DEBUG!

CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0338s]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: http://svn.observium.org/svn/observium/trunk
Repository Root: http://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 9910
Node Kind: directory
Schedule: normal
Last Changed Author: mike
Last Changed Rev: 9910
Last Changed Date: 2019-05-22 21:59:43 +0200 (Wed, 22 May 2019)

]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00043511s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00009203s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00011420s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00020194s]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                           Observium Professional 19.5.9910
                                   http://www.observium.org


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[1.5869s]
STDOUT[
Linux|3.10.0-514.6.1.el7.x86_64|amd64|CentOS|7|vmware|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0123s]
STDOUT[
Python 2.7.5
]

SQL[SELECT version();]
SQL RUNTIME[0.11867309s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0167s]
STDOUT[
NET-SNMP version: 5.7.2
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[1.382s]
STDOUT[
RRDtool 1.4.8  Copyright 1997-2013 by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/rrdcached -h | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0728s]
STDOUT[
RRDCacheD 1.4.8
]

CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0392s]
STDOUT[

]

CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0551s]
STDOUT[
Apache/2.4.6
]

CMD[date "+%:z"]

CMD EXITCODE[0]
CMD RUNTIME[0.0131s]
STDOUT[
+02:00
]

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00157189s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00030994s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.13122416s]

#####  Software versions  #####

 o OS                   Linux 3.10.0-514.6.1.el7.x86_64 [amd64] (CentOS 7)
 o Apache               2.4.6
 o PHP                  7.1.22 (OPcache: ENABLED)
 o Python               2.7.5
 o MySQL                5.5.60-MariaDB (extension: mysqli 5.0.12-dev)
 o SNMP                 NET-SNMP 5.7.2
 o RRDtool              1.4.8 (rrdcached 1.4.8: unix:/var/rrdtool/rrdcached/rrdcached.sock)
 o Fping

#####  Memory Limit  #####

 o PHP                  4GB

#####  MySQL mode  #####

 o MySQL

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8

#####  Timezones info  #####

 o Date                 Thursday, 23-May-19 12:32:17 CEST
 o PHP                  +02:00
 o MySQL                +02:00


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';]
SQL RUNTIME[0.00169277s]
HTTP requests disabled, since PHP config option "allow_url_fopen" set to off. Please enable this option in your PHP config.

REQUEST[http://www.observium.org/versions.php]
REQUEST STATUS[FALSE]
RESPONSE CODE[400 HTTP Method Disabled]

SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck')]
SQL RUNTIME[0.00029516s]

SQL[UPDATE `observium_attribs` set `attrib_value` ='1558607537' WHERE `attrib_type` = 'last_versioncheck']
SQL RUNTIME[0.01031494s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00198913s]
#####  Starting discovery run at 2019-05-23 12:32:17  #####


SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'ups-man-f1' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC]
SQL RUNTIME[0.01295304s]

CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups-man-f1':'161' sysObjectID.0 sysUpTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0378s]
STDOUT[
sysObjectID.0 = enterprises.935.1.1.1
sysUpTime.0 = 3:19:19:16.94
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '267']
SQL RUNTIME[0.00120401s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '267']
SQL RUNTIME[0.00029492s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`)  VALUES ('22407','discovery.php','19778','0','php ./discovery.php -d -m sensors -h ups-man-f1','1558607533','267')]
SQL RUNTIME[0.01039505s]
#####  ups-man-f1 [267]  #####

 o OS Type              netagent
 o OS Group             ups
 o SNMP Version         v2c
 o Last discovery       2019-05-23 10:11:22
 o Last duration        17.62 seconds

#####  Module Start: sensors  #####


SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '267' AND `use` = 'mib' AND `disabled` = '1']
SQL RUNTIME[0.00087094s]
 o ENTITY-SENSOR-MIB
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'ups-man-f1':'161' entPhySensorValue]

