DEBUG! CMD[[0;33m/usr/bin/svn info /opt/observium[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0168s[0m][0m STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/branches/stable Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 10586 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 10549 Last Changed Date: 2020-07-03 05:29:01 +0100 (Fri, 03 Jul 2020) ] SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';[0m][0m SQL RUNTIME[[0;32m0.00022101s[0m][0m SQL[[0;33mSELECT @@SESSION.sql_mode;[0m][0m SQL RUNTIME[[0;32m0.00007701s[0m][0m SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';[0m][0m SQL RUNTIME[[0;32m0.00014114s[0m][0m SQL[[0;33mSELECT * FROM `config`[0m][0m SQL RUNTIME[[0;32m0.00011516s[0m][0m CMD[[0;33m/bin/hostname -f[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0023s[0m][0m STDOUT[ vms016.plants.internal ] [1;37m ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_|[0;36m Observium Professional 20.7.10549 http://www.observium.org[0m [0m CMD[[0;33m/opt/observium/scripts/distro[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0182s[0m][0m STDOUT[ Linux|3.10.0-1127.13.1.el7.x86_64|amd64|CentOS|7|vmware| ] CMD[[0;33m/usr/bin/env python --version 2>&1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0029s[0m][0m STDOUT[ Python 2.7.5 ] SQL[[0;33mSELECT version();[0m][0m SQL RUNTIME[[0;32m0.00010800s[0m][0m CMD[[0;33m/usr/bin/snmpget --version 2>&1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0053s[0m][0m STDOUT[ NET-SNMP version: 5.7.2 ] CMD[[0;33m/usr/bin/rrdtool --version | head -n1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0064s[0m][0m STDOUT[ RRDtool 1.7.1 Copyright by Tobias Oetiker <tobi@oetiker.ch> ] CMD[[0;33m/usr/bin/rrdcached -h | head -n1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0059s[0m][0m STDOUT[ RRDCacheD 1.7.1 ] CMD[[0;33m/sbin/fping -v 2>&1[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0025s[0m][0m STDOUT[ /sbin/fping: Version 3.10 /sbin/fping: comments to david@schweikert.ch ] CMD[[0;33m/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}'[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0025s[0m][0m STDOUT[ ] CMD[[0;33m/usr/sbin/httpd -v | awk '/Server version:/ {print $3}'[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0294s[0m][0m STDOUT[ Apache/2.4.6 ] CMD[[0;33mdate "+%:z"[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0018s[0m][0m STDOUT[ +01:00 ] SQL[[0;33mSELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);[0m][0m SQL RUNTIME[[0;32m0.00018406s[0m][0m SQL[[0;33mSELECT @@SESSION.sql_mode;[0m][0m SQL RUNTIME[[0;32m0.00009799s[0m][0m SQL[[0;33mSHOW VARIABLES LIKE 'character_set_connection'[0m][0m SQL RUNTIME[[0;32m0.00039291s[0m][0m [0;36m##### [1;37mSoftware versions[0;36m #####[0m [0m [0;36m o [1;37mOS [0m Linux 3.10.0-1127.13.1.el7.x86_64 [amd64] (CentOS 7) [0;36m o [1;37mApache [0m 2.4.6 [0;36m o [1;37mPHP [0m 7.0.33 (OPcache: DISABLED) [0;36m o [1;37mPython [0m 2.7.5 [0;36m o [1;37mMariaDB [0m 5.5.65-MariaDB (extension: mysqli 5.5.65-MariaDB) [0;36m o [1;37mSNMP [0m NET-SNMP 5.7.2 [0;36m o [1;37mRRDtool [0m 1.7.1 (rrdcached 1.7.1: unix:/run/rrdcached.sock) [0;36m o [1;37mFping [0m 3.10 (IPv4 only) [0;35m##### [1;37mMemory Limit[0;35m #####[0m [0m [0;35m o [1;37mPHP [0m [0;31m128MB [0;35m##### [1;37mMariaDB mode[0;35m #####[0m [0m [0;35m o [1;37mMariaDB [0m [0;35m##### [1;37mCharset info[0;35m #####[0m [0m [0;35m o [1;37mPHP [0m UTF-8 [0;35m o [1;37mMariaDB [0m utf8 [0;35m##### [1;37mTimezones info[0;35m #####[0m [0m [0;35m o [1;37mDate [0m Monday, 13-Jul-20 12:26:57 BST [0;35m o [1;37mPHP [0m +01:00 [0;35m o [1;37mMariaDB [0m +01:00 SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';[0m][0m SQL RUNTIME[[0;32m0.00018001s[0m][0m SQL[[0;33mSELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';[0m][0m SQL RUNTIME[[0;32m0.00011683s[0m][0m [1;37m##### [1;37m[1;37mStarting discovery run at 2020-07-13 12:26:57[1;37m #####[0m [0m SQL[[0;33mSELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'ssw006' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC[0m][0m SQL RUNTIME[[0;32m0.00046706s[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' sysObjectID.0 sysUpTime.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0107s[0m][0m STDOUT[ sysObjectID.0 = enterprises.674.11000.5000.100.2.1.20 sysUpTime.0 = 0:0:31:34.53 ] SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00019407s[0m][0m SQL[[0;33mSELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014997s[0m][0m SQL[[0;33mINSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('655','discovery.php','9953','0','php ./discovery.php -d -h ssw006','1594639617','84')[0m][0m SQL RUNTIME[[0;32m0.00055814s[0m][0m [0;32m##### [1;37mssw006 [84][0;32m #####[0m [0m [0;32m o [1;37mOS Type [0m dell-os10 [0;32m o [1;37mSNMP Version [0m v2c [0;32m o [1;37mLast discovery [0m 2020-07-13 12:20:35 [0;32m o [1;37mLast duration [0m 5.24 seconds [0;36m##### [1;37mModule Start: [1;31mos[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' sysDescr.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0096s[0m][0m STDOUT[ Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' sysObjectID.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0094s[0m][0m STDOUT[ .1.3.6.1.4.1.674.11000.5000.100.2.1.20 ] SNMP STATUS[[0;32mTRUE[0m][0m +-------------+----------------------------------------------------------------------------------------------------------------------------------+ | [37;1mOID[0m | | +-------------+----------------------------------------------------------------------------------------------------------------------------------+ | sysDescr | Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterpri | | | se. OS Version: 10.5.0.4. System Type: S5232F-ON | | sysObjectID | .1.3.6.1.4.1.674.11000.5000.100.2.1.20 | +-------------+----------------------------------------------------------------------------------------------------------------------------------+ [0;35m o [1;37mDetect OS matched (dell-os10: Dell OS10):[0m +----------+-----------------------------+-------------------------------------------------------------------------------------------------------+ | [37;1mOID[0m | [37;1mMatched definition[0m | | +----------+-----------------------------+-------------------------------------------------------------------------------------------------------+ | sysDescr | /^Dell EMC Networking OS10/ | Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System | | | | Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON | +----------+-----------------------------+-------------------------------------------------------------------------------------------------------+ [0;36m o [1;37mDuration [0m 0.0534s [0;36m##### [1;37mModule Start: [1;31mmibs[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID'[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0085s[0m][0m STDOUT[ .1.3.6.1.2.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2' CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' .1.3.6.1.2.1.1.9.1.2[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0094s[0m][0m STDOUT[ .1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1 .1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.16.2.2.1 .1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.2.1.49 .1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.2.1.4 .1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.2.1.50 .1.3.6.1.2.1.1.9.1.2.6 = .1.3.6.1.6.3.11.3.1.1 .1.3.6.1.2.1.1.9.1.2.7 = .1.3.6.1.6.3.15.2.1.1 .1.3.6.1.2.1.1.9.1.2.8 = .1.3.6.1.6.3.10.3.1.1 .1.3.6.1.2.1.1.9.1.2.9 = .1.3.6.1.6.3.13.3.1.3 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' sysORDescr[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0094s[0m][0m STDOUT[ sysORDescr.1 = The MIB module for SNMPv2 entities sysORDescr.2 = View-based Access Control Model for SNMP. sysORDescr.3 = The MIB module for managing TCP implementations sysORDescr.4 = The MIB module for managing IP and ICMP implementations sysORDescr.5 = The MIB module for managing UDP implementations sysORDescr.6 = The MIB for Message Processing and Dispatching. sysORDescr.7 = The management information definitions for the SNMP User-based Security Model. sysORDescr.8 = The SNMP Management Architecture MIB. sysORDescr.9 = The MIB modules for managing SNMP Notification, plus filtering. ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ospfAdminStat.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0133s[0m][0m STDOUT[ No Such Instance currently exists at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m Store in cache OID: OSPF-MIB::ospfAdminStat.0 CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m MPLS-L3VPN-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' mplsL3VpnConfiguredVrfs.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0137s[0m][0m STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m Store in cache OID: MPLS-L3VPN-STD-MIB::mplsL3VpnConfiguredVrfs.0 [0;36m o [1;37mMIBs discovered [0m TCP-MIB UDP-MIB +-----------------------+--------------------+---------+---------------------+ | [37;1mIdentity[0m | [37;1mMIB[0m | [37;1mSource[0m | [37;1mStatus[0m | +-----------------------+--------------------+---------+---------------------+ | .1.3.6.1.6.3.1 | SNMPv2-MIB | sysORID | [33mMIB already defined[0m | | .1.3.6.1.2.1.4 | IP-MIB | sysORID | [33mMIB already defined[0m | | .1.3.6.1.2.1.49 | [32mTCP-MIB[0m | sysORID | [32mMIB added[0m | | .1.3.6.1.2.1.50 | [32mUDP-MIB[0m | sysORID | [32mMIB added[0m | | .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | [33mMIB already defined[0m | | .1.3.6.1.6.3.16.2.2.1 | - | sysORID | [36mUnknown Identity[0m | | .1.3.6.1.6.3.11.3.1.1 | - | sysORID | [36mUnknown Identity[0m | | .1.3.6.1.6.3.15.2.1.1 | - | sysORID | [36mUnknown Identity[0m | | .1.3.6.1.6.3.13.3.1.3 | - | sysORID | [36mUnknown Identity[0m | +-----------------------+--------------------+---------+---------------------+ [0;36m o [1;37mDuration [0m 0.0674s [0;36m##### [1;37mModule Start: [1;31mports[0;36m #####[0m [0m [0;35m o [1;37mCaching OIDs [0m SQL[[0;33mSELECT `mib` FROM `devices_mibs` WHERE `device_id` = '84' AND `use` = 'mib' AND `disabled` = '1'[0m][0m SQL RUNTIME[[0;32m0.00029993s[0m][0m ifDescr CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifDescr[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0338s[0m][0m STDOUT[ ifDescr.9 = mgmt1/1/1 ifDescr.11 = ethernet1/1/1 ifDescr.12 = ethernet1/1/2 ifDescr.13 = ethernet1/1/3 ifDescr.14 = ethernet1/1/4 ifDescr.15 = ethernet1/1/5 ifDescr.16 = ethernet1/1/6 ifDescr.17 = ethernet1/1/7 ifDescr.18 = ethernet1/1/8 ifDescr.19 = ethernet1/1/9 ifDescr.20 = ethernet1/1/10 ifDescr.21 = ethernet1/1/11 ifDescr.22 = ethernet1/1/12 ifDescr.23 = ethernet1/1/13 ifDescr.24 = ethernet1/1/14 ifDescr.25 = ethernet1/1/15 ifDescr.26 = ethernet1/1/16 ifDescr.27 = ethernet1/1/17 ifDescr.28 = ethernet1/1/18 ifDescr.29 = ethernet1/1/19 ifDescr.30 = ethernet1/1/20 ifDescr.31 = ethernet1/1/21 ifDescr.32 = ethernet1/1/22 ifDescr.33 = ethernet1/1/23 ifDescr.34 = ethernet1/1/24 ifDescr.35 = ethernet1/1/25 ifDescr.36 = ethernet1/1/26 ifDescr.37 = ethernet1/1/27 ifDescr.38 = ethernet1/1/28 ifDescr.39 = ethernet1/1/29 ifDescr.40 = ethernet1/1/30 ifDescr.41 = ethernet1/1/31 ifDescr.42 = ethernet1/1/32 ifDescr.43 = ethernet1/1/33 ifDescr.44 = ethernet1/1/34 ifDescr.45 = vlan1 ] SNMP STATUS[[0;32mTRUE[0m][0m ifAlias CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifAlias[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0311s[0m][0m STDOUT[ ifAlias.9 = ifAlias.11 = ifAlias.12 = ifAlias.13 = ifAlias.14 = ifAlias.15 = ifAlias.16 = ifAlias.17 = ifAlias.18 = ifAlias.19 = ifAlias.20 = ifAlias.21 = ifAlias.22 = ifAlias.23 = ifAlias.24 = ifAlias.25 = ifAlias.26 = ifAlias.27 = ifAlias.28 = ifAlias.29 = ifAlias.30 = ifAlias.31 = ifAlias.32 = ifAlias.33 = ifAlias.34 = ifAlias.35 = ifAlias.36 = ifAlias.37 = ifAlias.38 = ifAlias.39 = ifAlias.40 = ifAlias.41 = ifAlias.42 = ifAlias.43 = ifAlias.44 = ifAlias.45 = ] SNMP STATUS[[0;32mTRUE[0m][0m ifName CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifName[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.039s[0m][0m STDOUT[ ifName.9 = mgmt1/1/1 ifName.11 = ethernet1/1/1 ifName.12 = ethernet1/1/2 ifName.13 = ethernet1/1/3 ifName.14 = ethernet1/1/4 ifName.15 = ethernet1/1/5 ifName.16 = ethernet1/1/6 ifName.17 = ethernet1/1/7 ifName.18 = ethernet1/1/8 ifName.19 = ethernet1/1/9 ifName.20 = ethernet1/1/10 ifName.21 = ethernet1/1/11 ifName.22 = ethernet1/1/12 ifName.23 = ethernet1/1/13 ifName.24 = ethernet1/1/14 ifName.25 = ethernet1/1/15 ifName.26 = ethernet1/1/16 ifName.27 = ethernet1/1/17 ifName.28 = ethernet1/1/18 ifName.29 = ethernet1/1/19 ifName.30 = ethernet1/1/20 ifName.31 = ethernet1/1/21 ifName.32 = ethernet1/1/22 ifName.33 = ethernet1/1/23 ifName.34 = ethernet1/1/24 ifName.35 = ethernet1/1/25 ifName.36 = ethernet1/1/26 ifName.37 = ethernet1/1/27 ifName.38 = ethernet1/1/28 ifName.39 = ethernet1/1/29 ifName.40 = ethernet1/1/30 ifName.41 = ethernet1/1/31 ifName.42 = ethernet1/1/32 ifName.43 = ethernet1/1/33 ifName.44 = ethernet1/1/34 ifName.45 = vlan1 ] SNMP STATUS[[0;32mTRUE[0m][0m ifType CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifType[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0296s[0m][0m STDOUT[ ifType.9 = ethernetCsmacd ifType.11 = ethernetCsmacd ifType.12 = ethernetCsmacd ifType.13 = ethernetCsmacd ifType.14 = ethernetCsmacd ifType.15 = ethernetCsmacd ifType.16 = ethernetCsmacd ifType.17 = ethernetCsmacd ifType.18 = ethernetCsmacd ifType.19 = ethernetCsmacd ifType.20 = ethernetCsmacd ifType.21 = ethernetCsmacd ifType.22 = ethernetCsmacd ifType.23 = ethernetCsmacd ifType.24 = ethernetCsmacd ifType.25 = ethernetCsmacd ifType.26 = ethernetCsmacd ifType.27 = ethernetCsmacd ifType.28 = ethernetCsmacd ifType.29 = ethernetCsmacd ifType.30 = ethernetCsmacd ifType.31 = ethernetCsmacd ifType.32 = ethernetCsmacd ifType.33 = ethernetCsmacd ifType.34 = ethernetCsmacd ifType.35 = ethernetCsmacd ifType.36 = ethernetCsmacd ifType.37 = ethernetCsmacd ifType.38 = ethernetCsmacd ifType.39 = ethernetCsmacd ifType.40 = ethernetCsmacd ifType.41 = ethernetCsmacd ifType.42 = ethernetCsmacd ifType.43 = ethernetCsmacd ifType.44 = ethernetCsmacd ifType.45 = l2vlan ] SNMP STATUS[[0;32mTRUE[0m][0m ifOperStatus CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifOperStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0319s[0m][0m STDOUT[ ifOperStatus.9 = up ifOperStatus.11 = up ifOperStatus.12 = down ifOperStatus.13 = down ifOperStatus.14 = down ifOperStatus.15 = down ifOperStatus.16 = down ifOperStatus.17 = down ifOperStatus.18 = down ifOperStatus.19 = down ifOperStatus.20 = down ifOperStatus.21 = down ifOperStatus.22 = down ifOperStatus.23 = down ifOperStatus.24 = up ifOperStatus.25 = down ifOperStatus.26 = up ifOperStatus.27 = down ifOperStatus.28 = down ifOperStatus.29 = down ifOperStatus.30 = down ifOperStatus.31 = down ifOperStatus.32 = down ifOperStatus.33 = down ifOperStatus.34 = down ifOperStatus.35 = down ifOperStatus.36 = down ifOperStatus.37 = down ifOperStatus.38 = down ifOperStatus.39 = up ifOperStatus.40 = up ifOperStatus.41 = up ifOperStatus.42 = up ifOperStatus.43 = down ifOperStatus.44 = down ifOperStatus.45 = up ] SNMP STATUS[[0;32mTRUE[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/ports.inc.php:45 [0m array( [9] => array( [ifDescr] => string(9) "mgmt1/1/1" [ifAlias] => string(0) "" [ifName] => string(9) "mgmt1/1/1" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [11] => array( [ifDescr] => string(13) "ethernet1/1/1" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/1" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [12] => array( [ifDescr] => string(13) "ethernet1/1/2" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/2" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [13] => array( [ifDescr] => string(13) "ethernet1/1/3" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/3" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [14] => array( [ifDescr] => string(13) "ethernet1/1/4" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/4" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [15] => array( [ifDescr] => string(13) "ethernet1/1/5" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/5" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [16] => array( [ifDescr] => string(13) "ethernet1/1/6" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/6" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [17] => array( [ifDescr] => string(13) "ethernet1/1/7" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/7" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [18] => array( [ifDescr] => string(13) "ethernet1/1/8" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/8" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [19] => array( [ifDescr] => string(13) "ethernet1/1/9" [ifAlias] => string(0) "" [ifName] => string(13) "ethernet1/1/9" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [20] => array( [ifDescr] => string(14) "ethernet1/1/10" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/10" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [21] => array( [ifDescr] => string(14) "ethernet1/1/11" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/11" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [22] => array( [ifDescr] => string(14) "ethernet1/1/12" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/12" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [23] => array( [ifDescr] => string(14) "ethernet1/1/13" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/13" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [24] => array( [ifDescr] => string(14) "ethernet1/1/14" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/14" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [25] => array( [ifDescr] => string(14) "ethernet1/1/15" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/15" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [26] => array( [ifDescr] => string(14) "ethernet1/1/16" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/16" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [27] => array( [ifDescr] => string(14) "ethernet1/1/17" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/17" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [28] => array( [ifDescr] => string(14) "ethernet1/1/18" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/18" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [29] => array( [ifDescr] => string(14) "ethernet1/1/19" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/19" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [30] => array( [ifDescr] => string(14) "ethernet1/1/20" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/20" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [31] => array( [ifDescr] => string(14) "ethernet1/1/21" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/21" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [32] => array( [ifDescr] => string(14) "ethernet1/1/22" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/22" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [33] => array( [ifDescr] => string(14) "ethernet1/1/23" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/23" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [34] => array( [ifDescr] => string(14) "ethernet1/1/24" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/24" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [35] => array( [ifDescr] => string(14) "ethernet1/1/25" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/25" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [36] => array( [ifDescr] => string(14) "ethernet1/1/26" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/26" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [37] => array( [ifDescr] => string(14) "ethernet1/1/27" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/27" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [38] => array( [ifDescr] => string(14) "ethernet1/1/28" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/28" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [39] => array( [ifDescr] => string(14) "ethernet1/1/29" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/29" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [40] => array( [ifDescr] => string(14) "ethernet1/1/30" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/30" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [41] => array( [ifDescr] => string(14) "ethernet1/1/31" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/31" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [42] => array( [ifDescr] => string(14) "ethernet1/1/32" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/32" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(2) "up" ) [43] => array( [ifDescr] => string(14) "ethernet1/1/33" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/33" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [44] => array( [ifDescr] => string(14) "ethernet1/1/34" [ifAlias] => string(0) "" [ifName] => string(14) "ethernet1/1/34" [ifType] => string(14) "ethernetCsmacd" [ifOperStatus] => string(4) "down" ) [45] => array( [ifDescr] => string(5) "vlan1" [ifAlias] => string(0) "" [ifName] => string(5) "vlan1" [ifType] => string(6) "l2vlan" [ifOperStatus] => string(2) "up" ) ) [0;35m o [1;37mCaching DB [0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00080585s[0m][0m 36 ports [0;35m o [1;37mDiscovering ports [0m .................................... +---------+----------------+----------------+---------+----------------+-------------+---------+ | [37;1mifIndex[0m | [37;1mifDescr[0m | [37;1mifName[0m | [37;1mifAlias[0m | [37;1mifType[0m | [37;1mOper Status[0m | [37;1mIgnored[0m | +---------+----------------+----------------+---------+----------------+-------------+---------+ | 9 | mgmt1/1/1 | mgmt1/1/1 | ... | ethernetCsmacd | up | [32mno[0m | | 11 | ethernet1/1/1 | ethernet1/1/1 | ... | ethernetCsmacd | up | [32mno[0m | | 12 | ethernet1/1/2 | ethernet1/1/2 | ... | ethernetCsmacd | down | [32mno[0m | | 13 | ethernet1/1/3 | ethernet1/1/3 | ... | ethernetCsmacd | down | [32mno[0m | | 14 | ethernet1/1/4 | ethernet1/1/4 | ... | ethernetCsmacd | down | [32mno[0m | | 15 | ethernet1/1/5 | ethernet1/1/5 | ... | ethernetCsmacd | down | [32mno[0m | | 16 | ethernet1/1/6 | ethernet1/1/6 | ... | ethernetCsmacd | down | [32mno[0m | | 17 | ethernet1/1/7 | ethernet1/1/7 | ... | ethernetCsmacd | down | [32mno[0m | | 18 | ethernet1/1/8 | ethernet1/1/8 | ... | ethernetCsmacd | down | [32mno[0m | | 19 | ethernet1/1/9 | ethernet1/1/9 | ... | ethernetCsmacd | down | [32mno[0m | | 20 | ethernet1/1/10 | ethernet1/1/10 | ... | ethernetCsmacd | down | [32mno[0m | | 21 | ethernet1/1/11 | ethernet1/1/11 | ... | ethernetCsmacd | down | [32mno[0m | | 22 | ethernet1/1/12 | ethernet1/1/12 | ... | ethernetCsmacd | down | [32mno[0m | | 23 | ethernet1/1/13 | ethernet1/1/13 | ... | ethernetCsmacd | down | [32mno[0m | | 24 | ethernet1/1/14 | ethernet1/1/14 | ... | ethernetCsmacd | up | [32mno[0m | | 25 | ethernet1/1/15 | ethernet1/1/15 | ... | ethernetCsmacd | down | [32mno[0m | | 26 | ethernet1/1/16 | ethernet1/1/16 | ... | ethernetCsmacd | up | [32mno[0m | | 27 | ethernet1/1/17 | ethernet1/1/17 | ... | ethernetCsmacd | down | [32mno[0m | | 28 | ethernet1/1/18 | ethernet1/1/18 | ... | ethernetCsmacd | down | [32mno[0m | | 29 | ethernet1/1/19 | ethernet1/1/19 | ... | ethernetCsmacd | down | [32mno[0m | | 30 | ethernet1/1/20 | ethernet1/1/20 | ... | ethernetCsmacd | down | [32mno[0m | | 31 | ethernet1/1/21 | ethernet1/1/21 | ... | ethernetCsmacd | down | [32mno[0m | | 32 | ethernet1/1/22 | ethernet1/1/22 | ... | ethernetCsmacd | down | [32mno[0m | | 33 | ethernet1/1/23 | ethernet1/1/23 | ... | ethernetCsmacd | down | [32mno[0m | | 34 | ethernet1/1/24 | ethernet1/1/24 | ... | ethernetCsmacd | down | [32mno[0m | | 35 | ethernet1/1/25 | ethernet1/1/25 | ... | ethernetCsmacd | down | [32mno[0m | | 36 | ethernet1/1/26 | ethernet1/1/26 | ... | ethernetCsmacd | down | [32mno[0m | | 37 | ethernet1/1/27 | ethernet1/1/27 | ... | ethernetCsmacd | down | [32mno[0m | | 38 | ethernet1/1/28 | ethernet1/1/28 | ... | ethernetCsmacd | down | [32mno[0m | | 39 | ethernet1/1/29 | ethernet1/1/29 | ... | ethernetCsmacd | up | [32mno[0m | | 40 | ethernet1/1/30 | ethernet1/1/30 | ... | ethernetCsmacd | up | [32mno[0m | | 41 | ethernet1/1/31 | ethernet1/1/31 | ... | ethernetCsmacd | up | [32mno[0m | | 42 | ethernet1/1/32 | ethernet1/1/32 | ... | ethernetCsmacd | up | [32mno[0m | | 43 | ethernet1/1/33 | ethernet1/1/33 | ... | ethernetCsmacd | down | [32mno[0m | | 44 | ethernet1/1/34 | ethernet1/1/34 | ... | ethernetCsmacd | down | [32mno[0m | | 45 | vlan1 | vlan1 | ... | l2vlan | up | [32mno[0m | +---------+----------------+----------------+---------+----------------+-------------+---------+ [0;36m o [1;37mDuration [0m 0.2087s [0;36m##### [1;37mModule Start: [1;31mports-stack[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00018311s[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ifStackStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.1002s[0m][0m STDOUT[ ifStackStatus = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m [0;36m o [1;37mDuration [0m 0.1021s [0;36m##### [1;37mModule Start: [1;31mvlans[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '84';[0m][0m SQL RUNTIME[[0;32m0.00028992s[0m][0m SQL[[0;33mSELECT * FROM `ports_vlans` WHERE `device_id` = '84';[0m][0m SQL RUNTIME[[0;32m0.00023794s[0m][0m [0;36m o [1;37mQ-BRIDGE-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dot1qVlanStaticName[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0247s[0m][0m STDOUT[ dot1qVlanStaticName.1 = vlan1 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dot1qVlanStaticRowStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0472s[0m][0m STDOUT[ dot1qVlanStaticRowStatus.1 = active ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsx --hexOutputLength=0 -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dot1qVlanStaticEgressPorts[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0239s[0m][0m STDOUT[ dot1qVlanStaticEgressPorts.1 = "7F FF FF FF E0 " ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dot1dBasePortIfIndex[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0321s[0m][0m STDOUT[ dot1dBasePortIfIndex.2 = 11 dot1dBasePortIfIndex.3 = 12 dot1dBasePortIfIndex.4 = 13 dot1dBasePortIfIndex.5 = 14 dot1dBasePortIfIndex.6 = 15 dot1dBasePortIfIndex.7 = 16 dot1dBasePortIfIndex.8 = 17 dot1dBasePortIfIndex.9 = 18 dot1dBasePortIfIndex.10 = 19 dot1dBasePortIfIndex.11 = 20 dot1dBasePortIfIndex.12 = 21 dot1dBasePortIfIndex.13 = 22 dot1dBasePortIfIndex.14 = 23 dot1dBasePortIfIndex.15 = 24 dot1dBasePortIfIndex.16 = 25 dot1dBasePortIfIndex.17 = 26 dot1dBasePortIfIndex.18 = 27 dot1dBasePortIfIndex.19 = 28 dot1dBasePortIfIndex.20 = 29 dot1dBasePortIfIndex.21 = 30 dot1dBasePortIfIndex.22 = 31 dot1dBasePortIfIndex.23 = 32 dot1dBasePortIfIndex.24 = 33 dot1dBasePortIfIndex.25 = 34 dot1dBasePortIfIndex.26 = 35 dot1dBasePortIfIndex.27 = 36 dot1dBasePortIfIndex.28 = 37 dot1dBasePortIfIndex.29 = 38 dot1dBasePortIfIndex.30 = 39 dot1dBasePortIfIndex.31 = 40 dot1dBasePortIfIndex.32 = 41 dot1dBasePortIfIndex.33 = 42 dot1dBasePortIfIndex.34 = 43 dot1dBasePortIfIndex.35 = 44 dot1dBasePortIfIndex.36 = 9 ] SNMP STATUS[[0;32mTRUE[0m][0m Store in cache Table OID: BRIDGE-MIB::dot1dBasePortIfIndex CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m Q-BRIDGE-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dot1qPvid[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0199s[0m][0m STDOUT[ dot1qPvid = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m 1+--------+----------+-------+----------+-------------+ | [37;1mDomain[0m | [37;1mVlan: ID[0m | [37;1mName[0m | [37;1mType[0m | [37;1mStatus[0m | +--------+----------+-------+----------+-------------+ | 1 | 1 | vlan1 | ethernet | operational | +--------+----------+-------+----------+-------------+ SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '11' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00034499s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2072'[0m][0m SQL RUNTIME[[0;32m0.00031781s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2072'[0m][0m SQL RUNTIME[[0;32m0.00019097s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00022602s[0m][0m SQL[[0;33mSELECT * FROM `device_graphs` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00022411s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2532'[0m][0m SQL RUNTIME[[0;32m0.00052595s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '12' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013304s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2073'[0m][0m SQL RUNTIME[[0;32m0.00020695s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2073'[0m][0m SQL RUNTIME[[0;32m0.00015998s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2533'[0m][0m SQL RUNTIME[[0;32m0.00041604s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '13' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013018s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2074'[0m][0m SQL RUNTIME[[0;32m0.00021696s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2074'[0m][0m SQL RUNTIME[[0;32m0.00015903s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2534'[0m][0m SQL RUNTIME[[0;32m0.00054812s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '14' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012994s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2075'[0m][0m SQL RUNTIME[[0;32m0.00020194s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2075'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2535'[0m][0m SQL RUNTIME[[0;32m0.00043201s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '15' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012994s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2076'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2076'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2536'[0m][0m SQL RUNTIME[[0;32m0.00041699s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '16' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012779s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2077'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2077'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2537'[0m][0m SQL RUNTIME[[0;32m0.00047302s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '17' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00017309s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2078'[0m][0m SQL RUNTIME[[0;32m0.00020385s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2078'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2538'[0m][0m SQL RUNTIME[[0;32m0.00041318s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '18' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012779s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2079'[0m][0m SQL RUNTIME[[0;32m0.00020123s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2079'[0m][0m SQL RUNTIME[[0;32m0.00015593s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2539'[0m][0m SQL RUNTIME[[0;32m0.00045896s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '19' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013614s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2080'[0m][0m SQL RUNTIME[[0;32m0.00021100s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2080'[0m][0m SQL RUNTIME[[0;32m0.00016189s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2540'[0m][0m SQL RUNTIME[[0;32m0.00041914s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '20' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012994s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2081'[0m][0m SQL RUNTIME[[0;32m0.00020385s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2081'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2541'[0m][0m SQL RUNTIME[[0;32m0.00042105s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '21' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012803s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2082'[0m][0m SQL RUNTIME[[0;32m0.00022602s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2082'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2542'[0m][0m SQL RUNTIME[[0;32m0.00043678s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '22' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013018s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2083'[0m][0m SQL RUNTIME[[0;32m0.00020385s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2083'[0m][0m SQL RUNTIME[[0;32m0.00015807s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2543'[0m][0m SQL RUNTIME[[0;32m0.00040603s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '23' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012803s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2084'[0m][0m SQL RUNTIME[[0;32m0.00022292s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2084'[0m][0m SQL RUNTIME[[0;32m0.00015593s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2544'[0m][0m SQL RUNTIME[[0;32m0.00040412s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '24' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012708s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2085'[0m][0m SQL RUNTIME[[0;32m0.00020194s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2085'[0m][0m SQL RUNTIME[[0;32m0.00015593s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2545'[0m][0m SQL RUNTIME[[0;32m0.00098419s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '25' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012779s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2086'[0m][0m SQL RUNTIME[[0;32m0.00020003s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2086'[0m][0m SQL RUNTIME[[0;32m0.00015497s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2546'[0m][0m SQL RUNTIME[[0;32m0.00042486s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '26' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012708s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2087'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2087'[0m][0m SQL RUNTIME[[0;32m0.00015616s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2547'[0m][0m SQL RUNTIME[[0;32m0.00042295s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '27' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013208s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2088'[0m][0m SQL RUNTIME[[0;32m0.00019908s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2088'[0m][0m SQL RUNTIME[[0;32m0.00015593s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2548'[0m][0m SQL RUNTIME[[0;32m0.00043988s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '28' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012803s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2089'[0m][0m SQL RUNTIME[[0;32m0.00020003s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2089'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2549'[0m][0m SQL RUNTIME[[0;32m0.00043011s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '29' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00014901s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2090'[0m][0m SQL RUNTIME[[0;32m0.00027108s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2090'[0m][0m SQL RUNTIME[[0;32m0.00018811s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2550'[0m][0m SQL RUNTIME[[0;32m0.00040603s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '30' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012898s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2091'[0m][0m SQL RUNTIME[[0;32m0.00022602s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2091'[0m][0m SQL RUNTIME[[0;32m0.00015688s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2551'[0m][0m SQL RUNTIME[[0;32m0.00041103s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '31' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012708s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2092'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2092'[0m][0m SQL RUNTIME[[0;32m0.00015616s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2552'[0m][0m SQL RUNTIME[[0;32m0.00044703s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '32' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012589s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2093'[0m][0m SQL RUNTIME[[0;32m0.00021601s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2093'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2553'[0m][0m SQL RUNTIME[[0;32m0.00040388s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '33' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00014210s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2094'[0m][0m SQL RUNTIME[[0;32m0.00020409s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2094'[0m][0m SQL RUNTIME[[0;32m0.00015783s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2554'[0m][0m SQL RUNTIME[[0;32m0.00043106s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '34' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012803s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2095'[0m][0m SQL RUNTIME[[0;32m0.00020003s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2095'[0m][0m SQL RUNTIME[[0;32m0.00016999s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2555'[0m][0m SQL RUNTIME[[0;32m0.00040984s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '35' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2096'[0m][0m SQL RUNTIME[[0;32m0.00029993s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2096'[0m][0m SQL RUNTIME[[0;32m0.00017500s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2556'[0m][0m SQL RUNTIME[[0;32m0.00043201s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '36' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013185s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2097'[0m][0m SQL RUNTIME[[0;32m0.00022006s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2097'[0m][0m SQL RUNTIME[[0;32m0.00015807s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2557'[0m][0m SQL RUNTIME[[0;32m0.00042391s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '37' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012922s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2098'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2098'[0m][0m SQL RUNTIME[[0;32m0.00015712s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2558'[0m][0m SQL RUNTIME[[0;32m0.00044012s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '38' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012779s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2099'[0m][0m SQL RUNTIME[[0;32m0.00020003s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2099'[0m][0m SQL RUNTIME[[0;32m0.00015593s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2559'[0m][0m SQL RUNTIME[[0;32m0.00041294s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '39' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00014901s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2100'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2100'[0m][0m SQL RUNTIME[[0;32m0.00015497s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2560'[0m][0m SQL RUNTIME[[0;32m0.00041890s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '40' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012708s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2101'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2101'[0m][0m SQL RUNTIME[[0;32m0.00017715s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2561'[0m][0m SQL RUNTIME[[0;32m0.00044799s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '41' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2102'[0m][0m SQL RUNTIME[[0;32m0.00019979s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2102'[0m][0m SQL RUNTIME[[0;32m0.00015497s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2562'[0m][0m SQL RUNTIME[[0;32m0.00041389s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '42' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012708s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2103'[0m][0m SQL RUNTIME[[0;32m0.00020003s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2103'[0m][0m SQL RUNTIME[[0;32m0.00017595s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2563'[0m][0m SQL RUNTIME[[0;32m0.00041914s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '43' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012589s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2104'[0m][0m SQL RUNTIME[[0;32m0.00020599s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2104'[0m][0m SQL RUNTIME[[0;32m0.00016308s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2564'[0m][0m SQL RUNTIME[[0;32m0.00040889s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '44' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00012493s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2105'[0m][0m SQL RUNTIME[[0;32m0.00019789s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2105'[0m][0m SQL RUNTIME[[0;32m0.00015402s[0m][0m SQL[[0;33mUPDATE `ports_vlans` set `vlan` ='1',`baseport` ='',`priority` ='',`state` ='',`cost` ='' WHERE `port_vlan_id` = '2565'[0m][0m SQL RUNTIME[[0;32m0.00040603s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'baseport' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'priority' at row 1[0m [0;35m1366: Incorrect integer value: '' for column 'cost' at row 1[0m ][0m +---------+----------+------+---------------+-------+------+ | [37;1mifIndex[0m | [37;1mifDescr[0m | [37;1mVlan[0m | [37;1mSTP: Priority[0m | [37;1mState[0m | [37;1mCost[0m | +---------+----------+------+---------------+-------+------+ | 11 | Et1/1/1 | 1 | | | | | 12 | Et1/1/2 | 1 | | | | | 13 | Et1/1/3 | 1 | | | | | 14 | Et1/1/4 | 1 | | | | | 15 | Et1/1/5 | 1 | | | | | 16 | Et1/1/6 | 1 | | | | | 17 | Et1/1/7 | 1 | | | | | 18 | Et1/1/8 | 1 | | | | | 19 | Et1/1/9 | 1 | | | | | 20 | Et1/1/10 | 1 | | | | | 21 | Et1/1/11 | 1 | | | | | 22 | Et1/1/12 | 1 | | | | | 23 | Et1/1/13 | 1 | | | | | 24 | Et1/1/14 | 1 | | | | | 25 | Et1/1/15 | 1 | | | | | 26 | Et1/1/16 | 1 | | | | | 27 | Et1/1/17 | 1 | | | | | 28 | Et1/1/18 | 1 | | | | | 29 | Et1/1/19 | 1 | | | | | 30 | Et1/1/20 | 1 | | | | | 31 | Et1/1/21 | 1 | | | | | 32 | Et1/1/22 | 1 | | | | | 33 | Et1/1/23 | 1 | | | | | 34 | Et1/1/24 | 1 | | | | | 35 | Et1/1/25 | 1 | | | | | 36 | Et1/1/26 | 1 | | | | | 37 | Et1/1/27 | 1 | | | | | 38 | Et1/1/28 | 1 | | | | | 39 | Et1/1/29 | 1 | | | | | 40 | Et1/1/30 | 1 | | | | | 41 | Et1/1/31 | 1 | | | | | 42 | Et1/1/32 | 1 | | | | | 43 | Et1/1/33 | 1 | | | | | 44 | Et1/1/34 | 1 | | | | +---------+----------+------+---------------+-------+------+ Module [ vlans ] stats: 1[V.PU] [0;36m o [1;37mChanges [0m 1 unchanged [0;36m o [1;37mDuration [0m 0.237s [0;36m##### [1;37mModule Start: [1;31moids[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00029302s[0m][0m SQL[[0;33mSELECT * FROM `oids` WHERE `oid_autodiscover` = '1'[0m][0m SQL RUNTIME[[0;32m0.00014281s[0m][0m [0;36m o [1;37mDuration [0m 0.0009s [0;36m##### [1;37mModule Start: [1;31mcisco-vrf[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0004s [0;36m##### [1;37mModule Start: [1;31mip-addresses[0;36m #####[0m [0m [0;36m o [1;37mIP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAdEntIfIndex[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0146s[0m][0m STDOUT[ ipAdEntIfIndex.127.0.0.1 = 1 ipAdEntIfIndex.192.168.100.113 = 9 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAdEntNetMask[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0128s[0m][0m STDOUT[ ipAdEntNetMask.127.0.0.1 = 255.0.0.0 ipAdEntNetMask.192.168.100.113 = 255.255.255.0 ] SNMP STATUS[[0;32mTRUE[0m][0m Added 127.0.0.1 .Added 192.168.100.113 . CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAddressIfIndex[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0136s[0m][0m STDOUT[ ipAddressIfIndex.ipv4."127.0.0.1" = 1 ipAddressIfIndex.ipv4."192.168.100.113" = 9 ipAddressIfIndex.ipv4."255.168.100.255" = 9 ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = 1 ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:02:00:00:ff:fe:00:00:00" = 1 ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9c:40" = 9 ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9d:45" = 45 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAddressType[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0129s[0m][0m STDOUT[ ipAddressType.ipv4."127.0.0.1" = unicast ipAddressType.ipv4."192.168.100.113" = unicast ipAddressType.ipv4."255.168.100.255" = broadcast ipAddressType.