DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0367s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9910 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 9910 Last Changed Date: 2019-05-22 21:59:43 +0200 (Wed, 22 May 2019) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00070500s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00064707s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00073600s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00079489s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 19.5.9910 http://www.observium.org CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.068s] STDOUT[ Linux|3.10.0-693.el7.x86_64|amd64|CentOS|7|vmware| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0049s] STDOUT[ Python 2.7.5 ] SQL[SELECT version();] SQL RUNTIME[0.00077319s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0082s] STDOUT[ NET-SNMP version: 5.7.2 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0118s] STDOUT[ RRDtool 1.6.0 Copyright by Tobias Oetiker ] CMD[/usr/bin/env rrdcached -h -h | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0217s] STDOUT[ RRDCacheD 1.6.0 ] CMD[/usr/bin/env apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0155s] STDOUT[ ] CMD[/usr/sbin/httpd -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0442s] STDOUT[ Apache/2.4.6 ] CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.003s] STDOUT[ +02:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00072694s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00064993s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00223708s] ##### Software versions ##### o OS Linux 3.10.0-693.el7.x86_64 [amd64] (CentOS 7) o Apache 2.4.6 o PHP 7.2.14 (OPcache: DISABLED) o Python 2.7.5 o MySQL 10.1.35-MariaDB (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.2 o RRDtool 1.6.0 (rrdcached 1.6.0: unix:/var/run/rrdcached.sock) o Fping ##### Memory Limit ##### o PHP 4GB ##### MySQL mode ##### o MySQL NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Thursday, 23-May-19 11:12:29 CEST o PHP +02:00 o MySQL +02:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00063205s] REQUEST[http://www.observium.org/versions.php] REQUEST STATUS[TRUE] REQUEST RUNTIME[0.0852s] RESPONSE CODE[200 OK] SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver')] SQL RUNTIME[0.00091696s] SQL[UPDATE `observium_attribs` set `attrib_value` ='19.5.9912' WHERE `attrib_type` = 'latest_ver'] SQL RUNTIME[0.00412893s] SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev')] SQL RUNTIME[0.00155020s] SQL[UPDATE `observium_attribs` set `attrib_value` ='9912' WHERE `attrib_type` = 'latest_rev'] SQL RUNTIME[0.00301385s] SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date')] SQL RUNTIME[0.00123501s] SQL[UPDATE `observium_attribs` set `attrib_value` ='2019-05-23' WHERE `attrib_type` = 'latest_rev_date'] SQL RUNTIME[0.00094819s] SQL[SELECT EXISTS (SELECT 1 FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck')] SQL RUNTIME[0.00134587s] SQL[UPDATE `observium_attribs` set `attrib_value` ='1558602749' WHERE `attrib_type` = 'last_versioncheck'] SQL RUNTIME[0.01190495s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00369096s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00440001s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00086594s] There is a newer revision of Observium available! Version 19.5.9912 (23rd May 2019) is 2 revisions ahead. ##### Starting discovery run at 2019-05-23 11:12:29 ##### SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE '10.14.3.129' AND `status` = '1' AND `poller_id` = '0' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00176477s] CMD[/usr/bin/snmpget -v2c -c *** -Pud -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'10.14.3.129':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0164s] STDOUT[ sysObjectID.0 = enterprises.12148.9 sysUpTime.0 = 0:12:56:09.54 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '687'] SQL RUNTIME[0.00089192s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '687'] SQL RUNTIME[0.00081396s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('12347','discovery.php','10634','1000','php ./discovery.php -d -m sensors -h 10.14.3.129','1558602749','687')] SQL RUNTIME[0.00271201s] ##### 10.14.3.129 [687] ##### o OS Type eltek o SNMP Version v2c o Last discovery 2019-05-23 10:07:08 o Last duration 