CMD EXITCODE[0]
CMD RUNTIME[0.1791s]
STDOUT[
entPhySensorValue = No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

 o XPPC-MIB             upsThreePhaseBatteryTemperature [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.1534s]
STDOUT[
upsThreePhaseBatteryTemperature.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryTemperature

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryTemperature']

CMD EXITCODE[0]
CMD RUNTIME[0.0256s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.1.5
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryTemperature' -> '.1.3.6.1.4.1.935.1.1.1.8.1.5'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBatteryCapacityPercentage [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryCapacityPercentage]

CMD EXITCODE[0]
CMD RUNTIME[0.1562s]
STDOUT[
upsThreePhaseBatteryCapacityPercentage.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryCapacityPercentage

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryCapacityPercentage']

CMD EXITCODE[0]
CMD RUNTIME[0.0305s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.1.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryCapacityPercentage' -> '.1.3.6.1.4.1.935.1.1.1.8.1.2'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBatteryVoltage [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.1998s]
STDOUT[
upsThreePhaseBatteryVoltage.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryVoltage

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryVoltage']

CMD EXITCODE[0]
CMD RUNTIME[0.0275s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.1.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryVoltage' -> '.1.3.6.1.4.1.935.1.1.1.8.1.1'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBatteryCurrent [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryCurrent]

CMD EXITCODE[0]
CMD RUNTIME[0.3904s]
STDOUT[
upsThreePhaseBatteryCurrent.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryCurrent

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryCurrent']

CMD EXITCODE[0]
CMD RUNTIME[0.0208s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.1.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryCurrent' -> '.1.3.6.1.4.1.935.1.1.1.8.1.4'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBatteryTimeRemain [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBatteryTimeRemain]

CMD EXITCODE[0]
CMD RUNTIME[0.1767s]
STDOUT[
upsThreePhaseBatteryTimeRemain.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBatteryTimeRemain

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBatteryTimeRemain']

CMD EXITCODE[0]
CMD RUNTIME[0.23s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.1.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBatteryTimeRemain' -> '.1.3.6.1.4.1.935.1.1.1.8.1.3'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseInputFrequency [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputFrequency]

CMD EXITCODE[0]
CMD RUNTIME[0.2173s]
STDOUT[
upsThreePhaseInputFrequency.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseInputFrequency

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputFrequency']

CMD EXITCODE[0]
CMD RUNTIME[0.0341s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.2.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.2.1'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseInputVoltageR [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageR]

CMD EXITCODE[0]
CMD RUNTIME[0.2534s]
STDOUT[
upsThreePhaseInputVoltageR.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageR

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageR']

CMD EXITCODE[0]
CMD RUNTIME[0.0347s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.2.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.2.2'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseInputVoltageS [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageS]

CMD EXITCODE[0]
CMD RUNTIME[0.2294s]
STDOUT[
upsThreePhaseInputVoltageS.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageS

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageS']

CMD EXITCODE[0]
CMD RUNTIME[0.0317s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.2.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.2.3'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseInputVoltageT [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseInputVoltageT]

CMD EXITCODE[0]
CMD RUNTIME[0.4336s]
STDOUT[
upsThreePhaseInputVoltageT.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseInputVoltageT

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseInputVoltageT']

CMD EXITCODE[0]
CMD RUNTIME[0.0319s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.2.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseInputVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.2.4'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputFrequency [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputFrequency]

CMD EXITCODE[0]
CMD RUNTIME[0.2253s]
STDOUT[
upsThreePhaseOutputFrequency.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputFrequency

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputFrequency']

CMD EXITCODE[0]
CMD RUNTIME[0.0551s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.3.1'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputVoltageR [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageR]

CMD EXITCODE[0]
CMD RUNTIME[0.1854s]
STDOUT[
upsThreePhaseOutputVoltageR.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageR

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageR']

CMD EXITCODE[0]
CMD RUNTIME[0.0309s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.3.2'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputVoltageS [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageS]

