DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0106s]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: http://svn.observium.org/svn/observium/trunk
Repository Root: http://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 10393
Node Kind: directory
Schedule: normal
Last Changed Author: mike
Last Changed Rev: 10393
Last Changed Date: 2020-04-24 17:41:08 +0200 (Fri, 24 Apr 2020)

]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00025511s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00005698s]

SQL[SET SESSION `sql_mode` = 'NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00003719s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ERROR_FOR_DIVISION_BY_ZERO

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00009799s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00010109s]

CMD[/bin/hostname -f]

CMD EXITCODE[0]
CMD RUNTIME[0.0047s]
STDOUT[
lnx98.fqdn.local
]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                          Observium Professional 20.4.10393
                                   http://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.0145s]
STDOUT[
Linux|3.10.0-1062.18.1.el7.x86_64|amd64|CentOS|7|vmware|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0029s]
STDOUT[
Python 2.7.5
]

SQL[SELECT version();]
SQL RUNTIME[0.00015807s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0043s]
STDOUT[
NET-SNMP version: 5.7.2
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0053s]
STDOUT[
RRDtool 1.7.1  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/sbin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0023s]
STDOUT[
/usr/sbin/fping: Version 3.10
/usr/sbin/fping: comments to david@schweikert.ch
]

CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0024s]
STDOUT[

]

CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0262s]
STDOUT[
Apache/2.4.41
]

CMD[date "+%:z"]

CMD EXITCODE[0]
CMD RUNTIME[0.0019s]
CMD EXITDELAY[10ms]
STDOUT[
+02:00
]

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00014496s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00007105s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00044894s]

#####  Software versions  #####

 o OS                   Linux 3.10.0-1062.18.1.el7.x86_64 [amd64] (CentOS 7)
 o Apache               2.4.41
 o PHP                  7.3.17
 o Python               2.7.5
 o MySQL                10.3.22-MariaDB-log (extension: mysqli 5.0.12-dev)
 o SNMP                 NET-SNMP 5.7.2
 o RRDtool              1.7.1
 o Fping                3.10 (IPv4 only)

#####  Memory Limit  #####

 o PHP                  512MB

#####  MySQL mode  #####

 o MySQL                NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8

#####  Timezones info  #####

 o Date                 Friday, 24-Apr-20 18:10:53 CEST
 o PHP                  +02:00
 o MySQL                +02:00

#####  Starting discovery run at 2020-04-24 18:10:53  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'rac-vm03%' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.00035501s]

CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' sysObjectID.0 sysUpTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0102s]
STDOUT[
sysObjectID.0 = enterprises.674.10892.5
sysUpTime.0 = 0:3:53:21.38
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '429']
SQL RUNTIME[0.00023317s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '429']
SQL RUNTIME[0.00012994s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`)  VALUES ('7141','discovery.php','22436','0','php ./discovery.php -h rac-vm03* -d','1587744653','429')]
SQL RUNTIME[0.00110912s]
#####  rac-vm03.fqdn.local [429]  #####

 o OS Type              drac
 o SNMP Version         v2c
 o Last discovery       2020-04-24 17:09:11
 o Last duration        4.13 seconds

#####  Module Start: os  #####


CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0104s]
STDOUT[

]
SNMP STATUS[FALSE]
SNMP ERROR[#1 - Empty response]

CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0157s]
STDOUT[
.1.3.6.1.4.1.674.10892.5
]
SNMP STATUS[TRUE]
Duplicate sysObjectID '.1.3.6.1.4.1.6876.4.1' in definitions for OSes: vmware and vmware!
Duplicate sysObjectID '.1.3.6.1.4.1.6876.4.7' in definitions for OSes: vmware and vmware!
Duplicate sysObjectID '.1.3.6.1.4.1.19746.3.1' in definitions for OSes: datadomain and datadomain!
Duplicate sysObjectID '.1.3.6.1.4.1.12740.17.1' in definitions for OSes: equallogic and equallogic!
Duplicate sysObjectID '.1.3.6.1.4.1.12740.12.1.1.0' in definitions for OSes: equallogic and equallogic!
+-------------+--------------------------+
| OID         |                          |
+-------------+--------------------------+
| sysDescr    |                          |
| sysObjectID | .1.3.6.1.4.1.674.10892.5 |
+-------------+--------------------------+

 o Detect OS matched (drac: Dell iDRAC): 
+-------------+-------------------------+--------------------------+
| OID         | Matched definition      |                          |
+-------------+-------------------------+--------------------------+
| sysObjectID | .1.3.6.1.4.1.674.10892. | .1.3.6.1.4.1.674.10892.5 |
+-------------+-------------------------+--------------------------+


 o Duration             0.0461s

#####  Module Start: mibs  #####


CMD[/usr/bin/snmptranslate -On -Pu -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'SNMPv2-MIB::sysORID']

CMD EXITCODE[0]
CMD RUNTIME[0.0087s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'SNMPv2-MIB::sysORID' -> '.1.3.6.1.2.1.1.9.1.2'

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUsn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' .1.3.6.1.2.1.1.9.1.2]

CMD EXITCODE[0]
CMD RUNTIME[0.0119s]
STDOUT[
.1.3.6.1.2.1.1.9.1.2.1 = .1.3.6.1.6.3.1
.1.3.6.1.2.1.1.9.1.2.2 = .1.3.6.1.6.3.16.2.2.1
.1.3.6.1.2.1.1.9.1.2.3 = .1.3.6.1.2.1.49
.1.3.6.1.2.1.1.9.1.2.4 = .1.3.6.1.2.1.4
.1.3.6.1.2.1.1.9.1.2.5 = .1.3.6.1.2.1.50
.1.3.6.1.2.1.1.9.1.2.6 = .1.3.6.1.6.3.11.3.1.1
.1.3.6.1.2.1.1.9.1.2.7 = .1.3.6.1.6.3.15.2.1.1
.1.3.6.1.2.1.1.9.1.2.8 = .1.3.6.1.6.3.10.3.1.1
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' sysORDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.011s]
STDOUT[
sysORDescr.1 = The MIB module for SNMPv2 entities
sysORDescr.2 = View-based Access Control Model for SNMP.
sysORDescr.3 = The MIB module for managing TCP implementations
sysORDescr.4 = The MIB module for managing IP and ICMP implementations
sysORDescr.5 = The MIB module for managing UDP implementations
sysORDescr.6 = The MIB for Message Processing and Dispatching.
sysORDescr.7 = The management information definitions for the SNMP User-based Security Model.
sysORDescr.8 = The SNMP Management Architecture MIB.
]
SNMP STATUS[TRUE]
 o MIBs discovered      TCP-MIB UDP-MIB 
+-----------------------+--------------------+---------+---------------------+
| Identity              | MIB                | Source  | Status              |
+-----------------------+--------------------+---------+---------------------+
| .1.3.6.1.6.3.1        | SNMPv2-MIB         | sysORID | MIB already defined |
| .1.3.6.1.2.1.4        | IP-MIB             | sysORID | MIB already defined |
| .1.3.6.1.2.1.49       | TCP-MIB            | sysORID | MIB added           |
| .1.3.6.1.2.1.50       | UDP-MIB            | sysORID | MIB added           |
| .1.3.6.1.6.3.10.3.1.1 | SNMP-FRAMEWORK-MIB | sysORID | MIB already defined |
| .1.3.6.1.6.3.16.2.2.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.11.3.1.1 | -                  | sysORID | Unknown Identity    |
| .1.3.6.1.6.3.15.2.1.1 | -                  | sysORID | Unknown Identity    |
+-----------------------+--------------------+---------+---------------------+


 o Duration             0.0387s

#####  Module Start: ports  #####

 o Caching OIDs         
SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '429' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00029016s]
ifDescr 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0121s]
STDOUT[
ifDescr.1 = lo
ifDescr.9 = bond0
]
SNMP STATUS[TRUE]
ifAlias 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifAlias]

CMD EXITCODE[0]
CMD RUNTIME[0.0143s]
STDOUT[
ifAlias.1 = 
ifAlias.9 = 
]
SNMP STATUS[TRUE]
ifName 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifName]

CMD EXITCODE[0]
CMD RUNTIME[0.012s]
STDOUT[
ifName.1 = lo
ifName.9 = bond0
]
SNMP STATUS[TRUE]
ifType 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifType]

CMD EXITCODE[0]
CMD RUNTIME[0.0108s]
STDOUT[
ifType.1 = softwareLoopback
ifType.9 = ethernetCsmacd
]
SNMP STATUS[TRUE]
ifOperStatus 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifOperStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0111s]
STDOUT[
ifOperStatus.1 = up
ifOperStatus.9 = up
]
SNMP STATUS[TRUE]



