DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0338s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9910 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 9910 Last Changed Date: 2019-05-22 21:59:43 +0200 (Wed, 22 May 2019) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00043511s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00009203s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00011420s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00020194s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 19.5.9910 http://www.observium.org CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[1.5869s] STDOUT[ Linux|3.10.0-514.6.1.el7.x86_64|amd64|CentOS|7|vmware| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0123s] STDOUT[ Python 2.7.5 ] SQL[SELECT version();] SQL RUNTIME[0.11867309s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0167s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[1.382s] STDOUT[ RRDtool 1.4.8 Copyright 1997-2013 by Tobias Oetiker ] CMD[/usr/bin/rrdcached -h | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0728s] STDOUT[ RRDCacheD 1.4.8 ] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0392s] STDOUT[ ] CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0551s] STDOUT[ Apache/2.4.6 ] CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0131s] STDOUT[ +02:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00157189s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00030994s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.13122416s] ##### Software versions ##### o OS Linux 3.10.0-514.6.1.el7.x86_64 [amd64] (CentOS 7) o Apache 2.4.6 o PHP 7.1.22 (OPcache: ENABLED) o Python 2.7.5 o MySQL 5.5.60-MariaDB (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.2 o RRDtool 1.4.8 (rrdcached 1.4.8: unix:/var/rrdtool/rrdcached/rrdcached.sock) o Fping ##### Memory Limit ##### o PHP 4GB ##### MySQL mode ##### o MySQL ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Thursday, 23-May-19 12:32:17 CEST o PHP +02:00 o MySQL +02:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00169277s] HTTP requests disabled, since PHP config option "allow_url_fopen" set to off. Please enable this option in your PHP config. REQUEST[http://www.observium.org/versions.php] REQUEST STATUS[FALSE] RESPONSE CODE[400 HTTP Method Disabled] SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck')] SQL RUNTIME[0.00029516s] SQL[UPDATE `observium_attribs` set `attrib_value` ='1558607537' WHERE `attrib_type` = 'last_versioncheck'] SQL RUNTIME[0.01031494s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00198913s] ##### Starting discovery run at 2019-05-23 12:32:17 ##### SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'ups-man-f1' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.01295304s] CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups-man-f1':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0378s] STDOUT[ sysObjectID.0 = enterprises.935.1.1.1 sysUpTime.0 = 3:19:19:16.94 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '267'] SQL RUNTIME[0.00120401s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '267'] SQL RUNTIME[0.00029492s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('22407','discovery.php','19778','0','php ./discovery.php -d -m sensors -h ups-man-f1','1558607533','267')] SQL RUNTIME[0.01039505s] ##### ups-man-f1 [267] ##### o OS Type netagent o OS Group ups o SNMP Version v2c o Last discovery 2019-05-23 10:11:22 o Last duration 17.62 seconds ##### Module Start: sensors ##### SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '267' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00087094s] o ENTITY-SENSOR-MIB CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups-man-f1':'161' entPhySensorValue] CMD EXITCODE[0] CMD RUNTIME[0.1791s] STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o XPPC-MIB upsThreePhaseBatteryTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryTemperature] CMD EXITCODE[0] CMD RUNTIME[0.1534s] STDOUT[ upsThreePhaseBatteryTemperature.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryTemperature CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryTemperature'] CMD EXITCODE[0] CMD RUNTIME[0.0256s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.1.5 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryTemperature' -> '.1.3.6.1.4.1.935.1.1.1.8.1.5' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBatteryCapacityPercentage [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryCapacityPercentage] CMD EXITCODE[0] CMD RUNTIME[0.1562s] STDOUT[ upsThreePhaseBatteryCapacityPercentage.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryCapacityPercentage CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryCapacityPercentage'] CMD EXITCODE[0] CMD RUNTIME[0.0305s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.1.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryCapacityPercentage' -> '.1.3.6.1.4.1.935.1.1.1.8.1.2' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBatteryVoltage [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryVoltage] CMD EXITCODE[0] CMD RUNTIME[0.1998s] STDOUT[ upsThreePhaseBatteryVoltage.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryVoltage CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryVoltage'] CMD EXITCODE[0] CMD RUNTIME[0.0275s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.1.