24.92 seconds ##### Module Start: sensors ##### SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '687' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00076103s] SQL[SELECT `mib` FROM `devices_mibs` WHERE `device_id` = '687' AND `use` = 'mib' AND `disabled` = '1'] SQL RUNTIME[0.00077701s] o ELTEK-DISTRIBUTED-MIB CMD[/usr/bin/snmpget -v2c -c *** -Pud -OUvq -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' .1.3.6.1.4.1.12148.9.6.1.0] CMD EXITCODE[0] CMD RUNTIME[0.0849s] STDOUT[ 235 ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.6.1.0, index: 1, type: eltek-distributed-mib_acVoltage, descr: AC Voltage 1, scale: 1, limits: (, , , ), CURRENT: 235, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '1')] SQL RUNTIME[0.00106907s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '1'] SQL RUNTIME[0.00166106s] LCurrent sensor value: "235", scale: "1" limit_high: "264.5" -> "270.25" limit_high_warn: "" -> "" limit_low: "195.5" -> "199.75" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6435','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"270.25\", limit_low -> \"199.75\"')] SQL RUNTIME[0.00465798s] SQL[UPDATE `sensors` set `sensor_limit` ='270.25',`sensor_limit_low` ='199.75' WHERE `sensor_id` = '6435'] SQL RUNTIME[0.00254393s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6435' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00073504s] . CMD[/usr/bin/snmpget -v2c -c *** -Pud -OUvq -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' .1.3.6.1.4.1.12148.9.6.2.0] CMD EXITCODE[0] CMD RUNTIME[0.087s] STDOUT[ 243 ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.6.2.0, index: 2, type: eltek-distributed-mib_acVoltage, descr: AC Voltage 2, scale: 1, limits: (, , , ), CURRENT: 243, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '2')] SQL RUNTIME[0.00165200s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '2'] SQL RUNTIME[0.00583100s] LCurrent sensor value: "243", scale: "1" limit_high: "272.55" -> "279.45" limit_high_warn: "" -> "" limit_low: "201.45" -> "206.55" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6438','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"279.45\", limit_low -> \"206.55\"')] SQL RUNTIME[0.00466704s] SQL[UPDATE `sensors` set `sensor_limit` ='279.45',`sensor_limit_low` ='206.55' WHERE `sensor_id` = '6438'] SQL RUNTIME[0.02014494s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6438' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00094891s] . CMD[/usr/bin/snmpget -v2c -c *** -Pud -OUvq -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' .1.3.6.1.4.1.12148.9.6.3.0] CMD EXITCODE[0] CMD RUNTIME[0.0831s] STDOUT[ 246 ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.6.3.0, index: 3, type: eltek-distributed-mib_acVoltage, descr: AC Voltage 3, scale: 1, limits: (, , , ), CURRENT: 246, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '3')] SQL RUNTIME[0.00103092s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_acVoltage' AND `sensor_index` = '3'] SQL RUNTIME[0.00110292s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6441' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00073719s] . CMD[/usr/bin/snmpwalk -v2c -c *** -Pud -OQUs -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' rectifierStatusTable] CMD EXITCODE[0] CMD RUNTIME[16.4854s] STDOUT[ rectifierStatusID.0 = 1 rectifierStatusID.1 = 2 rectifierStatusID.2 = 3 rectifierStatusID.3 = 4 rectifierStatusID.4 = 5 rectifierStatusID.5 = 6 rectifierStatusID.6 = 7 rectifierStatusID.7 = 8 rectifierStatusID.8 = 9 rectifierStatusID.9 = 10 rectifierStatusID.10 = 11 rectifierStatusID.11 = 12 rectifierStatusID.12 = 13 rectifierStatusID.13 = 14 rectifierStatusID.14 = 15 rectifierStatusID.15 = 16 rectifierStatusID.16 = 17 rectifierStatusID.17 = 18 rectifierStatusID.18 = 19 rectifierStatusID.19 = 20 rectifierStatusStatus.0 = normal rectifierStatusStatus.1 = normal rectifierStatusStatus.2 = normal rectifierStatusStatus.3 = normal rectifierStatusStatus.4 = notPresent rectifierStatusStatus.5 = notPresent rectifierStatusStatus.6 = notPresent rectifierStatusStatus.7 = notPresent rectifierStatusStatus.8 = notPresent rectifierStatusStatus.9 = notPresent rectifierStatusStatus.10 = notPresent rectifierStatusStatus.11 = notPresent rectifierStatusStatus.12 = notPresent rectifierStatusStatus.13 = notPresent rectifierStatusStatus.14 = notPresent