  /opt/observium/includes/discovery/ports.inc.php:45 
array(
  [1] => array(
           [ifDescr]      => string(2) "lo"
           [ifAlias]      => string(0) ""
           [ifName]       => string(2) "lo"
           [ifType]       => string(16) "softwareLoopback"
           [ifOperStatus] => string(2) "up"
         )
  [9] => array(
           [ifDescr]      => string(5) "bond0"
           [ifAlias]      => string(0) ""
           [ifName]       => string(5) "bond0"
           [ifType]       => string(14) "ethernetCsmacd"
           [ifOperStatus] => string(2) "up"
         )
)
 o Caching DB           
SQL[SELECT * FROM `ports` WHERE `device_id` = '429']
SQL RUNTIME[0.00040507s]
2 ports
 o Discovering ports    ..
+---------+---------+--------+---------+------------------+-------------+---------+
| ifIndex | ifDescr | ifName | ifAlias | ifType           | Oper Status | Ignored |
+---------+---------+--------+---------+------------------+-------------+---------+
| 1       | lo      | lo     | ...     | softwareLoopback | up          | no      |
| 9       | bond0   | bond0  | ...     | ethernetCsmacd   | up          | no      |
+---------+---------+--------+---------+------------------+-------------+---------+


 o Duration             0.0697s

#####  Module Start: ports-stack  #####


SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '429']
SQL RUNTIME[0.00028801s]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ifStackStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0149s]
STDOUT[
ifStackStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


 o Duration             0.0169s

#####  Module Start: vlans  #####


SQL[SELECT * FROM `vlans` WHERE `device_id` = '429';]
SQL RUNTIME[0.00033998s]

SQL[SELECT * FROM `ports_vlans` WHERE `device_id` = '429';]
SQL RUNTIME[0.00014114s]


 o Duration             0.0015s

#####  Module Start: oids  #####


SQL[SELECT * FROM  `oids_entries` LEFT JOIN `oids` USING(`oid_id`) WHERE `device_id` = '429']
SQL RUNTIME[0.00017500s]

SQL[SELECT * FROM `oids` WHERE `oid_autodiscover` = '1']
SQL RUNTIME[0.00010800s]

 o Duration             0.0006s

#####  Module Start: cisco-vrf  #####


 o Duration             0.0004s

#####  Module Start: ip-addresses  #####

 o IP-MIB               
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAdEntIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0161s]
STDOUT[
ipAdEntIfIndex.127.0.0.1 = 1
ipAdEntIfIndex.192.168.138.133 = 9
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAdEntNetMask]

CMD EXITCODE[0]
CMD RUNTIME[0.0271s]
STDOUT[
ipAdEntNetMask.127.0.0.1 = 255.0.0.0
ipAdEntNetMask.192.168.138.133 = 255.255.254.0
]
SNMP STATUS[TRUE]
Added 127.0.0.1
.Added 192.168.138.133
.
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAddressIfIndex]

CMD EXITCODE[0]
CMD RUNTIME[0.0126s]
STDOUT[
ipAddressIfIndex.ipv4."127.0.0.1" = 1
ipAddressIfIndex.ipv4."192.168.138.133" = 9
ipAddressIfIndex.ipv4."192.168.139.255" = 9
ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = 1
ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:5a:8a:5a:ff:fe:f8:fc:0c" = 9
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAddressType]

CMD EXITCODE[0]
CMD RUNTIME[0.0133s]
STDOUT[
ipAddressType.ipv4."127.0.0.1" = unicast
ipAddressType.ipv4."192.168.138.133" = unicast
ipAddressType.ipv4."192.168.139.255" = broadcast
ipAddressType.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = unicast
ipAddressType.ipv6."fe:80:00:00:00:00:00:00:5a:8a:5a:ff:fe:f8:fc:0c" = unicast
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAddressPrefix]

CMD EXITCODE[0]
CMD RUNTIME[0.0125s]
STDOUT[
ipAddressPrefix.ipv4."127.0.0.1" = ipAddressPrefixOrigin.1.ipv4."127.0.0.0".8
ipAddressPrefix.ipv4."192.168.138.133" = ipAddressPrefixOrigin.9.ipv4."192.168.138.0".23
ipAddressPrefix.ipv4."192.168.139.255" = ipAddressPrefixOrigin.9.ipv4."192.168.138.0".23
ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128
ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:5a:8a:5a:ff:fe:f8:fc:0c" = ipAddressPrefixOrigin.9.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipAddressOrigin]

CMD EXITCODE[0]
CMD RUNTIME[0.0129s]
STDOUT[
ipAddressOrigin.ipv4."127.0.0.1" = manual
ipAddressOrigin.ipv4."192.168.138.133" = manual
ipAddressOrigin.ipv4."192.168.139.255" = manual
ipAddressOrigin.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = manual
ipAddressOrigin.ipv6."fe:80:00:00:00:00:00:00:5a:8a:5a:ff:fe:f8:fc:0c" = linklayer
]
SNMP STATUS[TRUE]
Added 0000:0000:0000:0000:0000:0000:0000:0001
.Address fe80:0000:0000:0000:5a8a:5aff:fef8:fc0c/64 marked as invalid by type [link-local].
Address 'fe80:0000:0000:0000:5a8a:5aff:fef8:fc0c/64' skipped as invalid.

 o IPV6-MIB             

SQL[SELECT * FROM `ipv4_addresses`
            WHERE `device_id` = '429']
SQL RUNTIME[0.00029397s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '429' AND `ifIndex` = '1' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00013685s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '4382331']
SQL RUNTIME[0.00019503s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '4382331']
SQL RUNTIME[0.00015593s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '429']
SQL RUNTIME[0.00016594s]

SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '429']
SQL RUNTIME[0.00015688s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
SQL RUNTIME[0.00011420s]

SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '429' AND `ifIndex` = '9' AND `deleted` = '0' LIMIT 1]
SQL RUNTIME[0.00011587s]

SQL[SELECT * FROM `ports`  WHERE `ports`.`port_id` = '4382332']
SQL RUNTIME[0.00016212s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'port' AND `entity_id` = '4382332']
SQL RUNTIME[0.00016809s]

SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.138.0/23']
SQL RUNTIME[0.00012589s]

SQL[SELECT * FROM `ipv4_addresses`
            WHERE `device_id` = '429']
SQL RUNTIME[0.00014400s]

SQL[SELECT * FROM `ipv6_addresses`
            WHERE `device_id` = '429']
SQL RUNTIME[0.00013185s]

SQL[SELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = '0:0:0:0:0:0:0:1/128']
SQL RUNTIME[0.00009704s]

SQL[SELECT * FROM `ipv6_addresses`
            WHERE `device_id` = '429']
SQL RUNTIME[0.00012779s]
+---------+---------+-------------+--------------------+---------------------+----------+--------+
| ifIndex | ifDescr | IP: Version | Address            | Network             | Type     | Origin |
+---------+---------+-------------+--------------------+---------------------+----------+--------+
| 1       | lo      | IPv4        | 127.0.0.1/8        | 127.0.0.0/8         | loopback |        |
| 9       | bond0   | IPv4        | 192.168.138.133/23 | 192.168.138.0/23    | unicast  |        |
| 1       | lo      | IPv6        | ::1/128            | 0:0:0:0:0:0:0:1/128 | loopback | manual |
+---------+---------+-------------+--------------------+---------------------+----------+--------+


 o Changes              3 unchanged
 o Duration             0.1105s

#####  Module Start: processors  #####

 o UCD-SNMP-MIB         
SQL[SELECT EXISTS (SELECT 1 FROM `processors` WHERE `device_id` = '429' AND `processor_type` != 'ucd-old')]
SQL RUNTIME[0.00015402s]

CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUv -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ssCpuIdle.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0107s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' hrDevice]

CMD EXITCODE[0]
CMD RUNTIME[0.0128s]
STDOUT[
hrDevice = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' hrProcessorLoad]

CMD EXITCODE[0]
CMD RUNTIME[0.0127s]
STDOUT[
hrProcessorLoad = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `processors` WHERE `device_id` = '429']
SQL RUNTIME[0.00027514s]

 o Duration             0.041s

#####  Module Start: mempools  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' memTotalReal.0 memAvailReal.0 memBuffer.0 memCached.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0096s]
STDOUT[
memTotalReal.0 = No Such Object available on this agent at this OID
memAvailReal.0 = No Such Object available on this agent at this OID
memBuffer.0 = No Such Object available on this agent at this OID
memCached.0 = No Such Object available on this agent at this OID
]
SNMP ERROR[#1000 - Failed response]
SNMP STATUS[FALSE]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' hrStorageEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0124s]
STDOUT[
hrStorageEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `mempools` WHERE `device_id` = '429']
SQL RUNTIME[0.00030708s]

 o Duration             0.0258s

#####  Module Start: inventory  #####

 o DELL-RAC-MIB         
CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUv -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsProductType.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0162s]
STDOUT[
0
]
SNMP STATUS[TRUE]

 o ENTITY-MIB           ENTITY-MIB 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'rac-vm03.fqdn.local':'161' entPhysicalEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0477s]
STDOUT[
entPhysicalEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' hrDeviceEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0147s]
STDOUT[
hrDeviceEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' hrProcessorEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0135s]
STDOUT[
hrProcessorEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `hrDevice` WHERE `device_id`  = '429']
SQL RUNTIME[0.00027609s]


 o Duration             0.0982s

#####  Module Start: printersupplies  #####


SQL[SELECT * FROM `printersupplies` WHERE `device_id` = '429']
SQL RUNTIME[0.00015116s]


 o Duration             0.0005s

#####  Module Start: sensors  #####

 o IDRAC-MIB-SMIv2      temperatureProbeReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeReading]