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = unicast ipAddressType.ipv6."fe:80:00:00:00:00:00:00:02:00:00:ff:fe:00:00:00" = unicast ipAddressType.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9c:40" = unicast ipAddressType.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9d:45" = unicast ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAddressPrefix[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0127s[0m][0m STDOUT[ ipAddressPrefix.ipv4."127.0.0.1" = ipAddressPrefixOrigin.1.ipv4."127.0.0.0".8 ipAddressPrefix.ipv4."192.168.100.113" = ipAddressPrefixOrigin.9.ipv4."192.168.100.0".24 ipAddressPrefix.ipv4."255.168.100.255" = ipAddressPrefixOrigin.9.ipv4."255.168.100.0".24 ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128 ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:02:00:00:ff:fe:00:00:00" = ipAddressPrefixOrigin.1.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64 ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9c:40" = ipAddressPrefixOrigin.9.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64 ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9d:45" = ipAddressPrefixOrigin.45.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipAddressOrigin[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0127s[0m][0m STDOUT[ ipAddressOrigin.ipv4."127.0.0.1" = manual ipAddressOrigin.ipv4."192.168.100.113" = manual ipAddressOrigin.ipv4."255.168.100.255" = manual ipAddressOrigin.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = manual ipAddressOrigin.ipv6."fe:80:00:00:00:00:00:00:02:00:00:ff:fe:00:00:00" = linklayer ipAddressOrigin.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9c:40" = linklayer ipAddressOrigin.ipv6."fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:d3:9d:45" = linklayer ] SNMP STATUS[[0;32mTRUE[0m][0m Added 0000:0000:0000:0000:0000:0000:0000:0001 .Address fe80:0000:0000:0000:0200:00ff:fe00:0000/64 marked as invalid by type [link-local]. Address 'fe80:0000:0000:0000:0200:00ff:fe00:0000/64' skipped as invalid. Address fe80:0000:0000:0000:8e04:baff:fed3:9c40/64 marked as invalid by type [link-local]. Address 'fe80:0000:0000:0000:8e04:baff:fed3:9c40/64' skipped as invalid. Address fe80:0000:0000:0000:8e04:baff:fed3:9d45/64 marked as invalid by type [link-local]. Address 'fe80:0000:0000:0000:8e04:baff:fed3:9d45/64' skipped as invalid. [0;36m o [1;37mIPV6-MIB [0m SQL[[0;33mSELECT * FROM `ipv4_addresses`[0m [0;33m WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00030708s[0m][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013995s[0m][0m SQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'[0m][0m SQL RUNTIME[[0;32m0.00014114s[0m][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '9' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00013113s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2071'[0m][0m SQL RUNTIME[[0;32m0.00021911s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2071'[0m][0m SQL RUNTIME[[0;32m0.00015688s[0m][0m SQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.100.0/24'[0m][0m SQL RUNTIME[[0;32m0.00012493s[0m][0m SQL[[0;33mSELECT * FROM `ipv4_addresses`[0m [0;33m WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m SQL[[0;33mSELECT * FROM `ipv6_addresses`[0m [0;33m WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014877s[0m][0m SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1[0m][0m SQL RUNTIME[[0;32m0.00011706s[0m][0m SQL[[0;33mSELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128'[0m][0m SQL RUNTIME[[0;32m0.00011206s[0m][0m SQL[[0;33mSELECT * FROM `ipv6_addresses`[0m [0;33m WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014400s[0m][0m +---------+-----------+-------------+--------------------+---------------------+----------+--------+ | [37;1mifIndex[0m | [37;1mifDescr[0m | [37;1mIP: Version[0m | [37;1mAddress[0m | [37;1mNetwork[0m | [37;1mType[0m | [37;1mOrigin[0m | +---------+-----------+-------------+--------------------+---------------------+----------+--------+ | 1 | ... | IPv4 | 127.0.0.1/8 | 127.0.0.0/8 | loopback | | | 9 | mgmt1/1/1 | IPv4 | 192.168.100.113/24 | 192.168.100.0/24 | private | | | 1 | ... | IPv6 | ::1/128 | 0:0:0:0:0:0:0:1/128 | loopback | manual | +---------+-----------+-------------+--------------------+---------------------+----------+--------+ [0;36m o [1;37mChanges [0m 3 unchanged [0;36m o [1;37mDuration [0m 0.0986s [0;36m##### [1;37mModule Start: [1;31mprocessors[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '84' AND `processor_type` != 'ucd-old')[0m][0m SQL RUNTIME[[0;32m0.00019717s[0m][0m [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' hrDevice[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0253s[0m][0m STDOUT[ hrDeviceIndex.196608 = 196608 hrDeviceIndex.196609 = 196609 hrDeviceIndex.196610 = 196610 hrDeviceIndex.196611 = 196611 hrDeviceIndex.393232 = 393232 hrDeviceIndex.393280 = 393280 hrDeviceIndex.393296 = 393296 hrDeviceIndex.393312 = 393312 hrDeviceIndex.393328 = 393328 hrDeviceIndex.786432 = 786432 hrDeviceType.196608 = hrDeviceProcessor hrDeviceType.196609 = hrDeviceProcessor hrDeviceType.196610 = hrDeviceProcessor hrDeviceType.196611 = hrDeviceProcessor hrDeviceType.393232 = hrDeviceDiskStorage hrDeviceType.393280 = hrDeviceDiskStorage hrDeviceType.393296 = hrDeviceDiskStorage hrDeviceType.393312 = hrDeviceDiskStorage hrDeviceType.393328 = hrDeviceDiskStorage hrDeviceType.786432 = hrDeviceCoprocessor hrDeviceDescr.196608 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196609 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196610 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196611 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.393232 = SCSI disk (/dev/sda) hrDeviceDescr.393280 = LVM volume (OS10-CONFIG) hrDeviceDescr.393296 = LVM volume (OS10-SYSROOT1) hrDeviceDescr.393312 = LVM volume (OS10-SYSROOT2) hrDeviceDescr.393328 = LVM volume (OS10-LICENSE) hrDeviceDescr.786432 = Guessing that there's a floating point co-processor hrDeviceID.196608 = zeroDotZero hrDeviceID.196609 = zeroDotZero hrDeviceID.196610 = zeroDotZero hrDeviceID.196611 = zeroDotZero hrDeviceID.393232 = zeroDotZero hrDeviceID.393280 = zeroDotZero hrDeviceID.393296 = zeroDotZero hrDeviceID.393312 = zeroDotZero hrDeviceID.393328 = zeroDotZero hrDeviceID.786432 = zeroDotZero hrDeviceStatus.196608 = running hrDeviceStatus.196609 = running hrDeviceStatus.196610 = running hrDeviceStatus.196611 = running hrProcessorFrwID.196608 = zeroDotZero hrProcessorFrwID.196609 = zeroDotZero hrProcessorFrwID.196610 = zeroDotZero hrProcessorFrwID.196611 = zeroDotZero hrProcessorLoad.196608 = 8 hrProcessorLoad.196609 = 8 hrProcessorLoad.196610 = 10 hrProcessorLoad.196611 = 7 hrDiskStorageAccess.393232 = readWrite hrDiskStorageAccess.393280 = readWrite hrDiskStorageAccess.393296 = readWrite hrDiskStorageAccess.393312 = readWrite hrDiskStorageAccess.393328 = readWrite hrDiskStorageMedia.393232 = unknown hrDiskStorageMedia.393280 = unknown hrDiskStorageMedia.393296 = unknown hrDiskStorageMedia.393312 = unknown hrDiskStorageMedia.393328 = unknown hrDiskStorageRemoveble.393232 = false hrDiskStorageRemoveble.393280 = false hrDiskStorageRemoveble.393296 = false hrDiskStorageRemoveble.393312 = false hrDiskStorageRemoveble.393328 = false hrDiskStorageCapacity.393232 = 62522712 hrDiskStorageCapacity.393280 = 512000 hrDiskStorageCapacity.393296 = 30785536 hrDiskStorageCapacity.393312 = 30785536 hrDiskStorageCapacity.393328 = 32768 hrPartitionIndex.393232.1 = 1 hrPartitionIndex.393232.2 = 2 hrPartitionIndex.393232.3 = 3 hrPartitionIndex.393232.4 = 4 hrPartitionIndex.393280.1 = 1 hrPartitionIndex.393296.1 = 1 hrPartitionIndex.393312.1 = 1 hrPartitionIndex.393328.1 = 1 hrPartitionLabel.393232.1 = "/dev/sda1" hrPartitionLabel.393232.2 = "/dev/sda2" hrPartitionLabel.393232.3 = "/dev/sda3" hrPartitionLabel.393232.4 = "/dev/sda4" hrPartitionLabel.393280.1 = "/dev/mapper/OS10-CONFIG" hrPartitionLabel.393296.1 = "/dev/mapper/OS10-SYSROOT1" hrPartitionLabel.393312.1 = "/dev/mapper/OS10-SYSROOT2" hrPartitionLabel.393328.1 = "/dev/mapper/OS10-LICENSE" hrPartitionID.393232.1 = "0x801" hrPartitionID.393232.2 = "0x802" hrPartitionID.393232.3 = "0x803" hrPartitionID.393232.4 = "0x804" hrPartitionID.393280.1 = "0xf901" hrPartitionID.393296.1 = "0xf902" hrPartitionID.393312.1 = "0xf903" hrPartitionID.393328.1 = "0xf900" hrPartitionSize.393232.1 = -1 hrPartitionSize.393232.2 = 122835 hrPartitionSize.393232.3 = 6907 hrPartitionSize.393232.4 = -1 hrPartitionSize.393280.1 = 487652 hrPartitionSize.393296.1 = 30171172 hrPartitionSize.393312.1 = 30171084 hrPartitionSize.393328.1 = 27633 hrPartitionFSIndex.393232.1 = -1 hrPartitionFSIndex.393232.2 = 30 hrPartitionFSIndex.393232.3 = 29 hrPartitionFSIndex.393232.4 = -1 hrPartitionFSIndex.393280.1 = 32 hrPartitionFSIndex.393296.1 = 34 hrPartitionFSIndex.393312.1 = 1 hrPartitionFSIndex.393328.1 = 31 hrFSIndex.1 = 1 hrFSIndex.7 = 7 hrFSIndex.9 = 9 hrFSIndex.10 = 10 hrFSIndex.11 = 11 hrFSIndex.29 = 29 hrFSIndex.30 = 30 hrFSIndex.31 = 31 hrFSIndex.32 = 32 hrFSIndex.34 = 34 hrFSMountPoint.1 = "/" hrFSMountPoint.7 = "/run" hrFSMountPoint.9 = "/dev/shm" hrFSMountPoint.10 = "/run/lock" hrFSMountPoint.11 = "/sys/fs/cgroup" hrFSMountPoint.29 = "/mnt/boot" hrFSMountPoint.30 = "/mnt/onie-boot" hrFSMountPoint.31 = "/mnt/license" hrFSMountPoint.32 = "/config" hrFSMountPoint.34 = "/alt" hrFSRemoteMountPoint.1 = "" hrFSRemoteMountPoint.7 = "" hrFSRemoteMountPoint.9 = "" hrFSRemoteMountPoint.10 = "" hrFSRemoteMountPoint.11 = "" hrFSRemoteMountPoint.29 = "" hrFSRemoteMountPoint.30 = "" hrFSRemoteMountPoint.31 = "" hrFSRemoteMountPoint.32 = "" hrFSRemoteMountPoint.34 = "" hrFSType.1 = hrFSLinuxExt2 hrFSType.7 = hrFSOther hrFSType.9 = hrFSOther hrFSType.10 = hrFSOther hrFSType.11 = hrFSOther hrFSType.29 = hrFSLinuxExt2 hrFSType.30 = hrFSLinuxExt2 hrFSType.31 = hrFSLinuxExt2 hrFSType.32 = hrFSLinuxExt2 hrFSType.34 = hrFSLinuxExt2 hrFSAccess.1 = readWrite hrFSAccess.7 = readWrite hrFSAccess.9 = readWrite hrFSAccess.10 = readWrite hrFSAccess.11 = readOnly hrFSAccess.29 = readWrite hrFSAccess.30 = readWrite hrFSAccess.31 = readOnly hrFSAccess.32 = readWrite hrFSAccess.34 = readOnly hrFSBootable.1 = true hrFSBootable.7 = false hrFSBootable.9 = false hrFSBootable.10 = false hrFSBootable.11 = false hrFSBootable.29 = false hrFSBootable.30 = false hrFSBootable.31 = false hrFSBootable.32 = false hrFSBootable.34 = false hrFSStorageIndex.1 = 31 hrFSStorageIndex.7 = 37 hrFSStorageIndex.9 = 39 hrFSStorageIndex.10 = 40 hrFSStorageIndex.11 = 41 hrFSStorageIndex.29 = 59 hrFSStorageIndex.30 = 60 hrFSStorageIndex.31 = 61 hrFSStorageIndex.32 = 62 hrFSStorageIndex.34 = 64 hrFSLastFullBackupDate.1 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.7 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.9 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.10 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.11 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.29 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.30 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.31 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.32 = 0-1-1,0:0:0.0 hrFSLastFullBackupDate.34 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.1 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.7 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.9 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.10 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.11 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.29 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.30 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.31 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.32 = 0-1-1,0:0:0.0 hrFSLastPartialBackupDate.34 = 0-1-1,0:0:0.0 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' hrProcessorLoad[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0116s[0m][0m STDOUT[ hrProcessorLoad.196608 = 8 hrProcessorLoad.196609 = 8 hrProcessorLoad.196610 = 10 hrProcessorLoad.196611 = 7 ] SNMP STATUS[[0;32mTRUE[0m][0m 84 -> .1.3.6.1.2.1.25.3.3.1.2.196608, 196608, hr, Intel Atom C3538 @ 2.10GHz, 1, 8, , 196608 SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84' AND `processor_index` = '196608' AND `processor_type` = 'hr'[0m][0m SQL RUNTIME[[0;32m0.00027585s[0m][0m 84 -> .1.3.6.1.2.1.25.3.3.1.2.196609, 196609, hr, Intel Atom C3538 @ 2.10GHz, 1, 8, , 196609 SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84' AND `processor_index` = '196609' AND `processor_type` = 'hr'[0m][0m SQL RUNTIME[[0;32m0.00017595s[0m][0m 84 -> .1.3.6.1.2.1.25.3.3.1.2.196610, 196610, hr, Intel Atom C3538 @ 2.10GHz, 1, 10, , 196610 SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84' AND `processor_index` = '196610' AND `processor_type` = 'hr'[0m][0m SQL RUNTIME[[0;32m0.00016809s[0m][0m 84 -> .1.3.6.1.2.1.25.3.3.1.2.196611, 196611, hr, Intel Atom C3538 @ 2.10GHz, 1, 7, , 196611 SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84' AND `processor_index` = '196611' AND `processor_type` = 'hr'[0m][0m SQL RUNTIME[[0;32m0.00016594s[0m][0m 84 -> 1, 1, hr-average, Average, 1, , , SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84' AND `processor_index` = '1' AND `processor_type` = 'hr-average'[0m][0m SQL RUNTIME[[0;32m0.00016713s[0m][0m SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '84' AND `processor_type` = 'ucd-old')[0m][0m SQL RUNTIME[[0;32m0.00015688s[0m][0m [0;36m o [1;37mDELL-NETWORKING-CHASSIS-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetCpuUtil5Min[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0178s[0m][0m STDOUT[ dellNetCpuUtil5Min = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00021696s[0m][0m 196608 -> hr 196609 -> hr 196610 -> hr 196611 -> hr 1 -> hr-average [1;44;96m > $valid['processor'][0m[44;36m /opt/observium/includes/discovery/processors.inc.php:164 [0m array( [hr] => array( [196608] => int(1) [196609] => int(1) [196610] => int(1) [196611] => int(1) ) [hr-average] => array( [1] => int(1) ) ) [0;36m o [1;37mChanges [0m 5 unchanged [0;36m o [1;37mDuration [0m 0.0629s [0;36m##### [1;37mModule Start: [1;31mmempools[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0094s[0m][0m STDOUT[ memTotalReal.0 = 16375556 memAvailReal.0 = 14025892 memBuffer.0 = 24272 memCached.0 = 465120 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' versionTag.0 versionCDate.0 versionConfigureOptions.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0095s[0m][0m STDOUT[ versionTag.0 = 5.7.3 versionCDate.0 = Mon Jul 13 12:26:58 2020 versionConfigureOptions.0 = '--build=x86_64-linux-gnu' '--includedir=${prefix}/include' '--mandir=${prefix}/share/man' '--infodir=${prefix}/share/info' '--localstatedir=/var' '--disable-silent-rules' '--libdir=${prefix}/lib/x86_64-linux-gnu' '--libexecdir=${prefix}/lib/x86_64-linux-gnu' '--disable-maintainer-mode' '--disable-dependency-tracking' '--prefix=/usr' '--sysconfdir=/etc' '--mandir=/usr/share/man' '--with-persistent-directory=/var/lib/snmp' '--enable-ucd-snmp-compatibility' '--enable-shared' '--with-cflags=-g -O2 -fdebug-prefix-map=/build/workspace/debian/stretch/x86_64/build/open-source-netsnmp/net-snmp-5.7.3+dfsg=. -fstack-protector-strong -Wformat -Werror=format-security -DNETSNMP_USE_INLINE' '--enable-ipv6' '--with-ldflags=-Wl,-z,relro' '--with-perl-modules=INSTALLDIRS=vendor' '--enable-as-needed' '--with-logfile=none' '--without-rpm' '--with-libwrap' '--with-openssl' '--without-dmalloc' '--without-efence' '--without-rsaref' '--with-sys-contact=root' '--with-sys-location=Unknown' '--with-mib-modules=ucd-snmp/dlmod mibII mi ] SNMP STATUS[[0;32mTRUE[0m][0m 84 -> 0, UCD-SNMP-MIB::, Physical Memory, 1, 16768569344, 1904918528 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '84' AND `mempool_index` = '0' AND `mempool_mib` = 'UCD-SNMP-MIB'[0m][0m SQL RUNTIME[[0;32m0.00027299s[0m][0m [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' hrStorageEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0146s[0m][0m STDOUT[ hrStorageIndex.1 = 1 hrStorageIndex.3 = 3 hrStorageIndex.6 = 6 hrStorageIndex.7 = 7 hrStorageIndex.8 = 8 hrStorageIndex.10 = 10 hrStorageIndex.31 = 31 hrStorageIndex.37 = 37 hrStorageIndex.39 = 39 hrStorageIndex.40 = 40 hrStorageIndex.41 = 41 hrStorageIndex.59 = 59 hrStorageIndex.60 = 60 hrStorageIndex.61 = 61 hrStorageIndex.62 = 62 hrStorageIndex.64 = 64 hrStorageType.1 = hrStorageRam hrStorageType.3 = hrStorageVirtualMemory hrStorageType.6 = hrStorageOther hrStorageType.7 = hrStorageOther hrStorageType.8 = hrStorageOther hrStorageType.10 = hrStorageVirtualMemory hrStorageType.31 = hrStorageFixedDisk hrStorageType.37 = hrStorageFixedDisk hrStorageType.39 = hrStorageFixedDisk hrStorageType.40 = hrStorageFixedDisk hrStorageType.41 = hrStorageFixedDisk hrStorageType.59 = hrStorageFixedDisk hrStorageType.60 = hrStorageFixedDisk hrStorageType.61 = hrStorageFixedDisk hrStorageType.62 = hrStorageFixedDisk hrStorageType.64 = hrStorageFixedDisk hrStorageDescr.1 = Physical memory hrStorageDescr.3 = Virtual memory hrStorageDescr.6 = Memory buffers hrStorageDescr.7 = Cached memory hrStorageDescr.8 = Shared memory hrStorageDescr.10 = Swap space hrStorageDescr.31 = / hrStorageDescr.37 = /run hrStorageDescr.39 = /dev/shm hrStorageDescr.40 = /run/lock hrStorageDescr.41 = /sys/fs/cgroup hrStorageDescr.59 = /mnt/boot hrStorageDescr.60 = /mnt/onie-boot hrStorageDescr.61 = /mnt/license hrStorageDescr.62 = /config hrStorageDescr.64 = /alt hrStorageAllocationUnits.1 = 1024 hrStorageAllocationUnits.3 = 1024 hrStorageAllocationUnits.6 = 1024 hrStorageAllocationUnits.7 = 1024 hrStorageAllocationUnits.8 = 1024 hrStorageAllocationUnits.10 = 1024 hrStorageAllocationUnits.31 = 4096 hrStorageAllocationUnits.37 = 4096 hrStorageAllocationUnits.39 = 4096 hrStorageAllocationUnits.40 = 4096 hrStorageAllocationUnits.41 = 4096 hrStorageAllocationUnits.59 = 1024 hrStorageAllocationUnits.60 = 1024 hrStorageAllocationUnits.61 = 1024 hrStorageAllocationUnits.62 = 1024 hrStorageAllocationUnits.64 = 4096 hrStorageSize.1 = 16375556 hrStorageSize.3 = 18013108 hrStorageSize.6 = 16375556 hrStorageSize.7 = 465120 hrStorageSize.8 = 5224 hrStorageSize.10 = 1637552 hrStorageSize.31 = 7542771 hrStorageSize.37 = 409389 hrStorageSize.39 = 2046944 hrStorageSize.40 = 1280 hrStorageSize.41 = 2046944 hrStorageSize.59 = 6907 hrStorageSize.60 = 122835 hrStorageSize.61 = 27633 hrStorageSize.62 = 487652 hrStorageSize.64 = 7542793 hrStorageUsed.1 = 2349664 hrStorageUsed.3 = 2349664 hrStorageUsed.6 = 24272 hrStorageUsed.7 = 465120 hrStorageUsed.8 = 5224 hrStorageUsed.10 = 0 hrStorageUsed.31 = 466561 hrStorageUsed.37 = 1299 hrStorageUsed.39 = 6 hrStorageUsed.40 = 0 hrStorageUsed.41 = 0 hrStorageUsed.59 = 2902 hrStorageUsed.60 = 22715 hrStorageUsed.61 = 399 hrStorageUsed.62 = 3687 hrStorageUsed.64 = 609590 ] SNMP STATUS[[0;32mTRUE[0m][0m 84 -> 3, HOST-RESOURCES-MIB::, Virtual memory, 1024, 18013108, 2349664 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '84' AND `mempool_index` = '3' AND `mempool_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00027204s[0m][0m 84 -> 6, HOST-RESOURCES-MIB::, Memory buffers, 1024, 16375556, 24272 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '84' AND `mempool_index` = '6' AND `mempool_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00017309s[0m][0m 84 -> 10, HOST-RESOURCES-MIB::, Swap space, 1024, 1637552, 0 SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '84' AND `mempool_index` = '10' AND `mempool_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00016809s[0m][0m [0;36m o [1;37mDELL-NETWORKING-CHASSIS-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetCpuUtilMemUsage[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.018s[0m][0m STDOUT[ dellNetCpuUtilMemUsage = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetProcessorMemSize[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0181s[0m][0m STDOUT[ dellNetProcessorMemSize = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00041890s[0m][0m 0 -> UCD-SNMP-MIB 3 -> HOST-RESOURCES-MIB 6 -> HOST-RESOURCES-MIB 10 -> HOST-RESOURCES-MIB [1;44;96m > $valid['mempool'][0m[44;36m /opt/observium/includes/discovery/mempools.inc.php:216 [0m array( [UCD-SNMP-MIB] => array( [0] => int(1) ) [HOST-RESOURCES-MIB] => array( [3] => int(1) [6] => int(1) [10] => int(1) ) ) [0;36m o [1;37mChanges [0m 4 unchanged [0;36m o [1;37mDuration [0m 0.0795s [0;36m##### [1;37mModule Start: [1;31minventory[0;36m #####[0m [0m [0;36m o [1;37mHOST-RESOURCES-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' hrDeviceEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0161s[0m][0m STDOUT[ hrDeviceIndex.196608 = 196608 hrDeviceIndex.196609 = 196609 hrDeviceIndex.196610 = 196610 hrDeviceIndex.196611 = 196611 hrDeviceIndex.393232 = 393232 hrDeviceIndex.393280 = 393280 hrDeviceIndex.393296 = 393296 hrDeviceIndex.393312 = 393312 hrDeviceIndex.393328 = 393328 hrDeviceIndex.786432 = 786432 