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryVoltage' -> '.1.3.6.1.4.1.935.1.1.1.8.1.1' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBatteryCurrent [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryCurrent] CMD EXITCODE[0] CMD RUNTIME[0.3904s] STDOUT[ upsThreePhaseBatteryCurrent.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryCurrent CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryCurrent'] CMD EXITCODE[0] CMD RUNTIME[0.0208s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.1.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryCurrent' -> '.1.3.6.1.4.1.935.1.1.1.8.1.4' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBatteryTimeRemain [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryTimeRemain] CMD EXITCODE[0] CMD RUNTIME[0.1767s] STDOUT[ upsThreePhaseBatteryTimeRemain.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryTimeRemain CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryTimeRemain'] CMD EXITCODE[0] CMD RUNTIME[0.23s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.1.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryTimeRemain' -> '.1.3.6.1.4.1.935.1.1.1.8.1.3' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseInputFrequency [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputFrequency] CMD EXITCODE[0] CMD RUNTIME[0.2173s] STDOUT[ upsThreePhaseInputFrequency.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseInputFrequency CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputFrequency'] CMD EXITCODE[0] CMD RUNTIME[0.0341s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.2.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.2.1' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseInputVoltageR [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageR] CMD EXITCODE[0] CMD RUNTIME[0.2534s] STDOUT[ upsThreePhaseInputVoltageR.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageR CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageR'] CMD EXITCODE[0] CMD RUNTIME[0.0347s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.2.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.2.2' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseInputVoltageS [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageS] CMD EXITCODE[0] CMD RUNTIME[0.2294s] STDOUT[ upsThreePhaseInputVoltageS.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageS CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageS'] CMD EXITCODE[0] CMD RUNTIME[0.0317s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.2.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.2.3' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseInputVoltageT [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageT] CMD EXITCODE[0] CMD RUNTIME[0.4336s] STDOUT[ upsThreePhaseInputVoltageT.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageT CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageT'] CMD EXITCODE[0] CMD RUNTIME[0.0319s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.2.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.2.4' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputFrequency [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputFrequency] CMD EXITCODE[0] CMD RUNTIME[0.2253s] STDOUT[ upsThreePhaseOutputFrequency.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputFrequency CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputFrequency'] CMD EXITCODE[0] CMD RUNTIME[0.0551s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.3.1' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputVoltageR [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageR] CMD EXITCODE[0] CMD RUNTIME[0.1854s] STDOUT[ upsThreePhaseOutputVoltageR.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageR CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageR'] CMD EXITCODE[0] CMD RUNTIME[0.0309s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.3.2' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputVoltageS [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageS] CMD EXITCODE[0] CMD RUNTIME[0.1738s] STDOUT[ upsThreePhaseOutputVoltageS.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageS CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageS'] CMD EXITCODE[0] CMD RUNTIME[0.0377s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.3.3' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputVoltageT [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageT] CMD EXITCODE[0] CMD RUNTIME[0.1849s] STDOUT[ upsThreePhaseOutputVoltageT.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageT CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageT'] CMD EXITCODE[0] CMD RUNTIME[0.0494s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.3.4' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputLoadPercentageR [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageR] CMD EXITCODE[0] CMD RUNTIME[0.2746s] STDOUT[ upsThreePhaseOutputLoadPercentageR.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageR CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageR'] CMD EXITCODE[0] CMD RUNTIME[0.0289s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.5 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageR' -> '.1.3.6.1.4.1.935.1.1.1.8.3.5' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputLoadPercentageS [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageS] CMD EXITCODE[0] CMD RUNTIME[0.4162s] STDOUT[ upsThreePhaseOutputLoadPercentageS.