CMD EXITCODE[0]
CMD RUNTIME[0.1738s]
STDOUT[
upsThreePhaseOutputVoltageS.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageS

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageS']

CMD EXITCODE[0]
CMD RUNTIME[0.0377s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.3.3'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputVoltageT [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputVoltageT]

CMD EXITCODE[0]
CMD RUNTIME[0.1849s]
STDOUT[
upsThreePhaseOutputVoltageT.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputVoltageT

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputVoltageT']

CMD EXITCODE[0]
CMD RUNTIME[0.0494s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.3.4'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputLoadPercentageR [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageR]

CMD EXITCODE[0]
CMD RUNTIME[0.2746s]
STDOUT[
upsThreePhaseOutputLoadPercentageR.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageR

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageR']

CMD EXITCODE[0]
CMD RUNTIME[0.0289s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.5
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageR' -> '.1.3.6.1.4.1.935.1.1.1.8.3.5'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputLoadPercentageS [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageS]

CMD EXITCODE[0]
CMD RUNTIME[0.4162s]
STDOUT[
upsThreePhaseOutputLoadPercentageS.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageS

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageS']

CMD EXITCODE[0]
CMD RUNTIME[0.0249s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.6
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageS' -> '.1.3.6.1.4.1.935.1.1.1.8.3.6'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseOutputLoadPercentageT [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseOutputLoadPercentageT]

CMD EXITCODE[0]
CMD RUNTIME[0.1733s]
STDOUT[
upsThreePhaseOutputLoadPercentageT.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseOutputLoadPercentageT

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseOutputLoadPercentageT']

CMD EXITCODE[0]
CMD RUNTIME[0.0254s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.3.7
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseOutputLoadPercentageT' -> '.1.3.6.1.4.1.935.1.1.1.8.3.7'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBypassSourceFrequency [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceFrequency]

CMD EXITCODE[0]
CMD RUNTIME[0.2781s]
STDOUT[
upsThreePhaseBypassSourceFrequency.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceFrequency

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceFrequency']

CMD EXITCODE[0]
CMD RUNTIME[0.0287s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.4.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceFrequency' -> '.1.3.6.1.4.1.935.1.1.1.8.4.1'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBypassSourceVoltageR [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageR]

CMD EXITCODE[0]
CMD RUNTIME[0.152s]
STDOUT[
upsThreePhaseBypassSourceVoltageR.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageR

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageR']

CMD EXITCODE[0]
CMD RUNTIME[0.0272s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.4.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageR' -> '.1.3.6.1.4.1.935.1.1.1.8.4.2'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBypassSourceVoltageS [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageS]

CMD EXITCODE[0]
CMD RUNTIME[0.1542s]
STDOUT[
upsThreePhaseBypassSourceVoltageS.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageS

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageS']

CMD EXITCODE[0]
CMD RUNTIME[0.0256s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.4.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageS' -> '.1.3.6.1.4.1.935.1.1.1.8.4.3'
Excluded by current value (0) is equals or below min (0).
] upsThreePhaseBypassSourceVoltageT [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsThreePhaseBypassSourceVoltageT]

CMD EXITCODE[0]
CMD RUNTIME[0.2196s]
STDOUT[
upsThreePhaseBypassSourceVoltageT.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsThreePhaseBypassSourceVoltageT

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsThreePhaseBypassSourceVoltageT']

CMD EXITCODE[0]
CMD RUNTIME[0.0372s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.8.4.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsThreePhaseBypassSourceVoltageT' -> '.1.3.6.1.4.1.935.1.1.1.8.4.4'
Excluded by current value (0) is equals or below min (0).
] upsSmartBatteryTemperature [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.357s]
STDOUT[
upsSmartBatteryTemperature.0 = 156
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartBatteryTemperature

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryTemperature']