CMD EXITCODE[0]
CMD RUNTIME[0.0236s]
STDOUT[
temperatureProbeReading.1.1 = 610
temperatureProbeReading.1.2 = 610
temperatureProbeReading.1.3 = 240
temperatureProbeReading.1.4 = 410
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0253s]
STDOUT[
temperatureProbeLocationName.1.1 = "CPU1 Temp"
temperatureProbeLocationName.1.2 = "CPU2 Temp"
temperatureProbeLocationName.1.3 = "System Board Inlet Temp"
temperatureProbeLocationName.1.4 = "System Board Exhaust Temp"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLocationName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0287s]
STDOUT[
temperatureProbeLowerCriticalThreshold.1.1 = 30
temperatureProbeLowerCriticalThreshold.1.2 = 30
temperatureProbeLowerCriticalThreshold.1.3 = -70
temperatureProbeLowerCriticalThreshold.1.4 = 30
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLowerCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeLowerNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0261s]
STDOUT[
temperatureProbeLowerNonCriticalThreshold.1.3 = 30
temperatureProbeLowerNonCriticalThreshold.1.4 = 80
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeLowerNonCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeUpperNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0645s]
STDOUT[
temperatureProbeUpperNonCriticalThreshold.1.3 = 380
temperatureProbeUpperNonCriticalThreshold.1.4 = 750
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeUpperNonCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0256s]
STDOUT[
temperatureProbeUpperCriticalThreshold.1.1 = 1000
temperatureProbeUpperCriticalThreshold.1.2 = 1000
temperatureProbeUpperCriticalThreshold.1.3 = 420
temperatureProbeUpperCriticalThreshold.1.4 = 800
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeUpperCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' temperatureProbeStateSettings]

CMD EXITCODE[0]
CMD RUNTIME[0.0288s]
STDOUT[
temperatureProbeStateSettings.1.1 = enabled
temperatureProbeStateSettings.1.2 = enabled
temperatureProbeStateSettings.1.3 = enabled
temperatureProbeStateSettings.1.4 = enabled
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::temperatureProbeStateSettings
  String 'CPU1 Temp' transformed by action [replace] to: 'CPU1 '
Discover sensor: [class: temperature, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: CPU1 , scale: 0.1, limits: (3, , , 100), CURRENT: 61, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.1')]
SQL RUNTIME[0.00042105s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.1']
SQL RUNTIME[0.00026298s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9600' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012994s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-temperature-temperatureProbeReading-1.1.rrd'
  String 'CPU2 Temp' transformed by action [replace] to: 'CPU2 '
Discover sensor: [class: temperature, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: CPU2 , scale: 0.1, limits: (3, , , 100), CURRENT: 61, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.2')]
SQL RUNTIME[0.00020599s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.2']
SQL RUNTIME[0.00021601s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9601' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011778s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-temperature-temperatureProbeReading-1.2.rrd'
  String 'System Board Inlet Temp' transformed by action [replace] to: 'System Board Inlet '
Discover sensor: [class: temperature, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: System Board Inlet , scale: 0.1, limits: (-7, 3, 38, 42), CURRENT: 24, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.3')]
SQL RUNTIME[0.00019789s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.3']
SQL RUNTIME[0.00020909s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9602' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012279s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-temperature-temperatureProbeReading-1.3.rrd'
  String 'System Board Exhaust Temp' transformed by action [replace] to: 'System Board Exhaust '
Discover sensor: [class: temperature, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.4, index: 1.4, type: IDRAC-MIB-SMIv2-temperatureProbeReading, descr: System Board Exhaust , scale: 0.1, limits: (3, 8, 75, 80), CURRENT: 41, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.4')]
SQL RUNTIME[0.00020003s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-temperatureProbeReading' AND `sensor_index` = '1.4']
SQL RUNTIME[0.00020909s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9603' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011516s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-temperature-temperatureProbeReading-1.4.rrd'
] coolingDeviceReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceReading]

CMD EXITCODE[0]
CMD RUNTIME[0.042s]
STDOUT[
coolingDeviceReading.1.1 = 6600
coolingDeviceReading.1.2 = 6960
coolingDeviceReading.1.3 = 6720
coolingDeviceReading.1.4 = 6480
coolingDeviceReading.1.5 = 7320
coolingDeviceReading.1.6 = 6600
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0251s]
STDOUT[
coolingDeviceLocationName.1.1 = "System Board Fan1"
coolingDeviceLocationName.1.2 = "System Board Fan2"
coolingDeviceLocationName.1.3 = "System Board Fan3"
coolingDeviceLocationName.1.4 = "System Board Fan4"
coolingDeviceLocationName.1.5 = "System Board Fan5"
coolingDeviceLocationName.1.6 = "System Board Fan6"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLocationName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0275s]
STDOUT[
coolingDeviceLowerCriticalThreshold.1.1 = 480
coolingDeviceLowerCriticalThreshold.1.2 = 480
coolingDeviceLowerCriticalThreshold.1.3 = 480
coolingDeviceLowerCriticalThreshold.1.4 = 480
coolingDeviceLowerCriticalThreshold.1.5 = 480
coolingDeviceLowerCriticalThreshold.1.6 = 480
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLowerCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceLowerNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0228s]
STDOUT[
coolingDeviceLowerNonCriticalThreshold.1.1 = 840
coolingDeviceLowerNonCriticalThreshold.1.2 = 840
coolingDeviceLowerNonCriticalThreshold.1.3 = 840
coolingDeviceLowerNonCriticalThreshold.1.4 = 840
coolingDeviceLowerNonCriticalThreshold.1.5 = 840
coolingDeviceLowerNonCriticalThreshold.1.6 = 840
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceLowerNonCriticalThreshold

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceUpperNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0249s]
STDOUT[
coolingDeviceUpperNonCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0274s]
STDOUT[
coolingDeviceUpperCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' coolingDeviceStateSettings]

CMD EXITCODE[0]
CMD RUNTIME[0.0242s]
STDOUT[
coolingDeviceStateSettings.1.1 = enabled
coolingDeviceStateSettings.1.2 = enabled
coolingDeviceStateSettings.1.3 = enabled
coolingDeviceStateSettings.1.4 = enabled
coolingDeviceStateSettings.1.5 = enabled
coolingDeviceStateSettings.1.6 = enabled
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::coolingDeviceStateSettings
  String 'System Board Fan1' transformed by action [replace] to: 'System Board Fan1'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan1, scale: 1, limits: (480, 840, , ), CURRENT: 6600, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.1')]
SQL RUNTIME[0.00043106s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.1']
SQL RUNTIME[0.00027394s]
LCurrent sensor value: "6600", scale: "1"
  limit_high: "11448" -> "11880"
  limit_high_warn: "" -> ""
  limit_low: "480" -> "480"
  limit_low_warn: "840" -> "840"


SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`)  VALUES ('429','9594','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"11880\"')]
SQL RUNTIME[0.00149488s]

SQL[UPDATE `sensors` SET `sensor_limit` ='11880' WHERE `sensor_id` = '9594']
SQL RUNTIME[0.00135207s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9594' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00018287s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.1.rrd'
  String 'System Board Fan2' transformed by action [replace] to: 'System Board Fan2'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan2, scale: 1, limits: (480, 840, , ), CURRENT: 6960, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.2')]
SQL RUNTIME[0.00022888s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.2']
SQL RUNTIME[0.00024390s]
LCurrent sensor value: "6960", scale: "1"
  limit_high: "11232" -> "12528"
  limit_high_warn: "" -> ""
  limit_low: "480" -> "480"
  limit_low_warn: "840" -> "840"


SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`)  VALUES ('429','9595','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"12528\"')]
SQL RUNTIME[0.00114703s]

SQL[UPDATE `sensors` SET `sensor_limit` ='12528' WHERE `sensor_id` = '9595']
SQL RUNTIME[0.00112391s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9595' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013089s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.2.rrd'
  String 'System Board Fan3' transformed by action [replace] to: 'System Board Fan3'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan3, scale: 1, limits: (480, 840, , ), CURRENT: 6720, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.3')]
SQL RUNTIME[0.00020790s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.3']
SQL RUNTIME[0.00023198s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9596' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012302s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.3.rrd'
  String 'System Board Fan4' transformed by action [replace] to: 'System Board Fan4'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.4, index: 1.4, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan4, scale: 1, limits: (480, 840, , ), CURRENT: 6480, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.4')]
SQL RUNTIME[0.00021100s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.4']
SQL RUNTIME[0.00022602s]
LCurrent sensor value: "6480", scale: "1"
  limit_high: "12096" -> "11664"
  limit_high_warn: "" -> ""
  limit_low: "480" -> "480"
  limit_low_warn: "840" -> "840"


SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`)  VALUES ('429','9597','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"11664\"')]
SQL RUNTIME[0.00143909s]

SQL[UPDATE `sensors` SET `sensor_limit` ='11664' WHERE `sensor_id` = '9597']
SQL RUNTIME[0.00109506s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9597' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012994s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.4.rrd'
  String 'System Board Fan5' transformed by action [replace] to: 'System Board Fan5'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.5, index: 1.5, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan5, scale: 1, limits: (480, 840, , ), CURRENT: 7320, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.5')]
SQL RUNTIME[0.00021100s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.5']
SQL RUNTIME[0.00021601s]
LCurrent sensor value: "7320", scale: "1"
  limit_high: "12312" -> "13176"
  limit_high_warn: "" -> ""
  limit_low: "480" -> "480"
  limit_low_warn: "840" -> "840"


SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`)  VALUES ('429','9598','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"13176\"')]
SQL RUNTIME[0.00109410s]

SQL[UPDATE `sensors` SET `sensor_limit` ='13176' WHERE `sensor_id` = '9598']
SQL RUNTIME[0.00108290s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9598' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00017285s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.5.rrd'
  String 'System Board Fan6' transformed by action [replace] to: 'System Board Fan6'
Discover sensor: [class: fanspeed, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.6, index: 1.6, type: IDRAC-MIB-SMIv2-coolingDeviceReading, descr: System Board Fan6, scale: 1, limits: (480, 840, , ), CURRENT: 6600, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.6')]
SQL RUNTIME[0.00030208s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-coolingDeviceReading' AND `sensor_index` = '1.6']
SQL RUNTIME[0.00034308s]
LCurrent sensor value: "6600", scale: "1"
  limit_high: "12528" -> "11880"
  limit_high_warn: "" -> ""
  limit_low: "480" -> "480"
  limit_low_warn: "840" -> "840"


SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`)  VALUES ('429','9599','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"11880\"')]
SQL RUNTIME[0.00118184s]

SQL[UPDATE `sensors` SET `sensor_limit` ='11880' WHERE `sensor_id` = '9599']
SQL RUNTIME[0.00116515s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9599' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00017381s]
.RRD old file not found: '/opt/observium/rrd/rac-vm03.fqdn.local/sensor-fanspeed-coolingDeviceReading-1.6.rrd'
] voltageProbeReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeReading]

CMD EXITCODE[0]
CMD RUNTIME[0.0276s]
STDOUT[
voltageProbeReading.1.33 = 226000
voltageProbeReading.1.34 = 228000
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0861s]
STDOUT[
voltageProbeLocationName.1.1 = "System Board DIMM PG"
voltageProbeLocationName.1.2 = "System Board NDC PG"
voltageProbeLocationName.1.3 = "System Board PS1 PG FAIL"
voltageProbeLocationName.1.4 = "System Board PS2 PG FAIL"
voltageProbeLocationName.1.5 = "System Board BP0 PG"
voltageProbeLocationName.1.6 = "System Board BP1 PG"
voltageProbeLocationName.1.7 = "System Board BP2 PG"
voltageProbeLocationName.1.8 = "System Board 1.8V SW PG"
voltageProbeLocationName.1.9 = "System Board 2.5V SW PG"
voltageProbeLocationName.1.10 = "System Board 5V SW PG"
voltageProbeLocationName.1.11 = "System Board PVNN SW PG"
voltageProbeLocationName.1.12 = "System Board VSB11 SW PG"
voltageProbeLocationName.1.13 = "System Board VSBM SW PG"
voltageProbeLocationName.1.14 = "System Board 3.3V B PG"
voltageProbeLocationName.1.15 = "CPU1 MEM012 VDDQ PG"
voltageProbeLocationName.1.16 = "CPU1 MEM012 VPP PG"
voltageProbeLocationName.1.17 = "CPU1 MEM012 VTT PG"
voltageProbeLocationName.1.18 = "CPU1 MEM345 VDDQ PG"
voltageProbeLocationName.1.19 = "CPU1 MEM345 VPP PG"
voltageProbeLocationName.1.20 = "CPU1 MEM345 VTT PG"
voltageProbeLocationName.1.21 = "CPU1 VCCIO PG"
voltageProbeLocationName.1.22 = "CPU1 VCORE PG"
voltageProbeLocationName.1.23 = "CPU1 FIVR PG"
voltageProbeLocationName.1.24 = "CPU2 MEM012 VDDQ PG"
voltageProbeLocationName.1.25 = "CPU2 MEM012 VPP PG"
voltageProbeLocationName.1.26 = "CPU2 MEM012 VTT PG"
voltageProbeLocationName.1.27 = "CPU2 MEM345 VDDQ PG"
voltageProbeLocationName.1.28 = "CPU2 MEM345 VPP PG"
voltageProbeLocationName.1.29 = "CPU2 MEM345 VTT PG"
voltageProbeLocationName.1.30 = "CPU2 VCCIO PG"
voltageProbeLocationName.1.31 = "CPU2 VCORE PG"
voltageProbeLocationName.1.32 = "CPU2 FIVR PG"
voltageProbeLocationName.1.33 = "PS1 Voltage 1"
voltageProbeLocationName.1.34 = "PS2 Voltage 2"
voltageProbeLocationName.1.35 = "CPU1 VSA PG"
voltageProbeLocationName.1.36 = "CPU2 VSA PG"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeLocationName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeLowerCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0582s]
STDOUT[
voltageProbeLowerCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeLowerNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0751s]
STDOUT[
voltageProbeLowerNonCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeUpperNonCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0617s]
STDOUT[
voltageProbeUpperNonCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeUpperCriticalThreshold]

CMD EXITCODE[0]
CMD RUNTIME[0.0514s]
STDOUT[
voltageProbeUpperCriticalThreshold = No Such Instance currently exists at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeStateSettings]

CMD EXITCODE[0]
CMD RUNTIME[0.046s]
STDOUT[
voltageProbeStateSettings.1.1 = enabled
voltageProbeStateSettings.1.2 = enabled
voltageProbeStateSettings.1.3 = enabled
voltageProbeStateSettings.1.4 = enabled
voltageProbeStateSettings.1.5 = enabled
voltageProbeStateSettings.1.6 = enabled
voltageProbeStateSettings.1.7 = enabled
voltageProbeStateSettings.1.8 = enabled
voltageProbeStateSettings.1.9 = enabled
voltageProbeStateSettings.1.10 = enabled
voltageProbeStateSettings.1.11 = enabled
voltageProbeStateSettings.1.12 = enabled
voltageProbeStateSettings.1.13 = enabled
voltageProbeStateSettings.1.14 = enabled
voltageProbeStateSettings.1.15 = enabled
voltageProbeStateSettings.1.16 = enabled
voltageProbeStateSettings.1.17 = enabled
voltageProbeStateSettings.1.18 = enabled
voltageProbeStateSettings.1.19 = enabled
voltageProbeStateSettings.1.20 = enabled
voltageProbeStateSettings.1.21 = enabled
voltageProbeStateSettings.1.22 = enabled
voltageProbeStateSettings.1.23 = enabled
voltageProbeStateSettings.1.24 = enabled
voltageProbeStateSettings.1.25 = enabled
voltageProbeStateSettings.1.26 = enabled
voltageProbeStateSettings.1.27 = enabled
voltageProbeStateSettings.1.28 = enabled
voltageProbeStateSettings.1.29 = enabled
voltageProbeStateSettings.1.30 = enabled
voltageProbeStateSettings.1.31 = enabled
voltageProbeStateSettings.1.32 = enabled
voltageProbeStateSettings.1.33 = enabled
voltageProbeStateSettings.1.34 = enabled
voltageProbeStateSettings.1.35 = enabled
voltageProbeStateSettings.1.36 = enabled
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeStateSettings
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
  String 'PS1 Voltage 1' transformed by action [replace] to: 'Power supply 1'
Discover sensor: [class: voltage, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.33, index: 1.33, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: Power supply 1, scale: 0.001, limits: (, , , ), CURRENT: 226, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.33')]
SQL RUNTIME[0.00042892s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.33']
SQL RUNTIME[0.00024915s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9592' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013018s]
.  String 'PS2 Voltage 2' transformed by action [replace] to: 'Power supply 2'
Discover sensor: [class: voltage, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.6.1.34, index: 1.34, type: IDRAC-MIB-SMIv2-voltageProbeReading, descr: Power supply 2, scale: 0.001, limits: (, , , ), CURRENT: 228, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.34')]
SQL RUNTIME[0.00021410s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-voltageProbeReading' AND `sensor_index` = '1.34']
SQL RUNTIME[0.00020909s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9593' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011897s]
.Excluded by current value () is not numeric.
Excluded by current value () is not numeric.
] amperageProbeReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' amperageProbeTable]

