CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.0065s] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9785 Node Kind: directory Schedule: normal Last Changed Author: mike Last Changed Rev: 9785 Last Changed Date: 2019-03-25 23:09:57 +0100 (Mon, 25 Mar 2019) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00030708s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00013709s] SQL[SET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00010204s] DB mode(s) disabled: STRICT_TRANS_TABLES, ONLY_FULL_GROUP_BY SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00013709s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00020981s] CMD[/bin/hostname -f] CMD EXITCODE[0] CMD RUNTIME[0.001s] STDOUT[ sat-nms01 ] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 19.3.9785 http://www.observium.org SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00020719s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00013089s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00014806s] There is a newer revision of Observium available! CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0007s] CMD EXITDELAY[10ms] STDOUT[ +01:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00026202s] Version 19.3.9786 (26th March 2019) is 1 revisions ahead. CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.0067s] STDOUT[ Linux|4.4.0-142-generic|amd64|Ubuntu|16.04|vmware| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0014s] STDOUT[ Python 2.7.12 ] SQL[SELECT version();] SQL RUNTIME[0.00011086s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0013s] STDOUT[ NET-SNMP version: 5.7.3 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0053s] STDOUT[ RRDtool 1.5.5 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0011s] STDOUT[ /usr/bin/fping: Version 3.13 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0324s] STDOUT[ Apache/2.4.18 ] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00024891s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00163388s] ##### Software versions ##### o OS Linux 4.4.0-142-generic [amd64] (Ubuntu 16.04) o Apache 2.4.18 o PHP 7.0.33-0ubuntu0.16.04.2 (OPcache: ENABLED) o Python 2.7.12 o MySQL 5.7.25-0ubuntu0.16.04.2 (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.3 o RRDtool 1.5.5 o Fping 3.13 (IPv4 and IPv6) ##### Memory Limit ##### o PHP Unlimited ##### MySQL mode ##### o MySQL NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Tuesday, 26-Mar-19 22:27:39 CET o PHP +01:00 o MySQL +01:00 SQL[SELECT * FROM `alerts_maint` WHERE `maint_start` < '1553635659' AND `maint_end` > '1553635659'] SQL RUNTIME[0.00043392s] ##### Starting polling run at 2019-03-26 22:27:39 ##### SQL[SELECT `device_id` FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'router' AND `poller_id` = '0' ORDER BY `device_id` ASC] SQL RUNTIME[0.00051308s] SQL[SELECT * FROM `devices` WHERE `device_id` = '39'] SQL RUNTIME[0.00043607s] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39'] SQL RUNTIME[0.00045514s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'poller.php' AND `device_id` = '39'] SQL RUNTIME[0.00029111s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('27088','poller.php','5746','0','php ./poller.php -d -m sensors -h router','1553635659','39')] SQL RUNTIME[0.00814009s] SQL[SELECT * FROM `alert_tests` WHERE 1] SQL RUNTIME[0.00038910s] Cached 15 alert rules. SQL[SELECT * FROM `alert_table` WHERE `device_id` = '39'] SQL RUNTIME[0.00119400s] ##### router [39] ##### o OS hh3c o Last poll duration 7.52 seconds o Last Polled 2019-03-26 22:25:19 o SNMP Version v2c CMD[/usr/bin/fping -t 500 -c 1 -q 10.254.196.15 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0137s] STDOUT[ 10.254.196.15 : xmt/rcv/%loss = 1/1/0%, min/avg/max = 12.6/12.6/12.6 ] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0227s] STDOUT[ sysObjectID.0 = enterprises.25506.11.1.20 sysUpTime.0 = 295:1:53:10.25 ] SNMP STATUS[TRUE] o Device status Device is reachable by PING (12.6ms) and SNMP (22.67ms) RRD /opt/observium/rrd/router/status.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/status.rrd N:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.05] RRD_STATUS[TRUE] RRD /opt/observium/rrd/router/ping.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/ping.rrd N:12.6] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.05] RRD_STATUS[TRUE] RRD /opt/observium/rrd/router/ping_snmp.