiOptMonLaneRxPower.201359744.1 = -inf dBm Low Warning
bcsiOptMonLaneRxPower.201720192.1 = -40.000 dBm Normal
bcsiOptMonLaneRxPower.201728256.1 = -40.000 dBm Normal
bcsiOptMonLaneRxPower.201728256.2 = -40.000 dBm Normal
bcsiOptMonLaneRxPower.201728256.3 = -40.000 dBm Normal
bcsiOptMonLaneRxPower.201728256.4 = -40.000 dBm Normal
bcsiOptMonLaneRxPower.201736448.1 = -3.172 dBm Normal
bcsiOptMonLaneRxPower.201736448.2 = -3.270 dBm Normal
bcsiOptMonLaneRxPower.201736448.3 = -3.036 dBm Normal
bcsiOptMonLaneRxPower.201736448.4 = -3.271 dBm Normal
bcsiOptMonLaneRxPower.201744640.1 = -0.479 dBm Normal
bcsiOptMonLaneRxPower.201744640.2 = -1.682 dBm Normal
bcsiOptMonLaneRxPower.201744640.3 = -0.811 dBm Normal
bcsiOptMonLaneRxPower.201744640.4 = -0.783 dBm Normal
bcsiOptMonLaneRxPower.201752832.1 = -2.180 dBm Normal
bcsiOptMonLaneRxPower.201752832.2 = -2.209 dBm Normal
bcsiOptMonLaneRxPower.201752832.3 = -3.481 dBm Normal
bcsiOptMonLaneRxPower.201752832.4 = -2.800 dBm Normal
bcsiOptMonLaneRxPowerVal.201335168.1 = 0
bcsiOptMonLaneRxPowerVal.201343360.1 = 0
bcsiOptMonLaneRxPowerVal.201351552.1 = 710
bcsiOptMonLaneRxPowerVal.201359744.1 = 0
bcsiOptMonLaneRxPowerVal.201720192.1 = 0
bcsiOptMonLaneRxPowerVal.201728256.1 = 0
bcsiOptMonLaneRxPowerVal.201728256.2 = 0
bcsiOptMonLaneRxPowerVal.201728256.3 = 0
bcsiOptMonLaneRxPowerVal.201728256.4 = 0
bcsiOptMonLaneRxPowerVal.201736448.1 = 481
bcsiOptMonLaneRxPowerVal.201736448.2 = 471
bcsiOptMonLaneRxPowerVal.201736448.3 = 497
bcsiOptMonLaneRxPowerVal.201736448.4 = 470
bcsiOptMonLaneRxPowerVal.201744640.1 = 895
bcsiOptMonLaneRxPowerVal.201744640.2 = 678
bcsiOptMonLaneRxPowerVal.201744640.3 = 829
bcsiOptMonLaneRxPowerVal.201744640.4 = 835
bcsiOptMonLaneRxPowerVal.201752832.1 = 605
bcsiOptMonLaneRxPowerVal.201752832.2 = 601
bcsiOptMonLaneRxPowerVal.201752832.3 = 448
bcsiOptMonLaneRxPowerVal.201752832.4 = 524
bcsiOptMonLaneTxBiasCurrent.201335168.1 = Not Supported
bcsiOptMonLaneTxBiasCurrent.201343360.1 = Not Supported
bcsiOptMonLaneTxBiasCurrent.201351552.1 = 31.892 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201359744.1 = 35.612 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201720192.1 = 6.844 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201728256.1 = 0.000 mAmps Low Warning
bcsiOptMonLaneTxBiasCurrent.201728256.2 = 0.000 mAmps Low Warning
bcsiOptMonLaneTxBiasCurrent.201728256.3 = 0.000 mAmps Low Warning
bcsiOptMonLaneTxBiasCurrent.201728256.4 = 0.000 mAmps Low Warning
bcsiOptMonLaneTxBiasCurrent.201736448.1 = 40.086 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201736448.2 = 40.396 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201736448.3 = 39.926 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201736448.4 = 40.236 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201744640.1 = 38.886 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201744640.2 = 37.726 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201744640.3 = 39.076 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201744640.4 = 39.184 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201752832.1 = 39.856 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201752832.2 = 39.736 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201752832.3 = 39.816 mAmps Normal
bcsiOptMonLaneTxBiasCurrent.201752832.4 = 39.856 mAmps Normal
]
SNMP STATUS[TRUE]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201335168' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00028706s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61929']
SQL RUNTIME[0.00033998s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61929']
SQL RUNTIME[0.00011802s]
Linked to port 61929 via ifIndex
Sensor skipped by not numeric value: 'Not Supported', 'Ethernet 0/1 Temperature'
Perhaps this is named sensor, use discover_status() instead.
Sensor skipped by not numeric value: 'Not Supported', 'Ethernet 0/1 Tx Bias'
Perhaps this is named sensor, use discover_status() instead.
Skipped by 'exclude' event value: , Ethernet 0/1 Tx Power Status 
Skipped by 'exclude' event value: , Ethernet 0/1 Rx Power Status 

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201343360' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00021911s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61930']
SQL RUNTIME[0.00031495s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61930']
SQL RUNTIME[0.00012803s]
Linked to port 61930 via ifIndex
Sensor skipped by not numeric value: 'Not Supported', 'Ethernet 0/2 Temperature'
Perhaps this is named sensor, use discover_status() instead.
Sensor skipped by not numeric value: 'Not Supported', 'Ethernet 0/2 Tx Bias'
Perhaps this is named sensor, use discover_status() instead.
Skipped by 'exclude' event value: , Ethernet 0/2 Tx Power Status 
Skipped by 'exclude' event value: , Ethernet 0/2 Rx Power Status 

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201351552' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00019193s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61931']
SQL RUNTIME[0.00022602s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61931']
SQL RUNTIME[0.00012589s]
Linked to port 61931 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201351552.1, index: 201351552.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/3 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201351552.1')]
SQL RUNTIME[0.00123882s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201351552.1']
SQL RUNTIME[0.00112414s]
LCurrent sensor value: "30", scale: "1"
  limit_high: "46.4" -> "48"
  limit_high_warn: "" -> ""
  limit_low: "0" -> "0"
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='48' WHERE `sensor_id` = '28498']
SQL RUNTIME[0.00074482s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28498' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019598s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201351552.1, index: 201351552.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/3 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.031892, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201351552.1')]
SQL RUNTIME[0.00112081s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201351552.1']
SQL RUNTIME[0.00104499s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28499' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022697s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000592 W -> -2.2767829327708 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201351552.1, index: 201351552.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/3 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -2.2767829327708, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201351552.1')]
SQL RUNTIME[0.00125003s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201351552.1']
SQL RUNTIME[0.00111508s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28500' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027704s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201351552.1, index: 201351552.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/3 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201351552.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00041604s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201351552.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00037885s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.00071 W -> -1.4874165128092 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201351552.1, index: 201351552.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/3 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -1.4874165128092, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201351552.1')]
SQL RUNTIME[0.00107503s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201351552.1']
SQL RUNTIME[0.00106311s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28501' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00023603s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201351552.1, index: 201351552.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/3 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201351552.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031495s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201351552.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00035214s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201359744' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00017905s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61932']
SQL RUNTIME[0.00029302s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61932']
SQL RUNTIME[0.00009298s]
Linked to port 61932 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201359744.1, index: 201359744.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/4 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201359744.1')]
SQL RUNTIME[0.00116587s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201359744.1']
SQL RUNTIME[0.00104785s]
LCurrent sensor value: "30", scale: "1"
  limit_high: "46.4" -> "48"
  limit_high_warn: "" -> ""
  limit_low: "0" -> "0"
  limit_low_warn: "" -> ""