hrDeviceType.196608 = hrDeviceProcessor hrDeviceType.196609 = hrDeviceProcessor hrDeviceType.196610 = hrDeviceProcessor hrDeviceType.196611 = hrDeviceProcessor hrDeviceType.393232 = hrDeviceDiskStorage hrDeviceType.393280 = hrDeviceDiskStorage hrDeviceType.393296 = hrDeviceDiskStorage hrDeviceType.393312 = hrDeviceDiskStorage hrDeviceType.393328 = hrDeviceDiskStorage hrDeviceType.786432 = hrDeviceCoprocessor hrDeviceDescr.196608 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196609 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196610 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.196611 = GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz hrDeviceDescr.393232 = SCSI disk (/dev/sda) hrDeviceDescr.393280 = LVM volume (OS10-CONFIG) hrDeviceDescr.393296 = LVM volume (OS10-SYSROOT1) hrDeviceDescr.393312 = LVM volume (OS10-SYSROOT2) hrDeviceDescr.393328 = LVM volume (OS10-LICENSE) hrDeviceDescr.786432 = Guessing that there's a floating point co-processor hrDeviceID.196608 = zeroDotZero hrDeviceID.196609 = zeroDotZero hrDeviceID.196610 = zeroDotZero hrDeviceID.196611 = zeroDotZero hrDeviceID.393232 = zeroDotZero hrDeviceID.393280 = zeroDotZero hrDeviceID.393296 = zeroDotZero hrDeviceID.393312 = zeroDotZero hrDeviceID.393328 = zeroDotZero hrDeviceID.786432 = zeroDotZero hrDeviceStatus.196608 = running hrDeviceStatus.196609 = running hrDeviceStatus.196610 = running hrDeviceStatus.196611 = running ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' hrProcessorEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0116s[0m][0m STDOUT[ hrProcessorFrwID.196608 = zeroDotZero hrProcessorFrwID.196609 = zeroDotZero hrProcessorFrwID.196610 = zeroDotZero hrProcessorFrwID.196611 = zeroDotZero hrProcessorLoad.196608 = 8 hrProcessorLoad.196609 = 8 hrProcessorLoad.196610 = 10 hrProcessorLoad.196611 = 7 ] SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '196608')[0m][0m SQL RUNTIME[[0;32m0.00030994s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceProcessor',`hrDeviceDescr` ='GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz',`hrDeviceStatus` ='running',`hrDeviceErrors` ='',`hrProcessorLoad` ='8' WHERE device_id = '84' AND hrDeviceIndex = '196608'[0m][0m SQL RUNTIME[[0;32m0.00058198s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 1[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '196609')[0m][0m SQL RUNTIME[[0;32m0.00015211s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceProcessor',`hrDeviceDescr` ='GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz',`hrDeviceStatus` ='running',`hrDeviceErrors` ='',`hrProcessorLoad` ='8' WHERE device_id = '84' AND hrDeviceIndex = '196609'[0m][0m SQL RUNTIME[[0;32m0.00045919s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 2[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '196610')[0m][0m SQL RUNTIME[[0;32m0.00014997s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceProcessor',`hrDeviceDescr` ='GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz',`hrDeviceStatus` ='running',`hrDeviceErrors` ='',`hrProcessorLoad` ='10' WHERE device_id = '84' AND hrDeviceIndex = '196610'[0m][0m SQL RUNTIME[[0;32m0.00046086s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 3[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '196611')[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceProcessor',`hrDeviceDescr` ='GenuineIntel: Intel(R) Atom(TM) CPU C3538 @ 2.10GHz',`hrDeviceStatus` ='running',`hrDeviceErrors` ='',`hrProcessorLoad` ='7' WHERE device_id = '84' AND hrDeviceIndex = '196611'[0m][0m SQL RUNTIME[[0;32m0.00043702s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 4[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '393232')[0m][0m SQL RUNTIME[[0;32m0.00017810s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='SCSI disk (/dev/sda)',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '393232'[0m][0m SQL RUNTIME[[0;32m0.00044894s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 5[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '393280')[0m][0m SQL RUNTIME[[0;32m0.00018597s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='LVM volume (OS10-CONFIG)',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '393280'[0m][0m SQL RUNTIME[[0;32m0.00043917s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 6[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '393296')[0m][0m SQL RUNTIME[[0;32m0.00014782s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='LVM volume (OS10-SYSROOT1)',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '393296'[0m][0m SQL RUNTIME[[0;32m0.00043392s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 7[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '393312')[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='LVM volume (OS10-SYSROOT2)',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '393312'[0m][0m SQL RUNTIME[[0;32m0.00046396s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 8[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '393328')[0m][0m SQL RUNTIME[[0;32m0.00014901s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceDiskStorage',`hrDeviceDescr` ='LVM volume (OS10-LICENSE)',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '393328'[0m][0m SQL RUNTIME[[0;32m0.00051689s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 9[0m ][0m . SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `hrDevice` WHERE `device_id` = '84' AND `hrDeviceIndex` = '786432')[0m][0m SQL RUNTIME[[0;32m0.00014782s[0m][0m SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceCoprocessor',`hrDeviceDescr` ='Guessing that there\'s a floating point co-processor',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` =NULL WHERE device_id = '84' AND hrDeviceIndex = '786432'[0m][0m SQL RUNTIME[[0;32m0.00042892s[0m] SQL WARNINGS[ [0;35m1366: Incorrect integer value: '' for column 'hrDeviceErrors' at row 10[0m ][0m . SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00016189s[0m][0m [0;36m o [1;37mENTITY-MIB [0m ENTITY-MIB CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'ssw006':'161' entPhysicalEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.176s[0m][0m STDOUT[ entPhysicalDescr.1 = entPhysicalDescr.2 = DellEMC Networking S5232F-ON Chassis entPhysicalDescr.3 = S5232F-ON 32x100GbE QSFP28, 2x10GbE SFP28 Interface Module entPhysicalDescr.4 = Node:1 Unit:1 Port:1 Capacity:100GIGE entPhysicalDescr.5 = Node:1 Unit:1 Port:2 Capacity:100GIGE entPhysicalDescr.6 = Node:1 Unit:1 Port:3 Capacity:100GIGE entPhysicalDescr.7 = Node:1 Unit:1 Port:4 Capacity:100GIGE entPhysicalDescr.8 = Node:1 Unit:1 Port:5 Capacity:100GIGE entPhysicalDescr.9 = Node:1 Unit:1 Port:6 Capacity:100GIGE entPhysicalDescr.10 = Node:1 Unit:1 Port:7 Capacity:100GIGE entPhysicalDescr.11 = Node:1 Unit:1 Port:8 Capacity:100GIGE entPhysicalDescr.12 = Node:1 Unit:1 Port:9 Capacity:100GIGE entPhysicalDescr.13 = Node:1 Unit:1 Port:10 Capacity:100GIGE entPhysicalDescr.14 = Node:1 Unit:1 Port:11 Capacity:100GIGE entPhysicalDescr.15 = Node:1 Unit:1 Port:12 Capacity:100GIGE entPhysicalDescr.16 = Node:1 Unit:1 Port:13 Capacity:100GIGE entPhysicalDescr.17 = Node:1 Unit:1 Port:14 Capacity:100GIGE entPhysicalDescr.18 = Node:1 Unit:1 Port:15 Capacity:100GIGE entPhysicalDescr.19 = Node:1 Unit:1 Port:16 Capacity:100GIGE entPhysicalDescr.20 = Node:1 Unit:1 Port:17 Capacity:100GIGE entPhysicalDescr.21 = Node:1 Unit:1 Port:18 Capacity:100GIGE entPhysicalDescr.22 = Node:1 Unit:1 Port:19 Capacity:100GIGE entPhysicalDescr.23 = Node:1 Unit:1 Port:20 Capacity:100GIGE entPhysicalDescr.24 = Node:1 Unit:1 Port:21 Capacity:100GIGE entPhysicalDescr.25 = Node:1 Unit:1 Port:22 Capacity:100GIGE entPhysicalDescr.26 = Node:1 Unit:1 Port:23 Capacity:100GIGE entPhysicalDescr.27 = Node:1 Unit:1 Port:24 Capacity:100GIGE entPhysicalDescr.28 = Node:1 Unit:1 Port:25 Capacity:100GIGE entPhysicalDescr.29 = Node:1 Unit:1 Port:26 Capacity:100GIGE entPhysicalDescr.30 = Node:1 Unit:1 Port:27 Capacity:100GIGE entPhysicalDescr.31 = Node:1 Unit:1 Port:28 Capacity:100GIGE entPhysicalDescr.32 = Node:1 Unit:1 Port:29 Capacity:100GIGE entPhysicalDescr.33 = Node:1 Unit:1 Port:30 Capacity:100GIGE entPhysicalDescr.34 = Node:1 Unit:1 Port:31 Capacity:100GIGE entPhysicalDescr.35 = Node:1 Unit:1 Port:32 Capacity:100GIGE entPhysicalDescr.36 = Node:1 Unit:1 Port:33 Capacity:10GIGE entPhysicalDescr.37 = Node:1 Unit:1 Port:34 Capacity:10GIGE entPhysicalDescr.38 = S5232F-ON Fan Tray Container entPhysicalDescr.39 = S5232F-ON Fan Tray Module 1 entPhysicalDescr.40 = S5232F-ON Fan Tray Module 2 entPhysicalDescr.41 = S5232F-ON Fan Tray Module 3 entPhysicalDescr.42 = S5232F-ON Fan Tray Module 4 entPhysicalDescr.43 = S5232F-ON Power Supply Unit Container entPhysicalDescr.44 = S5232F-ON Power Supply Module 1 entPhysicalDescr.45 = S5232F-ON Power Supply Module 2 entPhysicalVendorType.1 = zeroDotZero.0 entPhysicalVendorType.2 = zeroDotZero.0 entPhysicalVendorType.3 = zeroDotZero.0 entPhysicalVendorType.4 = zeroDotZero.0 entPhysicalVendorType.5 = zeroDotZero.0 entPhysicalVendorType.6 = zeroDotZero.0 entPhysicalVendorType.7 = zeroDotZero.0 entPhysicalVendorType.8 = zeroDotZero.0 entPhysicalVendorType.9 = zeroDotZero.0 entPhysicalVendorType.10 = zeroDotZero.0 entPhysicalVendorType.11 = zeroDotZero.0 entPhysicalVendorType.12 = zeroDotZero.0 entPhysicalVendorType.13 = zeroDotZero.0 entPhysicalVendorType.14 = zeroDotZero.0 entPhysicalVendorType.15 = zeroDotZero.0 entPhysicalVendorType.16 = zeroDotZero.0 entPhysicalVendorType.17 = zeroDotZero.0 entPhysicalVendorType.18 = zeroDotZero.0 entPhysicalVendorType.19 = zeroDotZero.0 entPhysicalVendorType.20 = zeroDotZero.0 entPhysicalVendorType.21 = zeroDotZero.0 entPhysicalVendorType.22 = zeroDotZero.0 entPhysicalVendorType.23 = zeroDotZero.0 entPhysicalVendorType.24 = zeroDotZero.0 entPhysicalVendorType.25 = zeroDotZero.0 entPhysicalVendorType.26 = zeroDotZero.0 entPhysicalVendorType.27 = zeroDotZero.0 entPhysicalVendorType.28 = zeroDotZero.0 entPhysicalVendorType.29 = zeroDotZero.0 entPhysicalVendorType.30 = zeroDotZero.0 entPhysicalVendorType.31 = zeroDotZero.0 entPhysicalVendorType.32 = zeroDotZero.0 entPhysicalVendorType.33 = zeroDotZero.0 entPhysicalVendorType.34 = zeroDotZero.0 entPhysicalVendorType.35 = zeroDotZero.0 entPhysicalVendorType.36 = zeroDotZero.0 entPhysicalVendorType.37 = zeroDotZero.0 entPhysicalVendorType.38 = zeroDotZero.0 entPhysicalVendorType.39 = zeroDotZero.0 entPhysicalVendorType.40 = zeroDotZero.0 entPhysicalVendorType.41 = zeroDotZero.0 entPhysicalVendorType.42 = zeroDotZero.0 entPhysicalVendorType.43 = zeroDotZero.0 entPhysicalVendorType.44 = zeroDotZero.0 entPhysicalVendorType.45 = zeroDotZero.0 entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 2 entPhysicalContainedIn.4 = 3 entPhysicalContainedIn.5 = 3 entPhysicalContainedIn.6 = 3 entPhysicalContainedIn.7 = 3 entPhysicalContainedIn.8 = 3 entPhysicalContainedIn.9 = 3 entPhysicalContainedIn.10 = 3 entPhysicalContainedIn.11 = 3 entPhysicalContainedIn.12 = 3 entPhysicalContainedIn.13 = 3 entPhysicalContainedIn.14 = 3 entPhysicalContainedIn.15 = 3 entPhysicalContainedIn.16 = 3 entPhysicalContainedIn.17 = 3 entPhysicalContainedIn.18 = 3 entPhysicalContainedIn.19 = 3 entPhysicalContainedIn.20 = 3 entPhysicalContainedIn.21 = 3 entPhysicalContainedIn.22 = 3 entPhysicalContainedIn.23 = 3 entPhysicalContainedIn.24 = 3 entPhysicalContainedIn.25 = 3 entPhysicalContainedIn.26 = 3 entPhysicalContainedIn.27 = 3 entPhysicalContainedIn.28 = 3 entPhysicalContainedIn.29 = 3 entPhysicalContainedIn.30 = 3 entPhysicalContainedIn.31 = 3 entPhysicalContainedIn.32 = 3 entPhysicalContainedIn.33 = 3 entPhysicalContainedIn.34 = 3 entPhysicalContainedIn.35 = 3 entPhysicalContainedIn.36 = 3 entPhysicalContainedIn.37 = 3 entPhysicalContainedIn.38 = 2 entPhysicalContainedIn.39 = 38 entPhysicalContainedIn.40 = 38 entPhysicalContainedIn.41 = 38 entPhysicalContainedIn.42 = 38 entPhysicalContainedIn.43 = 2 entPhysicalContainedIn.44 = 43 entPhysicalContainedIn.45 = 43 entPhysicalClass.1 = stack entPhysicalClass.2 = chassis entPhysicalClass.3 = module entPhysicalClass.4 = port entPhysicalClass.5 = port entPhysicalClass.6 = port entPhysicalClass.7 = port entPhysicalClass.8 = port entPhysicalClass.9 = port entPhysicalClass.10 = port entPhysicalClass.11 = port entPhysicalClass.12 = port entPhysicalClass.13 = port entPhysicalClass.14 = port entPhysicalClass.15 = port entPhysicalClass.16 = port entPhysicalClass.17 = port entPhysicalClass.18 = port entPhysicalClass.19 = port entPhysicalClass.20 = port entPhysicalClass.21 = port entPhysicalClass.22 = port entPhysicalClass.23 = port entPhysicalClass.24 = port entPhysicalClass.25 = port entPhysicalClass.26 = port entPhysicalClass.27 = port entPhysicalClass.28 = port entPhysicalClass.29 = port entPhysicalClass.30 = port entPhysicalClass.31 = port entPhysicalClass.32 = port entPhysicalClass.33 = port entPhysicalClass.34 = port entPhysicalClass.35 = port entPhysicalClass.36 = port entPhysicalClass.37 = port entPhysicalClass.38 = container entPhysicalClass.39 = module entPhysicalClass.40 = module entPhysicalClass.41 = module entPhysicalClass.42 = module entPhysicalClass.43 = container entPhysicalClass.44 = module entPhysicalClass.45 = module entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 1 entPhysicalParentRelPos.3 = 1 entPhysicalParentRelPos.4 = 1 entPhysicalParentRelPos.5 = 2 entPhysicalParentRelPos.6 = 3 entPhysicalParentRelPos.7 = 4 entPhysicalParentRelPos.8 = 5 entPhysicalParentRelPos.9 = 6 entPhysicalParentRelPos.10 = 7 entPhysicalParentRelPos.11 = 8 entPhysicalParentRelPos.12 = 9 entPhysicalParentRelPos.13 = 10 entPhysicalParentRelPos.14 = 11 entPhysicalParentRelPos.15 = 12 entPhysicalParentRelPos.16 = 13 entPhysicalParentRelPos.17 = 14 entPhysicalParentRelPos.18 = 15 entPhysicalParentRelPos.19 = 16 entPhysicalParentRelPos.20 = 17 entPhysicalParentRelPos.21 = 18 entPhysicalParentRelPos.22 = 19 entPhysicalParentRelPos.23 = 20 entPhysicalParentRelPos.24 = 21 entPhysicalParentRelPos.25 = 22 entPhysicalParentRelPos.26 = 23 entPhysicalParentRelPos.27 = 24 entPhysicalParentRelPos.28 = 25 entPhysicalParentRelPos.29 = 26 entPhysicalParentRelPos.30 = 27 entPhysicalParentRelPos.31 = 28 entPhysicalParentRelPos.32 = 29 entPhysicalParentRelPos.33 = 30 entPhysicalParentRelPos.34 = 31 entPhysicalParentRelPos.35 = 32 entPhysicalParentRelPos.36 = 33 entPhysicalParentRelPos.37 = 34 entPhysicalParentRelPos.38 = 2 entPhysicalParentRelPos.39 = 1 entPhysicalParentRelPos.40 = 2 entPhysicalParentRelPos.41 = 3 entPhysicalParentRelPos.42 = 4 entPhysicalParentRelPos.43 = 3 entPhysicalParentRelPos.44 = 1 entPhysicalParentRelPos.45 = 2 entPhysicalName.1 = Stack entPhysicalName.2 = Unit 1 entPhysicalName.3 = Interface Module 1 entPhysicalName.4 = phy-eth1/1/1 entPhysicalName.5 = phy-eth1/1/2 entPhysicalName.6 = phy-eth1/1/3 entPhysicalName.7 = phy-eth1/1/4 entPhysicalName.8 = phy-eth1/1/5 entPhysicalName.9 = phy-eth1/1/6 entPhysicalName.10 = phy-eth1/1/7 entPhysicalName.11 = phy-eth1/1/8 entPhysicalName.12 = phy-eth1/1/9 entPhysicalName.13 = phy-eth1/1/10 entPhysicalName.14 = phy-eth1/1/11 entPhysicalName.15 = phy-eth1/1/12 entPhysicalName.16 = phy-eth1/1/13 entPhysicalName.17 = phy-eth1/1/14 entPhysicalName.18 = phy-eth1/1/15 entPhysicalName.19 = phy-eth1/1/16 entPhysicalName.20 = phy-eth1/1/17 entPhysicalName.21 = phy-eth1/1/18 entPhysicalName.22 = phy-eth1/1/19 entPhysicalName.23 = phy-eth1/1/20 entPhysicalName.24 = phy-eth1/1/21 entPhysicalName.25 = phy-eth1/1/22 entPhysicalName.26 = phy-eth1/1/23 entPhysicalName.27 = phy-eth1/1/24 entPhysicalName.28 = phy-eth1/1/25 entPhysicalName.29 = phy-eth1/1/26 entPhysicalName.30 = phy-eth1/1/27 entPhysicalName.31 = phy-eth1/1/28 entPhysicalName.32 = phy-eth1/1/29 entPhysicalName.33 = phy-eth1/1/30 entPhysicalName.34 = phy-eth1/1/31 entPhysicalName.35 = phy-eth1/1/32 entPhysicalName.36 = phy-eth1/1/33 entPhysicalName.37 = phy-eth1/1/34 entPhysicalName.38 = Fan Tray Container entPhysicalName.39 = Fan Tray Module 1 entPhysicalName.40 = Fan Tray Module 2 entPhysicalName.41 = Fan Tray Module 3 entPhysicalName.42 = Fan Tray Module 4 entPhysicalName.43 = Power Supply Unit Container entPhysicalName.44 = Power Supply Module 1 entPhysicalName.45 = Power Supply Module 2 entPhysicalHardwareRev.1 = entPhysicalHardwareRev.2 = A04 entPhysicalHardwareRev.3 = A04 entPhysicalHardwareRev.4 = entPhysicalHardwareRev.5 = entPhysicalHardwareRev.6 = entPhysicalHardwareRev.7 = entPhysicalHardwareRev.8 = entPhysicalHardwareRev.9 = entPhysicalHardwareRev.10 = entPhysicalHardwareRev.11 = entPhysicalHardwareRev.12 = entPhysicalHardwareRev.13 = entPhysicalHardwareRev.14 = entPhysicalHardwareRev.15 = entPhysicalHardwareRev.16 = entPhysicalHardwareRev.17 = entPhysicalHardwareRev.18 = entPhysicalHardwareRev.19 = entPhysicalHardwareRev.20 = entPhysicalHardwareRev.21 = entPhysicalHardwareRev.22 = entPhysicalHardwareRev.23 = entPhysicalHardwareRev.24 = entPhysicalHardwareRev.25 = entPhysicalHardwareRev.26 = entPhysicalHardwareRev.27 = entPhysicalHardwareRev.28 = entPhysicalHardwareRev.29 = entPhysicalHardwareRev.30 = entPhysicalHardwareRev.31 = entPhysicalHardwareRev.32 = entPhysicalHardwareRev.33 = entPhysicalHardwareRev.34 = entPhysicalHardwareRev.35 = entPhysicalHardwareRev.36 = entPhysicalHardwareRev.37 = entPhysicalHardwareRev.38 = entPhysicalHardwareRev.39 = A00 entPhysicalHardwareRev.40 = A00 entPhysicalHardwareRev.41 = A00 entPhysicalHardwareRev.42 = A00 entPhysicalHardwareRev.43 = entPhysicalHardwareRev.44 = A00 entPhysicalHardwareRev.45 = A00 entPhysicalFirmwareRev.1 = entPhysicalFirmwareRev.2 = entPhysicalFirmwareRev.3 = entPhysicalFirmwareRev.4 = entPhysicalFirmwareRev.5 = entPhysicalFirmwareRev.6 = entPhysicalFirmwareRev.7 = entPhysicalFirmwareRev.8 = entPhysicalFirmwareRev.9 = entPhysicalFirmwareRev.10 = entPhysicalFirmwareRev.11 = entPhysicalFirmwareRev.12 = entPhysicalFirmwareRev.13 = entPhysicalFirmwareRev.14 = entPhysicalFirmwareRev.15 = entPhysicalFirmwareRev.16 = entPhysicalFirmwareRev.17 = entPhysicalFirmwareRev.18 = entPhysicalFirmwareRev.19 = entPhysicalFirmwareRev.20 = entPhysicalFirmwareRev.21 = entPhysicalFirmwareRev.22 = entPhysicalFirmwareRev.23 = entPhysicalFirmwareRev.24 = entPhysicalFirmwareRev.25 = entPhysicalFirmwareRev.26 = entPhysicalFirmwareRev.27 = entPhysicalFirmwareRev.28 = entPhysicalFirmwareRev.29 = entPhysicalFirmwareRev.30 = entPhysicalFirmwareRev.31 = entPhysicalFirmwareRev.32 = entPhysicalFirmwareRev.33 = entPhysicalFirmwareRev.34 = entPhysicalFirmwareRev.35 = entPhysicalFirmwareRev.36 = entPhysicalFirmwareRev.37 = entPhysicalFirmwareRev.38 = entPhysicalFirmwareRev.39 = entPhysicalFirmwareRev.40 = entPhysicalFirmwareRev.41 = entPhysicalFirmwareRev.42 = entPhysicalFirmwareRev.43 = entPhysicalFirmwareRev.44 = entPhysicalFirmwareRev.45 = entPhysicalSoftwareRev.1 = entPhysicalSoftwareRev.2 = 10.5.0.4 entPhysicalSoftwareRev.3 = entPhysicalSoftwareRev.4 = entPhysicalSoftwareRev.5 = entPhysicalSoftwareRev.6 = entPhysicalSoftwareRev.7 = entPhysicalSoftwareRev.8 = entPhysicalSoftwareRev.9 = entPhysicalSoftwareRev.10 = entPhysicalSoftwareRev.11 = entPhysicalSoftwareRev.12 = entPhysicalSoftwareRev.13 = entPhysicalSoftwareRev.14 = entPhysicalSoftwareRev.15 = entPhysicalSoftwareRev.16 = entPhysicalSoftwareRev.17 = entPhysicalSoftwareRev.18 = entPhysicalSoftwareRev.19 = entPhysicalSoftwareRev.20 = entPhysicalSoftwareRev.21 = entPhysicalSoftwareRev.22 = entPhysicalSoftwareRev.23 = entPhysicalSoftwareRev.24 = entPhysicalSoftwareRev.25 = entPhysicalSoftwareRev.26 = entPhysicalSoftwareRev.27 = entPhysicalSoftwareRev.28 = entPhysicalSoftwareRev.29 = entPhysicalSoftwareRev.30 = entPhysicalSoftwareRev.31 = entPhysicalSoftwareRev.32 = entPhysicalSoftwareRev.33 = entPhysicalSoftwareRev.34 = entPhysicalSoftwareRev.35 = entPhysicalSoftwareRev.36 = entPhysicalSoftwareRev.37 = entPhysicalSoftwareRev.38 = entPhysicalSoftwareRev.39 = entPhysicalSoftwareRev.40 = entPhysicalSoftwareRev.41 = entPhysicalSoftwareRev.42 = entPhysicalSoftwareRev.43 = entPhysicalSoftwareRev.44 = entPhysicalSoftwareRev.45 = entPhysicalSerialNum.1 = entPhysicalSerialNum.2 = CN0TRM6XCES009CA0012 entPhysicalSerialNum.3 = CN0TRM6XCES009CA0012 entPhysicalSerialNum.4 = entPhysicalSerialNum.5 = entPhysicalSerialNum.6 = entPhysicalSerialNum.7 = entPhysicalSerialNum.8 = entPhysicalSerialNum.9 = entPhysicalSerialNum.10 = entPhysicalSerialNum.11 = entPhysicalSerialNum.12 = entPhysicalSerialNum.13 = entPhysicalSerialNum.14 = entPhysicalSerialNum.15 = entPhysicalSerialNum.16 = entPhysicalSerialNum.17 = entPhysicalSerialNum.18 = entPhysicalSerialNum.19 = entPhysicalSerialNum.20 = entPhysicalSerialNum.21 = entPhysicalSerialNum.22 = entPhysicalSerialNum.23 = entPhysicalSerialNum.24 = entPhysicalSerialNum.25 = entPhysicalSerialNum.26 = entPhysicalSerialNum.27 = entPhysicalSerialNum.28 = entPhysicalSerialNum.29 = entPhysicalSerialNum.30 = entPhysicalSerialNum.31 = entPhysicalSerialNum.32 = entPhysicalSerialNum.33 = entPhysicalSerialNum.34 = entPhysicalSerialNum.35 = entPhysicalSerialNum.36 = entPhysicalSerialNum.37 = entPhysicalSerialNum.38 = entPhysicalSerialNum.39 = CN07R5RFCES009BU0268 entPhysicalSerialNum.40 = CN07R5RFCES009BU0269 entPhysicalSerialNum.41 = CN07R5RFCES009BU0420 entPhysicalSerialNum.42 = CN07R5RFCES009BU0395 entPhysicalSerialNum.43 = entPhysicalSerialNum.44 = CN0R17R1DED009AP0GFB entPhysicalSerialNum.45 = CN0R17R1DED009AP0GGW entPhysicalMfgName.1 = entPhysicalMfgName.2 = Dell EMC entPhysicalMfgName.3 = Dell EMC entPhysicalMfgName.4 = FS entPhysicalMfgName.5 = entPhysicalMfgName.6 = entPhysicalMfgName.7 = entPhysicalMfgName.8 = entPhysicalMfgName.9 = entPhysicalMfgName.10 = entPhysicalMfgName.11 = entPhysicalMfgName.12 = entPhysicalMfgName.13 = entPhysicalMfgName.14 = entPhysicalMfgName.15 = entPhysicalMfgName.16 = entPhysicalMfgName.17 = FS entPhysicalMfgName.18 = entPhysicalMfgName.19 = FS entPhysicalMfgName.20 = entPhysicalMfgName.21 = entPhysicalMfgName.22 = entPhysicalMfgName.23 = entPhysicalMfgName.24 = entPhysicalMfgName.25 = entPhysicalMfgName.26 = entPhysicalMfgName.27 = DELL entPhysicalMfgName.28 = DELL entPhysicalMfgName.29 = DELL entPhysicalMfgName.30 = DELL entPhysicalMfgName.31 = entPhysicalMfgName.32 = FS entPhysicalMfgName.33 = FS entPhysicalMfgName.34 = FS entPhysicalMfgName.35 = FS entPhysicalMfgName.36 = entPhysicalMfgName.37 = FS entPhysicalMfgName.38 = entPhysicalMfgName.39 = DEL entPhysicalMfgName.40 = DEL entPhysicalMfgName.41 = DEL entPhysicalMfgName.42 = DEL entPhysicalMfgName.43 = entPhysicalMfgName.44 = DEL entPhysicalMfgName.45 = DEL entPhysicalModelName.1 = entPhysicalModelName.2 = S5232F-ON entPhysicalModelName.3 = S5232F-ON entPhysicalModelName.4 = entPhysicalModelName.5 = entPhysicalModelName.6 = entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.14 = entPhysicalModelName.15 = entPhysicalModelName.16 = entPhysicalModelName.17 = entPhysicalModelName.18 = entPhysicalModelName.19 = entPhysicalModelName.20 = entPhysicalModelName.21 = entPhysicalModelName.22 = entPhysicalModelName.23 = entPhysicalModelName.24 = entPhysicalModelName.25 = entPhysicalModelName.26 = entPhysicalModelName.27 = entPhysicalModelName.28 = entPhysicalModelName.29 = entPhysicalModelName.30 = entPhysicalModelName.31 = entPhysicalModelName.32 = entPhysicalModelName.33 = entPhysicalModelName.34 = entPhysicalModelName.35 = entPhysicalModelName.36 = entPhysicalModelName.37 = entPhysicalModelName.38 = entPhysicalModelName.39 = entPhysicalModelName.40 = entPhysicalModelName.41 = entPhysicalModelName.42 = entPhysicalModelName.43 = entPhysicalModelName.44 = PWR SPLY,750W,AC,PS/IO,DELTA entPhysicalModelName.45 = PWR SPLY,750W,AC,PS/IO,DELTA entPhysicalAlias.1 = entPhysicalAlias.2 = entPhysicalAlias.3 = entPhysicalAlias.4 = entPhysicalAlias.5 = entPhysicalAlias.6 = entPhysicalAlias.7 = entPhysicalAlias.8 = entPhysicalAlias.9 = entPhysicalAlias.10 = entPhysicalAlias.11 = entPhysicalAlias.12 = entPhysicalAlias.13 = entPhysicalAlias.14 = entPhysicalAlias.15 = entPhysicalAlias.16 = entPhysicalAlias.17 = entPhysicalAlias.18 = entPhysicalAlias.19 = entPhysicalAlias.20 = entPhysicalAlias.21 = entPhysicalAlias.22 = entPhysicalAlias.23 = entPhysicalAlias.24 = entPhysicalAlias.25 = entPhysicalAlias.26 = entPhysicalAlias.27 = entPhysicalAlias.28 = entPhysicalAlias.29 = entPhysicalAlias.30 = entPhysicalAlias.31 = entPhysicalAlias.32 = entPhysicalAlias.33 = entPhysicalAlias.34 = entPhysicalAlias.35 = entPhysicalAlias.36 = entPhysicalAlias.37 = entPhysicalAlias.38 = entPhysicalAlias.39 = entPhysicalAlias.40 = entPhysicalAlias.41 = entPhysicalAlias.42 = entPhysicalAlias.43 = entPhysicalAlias.44 = entPhysicalAlias.45 = entPhysicalAssetID.1 = entPhysicalAssetID.2 = 5SKC9Z2 entPhysicalAssetID.3 = 5SKC9Z2 entPhysicalAssetID.4 = entPhysicalAssetID.5 = entPhysicalAssetID.6 = entPhysicalAssetID.7 = entPhysicalAssetID.8 = entPhysicalAssetID.9 = entPhysicalAssetID.10 = entPhysicalAssetID.11 = entPhysicalAssetID.12 = entPhysicalAssetID.13 = entPhysicalAssetID.14 = entPhysicalAssetID.15 = entPhysicalAssetID.16 = entPhysicalAssetID.17 = entPhysicalAssetID.18 = entPhysicalAssetID.19 = entPhysicalAssetID.20 = entPhysicalAssetID.21 = entPhysicalAssetID.22 = entPhysicalAssetID.23 = entPhysicalAssetID.24 = entPhysicalAssetID.25 = entPhysicalAssetID.26 = entPhysicalAssetID.27 = entPhysicalAssetID.28 = entPhysicalAssetID.29 = entPhysicalAssetID.30 = entPhysicalAssetID.31 = entPhysicalAssetID.32 = entPhysicalAssetID.33 = entPhysicalAssetID.34 = entPhysicalAssetID.35 = entPhysicalAssetID.36 = entPhysicalAssetID.37 = entPhysicalAssetID.38 = entPhysicalAssetID.39 = entPhysicalAssetID.40 = entPhysicalAssetID.41 = entPhysicalAssetID.42 = entPhysicalAssetID.43 = entPhysicalAssetID.44 = entPhysicalAssetID.45 = entPhysicalIsFRU.1 = false entPhysicalIsFRU.2 = true entPhysicalIsFRU.3 = false entPhysicalIsFRU.4 = false entPhysicalIsFRU.5 = false entPhysicalIsFRU.6 = false entPhysicalIsFRU.7 = false entPhysicalIsFRU.8 = false entPhysicalIsFRU.9 = false entPhysicalIsFRU.10 = false entPhysicalIsFRU.11 = false entPhysicalIsFRU.12 = false entPhysicalIsFRU.13 = false entPhysicalIsFRU.14 = false entPhysicalIsFRU.15 = false entPhysicalIsFRU.16 = false entPhysicalIsFRU.17 = false entPhysicalIsFRU.18 = false entPhysicalIsFRU.19 = false entPhysicalIsFRU.20 = false entPhysicalIsFRU.21 = false entPhysicalIsFRU.22 = false entPhysicalIsFRU.23 = false entPhysicalIsFRU.24 = false entPhysicalIsFRU.25 = false entPhysicalIsFRU.26 = false entPhysicalIsFRU.27 = false entPhysicalIsFRU.28 = false entPhysicalIsFRU.29 = false entPhysicalIsFRU.30 = false entPhysicalIsFRU.31 = false entPhysicalIsFRU.32 = false entPhysicalIsFRU.33 = false entPhysicalIsFRU.34 = false entPhysicalIsFRU.35 = false entPhysicalIsFRU.36 = false entPhysicalIsFRU.37 = false entPhysicalIsFRU.38 = false entPhysicalIsFRU.39 = true entPhysicalIsFRU.40 = true entPhysicalIsFRU.41 = true entPhysicalIsFRU.42 = true entPhysicalIsFRU.43 = false entPhysicalIsFRU.44 = true entPhysicalIsFRU.45 = true entPhysicalMfgDate.1 = entPhysicalMfgDate.2 = entPhysicalMfgDate.3 = entPhysicalMfgDate.4 = entPhysicalMfgDate.5 = entPhysicalMfgDate.6 = entPhysicalMfgDate.7 = entPhysicalMfgDate.8 = entPhysicalMfgDate.9 = entPhysicalMfgDate.10 = entPhysicalMfgDate.11 = entPhysicalMfgDate.12 = entPhysicalMfgDate.13 = entPhysicalMfgDate.14 = entPhysicalMfgDate.15 = entPhysicalMfgDate.16 = entPhysicalMfgDate.17 = entPhysicalMfgDate.18 = entPhysicalMfgDate.19 = entPhysicalMfgDate.20 = entPhysicalMfgDate.21 = entPhysicalMfgDate.22 = entPhysicalMfgDate.23 = entPhysicalMfgDate.24 = entPhysicalMfgDate.25 = entPhysicalMfgDate.26 = entPhysicalMfgDate.27 = entPhysicalMfgDate.28 = entPhysicalMfgDate.29 = entPhysicalMfgDate.30 = entPhysicalMfgDate.31 = entPhysicalMfgDate.32 = entPhysicalMfgDate.33 = entPhysicalMfgDate.34 = entPhysicalMfgDate.35 = entPhysicalMfgDate.36 = entPhysicalMfgDate.37 = entPhysicalMfgDate.38 = entPhysicalMfgDate.39 = entPhysicalMfgDate.40 = entPhysicalMfgDate.41 = entPhysicalMfgDate.42 = entPhysicalMfgDate.43 = entPhysicalMfgDate.44 = entPhysicalMfgDate.45 = entPhysicalUris.1 = "" entPhysicalUris.2 = "" entPhysicalUris.3 = "" entPhysicalUris.4 = "" entPhysicalUris.5 = "" entPhysicalUris.6 = "" entPhysicalUris.7 = "" entPhysicalUris.8 = "" entPhysicalUris.9 = "" entPhysicalUris.10 = "" entPhysicalUris.11 = "" entPhysicalUris.12 = "" entPhysicalUris.13 = "" entPhysicalUris.14 = "" entPhysicalUris.15 = "" entPhysicalUris.16 = "" entPhysicalUris.17 = "" entPhysicalUris.18 = "" entPhysicalUris.19 = "" entPhysicalUris.20 = "" entPhysicalUris.21 = "" entPhysicalUris.22 = "" entPhysicalUris.23 = "" entPhysicalUris.24 = "" entPhysicalUris.25 = "" entPhysicalUris.26 = "" entPhysicalUris.27 = "" entPhysicalUris.28 = "" entPhysicalUris.29 = "" entPhysicalUris.30 = "" entPhysicalUris.31 = "" entPhysicalUris.32 = "" entPhysicalUris.33 = "" entPhysicalUris.34 = "" entPhysicalUris.35 = "" entPhysicalUris.36 = "" entPhysicalUris.37 = "" entPhysicalUris.38 = "" entPhysicalUris.39 = "" entPhysicalUris.40 = "" entPhysicalUris.41 = "" entPhysicalUris.42 = "" entPhysicalUris.43 = "" entPhysicalUris.44 = "" entPhysicalUris.45 = "" entPhysicalUUID.1 = entPhysicalUUID.2 = entPhysicalUUID.3 = entPhysicalUUID.4 = entPhysicalUUID.5 = entPhysicalUUID.6 = entPhysicalUUID.7 = entPhysicalUUID.8 = entPhysicalUUID.9 = entPhysicalUUID.10 = entPhysicalUUID.11 = entPhysicalUUID.12 = entPhysicalUUID.13 = entPhysicalUUID.14 = entPhysicalUUID.15 = entPhysicalUUID.16 = entPhysicalUUID.17 = entPhysicalUUID.18 = entPhysicalUUID.19 = entPhysicalUUID.20 = entPhysicalUUID.21 = entPhysicalUUID.22 = entPhysicalUUID.23 = entPhysicalUUID.24 = entPhysicalUUID.25 = entPhysicalUUID.26 = entPhysicalUUID.27 = entPhysicalUUID.28 = entPhysicalUUID.29 = entPhysicalUUID.30 = entPhysicalUUID.31 = entPhysicalUUID.32 = entPhysicalUUID.33 = entPhysicalUUID.34 = entPhysicalUUID.35 = entPhysicalUUID.36 = entPhysicalUUID.37 = entPhysicalUUID.38 = entPhysicalUUID.39 = entPhysicalUUID.40 = entPhysicalUUID.41 = entPhysicalUUID.42 = entPhysicalUUID.43 = entPhysicalUUID.44 = entPhysicalUUID.45 = ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' entAliasMappingIdentifier[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.042s[0m][0m STDOUT[ entAliasMappingIdentifier = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '1' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00043893s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '2' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00027609s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '3' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024486s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '4' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024295s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '5' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00028586s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '6' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024080s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '7' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024009s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '8' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024009s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '9' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023890s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '10' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00026417s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '11' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023890s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '12' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023818s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '13' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00026107s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '14' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023890s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '15' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023699s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '16' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00029206s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '17' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025606s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '18' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00026178s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '19' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024796s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '20' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024605s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '21' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025702s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '22' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024390s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '23' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025487s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '24' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024295s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '25' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024295s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '26' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025487s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '27' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024104s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '28' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024295s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '29' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025511s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '30' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023818s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '31' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025702s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '32' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023699s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '33' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023699s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '34' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00026011s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '35' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023603s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '36' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023508s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '37' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025797s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '38' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023603s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '39' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00023603s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '40' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025797s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '41' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024414s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '42' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00025392s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '43' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024080s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '44' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00024199s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `entPhysicalIndex` = '45' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00026202s[0m][0m SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '84' AND `inventory_mib` = 'ENTITY-MIB'[0m][0m SQL RUNTIME[[0;32m0.00030804s[0m][0m [1;44;96m > $valid[$module][0m[44;36m /opt/observium/includes/discovery/inventory.inc.php:22 [0m array( [ENTITY-MIB] => array( [1] => int(1) [2] => int(1) [3] => int(1) [4] => int(1) [5] => int(1) [6] => int(1) [7] => int(1) [8] => int(1) [9] => int(1) [10] => int(1) [11] => int(1) [12] => int(1) [13] => int(1) [14] => int(1) [15] => int(1) [16] => int(1) [17] => int(1) [18] => int(1) [19] => int(1) [20] => int(1) [21] => int(1) [22] => int(1) [23] => int(1) [24] => int(1) [25] => int(1) [26] => int(1) [27] => int(1) [28] => int(1) [29] => int(1) [30] => int(1) [31] => int(1) [32] => int(1) [33] => int(1) [34] => int(1) [35] => int(1) [36] => int(1) [37] => int(1) [38] => int(1) [39] => int(1) [40] => int(1) [41] => int(1) [42] => int(1) [43] => int(1) [44] => int(1) [45] => int(1) ) ) [0;36m o [1;37mChanges [0m 45 unchanged [0;36m o [1;37mDuration [0m 0.2819s [0;36m##### [1;37mModule Start: [1;31mprintersupplies[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `printersupplies` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014281s[0m][0m [0;36m o [1;37mDuration [0m 0.0007s [0;36m##### [1;37mModule Start: [1;31msensors[0;36m #####[0m [0m [0;36m o [1;37mDELLEMC-OS10-CHASSIS-MIB[0m os10ChassisTemp [ CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELLEMC-OS10-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' os10ChassisTemp[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0181s[0m][0m STDOUT[ os10ChassisTemp.1 = 52 ] SNMP STATUS[[0;32mTRUE[0m][0m Store in cache Table OID: DELLEMC-OS10-CHASSIS-MIB::os10ChassisTemp Discover sensor: [class: temperature, device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11.1, index: 1, type: DELLEMC-OS10-CHASSIS-MIB-os10ChassisTemp, descr: Chassis, scale: 1, limits: (, , , ), CURRENT: 52, , SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '84' AND `sensor_type` = 'DELLEMC-OS10-CHASSIS-MIB-os10ChassisTemp' AND `sensor_index` = '1')[0m][0m SQL RUNTIME[[0;32m0.00026512s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '84' AND `sensor_type` = 'DELLEMC-OS10-CHASSIS-MIB-os10ChassisTemp' AND `sensor_index` = '1'[0m][0m SQL RUNTIME[[0;32m0.00023603s[0m][0m SQL[[0;33mSELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '1218' AND `attrib_type` = 'sensor_addition'[0m][0m SQL RUNTIME[[0;32m0.00016904s[0m][0m .] [0;36m o [1;37mDELLEMC-OS10-CHASSIS-MIB[0m os10PowerSupplyOperStatus [ CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELLEMC-OS10-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' os10PowerSupplyTable[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0208s[0m][0m STDOUT[ os10PowerSupplyDevice.1 = chassis os10PowerSupplyDevice.2 = chassis os10PowerSupplyDeviceIndex.1 = 1 os10PowerSupplyDeviceIndex.2 = 1 os10PowerSupplyOperStatus.1 = up os10PowerSupplyOperStatus.2 = up os10PowerSupplyType.1 = ac os10PowerSupplyType.2 = ac os10PowerSupplyPPID.1 = "CN0R17R1DED009AP0GFB" os10PowerSupplyPPID.2 = "CN0R17R1DED009AP0GGW" os10PowerSupplyServiceTag.1 = "" os10PowerSupplyServiceTag.2 = "" os10PowerSupplyExpServiceCode.1 = "" os10PowerSupplyExpServiceCode.2 = "" ] SNMP STATUS[[0;32mTRUE[0m][0m Store in cache Table OID: DELLEMC-OS10-CHASSIS-MIB::os10PowerSupplyTable String 'Power Supply 1 (ac)' transformed by action [replace] to: 'Power Supply 1 (AC)' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4.1, index: 1, type: Os10CmnOperStatus, descr: Power Supply 1 (AC), CURRENT: 1, , ] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10PowerSupplyOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '1' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00039506s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10PowerSupplyOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '1' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00035405s[0m][0m . String 'Power Supply 2 (ac)' transformed by action [replace] to: 'Power Supply 2 (AC)' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4.2, index: 2, type: Os10CmnOperStatus, descr: Power Supply 2 (AC), CURRENT: 1, , ] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10PowerSupplyOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '2' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00024700s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10PowerSupplyOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '2' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00032902s[0m][0m .] os10FanOperStatus [ CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m DELLEMC-OS10-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' os10FanTable[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0665s[0m][0m STDOUT[ os10FanDevice.1 = chassis os10FanDevice.2 = chassis os10FanDevice.3 = chassis os10FanDevice.4 = chassis os10FanDevice.5 = chassis os10FanDevice.6 = chassis os10FanDevice.7 = chassis os10FanDevice.8 = chassis os10FanDevice.9 = chassis os10FanDevice.10 = chassis os10FanDeviceIndex.1 = 1 os10FanDeviceIndex.2 = 1 os10FanDeviceIndex.3 = 1 os10FanDeviceIndex.4 = 1 os10FanDeviceIndex.5 = 1 os10FanDeviceIndex.6 = 1 os10FanDeviceIndex.7 = 1 os10FanDeviceIndex.8 = 1 os10FanDeviceIndex.9 = 1 os10FanDeviceIndex.10 = 1 os10FanEntity.1 = psu os10FanEntity.2 = psu os10FanEntity.3 = fanTray os10FanEntity.4 = fanTray os10FanEntity.5 = fanTray os10FanEntity.6 = fanTray os10FanEntity.7 = fanTray os10FanEntity.8 = fanTray os10FanEntity.9 = fanTray os10FanEntity.10 = fanTray os10FanEntitySlot.1 = 1 os10FanEntitySlot.2 = 2 os10FanEntitySlot.3 = 1 os10FanEntitySlot.4 = 1 os10FanEntitySlot.5 = 2 os10FanEntitySlot.6 = 2 os10FanEntitySlot.7 = 3 os10FanEntitySlot.8 = 3 os10FanEntitySlot.9 = 4 os10FanEntitySlot.10 = 4 os10FanId.1 = 1 os10FanId.2 = 1 os10FanId.3 = 1 os10FanId.4 = 2 os10FanId.5 = 1 os10FanId.6 = 2 os10FanId.7 = 1 os10FanId.8 = 2 os10FanId.9 = 1 os10FanId.10 = 2 os10FanOperStatus.1 = up os10FanOperStatus.2 = up os10FanOperStatus.3 = up os10FanOperStatus.4 = up os10FanOperStatus.5 = up os10FanOperStatus.6 = up os10FanOperStatus.7 = up os10FanOperStatus.8 = up os10FanOperStatus.9 = up os10FanOperStatus.10 = up ] SNMP STATUS[[0;32mTRUE[0m][0m Store in cache Table OID: DELLEMC-OS10-CHASSIS-MIB::os10FanTable String 'Fan psu 1' transformed by action [replace] to: 'Fan Power Supply 1' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.1, index: 1, type: Os10CmnOperStatus, descr: Fan Power Supply 1, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '1' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00038314s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '1' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00035405s[0m][0m . String 'Fan psu 2' transformed by action [replace] to: 'Fan Power Supply 2' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.2, index: 2, type: Os10CmnOperStatus, descr: Fan Power Supply 2, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '2' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00025702s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '2' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00033808s[0m][0m . String 'Fan fanTray 1' transformed by action [replace] to: 'Fan Tray 1' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.3, index: 3, type: Os10CmnOperStatus, descr: Fan Tray 1, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '3' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00026011s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '3' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00030899s[0m][0m . String 'Fan fanTray 1' transformed by action [replace] to: 'Fan Tray 1' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.4, index: 4, type: Os10CmnOperStatus, descr: Fan Tray 1, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '4' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00029707s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '4' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00031710s[0m][0m . String 'Fan fanTray 2' transformed by action [replace] to: 'Fan Tray 2' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.5, index: 5, type: Os10CmnOperStatus, descr: Fan Tray 2, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '5' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00027609s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '5' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00030804s[0m][0m . String 'Fan fanTray 2' transformed by action [replace] to: 'Fan Tray 2' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.6, index: 6, type: Os10CmnOperStatus, descr: Fan Tray 2, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '6' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00028205s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '6' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00030184s[0m][0m . String 'Fan fanTray 3' transformed by action [replace] to: 'Fan Tray 3' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.7, index: 7, type: Os10CmnOperStatus, descr: Fan Tray 3, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '7' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00026512s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '7' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00030494s[0m][0m . String 'Fan fanTray 3' transformed by action [replace] to: 'Fan Tray 3' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.8, index: 8, type: Os10CmnOperStatus, descr: Fan Tray 3, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '8' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00026393s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '8' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00031590s[0m][0m . String 'Fan fanTray 4' transformed by action [replace] to: 'Fan Tray 4' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.9, index: 9, type: Os10CmnOperStatus, descr: Fan Tray 4, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '9' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00026917s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '9' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00031900s[0m][0m . String 'Fan fanTray 4' transformed by action [replace] to: 'Fan Tray 4' Discover status: [device: ssw006, oid: .