rectifierStatusStatus.15 = notPresent rectifierStatusStatus.16 = notPresent rectifierStatusStatus.17 = notPresent rectifierStatusStatus.18 = notPresent rectifierStatusStatus.19 = notPresent rectifierStatusOutputCurrent.0 = 20 rectifierStatusOutputCurrent.1 = 21 rectifierStatusOutputCurrent.2 = 22 rectifierStatusOutputCurrent.3 = 22 rectifierStatusOutputCurrent.4 = 0 rectifierStatusOutputCurrent.5 = 0 rectifierStatusOutputCurrent.6 = 0 rectifierStatusOutputCurrent.7 = 0 rectifierStatusOutputCurrent.8 = 0 rectifierStatusOutputCurrent.9 = 0 rectifierStatusOutputCurrent.10 = 0 rectifierStatusOutputCurrent.11 = 0 rectifierStatusOutputCurrent.12 = 0 rectifierStatusOutputCurrent.13 = 0 rectifierStatusOutputCurrent.14 = 0 rectifierStatusOutputCurrent.15 = 0 rectifierStatusOutputCurrent.16 = 0 rectifierStatusOutputCurrent.17 = 0 rectifierStatusOutputCurrent.18 = 0 rectifierStatusOutputCurrent.19 = 0 rectifierStatusOutputVoltage.0 = 5373 rectifierStatusOutputVoltage.1 = 5376 rectifierStatusOutputVoltage.2 = 5382 rectifierStatusOutputVoltage.3 = 5369 rectifierStatusOutputVoltage.4 = 0 rectifierStatusOutputVoltage.5 = 0 rectifierStatusOutputVoltage.6 = 0 rectifierStatusOutputVoltage.7 = 0 rectifierStatusOutputVoltage.8 = 0 rectifierStatusOutputVoltage.9 = 0 rectifierStatusOutputVoltage.10 = 0 rectifierStatusOutputVoltage.11 = 0 rectifierStatusOutputVoltage.12 = 0 rectifierStatusOutputVoltage.13 = 0 rectifierStatusOutputVoltage.14 = 0 rectifierStatusOutputVoltage.15 = 0 rectifierStatusOutputVoltage.16 = 0 rectifierStatusOutputVoltage.17 = 0 rectifierStatusOutputVoltage.18 = 0 rectifierStatusOutputVoltage.19 = 0 rectifierStatusTemp.0 = 34 rectifierStatusTemp.1 = 33 rectifierStatusTemp.2 = 34 rectifierStatusTemp.3 = 34 rectifierStatusTemp.4 = 0 rectifierStatusTemp.5 = 0 rectifierStatusTemp.6 = 0 rectifierStatusTemp.7 = 0 rectifierStatusTemp.8 = 0 rectifierStatusTemp.9 = 0 rectifierStatusTemp.10 = 0 rectifierStatusTemp.11 = 0 rectifierStatusTemp.12 = 0 rectifierStatusTemp.13 = 0 rectifierStatusTemp.14 = 0 rectifierStatusTemp.15 = 0 rectifierStatusTemp.16 = 0 rectifierStatusTemp.17 = 0 rectifierStatusTemp.18 = 0 rectifierStatusTemp.19 = 0 rectifierStatusType.0 = MINIPACK 48/800 WI rectifierStatusType.1 = MINIPACK 48/800 WI rectifierStatusType.2 = MINIPACK 48/800 WI rectifierStatusType.3 = MINIPACK 48/800 WI rectifierStatusType.4 = - rectifierStatusType.5 = - rectifierStatusType.6 = - rectifierStatusType.7 = - rectifierStatusType.8 = - rectifierStatusType.9 = - rectifierStatusType.10 = - rectifierStatusType.11 = - rectifierStatusType.12 = - rectifierStatusType.13 = - rectifierStatusType.14 = - rectifierStatusType.15 = - rectifierStatusType.16 = - rectifierStatusType.17 = - rectifierStatusType.18 = - rectifierStatusType.19 = - rectifierStatusSKU.0 = 241117.130 rectifierStatusSKU.1 = 241117.130 rectifierStatusSKU.2 = 241117.130 rectifierStatusSKU.3 = 241117.130 rectifierStatusSKU.4 = - rectifierStatusSKU.5 = - rectifierStatusSKU.6 = - rectifierStatusSKU.7 = - rectifierStatusSKU.8 = - rectifierStatusSKU.9 = - rectifierStatusSKU.10 = - rectifierStatusSKU.11 = - rectifierStatusSKU.12 = - rectifierStatusSKU.13 = - rectifierStatusSKU.14 = - rectifierStatusSKU.15 = - rectifierStatusSKU.16 = - rectifierStatusSKU.17 = - rectifierStatusSKU.18 = - rectifierStatusSKU.19 = - rectifierStatusSerialNo.0 = 133871114068 rectifierStatusSerialNo.1 = 135271120388 rectifierStatusSerialNo.2 = 135271120376 rectifierStatusSerialNo.3 = 133471128544 rectifierStatusSerialNo.4 = - rectifierStatusSerialNo.5 = - rectifierStatusSerialNo.6 = - rectifierStatusSerialNo.7 = - rectifierStatusSerialNo.8 = - rectifierStatusSerialNo.9 = - rectifierStatusSerialNo.10 = - rectifierStatusSerialNo.11 = - rectifierStatusSerialNo.12 = - rectifierStatusSerialNo.13 = - rectifierStatusSerialNo.14 = - rectifierStatusSerialNo.15 = - rectifierStatusSerialNo.16 = - rectifierStatusSerialNo.17 = - rectifierStatusSerialNo.18 = - rectifierStatusSerialNo.19 = - rectifierStatusRevisionLevel.0 = 1.5 rectifierStatusRevisionLevel.1 = 1.5 rectifierStatusRevisionLevel.2 = 1.5 rectifierStatusRevisionLevel.3 = 1.5 rectifierStatusRevisionLevel.4 = - rectifierStatusRevisionLevel.5 = - rectifierStatusRevisionLevel.6 = - rectifierStatusRevisionLevel.7 = - rectifierStatusRevisionLevel.8 = - rectifierStatusRevisionLevel.9 = - rectifierStatusRevisionLevel.10 = - rectifierStatusRevisionLevel.11 = - rectifierStatusRevisionLevel.12 = - rectifierStatusRevisionLevel.13 = - rectifierStatusRevisionLevel.14 = - rectifierStatusRevisionLevel.15 = - rectifierStatusRevisionLevel.16 = - rectifierStatusRevisionLevel.17 = - rectifierStatusRevisionLevel.18 = - rectifierStatusRevisionLevel.19 = - ] SNMP STATUS[TRUE] Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.4.0, index: 0, type: eltek-distributed-mib_rectifierStatusOutputVoltage, descr: Rectifier 1 (MINIPACK 48/800 WI), scale: 0.01, limits: (, , , ), CURRENT: 53.73, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00111198s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00107479s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6444' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00093818s] .Discover sensor: [class: current, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.3.0, index: 0, type: eltek-distributed-mib_rectifierStatusOutputCurrent, descr: Rectifier 1 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 20, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '0')] SQL RUNTIME[0.00178599s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '0'] SQL RUNTIME[0.00107622s] LCurrent sensor value: "20", scale: "1" limit_high: "33" -> "30" limit_high_warn: "" -> "" limit_low: "" -> "" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6447','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"30\"')] SQL RUNTIME[0.00297189s] SQL[UPDATE `sensors` set `sensor_limit` ='30' WHERE `sensor_id` = '6447'] SQL RUNTIME[0.00393510s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6447' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00092697s] .Discover sensor: [class: temperature, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.5.0, index: 0, type: eltek-distributed-mib_rectifierStatusTemp, descr: Rectifier 1 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 34, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '0')] SQL RUNTIME[0.00095201s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '0'] SQL RUNTIME[0.00120401s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6450' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00086212s] .Discover status: [device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.2.0, index: rectifierStatusStatus.0, type: eltek-distributed-mib_rectifierStatusStatus, descr: Rectifier 1 (MINIPACK 48/800 WI), CURRENT: 1, , ] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00093389s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00091696s] .Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.4.1, index: 1, type: eltek-distributed-mib_rectifierStatusOutputVoltage, descr: Rectifier 2 (MINIPACK 48/800 WI), scale: 0.01, limits: (, , , ), CURRENT: 53.76, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '1')] SQL RUNTIME[0.00090289s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '1'] SQL RUNTIME[0.00117302s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6453' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00082898s] .Discover sensor: [class: current, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.3.1, index: 1, type: eltek-distributed-mib_rectifierStatusOutputCurrent, descr: Rectifier 2 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 21, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '1')] SQL RUNTIME[0.00094199s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '1'] SQL RUNTIME[0.00105190s] LCurrent sensor value: "21", scale: "1" limit_high: "28.5" -> "31.5" limit_high_warn: "" -> "" limit_low: "" -> "" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6456','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"31.5\"')] SQL RUNTIME[0.00330901s] SQL[UPDATE `sensors` set `sensor_limit` ='31.5' WHERE `sensor_id` = '6456'] SQL RUNTIME[0.00270605s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6456' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00088596s] .Discover sensor: [class: temperature, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.5.1, index: 1, type: eltek-distributed-mib_rectifierStatusTemp, descr: Rectifier 2 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 33, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '1')] SQL RUNTIME[0.00101614s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '1'] SQL RUNTIME[0.00101590s] LCurrent sensor value: "33", scale: "1" limit_high: "54.4" -> "52.8" limit_high_warn: "" -> "" limit_low: "0" -> "0" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6459','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"52.8\"')] SQL RUNTIME[0.00254083s] SQL[UPDATE `sensors` set `sensor_limit` ='52.8' WHERE `sensor_id` = '6459'] SQL RUNTIME[0.00303507s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6459' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00101995s] .Discover status: [device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.2.1, index: rectifierStatusStatus.1, type: eltek-distributed-mib_rectifierStatusStatus, descr: Rectifier 2 (MINIPACK 48/800 WI), CURRENT: 1, , ] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.1' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00081205s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00102210s] .Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.4.2, index: 2, type: eltek-distributed-mib_rectifierStatusOutputVoltage, descr: Rectifier 3 (MINIPACK 48/800 WI), scale: 0.01, limits: (, , , ), CURRENT: 53.82, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '2')] SQL RUNTIME[0.00101614s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '2'] SQL RUNTIME[0.00188112s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6462' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00094795s] .Discover sensor: [class: current, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.3.2, index: 2, type: eltek-distributed-mib_rectifierStatusOutputCurrent, descr: Rectifier 3 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 22, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '2')] SQL RUNTIME[0.00076294s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '2'] SQL RUNTIME[0.00270796s] LCurrent sensor value: "22", scale: "1" limit_high: "34.5" -> "33" limit_high_warn: "" -> "" limit_low: "" -> "" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6465','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"33\"')] SQL RUNTIME[0.00344300s] SQL[UPDATE `sensors` set `sensor_limit` ='33' WHERE `sensor_id` = '6465'] SQL RUNTIME[0.00515819s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6465' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00108504s] .Discover sensor: [class: temperature, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.5.2, index: 2, type: eltek-distributed-mib_rectifierStatusTemp, descr: Rectifier 3 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 34, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '2')] SQL RUNTIME[0.00100899s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '2'] SQL RUNTIME[0.00098085s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6468' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00076008s] .Discover status: [device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.2.2, index: rectifierStatusStatus.2, type: eltek-distributed-mib_rectifierStatusStatus, descr: Rectifier 3 (MINIPACK 48/800 WI), CURRENT: 1, , ] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.2' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00081205s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.2' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00101113s] .Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.4.3, index: 3, type: eltek-distributed-mib_rectifierStatusOutputVoltage, descr: Rectifier 4 (MINIPACK 48/800 WI), scale: 0.01, limits: (, , , ), CURRENT: 53.69, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '3')] SQL RUNTIME[0.00183201s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputVoltage' AND `sensor_index` = '3'] SQL RUNTIME[0.00122309s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6471' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00080991s] .Discover sensor: [class: current, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.3.3, index: 3, type: eltek-distributed-mib_rectifierStatusOutputCurrent, descr: Rectifier 4 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 22, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '3')] SQL RUNTIME[0.00097704s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusOutputCurrent' AND `sensor_index` = '3'] SQL RUNTIME[0.00117111s] LCurrent sensor value: "22", scale: "1" limit_high: "31.5" -> "33" limit_high_warn: "" -> "" limit_low: "" -> "" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6474','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"33\"')] SQL