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/ping_snmp.rrd N:22.67] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.05] RRD_STATUS[TRUE] SQL[SELECT * FROM `device_graphs` WHERE `device_id` = '39'] SQL RUNTIME[0.00041199s] o Modules Enabled system, os, sensors including: includes/polling/system.inc.php ##### Module Start: system ##### SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00018787s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '39' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00014591s] SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.00012207s] o SNMPv2-MIB CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysUpTime.0 sysLocation.0 sysContact.0 sysName.0] CMD EXITCODE[0] CMD RUNTIME[0.0197s] STDOUT[ sysUpTime.0 = 295:1:53:10.28 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysDescr.0] CMD EXITCODE[0] CMD RUNTIME[0.0189s] STDOUT[ HP Comware Platform Software, Software Version 5.20.105, Release 1808P21 HP A5800-24G-SFP Switch with 1 Interface Slot Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P. ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUvn -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' sysObjectID.0] CMD EXITCODE[0] CMD RUNTIME[0.023s] STDOUT[ .1.3.6.1.4.1.25506.11.1.20 ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' snmpEngineID.0] CMD EXITCODE[0] CMD RUNTIME[0.0219s] STDOUT[ "80 00 00 0B 03 CC 3E 5F A1 F7 AB " ] SNMP STATUS[TRUE] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m HOST-RESOURCES-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' hrSystemUptime.0] CMD EXITCODE[0] CMD RUNTIME[0.0203s] STDOUT[ No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HOST-RESOURCES-MIB' AND `oid` = 'hrSystemUptime.0';] SQL RUNTIME[0.00060797s] SQL[UPDATE `snmp_errors` set `error_count` ='94065',`updated` ='1553635659' WHERE `error_id` = '337'] SQL RUNTIME[0.00196290s] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m SNMP-FRAMEWORK-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' snmpEngineTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0186s] STDOUT[ 154343772 ] SNMP STATUS[TRUE] Using SNMP Agent snmpEngineTime (154343772 sec. => 4 years, 326 days, 9h 16m 12s) RRD /opt/observium/rrd/router/uptime.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/uptime.rrd N:154343772] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.19] RRD_STATUS[TRUE] o Uptime 4 years, 326 days, 9h 16m 12s o Last reboot 2014-05-05 12:09:09 /opt/observium/includes/polling/system.inc.php:286 array( [use] => string(14) "snmpEngineTime" [sysUpTime] => int(25494790) [hrSystemUptime] => bool(false) [snmpEngineTime] => int(154343772) [uptime] => int(154343772) [formatted] => string(29) "4 years, 326 days, 9h 16m 12s" [message] => string(31) "Using SNMP Agent snmpEngineTime" [previous] => string(9) "154343624" [diff] => int(-148) [last_rebooted] => string(10) "1399291749" [rebooted] => int(0) ) CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUsn -m UCD-SNMP-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' .1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3] CMD EXITCODE[0] CMD RUNTIME[0.0193s] STDOUT[ .1.3.6.1.4.1.2021.10.1.5.1 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.2 = No Such Object available on this agent at this OID .1.3.6.1.4.1.2021.10.1.5.3 = No Such Object available on this agent at this OID ] SNMP ERROR[#1000 - Failed response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1000' AND `snmp_cmd` = 'snmpget' AND `mib` = 'UCD-SNMP-MIB' AND `oid` = '.1.3.6.1.4.1.2021.10.1.5.1 .1.3.6.1.4.1.2021.10.1.5.2 .1.3.6.1.4.1.2021.10.1.5.3';] SQL RUNTIME[0.00037122s] SQL[UPDATE `snmp_errors` set `error_count` ='88128',`updated` ='1553635659' WHERE `error_id` = '2952'] SQL RUNTIME[0.00501990s] SNMP STATUS[FALSE] o sysObjectID .1.3.6.1.4.1.25506.11.1.20 o snmpEngineID 8000000B03CC3E5FA1F7AB o sysDescr HP Comware Platform Software, Software Version 5.20.105, Release 1808P21 HP A5800-24G-SFP Switch with 1 Interface Slot Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P. o sysName router o Location Address SQL[SELECT * FROM `devices_locations` WHERE `device_id` = '39'] SQL RUNTIME[0.00034809s] o Module time 0.1642s including: includes/polling/os.inc.php ##### Module Start: os ##### SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '39' AND `entPhysicalContainedIn` = '0' AND `deleted` IS NULL] SQL RUNTIME[0.00046515s] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUv -m HH3C-ENTITY-EXT-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/hh3c 'udp':'router':'161' hh3cEntityExtManuSerialNum.1] CMD EXITCODE[0] CMD RUNTIME[0.0222s] STDOUT[ ] SNMP STATUS[FALSE] SNMP ERROR[#1 - Empty response] SQL[SELECT * FROM `snmp_errors` WHERE `device_id` = '39' AND `error_code` = '1' AND `snmp_cmd` = 'snmpget' AND `mib` = 'HH3C-ENTITY-EXT-MIB' AND `oid` = 