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7.10, index: 10, type: Os10CmnOperStatus, descr: Fan Tray 4, CURRENT: 1, , fan] SQL[[0;33mSELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '10' AND `poller_type`= 'snmp')[0m][0m SQL RUNTIME[[0;32m0.00026894s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `status_mib` = 'DELLEMC-OS10-CHASSIS-MIB' AND `status_object` = 'os10FanOperStatus' AND `status_type` = 'Os10CmnOperStatus' AND `status_index` = '10' AND `poller_type`= 'snmp'[0m][0m SQL RUNTIME[[0;32m0.00030208s[0m][0m .] [0;36m o [1;37mDELL-NETWORKING-CHASSIS-MIB [0m DELL-NETWORKING-CHASSIS-MIB CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetStackUnitTemp[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0182s[0m][0m STDOUT[ dellNetStackUnitTemp = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetStackUnitStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0179s[0m][0m STDOUT[ dellNetStackUnitStatus = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetFanTrayOperStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0177s[0m][0m STDOUT[ dellNetFanTrayOperStatus = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetPowerSupplyOperStatus[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0177s[0m][0m STDOUT[ dellNetPowerSupplyOperStatus = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetPowerSupplyUsage[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0174s[0m][0m STDOUT[ dellNetPowerSupplyUsage = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DELL-NETWORKING-CHASSIS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'ssw006':'161' dellNetSysIfXfpRecvTemp[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0177s[0m][0m STDOUT[ dellNetSysIfXfpRecvTemp = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m [0;36m o [1;37mENTITY-SENSOR-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' entPhySensorValue[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0452s[0m][0m STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00041485s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00020099s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00019193s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00019097s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018597s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018716s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00020695s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018501s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018215s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018215s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018191s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018287s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018096s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00019693s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018001s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00020289s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018001s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018692s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017905s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017905s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00019717s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017786s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00018001s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017905s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00020695s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017905s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017810s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00017810s[0m][0m SQL[[0;33mSELECT * FROM `sensors` WHERE `device_id` = '84' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00022697s[0m][0m SQL[[0;33mSELECT * FROM `status` WHERE `device_id` = '84' AND `poller_type` = 'snmp' AND `status_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00023508s[0m][0m SQL[[0;33mSELECT * FROM `counters` WHERE `device_id` = '84' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00020218s[0m][0m [0;36m o [1;37mDuration [0m 0.293s [0;36m##### [1;37mModule Start: [1;31mstorage[0;36m #####[0m [0m [0;36m o [1;37mUCD-SNMP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' dskEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0177s[0m][0m STDOUT[ dskIndex.1 = 1 dskIndex.2 = 2 dskIndex.3 = 3 dskIndex.4 = 4 dskIndex.5 = 5 dskIndex.6 = 6 dskIndex.7 = 7 dskIndex.8 = 8 dskIndex.9 = 9 dskIndex.10 = 10 dskIndex.11 = 11 dskIndex.12 = 12 dskPath.1 = / dskPath.2 = /var dskPath.3 = / dskPath.4 = /run dskPath.5 = /dev/shm dskPath.6 = /run/lock dskPath.7 = /sys/fs/cgroup dskPath.8 = /mnt/boot dskPath.9 = /mnt/onie-boot dskPath.10 = /mnt/license dskPath.11 = /config dskPath.12 = /alt dskDevice.1 = /dev/mapper/OS10-SYSROOT2 dskDevice.2 = dskDevice.3 = /dev/mapper/OS10-SYSROOT2 dskDevice.4 = tmpfs dskDevice.5 = tmpfs dskDevice.6 = tmpfs dskDevice.7 = tmpfs dskDevice.8 = /dev/sda3 dskDevice.9 = /dev/sda2 dskDevice.10 = /dev/mapper/OS10-LICENSE dskDevice.11 = /dev/mapper/OS10-CONFIG dskDevice.12 = /dev/mapper/OS10-SYSROOT1 dskMinimum.1 = -1 dskMinimum.2 = -1 dskMinimum.3 = -1 dskMinimum.4 = -1 dskMinimum.5 = -1 dskMinimum.6 = -1 dskMinimum.7 = -1 dskMinimum.8 = -1 dskMinimum.9 = -1 dskMinimum.10 = -1 dskMinimum.11 = -1 dskMinimum.12 = -1 dskMinPercent.1 = 10 dskMinPercent.2 = 5 dskMinPercent.3 = 10 dskMinPercent.4 = 10 dskMinPercent.5 = 10 dskMinPercent.6 = 10 dskMinPercent.7 = 10 dskMinPercent.8 = 10 dskMinPercent.9 = 10 dskMinPercent.10 = 10 dskMinPercent.11 = 10 dskMinPercent.12 = 10 dskTotal.1 = 30171084 dskTotal.2 = 0 dskTotal.3 = 30171084 dskTotal.4 = 1637556 dskTotal.5 = 8187776 dskTotal.6 = 5120 dskTotal.7 = 8187776 dskTotal.8 = 6907 dskTotal.9 = 122835 dskTotal.10 = 27633 dskTotal.11 = 487652 dskTotal.12 = 30171172 dskAvail.1 = 26749180 dskAvail.2 = 0 dskAvail.3 = 26749180 dskAvail.4 = 1632360 dskAvail.5 = 8187752 dskAvail.6 = 5120 dskAvail.7 = 8187776 dskAvail.8 = 3433 dskAvail.9 = 90946 dskAvail.10 = 24941 dskAvail.11 = 454269 dskAvail.12 = 26177152 dskUsed.1 = 1866244 dskUsed.2 = 0 dskUsed.3 = 1866244 dskUsed.4 = 5196 dskUsed.5 = 24 dskUsed.6 = 0 dskUsed.7 = 0 dskUsed.8 = 2902 dskUsed.9 = 22715 dskUsed.10 = 399 dskUsed.11 = 3687 dskUsed.12 = 2438360 dskPercent.1 = 6 dskPercent.2 = 0 dskPercent.3 = 6 dskPercent.4 = 0 dskPercent.5 = 0 dskPercent.6 = 0 dskPercent.7 = 0 dskPercent.8 = 42 dskPercent.9 = 18 dskPercent.10 = 1 dskPercent.11 = 1 dskPercent.12 = 8 dskPercentNode.1 = 2 dskPercentNode.2 = 0 dskPercentNode.3 = 2 dskPercentNode.4 = 0 dskPercentNode.5 = 0 dskPercentNode.6 = 0 dskPercentNode.7 = 0 dskPercentNode.8 = 14 dskPercentNode.9 = 1 dskPercentNode.10 = 0 dskPercentNode.11 = 0 dskPercentNode.12 = 2 dskTotalLow.1 = 30171084 dskTotalLow.2 = 0 dskTotalLow.3 = 30171084 dskTotalLow.4 = 1637556 dskTotalLow.5 = 8187776 dskTotalLow.6 = 5120 dskTotalLow.7 = 8187776 dskTotalLow.8 = 6907 dskTotalLow.9 = 122835 dskTotalLow.10 = 27633 dskTotalLow.11 = 487652 dskTotalLow.12 = 30171172 dskTotalHigh.1 = 0 dskTotalHigh.2 = 0 dskTotalHigh.3 = 0 dskTotalHigh.4 = 0 dskTotalHigh.5 = 0 dskTotalHigh.6 = 0 dskTotalHigh.7 = 0 dskTotalHigh.8 = 0 dskTotalHigh.9 = 0 dskTotalHigh.10 = 0 dskTotalHigh.11 = 0 dskTotalHigh.12 = 0 dskAvailLow.1 = 26749180 dskAvailLow.2 = 0 dskAvailLow.3 = 26749180 dskAvailLow.4 = 1632360 dskAvailLow.5 = 8187752 dskAvailLow.6 = 5120 dskAvailLow.7 = 8187776 dskAvailLow.8 = 3433 dskAvailLow.9 = 90946 dskAvailLow.10 = 24941 dskAvailLow.11 = 454269 dskAvailLow.12 = 26177152 dskAvailHigh.1 = 0 dskAvailHigh.2 = 0 dskAvailHigh.3 = 0 dskAvailHigh.4 = 0 dskAvailHigh.5 = 0 dskAvailHigh.6 = 0 dskAvailHigh.7 = 0 dskAvailHigh.8 = 0 dskAvailHigh.9 = 0 dskAvailHigh.10 = 0 dskAvailHigh.11 = 0 dskAvailHigh.12 = 0 dskUsedLow.1 = 1866244 dskUsedLow.2 = 0 dskUsedLow.3 = 1866244 dskUsedLow.4 = 5196 dskUsedLow.5 = 24 dskUsedLow.6 = 0 dskUsedLow.7 = 0 dskUsedLow.8 = 2902 dskUsedLow.9 = 22715 dskUsedLow.10 = 399 dskUsedLow.11 = 3687 dskUsedLow.12 = 2438360 dskUsedHigh.1 = 0 dskUsedHigh.2 = 0 dskUsedHigh.3 = 0 dskUsedHigh.4 = 0 dskUsedHigh.5 = 0 dskUsedHigh.6 = 0 dskUsedHigh.7 = 0 dskUsedHigh.8 = 0 dskUsedHigh.9 = 0 dskUsedHigh.10 = 0 dskUsedHigh.11 = 0 dskUsedHigh.12 = 0 dskErrorFlag.1 = noError dskErrorFlag.2 = error dskErrorFlag.3 = noError dskErrorFlag.4 = noError dskErrorFlag.5 = noError dskErrorFlag.6 = noError dskErrorFlag.7 = noError dskErrorFlag.8 = noError dskErrorFlag.9 = noError dskErrorFlag.10 = noError dskErrorFlag.11 = noError dskErrorFlag.12 = noError dskErrorMsg.1 = dskErrorMsg.2 = /var: less than 5% free (= 0%) dskErrorMsg.3 = dskErrorMsg.4 = dskErrorMsg.5 = dskErrorMsg.6 = dskErrorMsg.7 = dskErrorMsg.8 = dskErrorMsg.9 = dskErrorMsg.10 = dskErrorMsg.11 = dskErrorMsg.12 = ] SNMP STATUS[[0;32mTRUE[0m][0m [0;36m o [1;37mHOST-RESOURCES-MIB [0m 84 -> 31, hrStorageFixedDisk, HOST-RESOURCES-MIB, /, 4096, 30895190016, 1911033856, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '31' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00021696s[0m][0m 84 -> 37, hrStorageFixedDisk, HOST-RESOURCES-MIB, /run, 4096, 1676857344, 5320704, 0 Skipped by equals: /run, /run 84 -> 39, hrStorageFixedDisk, HOST-RESOURCES-MIB, /dev/shm, 4096, 8384282624, 24576, 0 Skipped by equals: /dev/shm, /dev/shm 84 -> 40, hrStorageFixedDisk, HOST-RESOURCES-MIB, /run/lock, 4096, 5242880, 0, 0 Skipped by regexp: /^\/run\//, /run/lock 84 -> 41, hrStorageFixedDisk, HOST-RESOURCES-MIB, /sys/fs/cgroup, 4096, 8384282624, 0, 0 Skipped by regexp: /^\/sys\//, /sys/fs/cgroup 84 -> 59, hrStorageFixedDisk, HOST-RESOURCES-MIB, /mnt/boot, 1024, 7072768, 2971648, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '59' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00015402s[0m][0m 84 -> 60, hrStorageFixedDisk, HOST-RESOURCES-MIB, /mnt/onie-boot, 1024, 125783040, 23260160, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '60' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00014997s[0m][0m 84 -> 61, hrStorageFixedDisk, HOST-RESOURCES-MIB, /mnt/license, 1024, 28296192, 408576, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '61' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00015211s[0m][0m 84 -> 62, hrStorageFixedDisk, HOST-RESOURCES-MIB, /config, 1024, 499355648, 3775488, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '62' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00014806s[0m][0m 84 -> 64, hrStorageFixedDisk, HOST-RESOURCES-MIB, /alt, 4096, 30895280128, 2496880640, 0 SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84' AND `storage_index` = '64' AND `storage_mib` = 'HOST-RESOURCES-MIB'[0m][0m SQL RUNTIME[[0;32m0.00014615s[0m][0m 84 -> 2, , UCD-SNMP-MIB, /var, 1024, 0, 0, 1 [1;44;96m > $valid['storage'][0m[44;36m /opt/observium/includes/discovery/storage.inc.php:160 [0m array( [HOST-RESOURCES-MIB] => array( [31] => string(1) "/" [59] => string(9) "/mnt/boot" [60] => string(14) "/mnt/onie-boot" [61] => string(12) "/mnt/license" [62] => string(7) "/config" [64] => string(4) "/alt" ) ) SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00018287s[0m][0m 31 -> HOST-RESOURCES-MIB 59 -> HOST-RESOURCES-MIB 60 -> HOST-RESOURCES-MIB 61 -> HOST-RESOURCES-MIB 62 -> HOST-RESOURCES-MIB 64 -> HOST-RESOURCES-MIB [1;44;96m > $valid[$module][0m[44;36m /opt/observium/includes/discovery/storage.inc.php:181 [0m array( [HOST-RESOURCES-MIB] => array( [31] => string(1) "/" [59] => string(9) "/mnt/boot" [60] => string(14) "/mnt/onie-boot" [61] => string(12) "/mnt/license" [62] => string(7) "/config" [64] => string(4) "/alt" ) ) [0;36m o [1;37mChanges [0m 6 unchanged [0;36m o [1;37mDuration [0m 0.0235s [0;36m##### [1;37mModule Start: [1;31mneighbours[0;36m #####[0m [0m [0;36m o [1;37mLLDP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemChassisIdSubtype[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2282s[0m][0m STDOUT[ lldpRemChassisIdSubtype.2400.8.1 = macAddress lldpRemChassisIdSubtype.3000.1400.2 = macAddress lldpRemChassisIdSubtype.3000.1408.3 = macAddress lldpRemChassisIdSubtype.3000.1416.4 = macAddress lldpRemChassisIdSubtype.3000.1424.5 = macAddress lldpRemChassisIdSubtype.3400.1280.7 = macAddress lldpRemChassisIdSubtype.3400.1296.6 = macAddress ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemChassisId[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2282s[0m][0m STDOUT[ lldpRemChassisId.2400.8.1 = "8C 04 BA EC 10 C0 " lldpRemChassisId.3000.1400.2 = "8C 04 BA D3 9A C0 " lldpRemChassisId.3000.1408.3 = "8C 04 BA D3 9A C0 " lldpRemChassisId.3000.1416.4 = "8C 04 BA D3 9A C0 " lldpRemChassisId.3000.1424.5 = "8C 04 BA D3 9A C0 " lldpRemChassisId.3400.1280.7 = "98 03 9B 97 7E B7 " lldpRemChassisId.3400.1296.6 = "0C 42 A1 04 4A 8B " ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemPortIdSubtype[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2274s[0m][0m STDOUT[ lldpRemPortIdSubtype.2400.8.1 = interfaceName lldpRemPortIdSubtype.3000.1400.2 = interfaceName lldpRemPortIdSubtype.3000.1408.3 = interfaceName lldpRemPortIdSubtype.3000.1416.4 = interfaceName lldpRemPortIdSubtype.3000.1424.5 = interfaceName lldpRemPortIdSubtype.3400.1280.7 = macAddress lldpRemPortIdSubtype.3400.1296.6 = macAddress ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemPortId[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2302s[0m][0m STDOUT[ lldpRemPortId.2400.8.1 = "ethernet1/1/17" lldpRemPortId.3000.1400.2 = "ethernet1/1/29" lldpRemPortId.3000.1408.3 = "ethernet1/1/30" lldpRemPortId.3000.1416.4 = "ethernet1/1/31" lldpRemPortId.3000.1424.5 = "ethernet1/1/32" lldpRemPortId.3400.1280.7 = "98 03 9B 97 7E B7 " lldpRemPortId.3400.1296.6 = "0C 42 A1 04 4A 8B " ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemPortDesc[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2277s[0m][0m STDOUT[ lldpRemPortDesc.2400.8.1 = ethernet1/1/17 lldpRemPortDesc.3000.1400.2 = ethernet1/1/29 lldpRemPortDesc.3000.1408.3 = ethernet1/1/30 lldpRemPortDesc.3000.1416.4 = ethernet1/1/31 lldpRemPortDesc.3000.1424.5 = ethernet1/1/32 lldpRemPortDesc.3400.1280.7 = Interface 7 as ens3f1 lldpRemPortDesc.3400.1296.6 = Interface 7 as ens3f1 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemSysName[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.229s[0m][0m STDOUT[ lldpRemSysName.2400.8.1 = ssw009 lldpRemSysName.3000.1400.2 = ssw007 lldpRemSysName.3000.1408.3 = ssw007 lldpRemSysName.3000.1416.4 = ssw007 lldpRemSysName.3000.1424.5 = ssw007 lldpRemSysName.3400.1280.7 = dps021.plants.ox.ac.uk lldpRemSysName.3400.1296.6 = dps019.plants.ox.ac.uk ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemSysDesc[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2285s[0m][0m STDOUT[ lldpRemSysDesc.2400.8.1 = Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S3048-ON lldpRemSysDesc.3000.1400.2 = Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON lldpRemSysDesc.3000.1408.3 = Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON lldpRemSysDesc.3000.1416.4 = Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON lldpRemSysDesc.3000.1424.5 = Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON lldpRemSysDesc.3400.1280.7 = Linux dps021.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64 lldpRemSysDesc.3400.1296.6 = Linux dps019.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemManAddrIfId[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.2382s[0m][0m STDOUT[ lldpRemManAddrIfId.2400.8.1.6.31.140.4.186.236.16.192.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0 = 0 lldpRemManAddrIfId.3000.1400.2.1.4.192.168.100.114 = 9 lldpRemManAddrIfId.3000.1400.2.2.16.254.128.0.0.0.0.0.0.142.4.186.255.254.211.154.192 = 9 lldpRemManAddrIfId.3000.1408.3.1.4.192.168.100.114 = 9 lldpRemManAddrIfId.3000.1408.3.2.16.254.128.0.0.0.0.0.0.142.4.186.255.254.211.154.192 = 9 lldpRemManAddrIfId.3000.1416.4.1.4.192.168.100.114 = 9 lldpRemManAddrIfId.3000.1416.4.2.16.254.128.0.0.0.0.0.0.142.4.186.255.254.211.154.192 = 9 lldpRemManAddrIfId.3000.1424.5.1.4.192.168.100.114 = 9 lldpRemManAddrIfId.3000.1424.5.2.16.254.128.0.0.0.0.0.0.142.4.186.255.254.211.154.192 = 9 lldpRemManAddrIfId.3400.1280.7.2.16.254.128.0.0.0.0.0.0.220.175.241.132.149.249.92.193 = 7 lldpRemManAddrIfId.3400.1296.6.2.16.254.128.0.0.0.0.0.0.163.129.3.46.181.33.107.215 = 7 ] SNMP STATUS[[0;32mTRUE[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUsb -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpRemManAddr[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0274s[0m][0m STDOUT[ lldpRemManAddr = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m [1;44;96m [0m[44;36m /opt/observium/includes/discovery/neighbours/lldp-mib.inc.php:129 [0m array( [2400.8.1] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "8C 04 BA EC 10 C0 " [lldpRemPortIdSubtype] => string(13) "interfaceName" [lldpRemPortId] => string(14) "ethernet1/1/17" [lldpRemPortDesc] => string(14) "ethernet1/1/17" [lldpRemSysName] => string(6) "ssw009" [lldpRemSysDesc] => string(175) "Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S3048-ON" [lldpRemManAddrIfId] => string(1) "0" [lldpRemMan] => array( [140.4.186.236.16.192.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0] => array( [lldpRemManAddrIfId] => string(1) "0" ) ) ) [3000.1400.2] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "8C 04 BA D3 9A C0 " [lldpRemPortIdSubtype] => string(13) "interfaceName" [lldpRemPortId] => string(14) "ethernet1/1/29" [lldpRemPortDesc] => string(14) "ethernet1/1/29" [lldpRemSysName] => string(6) "ssw007" [lldpRemSysDesc] => string(176) "Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON" [lldpRemManAddrIfId] => string(1) "9" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:8e04:baff:fed3:9ac0" [lldpRemMan] => array( [192.168.100.114] => array( [lldpRemManAddrIfId] => string(1) "9" ) [fe80:0000:0000:0000:8e04:baff:fed3:9ac0] => array( [lldpRemManAddrIfId] => string(1) "9" ) ) ) [3000.1408.3] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "8C 04 BA D3 9A C0 " [lldpRemPortIdSubtype] => string(13) "interfaceName" [lldpRemPortId] => string(14) "ethernet1/1/30" [lldpRemPortDesc] => string(14) "ethernet1/1/30" [lldpRemSysName] => string(6) "ssw007" [lldpRemSysDesc] => string(176) "Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON" [lldpRemManAddrIfId] => string(1) "9" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:8e04:baff:fed3:9ac0" [lldpRemMan] => array( [192.168.100.114] => array( [lldpRemManAddrIfId] => string(1) "9" ) [fe80:0000:0000:0000:8e04:baff:fed3:9ac0] => array( [lldpRemManAddrIfId] => string(1) "9" ) ) ) [3000.1416.4] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "8C 04 BA D3 9A C0 " [lldpRemPortIdSubtype] => string(13) "interfaceName" [lldpRemPortId] => string(14) "ethernet1/1/31" [lldpRemPortDesc] => string(14) "ethernet1/1/31" [lldpRemSysName] => string(6) "ssw007" [lldpRemSysDesc] => string(176) "Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON" [lldpRemManAddrIfId] => string(1) "9" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:8e04:baff:fed3:9ac0" [lldpRemMan] => array( [192.168.100.114] => array( [lldpRemManAddrIfId] => string(1) "9" ) [fe80:0000:0000:0000:8e04:baff:fed3:9ac0] => array( [lldpRemManAddrIfId] => string(1) "9" ) ) ) [3000.1424.5] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "8C 04 BA D3 9A C0 " [lldpRemPortIdSubtype] => string(13) "interfaceName" [lldpRemPortId] => string(14) "ethernet1/1/32" [lldpRemPortDesc] => string(14) "ethernet1/1/32" [lldpRemSysName] => string(6) "ssw007" [lldpRemSysDesc] => string(176) "Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON" [lldpRemManAddrIfId] => string(1) "9" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:8e04:baff:fed3:9ac0" [lldpRemMan] => array( [192.168.100.114] => array( [lldpRemManAddrIfId] => string(1) "9" ) [fe80:0000:0000:0000:8e04:baff:fed3:9ac0] => array( [lldpRemManAddrIfId] => string(1) "9" ) ) ) [3400.1280.7] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "98 03 9B 97 7E B7 " [lldpRemPortIdSubtype] => string(10) "macAddress" [lldpRemPortId] => string(18) "98 03 9B 97 7E B7 " [lldpRemPortDesc] => string(23) "Interface 7 as ens3f1" [lldpRemSysName] => string(22) "dps021.plants.ox.ac.uk" [lldpRemSysDesc] => string(99) "Linux dps021.