RUNTIME[0.00613999s] SQL[UPDATE `sensors` set `sensor_limit` ='33' WHERE `sensor_id` = '6474'] SQL RUNTIME[0.00320292s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6474' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00138283s] .Discover sensor: [class: temperature, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.5.3, index: 3, type: eltek-distributed-mib_rectifierStatusTemp, descr: Rectifier 4 (MINIPACK 48/800 WI), scale: 1, limits: (, , , ), CURRENT: 34, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '3')] SQL RUNTIME[0.00526023s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'eltek-distributed-mib_rectifierStatusTemp' AND `sensor_index` = '3'] SQL RUNTIME[0.00149393s] LCurrent sensor value: "34", scale: "1" limit_high: "56" -> "54.4" limit_high_warn: "" -> "" limit_low: "0" -> "0" limit_low_warn: "" -> "" SQL[INSERT INTO `eventlog` (`device_id`,`entity_id`,`entity_type`,`timestamp`,`severity`,`message`) VALUES ('687','6477','sensor',NOW(),'6','Sensor updated (limits): limit_high -> \"54.4\"')] SQL RUNTIME[0.00424409s] SQL[UPDATE `sensors` set `sensor_limit` ='54.4' WHERE `sensor_id` = '6477'] SQL RUNTIME[0.01029110s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6477' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00211906s] .Discover status: [device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.5.5.2.1.2.3, index: rectifierStatusStatus.3, type: eltek-distributed-mib_rectifierStatusStatus, descr: Rectifier 4 (MINIPACK 48/800 WI), CURRENT: 1, , ] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.3' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00112295s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `status_type` = 'eltek-distributed-mib_rectifierStatusStatus' AND `status_index` = 'rectifierStatusStatus.3' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00108194s] . o ELTEK-DISTRIBUTED-MIB batteryVoltage [ CMD[/usr/bin/snmpwalk -v2c -c *** -Pud -Ih -OQUsb -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' batteryVoltage] CMD EXITCODE[0] CMD RUNTIME[0.1565s] STDOUT[ batteryVoltage.0 = 5374 ] SNMP STATUS[TRUE] Store in cache Table OID: ELTEK-DISTRIBUTED-MIB::batteryVoltage Discover sensor: [class: voltage, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.3.2.0, index: 0, type: ELTEK-DISTRIBUTED-MIB-batteryVoltage, descr: Battery Voltage, scale: 0.01, limits: (, , , ), CURRENT: 53.74, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryVoltage' AND `sensor_index` = '0')] SQL RUNTIME[0.00127697s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryVoltage' AND `sensor_index` = '0'] SQL RUNTIME[0.00120616s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6480' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00078988s] .] batteryCurrent [ CMD[/usr/bin/snmpwalk -v2c -c *** -Pud -Ih -OQUsb -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' batteryCurrent] CMD EXITCODE[0] CMD RUNTIME[0.1431s] STDOUT[ batteryCurrent.0 = 5 ] SNMP STATUS[TRUE] Store in cache Table OID: ELTEK-DISTRIBUTED-MIB::batteryCurrent Discover sensor: [class: current, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.3.3.0, index: 0, type: ELTEK-DISTRIBUTED-MIB-batteryCurrent, descr: Battery Current, scale: 1, limits: (, , , ), CURRENT: 5, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryCurrent' AND `sensor_index` = '0')] SQL RUNTIME[0.00133705s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryCurrent' AND `sensor_index` = '0'] SQL RUNTIME[0.00115204s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6483' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00070190s] .] batteryTemp [ CMD[/usr/bin/snmpwalk -v2c -c *** -Pud -Ih -OQUsb -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' batteryTemp] CMD EXITCODE[0] CMD RUNTIME[0.1437s] STDOUT[ batteryTemp.0 = 35 ] SNMP STATUS[TRUE] Store in cache Table OID: ELTEK-DISTRIBUTED-MIB::batteryTemp Discover sensor: [class: temperature, device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.3.4.0, index: 0, type: ELTEK-DISTRIBUTED-MIB-batteryTemp, descr: Battery Temperature, scale: 1, limits: (, , , ), CURRENT: 35, , SQL[SELECT EXISTS (SELECT 1 FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryTemp' AND `sensor_index` = '0')] SQL RUNTIME[0.00125599s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '687' AND `sensor_type` = 