DEBUG! CMD[/usr/bin/svn info /opt/observium] CMD EXITCODE[0] CMD RUNTIME[0.022s] CMD EXITDELAY[10ms] STDOUT[ Path: . Working Copy Root Path: /opt/observium URL: http://svn.observium.org/svn/observium/trunk Relative URL: ^/observium/trunk Repository Root: http://svn.observium.org/svn Repository UUID: 61d68cd4-352d-0410-923a-c4978735b2b8 Revision: 9501 Node Kind: directory Schedule: normal Last Changed Author: adama Last Changed Rev: 9501 Last Changed Date: 2018-10-24 04:49:58 +0100 (Wed, 24 Oct 2018) ] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'dbSchema';] SQL RUNTIME[0.00057006s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00029302s] SQL[SET SESSION `sql_mode` = 'NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION'] SQL RUNTIME[0.00019503s] DB mode(s) disabled: STRICT_TRANS_TABLES SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'current_rev';] SQL RUNTIME[0.00046396s] SQL[SELECT * FROM `config`] SQL RUNTIME[0.00068188s] ___ _ _ / _ \ | |__ ___ ___ _ __ __ __(_) _ _ _ __ ___ | | | || '_ \ / __| / _ \| '__|\ \ / /| || | | || '_ ` _ \ | |_| || |_) |\__ \| __/| | \ V / | || |_| || | | | | | \___/ |_.__/ |___/ \___||_| \_/ |_| \__,_||_| |_| |_| Observium Professional 18.10.9501 http://www.observium.org CMD[/opt/observium/scripts/distro] CMD EXITCODE[0] CMD RUNTIME[0.0414s] STDOUT[ Linux|4.4.0-139-generic|amd64|Ubuntu|16.04|| ] CMD[/usr/bin/env python --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0061s] STDOUT[ Python 2.7.12 ] SQL[SELECT version();] SQL RUNTIME[0.00045085s] CMD[/usr/bin/snmpget --version 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0051s] STDOUT[ NET-SNMP version: 5.7.3 ] CMD[/usr/bin/rrdtool --version | head -n1] CMD EXITCODE[0] CMD RUNTIME[0.0252s] STDOUT[ RRDtool 1.5.5 Copyright by Tobias Oetiker ] CMD[/usr/bin/fping -v 2>&1] CMD EXITCODE[0] CMD RUNTIME[0.0041s] STDOUT[ /usr/bin/fping: Version 3.13 /usr/bin/fping: comments to david@schweikert.ch ] CMD[/usr/sbin/apache2 -v | awk '/Server version:/ {print $3}'] CMD EXITCODE[0] CMD RUNTIME[0.0899s] STDOUT[ Apache/2.4.18 ] CMD[date "+%:z"] CMD EXITCODE[0] CMD RUNTIME[0.0019s] CMD EXITDELAY[10ms] STDOUT[ +00:00 ] SQL[SELECT TIMEDIFF(NOW(), UTC_TIMESTAMP);] SQL RUNTIME[0.00041795s] SQL[SELECT @@SESSION.sql_mode;] SQL RUNTIME[0.00036192s] SQL[SHOW VARIABLES LIKE 'character_set_connection'] SQL RUNTIME[0.00612712s] ##### Software versions ##### o OS Linux 4.4.0-139-generic [amd64] (Ubuntu 16.04) o Apache 2.4.18 o PHP 7.0.33-1+ubuntu16.04.1+deb.sury.org+1 (OPcache: ENABLED) o Python 2.7.12 o MySQL 5.7.24-0ubuntu0.16.04.1 (extension: mysqli 5.0.12-dev) o SNMP NET-SNMP 5.7.3 o RRDtool 1.5.5 o Fping 3.13 (IPv4 and IPv6) ##### Memory Limit ##### o PHP Unlimited ##### MySQL mode ##### o MySQL NO_ZERO_IN_DATE,NO_ZERO_DATE,ERROR_FOR_DIVISION_BY_ZERO,NO_AUTO_CREATE_USER,NO_ENGINE_SUBSTITUTION ##### Charset info ##### o PHP UTF-8 o MySQL utf8 ##### Timezones info ##### o Date Monday, 14-Jan-19 13:05:30 CET o PHP +01:00 o MySQL +01:00 SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'last_versioncheck';] SQL RUNTIME[0.00064588s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev';] SQL RUNTIME[0.00064111s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_ver';] SQL RUNTIME[0.00060511s] SQL[SELECT `attrib_value` FROM `observium_attribs` WHERE `attrib_type` = 'latest_rev_date';] SQL RUNTIME[0.00061607s] There is a newer revision of Observium available! Version 19.1.9669 (14th January 2019) is 168 revisions ahead. ##### Starting discovery run at 2019-01-14 13:05:30 ##### SQL[SELECT * FROM `devices` WHERE `disabled` = 0 AND `hostname` LIKE 'my-f5.test.com' AND `status` = '1' ORDER BY `last_discovered_timetaken` ASC] SQL RUNTIME[0.00166583s] CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUs -m SNMPv2-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'my-f5.test.com':'161' sysObjectID.0 