CMD EXITCODE[0]
CMD RUNTIME[0.0445s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.2.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryTemperature' -> '.1.3.6.1.4.1.935.1.1.1.2.2.3'
Discover sensor: [class: temperature, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.3.0, index: 0, type: XPPC-MIB-upsSmartBatteryTemperature, descr: Battery Temperature, scale: 0.1, limits: (, , , ), CURRENT: 15.6, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryTemperature' AND `sensor_index` = '0')]
SQL RUNTIME[0.00450301s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryTemperature' AND `sensor_index` = '0']
SQL RUNTIME[0.00087786s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8652' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00035596s]
.] upsSmartBatteryCapacity [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryCapacity]

CMD EXITCODE[0]
CMD RUNTIME[0.1958s]
STDOUT[
upsSmartBatteryCapacity.0 = 100
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartBatteryCapacity

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryCapacity']

CMD EXITCODE[0]
CMD RUNTIME[0.031s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.2.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryCapacity' -> '.1.3.6.1.4.1.935.1.1.1.2.2.1'
Discover sensor: [class: capacity, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.1.0, index: 0, type: XPPC-MIB-upsSmartBatteryCapacity, descr: Battery Capacity, scale: 1, limits: (10, 25, , ), CURRENT: 100, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'capacity' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryCapacity' AND `sensor_index` = '0')]
SQL RUNTIME[0.00114489s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'capacity' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryCapacity' AND `sensor_index` = '0']
SQL RUNTIME[0.00054884s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8653' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00028110s]
.] upsSmartBatteryVoltage [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.1638s]
STDOUT[
upsSmartBatteryVoltage.0 = 820
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartBatteryVoltage

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryVoltage']

CMD EXITCODE[0]
CMD RUNTIME[0.027s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.2.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryVoltage' -> '.1.3.6.1.4.1.935.1.1.1.2.2.2'
Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.2.0, index: 0, type: XPPC-MIB-upsSmartBatteryVoltage, descr: Battery Voltage, scale: 1, limits: (, , , ), CURRENT: 820, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryVoltage' AND `sensor_index` = '0')]
SQL RUNTIME[0.00146914s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryVoltage' AND `sensor_index` = '0']
SQL RUNTIME[0.00094509s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8654' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00023603s]
.] upsSmartBatteryCurrent [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryCurrent]

CMD EXITCODE[0]
CMD RUNTIME[0.1574s]
STDOUT[
upsSmartBatteryCurrent.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartBatteryCurrent

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryCurrent']

CMD EXITCODE[0]
CMD RUNTIME[0.0377s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.2.7
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryCurrent' -> '.1.3.6.1.4.1.935.1.1.1.2.2.7'
Excluded by current value (0) is equals or below min (0).
] upsSmartBatteryRunTimeRemaining [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartBatteryRunTimeRemaining]

CMD EXITCODE[0]
CMD RUNTIME[0.1735s]
STDOUT[
upsSmartBatteryRunTimeRemaining.0 = 780
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartBatteryRunTimeRemaining

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartBatteryRunTimeRemaining']

CMD EXITCODE[0]
CMD RUNTIME[0.03s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.2.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartBatteryRunTimeRemaining' -> '.1.3.6.1.4.1.935.1.1.1.2.2.4'
Discover sensor: [class: runtime, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.2.4.0, index: 0, type: XPPC-MIB-upsSmartBatteryRunTimeRemaining, descr: Battery Runtime, scale: 0.016666666666667, limits: (3, 10, , ), CURRENT: 13, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryRunTimeRemaining' AND `sensor_index` = '0')]
SQL RUNTIME[0.00144410s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartBatteryRunTimeRemaining' AND `sensor_index` = '0']
SQL RUNTIME[0.00312901s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '10518' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00032091s]
.] upsSmartInputFrequency [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputFrequency]

CMD EXITCODE[0]
CMD RUNTIME[0.1573s]
STDOUT[
upsSmartInputFrequency.0 = 500
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartInputFrequency

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputFrequency']