'hh3cEntityExtManuSerialNum.1';] SQL RUNTIME[0.00028014s] SQL[UPDATE `snmp_errors` set `error_count` ='94065',`updated` ='1553635659' WHERE `error_id` = '338'] SQL RUNTIME[0.00138402s] o OS Poller OS o Vendor HPE o Hardware HP A5800-24G-SFP Switch with 1 Interface Slot o Version 5.20.105 1808P21 o Features o Serial o Asset o Module time 0.0288s including: includes/polling/sensors.inc.php ##### Module Start: sensors ##### SQL[SELECT DISTINCT `sensor_class` FROM `sensors` WHERE `device_id` = '39' AND `sensor_deleted` = '0' AND `sensor_class` IN ('temperature','humidity','fanspeed','dewpoint','airflow','voltage','current','charge','power','energy','apower','rpower','crestfactor','powerfactor','impedance','resistance','frequency','dbm','snr','dust','sound','capacity','load','runtime','volume','waterflow','pressure','velocity','illuminance','wavelength','counter')] SQL RUNTIME[0.00065708s] SQL[SELECT * FROM `entity_attribs` WHERE `device_id` = '39' AND `entity_type` IN ('sensor')] SQL RUNTIME[0.00020313s] SQL[SELECT `sensor_oid` FROM `sensors` WHERE `device_id` = '39' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00023293s] CMD[/usr/bin/snmpget -t '15' -r '3' -v2c -c *** -Pu -OQUsn -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'router':'161' .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262 1.3.6.1.4.1.25506.2.70.1.1.1.9.28 1.3.6.1.4.1.25506.2.70.1.1.1.12.28 1.3.6.1.4.1.25506.2.70.1.1.1.15.28 1.3.6.1.4.1.25506.2.70.1.1.1.16.28 1.3.6.1.4.1.25506.2.70.1.1.1.17.28] CMD EXITCODE[0] CMD RUNTIME[0.0379s] STDOUT[ .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112 = 39 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118 = 39 .1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262 = 39 .1.3.6.1.4.1.25506.2.70.1.1.1.9.28 = -179 .1.3.6.1.4.1.25506.2.70.1.1.1.12.28 = -192 .1.3.6.1.4.1.25506.2.70.1.1.1.15.28 = 33 .1.3.6.1.4.1.25506.2.70.1.1.1.16.28 = 329 .1.3.6.1.4.1.25506.2.70.1.1.1.17.28 = 2816 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00042415s] Checking (snmp) temperature Board /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3600" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.112" [sensor_mib] => string(19) "HH3C-ENTITY-EXT-MIB" [sensor_object] => string(24) "hh3cEntityExtTemperature" [sensor_index] => string(3) "112" [sensor_type] => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature" [sensor_descr] => string(5) "Board" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(4) "62.4" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "39.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(39) ) RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-112.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-112.rrd N:39] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.29] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30595'] SQL RUNTIME[0.00151205s] RRD /opt/observium/rrd/router/alert-30595.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30595.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.29] RRD_STATUS[TRUE] Checking (snmp) temperature SENSOR 1 /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3601" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.118" [sensor_mib] => string(19) "HH3C-ENTITY-EXT-MIB" [sensor_object] => string(24) "hh3cEntityExtTemperature" [sensor_index] => string(3) "118" [sensor_type] => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature" [sensor_descr] => string(8) "SENSOR 1" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(2) "75" [sensor_limit_warn] => string(2) "65" [sensor_limit_low] => string(1) "5" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "39.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(39) ) RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-118.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-118.rrd N:39] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.29] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30596'] SQL RUNTIME[0.00129604s] RRD /opt/observium/rrd/router/alert-30596.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30596.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.29] RRD_STATUS[TRUE] Checking (snmp) temperature SubCard0 /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3602" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(37) ".1.3.6.1.4.1.25506.2.6.1.1.1.1.12.262" [sensor_mib] => string(19) "HH3C-ENTITY-EXT-MIB" [sensor_object] => string(24) "hh3cEntityExtTemperature" [sensor_index] => string(3) "262" [sensor_type] => string(44) "HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature" [sensor_descr] => string(8) "SubCard0" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(4) "62.4" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => null [measured_entity] => null [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "39.