CMD EXITCODE[0]
CMD RUNTIME[0.0442s]
STDOUT[
amperageProbechassisIndex.1.1 = 1
amperageProbechassisIndex.1.2 = 1
amperageProbechassisIndex.1.3 = 1
amperageProbeIndex.1.1 = 1
amperageProbeIndex.1.2 = 2
amperageProbeIndex.1.3 = 3
amperageProbeStateCapabilities.1.1 = 0
amperageProbeStateCapabilities.1.2 = 0
amperageProbeStateCapabilities.1.3 = 0
amperageProbeStateSettings.1.1 = enabled
amperageProbeStateSettings.1.2 = enabled
amperageProbeStateSettings.1.3 = enabled
amperageProbeStatus.1.1 = ok
amperageProbeStatus.1.2 = ok
amperageProbeStatus.1.3 = ok
amperageProbeReading.1.1 = 12
amperageProbeReading.1.2 = 10
amperageProbeReading.1.3 = 468
amperageProbeType.1.1 = amperageProbeTypeIsPowerSupplyAmps
amperageProbeType.1.2 = amperageProbeTypeIsPowerSupplyAmps
amperageProbeType.1.3 = amperageProbeTypeIsSystemWatts
amperageProbeLocationName.1.1 = "PS1 Current 1"
amperageProbeLocationName.1.2 = "PS2 Current 2"
amperageProbeLocationName.1.3 = "System Board Pwr Consumption"
amperageProbeUpperCriticalThreshold.1.3 = 1300
amperageProbeUpperNonCriticalThreshold.1.3 = 1170
amperageProbeProbeCapabilities.1.1 = 0
amperageProbeProbeCapabilities.1.2 = 0
amperageProbeProbeCapabilities.1.3 = 5
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::amperageProbeTable
Scale mapped from value [amperageProbeTypeIsPowerSupplyAmps] to 0.1
  String 'PS1 Current 1' transformed by action [replace] to: 'Power supply 1'
Discover sensor: [class: current, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.1, index: 1.1, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: Power supply 1, scale: 0.1, limits: (, , , ), CURRENT: 1.2, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.1')]
SQL RUNTIME[0.00041103s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.1']
SQL RUNTIME[0.00026202s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9604' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00012302s]
.Scale mapped from value [amperageProbeTypeIsPowerSupplyAmps] to 0.1
  String 'PS2 Current 2' transformed by action [replace] to: 'Power supply 2'
Discover sensor: [class: current, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.2, index: 1.2, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: Power supply 2, scale: 0.1, limits: (, , , ), CURRENT: 1, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.2')]
SQL RUNTIME[0.00019383s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.2']
SQL RUNTIME[0.00026393s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9605' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00011897s]
.Scale mapped from value [amperageProbeTypeIsSystemWatts] to 1
  String 'System Board Pwr Consumption' transformed by action [replace] to: 'System Board'
Discover sensor: [class: power, device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.30.1.6.1.3, index: 1.3, type: IDRAC-MIB-SMIv2-amperageProbeReading, descr: System Board, scale: 1, limits: (, , 1170, 1300), CURRENT: 468, , 

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.3')]
SQL RUNTIME[0.00022101s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '429' AND `sensor_type` = 'IDRAC-MIB-SMIv2-amperageProbeReading' AND `sensor_index` = '1.3']
SQL RUNTIME[0.00027514s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9606' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00013399s]
.] 
 o IDRAC-MIB-SMIv2      globalSystemStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' globalSystemStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0393s]
STDOUT[
globalSystemStatus.0 = ok
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::globalSystemStatus
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.2.1.0, index: 0, type: ObjectStatusEnum, descr: Overall System Status, CURRENT: 3, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalSystemStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00050688s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalSystemStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00033188s]
.] systemLCDStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' systemLCDStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0374s]
STDOUT[
systemLCDStatus.0 = ok
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::systemLCDStatus
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.2.2.0, index: 0, type: ObjectStatusEnum, descr: System LCD Status, CURRENT: 3, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLCDStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00039697s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLCDStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00024819s]
.] globalStorageStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' globalStorageStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0248s]
STDOUT[
globalStorageStatus.0 = ok
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::globalStorageStatus
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.2.3.0, index: 0, type: ObjectStatusEnum, descr: Global Storage Status, CURRENT: 3, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalStorageStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00037694s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'globalStorageStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00022101s]
.] systemPowerState [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' systemPowerState]

CMD EXITCODE[0]
CMD RUNTIME[0.0231s]
STDOUT[
systemPowerState.0 = on
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::systemPowerState
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.2.4.0, index: 0, type: PowerStateStatusEnum, descr: System Power State, CURRENT: 4, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemPowerState' AND `status_type` = 'PowerStateStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00035191s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemPowerState' AND `status_type` = 'PowerStateStatusEnum' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00019097s]
.] systemLockdownMode [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' systemLockdownMode]

CMD EXITCODE[0]
CMD RUNTIME[0.0375s]
STDOUT[
systemLockdownMode.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::systemLockdownMode
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.1.3.20.0, index: 0, type: SystemLockdownModeEnum, descr: System Lockdown State, CURRENT: 0, , device]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLockdownMode' AND `status_type` = 'SystemLockdownModeEnum' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00038505s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemLockdownMode' AND `status_type` = 'SystemLockdownModeEnum' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026107s]
.] voltageProbeDiscreteReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeDiscreteReading]

CMD EXITCODE[0]
CMD RUNTIME[0.0428s]
STDOUT[
voltageProbeDiscreteReading.1.1 = voltageIsGood
voltageProbeDiscreteReading.1.2 = voltageIsGood
voltageProbeDiscreteReading.1.3 = voltageIsGood
voltageProbeDiscreteReading.1.4 = voltageIsGood
voltageProbeDiscreteReading.1.5 = voltageIsGood
voltageProbeDiscreteReading.1.6 = voltageIsGood
voltageProbeDiscreteReading.1.7 = voltageIsGood
voltageProbeDiscreteReading.1.8 = voltageIsGood
voltageProbeDiscreteReading.1.9 = voltageIsGood
voltageProbeDiscreteReading.1.10 = voltageIsGood
voltageProbeDiscreteReading.1.11 = voltageIsGood
voltageProbeDiscreteReading.1.12 = voltageIsGood
voltageProbeDiscreteReading.1.13 = voltageIsGood
voltageProbeDiscreteReading.1.14 = voltageIsGood
voltageProbeDiscreteReading.1.15 = voltageIsGood
voltageProbeDiscreteReading.1.16 = voltageIsGood
voltageProbeDiscreteReading.1.17 = voltageIsGood
voltageProbeDiscreteReading.1.18 = voltageIsGood
voltageProbeDiscreteReading.1.19 = voltageIsGood
voltageProbeDiscreteReading.1.20 = voltageIsGood
voltageProbeDiscreteReading.1.21 = voltageIsGood
voltageProbeDiscreteReading.1.22 = voltageIsGood
voltageProbeDiscreteReading.1.23 = voltageIsGood
voltageProbeDiscreteReading.1.24 = voltageIsGood
voltageProbeDiscreteReading.1.25 = voltageIsGood
voltageProbeDiscreteReading.1.26 = voltageIsGood
voltageProbeDiscreteReading.1.27 = voltageIsGood
voltageProbeDiscreteReading.1.28 = voltageIsGood
voltageProbeDiscreteReading.1.29 = voltageIsGood
voltageProbeDiscreteReading.1.30 = voltageIsGood
voltageProbeDiscreteReading.1.31 = voltageIsGood
voltageProbeDiscreteReading.1.32 = voltageIsGood
voltageProbeDiscreteReading.1.35 = voltageIsGood
voltageProbeDiscreteReading.1.36 = voltageIsGood
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeDiscreteReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' voltageProbeType]