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageS CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageS'] CMD EXITCODE[0] CMD RUNTIME[0.0249s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.6 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageS' -> '.1.3.6.1.4.1.935.1.1.1.8.3.6' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseOutputLoadPercentageT [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageT] CMD EXITCODE[0] CMD RUNTIME[0.1733s] STDOUT[ upsThreePhaseOutputLoadPercentageT.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageT CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageT'] CMD EXITCODE[0] CMD RUNTIME[0.0254s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.3.7 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageT' -> '.1.3.6.1.4.1.935.1.1.1.8.3.7' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBypassSourceFrequency [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceFrequency] CMD EXITCODE[0] CMD RUNTIME[0.2781s] STDOUT[ upsThreePhaseBypassSourceFrequency.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceFrequency CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceFrequency'] CMD EXITCODE[0] CMD RUNTIME[0.0287s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.4.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.4.1' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBypassSourceVoltageR [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageR] CMD EXITCODE[0] CMD RUNTIME[0.152s] STDOUT[ upsThreePhaseBypassSourceVoltageR.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageR CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageR'] CMD EXITCODE[0] CMD RUNTIME[0.0272s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.4.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.4.2' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBypassSourceVoltageS [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageS] CMD EXITCODE[0] CMD RUNTIME[0.1542s] STDOUT[ upsThreePhaseBypassSourceVoltageS.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageS CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageS'] CMD EXITCODE[0] CMD RUNTIME[0.0256s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.4.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.4.3' Excluded by current value (0) is equals or below min (0). ] upsThreePhaseBypassSourceVoltageT [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageT] CMD EXITCODE[0] CMD RUNTIME[0.2196s] STDOUT[ upsThreePhaseBypassSourceVoltageT.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageT CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageT'] CMD EXITCODE[0] CMD RUNTIME[0.0372s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.8.4.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.4.4' Excluded by current value (0) is equals or below min (0). ] upsSmartBatteryTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryTemperature] CMD EXITCODE[0] CMD RUNTIME[0.357s] STDOUT[ upsSmartBatteryTemperature.0 = 156 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartBatteryTemperature CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryTemperature'] CMD EXITCODE[0] CMD RUNTIME[0.0445s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.2.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryTemperature' -> '.1.3.6.1.4.1.935.1.1.1.2.2.3' Discover sensor: [class: temperature, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.3.0, index: 0, type: XPPC-MIB-upsSmartBatteryTemperature, descr: Battery Temperature, scale: 0.1, limits: (, , , ), CURRENT: 15.6, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryTemperature' AND `sensor_index` = '0')] SQL RUNTIME[0.00450301s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryTemperature' AND `sensor_index` = '0'] SQL RUNTIME[0.00087786s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8652' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00035596s] .] upsSmartBatteryCapacity [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryCapacity] CMD EXITCODE[0] CMD RUNTIME[0.1958s] STDOUT[ upsSmartBatteryCapacity.0 = 100 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartBatteryCapacity CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryCapacity'] CMD EXITCODE[0] CMD RUNTIME[0.031s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.2.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryCapacity' -> '.1.3.6.1.4.1.935.1.1.1.2.2.1' Discover sensor: [class: capacity, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.1.0, index: 0, type: XPPC-MIB-upsSmartBatteryCapacity, descr: Battery Capacity, scale: 1, limits: (10, 25, , ), CURRENT: 100, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryCapacity' AND `sensor_index` = '0')] SQL RUNTIME[0.00114489s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryCapacity' AND `sensor_index` = '0'] SQL RUNTIME[0.00054884s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8653' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00028110s] .] upsSmartBatteryVoltage [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryVoltage] CMD EXITCODE[0] CMD RUNTIME[0.1638s] STDOUT[ upsSmartBatteryVoltage.0 = 820 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartBatteryVoltage CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryVoltage'] CMD EXITCODE[0] CMD RUNTIME[0.027s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.2.