SQL[UPDATE `sensors` set `sensor_limit` ='48' WHERE `sensor_id` = '28502']
SQL RUNTIME[0.00064397s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28502' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00021791s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201359744.1, index: 201359744.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/4 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.035612, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201359744.1')]
SQL RUNTIME[0.00117493s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201359744.1']
SQL RUNTIME[0.00131297s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28503' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00186992s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000625 W -> -2.0411998265592 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201359744.1, index: 201359744.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/4 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -2.0411998265592, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201359744.1')]
SQL RUNTIME[0.00114608s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201359744.1']
SQL RUNTIME[0.00105810s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28504' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026178s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201359744.1, index: 201359744.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/4 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201359744.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00044703s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201359744.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00034904s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201359744.1, index: 201359744.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/4 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201359744.1')]
SQL RUNTIME[0.00103211s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201359744.1']
SQL RUNTIME[0.00131607s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28505' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026202s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201359744.1, index: 201359744.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/4 Rx Power Status, CURRENT: 6, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201359744.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00038505s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201359744.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00043607s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201720192' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00021601s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61976']
SQL RUNTIME[0.00027394s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61976']
SQL RUNTIME[0.00014210s]
Linked to port 61976 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201720192.1, index: 201720192.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/48 Temperature, scale: 1, limits: (, , , ), CURRENT: 27, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201720192.1')]
SQL RUNTIME[0.00072098s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201720192.1']
SQL RUNTIME[0.00125194s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26654' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020695s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201720192.1, index: 201720192.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/48 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.006844, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201720192.1')]
SQL RUNTIME[0.00066113s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201720192.1']
SQL RUNTIME[0.00122499s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26655' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019693s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000918 W -> -0.37157318798758 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201720192.1, index: 201720192.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/48 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.37157318798758, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201720192.1')]
SQL RUNTIME[0.00068784s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201720192.1']
SQL RUNTIME[0.00106502s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26656' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00033092s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201720192.1, index: 201720192.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/48 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201720192.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031996s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201720192.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00044203s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201720192.1, index: 201720192.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/48 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201720192.1')]
SQL RUNTIME[0.00068307s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201720192.1']
SQL RUNTIME[0.00101900s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26657' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00029588s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201720192.1, index: 201720192.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/48 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201720192.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00027084s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201720192.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00038290s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201728256' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00021696s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61977']
SQL RUNTIME[0.00040507s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61977']
SQL RUNTIME[0.00015402s]
Linked to port 61977 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201728256.1, index: 201728256.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/49 Lane 1 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.1')]
SQL RUNTIME[0.00062799s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.1']
SQL RUNTIME[0.00103402s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26476' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022316s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201728256.1, index: 201728256.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/49 Lane 1 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.1')]
SQL RUNTIME[0.00076509s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.1']
SQL RUNTIME[0.00126410s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26477' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024891s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201728256.1, index: 201728256.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/49 Lane 1 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.1')]
SQL RUNTIME[0.00074100s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.1']
SQL RUNTIME[0.00103092s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26478' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025582s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201728256.1, index: 201728256.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 1 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00035715s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041986s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201728256.1, index: 201728256.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/49 Lane 1 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.1')]
SQL RUNTIME[0.00064492s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.1']
SQL RUNTIME[0.00097990s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26479' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026917s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201728256.1, index: 201728256.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 1 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037098s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00053000s]
.Linked to port 61977 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201728256.2, index: 201728256.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/49 Lane 2 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.2')]
SQL RUNTIME[0.00094295s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.2']
SQL RUNTIME[0.00174403s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26480' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024199s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201728256.2, index: 201728256.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/49 Lane 2 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.2')]
SQL RUNTIME[0.00104284s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.2']
SQL RUNTIME[0.00132203s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26481' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022292s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201728256.2, index: 201728256.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/49 Lane 2 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.2')]
SQL RUNTIME[0.00094104s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.2']
SQL RUNTIME[0.00102592s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26482' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00038695s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201728256.2, index: 201728256.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 2 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00052500s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00040197s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201728256.2, index: 201728256.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/49 Lane 2 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.2')]
SQL RUNTIME[0.00061893s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.2']
SQL RUNTIME[0.00109386s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26483' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024486s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201728256.2, index: 201728256.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 2 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037384s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00050497s]
.Linked to port 61977 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201728256.3, index: 201728256.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/49 Lane 3 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.3')]
SQL RUNTIME[0.00063419s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.3']
SQL RUNTIME[0.00130606s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26484' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022101s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201728256.3, index: 201728256.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/49 Lane 3 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.3')]
SQL RUNTIME[0.00063300s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.3']
SQL RUNTIME[0.00104594s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26485' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022006s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201728256.3, index: 201728256.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/49 Lane 3 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.3')]
SQL RUNTIME[0.00067306s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.3']
SQL RUNTIME[0.00101590s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26486' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025797s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201728256.3, index: 201728256.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 3 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00044298s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00040603s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201728256.3, index: 201728256.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/49 Lane 3 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.3')]
SQL RUNTIME[0.00060511s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.3']
SQL RUNTIME[0.00104904s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26487' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00038290s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201728256.3, index: 201728256.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 3 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00069404s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00058508s]
.Linked to port 61977 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201728256.4, index: 201728256.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/49 Lane 4 Temperature, scale: 1, limits: (, , , ), CURRENT: 30, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.4')]
SQL RUNTIME[0.00074911s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201728256.4']
SQL RUNTIME[0.00128603s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26488' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00053000s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201728256.4, index: 201728256.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/49 Lane 4 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.4')]
SQL RUNTIME[0.00096512s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201728256.4']
SQL RUNTIME[0.00116706s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26489' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028801s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201728256.4, index: 201728256.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/49 Lane 4 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.4')]
SQL RUNTIME[0.00099015s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201728256.4']
SQL RUNTIME[0.00173497s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26490' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027299s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201728256.4, index: 201728256.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 4 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00041604s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00059390s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0 W -> -99 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201728256.4, index: 201728256.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/49 Lane 4 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -99, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.4')]
SQL RUNTIME[0.00064397s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201728256.4']
SQL RUNTIME[0.00096917s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '26491' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024581s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201728256.4, index: 201728256.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/49 Lane 4 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026512s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201728256.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00062490s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201736448' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00019002s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61978']
SQL RUNTIME[0.00048018s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61978']
SQL RUNTIME[0.00018787s]
Linked to port 61978 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201736448.1, index: 201736448.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/50 Lane 1 Temperature, scale: 1, limits: (, , , ), CURRENT: 39, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.1')]
SQL RUNTIME[0.00113392s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.1']
SQL RUNTIME[0.00098586s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28029' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022292s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201736448.1, index: 201736448.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/50 Lane 1 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.040086, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.1')]
SQL RUNTIME[0.00082088s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.1']
SQL RUNTIME[0.00107503s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28030' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00040293s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001292 W -> 1.1126251365907 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201736448.1, index: 201736448.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/50 Lane 1 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 1.1126251365907, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.1')]
SQL RUNTIME[0.00094295s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.1']
SQL RUNTIME[0.00101805s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28031' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025296s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201736448.1, index: 201736448.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 1 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00063396s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041294s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000481 W -> -3.1785492362617 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201736448.1, index: 201736448.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/50 Lane 1 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -3.1785492362617, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.1')]
SQL RUNTIME[0.00587821s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.1']
SQL RUNTIME[0.00154305s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28032' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024509s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201736448.1, index: 201736448.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 1 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037098s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041199s]
.Linked to port 61978 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201736448.2, index: 201736448.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/50 Lane 2 Temperature, scale: 1, limits: (, , , ), CURRENT: 39, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.2')]
SQL RUNTIME[0.00103688s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.2']
SQL RUNTIME[0.00112200s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28033' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026608s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201736448.2, index: 201736448.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/50 Lane 2 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.040396, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.2')]
SQL RUNTIME[0.00098395s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.2']
SQL RUNTIME[0.00120521s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28034' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027704s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000746 W -> -1.2726117252733 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201736448.2, index: 201736448.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/50 Lane 2 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -1.2726117252733, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.2')]
SQL RUNTIME[0.00153399s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.2']
SQL RUNTIME[0.00188017s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28035' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024891s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201736448.2, index: 201736448.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 2 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00057793s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00057197s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000471 W -> -3.269790928711 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201736448.2, index: 201736448.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/50 Lane 2 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -3.269790928711, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.2')]
SQL RUNTIME[0.00144291s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.2']
SQL RUNTIME[0.00140500s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28036' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00021911s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201736448.2, index: 201736448.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 2 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031710s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041604s]
.Linked to port 61978 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201736448.3, index: 201736448.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/50 Lane 3 Temperature, scale: 1, limits: (, , , ), CURRENT: 39, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.3')]
SQL RUNTIME[0.00100398s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.3']
SQL RUNTIME[0.00108194s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28037' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00029802s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201736448.3, index: 201736448.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/50 Lane 3 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039926, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.3')]
SQL RUNTIME[0.00097585s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.3']
SQL RUNTIME[0.00111604s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28038' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022912s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.00103 W -> 0.12837224705172 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201736448.3, index: 201736448.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/50 Lane 3 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.12837224705172, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.3')]
SQL RUNTIME[0.00105715s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.3']
SQL RUNTIME[0.00139213s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28039' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00029397s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201736448.3, index: 201736448.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 3 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00035310s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00047112s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000497 W -> -3.0364361126667 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201736448.3, index: 201736448.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/50 Lane 3 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -3.0364361126667, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.3')]
SQL RUNTIME[0.00082207s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.3']
SQL RUNTIME[0.00098610s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28040' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020099s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201736448.3, index: 201736448.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 3 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00033689s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00038910s]
.Linked to port 61978 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201736448.4, index: 201736448.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/50 Lane 4 Temperature, scale: 1, limits: (, , , ), CURRENT: 39, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.4')]
SQL RUNTIME[0.00092506s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201736448.4']
SQL RUNTIME[0.00101709s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28041' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022078s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201736448.4, index: 201736448.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/50 Lane 4 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.040236, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.4')]
SQL RUNTIME[0.00095797s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201736448.4']
SQL RUNTIME[0.00113797s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28042' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00023890s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000838 W -> -0.76755981369724 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201736448.4, index: 201736448.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/50 Lane 4 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.76755981369724, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.4')]
SQL RUNTIME[0.00090408s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201736448.4']
SQL RUNTIME[0.00104499s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28043' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019693s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201736448.4, index: 201736448.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 4 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00033116s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00035501s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.00047 W -> -3.2790214206428 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201736448.4, index: 201736448.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/50 Lane 4 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -3.2790214206428, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.4')]