sysUpTime.0] CMD EXITCODE[0] CMD RUNTIME[0.0895s] STDOUT[ sysObjectID.0 = enterprises.3375.2.1.3.4.20 sysUpTime.0 = 310:0:49:20.63 ] SNMP STATUS[TRUE] SQL[SELECT * FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '4'] SQL RUNTIME[0.00107384s] SQL[SELECT * FROM `observium_processes` WHERE `process_name` = 'discovery.php' AND `device_id` = '4'] SQL RUNTIME[0.00075102s] SQL[INSERT INTO `observium_processes` (`process_pid`,`process_name`,`process_ppid`,`process_uid`,`process_command`,`process_start`,`device_id`) VALUES ('16035','discovery.php','16034','0','php ./discovery.php -h my-f5.test.com -m sensors -d','1547467530','4')] SQL RUNTIME[0.05509090s] ##### my-f5.test.com [4] ##### o OS Type f5 o SNMP Version v2c o Last discovery 2019-01-14 13:05:19 o Last duration 3.14 seconds ##### Module Start: sensors ##### SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'device' AND `entity_id` = '4' AND `attrib_type` = 'sysORID'] SQL RUNTIME[0.00080204s] SQL[SELECT * FROM `observium_attribs`] SQL RUNTIME[0.00088787s] o ENTITY-SENSOR-MIB CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -OQUs -m ENTITY-MIB:ENTITY-SENSOR-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp 'udp':'my-f5.test.com':'161' entPhySensorValue] CMD EXITCODE[0] CMD RUNTIME[0.1595s] STDOUT[ entPhySensorValue = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o F5-BIGIP-APM-MIB CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -OQUs -m F5-BIGIP-APM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' apmPmStatConfigSyncState] CMD EXITCODE[0] CMD RUNTIME[0.2853s] STDOUT[ apmPmStatConfigSyncState = No Such Instance currently exists at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] o F5-BIGIP-SYSTEM-MIB sysChassisFanTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -Ih -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysChassisFanTable] CMD EXITCODE[0] CMD RUNTIME[0.2695s] STDOUT[ sysChassisFanIndex.1 = 1 sysChassisFanIndex.2 = 2 sysChassisFanIndex.3 = 3 sysChassisFanStatus.1 = good sysChassisFanStatus.2 = good sysChassisFanStatus.3 = good sysChassisFanSpeed.1 = 11250 sysChassisFanSpeed.2 = 12053 sysChassisFanSpeed.3 = 11637 ] SNMP STATUS[TRUE] Store in cache Table OID: F5-BIGIP-SYSTEM-MIB::sysChassisFanTable Discover sensor: fanspeed, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.3.1, 1, F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed, Chassis Fan 1, SCALE: 1, LIMITS: (, , , ), CURRENT: 11250, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '1'] SQL RUNTIME[0.00105405s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '1'] SQL RUNTIME[0.00121593s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '4' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00075984s] .Discover sensor: fanspeed, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.3.2, 2, F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed, Chassis Fan 2, SCALE: 1, LIMITS: (, , , ), CURRENT: 12053, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '2'] SQL RUNTIME[0.00101209s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '2'] SQL RUNTIME[0.00125003s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '5' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00089097s] .Discover sensor: fanspeed, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.3.3, 3, F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed, Chassis Fan 3, SCALE: 1, LIMITS: (, , , ), CURRENT: 11637, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '3'] SQL RUNTIME[0.00106788s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisFanSpeed' AND `sensor_index` = '3'] SQL RUNTIME[0.00118279s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '6' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00079393s] .] sysChassisTempTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -Ih -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysChassisTempTable] CMD EXITCODE[0] CMD RUNTIME[0.2605s] STDOUT[ sysChassisTempIndex.1 = 1 sysChassisTempTemperature.1 = 28 ] SNMP STATUS[TRUE] Discover sensor: temperature, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.3.2.1.2.1, 1, F5-BIGIP-SYSTEM-MIB-sysChassisTempTemperature, Chassis Temperature, SCALE: 1, LIMITS: (, , , ), CURRENT: 28, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisTempTemperature' AND `sensor_index` = '1'] SQL RUNTIME[0.00103402s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysChassisTempTemperature' AND `sensor_index` = '1'] SQL RUNTIME[0.00113106s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '7' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00075698s] .] sysCpuSensorTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -Ih -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysCpuSensorTable] CMD EXITCODE[0] CMD RUNTIME[0.2604s] STDOUT[ sysCpuSensorIndex.0.1 = 1 sysCpuSensorTemperature.0.1 = 39 sysCpuSensorFanSpeed.0.1 = 12053 sysCpuSensorName.0.1 = "cpu1" sysCpuSensorSlot.0.1 = 0 ] SNMP STATUS[TRUE] Store in cache Table OID: F5-BIGIP-SYSTEM-MIB::sysCpuSensorTable Discover sensor: fanspeed, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.6.2.1.3.0.1, 0.1, F5-BIGIP-SYSTEM-MIB-sysCpuSensorFanSpeed, Slot 0 CPU 1, SCALE: 1, LIMITS: (, , , ), CURRENT: 12053, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysCpuSensorFanSpeed' AND `sensor_index` = '0.1'] SQL RUNTIME[0.00098681s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysCpuSensorFanSpeed' AND `sensor_index` = '0.1'] SQL RUNTIME[0.00114417s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '8' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00082517s] .Get cached Table OID: F5-BIGIP-SYSTEM-MIB::sysCpuSensorTable Discover sensor: temperature, my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.6.2.1.2.0.1, 0.1, F5-BIGIP-SYSTEM-MIB-sysCpuSensorTemperature, Slot 0 CPU 1, SCALE: 1, LIMITS: (, , , ), CURRENT: 39, snmp, , SQL[SELECT COUNT(`sensor_id`) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysCpuSensorTemperature' AND `sensor_index` = '0.1'] SQL RUNTIME[0.00097013s] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '4' AND `sensor_type` = 'F5-BIGIP-SYSTEM-MIB-sysCpuSensorTemperature' AND `sensor_index` = '0.1'] SQL RUNTIME[0.00111198s] SQL[SELECT `attrib_value` FROM `entity_attribs` WHERE `entity_type` = 'sensor' AND `entity_id` = '9' AND `attrib_type` = 'sensor_addition'] SQL RUNTIME[0.00075388s] .] sysBladeVoltageTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -Ih -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysBladeVoltageTable] CMD EXITCODE[0] CMD RUNTIME[0.2932s] STDOUT[ sysBladeVoltageTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] sysBladeTempTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -Ih -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysBladeTempTable] CMD EXITCODE[0] CMD RUNTIME[0.2935s] STDOUT[ sysBladeTempTable = No Such Object available on this agent at this OID ] SNMP STATUS[FALSE] SNMP ERROR[#1000 - Failed response] ] o F5-BIGIP-SYSTEM-MIB sysChassisFanTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysChassisFanTable] CMD EXITCODE[0] CMD RUNTIME[0.2475s] STDOUT[ sysChassisFanIndex.1 = 1 sysChassisFanIndex.2 = 2 sysChassisFanIndex.3 = 3 sysChassisFanStatus.1 = good sysChassisFanStatus.2 = good sysChassisFanStatus.3 = good sysChassisFanSpeed.1 = 11250 sysChassisFanSpeed.2 = 12053 sysChassisFanSpeed.3 = 11637 ] SNMP STATUS[TRUE] Warning, status type name "RlEnvMonState" for MIB "NETGEAR-RADLAN-HWENVIROMENT" also exist in MIB "RADLAN-Physicaldescription-MIB". Type name MUST be unique! Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.1, sysChassisFanStatus.1, F5sysChassisStatus, Chassis Fan, 1, snmp, , fan SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00092292s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00100088s] .Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.2, sysChassisFanStatus.2, F5sysChassisStatus, Chassis Fan, 1, snmp, , fan SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.2' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00087786s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.2' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00099587s] .Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.1.2.1.2.3, sysChassisFanStatus.3, F5sysChassisStatus, Chassis Fan, 1, snmp, , fan SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.3' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00093007s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisFanStatus.3' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00100398s] .] sysChassisPowerSupplyTable [ CMD[/usr/bin/snmpbulkwalk -Cr'100' -v2c -c *** -Pu -OQUsb -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' sysChassisPowerSupplyTable] CMD EXITCODE[0] CMD RUNTIME[0.256s] STDOUT[ sysChassisPowerSupplyIndex.1 = 1 sysChassisPowerSupplyIndex.2 = 2 sysChassisPowerSupplyStatus.1 = good sysChassisPowerSupplyStatus.2 = notpresent ] SNMP STATUS[TRUE] Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.3.2.2.2.1.2.1, sysChassisPowerSupplyStatus.1, F5sysChassisStatus, Chassis Power Supply, 1, snmp, , powersupply SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisPowerSupplyStatus.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00089884s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'F5sysChassisStatus' AND `status_index` = 'sysChassisPowerSupplyStatus.1' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00110292s] .Skipped by 'exclude' event value: , Chassis Power Supply ] sysCmSyncStatusId [ CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUve -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' .1.3.6.1.4.1.3375.2.1.14.1.1.0] CMD EXITCODE[0] CMD RUNTIME[0.2445s] STDOUT[ 3 ] SNMP STATUS[TRUE] Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.14.1.1.0, sysCmSyncStatusId.0, sysCmSyncStatusId, Config Sync, 3, snmp, , other SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'sysCmSyncStatusId' AND `status_index` = 'sysCmSyncStatusId.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00089598s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'sysCmSyncStatusId' AND `status_index` = 'sysCmSyncStatusId.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00105119s] .] sysCmFailoverStatusId [ CMD[/usr/bin/snmpget -v2c -c *** -Pu -OQUve -m F5-BIGIP-SYSTEM-MIB -M /opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp:/opt/observium/mibs/f5 'udp':'my-f5.test.com':'161' .1.3.6.1.4.1.3375.2.1.14.3.1.0] CMD EXITCODE[0] CMD RUNTIME[0.2345s] STDOUT[ 4 ] SNMP STATUS[TRUE] Discover status: my-f5.test.com, .1.3.6.1.4.1.3375.2.1.14.3.1.0, sysCmFailoverStatusId.0, sysCmFailoverStatusId, HA State, 4, snmp, , other SQL[SELECT COUNT(*) FROM `status` WHERE `device_id` = '4' AND `status_type` = 'sysCmFailoverStatusId' AND `status_index` = 'sysCmFailoverStatusId.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00092793s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `status_type` = 'sysCmFailoverStatusId' AND `status_index` = 'sysCmFailoverStatusId.0' AND `poller_type`= 'snmp'] SQL RUNTIME[0.00112081s] .] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'temperature' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00113702s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'humidity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00102687s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'fanspeed' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00113106s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'dewpoint' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096893s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'airflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00139904s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'voltage' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00123096s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'current' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00101900s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'charge' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00098300s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'power' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00100803s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'energy' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096011s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'apower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00095105s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'rpower' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00122404s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'crestfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00097609s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'powerfactor' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096107s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'impedance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096297s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'resistance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096011s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'frequency' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00103498s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'dbm' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00116301s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'snr' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00101590s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'dust' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096607s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'sound' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00097108s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'capacity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00103211s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'load' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00095296s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'runtime' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00102496s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'volume' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00105190s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'waterflow' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00105500s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'pressure' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00105000s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'velocity' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096488s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'illuminance' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00094914s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'wavelength' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096202s] SQL[SELECT * FROM `sensors` WHERE `device_id` = '4' AND `sensor_class` = 'counter' AND `poller_type` = 'snmp' AND `sensor_deleted` = '0'] SQL RUNTIME[0.00096297s] SQL[SELECT * FROM `status` WHERE `device_id` = '4' AND `poller_type` = 'snmp' AND `status_deleted` = '0'] SQL RUNTIME[0.00111389s] o Duration 2.9796s SQL[SELECT `device_state` FROM `devices` WHERE `device_id` = '4';] SQL