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryVoltage' -> '.1.3.6.1.4.1.935.1.1.1.2.2.2' Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.2.0, index: 0, type: XPPC-MIB-upsSmartBatteryVoltage, descr: Battery Voltage, scale: 1, limits: (, , , ), CURRENT: 820, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00146914s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00094509s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8654' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00023603s] .] upsSmartBatteryCurrent [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryCurrent] CMD EXITCODE[0] CMD RUNTIME[0.1574s] STDOUT[ upsSmartBatteryCurrent.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartBatteryCurrent CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryCurrent'] CMD EXITCODE[0] CMD RUNTIME[0.0377s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.2.7 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryCurrent' -> '.1.3.6.1.4.1.935.1.1.1.2.2.7' Excluded by current value (0) is equals or below min (0). ] upsSmartBatteryRunTimeRemaining [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryRunTimeRemaining] CMD EXITCODE[0] CMD RUNTIME[0.1735s] STDOUT[ upsSmartBatteryRunTimeRemaining.0 = 780 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartBatteryRunTimeRemaining CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryRunTimeRemaining'] CMD EXITCODE[0] CMD RUNTIME[0.03s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.2.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryRunTimeRemaining' -> '.1.3.6.1.4.1.935.1.1.1.2.2.4' Discover sensor: [class: runtime, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.4.0, index: 0, type: XPPC-MIB-upsSmartBatteryRunTimeRemaining, descr: Battery Runtime, scale: 0.016666666666667, limits: (3, 10, , ), CURRENT: 13, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryRunTimeRemaining' AND `sensor_index` = '0')] SQL RUNTIME[0.00144410s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryRunTimeRemaining' AND `sensor_index` = '0'] SQL RUNTIME[0.00312901s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '10518' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00032091s] .] upsSmartInputFrequency [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputFrequency] CMD EXITCODE[0] CMD RUNTIME[0.1573s] STDOUT[ upsSmartInputFrequency.0 = 500 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartInputFrequency CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputFrequency'] CMD EXITCODE[0] CMD RUNTIME[0.0575s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.3.2.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.3.2.4' Discover sensor: [class: frequency, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.4.0, index: 0, type: XPPC-MIB-upsSmartInputFrequency, descr: Input Frequency, scale: 0.1, limits: (, , , ), CURRENT: 50, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputFrequency' AND `sensor_index` = '0')] SQL RUNTIME[0.00223804s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputFrequency' AND `sensor_index` = '0'] SQL RUNTIME[0.00103688s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8655' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00052190s] .] upsSmartInputLineVoltage [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputLineVoltage] CMD EXITCODE[0] CMD RUNTIME[0.2032s] STDOUT[ upsSmartInputLineVoltage.0 = 2231 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartInputLineVoltage CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputLineVoltage'] CMD EXITCODE[0] CMD RUNTIME[0.049s] CMD EXITDELAY[10ms] STDOUT[ .1.3.6.1.4.1.935.1.1.1.3.2.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputLineVoltage' -> '.1.3.6.1.4.1.935.1.1.1.3.2.1' Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.1.0, index: 0, type: XPPC-MIB-upsSmartInputLineVoltage, descr: Input Voltage, scale: 0.1, limits: (, , , ), CURRENT: 223.1, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputLineVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00372696s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputLineVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00095105s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8656' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00185204s] .] upsSmartOutputFrequency [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputFrequency] CMD EXITCODE[0] CMD RUNTIME[0.1313s] STDOUT[ upsSmartOutputFrequency.0 = 500 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartOutputFrequency CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputFrequency'] CMD EXITCODE[0] CMD RUNTIME[0.0299s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.4.2.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.4.2.2' Discover sensor: [class: frequency, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.2.0, index: 0, type: XPPC-MIB-upsSmartOutputFrequency, descr: Output Frequency, scale: 0.1, limits: (, , , ), CURRENT: 50, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputFrequency' AND `sensor_index` = '0')] SQL RUNTIME[0.01416492s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputFrequency' AND `sensor_index` = '0'] SQL RUNTIME[0.00142288s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8657' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00042105s] .] upsSmartOutputVoltage [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputVoltage] CMD EXITCODE[0] CMD RUNTIME[0.3081s] STDOUT[ upsSmartOutputVoltage.0 = 2230 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartOutputVoltage CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputVoltage'] CMD EXITCODE[0] CMD RUNTIME[0.0882s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.4.2.