CMD EXITCODE[0]
CMD RUNTIME[0.0575s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.3.2.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.3.2.4'
Discover sensor: [class: frequency, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.4.0, index: 0, type: XPPC-MIB-upsSmartInputFrequency, descr: Input Frequency, scale: 0.1, limits: (, , , ), CURRENT: 50, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputFrequency' AND `sensor_index` = '0')]
SQL RUNTIME[0.00223804s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputFrequency' AND `sensor_index` = '0']
SQL RUNTIME[0.00103688s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8655' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00052190s]
.] upsSmartInputLineVoltage [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputLineVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.2032s]
STDOUT[
upsSmartInputLineVoltage.0 = 2231
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartInputLineVoltage

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputLineVoltage']

CMD EXITCODE[0]
CMD RUNTIME[0.049s]
CMD EXITDELAY[10ms]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.3.2.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputLineVoltage' -> '.1.3.6.1.4.1.935.1.1.1.3.2.1'
Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.1.0, index: 0, type: XPPC-MIB-upsSmartInputLineVoltage, descr: Input Voltage, scale: 0.1, limits: (, , , ), CURRENT: 223.1, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputLineVoltage' AND `sensor_index` = '0')]
SQL RUNTIME[0.00372696s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartInputLineVoltage' AND `sensor_index` = '0']
SQL RUNTIME[0.00095105s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8656' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00185204s]
.] upsSmartOutputFrequency [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputFrequency]

CMD EXITCODE[0]
CMD RUNTIME[0.1313s]
STDOUT[
upsSmartOutputFrequency.0 = 500
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartOutputFrequency

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputFrequency']

CMD EXITCODE[0]
CMD RUNTIME[0.0299s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.4.2.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputFrequency' -> '.1.3.6.1.4.1.935.1.1.1.4.2.2'
Discover sensor: [class: frequency, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.2.0, index: 0, type: XPPC-MIB-upsSmartOutputFrequency, descr: Output Frequency, scale: 0.1, limits: (, , , ), CURRENT: 50, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputFrequency' AND `sensor_index` = '0')]
SQL RUNTIME[0.01416492s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputFrequency' AND `sensor_index` = '0']
SQL RUNTIME[0.00142288s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8657' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00042105s]
.] upsSmartOutputVoltage [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputVoltage]

CMD EXITCODE[0]
CMD RUNTIME[0.3081s]
STDOUT[
upsSmartOutputVoltage.0 = 2230
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartOutputVoltage

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputVoltage']

CMD EXITCODE[0]
CMD RUNTIME[0.0882s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.4.2.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputVoltage' -> '.1.3.6.1.4.1.935.1.1.1.4.2.1'
Discover sensor: [class: voltage, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.1.0, index: 0, type: XPPC-MIB-upsSmartOutputVoltage, descr: Output Voltage, scale: 0.1, limits: (, , , ), CURRENT: 223, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputVoltage' AND `sensor_index` = '0')]
SQL RUNTIME[0.00112104s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputVoltage' AND `sensor_index` = '0']
SQL RUNTIME[0.00053000s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8658' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00019813s]
.] upsSmartOutputLoad [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartOutputLoad]

CMD EXITCODE[0]
CMD RUNTIME[0.195s]
STDOUT[
upsSmartOutputLoad.0 = 44
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartOutputLoad

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartOutputLoad']

CMD EXITCODE[0]
CMD RUNTIME[0.0703s]
CMD EXITDELAY[10ms]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.4.2.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartOutputLoad' -> '.1.3.6.1.4.1.935.1.1.1.4.2.3'
Discover sensor: [class: load, device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.2.3.0, index: 0, type: XPPC-MIB-upsSmartOutputLoad, descr: Output Load, scale: 1, limits: (, , 80, 95), CURRENT: 44, ,

SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'load' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputLoad' AND `sensor_index` = '0')]
SQL RUNTIME[0.00940394s]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'load' AND `device_id` = '267' AND `sensor_type` = 'XPPC-MIB-upsSmartOutputLoad' AND `sensor_index` = '0']
SQL RUNTIME[0.00086689s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8659' AND `attrib_type` = 'sensor_addition']
SQL RUNTIME[0.00021219s]
.] upsEnvTemperature [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvTemperature]

CMD EXITCODE[0]
CMD RUNTIME[0.1938s]
STDOUT[
upsEnvTemperature.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvTemperature

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvUnderTemperature.0]

CMD EXITCODE[0]
CMD RUNTIME[0.1626s]
STDOUT[
upsEnvUnderTemperature.0 = 50
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvUnderTemperature.0

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvOverTemperature.0]

CMD EXITCODE[0]
CMD RUNTIME[0.2184s]
STDOUT[
upsEnvOverTemperature.0 = 700
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvOverTemperature.0

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvTemperature']

CMD EXITCODE[0]
CMD RUNTIME[0.1329s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.9.1.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvTemperature' -> '.1.3.6.1.4.1.935.1.1.1.9.1.1'
Excluded by current value (0) is equals or below min (0).
] upsEnvHumidity [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvHumidity]

CMD EXITCODE[0]
CMD RUNTIME[0.2525s]
STDOUT[
upsEnvHumidity.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvHumidity

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvUnderHumidity.0]

CMD EXITCODE[0]
CMD RUNTIME[0.199s]
STDOUT[
upsEnvUnderHumidity.0 = 5
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvUnderHumidity.0

CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvOverHumidity.0]

CMD EXITCODE[0]
CMD RUNTIME[0.229s]
STDOUT[
upsEnvOverHumidity.0 = 90
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvOverHumidity.0

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvHumidity']

CMD EXITCODE[0]
CMD RUNTIME[0.0313s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.9.1.2
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvHumidity' -> '.1.3.6.1.4.1.935.1.1.1.9.1.2'
Excluded by current value (0) is equals or below min (0).
]
 o XPPC-MIB             upsBaseBatteryStatus [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsBaseBatteryStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1575s]
STDOUT[
upsBaseBatteryStatus.0 = batteryNormal
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsBaseBatteryStatus

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsBaseBatteryStatus']

CMD EXITCODE[0]
CMD RUNTIME[0.0763s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.2.1.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsBaseBatteryStatus' -> '.1.3.6.1.4.1.935.1.1.1.2.1.1'
Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.2.1.1.0, index: 0, type: upsBaseBatteryStatus, descr: Battery Status, CURRENT: 2, , battery]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseBatteryStatus' AND `status_type` = 'upsBaseBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00189614s]

SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseBatteryStatus' AND `status_type` = 'upsBaseBatteryStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00067115s]
.] upsSmartInputLineFailCause [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsSmartInputLineFailCause]

CMD EXITCODE[0]
CMD RUNTIME[0.1958s]
STDOUT[
upsSmartInputLineFailCause.0 = noTransfer
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsSmartInputLineFailCause

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsSmartInputLineFailCause']

CMD EXITCODE[0]
CMD RUNTIME[0.0284s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.3.2.5
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsSmartInputLineFailCause' -> '.1.3.6.1.4.1.935.1.1.1.3.2.5'
Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.3.2.5.0, index: 0, type: upsSmartInputLineFailCause, descr: Last Input Fail Cause, CURRENT: 1, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsSmartInputLineFailCause' AND `status_type` = 'upsSmartInputLineFailCause' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00131702s]

SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsSmartInputLineFailCause' AND `status_type` = 'upsSmartInputLineFailCause' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00057292s]
.] upsBaseOutputStatus [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsBaseOutputStatus]

CMD EXITCODE[0]
CMD RUNTIME[0.1774s]
STDOUT[
upsBaseOutputStatus.0 = standBy
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsBaseOutputStatus

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsBaseOutputStatus']