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(39) ) RRD /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-262.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature-262.rrd N:39] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.30] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":39}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30597'] SQL RUNTIME[0.00270796s] RRD /opt/observium/rrd/router/alert-30597.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30597.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.30] RRD_STATUS[TRUE] Checking (snmp) temperature Ten-GigabitEthernet1/0/26 Temperature /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3603" [sensor_deleted] => string(1) "0" [sensor_class] => string(11) "temperature" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.15.28" [sensor_mib] => string(25) "HH3C-TRANSCEIVER-INFO-MIB" [sensor_object] => string(26) "hh3cTransceiverTemperature" [sensor_index] => string(2) "28" [sensor_type] => string(52) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature" [sensor_descr] => string(37) "Ten-GigabitEthernet1/0/26 Temperature" [sensor_unit] => null [sensor_multiplier] => string(1) "1" [sensor_limit] => string(4) "51.2" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => string(4) "port" [measured_entity] => string(4) "3987" [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "33.00000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(33) ) RRD /opt/observium/rrd/router/sensor-temperature-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature-28.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-temperature-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature-28.rrd N:33] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.30] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":33}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635659',`last_ok` ='1553635659' WHERE `alert_table_id` = '30598'] SQL RUNTIME[0.00135803s] RRD /opt/observium/rrd/router/alert-30598.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30598.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.31] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00044298s] Checking (snmp) current Ten-GigabitEthernet1/0/26 Bias Current /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3604" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "current" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.17.28" [sensor_mib] => string(25) "HH3C-TRANSCEIVER-INFO-MIB" [sensor_object] => string(26) "hh3cTransceiverBiasCurrent" [sensor_index] => string(2) "28" [sensor_type] => string(52) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent" [sensor_descr] => string(38) "Ten-GigabitEthernet1/0/26 Bias Current" [sensor_unit] => null [sensor_multiplier] => string(7) "0.00001" [sensor_limit] => string(8) "0.041595" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => string(4) "port" [measured_entity] => string(4) "3987" [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "0.02816" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(2816) ) RRD /opt/observium/rrd/router/sensor-current-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent-28.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-current-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent-28.rrd N:0.02816] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.31] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00045013s] Checking (snmp) voltage Ten-GigabitEthernet1/0/26 Voltage /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3605" [sensor_deleted] => string(1) "0" [sensor_class] => string(7) "voltage" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.16.28" [sensor_mib] => string(25) "HH3C-TRANSCEIVER-INFO-MIB" [sensor_object] => string(22) "hh3cTransceiverVoltage" [sensor_index] => string(2) "28" [sensor_type] => string(48) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage" [sensor_descr] => string(33) "Ten-GigabitEthernet1/0/26 Voltage" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => string(6) "3.7835" [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => string(4) "port" [measured_entity] => string(4) "3987" [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(7) "3.28000" [sensor_event] => string(2) "ok" [sensor_status] => string(0) "" [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1546926313" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(329) ) RRD /opt/observium/rrd/router/sensor-voltage-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage-28.