SQL RUNTIME[0.00089884s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201736448.4']
SQL RUNTIME[0.00109410s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28044' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024009s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201736448.4, index: 201736448.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/50 Lane 4 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00028300s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201736448.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00032187s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201744640' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00019789s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61979']
SQL RUNTIME[0.00027609s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61979']
SQL RUNTIME[0.00010610s]
Linked to port 61979 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201744640.1, index: 201744640.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/51 Lane 1 Temperature, scale: 1, limits: (, , , ), CURRENT: 36, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.1')]
SQL RUNTIME[0.00081587s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.1']
SQL RUNTIME[0.00100493s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28045' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025606s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201744640.1, index: 201744640.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/51 Lane 1 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.038886, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.1')]
SQL RUNTIME[0.00108004s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.1']
SQL RUNTIME[0.00107098s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28046' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022101s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001182 W -> 0.72617476545236 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201744640.1, index: 201744640.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/51 Lane 1 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.72617476545236, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.1')]
SQL RUNTIME[0.00086308s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.1']
SQL RUNTIME[0.00100994s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28047' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019789s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201744640.1, index: 201744640.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 1 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025702s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00038218s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000895 W -> -0.48176964684088 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201744640.1, index: 201744640.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/51 Lane 1 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.48176964684088, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.1')]
SQL RUNTIME[0.00080991s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.1']
SQL RUNTIME[0.00100303s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28048' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00021410s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201744640.1, index: 201744640.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 1 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00029707s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00034523s]
.Linked to port 61979 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201744640.2, index: 201744640.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/51 Lane 2 Temperature, scale: 1, limits: (, , , ), CURRENT: 36, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.2')]
SQL RUNTIME[0.00091004s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.2']
SQL RUNTIME[0.00096703s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28049' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00261998s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201744640.2, index: 201744640.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/51 Lane 2 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.037726, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.2')]
SQL RUNTIME[0.00084114s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.2']
SQL RUNTIME[0.00101805s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28050' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00018382s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001414 W -> 1.5044940946088 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201744640.2, index: 201744640.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/51 Lane 2 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 1.5044940946088, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.2')]
SQL RUNTIME[0.00089693s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.2']
SQL RUNTIME[0.00114584s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28051' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00023317s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201744640.2, index: 201744640.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 2 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00038815s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00052500s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000678 W -> -1.6877030613294 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201744640.2, index: 201744640.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/51 Lane 2 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -1.6877030613294, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.2')]
SQL RUNTIME[0.00079989s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.2']
SQL RUNTIME[0.00098991s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28052' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00017285s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201744640.2, index: 201744640.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 2 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026798s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00032616s]
.Linked to port 61979 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201744640.3, index: 201744640.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/51 Lane 3 Temperature, scale: 1, limits: (, , , ), CURRENT: 36, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.3')]
SQL RUNTIME[0.00108385s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.3']
SQL RUNTIME[0.00102901s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28053' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00018811s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201744640.3, index: 201744640.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/51 Lane 3 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039076, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.3')]
SQL RUNTIME[0.00089312s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.3']
SQL RUNTIME[0.00095797s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28054' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00016499s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.0012 W -> 0.79181246047625 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201744640.3, index: 201744640.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/51 Lane 3 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.79181246047625, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.3')]
SQL RUNTIME[0.00091386s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.3']
SQL RUNTIME[0.00099921s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28055' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00022388s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201744640.3, index: 201744640.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 3 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00030994s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00032091s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000829 W -> -0.81445469449726 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201744640.3, index: 201744640.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/51 Lane 3 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.81445469449726, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.3')]
SQL RUNTIME[0.00095916s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.3']
SQL RUNTIME[0.00153518s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28056' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00020814s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201744640.3, index: 201744640.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 3 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031304s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00044894s]
.Linked to port 61979 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201744640.4, index: 201744640.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/51 Lane 4 Temperature, scale: 1, limits: (, , , ), CURRENT: 36, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.4')]
SQL RUNTIME[0.00090790s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201744640.4']
SQL RUNTIME[0.00112700s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28057' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00016713s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201744640.4, index: 201744640.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/51 Lane 4 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039184, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.4')]
SQL RUNTIME[0.00102711s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201744640.4']
SQL RUNTIME[0.00111079s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28058' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00018215s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001447 W -> 1.6046853111904 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201744640.4, index: 201744640.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/51 Lane 4 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 1.6046853111904, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.4')]
SQL RUNTIME[0.00099993s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201744640.4']
SQL RUNTIME[0.00104499s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28059' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00042892s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201744640.4, index: 201744640.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 4 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00046492s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00036502s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000835 W -> -0.78313524516398 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201744640.4, index: 201744640.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/51 Lane 4 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.78313524516398, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.4')]
SQL RUNTIME[0.00228000s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201744640.4']
SQL RUNTIME[0.00284195s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28060' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00032091s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201744640.4, index: 201744640.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/51 Lane 4 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00055790s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201744640.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00079894s]
.
SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '716' AND `ifIndex` = '201752832' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00035381s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '61980']
SQL RUNTIME[0.00046706s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '61980']
SQL RUNTIME[0.00013590s]
Linked to port 61980 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201752832.1, index: 201752832.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/52 Lane 1 Temperature, scale: 1, limits: (, , , ), CURRENT: 38, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.1')]
SQL RUNTIME[0.00173903s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.1']
SQL RUNTIME[0.00163102s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28061' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00035405s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201752832.1, index: 201752832.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/52 Lane 1 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039856, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.1')]
SQL RUNTIME[0.00227380s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.1']
SQL RUNTIME[0.00149083s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28062' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00034094s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001215 W -> 0.84576277934331 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201752832.1, index: 201752832.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/52 Lane 1 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.84576277934331, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.1')]
SQL RUNTIME[0.00130105s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.1']
SQL RUNTIME[0.00157309s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28063' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00033498s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201752832.1, index: 201752832.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 1 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00069809s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00067186s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000605 W -> -2.1824462534753 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201752832.1, index: 201752832.1, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/52 Lane 1 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -2.1824462534753, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.1')]
SQL RUNTIME[0.00132799s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.1']
SQL RUNTIME[0.00153089s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28064' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00035000s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201752832.1, index: 201752832.1, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 1 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00050306s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00057483s]
.Linked to port 61980 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201752832.2, index: 201752832.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/52 Lane 2 Temperature, scale: 1, limits: (, , , ), CURRENT: 38, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.2')]
SQL RUNTIME[0.00142908s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.2']
SQL RUNTIME[0.00130010s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28065' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00031996s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201752832.2, index: 201752832.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/52 Lane 2 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039736, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.2')]
SQL RUNTIME[0.00143194s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.2']
SQL RUNTIME[0.00163794s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28066' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00030303s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001057 W -> 0.24074987307426 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201752832.2, index: 201752832.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/52 Lane 2 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.24074987307426, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.2')]
SQL RUNTIME[0.00143695s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.2']
SQL RUNTIME[0.00117302s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28067' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00027299s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201752832.2, index: 201752832.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 2 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037503s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041699s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000601 W -> -2.2112552799726 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201752832.2, index: 201752832.2, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/52 Lane 2 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -2.2112552799726, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.2')]
SQL RUNTIME[0.00090909s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.2']
SQL RUNTIME[0.00170398s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28068' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028992s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201752832.2, index: 201752832.2, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 2 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00049186s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00059390s]
.Linked to port 61980 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201752832.3, index: 201752832.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/52 Lane 3 Temperature, scale: 1, limits: (, , , ), CURRENT: 38, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.3')]
SQL RUNTIME[0.00116611s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.3']
SQL RUNTIME[0.00138092s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28069' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00024319s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201752832.3, index: 201752832.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/52 Lane 3 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039816, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.3')]
SQL RUNTIME[0.00111008s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.3']
SQL RUNTIME[0.00128007s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28070' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028110s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.001014 W -> 0.060379549973174 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201752832.3, index: 201752832.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/52 Lane 3 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: 0.060379549973174, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.3')]
SQL RUNTIME[0.00095892s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.3']
SQL RUNTIME[0.00113201s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28071' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00025606s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201752832.3, index: 201752832.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 3 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00032806s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00044894s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000448 W -> -3.4872198600186 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201752832.3, index: 201752832.3, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/52 Lane 3 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -3.4872198600186, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.3')]
SQL RUNTIME[0.00089288s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.3']
SQL RUNTIME[0.00118208s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28072' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00030494s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201752832.3, index: 201752832.3, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 3 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037098s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00222588s]
.Linked to port 61980 via ifIndex
Discover sensor: [class: temperature, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.2.201752832.4, index: 201752832.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature, descr: Ethernet 0/52 Lane 4 Temperature, scale: 1, limits: (, , , ), CURRENT: 38, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.4')]
SQL RUNTIME[0.00125504s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTemperature' AND `sensor_index` = '201752832.4']
SQL RUNTIME[0.00112009s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28073' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026107s]
.Discover sensor: [class: current, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.9.201752832.4, index: 201752832.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent, descr: Ethernet 0/52 Lane 4 Tx Bias, scale: 0.001, limits: (, , , ), CURRENT: 0.039856, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.4')]
SQL RUNTIME[0.00141788s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxBiasCurrent' AND `sensor_index` = '201752832.4']
SQL RUNTIME[0.00164795s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28074' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00030613s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000996 W -> -0.017406615763012 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.5.201752832.4, index: 201752832.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal, descr: Ethernet 0/52 Lane 4 Tx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -0.017406615763012, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.4')]
SQL RUNTIME[0.00123000s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneTxPowerVal' AND `sensor_index` = '201752832.4']
SQL RUNTIME[0.00120211s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28075' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00026202s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.3.201752832.4, index: 201752832.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 4 Tx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00043106s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneTxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00036907s]
.DOM power sensor forced to dBm sensor.
Converted DBM value: 0.000524 W -> -2.8066871301627 dBm
Discover sensor: [class: dbm, device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.8.201752832.4, index: 201752832.4, type: BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal, descr: Ethernet 0/52 Lane 4 Rx Power, scale: 1.0E-6, limits: (, , , ), CURRENT: -2.8066871301627, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.4')]
SQL RUNTIME[0.00138998s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '716' AND `sensor_type` = 'BROCADE-OPTICAL-MONITORING-MIB-bcsiOptMonLaneRxPowerVal' AND `sensor_index` = '201752832.4']
SQL RUNTIME[0.00146985s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '28076' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00029492s]
.Discover status: [device: slx9140, oid: .1.3.6.1.4.1.1588.3.1.8.1.1.1.6.201752832.4, index: 201752832.4, type: bcsiOptMonPowerStatus, descr: Ethernet 0/52 Lane 4 Rx Power Status, CURRENT: 5, , ]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00035286s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `status_mib` = 'BROCADE-OPTICAL-MONITORING-MIB' AND `status_object` = 'bcsiOptMonLaneRxPowerStatus' AND `status_type` = 'bcsiOptMonPowerStatus' AND `status_index` = '201752832.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00041509s]
.
 o ENTITY-SENSOR-MIB    
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.1664s]
STDOUT[
entPhySensorValue = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00087190s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00028515s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00157595s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030184s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00024104s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00155997s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00067687s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00077200s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00026989s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00034881s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029802s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00038385s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00041699s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00043392s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035191s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00070810s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00021982s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00020599s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00034904s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00021696s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00022912s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00025797s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035596s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00038505s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00019693s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00017905s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00017500s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00021291s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '716' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00021696s]