CMD EXITCODE[0]
CMD RUNTIME[0.0285s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.4.1.1
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsBaseOutputStatus' -> '.1.3.6.1.4.1.935.1.1.1.4.1.1'
Discover status: [device: ups-man-f1, oid: .1.3.6.1.4.1.935.1.1.1.4.1.1.0, index: 0, type: upsBaseOutputStatus, descr: Output Status, CURRENT: 8, , other]

SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseOutputStatus' AND `status_type` = 'upsBaseOutputStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')]
SQL RUNTIME[0.00190187s]

SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `status_mib` = 'XPPC-MIB' AND `status_object` = 'upsBaseOutputStatus' AND `status_type` = 'upsBaseOutputStatus' AND `status_index` = '0' AND `poller_type`= 'snmp']
SQL RUNTIME[0.00074506s]
.] upsEnvWater [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvWater]

CMD EXITCODE[0]
CMD RUNTIME[0.1616s]
STDOUT[
upsEnvWater.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvWater

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvWater']

CMD EXITCODE[0]
CMD RUNTIME[0.0276s]
CMD EXITDELAY[10ms]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.9.1.3
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvWater' -> '.1.3.6.1.4.1.935.1.1.1.9.1.3'
Skipped by unknown state value: 0, Sensor Water
] upsEnvSmoke [
CMD[/usr/bin/snmpbulkwalk -v2c -c *** -Pud -Ih -OQUsb -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'udp':'ups-man-f1':'161' upsEnvSmoke]

CMD EXITCODE[0]
CMD RUNTIME[0.1392s]
STDOUT[
upsEnvSmoke.0 = 0
]
SNMP STATUS[TRUE]
Store in cache Table OID: XPPC-MIB::upsEnvSmoke

CMD[/usr/bin/snmptranslate -On -m XPPC-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/megatec 'XPPC-MIB::upsEnvSmoke']

CMD EXITCODE[0]
CMD RUNTIME[0.0493s]
STDOUT[
.1.3.6.1.4.1.935.1.1.1.9.1.4
]
SNMP TRANSLATE (CMD): 'XPPC-MIB::upsEnvSmoke' -> '.1.3.6.1.4.1.935.1.1.1.9.1.4'
Skipped by unknown state value: 0, Sensor Smoke
]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.01301908s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00112987s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00043988s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00031900s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00024796s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00056791s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030589s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00030398s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00023794s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00022602s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00023198s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00023198s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00027490s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029492s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00042892s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00042701s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00130606s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00064397s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00025392s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035501s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00076914s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035810s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00032210s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00031805s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00033402s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00029206s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00022388s]

SQL[SELECT * FROM `sensors` WHERE `device_id` = '267' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0']
SQL RUNTIME[0.00035286s]

SQL[SELECT * FROM `status` WHERE `device_id` = '267' AND `poller_type` = 'snmp' AND `status_deleted` = '0']
SQL RUNTIME[0.00037909s]

SQL[SELECT * FROM `counters` WHERE `device_id` = '267' AND `poller_type` = 'snmp' AND `counter_deleted` = '0']
SQL RUNTIME[0.00029302s]


 o Duration             11.5103s


SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='11.5235',`force_discovery` ='0' WHERE `device_id` = '267']
SQL RUNTIME[0.13439202s]
#####  ups-man-f1 [267] completed discovery modules at 2019-05-23 12:32:29  #####

 o Discovery time       11.5235 seconds


SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '22407' AND `process_name` = 'discovery.php' AND `device_id` = '267']
SQL RUNTIME[0.08766794s]
#####  Finished discovery run at 2019-05-23 12:32:29  #####

./discovery.php: ups-man-f1 - 1 devices discovered in 15.34 secs

SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1558593134']
SQL RUNTIME[0.00081110s]
NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Discovered   1
 o Discovery Time       15.34 secs
 o Memory usage         4MB (peak: 4MB)
 o MySQL Usage          Cell[17/0.175s] Row[25/0.027s] Rows[37/0.181s] Column[1/0.001s] Update[2/0.148s] Insert[1/0.011s] Delete[1/0.088s]