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-voltage-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage-28.rrd N:3.29] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.31] RRD_STATUS[TRUE] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'dbm' AND `device_id` = '39' AND `sensor_deleted` = '0' ORDER BY `sensor_oid`] SQL RUNTIME[0.00030804s] Checking (snmp) dbm Ten-GigabitEthernet1/0/26 RX Power /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3607" [sensor_deleted] => string(1) "0" [sensor_class] => string(3) "dbm" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(34) "1.3.6.1.4.1.25506.2.70.1.1.1.12.28" [sensor_mib] => string(25) "HH3C-TRANSCEIVER-INFO-MIB" [sensor_object] => string(25) "hh3cTransceiverCurRXPower" [sensor_index] => string(2) "28" [sensor_type] => string(51) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower" [sensor_descr] => string(34) "Ten-GigabitEthernet1/0/26 RX Power" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => string(4) "port" [measured_entity] => string(4) "3987" [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "-1.92000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1553616013" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(-192) ) RRD /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower-28.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower-28.rrd N:-1.92] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.31] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":-1.92},\"failed\":[{\"metric\":\"sensor_value\",\"condition\":\"greater\",\"value\":null},{\"metric\":\"sensor_value\",\"condition\":\"less\",\"value\":\"0\"}]}',`count` ='68',`alert_status` ='0',`last_message` ='Checks failed',`last_checked` ='1553635659',`last_failed` ='1553635659' WHERE `alert_table_id` = '30600'] SQL RUNTIME[0.00276589s] RRD /opt/observium/rrd/router/alert-30600.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30600.rrd N:0:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.32] RRD_STATUS[TRUE] Checking (snmp) dbm Ten-GigabitEthernet1/0/26 TX Power /opt/observium/includes/polling/functions.inc.php:80 array( [sensor_id] => string(4) "3606" [sensor_deleted] => string(1) "0" [sensor_class] => string(3) "dbm" [device_id] => string(2) "39" [poller_type] => string(4) "snmp" [sensor_oid] => string(33) "1.3.6.1.4.1.25506.2.70.1.1.1.9.28" [sensor_mib] => string(25) "HH3C-TRANSCEIVER-INFO-MIB" [sensor_object] => string(25) "hh3cTransceiverCurTXPower" [sensor_index] => string(2) "28" [sensor_type] => string(51) "HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower" [sensor_descr] => string(34) "Ten-GigabitEthernet1/0/26 TX Power" [sensor_unit] => null [sensor_multiplier] => string(4) "0.01" [sensor_limit] => null [sensor_limit_warn] => null [sensor_limit_low] => string(1) "0" [sensor_limit_low_warn] => null [sensor_custom_limit] => string(1) "0" [entPhysicalIndex_measured] => null [measured_class] => string(4) "port" [measured_entity] => string(4) "3987" [entPhysicalIndex] => null [entPhysicalClass] => null [sensor_ignore] => string(1) "0" [sensor_disable] => string(1) "0" [sensor_value] => string(8) "-1.80000" [sensor_event] => string(5) "alert" [sensor_status] => string(36) "Sensor critical thresholds exceeded." [sensor_polled] => string(10) "1553635511" [sensor_last_change] => string(10) "1553616013" ) value taken from oid_cache /opt/observium/includes/polling/functions.inc.php:177 array( [sensor_value] => int(-179) ) RRD /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower-28.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/sensor-dbm-HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower-28.rrd N:-1.79] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.32] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"sensor_value\":-1.79},\"failed\":[{\"metric\":\"sensor_value\",\"condition\":\"greater\",\"value\":null},{\"metric\":\"sensor_value\",\"condition\":\"less\",\"value\":\"0\"}]}',`count` ='68',`alert_status` ='0',`last_message` ='Checks failed',`last_checked` ='1553635659',`last_failed` ='1553635659' WHERE `alert_table_id` = '30599'] SQL RUNTIME[0.00150609s] RRD /opt/observium/rrd/router/alert-30599.