'ELTEK-DISTRIBUTED-MIB-batteryTemp' AND `sensor_index` = '0'] SQL RUNTIME[0.00112104s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6486' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00077987s] .] o ELTEK-DISTRIBUTED-MIB batteryBreakerStatus [ CMD[/usr/bin/snmpwalk -v2c -c *** -Pud -Ih -OQUsb -m ELTEK-DISTRIBUTED-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/eltek 'udp':'10.14.3.129':'161' batteryBreakerStatus] CMD EXITCODE[0] CMD RUNTIME[0.2441s] STDOUT[ batteryBreakerStatus.0 = normal ] SNMP STATUS[TRUE] Store in cache Table OID: ELTEK-DISTRIBUTED-MIB::batteryBreakerStatus Discover status: [device: 10.14.3.129, oid: .1.3.6.1.4.1.12148.9.3.5.0, index: 0, type: batteryBreakerStatus, descr: Battery Breaker Status, CURRENT: 0, , battery] SQL[SELECT EXISTS (SELECT 1 FROM `status` WHERE `device_id` = '687' AND `status_mib` = 'ELTEK-DISTRIBUTED-MIB' AND `status_object` = 'batteryBreakerStatus' AND `status_type` = 'batteryBreakerStatus' AND `status_index` = '0' AND `poller_type`= 'snmp')] SQL RUNTIME[0.00119901s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `status_mib` = 'ELTEK-DISTRIBUTED-MIB' AND `status_object` = 'batteryBreakerStatus' AND `status_type` = 'batteryBreakerStatus' AND `status_index` = '0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00095582s] .] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00113702s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00106788s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00106502s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00090885s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00082898s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00094700s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00087118s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00086093s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00091314s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00085998s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00085711s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00085592s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00088906s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00089288s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00098205s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00108409s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00082493s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00117707s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00087595s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00089812s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00092602s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00112414s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00091910s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00094199s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00091100s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096083s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00083399s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '687' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00094604s] SQL[SELECT * FROM `status` WHERE `device_id` = '687' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00084305s] SQL[SELECT * FROM `counters` WHERE `device_id` = '687' AND `poller_type` = 'snmp' AND `counter_deleted` = '0'] SQL RUNTIME[0.00081205s] o Duration 17.6683s SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='power',`last_discovered_timetaken` ='17.6731',`force_discovery` ='0' WHERE `device_id` = '687'] SQL RUNTIME[0.05432200s] ##### 10.14.3.129 [687] completed discovery modules at 2019-05-23 11:12:47 ##### o Discovery time 17.6731 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '12347' AND `process_name` = 'discovery.php' AND `device_id` = '687'] SQL RUNTIME[0.00325203s] ##### Finished discovery run at 2019-05-23 11:12:47 ##### ./discovery.php: 10.14.3.129 - 1 devices discovered in 18.08 secs Log file '/opt/observium/logs/observium.log' is not writable, check file permissions. SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1558588349'] SQL RUNTIME[0.00085092s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Discovered 1 o Discovery Time 18.08 secs o Memory usage 14MB (peak: 14MB) o MySQL Usage Cell[31/0.044s] Row[48/0.071s] Rows[37/0.044s] Column[1/0.001s] Update[13/0.128s] Insert[9/0.036s] Delete[1/0.003s] o RRDTool Usage