SQL[SELECT * FROM `status` WHERE `device_id` = '716' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00224900s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '716' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00025916s]


 o Duration             2.536s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_storage']
SQL RUNTIME[0.00023103s]
#####  Module Start: storage  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' dskEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0442s]
STDOUT[
dskEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `storage` WHERE `device_id` = '716']
SQL RUNTIME[0.00019503s]

 o Duration             0.0477s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_neighbours']
SQL RUNTIME[0.00037479s]
#####  Module Start: neighbours  #####

 o LLDP-MIB             
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' lldpRemChassisIdSubtype]

CMD EXITCODE[0]
CMD RUNTIME[0.0315s]
STDOUT[
lldpRemChassisIdSubtype = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `neighbours` WHERE `device_id` = '716']
SQL RUNTIME[0.00040793s]



 o Duration             0.0355s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_arp-table']
SQL RUNTIME[0.00031209s]
#####  Module Start: arp-table  #####


SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '716' GROUP BY `port_id`]
SQL RUNTIME[0.00050092s]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' ipNetToPhysicalPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.051s]
STDOUT[
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.20"] 2:4:96:9c:3b:5c
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.21"] 2:4:96:9c:82:40
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.25"] fc:a:81:f8:ad:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.27"] d8:84:66:67:f9:84
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.28"] 6c:8b:d3:6c:be:c7
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.35"] 2:4:96:af:5f:c0
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.36"] 2:4:96:af:66:fa
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.48"] 7c:21:e:38:81:bf
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.49"] 7c:21:e:38:83:db
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.50"] 70:61:7b:ea:af:83
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.53"] 2:4:96:a0:cf:3a
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.57"] 2:80:f4:7f:89:40
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.61"] 68:3b:78:ed:5d:c7
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.73"] fc:a:81:f8:ab:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.74"] fc:a:81:f8:a9:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.88"] 0:4:96:b7:cc:ed
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.89"] 0:4:96:b7:d6:11
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.96"] 0:8c:10:1d:c6:9f
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.97"] 0:4:96:a5:2:42
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.98"] 0:4:96:a2:f5:f0
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.99"] 0:0:5e:0:1:2
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.101"] fc:a:81:f8:aa:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.103"] 0:4:96:b7:dd:73
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.152"] 0:b1:e3:eb:4d:c7
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.159"] 0:4:96:b7:d4:a9
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.164"] 0:b8:b3:a2:b6:c7
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.169"] 0:b8:b3:87:7b:c7
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.204"] 60:9c:9f:ec:e6:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.205"] 0:4:96:b7:ed:45
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.214"] fc:a:81:f8:b8:1
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.243"] 0:4:96:97:a6:77
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.244"] 0:8c:10:b7:79:50
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.246"] 0:8c:10:1e:a0:87
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.248"] 2:4:96:9c:2a:18
ipNetToPhysicalPhysAddress[1207959553][ipv4]["160.103.1.249"] 2:4:96:9c:2f:2c
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToPhysicalPhysAddress

SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M
          LEFT JOIN ports AS I ON M.port_id = I.port_id
          WHERE I.device_id = '716']
SQL RUNTIME[0.00071788s]
...................................

 o Duration             0.057s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_junose-atm-vp']
SQL RUNTIME[0.00032806s]
#####  Module Start: junose-atm-vp  #####


 o Duration             0.0006s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_bgp-peers']
SQL RUNTIME[0.00026298s]
#####  Module Start: bgp-peers  #####


CMD[/usr/bin/snmpget -t '5' -v2c -c *** -Pud -OQUv -m BGP4-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' bgpLocalAs.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0095s]
STDOUT[
No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
No BGP on host
SQL[SELECT * FROM `bgpPeers` WHERE `device_id` = '716']
SQL RUNTIME[0.00065517s]

 o Duration             0.0138s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_mac-accounting']
SQL RUNTIME[0.00030613s]
#####  Module Start: mac-accounting  #####


 o Duration             0.0004s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_sla']
SQL RUNTIME[0.00027299s]
#####  Module Start: sla  #####

 o DISMAN-PING-MIB      
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' pingCtlEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.1978s]
STDOUT[
pingCtlEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `slas` WHERE `device_id` = '716']
SQL RUNTIME[0.00035000s]

 o Duration             0.2016s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_lsp']
SQL RUNTIME[0.00032091s]
Module [lsp] disabled globally by config in process [discovery].