CMD EXITCODE[0]
CMD RUNTIME[0.0435s]
STDOUT[
voltageProbeType.1.1 = voltageProbeTypeIsDiscrete
voltageProbeType.1.2 = voltageProbeTypeIsDiscrete
voltageProbeType.1.3 = voltageProbeTypeIsDiscrete
voltageProbeType.1.4 = voltageProbeTypeIsDiscrete
voltageProbeType.1.5 = voltageProbeTypeIsDiscrete
voltageProbeType.1.6 = voltageProbeTypeIsDiscrete
voltageProbeType.1.7 = voltageProbeTypeIsDiscrete
voltageProbeType.1.8 = voltageProbeTypeIsDiscrete
voltageProbeType.1.9 = voltageProbeTypeIsDiscrete
voltageProbeType.1.10 = voltageProbeTypeIsDiscrete
voltageProbeType.1.11 = voltageProbeTypeIsDiscrete
voltageProbeType.1.12 = voltageProbeTypeIsDiscrete
voltageProbeType.1.13 = voltageProbeTypeIsDiscrete
voltageProbeType.1.14 = voltageProbeTypeIsDiscrete
voltageProbeType.1.15 = voltageProbeTypeIsDiscrete
voltageProbeType.1.16 = voltageProbeTypeIsDiscrete
voltageProbeType.1.17 = voltageProbeTypeIsDiscrete
voltageProbeType.1.18 = voltageProbeTypeIsDiscrete
voltageProbeType.1.19 = voltageProbeTypeIsDiscrete
voltageProbeType.1.20 = voltageProbeTypeIsDiscrete
voltageProbeType.1.21 = voltageProbeTypeIsDiscrete
voltageProbeType.1.22 = voltageProbeTypeIsDiscrete
voltageProbeType.1.23 = voltageProbeTypeIsDiscrete
voltageProbeType.1.24 = voltageProbeTypeIsDiscrete
voltageProbeType.1.25 = voltageProbeTypeIsDiscrete
voltageProbeType.1.26 = voltageProbeTypeIsDiscrete
voltageProbeType.1.27 = voltageProbeTypeIsDiscrete
voltageProbeType.1.28 = voltageProbeTypeIsDiscrete
voltageProbeType.1.29 = voltageProbeTypeIsDiscrete
voltageProbeType.1.30 = voltageProbeTypeIsDiscrete
voltageProbeType.1.31 = voltageProbeTypeIsDiscrete
voltageProbeType.1.32 = voltageProbeTypeIsDiscrete
voltageProbeType.1.33 = voltageProbeTypeIsPSVoltage
voltageProbeType.1.34 = voltageProbeTypeIsPSVoltage
voltageProbeType.1.35 = voltageProbeTypeIsDiscrete
voltageProbeType.1.36 = voltageProbeTypeIsDiscrete
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::voltageProbeType
Get cached Table OID: IDRAC-MIB-SMIv2::voltageProbeLocationName
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.1, index: 1.1, type: DellVoltageDiscreteReading, descr: Voltage System Board DIMM PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00043511s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00031090s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.2, index: 1.2, type: DellVoltageDiscreteReading, descr: Voltage System Board NDC PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022101s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026608s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.3, index: 1.3, type: DellVoltageDiscreteReading, descr: Voltage System Board PS1 PG FAIL, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.3' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00023389s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.3' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026822s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.4, index: 1.4, type: DellVoltageDiscreteReading, descr: Voltage System Board PS2 PG FAIL, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.4' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00021315s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.4' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026798s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.5, index: 1.5, type: DellVoltageDiscreteReading, descr: Voltage System Board BP0 PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.5' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00020909s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.5' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025892s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.6, index: 1.6, type: DellVoltageDiscreteReading, descr: Voltage System Board BP1 PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.6' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00020981s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.6' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026107s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.7, index: 1.7, type: DellVoltageDiscreteReading, descr: Voltage System Board BP2 PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.7' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022101s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.7' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025892s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.8, index: 1.8, type: DellVoltageDiscreteReading, descr: Voltage System Board 1.8V SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.8' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00021720s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.8' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026488s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.9, index: 1.9, type: DellVoltageDiscreteReading, descr: Voltage System Board 2.5V SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.9' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022006s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.9' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025988s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.10, index: 1.10, type: DellVoltageDiscreteReading, descr: Voltage System Board 5V SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.10' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00021815s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.10' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026798s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.11, index: 1.11, type: DellVoltageDiscreteReading, descr: Voltage System Board PVNN SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.11' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022292s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.11' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025702s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.12, index: 1.12, type: DellVoltageDiscreteReading, descr: Voltage System Board VSB11 SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.12' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022697s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.12' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00027704s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.13, index: 1.13, type: DellVoltageDiscreteReading, descr: Voltage System Board VSBM SW PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.13' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022221s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.13' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026393s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.14, index: 1.14, type: DellVoltageDiscreteReading, descr: Voltage System Board 3.3V B PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.14' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00022602s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.14' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025606s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.15, index: 1.15, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM012 VDDQ PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.15' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025797s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.15' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026107s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.16, index: 1.16, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM012 VPP PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.16' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00023007s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.16' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00031281s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.17, index: 1.17, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM012 VTT PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.17' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00023699s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.17' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025702s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.18, index: 1.18, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM345 VDDQ PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.18' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025988s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.18' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00033498s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.19, index: 1.19, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM345 VPP PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.19' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00024796s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.19' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00027704s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.20, index: 1.20, type: DellVoltageDiscreteReading, descr: Voltage CPU1 MEM345 VTT PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.20' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00024104s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.20' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025797s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.21, index: 1.21, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VCCIO PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.21' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00027204s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.21' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00029111s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.22, index: 1.22, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VCORE PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.22' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00024605s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.22' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026703s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.23, index: 1.23, type: DellVoltageDiscreteReading, descr: Voltage CPU1 FIVR PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.23' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00024199s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.23' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026894s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.24, index: 1.24, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM012 VDDQ PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.24' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00024199s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.24' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026298s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.25, index: 1.25, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM012 VPP PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.25' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026894s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.25' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026393s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.26, index: 1.26, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM012 VTT PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.26' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025010s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.26' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00029492s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.27, index: 1.27, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM345 VDDQ PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.27' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026202s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.27' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025892s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.28, index: 1.28, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM345 VPP PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.28' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026107s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.28' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026703s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.29, index: 1.29, type: DellVoltageDiscreteReading, descr: Voltage CPU2 MEM345 VTT PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.29' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00031686s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.29' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00027013s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.30, index: 1.30, type: DellVoltageDiscreteReading, descr: Voltage CPU2 VCCIO PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.30' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025797s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.30' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025702s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.31, index: 1.31, type: DellVoltageDiscreteReading, descr: Voltage CPU2 VCORE PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.31' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025916s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.31' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026298s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.32, index: 1.32, type: DellVoltageDiscreteReading, descr: Voltage CPU2 FIVR PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.32' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00027394s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.32' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026417s]
.Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete]
Excluded by not test condition: voltageProbeType [voltageProbeTypeIsPSVoltage] eq [voltageProbeTypeIsDiscrete]
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.35, index: 1.35, type: DellVoltageDiscreteReading, descr: Voltage CPU1 VSA PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.35' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00025797s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.35' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00026703s]
.Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.20.1.16.1.36, index: 1.36, type: DellVoltageDiscreteReading, descr: Voltage CPU2 VSA PG, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.36' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00026202s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'voltageProbeDiscreteReading' AND `status_type` = 'DellVoltageDiscreteReading' AND `status_index` = '1.36' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00025892s]
.] powerSupplyStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' powerSupplyStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0309s]
STDOUT[
powerSupplyStatus.1.1 = ok
powerSupplyStatus.1.2 = ok
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyStatus

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' powerSupplyLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0301s]
STDOUT[
powerSupplyLocationName.1.1 = "PS1 Status"
powerSupplyLocationName.1.2 = "PS2 Status"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyLocationName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' powerSupplyStateSettingsUnique]

CMD EXITCODE[0]
CMD RUNTIME[0.0243s]
STDOUT[
powerSupplyStateSettingsUnique.1.1 = acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline
powerSupplyStateSettingsUnique.1.2 = acPowerAndSwitchAreOnPowerSupplyIsOnIsOkAndOnline
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::powerSupplyStateSettingsUnique
  String 'PS1 Status' transformed by action [replace] to: 'Power supply 1 Status'
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.12.1.5.1.1, index: 1.1, type: ObjectStatusEnum, descr: Power supply 1 Status, CURRENT: 3, , powersupply]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00039506s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00022101s]
.  String 'PS2 Status' transformed by action [replace] to: 'Power supply 2 Status'
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.12.1.5.1.2, index: 1.2, type: ObjectStatusEnum, descr: Power supply 2 Status, CURRENT: 3, , powersupply]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.2' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00018597s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'powerSupplyStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1.2' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00018597s]
.] chassisStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' chassisStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1057s]
STDOUT[
chassisStatus.1 = ok
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::chassisStatus

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' chassisName]

CMD EXITCODE[0]
CMD RUNTIME[0.1027s]
STDOUT[
chassisName.1 = "Main System Chassis"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::chassisName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' chassisStateSettings]

CMD EXITCODE[0]
CMD RUNTIME[0.0917s]
STDOUT[
chassisStateSettings.1 = enabled
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::chassisStateSettings
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.300.10.1.4.1, index: 1, type: ObjectStatusEnum, descr: Main System Chassis, CURRENT: 3, , chassis]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'chassisStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00042391s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'chassisStatus' AND `status_type` = 'ObjectStatusEnum' AND `status_index` = '1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00022006s]
.] intrusionReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' intrusionReading]

CMD EXITCODE[0]
CMD RUNTIME[0.0249s]
STDOUT[
intrusionReading.1.1 = chassisNotBreached
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' intrusionLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0243s]
STDOUT[
intrusionLocationName.1.1 = "System Board Intrusion"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionLocationName

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' intrusionStateSettings]

CMD EXITCODE[0]
CMD RUNTIME[0.0237s]
STDOUT[
intrusionStateSettings.1.1 = enabled
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::intrusionStateSettings
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.300.70.1.6.1.1, index: 1.1, type: DellIntrusionReading, descr: System Board Intrusion, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'intrusionReading' AND `status_type` = 'DellIntrusionReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00038791s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'intrusionReading' AND `status_type` = 'DellIntrusionReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00020099s]
.] systemBatteryReading [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' systemBatteryReading]

CMD EXITCODE[0]
CMD RUNTIME[0.0258s]
STDOUT[
systemBatteryReading.1.1 = presenceDetected
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::systemBatteryReading

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m IDRAC-MIB-SMIv2 -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' systemBatteryLocationName]