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputVoltage' -> '.1.3.6.1.4.1.935.1.1.1.4.2.1' Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.1.0, index: 0, type: XPPC-MIB-upsSmartOutputVoltage, descr: Output Voltage, scale: 0.1, limits: (, , , ), CURRENT: 223, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00112104s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00053000s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8658' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00019813s] .] upsSmartOutputLoad [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputLoad] CMD EXITCODE[0] CMD RUNTIME[0.195s] STDOUT[ upsSmartOutputLoad.0 = 44 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartOutputLoad CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputLoad'] CMD EXITCODE[0] CMD RUNTIME[0.0703s] CMD EXITDELAY[10ms] STDOUT[ .1.3.6.1.4.1.935.1.1.1.4.2.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputLoad' -> '.1.3.6.1.4.1.935.1.1.1.4.2.3' Discover sensor: [class: load, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.3.0, index: 0, type: XPPC-MIB-upsSmartOutputLoad, descr: Output Load, scale: 1, limits: (, , 80, 95), CURRENT: 44, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputLoad' AND `sensor_index` = '0')] SQL RUNTIME[0.00940394s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputLoad' AND `sensor_index` = '0'] SQL RUNTIME[0.00086689s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8659' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00021219s] .] upsEnvTemperature [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvTemperature] CMD EXITCODE[0] CMD RUNTIME[0.1938s] STDOUT[ upsEnvTemperature.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvTemperature CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvUnderTemperature.0] CMD EXITCODE[0] CMD RUNTIME[0.1626s] STDOUT[ upsEnvUnderTemperature.0 = 50 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvUnderTemperature.0 CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvOverTemperature.0] CMD EXITCODE[0] CMD RUNTIME[0.2184s] STDOUT[ upsEnvOverTemperature.0 = 700 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvOverTemperature.0 CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvTemperature'] CMD EXITCODE[0] CMD RUNTIME[0.1329s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.9.1.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvTemperature' -> '.1.3.6.1.4.1.935.1.1.1.9.1.1' Excluded by current value (0) is equals or below min (0). ] upsEnvHumidity [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvHumidity] CMD EXITCODE[0] CMD RUNTIME[0.2525s] STDOUT[ upsEnvHumidity.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvHumidity CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvUnderHumidity.0] CMD EXITCODE[0] CMD RUNTIME[0.199s] STDOUT[ upsEnvUnderHumidity.0 = 5 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvUnderHumidity.0 CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvOverHumidity.0] CMD EXITCODE[0] CMD RUNTIME[0.229s] STDOUT[ upsEnvOverHumidity.0 = 90 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvOverHumidity.0 CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvHumidity'] CMD EXITCODE[0] CMD RUNTIME[0.0313s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.9.1.2 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvHumidity' -> '.1.3.6.1.4.1.935.1.1.1.9.1.2' Excluded by current value (0) is equals or below min (0). ] o XPPC-MIB upsBaseBatteryStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsBaseBatteryStatus] CMD EXITCODE[0] CMD RUNTIME[0.1575s] STDOUT[ upsBaseBatteryStatus.0 = batteryNormal ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsBaseBatteryStatus CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsBaseBatteryStatus'] CMD EXITCODE[0] CMD RUNTIME[0.0763s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.2.1.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsBaseBatteryStatus' -> '.1.3.6.1.4.1.935.1.1.1.2.1.1' Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.1.1.0, index: 0, type: upsBaseBatteryStatus, descr: Battery Status, CURRENT: 2, , battery] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseBatteryStatus' AND `status_type` = 'upsBaseBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00189614s] SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseBatteryStatus' AND `status_type` = 'upsBaseBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00067115s] .] upsSmartInputLineFailCause [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputLineFailCause] CMD EXITCODE[0] CMD RUNTIME[0.1958s] STDOUT[ upsSmartInputLineFailCause.0 = noTransfer ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsSmartInputLineFailCause CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputLineFailCause'] CMD EXITCODE[0] CMD RUNTIME[0.0284s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.3.2.5 