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_pseudowires']
SQL RUNTIME[0.00027704s]
#####  Module Start: pseudowires  #####


SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '716']
SQL RUNTIME[0.00027204s]
 o PW-STD-MIB           
CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' pwID]

CMD EXITCODE[0]
CMD RUNTIME[0.0216s]
STDOUT[
pwID = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


 o Duration             0.0256s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_virtual-machines']
SQL RUNTIME[0.00031710s]
#####  Module Start: virtual-machines  #####



 o Duration             0.0004s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_cisco-cbqos']
SQL RUNTIME[0.00023508s]
#####  Module Start: cisco-cbqos  #####


SQL[SELECT * FROM `ports_cbqos` WHERE `device_id` = '716']
SQL RUNTIME[0.00022697s]

CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m CISCO-CLASS-BASED-QOS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'slx9140':'161' cbQosIfType]

CMD EXITCODE[0]
CMD RUNTIME[0.1706s]
STDOUT[
cbQosIfType = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
QoS not configured.

 o Duration             0.1734s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_ucd-diskio']
SQL RUNTIME[0.00029016s]
#####  Module Start: ucd-diskio  #####


CMD[/usr/bin/snmpbulkwalk -t '5' -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'slx9140':'161' diskIOEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.043s]
STDOUT[
diskIOEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '716']
SQL RUNTIME[0.00043297s]


 o Duration             0.0467s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_wifi']
SQL RUNTIME[0.00035906s]
#####  Module Start: wifi  #####


SQL[SELECT * FROM `wifi_radios` WHERE `device_id` = '716']
SQL RUNTIME[0.00032783s]

SQL[SELECT * FROM `wifi_wlans` WHERE `device_id` = '716']
SQL RUNTIME[0.00033808s]

SQL[SELECT * FROM `wifi_aps` WHERE `device_id` = '716']
SQL RUNTIME[0.00118899s]


 o Duration             0.0032s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_p2p-radios']
SQL RUNTIME[0.00037313s]
#####  Module Start: p2p-radios  #####


 o Duration             0.0002s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_graphs']
SQL RUNTIME[0.00033188s]
#####  Module Start: graphs  #####


 o Duration             0.0005s


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '716' AND `attrib_type` = 'discover_raid']
SQL RUNTIME[0.00025392s]
Module [raid] disabled globally by config in process [discovery].
 o Modules Disabled     lsp, raid
 o Modules Enabled      os, mibs, ports, ports-stack, vlans, oids, cisco-vrf, ip-addresses, processors, mempools, inventory, printersupplies, 
                        sensors,storage, neighbours, arp-table, junose-atm-vp, bgp-peers, mac-accounting, sla, pseudowires, virtual-machines, 
                        cisco-cbqos,ucd-diskio, wifi, p2p-radios, graphs 

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '716';]
SQL RUNTIME[0.00025487s]

SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='network',`last_discovered_timetaken` ='24.1362',`force_discovery` ='0',`device_state` ='a:5:{s:15:\"poller_mod_perf\";a:28:{s:6:\"system\";d:0.1062;s:2:\"os\";d:0.0011000000000000001;s:7:\"sensors\";d:18.622199999999999;s:6:\"status\";d:1.6087;s:7:\"counter\";d:0.00080000000000000004;s:10:\"processors\";d:0.47689999999999999;s:8:\"mempools\";d:0.47470000000000001;s:7:\"storage\";d:0.00080000000000000004;s:8:\"netstats\";d:0.23719999999999999;s:7:\"ucd-mib\";d:0.061899999999999997;s:13:\"ipSystemStats\";d:0.044499999999999998;s:5:\"ports\";d:3.8100999999999998;s:9:\"bgp-peers\";d:0.020899999999999998;s:15:\"printersupplies\";d:0.00050000000000000001;s:10:\"ucd-diskio\";d:0.00059999999999999995;s:4:\"wifi\";d:0.0019;s:10:\"p2p-radios\";d:0.00080000000000000004;s:4:\"ospf\";d:0.00040000000000000002;s:3:\"sla\";d:0.00080000000000000004;s:11:\"pseudowires\";d:0.00069999999999999999;s:14:\"mac-accounting\";d:0.00069999999999999999;s:12:\"loadbalancer\";d:0.00020000000000000001;s:15:\"entity-physical\";d:0.0001;s:12:\"applications\";d:0.00059999999999999995;s:9:\"fdb-table\";d:0.0011000000000000001;s:6:\"graphs\";d:0.00020000000000000001;s:4:\"oids\";d:0.00029999999999999997;s:6:\"probes\";d:0.00029999999999999997;}s:17:\"poller_ports_perf\";a:1:{s:4:\"vlan\";d:0.052115917205810547;}s:14:\"poller_history\";a:288:{i:1600686717;d:25.549399999999999;i:1600686417;d:25.666399999999999;i:1600686110;d:25.609500000000001;i:1600685810;d:26.029900000000001;i:1600685520;d:25.688600000000001;i:1600685220;d:25.1555;i:1600684914;d:25.589200000000002;i:1600684607;d:25.107900000000001;i:1600684313;d:26.312000000000001;i:1600684011;d:25.630400000000002;i:1600683719;d:25.723199999999999;i:1600683409;d:25.397400000000001;i:1600683119;d:25.575500000000002;i:1600682812;d:25.683;i:1600682518;d:25.6067;i:1600682216;d:25.2103;i:1600681922;d:25.257999999999999;i:1600681616;d:25.142700000000001;i:1600681312;d:25.850999999999999;i:1600681014;d:25.7225;i:1600680714;d:25.343599999999999;i:1600680422;d:25.566800000000001;i:1600680128;d:25.278099999999998;i:1600679814;d:25.529299999999999;i:1600679520;d:25.410499999999999;i:1600679189;d:25.3628;i:1600678803;d:29.132400000000001;i:1600678615;d:46.155000000000001;i:1600678333;d:25.547499999999999;i:1600678016;d:25.265000000000001;i:1600677716;d:25.698699999999999;i:1600677417;d:25.249099999999999;i:1600677115;d:25.535299999999999;i:1600676814;d:25.482500000000002;i:1600676522;d:25.505800000000001;i:1600676210;d:25.2821;i:1600675915;d:25.6935;i:1600675613;d:25.945699999999999;i:1600675323;d:25.5413;i:1600675016;d:25.527699999999999;i:1600674726;d:25.290700000000001;i:1600674414;d:25.285900000000002;i:1600674110;d:25.955400000000001;i:1600673815;d:25.609500000000001;i:1600673519;d:25.328099999999999;i:1600673216;d:24.981400000000001;i:1600672905;d:25.4724;i:1600672615;d:25.518999999999998;i:1600672315;d:25.357099999999999;i:1600672013;d:25.531099999999999;i:1600671715;d:25.370100000000001;i:1600671415;d:25.683;i:1600671108;d:25.500399999999999;i:1600670815;d:26.0459;i:1600670516;d:25.383400000000002;i:1600670210;d:25.4861;i:1600669917;d:25.146799999999999;i:1600669613;d:25.316099999999999;i:1600669316;d:25.210699999999999;i:1600669012;d:25.612500000000001;i:1600668712;d:25.408200000000001;i:1600668412;d:25.9754;i:1600668112;d:25.248899999999999;i:1600667816;d:25.258500000000002;i:1600667506;d:25.400099999999998;i:1600667206;d:25.882400000000001;i:1600666906;d:25.9221;i:1600666613;d:26.225300000000001;i:1600666316;d:25.7119;i:1600666011;d:25.302199999999999;i:1600665713;d:25.4026;i:1600665410;d:25.074999999999999;i:1600665106;d:25.698499999999999;i:1600664808;d:25.540299999999998;i:1600664506;d:25.402999999999999;i:1600664210;d:25.470400000000001;i:1600663910;d:25.802399999999999;i:1600663608;d:25.743400000000001;i:1600663310;d:26.0457;i:1600663008;d:25.020900000000001;i:1600662705;d:25.410499999999999;i:1600662410;d:25.430800000000001;i:1600662104;d:26.0794;i:1600661808;d:25.702999999999999;i:1600661508;d:25.604600000000001;i:1600661203;d:25.7925;i:1600660908;d:25.7531;i:1600660609;d:25.433399999999999;i:1600660307;d:25.441199999999998;i:1600660006;d:25.544599999999999;i:1600659709;d:25.943100000000001;i:1600659406;d:25.537500000000001;i:1600659106;d:25.591799999999999;i:1600658807;d:25.340900000000001;i:1600658507;d:25.549099999999999;i:1600658207;d:25.310199999999998;i:1600657906;d:25.577999999999999;i:1600657605;d:25.321300000000001;i:1600657310;d:25.245200000000001;i:1600657007;d:25.4938;i:1600656703;d:25.506900000000002;i:1600656412;d:25.3628;i:1600656112;d:25.525600000000001;i:1600655809;d:25.470500000000001;i:1600655509;d:25.498699999999999;i:1600655208;d:25.6282;i:1600654911;d:25.476500000000001;i:1600654606;d:25.731100000000001;i:1600654308;d:25.8748;i:1600654009;d:25.279299999999999;i:1600653710;d:26.317599999999999;i:1600653407;d:25.393599999999999;i:1600653111;d:25.762699999999999;i:1600652810;d:25.602;i:1600652509;d:25.584099999999999;i:1600652207;d:25.602;i:1600651910;d:25.793299999999999;i:1600651606;d:25.493500000000001;i:1600651308;d:26.3706;i:1600651005;d:25.8674;i:1600650713;d:26.105;i:1600650416;d:25.523299999999999;i:1600650108;d:25.3262;i:1600649811;d:25.6751;i:1600649505;d:25.235700000000001;i:1600649208;d:25.8842;i:1600648910;d:25.591699999999999;i:1600648610;d:25.5822;i:1600648307;d:25.674099999999999;i:1600648009;d:25.346800000000002;i:1600647709;d:25.681100000000001;i:1600647409;d:26.068999999999999;i:1600647113;d:25.743600000000001;i:1600646807;d:26.140000000000001;i:1600646505;d:26.2606;i:1600646211;d:25.684699999999999;i:1600645908;d:25.296800000000001;i:1600645603;d:25.540800000000001;i:1600645313;d:26.1936;i:1600645001;d:25.355799999999999;i:1600644709;d:25.917200000000001;i:1600644405;d:25.59;i:1600644108;d:25.699400000000001;i:1600643815;d:25.636500000000002;i:1600643507;d:25.557099999999998;i:1600643216;d:25.599699999999999;i:1600642912;d:25.755800000000001;i:1600642604;d:25.224699999999999;i:1600642309;d:25.696899999999999;i:1600642008;d:25.399899999999999;i:1600641713;d:25.802900000000001;i:1600641417;d:24.890799999999999;i:1600641109;d:25.515799999999999;i:1600640808;d:25.394600000000001;i:1600640512;d:25.540299999999998;i:1600640208;d:25.683700000000002;i:1600639909;d:25.8858;i:1600639609;d:25.6693;i:1600639309;d:25.871300000000002;i:1600639003;d:25.848500000000001;i:1600638709;d:25.9161;i:1600638404;d:25.268999999999998;i:1600638108;d:25.887499999999999;i:1600637808;d:25.872299999999999;i:1600637507;d:25.540500000000002;i:1600637209;d:25.232099999999999;i:1600636911;d:25.6752;i:1600636616;d:25.378499999999999;i:1600636309;d:25.8142;i:1600636008;d:25.752600000000001;i:1600635707;d:25.667999999999999;i:1600635408;d:25.538599999999999;i:1600635112;d:25.362300000000001;i:1600634787;d:25.528199999999998;i:1600634507;d:29.2942;i:1600634213;d:25.587499999999999;i:1600633905;d:25.798999999999999;i:1600633603;d:25.840699999999998;i:1600633308;d:25.949300000000001;i:1600633006;d:25.629999999999999;i:1600632714;d:25.790800000000001;i:1600632408;d:25.486699999999999;i:1600632106;d:26.042000000000002;i:1600631810;d:25.508400000000002;i:1600631506;d:28.447399999999998;i:1600631203;d:25.652100000000001;i:1600630906;d:25.3935;i:1600630608;d:25.5168;i:1600630306;d:25.4954;i:1600630011;d:25.451599999999999;i:1600629704;d:25.566099999999999;i:1600629407;d:25.539300000000001;i:1600629112;d:25.658200000000001;i:1600628804;d:25.634399999999999;i:1600628505;d:25.9086;i:1600628208;d:25.479299999999999;i:1600627908;d:25.469100000000001;i:1600627607;d:25.366199999999999;i:1600627306;d:25.6647;i:1600627004;d:25.6892;i:1600626707;d:25.479299999999999;i:1600626411;d:25.7773;i:1600626104;d:26.1142;i:1600625808;d:25.8447;i:1600625507;d:25.382899999999999;i:1600625208;d:25.897400000000001;i:1600624908;d:25.6676;i:1600624611;d:25.6953;i:1600624308;d:25.188600000000001;i:1600624007;d:25.225000000000001;i:1600623672;d:25.677399999999999;i:1600623412;d:32.967199999999998;i:1600623109;d:25.6251;i:1600622811;d:25.7258;i:1600622508;d:25.6341;i:1600622210;d:25.6813;i:1600621908;d:25.833600000000001;i:1600621613;d:25.7195;i:1600621306;d:25.493600000000001;i:1600621010;d:26.239999999999998;i:1600620715;d:25.305499999999999;i:1600620411;d:25.377199999999998;i:1600620108;d:25.630299999999998;i:1600619801;d:25.661300000000001;i:1600619508;d:25.721;i:1600619207;d:25.440300000000001;i:1600618905;d:25.752700000000001;i:1600618612;d:25.3004;i:1600618315;d:25.785;i:1600618009;d:25.786899999999999;i:1600617711;d:25.498999999999999;i:1600617406;d:25.642700000000001;i:1600617106;d:25.519200000000001;i:1600616806;d:25.880299999999998;i:1600616506;d:25.824300000000001;i:1600616210;d:25.569500000000001;i:1600615907;d:25.690300000000001;i:1600615610;d:25.770800000000001;i:1600615312;d:25.878399999999999;i:1600615009;d:25.436499999999999;i:1600614707;d:25.466200000000001;i:1600614411;d:25.351500000000001;i:1600614105;d:25.545300000000001;i:1600613808;d:25.725200000000001;i:1600613506;d:25.5136;i:1600613204;d:25.513400000000001;i:1600612906;d:25.432700000000001;i:1600612605;d:25.5472;i:1600612304;d:25.6113;i:1600612004;d:25.272300000000001;i:1600611708;d:25.588799999999999;i:1600611416;d:25.7849;i:1600611103;d:25.5;i:1600610815;d:26.062999999999999;i:1600610506;d:25.667999999999999;i:1600610206;d:25.6417;i:1600609904;d:25.607399999999998;i:1600609609;d:25.986999999999998;i:1600609300;d:25.4268;i:1600609001;d:26.064;i:1600608707;d:26.025700000000001;i:1600608405;d:25.778700000000001;i:1600608106;d:25.952200000000001;i:1600607806;d:25.693899999999999;i:1600607506;d:25.916899999999998;i:1600607211;d:25.400700000000001;i:1600606906;d:26.003;i:1600606610;d:25.7818;i:1600606307;d:25.289300000000001;i:1600606007;d:25.697199999999999;i:1600605705;d:25.718299999999999;i:1600605410;d:25.719899999999999;i:1600605107;d:25.397099999999998;i:1600604811;d:25.7209;i:1600604510;d:25.455400000000001;i:1600604206;d:25.485600000000002;i:1600603903;d:25.656400000000001;i:1600603606;d:25.767600000000002;i:1600603311;d:26.1998;i:1600603003;d:25.646000000000001;i:1600602712;d:26.403400000000001;i:1600602413;d:25.7224;i:1600602108;d:25.727;i:1600601808;d:25.998699999999999;i:1600601513;d:25.422499999999999;i:1600601213;d:25.6221;i:1600600905;d:25.508199999999999;i:1600600607;d:25.937000000000001;}s:17:\"discovery_history\";a:100:{i:1600686951;d:24.136199999999999;i:1600660646;d:24.472999999999999;i:1600573996;d:27.2515;i:1600487410;d:24.959599999999998;i:1600401044;d:24.527799999999999;i:1600314857;d:24.598500000000001;i:1600228693;d:25.225300000000001;i:1600141972;d:26.520099999999999;i:1600055218;d:25.139299999999999;i:1599969210;d:24.844799999999999;i:1599882407;d:25.0657;i:1599796853;d:24.6571;i:1599709483;d:28.338100000000001;i:1599623449;d:24.454699999999999;i:1599537241;d:24.7822;i:1599450746;d:25.1556;i:1599364836;d:24.966100000000001;i:1599277714;d:27.845099999999999;i:1599191555;d:24.5702;i:1599104888;d:25.022300000000001;i:1599019037;d:24.645600000000002;i:1598931882;d:25.8931;i:1598845927;d:24.769600000000001;i:1598760161;d:24.6464;i:1598672968;d:29.918500000000002;i:1598586451;d:24.6251;i:1598500189;d:24.8535;i:1598413692;d:25.033999999999999;i:1598327696;d:24.869599999999998;i:1598240885;d:24.401800000000001;i:1598154547;d:24.652000000000001;i:1598068147;d:24.925899999999999;i:1597982204;d:25.258099999999999;i:1597895719;d:26.281300000000002;i:1597808816;d:25.854099999999999;i:1597722701;d:24.770299999999999;i:1597636389;d:25.445499999999999;i:1597549534;d:25.739699999999999;i:1597463190;d:24.699000000000002;i:1597377449;d:24.635400000000001;i:1597290282;d:26.001200000000001;i:1597204236;d:24.3447;i:1597117728;d:24.980399999999999;i:1597032042;d:25.522300000000001;i:1596944311;d:26.455200000000001;i:1596858386;d:24.507899999999999;i:1596772267;d:24.5642;i:1596685403;d:25.946100000000001;i:1596599490;d:24.629799999999999;i:1596513290;d:27.129300000000001;i:1596426651;d:25.088899999999999;i:1596340165;d:25.0197;i:1596253774;d:24.832699999999999;i:1596167448;d:24.721499999999999;i:1596081035;d:24.725100000000001;i:1595994790;d:24.958500000000001;i:1595908257;d:24.529;i:1595821864;d:24.695399999999999;i:1595735470;d:24.849399999999999;i:1595648913;d:24.953600000000002;i:1595562560;d:24.750399999999999;i:1595476198;d:24.825500000000002;i:1595390014;d:24.916599999999999;i:1595303268;d:25.6065;i:1595217016;d:24.713899999999999;i:1595130409;d:24.722999999999999;i:1595044270;d:24.604600000000001;i:1594957770;d:24.7956;i:1594871285;d:24.803899999999999;i:1594784965;d:24.761600000000001;i:1594698503;d:24.767900000000001;i:1594612235;d:24.507200000000001;i:1594525747;d:24.753399999999999;i:1594439031;d:24.898;i:1594352414;d:25.188400000000001;i:1594266668;d:24.684999999999999;i:1594179827;d:25.705500000000001;i:1594093445;d:24.862200000000001;i:1594007461;d:24.318200000000001;i:1593921406;d:25.048999999999999;i:1593834345;d:27.6479;i:1593748338;d:25.305099999999999;i:1593661650;d:27.698499999999999;i:1593574845;d:25.219100000000001;i:1593489774;d:24.313300000000002;i:1593402284;d:30.803699999999999;i:1593316065;d:24.380099999999999;i:1593229663;d:25.1433;i:1593143927;d:25.618200000000002;i:1593056539;d:26.884899999999998;i:1592970569;d:25.198499999999999;i:1592883877;d:27.9695;i:1592797148;d:24.5518;i:1592711047;d:24.594100000000001;i:1592624857;d:25.7881;i:1592538455;d:26.4541;i:1592451841;d:26.505800000000001;i:1592365395;d:25.159199999999998;i:1592278983;d:26.078600000000002;i:1592192732;d:24.703399999999998;}s:18:\"discovery_mod_perf\";a:28:{s:2:\"os\";d:0.053600000000000002;s:4:\"mibs\";d:0.087999999999999995;s:5:\"ports\";d:1.2351000000000001;s:11:\"ports-stack\";d:0.73229999999999995;s:5:\"vlans\";d:0.1021;s:11:\"ports_vlans\";N;s:4:\"oids\";d:0.0012999999999999999;s:9:\"cisco-vrf\";d:0.00029999999999999997;s:12:\"ip-addresses\";d:0.67090000000000005;s:10:\"processors\";d:0.014500000000000001;s:8:\"mempools\";d:0.042700000000000002;s:9:\"inventory\";d:18.026399999999999;s:15:\"printersupplies\";d:0.0011000000000000001;s:7:\"sensors\";d:2.536;s:7:\"storage\";d:0.047699999999999999;s:10:\"neighbours\";d:0.035499999999999997;s:9:\"arp-table\";d:0.057000000000000002;s:13:\"junose-atm-vp\";d:0.00059999999999999995;s:9:\"bgp-peers\";d:0.0138;s:14:\"mac-accounting\";d:0.00040000000000000002;s:3:\"sla\";d:0.2016;s:11:\"pseudowires\";d:0.025600000000000001;s:16:\"virtual-machines\";d:0.00040000000000000002;s:11:\"cisco-cbqos\";d:0.1734;s:10:\"ucd-diskio\";d:0.046699999999999998;s:4:\"wifi\";d:0.0032000000000000002;s:10:\"p2p-radios\";d:0.00020000000000000001;s:6:\"graphs\";d:0.00050000000000000001;}}' WHERE `device_id` = '716']
SQL RUNTIME[0.00513291s]
#####  slx9140 [716] completed discovery modules at 2020-09-21 13:16:15  #####

