CMD[/usr/bin/svn info /opt/observium]

CMD EXITCODE[0]
CMD RUNTIME[0.0065s]
STDOUT[
Path: .
Working Copy Root Path: /opt/observium
URL: http://svn.observium.org/svn/observium/trunk
Relative URL: ^/observium/trunk
Repository Root: http://svn.observium.org/svn
Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8
Revision: 9785
Node Kind: directory
Schedule: normal
Last Changed Author: mike
Last Changed Rev: 9785
Last Changed Date: 2019-03-25 23:09:57 +0100 (Mon, 25 Mar 2019)

]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';]
SQL RUNTIME[0.00030708s]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00013709s]

SQL[SET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION']
SQL RUNTIME[0.00010204s]
DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';]
SQL RUNTIME[0.00013709s]

SQL[SELECT * FROM `config`]
SQL RUNTIME[0.00020981s]

CMD[/bin/hostname -f]

CMD EXITCODE[0]
CMD RUNTIME[0.001s]
STDOUT[
sat-nms01
]

  ___   _                              _
 / _ \ | |__   ___   ___  _ __ __   __(_) _   _  _ __ ___
| | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \
| |_| || |_) |\__ \|  __/| |    \ V / | || |_| || | | | | |
 \___/ |_.__/ |___/ \___||_|     \_/  |_| \__,_||_| |_| |_|
                           Observium Professional 19.3.9785
                                   http://www.observium.org


SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';]
SQL RUNTIME[0.00020719s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';]
SQL RUNTIME[0.00013089s]

SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';]
SQL RUNTIME[0.00014806s]
There is a newer revision of Observium available!

CMD[date "+%:z"]

CMD EXITCODE[0]
CMD RUNTIME[0.0007s]
CMD EXITDELAY[10ms]
STDOUT[
+01:00
]

SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);]
SQL RUNTIME[0.00026202s]
Version 19.3.9786 (26th March 2019) is 1 revisions ahead.


CMD[/opt/observium/scripts/distro]

CMD EXITCODE[0]
CMD RUNTIME[0.0067s]
STDOUT[
Linux|4.4.0-142-generic|amd64|Ubuntu|16.04|vmware|
]

CMD[/usr/bin/env python --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0014s]
STDOUT[
Python 2.7.12
]

SQL[SELECT version();]
SQL RUNTIME[0.00011086s]

CMD[/usr/bin/snmpget --version 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0013s]
STDOUT[
NET-SNMP version: 5.7.3
]

CMD[/usr/bin/rrdtool --version | head -n1]

CMD EXITCODE[0]
CMD RUNTIME[0.0053s]
STDOUT[
RRDtool 1.5.5  Copyright by Tobias Oetiker <tobi@oetiker.ch>
]

CMD[/usr/bin/fping -v 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0011s]
STDOUT[
/usr/bin/fping: Version 3.13
/usr/bin/fping: comments to david@schweikert.ch
]

CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}']

CMD EXITCODE[0]
CMD RUNTIME[0.0324s]
STDOUT[
Apache/2.4.18
]

SQL[SELECT @@SESSION.sql_mode;]
SQL RUNTIME[0.00024891s]

SQL[SHOW VARIABLES LIKE 'character_set_connection']
SQL RUNTIME[0.00163388s]

#####  Software versions  #####

 o OS                   Linux 4.4.0-142-generic [amd64] (Ubuntu 16.04)
 o Apache               2.4.18
 o PHP                  7.0.33-0ubuntu0.16.04.2 (OPcache: ENABLED)
 o Python               2.7.12
 o MySQL                5.7.25-0ubuntu0.16.04.2 (extension: mysqli 5.0.12-dev)
 o SNMP                 NET-SNMP 5.7.3
 o RRDtool              1.5.5
 o Fping                3.13 (IPv4 and IPv6)

#####  Memory Limit  #####

 o PHP                  Unlimited

#####  MySQL mode  #####

 o MySQL                NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION

#####  Charset info  #####

 o PHP                  UTF-8
 o MySQL                utf8

#####  Timezones info  #####

 o Date                 Tuesday, 26-Mar-19 22:27:39 CET
 o PHP                  +01:00
 o MySQL                +01:00


SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1553635659' AND `maint_end` > '1553635659']
SQL RUNTIME[0.00043392s]
#####  Starting polling run at 2019-03-26 22:27:39  #####


SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'router' AND `poller_id` = '0' ORDER BY `device_id` ASC]
SQL RUNTIME[0.00051308s]

SQL[SELECT * FROM `devices` WHERE `device_id` = '39']
SQL RUNTIME[0.00043607s]

SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39']
SQL RUNTIME[0.00045514s]

SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '39']
SQL RUNTIME[0.00029111s]

SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`)  VALUES ('27088','poller.php','5746','0','php ./poller.php -d -m sensors -h router','1553635659','39')]
SQL RUNTIME[0.00814009s]

SQL[SELECT * FROM `alert_tests` WHERE 1]
SQL RUNTIME[0.00038910s]
Cached 15 alert rules.

SQL[SELECT * FROM  `alert_table` WHERE `device_id` = '39']
SQL RUNTIME[0.00119400s]
#####  router [39]  #####

 o OS                   hh3c
 o Last poll duration   7.52 seconds
 o Last Polled          2019-03-26 22:25:19
 o SNMP Version         v2c

CMD[/usr/bin/fping -t 500 -c 1 -q 10.254.196.15 2>&1]

CMD EXITCODE[0]
CMD RUNTIME[0.0137s]
STDOUT[
10.254.196.15 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 12.6/12.6/12.6
]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysObjectID.0 sysUpTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0227s]
STDOUT[
sysObjectID.0 = enterprises.25506.11.1.20
sysUpTime.0 = 295:1:53:10.25
]
SNMP STATUS[TRUE]
 o Device status        Device is reachable by PING (12.6ms) and SNMP (22.67ms)
RRD /opt/observium/rrd/router/status.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/status.rrd N:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.05]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/router/ping.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/ping.rrd N:12.6]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.05]
RRD_STATUS[TRUE]

RRD /opt/observium/rrd/router/ping_snmp.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/ping_snmp.rrd N:22.67]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.05]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '39']
SQL RUNTIME[0.00041199s]
 o Modules Enabled      system, os, sensors


including: includes/polling/system.inc.php
#####  Module Start: system  #####


SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00018787s]

SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39' AND `attrib_type` = 'sysORID']
SQL RUNTIME[0.00014591s]

SQL[SELECT * FROM `observium_attribs`]
SQL RUNTIME[0.00012207s]
 o SNMPv2-MIB
CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0197s]
STDOUT[
sysUpTime.0 = 295:1:53:10.28
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysDescr.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0189s]
STDOUT[
HP Comware Platform Software, Software Version 5.20.105, Release 1808P21
HP A5800-24G-SFP Switch with 1 Interface Slot
Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P.
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysObjectID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.023s]
STDOUT[
.1.3.6.1.4.1.25506.11.1.20
]
SNMP STATUS[TRUE]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' snmpEngineID.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0219s]
STDOUT[
"80 00 00 0B 03 CC 3E 5F A1 F7 AB "
]
SNMP STATUS[TRUE]


CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' hrSystemUptime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0203s]
STDOUT[
No Such Object available on this agent at this OID
]
SNMP STATUS[FALSE]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemUptime.0';]
SQL RUNTIME[0.00060797s]

SQL[UPDATE `snmp_errors` set `error_count` ='94065',`updated` ='1553635659' WHERE `error_id` = '337']
SQL RUNTIME[0.00196290s]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' snmpEngineTime.0]

CMD EXITCODE[0]
CMD RUNTIME[0.0186s]
STDOUT[
154343772
]
SNMP STATUS[TRUE]
Using SNMP Agent snmpEngineTime (154343772 sec. => 4 years, 326 days, 9h 16m 12s)
RRD /opt/observium/rrd/router/uptime.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/uptime.rrd N:154343772]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.19]
RRD_STATUS[TRUE]

 o Uptime               4 years, 326 days, 9h 16m 12s
 o Last reboot          2014-05-05 12:09:09


  /opt/observium/includes/polling/system.inc.php:286
array(
  [use]            => string(14) "snmpEngineTime"
  [sysUpTime]      => int(25494790)
  [hrSystemUptime] => bool(false)
  [snmpEngineTime] => int(154343772)
  [uptime]         => int(154343772)
  [formatted]      => string(29) "4 years, 326 days, 9h 16m 12s"
  [message]        => string(31) "Using SNMP Agent snmpEngineTime"
  [previous]       => string(9) "154343624"
  [diff]           => int(-148)
  [last_rebooted]  => string(10) "1399291749"
  [rebooted]       => int(0)
)