RUNTIME[0.00063896s] SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='loadbalancer',`last_discovered_timetaken` ='3.0401',`force_discovery` ='0',`device_state` ='a:8:{s:2:\"la\";a:3:{s:4:\"1min\";d:0.080000000000000002;s:4:\"5min\";d:0.080000000000000002;s:5:\"15min\";d:0.070000000000000007;}s:8:\"ucd_load\";d:0.080000000000000002;s:15:\"poller_mod_perf\";a:27:{s:6:\"system\";d:0.68710000000000004;s:2:\"os\";d:2.137;s:7:\"sensors\";d:0.2379;s:6:\"status\";d:0.2059;s:10:\"processors\";d:0.80059999999999998;s:8:\"mempools\";d:1.0065999999999999;s:7:\"storage\";d:0.79500000000000004;s:8:\"netstats\";d:0.76549999999999996;s:6:\"hr-mib\";d:0.10290000000000001;s:7:\"ucd-mib\";d:0.33810000000000001;s:13:\"ipSystemStats\";d:0.1923;s:5:\"ports\";d:2.0061;s:9:\"bgp-peers\";d:0.13200000000000001;s:15:\"printersupplies\";d:0.0014;s:10:\"ucd-diskio\";d:0.0016000000000000001;s:4:\"wifi\";d:0.00029999999999999997;s:10:\"p2p-radios\";d:0.0020999999999999999;s:4:\"ospf\";d:0.26889999999999997;s:3:\"sla\";d:0.0016000000000000001;s:11:\"pseudowires\";d:0.0016000000000000001;s:14:\"mac-accounting\";d:0.0018;s:12:\"loadbalancer\";d:34.2044;s:15:\"entity-physical\";d:0.00040000000000000002;s:12:\"applications\";d:0.0025999999999999999;s:9:\"fdb-table\";d:0.26229999999999998;s:6:\"graphs\";d:0.28649999999999998;s:4:\"oids\";d:0.0018;}s:10:\"ucd_ss_cpu\";a:8:{s:12:\"ssCpuRawUser\";a:1:{s:4:\"perc\";d:9.9078139677038664;}s:12:\"ssCpuRawNice\";a:1:{s:4:\"perc\";d:0.48813113621514065;}s:14:\"ssCpuRawSystem\";a:1:{s:4:\"perc\";d:3.7501245828991898;}s:12:\"ssCpuRawIdle\";a:1:{s:4:\"perc\";d:84.78379484571586;}s:17:\"ssCpuRawInterrupt\";a:1:{s:4:\"perc\";d:0.07122428661751691;}s:15:\"ssCpuRawSoftIRQ\";a:1:{s:4:\"perc\";d:0.097198166254627807;}s:14:\"ssCpuRawKernel\";a:1:{s:4:\"perc\";i:0;}s:12:\"ssCpuRawWait\";a:1:{s:4:\"perc\";d:0.90171301459380737;}}s:7:\"ucd_mem\";a:7:{s:10:\"swap_total\";s:7:\"1048572\";s:10:\"swap_avail\";s:6:\"746772\";s:9:\"mem_total\";s:7:\"4060480\";s:9:\"mem_avail\";s:5:\"70144\";s:10:\"mem_shared\";s:5:\"58792\";s:10:\"mem_buffer\";s:5:\"15244\";s:10:\"mem_cached\";s:6:\"332068\";}s:17:\"poller_ports_perf\";a:1:{s:4:\"vlan\";d:0.65885710716247559;}s:14:\"poller_history\";a:11:{i:1547467382;d:44.771700000000003;i:1547467202;d:50.6721;i:1547467022;d:52.7545;i:1547466843;d:46.936999999999998;i:1547466662;d:48.023299999999999;i:1547466483;d:65.335499999999996;i:1547466302;d:52.323;i:1547466122;d:53.079099999999997;i:1547465942;d:52.8613;i:1547465763;d:53.102400000000003;i:1547465582;d:44.663400000000003;}s:17:\"discovery_history\";a:17:{i:1547467530;d:3.0400999999999998;i:1547467516;d:3.1435;i:1547467458;d:3.5712000000000002;i:1547467425;d:2.9062000000000001;i:1547467356;d:2.5388000000000002;i:1547467311;d:2.5232000000000001;i:1547467267;d:2.8773;i:1547467111;d:3.5666000000000002;i:1547467047;d:2.6227;i:1547466987;d:3.4173;i:1547466792;d:2.8748;i:1547466777;d:2.8237999999999999;i:1547466656;d:2.8338999999999999;i:1547466650;d:2.7930000000000001;i:1547466621;d:3.7042999999999999;i:1547465665;d:2.6111;i:1547465581;d:20.748699999999999;}}' WHERE `device_id` = '4'] SQL RUNTIME[0.05262995s] ##### my-f5.test.com [4] completed discovery modules at 2019-01-14 13:05:33 ##### o Discovery time 3.0401 seconds SQL[DELETE FROM `observium_processes` WHERE `process_pid` = '16035' AND `process_name` = 'discovery.php' AND `device_id` = '4'] SQL RUNTIME[0.04010606s] ##### Finished discovery run at 2019-01-14 13:05:33 ##### ./discovery.php: my-f5.test.com - 1 devices discovered in 3.487 secs SQL[SELECT * FROM `observium_processes` WHERE `process_start` < '1547453130'] SQL RUNTIME[0.00071692s] NOTE, $config['snmp']['hide_auth'] is set to TRUE, snmp community and snmp v3 auth hidden from debug output. o Devices Discovered 1 o Discovery Time 3.487 secs o Memory usage 4MB (peak: 4MB) o MySQL Usage Cell[17/0.023s] Row[25/0.036s] Rows[39/0.066s] Column[0/0s] Update[1/0.053s] Insert[1/0.056s] Delete[1/0.041s] o RRDTool Usage