 o Discovery time       24.1362 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '10362' AND `process_name` = 'discovery.php' AND `device_id` = '716']
SQL RUNTIME[0.00062990s]
#####  Finished discovery run at 2020-09-21 13:16:15  #####


SQL[SELECT * FROM `groups` ORDER BY `entity_type`]
SQL RUNTIME[0.00167298s]

SQL[SELECT * FROM `groups_assoc`]
SQL RUNTIME[0.00023794s]

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`os`, "") LIKE 'Microsens%')]
SQL RUNTIME[0.00062299s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '1']
SQL RUNTIME[0.00071502s]
Group                        'All Microsens': 130 existing, 130 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`hardware`, "") LIKE '9300%' AND IFNULL(`devices`.`hostname`, "") LIKE 'eswcs%')]
SQL RUNTIME[0.00130105s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '2']
SQL RUNTIME[0.00044179s]
Group                    'ACU Machine Group': 52 existing, 52 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`location`, "") LIKE 'CORE%' AND IFNULL(`devices`.`hostname`, "") REGEXP '[123]\\b')]
SQL RUNTIME[0.00135803s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '3']
SQL RUNTIME[0.00037503s]
Group                        'Network Cores': 16 existing, 16 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'eswobdc_a%')]
SQL RUNTIME[0.00065398s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '5']
SQL RUNTIME[0.00046515s]
Group                  'Network Aggregation': 18 existing, 18 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'eswobdc_e%')]
SQL RUNTIME[0.00071597s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '6']
SQL RUNTIME[0.00044894s]
Group                         'Network Edge': 42 existing, 42 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`location`, "") LIKE 'Beamline')]
SQL RUNTIME[0.00124478s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '7']
SQL RUNTIME[0.00057292s]
Group                            'Beamlines': 56 existing, 56 new entries (+0/-0).

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE 'wrs%')]
SQL RUNTIME[0.00048184s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '8']
SQL RUNTIME[0.00031018s]
Group                  'White Rabbit Switch': 2 existing, 2 new entries (+0/-0).

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00015497s]
Cached 16 alert rules.

SQL[SELECT * FROM `alert_assoc`]
SQL RUNTIME[0.00023103s]

SQL[SELECT `device_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `devices` WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`os`, "") LIKE 'microsens-g6') AND ( 1)))]
SQL RUNTIME[0.00221300s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '1']
SQL RUNTIME[0.00107408s]
Alert Checker               'Microsens Down': 126 existing, 126 new entries (+0/-0).

SQL[SELECT `port_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`hostname`, "") LIKE '%esw%') AND ( 1 AND IFNULL(`ifType`, "") NOT LIKE 'propVirtual' AND IFNULL(`ifType`, "") LIKE 'ethernetCsmacd' AND `ifSpeed` <= '1000000000' AND IFNULL(`ifAdminStatus`, "") NOT LIKE 'down'))) AND `deleted` != '1']
SQL RUNTIME[0.13888693s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '4']
SQL RUNTIME[0.11216712s]
Alert Checker                  'Port Errors': 24979 existing, 24981 new entries (+2/-0).