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3]

CMD EXITCODE[0]
CMD RUNTIME[0.0193s]
STDOUT[
.1.3.6.1.4.1.2021.10.1.5.1 = No Such Object available on this agent at this OID
.1.3.6.1.4.1.2021.10.1.5.2 = No Such Object available on this agent at this OID
.1.3.6.1.4.1.2021.10.1.5.3 = No Such Object available on this agent at this OID
]
SNMP ERROR[#1000 - Failed response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';]
SQL RUNTIME[0.00037122s]

SQL[UPDATE `snmp_errors` set `error_count` ='88128',`updated` ='1553635659' WHERE `error_id` = '2952']
SQL RUNTIME[0.00501990s]
SNMP STATUS[FALSE]
 o sysObjectID          .1.3.6.1.4.1.25506.11.1.20
 o snmpEngineID         8000000B03CC3E5FA1F7AB
 o sysDescr             HP Comware Platform Software, Software Version 5.20.105, Release 1808P21
                        HP A5800-24G-SFP Switch with 1 Interface Slot
                        Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P.
 o sysName              router
 o Location             Address

SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '39']
SQL RUNTIME[0.00034809s]
 o Module time          0.1642s


including: includes/polling/os.inc.php
#####  Module Start: os  #####


SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '39' AND `entPhysicalContainedIn` = '0' AND `deleted` IS NULL]
SQL RUNTIME[0.00046515s]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m HH3C-ENTITY-EXT-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/hh3c 'udp':'router':'161' hh3cEntityExtManuSerialNum.1]

CMD EXITCODE[0]
CMD RUNTIME[0.0222s]
STDOUT[

]
SNMP STATUS[FALSE]
SNMP ERROR[#1 - Empty response]

SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HH3C-ENTITY-EXT-MIB' AND `oid` = 'hh3cEntityExtManuSerialNum.1';]
SQL RUNTIME[0.00028014s]

SQL[UPDATE `snmp_errors` set `error_count` ='94065',`updated` ='1553635659' WHERE `error_id` = '338']
SQL RUNTIME[0.00138402s]
 o OS Poller            OS
 o Vendor               HPE
 o Hardware             HP A5800-24G-SFP Switch with 1 Interface Slot
 o Version              5.20.105 1808P21
 o Features             <empty>
 o Serial               <empty>
 o Asset                <empty>

 o Module time          0.0288s


including: includes/polling/sensors.inc.php
#####  Module Start: sensors  #####


SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '39' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','charge','power','energy','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','snr','dust','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','illuminance','wavelength','counter')]
SQL RUNTIME[0.00065708s]

SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '39' AND `entity_type` IN ('sensor')]
SQL RUNTIME[0.00020313s]

SQL[SELECT `sensor_oid` FROM `sensors` WHERE `device_id` = '39' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00023293s]

CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262 1.3.6.1.4.1.25506.2.70.1.1.1.9.28 1.3.6.1.4.1.25506.2.70.1.1.1.12.28 1.3.6.1.4.1.25506.2.70.1.1.1.15.28 1.3.6.1.4.1.25506.2.70.1.1.1.16.28 1.3.6.1.4.1.25506.2.70.1.1.1.17.28]

CMD EXITCODE[0]
CMD RUNTIME[0.0379s]
STDOUT[
.1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112 = 39
.1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118 = 39
.1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262 = 39
.1.3.6.1.4.1.25506.2.70.1.1.1.9.28 = -179
.1.3.6.1.4.1.25506.2.70.1.1.1.12.28 = -192
.1.3.6.1.4.1.25506.2.70.1.1.1.15.28 = 33
.1.3.6.1.4.1.25506.2.70.1.1.1.16.28 = 329
.1.3.6.1.4.1.25506.2.70.1.1.1.17.28 = 2816
]
SNMP STATUS[TRUE]

SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00042415s]
Checking (snmp) temperature Board

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3600"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(11) "temperature"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112"
  [sensor_mib]                => string(19) "HH3C-ENTITY-EXT-MIB"
  [sensor_object]             => string(24) "hh3cEntityExtTemperature"
  [sensor_index]              => string(3) "112"
  [sensor_type]               => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature"
  [sensor_descr]              => string(5) "Board"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => string(4) "62.4"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "39.00000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(39)
)
RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-112.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-112.rrd N:39]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.29]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30595']
SQL RUNTIME[0.00151205s]
RRD /opt/observium/rrd/router/alert-30595.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30595.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.29]
RRD_STATUS[TRUE]