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-30599.rrd N:0:0] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.32] RRD_STATUS[TRUE] MultiUpdate sensors DB. SQL[INSERT INTO `sensors` (`sensor_id`,`sensor_value`,`sensor_event`,`sensor_status`,`sensor_last_change`,`sensor_polled`) VALUES ('3600','39','ok','','1546926313','1553635659'),('3601','39','ok','','1546926313','1553635659'),('3602','39','ok','','1546926313','1553635659'),('3603','33','ok','','1546926313','1553635659'),('3604','0.02816','ok','','1546926313','1553635659'),('3605','3.29','ok','','1546926313','1553635659'),('3607','-1.92','alert','Sensor critical thresholds exceeded.','1553616013','1553635659'),('3606','-1.79','alert','Sensor critical thresholds exceeded.','1553616013','1553635659') ON DUPLICATE KEY UPDATE `sensor_id`=VALUES(`sensor_id`),`sensor_value`=VALUES(`sensor_value`),`sensor_event`=VALUES(`sensor_event`),`sensor_status`=VALUES(`sensor_status`),`sensor_last_change`=VALUES(`sensor_last_change`),`sensor_polled`=VALUES(`sensor_polled`)] SQL RUNTIME[0.00109792s] +----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+ | Descr | Class | Type | Origin | Value | Event | Last Changed | +----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+ | Board | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature | snmp | 39°C | ok | 2019-01-08 05:45:13 | | SENSOR 1 | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature | snmp | 39°C | ok | 2019-01-08 05:45:13 | | SubCard0 | temperature | HH3C-ENTITY-EXT-MIB-hh3cEntityExtTemperature | snmp | 39°C | ok | 2019-01-08 05:45:13 | | Ten-GigabitEthernet1/0/26 Temperature | temperature | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverTemperature | snmp | 33°C | ok | 2019-01-08 05:45:13 | | Ten-GigabitEthernet1/0/26 Bias Current | current | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverBiasCurrent | snmp | 0.02816A | ok | 2019-01-08 05:45:13 | | Ten-GigabitEthernet1/0/26 Voltage | voltage | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverVoltage | snmp | 3.29V | ok | 2019-01-08 05:45:13 | | Ten-GigabitEthernet1/0/26 RX Power | dbm | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurRXPower | snmp | -1.92dBm | alert | 2019-03-26 16:00:13 | | Ten-GigabitEthernet1/0/26 TX Power | dbm | HH3C-TRANSCEIVER-INFO-MIB-hh3cTransceiverCurTXPower | snmp | -1.79dBm | alert | 2019-03-26 16:00:13 | +----------------------------------------+-------------+------------------------------------------------------+--------+----------+-------+---------------------+ o Module time 0.0895s ##### router [39] completed poller modules at 2019-03-26 22:27:39 ##### o Graphs [checked] availability, ping, ping_snmp, uptime, temperature, current, voltage, dbm o Poller time 0.3403 seconds Updating router - > $update_array /opt/observium/includes/polling/functions.inc.php:867 array( [uptime] => int(154343772) [last_polled] => array( [0] => string(5) "NOW()" ) [last_polled_timetaken] => double(0.3403) ) SQL[UPDATE `devices` set `uptime` ='154343772',`last_polled` =NOW(),`last_polled_timetaken` ='0.3403' WHERE `device_id` = '39'] SQL RUNTIME[0.00227714s] o Updated Data uptime, last_polled, last_polled_timetaken SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_status_type\":\"ok\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '3638'] SQL RUNTIME[0.00114202s] RRD /opt/observium/rrd/router/alert-3638.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-3638.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.34] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_rebooted\":0}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '21258'] SQL RUNTIME[0.00189590s] RRD /opt/observium/rrd/router/alert-21258.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-21258.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.34] RRD_STATUS[TRUE] SQL[UPDATE `alert_table` set `state` ='{\"metrics\":{\"device_ping\":\"12.6\"}}',`count` ='0',`alert_status` ='1',`last_message` ='Checks OK',`last_checked` ='1553635660',`last_ok` ='1553635660' WHERE `alert_table_id` = '27418'] SQL RUNTIME[0.00053310s] RRD /opt/observium/rrd/router/alert-27418.rrd already exists - no need to create. RRD CMD[update /opt/observium/rrd/router/alert-27418.rrd N:1:1] RRD RUNTIME[0.0011s] RRD STDOUT[OK u:0.00 s:0.00 r:0.34] RRD_STATUS[TRUE] SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '27088' AND `process_name` = 'poller.php' AND `device_id` = '39'] SQL RUNTIME[0.00112104s] ./poller.php: router - 1 devices polled in 0.433 secs ##### Completed polling run at 2019-03-26 22:27:40 ##### NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Polled 1 o Poller Time 0.433 secs o Memory usage 4MB (peak: 4MB) o MySQL Usage Insert[1/0.008s] Update[14/0.028s] Delete[1/0.001s] Cell[4/0.001s] Row[13/0.006s] Rows[17/0.011s] Col[2/0.001s] (0.057s13.128%) o RRDTool Usage update[21/0.023s] (0.023s 5.289%) o SNMP Usage snmpget[10/0.225s] errors[/0s] (0.225s 51.878%)