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64" [lldpRemManAddrIfId] => string(1) "7" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:dcaf:f184:95f9:5cc1" [lldpRemMan] => array( [fe80:0000:0000:0000:dcaf:f184:95f9:5cc1] => array( [lldpRemManAddrIfId] => string(1) "7" ) ) ) [3400.1296.6] => array( [lldpRemChassisIdSubtype] => string(10) "macAddress" [lldpRemChassisId] => string(18) "0C 42 A1 04 4A 8B " [lldpRemPortIdSubtype] => string(10) "macAddress" [lldpRemPortId] => string(18) "0C 42 A1 04 4A 8B " [lldpRemPortDesc] => string(23) "Interface 7 as ens3f1" [lldpRemSysName] => string(22) "dps019.plants.ox.ac.uk" [lldpRemSysDesc] => string(99) "Linux dps019.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64" [lldpRemManAddrIfId] => string(1) "7" [lldpRemManAddr] => string(39) "fe80:0000:0000:0000:a381:032e:b521:6bd7" [lldpRemMan] => array( [fe80:0000:0000:0000:a381:032e:b521:6bd7] => array( [lldpRemManAddrIfId] => string(1) "7" ) ) ) ) Get cached Table OID: BRIDGE-MIB::dot1dBasePortIfIndex CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' lldpLocPortEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m1.0917s[0m][0m STDOUT[ lldpLocPortIdSubtype.8 = interfaceName lldpLocPortIdSubtype.1176 = interfaceName lldpLocPortIdSubtype.1184 = interfaceName lldpLocPortIdSubtype.1192 = interfaceName lldpLocPortIdSubtype.1200 = interfaceName lldpLocPortIdSubtype.1208 = interfaceName lldpLocPortIdSubtype.1216 = interfaceName lldpLocPortIdSubtype.1224 = interfaceName lldpLocPortIdSubtype.1232 = interfaceName lldpLocPortIdSubtype.1240 = interfaceName lldpLocPortIdSubtype.1248 = interfaceName lldpLocPortIdSubtype.1256 = interfaceName lldpLocPortIdSubtype.1264 = interfaceName lldpLocPortIdSubtype.1272 = interfaceName lldpLocPortIdSubtype.1280 = interfaceName lldpLocPortIdSubtype.1288 = interfaceName lldpLocPortIdSubtype.1296 = interfaceName lldpLocPortIdSubtype.1304 = interfaceName lldpLocPortIdSubtype.1312 = interfaceName lldpLocPortIdSubtype.1320 = interfaceName lldpLocPortIdSubtype.1328 = interfaceName lldpLocPortIdSubtype.1336 = interfaceName lldpLocPortIdSubtype.1344 = interfaceName lldpLocPortIdSubtype.1352 = interfaceName lldpLocPortIdSubtype.1360 = interfaceName lldpLocPortIdSubtype.1368 = interfaceName lldpLocPortIdSubtype.1376 = interfaceName lldpLocPortIdSubtype.1384 = interfaceName lldpLocPortIdSubtype.1392 = interfaceName lldpLocPortIdSubtype.1400 = interfaceName lldpLocPortIdSubtype.1408 = interfaceName lldpLocPortIdSubtype.1416 = interfaceName lldpLocPortIdSubtype.1424 = interfaceName lldpLocPortIdSubtype.1432 = interfaceName lldpLocPortIdSubtype.1440 = interfaceName lldpLocPortId.8 = "mgmt1/1/1" lldpLocPortId.1176 = "ethernet1/1/1" lldpLocPortId.1184 = "ethernet1/1/2" lldpLocPortId.1192 = "ethernet1/1/3" lldpLocPortId.1200 = "ethernet1/1/4" lldpLocPortId.1208 = "ethernet1/1/5" lldpLocPortId.1216 = "ethernet1/1/6" lldpLocPortId.1224 = "ethernet1/1/7" lldpLocPortId.1232 = "ethernet1/1/8" lldpLocPortId.1240 = "ethernet1/1/9" lldpLocPortId.1248 = "ethernet1/1/10" lldpLocPortId.1256 = "ethernet1/1/11" lldpLocPortId.1264 = "ethernet1/1/12" lldpLocPortId.1272 = "ethernet1/1/13" lldpLocPortId.1280 = "ethernet1/1/14" lldpLocPortId.1288 = "ethernet1/1/15" lldpLocPortId.1296 = "ethernet1/1/16" lldpLocPortId.1304 = "ethernet1/1/17" lldpLocPortId.1312 = "ethernet1/1/18" lldpLocPortId.1320 = "ethernet1/1/19" lldpLocPortId.1328 = "ethernet1/1/20" lldpLocPortId.1336 = "ethernet1/1/21" lldpLocPortId.1344 = "ethernet1/1/22" lldpLocPortId.1352 = "ethernet1/1/23" lldpLocPortId.1360 = "ethernet1/1/24" lldpLocPortId.1368 = "ethernet1/1/25" lldpLocPortId.1376 = "ethernet1/1/26" lldpLocPortId.1384 = "ethernet1/1/27" lldpLocPortId.1392 = "ethernet1/1/28" lldpLocPortId.1400 = "ethernet1/1/29" lldpLocPortId.1408 = "ethernet1/1/30" lldpLocPortId.1416 = "ethernet1/1/31" lldpLocPortId.1424 = "ethernet1/1/32" lldpLocPortId.1432 = "ethernet1/1/33" lldpLocPortId.1440 = "ethernet1/1/34" lldpLocPortDesc.8 = mgmt1/1/1 lldpLocPortDesc.1176 = ethernet1/1/1 lldpLocPortDesc.1184 = ethernet1/1/2 lldpLocPortDesc.1192 = ethernet1/1/3 lldpLocPortDesc.1200 = ethernet1/1/4 lldpLocPortDesc.1208 = ethernet1/1/5 lldpLocPortDesc.1216 = ethernet1/1/6 lldpLocPortDesc.1224 = ethernet1/1/7 lldpLocPortDesc.1232 = ethernet1/1/8 lldpLocPortDesc.1240 = ethernet1/1/9 lldpLocPortDesc.1248 = ethernet1/1/10 lldpLocPortDesc.1256 = ethernet1/1/11 lldpLocPortDesc.1264 = ethernet1/1/12 lldpLocPortDesc.1272 = ethernet1/1/13 lldpLocPortDesc.1280 = ethernet1/1/14 lldpLocPortDesc.1288 = ethernet1/1/15 lldpLocPortDesc.1296 = ethernet1/1/16 lldpLocPortDesc.1304 = ethernet1/1/17 lldpLocPortDesc.1312 = ethernet1/1/18 lldpLocPortDesc.1320 = ethernet1/1/19 lldpLocPortDesc.1328 = ethernet1/1/20 lldpLocPortDesc.1336 = ethernet1/1/21 lldpLocPortDesc.1344 = ethernet1/1/22 lldpLocPortDesc.1352 = ethernet1/1/23 lldpLocPortDesc.1360 = ethernet1/1/24 lldpLocPortDesc.1368 = ethernet1/1/25 lldpLocPortDesc.1376 = ethernet1/1/26 lldpLocPortDesc.1384 = ethernet1/1/27 lldpLocPortDesc.1392 = ethernet1/1/28 lldpLocPortDesc.1400 = ethernet1/1/29 lldpLocPortDesc.1408 = ethernet1/1/30 lldpLocPortDesc.1416 = ethernet1/1/31 lldpLocPortDesc.1424 = ethernet1/1/32 lldpLocPortDesc.1432 = ethernet1/1/33 lldpLocPortDesc.1440 = ethernet1/1/34 ] SNMP STATUS[[0;32mTRUE[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND `ifIndex` = '17' AND `ifDescr` NOT LIKE 'Vlan%'[0m][0m SQL RUNTIME[[0;32m0.00044489s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw009' AND (`remote_ip` IS NULL OR `remote_ip` IN ('0.0.0.0', '::')) AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00014997s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `device_id` FROM `ports` WHERE `deleted` = '0' AND `ifPhysAddress` = '8c04baec10c0' AND `device_id` != '84' LIMIT 1;[0m][0m SQL RUNTIME[[0;32m0.00134110s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw009' AND (`remote_ip` IS NULL OR `remote_ip` IN ('0.0.0.0', '::')) AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00259209s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mINSERT INTO `autodiscovery` (`poller_id`,`remote_hostname`,`last_reason`,`device_id`,`remote_device_id`,`protocol`,`added`) VALUES ('0','ssw009','ok','84','78','XDP',NOW())[0m][0m SQL RUNTIME[[0;32m0.00009704s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m AUTODISCOVERY INSERTED SQL[[0;33mSELECT `port_id` FROM `ports` WHERE (`ifName` = 'ethernet1/1/17' OR `ifDescr` = 'ethernet1/1/17' OR `port_label_short` = 'ethernet1/1/17') AND `device_id` = '78' AND `deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00028110s[0m][0m Discover neighbour: 84 -> lldp, 2078, 1970, ssw009, ethernet1/1/17, Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S3048-ON, , SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw009' AND (`remote_ip` IS NULL OR `remote_ip` IN ('0.0.0.0', '::')) AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009894s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2078' AND `protocol` = 'lldp' AND `remote_hostname` = 'ssw009' AND `remote_port` = 'ethernet1/1/17'[0m][0m SQL RUNTIME[[0;32m0.00019598s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/29' OR `ifDescr` = 'ethernet1/1/29' OR `port_label_short` = 'ethernet1/1/29')[0m][0m SQL RUNTIME[[0;32m0.00042415s[0m][0m Multiple remote IP addresses detect, selected: 192.168.100.114 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00010109s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `device_id` FROM `ports` WHERE `deleted` = '0' AND `ifPhysAddress` = '8c04bad39ac0' AND `device_id` != '84' LIMIT 1;[0m][0m SQL RUNTIME[[0;32m0.00136614s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009513s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mINSERT INTO `autodiscovery` (`poller_id`,`remote_hostname`,`last_reason`,`device_id`,`remote_ip`,`remote_device_id`,`protocol`,`added`) VALUES ('0','ssw007','ok','84','192.168.100.114','86','XDP',NOW())[0m][0m SQL RUNTIME[[0;32m0.00008798s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m AUTODISCOVERY INSERTED SQL[[0;33mSELECT `port_id` FROM `ports` WHERE (`ifName` = 'ethernet1/1/29' OR `ifDescr` = 'ethernet1/1/29' OR `port_label_short` = 'ethernet1/1/29') AND `device_id` = '86' AND `deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00034904s[0m][0m Discover neighbour: 84 -> lldp, 2100, 2172, ssw007, ethernet1/1/29, Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON, , 192.168.100.114 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009394s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2100' AND `protocol` = 'lldp' AND `remote_hostname` = 'ssw007' AND `remote_port` = 'ethernet1/1/29'[0m][0m SQL RUNTIME[[0;32m0.00022483s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/30' OR `ifDescr` = 'ethernet1/1/30' OR `port_label_short` = 'ethernet1/1/30')[0m][0m SQL RUNTIME[[0;32m0.00039911s[0m][0m Multiple remote IP addresses detect, selected: 192.168.100.114 AUTODISCOVERY DEVEL: remote_device_id from cache SQL[[0;33mSELECT `port_id` FROM `ports` WHERE (`ifName` = 'ethernet1/1/30' OR `ifDescr` = 'ethernet1/1/30' OR `port_label_short` = 'ethernet1/1/30') AND `device_id` = '86' AND `deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00022101s[0m][0m Discover neighbour: 84 -> lldp, 2101, 2173, ssw007, ethernet1/1/30, Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON, , 192.168.100.114 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009608s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2101' AND `protocol` = 'lldp' AND `remote_hostname` = 'ssw007' AND `remote_port` = 'ethernet1/1/30'[0m][0m SQL RUNTIME[[0;32m0.00018883s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/31' OR `ifDescr` = 'ethernet1/1/31' OR `port_label_short` = 'ethernet1/1/31')[0m][0m SQL RUNTIME[[0;32m0.00039697s[0m][0m Multiple remote IP addresses detect, selected: 192.168.100.114 AUTODISCOVERY DEVEL: remote_device_id from cache SQL[[0;33mSELECT `port_id` FROM `ports` WHERE (`ifName` = 'ethernet1/1/31' OR `ifDescr` = 'ethernet1/1/31' OR `port_label_short` = 'ethernet1/1/31') AND `device_id` = '86' AND `deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00021791s[0m][0m Discover neighbour: 84 -> lldp, 2102, 2174, ssw007, ethernet1/1/31, Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON, , 192.168.100.114 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00010490s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2102' AND `protocol` = 'lldp' AND `remote_hostname` = 'ssw007' AND `remote_port` = 'ethernet1/1/31'[0m][0m SQL RUNTIME[[0;32m0.00018811s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/32' OR `ifDescr` = 'ethernet1/1/32' OR `port_label_short` = 'ethernet1/1/32')[0m][0m SQL RUNTIME[[0;32m0.00038409s[0m][0m Multiple remote IP addresses detect, selected: 192.168.100.114 AUTODISCOVERY DEVEL: remote_device_id from cache SQL[[0;33mSELECT `port_id` FROM `ports` WHERE (`ifName` = 'ethernet1/1/32' OR `ifDescr` = 'ethernet1/1/32' OR `port_label_short` = 'ethernet1/1/32') AND `device_id` = '86' AND `deleted` = '0'[0m][0m SQL RUNTIME[[0;32m0.00021815s[0m][0m Discover neighbour: 84 -> lldp, 2103, 2175, ssw007, ethernet1/1/32, Dell EMC Networking OS10 Enterprise. Copyright (c) 1999-2020 by Dell Inc. All Rights Reserved. System Description: OS10 Enterprise. OS Version: 10.5.0.4. System Type: S5232F-ON, , 192.168.100.114 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'ssw007' AND `remote_ip` = '192.168.100.114' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009418s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2103' AND `protocol` = 'lldp' AND `remote_hostname` = 'ssw007' AND `remote_port` = 'ethernet1/1/32'[0m][0m SQL RUNTIME[[0;32m0.00020695s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/14' OR `ifDescr` = 'ethernet1/1/14' OR `port_label_short` = 'ethernet1/1/14')[0m][0m SQL RUNTIME[[0;32m0.00038195s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps021.plants.ox.ac.uk' AND `remote_ip` = 'fe80::dcaf:f184:95f9:5cc1' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009489s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `device_id` FROM `ports` WHERE `deleted` = '0' AND `ifPhysAddress` = '98039b977eb7' AND `device_id` != '84' LIMIT 1;[0m][0m SQL RUNTIME[[0;32m0.00134897s[0m][0m SQL[[0;33mSELECT DISTINCT `device_id` FROM `ipv6_addresses` LEFT JOIN `ports` USING (`device_id`, `port_id`) WHERE 1 AND `ipv6_binary` = 'þ€\0\0\0\0\0\0ܯñ„•ù\\Á' AND (`ports`.`deleted` != "1" OR `ports`.`deleted` IS NULL) AND `device_id` != '84'[0m][0m SQL RUNTIME[[0;32m0.00029206s[0m][0m SQL[[0;33mSELECT `device_id` FROM `devices` WHERE `hostname` = 'dps021.plants.ox.ac.uk'[0m][0m SQL RUNTIME[[0;32m0.00014687s[0m][0m SQL[[0;33mSELECT `device_id` FROM `devices` WHERE `sysName` = 'dps021.plants.ox.ac.uk'[0m][0m SQL RUNTIME[[0;32m0.00013113s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps021.plants.ox.ac.uk' AND `remote_ip` = 'fe80::dcaf:f184:95f9:5cc1'[0m][0m SQL RUNTIME[[0;32m0.00008988s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m [0;35m o [1;37mTrying to discover host[0m dps021.plants.ox.ac.uk (fe80::dcaf:f184:95f9:5cc1) through LLDP (xdp) Host dps021.plants.ox.ac.uk resolved as 163.1.37.71, but not same as discovered by protocol fe80::dcaf:f184:95f9:5cc1. Try autodiscover by IP. IP fe80::dcaf:f184:95f9:5cc1 (dps021.plants.ox.ac.uk) not permitted inside $config['autodiscovery']['ip_nets'] in config. SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps021.plants.ox.ac.uk' AND `remote_ip` = 'fe80::dcaf:f184:95f9:5cc1' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00010419s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mINSERT INTO `autodiscovery` (`poller_id`,`remote_hostname`,`last_reason`,`device_id`,`remote_ip`,`protocol`,`added`) VALUES ('0','dps021.plants.ox.ac.uk','no_ip_permit','84','fe80::dcaf:f184:95f9:5cc1','LLDP',NOW())[0m][0m SQL RUNTIME[[0;32m0.00009608s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m AUTODISCOVERY INSERTED Discover neighbour: 84 -> lldp, 2085, , dps021.plants.ox.ac.uk, 98 03 9B 97 7E B7 , Linux dps021.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64, , fe80:0000:0000:0000:dcaf:f184:95f9:5cc1 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps021.plants.ox.ac.uk' AND `remote_ip` = 'fe80::dcaf:f184:95f9:5cc1' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009823s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2085' AND `protocol` = 'lldp' AND `remote_hostname` = 'dps021.plants.ox.ac.uk' AND `remote_port` = '98 03 9B 97 7E B7 '[0m][0m SQL RUNTIME[[0;32m0.00019693s[0m][0m SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '84' AND (`ifName`= 'ethernet1/1/16' OR `ifDescr` = 'ethernet1/1/16' OR `port_label_short` = 'ethernet1/1/16')[0m][0m SQL RUNTIME[[0;32m0.00040388s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps019.plants.ox.ac.uk' AND `remote_ip` = 'fe80::a381:32e:b521:6bd7' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00009704s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `device_id` FROM `ports` WHERE `deleted` = '0' AND `ifPhysAddress` = '0c42a1044a8b' AND `device_id` != '84' LIMIT 1;[0m][0m SQL RUNTIME[[0;32m0.00141001s[0m][0m SQL[[0;33mSELECT DISTINCT `device_id` FROM `ipv6_addresses` LEFT JOIN `ports` USING (`device_id`, `port_id`) WHERE 1 AND `ipv6_binary` = 'þ€\0\0\0\0\0\0£.µ!k×' AND (`ports`.`deleted` != "1" OR `ports`.`deleted` IS NULL) AND `device_id` != '84'[0m][0m SQL RUNTIME[[0;32m0.00031209s[0m][0m SQL[[0;33mSELECT `device_id` FROM `devices` WHERE `hostname` = 'dps019.plants.ox.ac.uk'[0m][0m SQL RUNTIME[[0;32m0.00013995s[0m][0m SQL[[0;33mSELECT `device_id` FROM `devices` WHERE `sysName` = 'dps019.plants.ox.ac.uk'[0m][0m SQL RUNTIME[[0;32m0.00014901s[0m][0m SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps019.plants.ox.ac.uk' AND `remote_ip` = 'fe80::a381:32e:b521:6bd7'[0m][0m SQL RUNTIME[[0;32m0.00009513s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m [0;35m o [1;37mTrying to discover host[0m dps019.plants.ox.ac.uk (fe80::a381:32e:b521:6bd7) through LLDP (xdp) Host dps019.plants.ox.ac.uk resolved as 163.1.37.69, but not same as discovered by protocol fe80::a381:32e:b521:6bd7. Try autodiscover by IP. IP fe80::a381:32e:b521:6bd7 (dps019.plants.ox.ac.uk) not permitted inside $config['autodiscovery']['ip_nets'] in config. SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps019.plants.ox.ac.uk' AND `remote_ip` = 'fe80::a381:32e:b521:6bd7' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00011206s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mINSERT INTO `autodiscovery` (`poller_id`,`remote_hostname`,`last_reason`,`device_id`,`remote_ip`,`protocol`,`added`) VALUES ('0','dps019.plants.ox.ac.uk','no_ip_permit','84','fe80::a381:32e:b521:6bd7','LLDP',NOW())[0m][0m SQL RUNTIME[[0;32m0.00009203s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m AUTODISCOVERY INSERTED Discover neighbour: 84 -> lldp, 2087, , dps019.plants.ox.ac.uk, 0C 42 A1 04 4A 8B , Linux dps019.plants.ox.ac.uk 4.18.0-193.6.3.el8_2.x86_64 #1 SMP Wed Jun 10 11:09:32 UTC 2020 x86_64, , fe80:0000:0000:0000:a381:032e:b521:6bd7 SQL[[0;33mSELECT `autodiscovery`.*, UNIX_TIMESTAMP(`last_checked`) AS `last_checked_unixtime` FROM `autodiscovery` WHERE `poller_id` = '0' AND `remote_hostname` = 'dps019.plants.ox.ac.uk' AND `remote_ip` = 'fe80::a381:32e:b521:6bd7' AND (`remote_device_id` IS NULL OR `remote_device_id` != '84')[0m][0m SQL RUNTIME[[0;32m0.00011802s[0m] SQL ERROR[[0;31mError in query: (Table 'observium.autodiscovery' doesn't exist) 1146[0m][0m SQL[[0;33mSELECT `neighbours`.*, UNIX_TIMESTAMP(`last_change`) AS `last_change_unixtime` FROM `neighbours` WHERE `port_id` = '2087' AND `protocol` = 'lldp' AND `remote_hostname` = 'dps019.plants.ox.ac.uk' AND `remote_port` = '0C 42 A1 04 4A 8B '[0m][0m SQL RUNTIME[[0;32m0.00021791s[0m][0m [0;36m o [1;37mCISCO-CDP-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'ssw006':'161' cdpCache[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0415s[0m][0m STDOUT[ cdpCache = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `neighbours` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00036311s[0m][0m 2078 -> ssw009 () -> ethernet1/1/17 SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '1970'[0m][0m SQL RUNTIME[[0;32m0.00027013s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '1970'[0m][0m SQL RUNTIME[[0;32m0.00018406s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `device_id` = '78'[0m][0m SQL RUNTIME[[0;32m0.00025892s[0m][0m SQL[[0;33mSELECT * FROM `device_graphs` WHERE `device_id` = '78'[0m][0m SQL RUNTIME[[0;32m0.00021696s[0m][0m 2100 -> OS10 (192.168.100.114) -> ethernet1/1/29 2101 -> OS10 (192.168.100.114) -> ethernet1/1/30 2102 -> OS10 (192.168.100.114) -> ethernet1/1/31 2103 -> OS10 (192.168.100.114) -> ethernet1/1/32 2087 -> dps019.plants.ox.ac.uk (fe80::a381:32e:b521:6bd7) -> 0C 42 A1 04 4A 8B 2085 -> dps021.plants.ox.ac.uk (fe80::dcaf:f184:95f9:5cc1) -> 98 03 9B 97 7E B7 2100 -> ssw007 (192.168.100.114) -> ethernet1/1/29 SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2172'[0m][0m SQL RUNTIME[[0;32m0.00021601s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2172'[0m][0m SQL RUNTIME[[0;32m0.00020289s[0m][0m SQL[[0;33mSELECT * FROM `devices` WHERE `device_id` = '86'[0m][0m SQL RUNTIME[[0;32m0.00020194s[0m][0m SQL[[0;33mSELECT * FROM `device_graphs` WHERE `device_id` = '86'[0m][0m SQL RUNTIME[[0;32m0.00021100s[0m][0m 2101 -> ssw007 (192.168.100.114) -> ethernet1/1/30 SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2173'[0m][0m SQL RUNTIME[[0;32m0.00020909s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2173'[0m][0m SQL RUNTIME[[0;32m0.00016212s[0m][0m 2102 -> ssw007 (192.168.100.114) -> ethernet1/1/31 SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2174'[0m][0m SQL RUNTIME[[0;32m0.00021505s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2174'[0m][0m SQL RUNTIME[[0;32m0.00015688s[0m][0m 2103 -> ssw007 (192.168.100.114) -> ethernet1/1/32 SQL[[0;33mSELECT * FROM `ports` WHERE `ports`.