CMD EXITCODE[0]
CMD RUNTIME[0.0355s]
STDOUT[
systemBatteryLocationName.1.1 = "System Board CMOS Battery"
]
SNMP STATUS[TRUE]
Store in cache Table OID: IDRAC-MIB-SMIv2::systemBatteryLocationName
Discover status: [device: rac-vm03.fqdn.local, oid: .1.3.6.1.4.1.674.10892.5.4.600.50.1.6.1.1, index: 1.1, type: DellBatteryReading, descr: System Board CMOS Battery, CURRENT: 4, , battery]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00046396s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `status_mib` = 'IDRAC-MIB-SMIv2' AND `status_object` = 'systemBatteryReading' AND `status_type` = 'DellBatteryReading' AND `status_index` = '1.1' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00022411s]
.] 
 o DELL-RAC-MIB         drsChassisFrontPanelAmbientTemperature [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsChassisFrontPanelAmbientTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.1138s]
STDOUT[
drsChassisFrontPanelAmbientTemperature = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsCMCAmbientTemperature [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsCMCAmbientTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.0849s]
STDOUT[
drsCMCAmbientTemperature = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsCMCProcessorTemperature [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsCMCProcessorTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.0747s]
STDOUT[
drsCMCProcessorTemperature = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] 
 o DELL-RAC-MIB         drsGlobalSystemStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsGlobalSystemStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.075s]
STDOUT[
drsGlobalSystemStatus.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: DELL-RAC-MIB::drsGlobalSystemStatus
Skipped by unknown state value: 0, Overall System Status 
] drsGlobalCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsGlobalCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0841s]
STDOUT[
drsGlobalCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsIOMCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsIOMCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0819s]
STDOUT[
drsIOMCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsKVMCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsKVMCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1444s]
STDOUT[
drsKVMCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsRedCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsRedCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1428s]
STDOUT[
drsRedCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsPowerCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsPowerCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1202s]
STDOUT[
drsPowerCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsFanCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsFanCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0948s]
STDOUT[
drsFanCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsBladeCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsBladeCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0824s]
STDOUT[
drsBladeCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsTempCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsTempCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0966s]
STDOUT[
drsTempCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsCMCCurrStatus [
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -Ih -OQUsb -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsCMCCurrStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.0839s]
STDOUT[
drsCMCCurrStatus = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
] drsServerMonitoringCapable [
CMD[/usr/bin/snmpget -t '10' -v2c -c *** -Pud -OQUv -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsProductType.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0164s]
STDOUT[
0
]
SNMP STATUS[TRUE]
Store in cache OID: DELL-RAC-MIB::drsProductType.0
Excluded by not test condition: DELL-RAC-MIB::drsProductType.0 [0] in [cmc, vrtxCMC, fx2CMC]
!]
 o DELL-RAC-MIB         
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsCMCPowerTable]

CMD EXITCODE[0]
CMD RUNTIME[0.1112s]
STDOUT[
drsCMCPowerTable = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m DELL-RAC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/dell 'udp':'rac-vm03.fqdn.local':'161' drsCMCPSUTable]

CMD EXITCODE[0]
CMD RUNTIME[0.0944s]
STDOUT[
drsCMCPSUTable = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o ENTITY-SENSOR-MIB    
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.0518s]
STDOUT[
entPhySensorValue = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00047517s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027514s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00031996s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00025511s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00019407s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00021696s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00044703s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00034499s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00018883s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014496s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00015211s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00015092s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014210s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013995s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00017381s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029898s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014091s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013900s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013399s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00016379s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00019693s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00017691s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014281s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013685s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013518s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013304s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014091s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00014806s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '429' AND `sensor_class` = 'gauge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00013709s]

SQL[SELECT * FROM `status` WHERE `device_id` = '429' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00027704s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '429' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00016212s]


 o Duration             3.3322s

#####  Module Start: storage  #####

 o UCD-SNMP-MIB         
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' dskEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0137s]
STDOUT[
dskEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o HOST-RESOURCES-MIB   

SQL[SELECT * FROM `storage` WHERE `device_id` = '429']
SQL RUNTIME[0.00025797s]

 o Duration             0.0162s

#####  Module Start: neighbours  #####

 o LLDP-MIB             
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m LLDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' lldpRemChassisIdSubtype]

CMD EXITCODE[0]
CMD RUNTIME[0.0214s]
STDOUT[
lldpRemChassisIdSubtype = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o CISCO-CDP-MIB        
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m CISCO-CDP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'rac-vm03.fqdn.local':'161' cdpCache]

CMD EXITCODE[0]
CMD RUNTIME[0.0647s]
STDOUT[
cdpCache = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o OSPF-MIB             
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m OSPF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ospfNbrRtrId]

CMD EXITCODE[0]
CMD RUNTIME[0.0193s]
STDOUT[
ospfNbrRtrId = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `neighbours` WHERE `device_id` = '429']
SQL RUNTIME[0.00026703s]



 o Duration             0.1112s

#####  Module Start: arp-table  #####


SQL[SELECT `port_id`, `ifIndex` FROM `ports` WHERE `device_id` = '429' GROUP BY `port_id`]
SQL RUNTIME[0.00023007s]

CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OXqs -m IP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' ipNetToPhysicalPhysAddress]

CMD EXITCODE[0]
CMD RUNTIME[0.0139s]
STDOUT[
ipNetToPhysicalPhysAddress[9][ipv4]["192.168.138.1"] 0:50:56:aa:fd:1
ipNetToPhysicalPhysAddress[9][ipv4]["192.168.138.2"] 0:50:56:aa:fd:1
ipNetToPhysicalPhysAddress[9][ipv4]["192.168.138.3"] 0:50:56:aa:6e:2d
]
SNMP STATUS[TRUE]
Used IP-MIB::ipNetToPhysicalPhysAddress

SQL[SELECT mac_id, mac_address, ip_address, ip_version, ifIndex FROM ip_mac LEFT JOIN ports USING(`port_id`) WHERE device_id = '429']
SQL RUNTIME[0.00039911s]
...

 o Duration             0.0165s

#####  Module Start: junose-atm-vp  #####


 o Duration             0.0002s

#####  Module Start: bgp-peers  #####


 o Duration             0.0007s

#####  Module Start: mac-accounting  #####


 o Duration             0.0001s

#####  Module Start: sla  #####

 o DISMAN-PING-MIB      
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m DISMAN-PING-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' pingCtlEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0607s]
STDOUT[
pingCtlEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


SQL[SELECT * FROM `slas` WHERE `device_id` = '429']
SQL RUNTIME[0.00028014s]

 o Duration             0.0628s

Module [lsp] disabled globally by config in process [discovery].
#####  Module Start: pseudowires  #####


SQL[SELECT * FROM `pseudowires` WHERE `device_id` = '429']
SQL RUNTIME[0.00022697s]
 o PW-STD-MIB           
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m PW-STD-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' pwID]

CMD EXITCODE[0]
CMD RUNTIME[0.0142s]
STDOUT[
pwID = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


 o Duration             0.0168s

#####  Module Start: virtual-machines  #####



 o Duration             0.0004s

#####  Module Start: cisco-cbqos  #####


 o Duration             0.0002s

#####  Module Start: ucd-diskio  #####


CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m UCD-DISKIO-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' diskIOEntry]

CMD EXITCODE[0]
CMD RUNTIME[0.0154s]
STDOUT[
diskIOEntry = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `ucd_diskio` WHERE `device_id` = '429']
SQL RUNTIME[0.00027895s]


 o Duration             0.0172s

#####  Module Start: wifi  #####


SQL[SELECT * FROM `wifi_radios` WHERE `device_id` = '429']
SQL RUNTIME[0.00015783s]

SQL[SELECT * FROM `wifi_wlans` WHERE `device_id` = '429']
SQL RUNTIME[0.00012398s]

SQL[SELECT * FROM `wifi_aps` WHERE `device_id` = '429']
SQL RUNTIME[0.00011992s]


 o Duration             0.001s

#####  Module Start: p2p-radios  #####


 o Duration             0.0001s

#####  Module Start: graphs  #####


 o Duration             0.0002s

Module [raid] disabled globally by config in process [discovery].
#####  Module Start: cisco-cef  #####

Cisco CEF Switching Path: 
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m CISCO-CEF-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/cisco 'udp':'rac-vm03.fqdn.local':'161' cefSwitchingPath]

CMD EXITCODE[0]
CMD RUNTIME[0.0643s]
STDOUT[
cefSwitchingPath = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
Caching OIDs:  entPhysicalDescr
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m ENTITY-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' entPhysicalDescr]

CMD EXITCODE[0]
CMD RUNTIME[0.0179s]
STDOUT[
entPhysicalDescr = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
 entPhysicalName
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m ENTITY-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' entPhysicalName]

CMD EXITCODE[0]
CMD RUNTIME[0.0165s]
STDOUT[
entPhysicalName = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]
 entPhysicalModelName
CMD[/usr/bin/snmpbulkwalk -t '10' -v2c -c *** -Pud -OQUs -m ENTITY-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'rac-vm03.fqdn.local':'161' entPhysicalModelName]

CMD EXITCODE[0]
CMD RUNTIME[0.0137s]
STDOUT[
entPhysicalModelName = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]


 o Duration             0.1178s

 o Modules Disabled     lsp, raid
 o Modules Enabled      os, mibs, ports, ports-stack, vlans, oids, cisco-vrf, ip-addresses, processors, mempools, inventory, printersupplies, 
                        sensors,storage, neighbours, arp-table, junose-atm-vp, bgp-peers, mac-accounting, sla, pseudowires, virtual-machines, 
                        cisco-cbqos,ucd-diskio, wifi, p2p-radios, graphs, cisco-cef 

SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '429';]
SQL RUNTIME[0.00025105s]