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputLineFailCause' -> '.1.3.6.1.4.1.935.1.1.1.3.2.5' Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.5.0, index: 0, type: upsSmartInputLineFailCause, descr: Last Input Fail Cause, CURRENT: 1, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsSmartInputLineFailCause' AND `status_type` = 'upsSmartInputLineFailCause' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00131702s] SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsSmartInputLineFailCause' AND `status_type` = 'upsSmartInputLineFailCause' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00057292s] .] upsBaseOutputStatus [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsBaseOutputStatus] CMD EXITCODE[0] CMD RUNTIME[0.1774s] STDOUT[ upsBaseOutputStatus.0 = standBy ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsBaseOutputStatus CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsBaseOutputStatus'] CMD EXITCODE[0] CMD RUNTIME[0.0285s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.4.1.1 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsBaseOutputStatus' -> '.1.3.6.1.4.1.935.1.1.1.4.1.1' Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.1.1.0, index: 0, type: upsBaseOutputStatus, descr: Output Status, CURRENT: 8, , other] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseOutputStatus' AND `status_type` = 'upsBaseOutputStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00190187s] SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseOutputStatus' AND `status_type` = 'upsBaseOutputStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00074506s] .] upsEnvWater [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvWater] CMD EXITCODE[0] CMD RUNTIME[0.1616s] STDOUT[ upsEnvWater.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvWater CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvWater'] CMD EXITCODE[0] CMD RUNTIME[0.0276s] CMD EXITDELAY[10ms] STDOUT[ .1.3.6.1.4.1.935.1.1.1.9.1.3 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvWater' -> '.1.3.6.1.4.1.935.1.1.1.9.1.3' Skipped by unknown state value: 0, Sensor Water ] upsEnvSmoke [ CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvSmoke] CMD EXITCODE[0] CMD RUNTIME[0.1392s] STDOUT[ upsEnvSmoke.0 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: XPPC-MIB::upsEnvSmoke CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvSmoke'] CMD EXITCODE[0] CMD RUNTIME[0.0493s] STDOUT[ .1.3.6.1.4.1.935.1.1.1.9.1.4 ] SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvSmoke' -> '.1.3.6.1.4.1.935.1.1.1.9.1.4' Skipped by unknown state value: 0, Sensor Smoke ] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.01301908s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00112987s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00043988s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00031900s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00024796s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00056791s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030589s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00030398s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00023794s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022602s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00023198s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00023198s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00027490s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029492s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00042892s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00042701s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00130606s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00064397s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00025392s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00035501s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00076914s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00035810s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00032210s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00031805s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00033402s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00029206s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00022388s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00035286s] SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00037909s] SQL[SELECT * FROM `counters` WHERE `device_id` = '267' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'] SQL RUNTIME[0.00029302s] o Duration 11.5103s SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='11.5235',`force_discovery` ='0' WHERE `device_id` = '267'] SQL RUNTIME[0.13439202s] ##### ups-man-f1 [267] completed discovery modules at 2019-05-23 12:32:29 ##### o Discovery time 11.5235 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '22407' AND `process_name` = 'discovery.php' AND `device_id` = '267'] SQL RUNTIME[0.08766794s] ##### Finished discovery run at 2019-05-23 12:32:29 ##### ./discovery.php: ups-man-f1 - 1 devices discovered in 15.34 secs SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1558593134'] SQL RUNTIME[0.00081110s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Discovered 1 o Discovery Time 15.34 secs o Memory usage 4MB (peak: 4MB) o MySQL Usage Cell[17/0.175s] Row[25/0.027s] Rows[37/0.181s] Column[1/0.001s] Update[2/0.148s] Insert[1/0.011s] Delete[1/0.088s]