Checking (snmp) temperature SENSOR 1

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3601"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(11) "temperature"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118"
  [sensor_mib]                => string(19) "HH3C-ENTITY-EXT-MIB"
  [sensor_object]             => string(24) "hh3cEntityExtTemperature"
  [sensor_index]              => string(3) "118"
  [sensor_type]               => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature"
  [sensor_descr]              => string(8) "SENSOR 1"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => string(2) "75"
  [sensor_limit_warn]         => string(2) "65"
  [sensor_limit_low]          => string(1) "5"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "39.00000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(39)
)
RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-118.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-118.rrd N:39]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.29]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30596']
SQL RUNTIME[0.00129604s]
RRD /opt/observium/rrd/router/alert-30596.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30596.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.29]
RRD_STATUS[TRUE]

Checking (snmp) temperature SubCard0

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3602"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(11) "temperature"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262"
  [sensor_mib]                => string(19) "HH3C-ENTITY-EXT-MIB"
  [sensor_object]             => string(24) "hh3cEntityExtTemperature"
  [sensor_index]              => string(3) "262"
  [sensor_type]               => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature"
  [sensor_descr]              => string(8) "SubCard0"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => string(4) "62.4"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => null
  [measured_entity]           => null
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "39.00000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(39)
)
RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-262.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-262.rrd N:39]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.30]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30597']
SQL RUNTIME[0.00270796s]
RRD /opt/observium/rrd/router/alert-30597.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30597.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.30]
RRD_STATUS[TRUE]

Checking (snmp) temperature Ten-GigabitEthernet1/0/26 Temperature

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3603"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(11) "temperature"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.15.28"
  [sensor_mib]                => string(25) "HH3C-TRANSCEIVER-INFO-MIB"
  [sensor_object]             => string(26) "hh3cTransceiverTemperature"
  [sensor_index]              => string(2) "28"
  [sensor_type]               => string(52) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature"
  [sensor_descr]              => string(37) "Ten-GigabitEthernet1/0/26 Temperature"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(1) "1"
  [sensor_limit]              => string(4) "51.2"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => string(4) "port"
  [measured_entity]           => string(4) "3987"
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "33.00000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(33)
)
RRD /opt/observium/rrd/router/sensor-temperature-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature-28.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature-28.rrd N:33]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.30]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":33}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30598']
SQL RUNTIME[0.00135803s]
RRD /opt/observium/rrd/router/alert-30598.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30598.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.31]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00044298s]
Checking (snmp) current Ten-GigabitEthernet1/0/26 Bias Current

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3604"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "current"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.17.28"
  [sensor_mib]                => string(25) "HH3C-TRANSCEIVER-INFO-MIB"
  [sensor_object]             => string(26) "hh3cTransceiverBiasCurrent"
  [sensor_index]              => string(2) "28"
  [sensor_type]               => string(52) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent"
  [sensor_descr]              => string(38) "Ten-GigabitEthernet1/0/26 Bias Current"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(7) "0.00001"
  [sensor_limit]              => string(8) "0.041595"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => string(4) "port"
  [measured_entity]           => string(4) "3987"
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(7) "0.02816"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(2816)
)
RRD /opt/observium/rrd/router/sensor-current-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent-28.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-current-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent-28.rrd N:0.02816]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.31]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00045013s]
Checking (snmp) voltage Ten-GigabitEthernet1/0/26 Voltage

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3605"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(7) "voltage"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.16.28"
  [sensor_mib]                => string(25) "HH3C-TRANSCEIVER-INFO-MIB"
  [sensor_object]             => string(22) "hh3cTransceiverVoltage"
  [sensor_index]              => string(2) "28"
  [sensor_type]               => string(48) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage"
  [sensor_descr]              => string(33) "Ten-GigabitEthernet1/0/26 Voltage"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(4) "0.01"
  [sensor_limit]              => string(6) "3.7835"
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => string(4) "port"
  [measured_entity]           => string(4) "3987"
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(7) "3.28000"
  [sensor_event]              => string(2) "ok"
  [sensor_status]             => string(0) ""
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1546926313"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(329)
)
RRD /opt/observium/rrd/router/sensor-voltage-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage-28.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-voltage-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage-28.rrd N:3.29]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.31]
RRD_STATUS[TRUE]


SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`]
SQL RUNTIME[0.00030804s]
Checking (snmp) dbm Ten-GigabitEthernet1/0/26 RX Power

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3607"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(3) "dbm"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.12.28"
  [sensor_mib]                => string(25) "HH3C-TRANSCEIVER-INFO-MIB"
  [sensor_object]             => string(25) "hh3cTransceiverCurRXPower"
  [sensor_index]              => string(2) "28"
  [sensor_type]               => string(51) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower"
  [sensor_descr]              => string(34) "Ten-GigabitEthernet1/0/26 RX Power"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(4) "0.01"
  [sensor_limit]              => null
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => string(4) "port"
  [measured_entity]           => string(4) "3987"
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "-1.92000"
  [sensor_event]              => string(5) "alert"
  [sensor_status]             => string(36) "Sensor critical thresholds exceeded."
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1553616013"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(-192)
)
RRD /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower-28.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower-28.rrd N:-1.92]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.31]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":-1.92},\"failed\":[{\"metric\":\"sensor_value\",\"condition\":\"greater\",\"value\":null},{\"metric\":\"sensor_value\",\"condition\":\"less\",\"value\":\"0\"}]}',`count` ='68',`alert_status` ='0',`last_message` ='Checks failed',`last_checked` ='1553635659',`last_failed` ='1553635659' WHERE `alert_table_id` = '30600']
SQL RUNTIME[0.00276589s]
RRD /opt/observium/rrd/router/alert-30600.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30600.rrd N:0:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.32]
RRD_STATUS[TRUE]

Checking (snmp) dbm Ten-GigabitEthernet1/0/26 TX Power

  /opt/observium/includes/polling/functions.inc.php:80
array(
  [sensor_id]                 => string(4) "3606"
  [sensor_deleted]            => string(1) "0"
  [sensor_class]              => string(3) "dbm"
  [device_id]                 => string(2) "39"
  [poller_type]               => string(4) "snmp"
  [sensor_oid]                => string(33) "1.3.6.1.4.1.25506.2.70.1.1.1.9.28"
  [sensor_mib]                => string(25) "HH3C-TRANSCEIVER-INFO-MIB"
  [sensor_object]             => string(25) "hh3cTransceiverCurTXPower"
  [sensor_index]              => string(2) "28"
  [sensor_type]               => string(51) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower"
  [sensor_descr]              => string(34) "Ten-GigabitEthernet1/0/26 TX Power"
  [sensor_unit]               => null
  [sensor_multiplier]         => string(4) "0.01"
  [sensor_limit]              => null
  [sensor_limit_warn]         => null
  [sensor_limit_low]          => string(1) "0"
  [sensor_limit_low_warn]     => null
  [sensor_custom_limit]       => string(1) "0"
  [entPhysicalIndex_measured] => null
  [measured_class]            => string(4) "port"
  [measured_entity]           => string(4) "3987"
  [entPhysicalIndex]          => null
  [entPhysicalClass]          => null
  [sensor_ignore]             => string(1) "0"
  [sensor_disable]            => string(1) "0"
  [sensor_value]              => string(8) "-1.80000"
  [sensor_event]              => string(5) "alert"
  [sensor_status]             => string(36) "Sensor critical thresholds exceeded."
  [sensor_polled]             => string(10) "1553635511"
  [sensor_last_change]        => string(10) "1553616013"
)
value taken from oid_cache


  /opt/observium/includes/polling/functions.inc.php:177
array(
  [sensor_value] => int(-179)
)
RRD /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower-28.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower-28.rrd N:-1.79]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.32]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":-1.79},\"failed\":[{\"metric\":\"sensor_value\",\"condition\":\"greater\",\"value\":null},{\"metric\":\"sensor_value\",\"condition\":\"less\",\"value\":\"0\"}]}',`count` ='68',`alert_status` ='0',`last_message` ='Checks failed',`last_checked` ='1553635659',`last_failed` ='1553635659' WHERE `alert_table_id` = '30599']
SQL RUNTIME[0.00150609s]
RRD /opt/observium/rrd/router/alert-30599.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-30599.rrd N:0:0]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.32]
RRD_STATUS[TRUE]

MultiUpdate sensors DB.

SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`)  VALUES ('3600','39','ok','','1546926313','1553635659'),('3601','39','ok','','1546926313','1553635659'),('3602','39','ok','','1546926313','1553635659'),('3603','33','ok','','1546926313','1553635659'),('3604','0.02816','ok','','1546926313','1553635659'),('3605','3.29','ok','','1546926313','1553635659'),('3607','-1.92','alert','Sensor critical thresholds exceeded.','1553616013','1553635659'),('3606','-1.79','alert','Sensor critical thresholds exceeded.','1553616013','1553635659') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)]
SQL RUNTIME[0.00109792s]
+----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+
| Descr                                  | Class       | Type                                                 | Origin | Value    | Event | Last Changed        |
+----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+
| Board                                  | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature         | snmp   | 39&deg;C | ok    | 2019-01-08 05:45:13 |
| SENSOR 1                               | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature         | snmp   | 39&deg;C | ok    | 2019-01-08 05:45:13 |
| SubCard0                               | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature         | snmp   | 39&deg;C | ok    | 2019-01-08 05:45:13 |
| Ten-GigabitEthernet1/0/26 Temperature  | temperature | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature | snmp   | 33&deg;C | ok    | 2019-01-08 05:45:13 |
| Ten-GigabitEthernet1/0/26 Bias Current | current     | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent | snmp   | 0.02816A | ok    | 2019-01-08 05:45:13 |
| Ten-GigabitEthernet1/0/26 Voltage      | voltage     | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage     | snmp   | 3.29V    | ok    | 2019-01-08 05:45:13 |
| Ten-GigabitEthernet1/0/26 RX Power     | dbm         | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower  | snmp   | -1.92dBm | alert | 2019-03-26 16:00:13 |
| Ten-GigabitEthernet1/0/26 TX Power     | dbm         | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower  | snmp   | -1.79dBm | alert | 2019-03-26 16:00:13 |
+----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+

 o Module time          0.0895s

#####  router [39] completed poller modules at 2019-03-26 22:27:39  #####

 o Graphs [checked]     availability, ping, ping_snmp, uptime, temperature, current, voltage, dbm
 o Poller time          0.3403 seconds
Updating router -

 > $update_array /opt/observium/includes/polling/functions.inc.php:867
array(
  [uptime]                => int(154343772)
  [last_polled]           => array(
                               [0] => string(5) "NOW()"
                             )
  [last_polled_timetaken] => double(0.3403)
)


SQL[UPDATE `devices` set `uptime` ='154343772',`last_polled` =NOW(),`last_polled_timetaken` ='0.3403' WHERE `device_id` = '39']
SQL RUNTIME[0.00227714s]
 o Updated Data         uptime, last_polled, last_polled_timetaken

SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_status_type\":\"ok\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '3638']
SQL RUNTIME[0.00114202s]
RRD /opt/observium/rrd/router/alert-3638.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-3638.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.34]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_rebooted\":0}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '21258']
SQL RUNTIME[0.00189590s]
RRD /opt/observium/rrd/router/alert-21258.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-21258.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.34]
RRD_STATUS[TRUE]


SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_ping\":\"12.6\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '27418']
SQL RUNTIME[0.00053310s]
RRD /opt/observium/rrd/router/alert-27418.rrd already exists - no need to create.

RRD CMD[update /opt/observium/rrd/router/alert-27418.rrd N:1:1]
RRD RUNTIME[0.0011s]
RRD STDOUT[OK u:0.00 s:0.00 r:0.34]
RRD_STATUS[TRUE]



SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '27088' AND `process_name` = 'poller.php' AND `device_id` = '39']
SQL RUNTIME[0.00112104s]
./poller.php: router - 1 devices polled in 0.433 secs
#####  Completed polling run at 2019-03-26 22:27:40  #####

NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output.
 o Devices Polled       1
 o Poller Time          0.433 secs
 o Memory usage         4MB (peak: 4MB)
 o MySQL Usage          Insert[1/0.008s] Update[14/0.028s] Delete[1/0.001s] Cell[4/0.001s] Row[13/0.006s] Rows[17/0.011s] Col[2/0.001s]
                        (0.057s13.128%)
 o RRDTool Usage        update[21/0.023s] (0.023s 5.289%)
 o SNMP Usage           snmpget[10/0.225s] errors[/0s] (0.225s 51.878%)