SQL[UPDATE `devices` SET `last_discovered` =NOW(),`type` ='management',`last_discovered_timetaken` ='4.1476',`force_discovery` ='0',`device_state` ='a:4:{s:15:\"poller_mod_perf\";a:29:{s:6:\"system\";d:0.2634;s:2:\"os\";d:0.2042;s:4:\"ipmi\";d:0.0033;s:7:\"sensors\";d:0.117;s:6:\"status\";d:0.1794;s:7:\"counter\";d:0.0003;s:10:\"processors\";d:0.0005;s:8:\"mempools\";d:0.0004;s:7:\"storage\";d:0.0006;s:8:\"netstats\";d:0.1451;s:7:\"ucd-mib\";d:0.0164;s:13:\"ipSystemStats\";d:0.0433;s:5:\"ports\";d:0.1163;s:9:\"bgp-peers\";d:0.0009;s:15:\"printersupplies\";d:0.0004;s:10:\"ucd-diskio\";d:0.0003;s:4:\"wifi\";d:0.0001;s:10:\"p2p-radios\";d:0.0004;s:4:\"ospf\";d:0.0174;s:3:\"sla\";d:0.0005;s:11:\"pseudowires\";d:0.0004;s:14:\"mac-accounting\";d:0.0005;s:12:\"loadbalancer\";d:0.0002;s:15:\"entity-physical\";d:0.0001;s:12:\"applications\";d:0.0003;s:9:\"fdb-table\";d:0.001;s:6:\"graphs\";d:0.0291;s:4:\"oids\";d:0.0003;s:6:\"probes\";d:0.0003;}s:14:\"poller_history\";a:57:{i:1587744430;d:1.2849;i:1587744069;d:1.0265;i:1587743817;d:11.4716;i:1587743522;d:1.557;i:1587743212;d:1.1081;i:1587742943;d:1.3414;i:1587742621;d:1.6146;i:1587742323;d:1.2611;i:1587742015;d:1.7126;i:1587741719;d:1.5904;i:1587741417;d:1.5346;i:1587741128;d:1.2097;i:1587740956;d:1.0513;i:1587740816;d:1.5136;i:1587740521;d:1.3584;i:1587740424;d:1.0861;i:1587740216;d:1.3141;i:1587739934;d:1.2279;i:1587739731;d:1.0858;i:1587739617;d:1.361;i:1587739341;d:1.5808;i:1587739294;d:0.9746;i:1587739015;d:1.5814;i:1587738675;d:1.6936;i:1587738415;d:11.2585;i:1587738120;d:1.3295;i:1587737819;d:1.3068;i:1587737517;d:1.6107;i:1587737223;d:1.5178;i:1587736923;d:1.1751;i:1587736820;d:1.0561;i:1587736583;d:0.9611;i:1587736335;d:10.9701;i:1587736009;d:1.1221;i:1587735727;d:2.3944;i:1587735411;d:1.3125;i:1587735119;d:2.2176;i:1587734964;d:1.0439;i:1587734810;d:2.0619;i:1587734524;d:2.6178;i:1587734218;d:1.4975;i:1587733917;d:1.3728;i:1587733616;d:1.0139;i:1587733344;d:1.0483;i:1587733339;d:0.8604;i:1587733034;d:0.9535;i:1587732745;d:0.8204;i:1587732589;d:0.8097;i:1587732426;d:1.3566;i:1587732252;d:0.8065;i:1587732226;d:0.8668;i:1587732151;d:1.4101;i:1587731822;d:0.822;i:1587731527;d:1.8741;i:1587731221;d:1.067;i:1587730932;d:0.839;i:1587730743;d:0.9568;}s:17:\"discovery_history\";a:17:{i:1587744653;d:4.1476;i:1587740947;d:4.1302;i:1587740416;d:4.6075;i:1587740219;d:4.4739;i:1587739738;d:4.1643;i:1587739288;d:4.6001;i:1587738823;d:4.4667;i:1587737541;d:3.5711;i:1587736789;d:6.7214;i:1587736615;d:4.6653;i:1587734954;d:3.6768;i:1587734679;d:3.8892;i:1587734518;d:4.644;i:1587733352;d:4.155;i:1587732245;d:2.97;i:1587732215;d:5.2929;i:1587730700;d:3.6389;}s:18:\"discovery_mod_perf\";a:29:{s:2:\"os\";d:0.0461;s:4:\"mibs\";d:0.0387;s:5:\"ports\";d:0.0697;s:11:\"ports-stack\";d:0.0169;s:5:\"vlans\";d:0.0015;s:11:\"ports_vlans\";N;s:4:\"oids\";d:0.0006;s:9:\"cisco-vrf\";d:0.0004;s:12:\"ip-addresses\";d:0.1105;s:10:\"processors\";d:0.041;s:8:\"mempools\";d:0.0258;s:9:\"inventory\";d:0.0982;s:15:\"printersupplies\";d:0.0005;s:7:\"sensors\";d:3.3322;s:7:\"storage\";d:0.0162;s:10:\"neighbours\";d:0.1112;s:9:\"arp-table\";d:0.0165;s:13:\"junose-atm-vp\";d:0.0002;s:9:\"bgp-peers\";d:0.0007;s:14:\"mac-accounting\";d:0.0001;s:3:\"sla\";d:0.0628;s:11:\"pseudowires\";d:0.0168;s:16:\"virtual-machines\";d:0.0004;s:11:\"cisco-cbqos\";d:0.0002;s:10:\"ucd-diskio\";d:0.0172;s:4:\"wifi\";d:0.001;s:10:\"p2p-radios\";d:0.0001;s:6:\"graphs\";d:0.0002;s:9:\"cisco-cef\";d:0.1178;}}' WHERE `device_id` = '429']
SQL RUNTIME[0.00141621s]
#####  rac-vm03.fqdn.local [429] completed discovery modules at 2020-04-24 18:10:58  #####

 o Discovery time       4.1476 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '7141' AND `process_name` = 'discovery.php' AND `device_id` = '429']
SQL RUNTIME[0.00109911s]
#####  Finished discovery run at 2020-04-24 18:10:58  #####


SQL[SELECT * FROM `groups` ORDER BY `entity_type`]
SQL RUNTIME[0.00015092s]

SQL[SELECT * FROM `groups_assoc`]
SQL RUNTIME[0.00009418s]

SQL[SELECT `device_id` FROM `devices`  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%')]
SQL RUNTIME[0.00021601s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '1']
SQL RUNTIME[0.00023293s]
Group                          'ALL devices': 164 existing, 164 new entries (+0/-0).

SQL[SELECT `port_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`)  WHERE ( IFNULL(`devices`.`hostname`, "") LIKE '%') AND `ports`.`deleted` != '1']
SQL RUNTIME[0.00511003s]

SQL[SELECT DISTINCT `entity_id` FROM `group_table` WHERE 1 AND `group_id` = '2']
SQL RUNTIME[0.00411296s]
Group                            'ALL ports': 7569 existing, 7569 new entries (+0/-0).

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00025296s]
Cached 6 alert rules.

SQL[SELECT * FROM `alert_assoc`]
SQL RUNTIME[0.00010705s]

SQL[SELECT `port_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`os`, "") LIKE 'procurve') AND ( 1 AND `ifAdminStatus` = 'up' AND `ifType` != 'propMultiplexor' AND `ifType` != 'ieee8023adLag' AND `ifType` != 'propVirtual'))) AND `deleted` != '1']
SQL RUNTIME[0.00584412s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '3']
SQL RUNTIME[0.00254297s]
Alert Checker             'Greater than 75%': 1029 existing, 1029 new entries (+0/-0).

SQL[SELECT `port_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `ports`  LEFT JOIN `devices` ON (`ports`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1 AND IFNULL(`devices`.`hostname`, "") LIKE 'swi%') AND ( 1 AND `ifAdminStatus` = 'up' AND `ifType` != 'propMultiplexor' AND `ifType` != 'ieee8023adLag' AND `ifType` != 'propVirtual'))) AND `deleted` != '1']
SQL RUNTIME[0.00203085s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '5']
SQL RUNTIME[0.00061417s]
Alert Checker              'GLO Port Errors': 182 existing, 182 new entries (+0/-0).

SQL[SELECT `device_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `devices` WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1)))]
SQL RUNTIME[0.00082397s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '6']
SQL RUNTIME[0.00041389s]
Alert Checker                       'sfdsdf': 108 existing, 108 new entries (+0/-0).

SQL[SELECT `device_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `devices` WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1)))]
SQL RUNTIME[0.00029111s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '7']
SQL RUNTIME[0.00037503s]
Alert Checker                      'Testing': 108 existing, 108 new entries (+0/-0).

SQL[SELECT `sensor_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `sensors`  LEFT JOIN `devices` ON (`sensors`.`device_id` = `devices`.`device_id`) WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1))) AND `sensor_deleted` != '1']
SQL RUNTIME[0.00314999s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '8']
SQL RUNTIME[0.00218415s]
Alert Checker                             '': 873 existing, 873 new entries (+0/-0).

SQL[SELECT `device_id` AS `entity_id`, `devices`.`device_id` as `device_id` FROM `devices` WHERE `devices`.`ignore` = '0' AND `devices`.`disabled` = '0' AND ( (( 1) AND ( 1)))]
SQL RUNTIME[0.00044179s]

SQL[SELECT * FROM `alert_table` WHERE `alert_test_id` = '9']
SQL RUNTIME[0.00062394s]
Alert Checker                  'Device down': 108 existing, 108 new entries (+0/-0).
./discovery.php: rac-vm03* - 1 devices discovered in 4.243 secs

SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1587730253']
SQL RUNTIME[0.00020599s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       4.243 secs
 o Memory usage         26MB (peak: 26MB)
 o MySQL Usage          Cell[70/0.023s] Row[79/0.024s] Rows[85/0.055s] Column[3/0.007s] Update[6/0.008s] Insert[6/0.008s] Delete[1/0.001s] 
 o RRDTool Usage