`port_id` = '2175'[0m][0m SQL RUNTIME[[0;32m0.00020123s[0m][0m SQL[[0;33mSELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '2175'[0m][0m SQL RUNTIME[[0;32m0.00015688s[0m][0m +----------+----------------+----------------------------------------------------+--------------------+----------------------+---------+ | [37;1mProtocol[0m | [37;1mifName[0m | [37;1mRemote: hostname[0m | [37;1mport[0m | [37;1mplatform[0m | [37;1mversion[0m | +----------+----------------+----------------------------------------------------+--------------------+----------------------+---------+ | LLDP | Ethernet1/1/7 | ssw009 | Ethernet1/1/17 | Dell EMC Networki... | ... | | LLDP | Ethernet1/1/16 | dps019.plants.ox.ac.uk (fe80::a381:32e:b521:6bd7) | 0C 42 A1 04 4A 8B | Linux dps019.plan... | ... | | LLDP | Ethernet1/1/14 | dps021.plants.ox.ac.uk (fe80::dcaf:f184:95f9:5cc1) | 98 03 9B 97 7E B7 | Linux dps021.plan... | ... | | LLDP | Ethernet1/1/29 | ssw007 (192.168.100.114) | Ethernet1/1/29 | Dell EMC Networki... | ... | | LLDP | Ethernet1/1/30 | ssw007 (192.168.100.114) | Ethernet1/1/30 | Dell EMC Networki... | ... | | LLDP | Ethernet1/1/31 | ssw007 (192.168.100.114) | Ethernet1/1/31 | Dell EMC Networki... | ... | | LLDP | Ethernet1/1/32 | ssw007 (192.168.100.114) | Ethernet1/1/32 | Dell EMC Networki... | ... | +----------+----------------+----------------------------------------------------+--------------------+----------------------+---------+ [1;44;96m > $valid[$module][0m[44;36m /opt/observium/includes/discovery/neighbours.inc.php:59 [0m array( [2078] => array( [ssw009] => array( [ethernet1/1/17] => int(1) ) ) [2100] => array( [ssw007-192.168.100.114] => array( [ethernet1/1/29] => int(1) ) ) [2101] => array( [ssw007-192.168.100.114] => array( [ethernet1/1/30] => int(1) ) ) [2102] => array( [ssw007-192.168.100.114] => array( [ethernet1/1/31] => int(1) ) ) [2103] => array( [ssw007-192.168.100.114] => array( [ethernet1/1/32] => int(1) ) ) [2085] => array( [dps021.plants.ox.ac.uk-fe80::dcaf:f184:95f9:5cc1] => array( [98 03 9B 97 7E B7 ] => int(1) ) ) [2087] => array( [dps019.plants.ox.ac.uk-fe80::a381:32e:b521:6bd7] => array( [0C 42 A1 04 4A 8B ] => int(1) ) ) ) [0;36m o [1;37mChanges [0m 7 unchanged [0;36m o [1;37mDuration [0m 3.0749s [0;36m##### [1;37mModule Start: [1;31marp-table[0;36m #####[0m [0m SQL[[0;33mSELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '84' GROUP BY `port_id`[0m][0m SQL RUNTIME[[0;32m0.00022793s[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' ipNetToPhysicalPhysAddress[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0146s[0m][0m STDOUT[ ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.10"] 0:4:96:9b:b4:aa ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.12"] 0:4:96:9b:b4:9e ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.14"] 0:4:96:99:d4:a4 ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.62"] e8:1c:ba:60:b8:d6 ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.142"] 0:50:56:93:8:b4 ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.163"] 0:50:56:93:64:80 ipNetToPhysicalPhysAddress[9][ipv4]["192.168.100.254"] 90:6c:ac:8f:41:71 ipNetToPhysicalPhysAddress[9][ipv6]["fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:eb:cf:75"] 8c:4:ba:eb:cf:75 ipNetToPhysicalPhysAddress[9][ipv6]["fe:80:00:00:00:00:00:00:8e:04:ba:ff:fe:ec:11:75"] 8c:4:ba:ec:11:75 ipNetToPhysicalPhysAddress[45][ipv6]["fe:80:00:00:00:00:00:00:0b:46:43:05:7d:85:c5:23"] ipNetToPhysicalPhysAddress[45][ipv6]["fe:80:00:00:00:00:00:00:a3:81:03:2e:b5:21:6b:d7"] ipNetToPhysicalPhysAddress[45][ipv6]["fe:80:00:00:00:00:00:00:dc:af:f1:84:95:f9:5c:c1"] ipNetToPhysicalPhysAddress[45][ipv6]["fe:80:00:00:00:00:00:00:e8:37:47:f6:06:c3:40:52"] ] SNMP STATUS[[0;32mTRUE[0m][0m Used IP-MIB::ipNetToPhysicalPhysAddress SQL[[0;33mSELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac AS M[0m [0;33m LEFT JOIN ports AS I ON M.port_id = I.port_id[0m [0;33m WHERE I.device_id = '84'[0m][0m SQL RUNTIME[[0;32m0.00042796s[0m][0m ....... SQL[[0;33mINSERT INTO `ip_mac` (`port_id`,`mac_address`,`ip_address`,`ip_version`) VALUES ('2071','8c04baebcf75','fe80:0000:0000:0000:8e04:baff:feeb:cf75','6')[0m][0m SQL RUNTIME[[0;32m0.00050902s[0m][0m Added MAC address 8c:04:ba:eb:cf:75 for fe80:0000:0000:0000:8e04:baff:feeb:cf75 +. [0;36m o [1;37mDuration [0m 0.0189s [0;36m##### [1;37mModule Start: [1;31mjunose-atm-vp[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0002s [0;36m##### [1;37mModule Start: [1;31mbgp-peers[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmpget -v2c -c *** -Pud -OQUv -m BGP4-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' bgpLocalAs.0[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0095s[0m][0m STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m No BGP on host SQL[[0;33mSELECT * FROM `bgpPeers` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00028896s[0m][0m [0;36m o [1;37mDuration [0m 0.0123s [0;36m##### [1;37mModule Start: [1;31mmac-accounting[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0003s [0;36m##### [1;37mModule Start: [1;31msla[0;36m #####[0m [0m [0;36m o [1;37mDISMAN-PING-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' pingCtlEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0471s[0m][0m STDOUT[ pingCtlEntry = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `slas` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00032282s[0m][0m [0;36m o [1;37mDuration [0m 0.0498s Module [lsp] disabled globally by config in process [discovery]. [0;36m##### [1;37mModule Start: [1;31mpseudowires[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `pseudowires` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00019288s[0m][0m [0;36m o [1;37mPW-STD-MIB [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' pwID[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0161s[0m][0m STDOUT[ pwID = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m [0;36m o [1;37mDuration [0m 0.0187s [0;36m##### [1;37mModule Start: [1;31mvirtual-machines[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0006s [0;36m##### [1;37mModule Start: [1;31mcisco-cbqos[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `ports_cbqos` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00030017s[0m][0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m CISCO-CLASS-BASED-QOS-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'ssw006':'161' cbQosIfType[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0584s[0m][0m STDOUT[ cbQosIfType = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m QoS not configured. [0;36m o [1;37mDuration [0m 0.0605s [0;36m##### [1;37mModule Start: [1;31mucd-diskio[0;36m #####[0m [0m CMD[[0;33m/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ssw006':'161' diskIOEntry[0m] [0m CMD EXITCODE[[0;32m0[0m] CMD RUNTIME[[0;32m0.0108s[0m][0m STDOUT[ diskIOEntry = No Such Object available on this agent at this OID ] SNMP STATUS[[0;31mFALSE[0m][0m SNMP ERROR[[0;31m#1000 - Failed response[0m][0m SQL[[0;33mSELECT * FROM `ucd_diskio` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00032806s[0m][0m [0;36m o [1;37mDuration [0m 0.0129s [0;36m##### [1;37mModule Start: [1;31mwifi[0;36m #####[0m [0m SQL[[0;33mSELECT * FROM `wifi_radios` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00016308s[0m][0m SQL[[0;33mSELECT * FROM `wifi_wlans` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00014901s[0m][0m SQL[[0;33mSELECT * FROM `wifi_aps` WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00013304s[0m][0m [0;36m o [1;37mDuration [0m 0.0012s [0;36m##### [1;37mModule Start: [1;31mp2p-radios[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0001s [0;36m##### [1;37mModule Start: [1;31mgraphs[0;36m #####[0m [0m [0;36m o [1;37mDuration [0m 0.0003s Module [raid] disabled globally by config in process [discovery]. [0;32m o [1;37mModules Disabled [0m lsp, raid [0;32m o [1;37mModules Enabled [0m os, mibs, ports, ports-stack, vlans, oids, cisco-vrf, ip-addresses, processors, mempools, inventory, printersupplies, sensors,storage, neighbours, arp-table, junose-atm-vp, bgp-peers, mac-accounting, sla, pseudowires, virtual-machines, cisco-cbqos,ucd-diskio, wifi, p2p-radios, graphs SQL[[0;33mSELECT `device_state` FROM `devices` WHERE `device_id` = '84';[0m][0m SQL RUNTIME[[0;32m0.00019598s[0m][0m SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`type` ='network',`last_discovered_timetaken` ='4.7667',`force_discovery` ='0',`device_state` ='a:9:{s:2:\"la\";a:3:{s:4:\"1min\";d:0.16;s:4:\"5min\";d:0.31;s:5:\"15min\";d:0.33000000000000002;}s:8:\"ucd_load\";d:0.31;s:15:\"poller_mod_perf\";a:28:{s:6:\"system\";d:0.27150000000000002;s:2:\"os\";d:0.092799999999999994;s:7:\"sensors\";d:0.1225;s:6:\"status\";d:0.34089999999999998;s:7:\"counter\";d:0.001;s:10:\"processors\";d:0.3417;s:8:\"mempools\";d:0.1145;s:7:\"storage\";d:0.033300000000000003;s:8:\"netstats\";d:0.2722;s:7:\"ucd-mib\";d:0.129;s:13:\"ipSystemStats\";d:0.077399999999999997;s:5:\"ports\";d:2.4409999999999998;s:9:\"bgp-peers\";d:0.017600000000000001;s:15:\"printersupplies\";d:0.00080000000000000004;s:10:\"ucd-diskio\";d:0.00029999999999999997;s:4:\"wifi\";d:0.0015;s:10:\"p2p-radios\";d:0.00050000000000000001;s:4:\"ospf\";d:0.00040000000000000002;s:3:\"sla\";d:0.00080000000000000004;s:11:\"pseudowires\";d:0.00089999999999999998;s:14:\"mac-accounting\";d:0.00059999999999999995;s:12:\"loadbalancer\";d:0.00029999999999999997;s:15:\"entity-physical\";d:0.00020000000000000001;s:12:\"applications\";d:0.00050000000000000001;s:9:\"fdb-table\";d:0.11070000000000001;s:6:\"graphs\";d:0.035999999999999997;s:4:\"oids\";d:0.00080000000000000004;s:6:\"probes\";d:0.0060000000000000001;}s:10:\"ucd_ss_cpu\";a:8:{s:12:\"ssCpuRawUser\";a:1:{s:4:\"perc\";d:3.9379772583280537;}s:12:\"ssCpuRawNice\";a:1:{s:4:\"perc\";i:0;}s:14:\"ssCpuRawSystem\";a:1:{s:4:\"perc\";d:4.2439561172429894;}s:12:\"ssCpuRawIdle\";a:1:{s:4:\"perc\";d:91.624929140684912;}s:17:\"ssCpuRawInterrupt\";a:1:{s:4:\"perc\";i:0;}s:15:\"ssCpuRawSoftIRQ\";a:1:{s:4:\"perc\";d:0.12644636366667777;}s:14:\"ssCpuRawKernel\";a:1:{s:4:\"perc\";i:0;}s:12:\"ssCpuRawWait\";a:1:{s:4:\"perc\";d:0.066691120077361693;}}s:7:\"ucd_mem\";a:8:{s:10:\"swap_total\";s:7:\"1637552\";s:10:\"swap_avail\";s:7:\"1637552\";s:9:\"mem_total\";s:8:\"16375556\";s:9:\"mem_avail\";s:8:\"14026560\";s:10:\"mem_shared\";s:4:\"5224\";s:10:\"mem_buffer\";s:5:\"24200\";s:10:\"mem_cached\";s:6:\"465116\";s:8:\"mem_used\";i:1859680;}s:17:\"poller_ports_perf\";a:1:{s:4:\"vlan\";d:0.14517092704772949;}s:14:\"poller_history\";a:217:{i:1594639565;d:4.6044999999999998;i:1594639285;d:7.1417000000000002;i:1594639272;d:4.9314999999999998;i:1594638969;d:5.3898000000000001;i:1594638678;d:5.0373999999999999;i:1594638380;d:4.1772;i:1594638327;d:4.1322999999999999;i:1594638058;d:4.2233000000000001;i:1594637771;d:7.3163;i:1594637469;d:5.4912999999999998;i:1594637161;d:4.3186999999999998;i:1594636883;d:7.5815999999999999;i:1594636570;d:3.2904;i:1594636274;d:4.7660999999999998;i:1594635978;d:5.5335000000000001;i:1594635671;d:3.8639000000000001;i:1594635376;d:5.5331000000000001;i:1594635081;d:4.4196999999999997;i:1594634782;d:4.8639999999999999;i:1594634476;d:4.2020999999999997;i:1594634178;d:4.3888999999999996;i:1594633866;d:4.1397000000000004;i:1594633577;d:5.1928000000000001;i:1594633275;d:4.3616000000000001;i:1594632970;d:4.4740000000000002;i:1594632679;d:5.2546999999999997;i:1594632367;d:3.7987000000000002;i:1594632076;d:5.0922000000000001;i:1594631767;d:4.2564000000000002;i:1594631480;d:6.3223000000000003;i:1594631175;d:3.9428000000000001;i:1594630876;d:4.6474000000000002;i:1594630576;d:4.5167000000000002;i:1594630270;d:4.3209999999999997;i:1594629980;d:5.2466999999999997;i:1594629666;d:3.8557999999999999;i:1594629377;d:5.5084;i:1594629075;d:3.6842000000000001;i:1594628768;d:4.2196999999999996;i:1594628470;d:4.8728999999999996;i:1594628170;d:4.8902999999999999;i:1594627876;d:5.1169000000000002;i:1594627569;d:4.4175000000000004;i:1594627276;d:5.1546000000000003;i:1594626974;d:4.0965999999999996;i:1594626668;d:4.5914999999999999;i:1594626375;d:4.8464999999999998;i:1594626069;d:4.1395999999999997;i:1594625774;d:4.7027000000000001;i:1594625465;d:4.2396000000000003;i:1594625180;d:6.6498999999999997;i:1594624866;d:3.2136;i:1594624578;d:5.4897;i:1594624266;d:3.4386000000000001;i:1594623976;d:5.3605999999999998;i:1594623676;d:4.5556999999999999;i:1594623373;d:4.2135999999999996;i:1594623077;d:4.7182000000000004;i:1594622765;d:4.1159999999999997;i:1594622479;d:6.3164999999999996;i:1594622167;d:2.9817999999999998;i:1594621879;d:5.3072999999999997;i:1594621569;d:3.6497000000000002;i:1594621263;d:4.6866000000000003;i:1594620979;d:6.5007000000000001;i:1594620673;d:3.3864999999999998;i:1594620375;d:4.1421000000000001;i:1594620076;d:4.8571999999999997;i:1594619772;d:4.2542999999999997;i:1594619473;d:4.6802000000000001;i:1594619172;d:4.4635999999999996;i:1594618874;d:4.6289999999999996;i:1594618572;d:4.4126000000000003;i:1594618277;d:4.8327;i:1594617964;d:3.9870999999999999;i:1594617676;d:5.8452999999999999;i:1594617373;d:4.157;i:1594617073;d:4.6840999999999999;i:1594616776;d:4.5213999999999999;i:1594616477;d:4.2610000000000001;i:1594616165;d:3.6993;i:1594615881;d:6.3318000000000003;i:1594615566;d:3.1709999999999998;i:1594615278;d:5.5994000000000002;i:1594614963;d:3.7625999999999999;i:1594614682;d:6.7348999999999997;i:1594614372;d:3.4165999999999999;i:1594614069;d:4.4097;i:1594613777;d:5.0430000000000001;i:1594613457;d:4.0713999999999997;i:1594613182;d:6.9320000000000004;i:1594612873;d:3.0589;i:1594612568;d:4.7507999999999999;i:1594612277;d:4.9471999999999996;i:1594611971;d:4.0678999999999998;i:1594611665;d:4.4828999999999999;i:1594611381;d:6.5880999999999998;i:1594611067;d:3.1067999999999998;i:1594610775;d:5.6029;i:1594610466;d:3.9824000000000002;i:1594610179;d:6.6596000000000002;i:1594609865;d:3.3172999999999999;i:1594609578;d:5.8041999999999998;i:1594609266;d:3.9851999999999999;i:1594608974;d:5.2968000000000002;i:1594608676;d:4.3254999999999999;i:1594608378;d:4.4592000000000001;i:1594608071;d:3.9502000000000002;i:1594607771;d:4.6761999999999997;i:1594607477;d:5.0331999999999999;i:1594607168;d:4.2355999999999998;i:1594606876;d:5.2450000000000001;i:1594606576;d:4.1877000000000004;i:1594606266;d:4.4077000000000002;i:1594605984;d:6.5168999999999997;i:1594605665;d:3.2768999999999999;i:1594605377;d:5.4880000000000004;i:1594605073;d:3.6680000000000001;i:1594604775;d:4.4991000000000003;i:1594604466;d:3.9205999999999999;i:1594604178;d:5.6497999999999999;i:1594603872;d:3.7738;i:1594603573;d:4.5765000000000002;i:1594603255;d:4.3365999999999998;i:1594602980;d:7.2706999999999997;i:1594602664;d:3.3713000000000002;i:1594602379;d:5.6752000000000002;i:1594602077;d:3.5207000000000002;i:1594601770;d:4.0736999999999997;i:1594601476;d:4.8049999999999997;i:1594601172;d:4.7034000000000002;i:1594600875;d:4.6280999999999999;i:1594600565;d:3.9599000000000002;i:1594600279;d:6.4269999999999996;i:1594599974;d:4.0572999999999997;i:1594599672;d:4.3940000000000001;i:1594599370;d:4.4114000000000004;i:1594599064;d:5.0792999999999999;i:1594598777;d:6.2901999999999996;i:1594598480;d:3.3079999999999998;i:1594598165;d:4.0221;i:1594597877;d:5.7999000000000001;i:1594597564;d:3.6528;i:1594597277;d:5.7122999999999999;i:1594596964;d:3.9104999999999999;i:1594596679;d:6.3175999999999997;i:1594596369;d:3.4275000000000002;i:1594596077;d:5.0387000000000004;i:1594595777;d:4.298;i:1594595481;d:3.9977999999999998;i:1594595166;d:3.5184000000000002;i:1594594883;d:6.5016999999999996;i:1594594573;d:3.8319000000000001;i:1594594278;d:4.7549999999999999;i:1594593973;d:3.5451000000000001;i:1594593670;d:4.5628000000000002;i:1594593376;d:4.7417999999999996;i:1594593065;d:4.1326999999999998;i:1594592778;d:5.7354000000000003;i:1594592472;d:3.9397000000000002;i:1594592189;d:5.1334999999999997;i:1594591950;d:2.5062000000000002;i:1594591875;d:4.5526999999999997;i:1594591571;d:3.7275;i:1594591281;d:5.0118;i:1594590971;d:3.3799999999999999;i:1594590683;d:5.5513000000000003;i:1594590371;d:4.1155999999999997;i:1594590072;d:5.1212999999999997;i:1594589776;d:4.9364999999999997;i:1594589472;d:4.3689999999999998;i:1594589175;d:5.1158000000000001;i:1594588872;d:4.0960000000000001;i:1594588576;d:4.8516000000000004;i:1594588272;d:4.0945999999999998;i:1594587980;d:4.7195999999999998;i:1594587667;d:3.9988999999999999;i:1594587380;d:5.7515000000000001;i:1594587064;d:4.0194999999999999;i:1594586780;d:6.6978999999999997;i:1594586467;d:3.5676000000000001;i:1594586176;d:4.7800000000000002;i:1594585871;d:3.6457000000000002;i:1594585562;d:4.8384999999999998;i:1594585278;d:6.6364999999999998;i:1594584966;d:3.2021999999999999;i:1594584678;d:5.6482999999999999;i:1594584373;d:3.3978000000000002;i:1594584069;d:4.6978999999999997;i:1594583776;d:5.0867000000000004;i:1594583468;d:4.0693000000000001;i:1594583176;d:4.8895;i:1594582875;d:4.3605999999999998;i:1594582570;d:4.4444999999999997;i:1594582277;d:4.9465000000000003;i:1594581969;d:4.4297000000000004;i:1594581675;d:5.0349000000000004;i:1594581376;d:4.1822999999999997;i:1594581074;d:4.3817000000000004;i:1594580772;d:4.4855999999999998;i:1594580477;d:4.9619999999999997;i:1594580169;d:4.1406999999999998;i:1594579876;d:4.9349999999999996;i:1594579569;d:4.2195;i:1594579277;d:5.0972999999999997;i:1594578967;d:4.0098000000000003;i:1594578677;d:5.1759000000000004;i:1594578369;d:4.3514999999999997;i:1594578075;d:5.3280000000000003;i:1594577770;d:4.2381000000000002;i:1594577478;d:5.3544999999999998;i:1594577167;d:3.4083000000000001;i:1594576877;d:5.8742999999999999;i:1594576574;d:3.4175;i:1594576275;d:4.3136999999999999;i:1594575955;d:4.0743;i:1594575675;d:8.3748000000000005;}s:17:\"discovery_history\";a:7:{i:1594639617;d:4.7667000000000002;i:1594639230;d:5.2438000000000002;i:1594638309;d:4.7506000000000004;i:1594634714;d:4.7824;i:1594594903;d:4.5194000000000001;i:1594591936;d:4.9135;i:1594575666;d:8.5762999999999998;}s:18:\"discovery_mod_perf\";a:28:{s:2:\"os\";d:0.053400000000000003;s:4:\"mibs\";d:0.067400000000000002;s:5:\"ports\";d:0.2087;s:11:\"ports-stack\";d:0.1021;s:5:\"vlans\";d:0.23699999999999999;s:11:\"ports_vlans\";N;s:4:\"oids\";d:0.00089999999999999998;s:9:\"cisco-vrf\";d:0.00040000000000000002;s:12:\"ip-addresses\";d:0.098599999999999993;s:10:\"processors\";d:0.062899999999999998;s:8:\"mempools\";d:0.079500000000000001;s:9:\"inventory\";d:0.28189999999999998;s:15:\"printersupplies\";d:0.00069999999999999999;s:7:\"sensors\";d:0.29299999999999998;s:7:\"storage\";d:0.0235;s:10:\"neighbours\";d:3.0749;s:9:\"arp-table\";d:0.0189;s:13:\"junose-atm-vp\";d:0.00020000000000000001;s:9:\"bgp-peers\";d:0.0123;s:14:\"mac-accounting\";d:0.00029999999999999997;s:3:\"sla\";d:0.049799999999999997;s:11:\"pseudowires\";d:0.018700000000000001;s:16:\"virtual-machines\";d:0.00059999999999999995;s:11:\"cisco-cbqos\";d:0.060499999999999998;s:10:\"ucd-diskio\";d:0.0129;s:4:\"wifi\";d:0.0011999999999999999;s:10:\"p2p-radios\";d:0.0001;s:6:\"graphs\";d:0.00029999999999999997;}}' WHERE `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00085092s[0m][0m [0;32m##### [1;37mssw006 [84] completed discovery modules at 2020-07-13 12:27:02[0;32m #####[0m [0m [0;32m o [1;37mDiscovery time [0m 4.7667 seconds SQL[[0;33mDELETE FROM `observium_processes` WHERE `process_pid` = '655' AND `process_name` = 'discovery.php' AND `device_id` = '84'[0m][0m SQL RUNTIME[[0;32m0.00044012s[0m][0m [1;37m##### [1;37m[1;37mFinished discovery run at 2020-07-13 12:27:02[1;37m #####[0m [0m SQL[[0;33mSELECT * FROM `groups` ORDER BY `entity_type`[0m][0m SQL RUNTIME[[0;32m0.00012994s[0m][0m SQL[[0;33mSELECT * FROM `groups_assoc`[0m][0m SQL RUNTIME[[0;32m0.00012112s[0m][0m SQL[[0;33mSELECT * FROM `alert_tests` WHERE 1[0m][0m SQL RUNTIME[[0;32m0.00014210s[0m][0m Cached 7 alert rules. SQL[[0;33mSELECT * FROM `alert_assoc`[0m][0m SQL RUNTIME[[0;32m0.00012183s[0m][0m SQL[[0;33mSELECT `device_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `devices` WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1)))[0m][0m SQL RUNTIME[[0;32m0.00031209s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '1'[0m][0m SQL RUNTIME[[0;32m0.00042796s[0m][0m Alert Checker 'Device down': 80 existing, 80 new entries (+0/-0). SQL[[0;33mSELECT `status_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `status` LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1))) AND `status_deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00115800s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '2'[0m][0m SQL RUNTIME[[0;32m0.00177503s[0m][0m Alert Checker 'Status is ALERT! ': 584 existing, 584 new entries (+0/-0). SQL[[0;33mSELECT `status_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `status` LEFT JOIN `devices` ON (`status`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1))) AND `status_deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00105381s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '3'[0m][0m SQL RUNTIME[[0;32m0.00175714s[0m][0m Alert Checker 'Status is WARN!': 584 existing, 584 new entries (+0/-0). SQL[[0;33mSELECT `sensor_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1 AND `sensor_class` = 'fanspeed'))) AND `sensor_deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00086689s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '4'[0m][0m SQL RUNTIME[[0;32m0.00093389s[0m][0m Alert Checker 'Fanspeed is out of threshold': 248 existing, 248 new entries (+0/-0). SQL[[0;33mSELECT `sensor_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `sensors` LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1 AND `sensor_class` = 'temperature'))) AND `sensor_deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00068998s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '5'[0m][0m SQL RUNTIME[[0;32m0.00056481s[0m][0m Alert Checker 'Temperature out of threshold': 130 existing, 130 new entries (+0/-0). SQL[[0;33mSELECT `port_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1 AND `ifType` = 'ethernetCsmacd'))) AND `deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00365114s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '6'[0m][0m SQL RUNTIME[[0;32m0.00294685s[0m][0m Alert Checker 'Traffic exceeds 95%': 953 existing, 953 new entries (+0/-0). SQL[[0;33mSELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports` LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE ( `ports`.`ifType` = 'ethernetCsmacd') AND `ports`.`deleted` != '1'[0m][0m SQL RUNTIME[[0;32m0.00227714s[0m][0m SQL[[0;33mSELECT * FROM `alert_table` WHERE `alert_test_id` = '8'[0m][0m SQL RUNTIME[[0;32m0.00277901s[0m][0m Alert Checker 'Port has encountered errors': 953 existing, 953 new entries (+0/-0). ./discovery.php: ssw006 - 1 devices discovered in 4.870 secs SQL[[0;33mSELECT * FROM `observium_processes` WHERE `process_start` < '1594625217'[0m][0m SQL RUNTIME[[0;32m0.00014687s[0m][0m NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. [1;37m o [1;37mDevices Discovered [0m 1 [1;37m o [1;37mDiscovery Time [0m 4.870 secs [1;37m o [1;37mMemory usage [0m 22MB (peak: 22MB) [1;37m o [1;37mMySQL Usage [0m Cell[83/0.028s] Row[135/0.047s] Rows[128/0.065s] Column[3/0.001s] Update[45/0.029s] Insert[6/0.005s] Delete[1/0.001s] [1;37m o [1;37mRRDTool Usage [0m