SQL[INSERT INTO `alert_table` (`device_id`,`entity_type`,`entity_id`,`alert_test_id`)  VALUES ('28','port','3436','4')]
SQL RUNTIME[0.00222611s]
SQL WARNINGS[
 1364: Field 'alert_assocs' doesn't have a default value
 1364: Field 'delay' doesn't have a default value
 1364: Field 'has_alerted' doesn't have a default value
 1364: Field 'last_message' doesn't have a default value
 1364: Field 'last_alerted' doesn't have a default value
 1364: Field 'state' doesn't have a default value
 1364: Field 'count' doesn't have a default value
]

SQL[SELECT last_insert_id();]
SQL RUNTIME[0.00073195s]

SQL[INSERT INTO `alert_table` (`device_id`,`entity_type`,`entity_id`,`alert_test_id`)  VALUES ('28','port','3574','4')]
SQL RUNTIME[0.00244904s]
SQL WARNINGS[
 1364: Field 'alert_assocs' doesn't have a default value
 1364: Field 'delay' doesn't have a default value
 1364: Field 'has_alerted' doesn't have a default value
 1364: Field 'last_message' doesn't have a default value
 1364: Field 'last_alerted' doesn't have a default value
 1364: Field 'state' doesn't have a default value
 1364: Field 'count' doesn't have a default value
]

SQL[SELECT last_insert_id();]
SQL RUNTIME[0.00014305s]

SQL[SELECT `status_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `status`  LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`hostname`, "") LIKE '%esw%') AND ( 1 AND `entPhysicalClass` = 'powersupply'))) AND `status_deleted` != '1']
SQL RUNTIME[0.02252197s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '11']
SQL RUNTIME[0.00430489s]
Alert Checker           'PowerSupply checks': 869 existing, 869 new entries (+0/-0).

SQL[SELECT `processor_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `processors`  LEFT JOIN `devices` ON (`processors`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`hostname`, "") LIKE '%esw%') AND ( 1)))]
SQL RUNTIME[0.00378990s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '12']
SQL RUNTIME[0.00628996s]
Alert Checker                     'High CPU': 815 existing, 815 new entries (+0/-0).

SQL[SELECT `mempool_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `mempools`  LEFT JOIN `devices` ON (`mempools`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`hostname`, "") LIKE '%esw%') AND ( 1))) AND `mempool_deleted` != '1']
SQL RUNTIME[0.00285697s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '13']
SQL RUNTIME[0.00509787s]
Alert Checker                  'High Memory': 581 existing, 581 new entries (+0/-0).

SQL[SELECT `bgpPeer_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `bgpPeers`  LEFT JOIN `devices` ON (`bgpPeers`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1)))]
SQL RUNTIME[0.00033498s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '14']
SQL RUNTIME[0.00030088s]
Alert Checker             'BGP Session down': 2 existing, 2 new entries (+0/-0).

SQL[SELECT `port_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`location`, "") LIKE 'CORE/MCS' AND `devices`.`hostname` IN ('eswobrmcs1','eswobrmcs2')) AND ( 1 AND IFNULL(`ifType`, "") NOT LIKE 'propVirtual'))) AND `deleted` != '1']
SQL RUNTIME[0.00175214s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '17']
SQL RUNTIME[0.00133896s]
Alert Checker              'Port down (MCS)': 202 existing, 202 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` IN ('5','3','6')]
SQL RUNTIME[0.00062084s]

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( `devices`.`device_id` IN ('2','3','4','7','10','167','168','248','251','270','474','475','642','643','729','730','11','78','104','105','106','107','109','110','111','113','146','147','249','250','407','408','616','617','12','13','14','15','16','17','18','19','20','21','115','116','117','118','119','120','121','122','123','124','125','126','128','129','130','131','132','133','134','136','137','138','139','140','141','142','143','165','173','578','579','590') AND `ports`.`ifType` != 'propVirtual' AND `ports`.`ifAdminStatus` != 'down' AND `ports`.`disabled` != '1') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.02313805s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '20']
SQL RUNTIME[0.01589298s]
Alert Checker             'Port Utilization': 3694 existing, 3694 new entries (+0/-0).

SQL[SELECT `storage_id`, `devices`.`device_id` as `device_id` FROM `storage`  LEFT JOIN `devices` ON (`storage`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`storage`.`storage_descr`, "") LIKE '/%' OR IFNULL(`storage`.`storage_descr`, "") REGEXP 'flash') AND `storage`.`storage_deleted` != '1']
SQL RUNTIME[0.00124502s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '21']
SQL RUNTIME[0.00104403s]
Alert Checker                   'Disk Usage': 167 existing, 167 new entries (+0/-0).

SQL[SELECT `status_id`, `devices`.`device_id` as `device_id` FROM `status`  LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%esw%' AND `status`.`entPhysicalClass` = 'fan') AND `status`.`status_deleted` != '1']
SQL RUNTIME[0.00677085s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '23']
SQL RUNTIME[0.01197314s]
Alert Checker                    'FAN speed': 2298 existing, 2298 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`devices`.`sysname`, "") REGEXP '\\beswr\\w+[12]' AND `devices`.`sysname` != 'eswrhsn3' AND IFNULL(`ports`.`ifType`, "") NOT LIKE 'propVirtual' AND `ports`.`ifName` != 'Management' AND IFNULL(`ports`.`ifName`, "") NOT LIKE 'mgmt%' AND IFNULL(`ports`.`port_label`, "") NOT REGEXP '^[1][(0-6)].*:*' AND IFNULL(`ports`.`port_label_base`, "") NOT LIKE 'Port-Channel') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.01620984s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '27']
SQL RUNTIME[0.01133299s]
Alert Checker             'Port down (CORE)': 1212 existing, 1212 new entries (+0/-0).
  String '1000000000' transformed by action [units] to: '1000000000'

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%esw%' AND IFNULL(`ports`.`ifType`, "") NOT LIKE 'propVirtual' AND IFNULL(`ports`.`ifType`, "") LIKE 'ethernetCsmacd' AND `ports`.`ifSpeed` > '1000000000' AND `ports`.`ifAdminStatus` != 'down') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.06454897s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '30']
SQL RUNTIME[0.01106000s]
Alert Checker            'Port Errors FIBER': 2765 existing, 2763 new entries (+0/-2).

SQL[DELETE FROM `alert_table` WHERE alert_test_id = '30' AND entity_id = '3589']
SQL RUNTIME[0.00954294s]

SQL[DELETE FROM `alert_table` WHERE alert_test_id = '30' AND entity_id = '45414']
SQL RUNTIME[0.00837016s]

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`sysname`, "") LIKE 'eswmwc%')]
SQL RUNTIME[0.00559616s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '31']
SQL RUNTIME[0.00044203s]
Alert Checker             'WC BlackBox down': 15 existing, 15 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( `devices`.`type` = 'firewall' AND IFNULL(`devices`.`location`, "") LIKE '%EPN%' AND IFNULL(`ports`.`ifName`, "") NOT REGEXP 'port(9|1[0-5])|mgmt2') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00136495s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '34']
SQL RUNTIME[0.00065207s]
Alert Checker         'Port down (Firewall)': 90 existing, 90 new entries (+0/-0).

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '2']
SQL RUNTIME[0.00022507s]

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( `devices`.`device_id` IN ('87','89','90','91','489','490','491','492','493','494','495','496','497','498','500','501','502','503','504','505','506','507','508','509','510','511','512','513','514','515','516','517','519','520','521','522','523','524','525','526','527','528','529','530','531','532','554','566','567','568','569','633') AND IFNULL(`ports`.`ifType`, "") NOT LIKE 'propVirtual' AND IFNULL(`ports`.`ifType`, "") LIKE 'ethernetCsmacd' AND `ports`.`ifAdminStatus` != 'down') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.01969004s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '35']
SQL RUNTIME[0.02231693s]
Alert Checker         'Port Erros (for ACU)': 5170 existing, 5170 new entries (+0/-0).

SQL[SELECT `status_id`, `devices`.`device_id` as `device_id` FROM `status`  LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%esw%' AND `status`.`entPhysicalClass` = 'stack') AND `status`.`status_deleted` != '1']
SQL RUNTIME[0.00455093s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '37']
SQL RUNTIME[0.00107884s]
Alert Checker                  'STACK check': 221 existing, 221 new entries (+0/-0).
./discovery.php: slx9140 - 1 devices discovered in 24.34 secs

SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1600672551']
SQL RUNTIME[0.00026679s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       24.34 secs
 o Memory usage         110MB (peak: 117.6MB)
 o MySQL Usage          Cell[154/0.134s] Row[282/0.214s] Rows[126/0.705s] Column[10/0.006s] Update[6/0.012s] Insert[3/0.007s] 
                        Delete[4/0.019s]
 o RRDTool Usage